key: cord-0288130-l8uhbvp1 authors: Sadek, Ibrahim; Abdulrazak, Bessam title: A comparison of three heart rate detection algorithms over ballistocardiogram signals date: 2021-01-22 journal: nan DOI: 10.1016/j.bspc.2021.103017 sha: d058b103277632573c08030e8f720b8108a0a05a doc_id: 288130 cord_uid: l8uhbvp1 Heart rate (HR) detection from ballistocardiogram (BCG) signals is challenging because the signal morphology can vary between and within-subjects. Also, it differs from one sensor to another. Hence, it is essential to evaluate HR detection algorithms across several datasets and under different experimental setups. In this paper, we studied the potential of three HR detection algorithms across four independent BCG datasets. The three algorithms are as follows: the multiresolution analysis of the maximal overlap discrete wavelet transform (MODWT-MRA), continuous wavelet transform (CWT), and template matching (TM). The four datasets were obtained using a microbend fiber optic sensor, a fiber Bragg grating sensor, electromechanical films, and load cells, respectively. The datasets were gathered from: a) 10 patients during a polysomnography study, b) 50 subjects in a sitting position, c) 10 subjects in a sleeping position, and d) 40 subjects in a sleeping position. Overall, CWT with derivative of Gaussian provided superior results compared with the MODWT-MRA, CWT (frequency B-spline), and CWT (Shannon). That said, a BCG template was constructed from DataSet1. Then, it was used for HR detection in the other datasets. The TM method achieved satisfactory results for DataSet2 and DataSet3, but it did not detect the HR of two subjects in DataSet4. The proposed methods were implemented on a Raspberry Pi. As a result, the average time required to analyze a 30-second BCG signal was less than one second for all methods. Yet, the MODWT-MRA had the highest performance with an average time of 0.04 seconds. Remote monitoring of vital signs, i.e., body temperature, heart rate (HR) [1] , blood oxygen saturation [2] , respiratory rate (RR), and blood pressure, has attracted public health attention due to rapidly emerging infectious diseases, e.g., coronavirus disease [3] . Besides, changes in vital signs are critical in assessing the severity and prognosis of epidemic diseases. Specifically, these changes are significant signs of deteriorating patient health and Nonetheless, this is not conceivable in real-life scenarios. The sensor location is another element that can largely affect the signal quality. Ideally, the closer the sensor is to the chest and abdomen region, the better the signal quality. Hence, the sensor's desired location is under the upper part of the body, in which it can be placed under the bed sheet or the mattress. In real-life scenarios, we cannot predict subjects' sleep positions, and thus, unless the bed is covered entirely by pressure sensors, the signal quality can be highly degraded. Still, this arrangement will increase the deployment's cost. Furthermore, the BCG signal morphology can vary from one sensor to another and between and within patients. These restrictions should always be considered when a system is designed for analyzing BCG signals [15, 16] . Fast Fourier transform (FFT), Hilbert transform, template matching, autocorrelation, cepstrum, wavelet transform, and empirical mode decomposition, among others, have been implemented for automatic HR detection from BCG signals [5, 17, 18] . Moreover, convolutional neural networks (CNNs) have been employed to segment the "I-J-K" complexes and detect HR in BCG signals [19] [20] [21] . Although CNNs yielded satisfactory results, the training was performed in a controlled setting with a small sample size, including only healthy individuals. Besides, BCG signals were recorded over a short time, i.e., 35 seconds [20] . Wavelet analysis, in particular, has proved to be a valuable tool in analyzing BCG signals because of its ability to handle nonlinear and nonstationary physiological signals [17, 18] . To our knowledge, most of the proposed approaches were not evaluated across different datasets or under different experimental setups. In other words, the generalization of one method across different datasets or settings is not yet feasible. This problem occurs because BCG signals are not benchmarked, as is the case with electrocardiogram signals. As a result, proposed methods are mainly applied to proprietary data. To this end, this research aims to compare three HR detection algorithms across four independent BCG datasets acquired under different experimental setups. These algorithms include the Maximal Overlap Discrete Wavelet Transform (MODWT), Continuous Wavelet Transform (CWT), and Template Matching (TM). The objective of this comparative study is to examine the efficacy of each method across the various datasets and under different experimental setups. Also, we evaluate whether a BCG template from one dataset can be used to detect HR in the other datasets. The rest of the paper is structured as follows. Section 2 discusses related approaches that use wavelet transform or template matching for HR detection from BCG signals. Section 3 describes the experimental setup and data collection protocols. Also, it outlines the principles of the three proposed methods. Findings and contributions made are presented in Sections 4 and 5. Finally, the paper is concluded in Section 6. The wavelet transform (WT) aims at decomposing the signal into smooth and detail components. Thus, the component (or the sum of multiple components), including the most similar pulse-like peaks, can be adopted to locate the J-peaks of the BCG signal. Table 1 presents a summary of wavelet-based methods used in the literature to detect HR from BCG signals. Zhu et al (2005, 2006) [22, 23] applied the "à trous" WT to raw sensor data acquired via a liquid pressure sensor under a pillow. The signals were gathered from 13 healthy subjects during sleep for about two hours. Motion artifacts caused by head and body movements were reduced by a threshold method using the raw signals' standard deviation (SD). The "Cohen-Daubechies-Feauveau" 9/7 (CDF 9/7) biorthogonal wavelet was selected for designing the decomposition and reconstruction filters. The 4 th and 5 th detail components were realigned in the signal phases, and their amplitudes were summed to estimate the BCG signal. Finally, J-peaks were detected using a modified Pan-Tompkins algorithm [24] after noise reduction with a soft threshold method. Jin et al (2009) [25] employed a translation-invariant WT based on adaptive threshold wavelet shrinkage for signal denoising. The Symlet wavelet of order 8 (sym8) was adopted for detecting cardiac cycles because it was closer in shape to the BCG signal. The signal was collected from a healthy subject, but there was no information on the data acquisition process. Then, J-peaks were detected using a pseudo-period detection approach that can locate the signal's largest swings [26] . Postolache et al (2010) [27] designed a framework for measuring HR from two EMFi sensors embedded in the seat and backrest of a wheelchair. BCG signals were gathered from eight subjects seated in the chair over 15 minutes. At first, signals were denoised using discrete stationary WT combined with a soft threshold method. Secondly, the denoised signals were decomposed via a discrete WT-Daubechies (db5) wavelet function. In addition, the cardiac signal was reconstructed by summing the 8 th , 9 th , and 10 th detail components. At last, a time-domain peak detection algorithm was used to detect J-peaks. A similar approach was introduced by Pino et al (2015) [28] , in which BCG signals were acquired via two EMFi sensors embedded in the seat and backrest of a typical chair. Raw sensor data were collected from 19 subjects in a laboratory for over 1 minute and 35 subjects in a hospital waiting area for over 2 minutes. Daubechies (db6) wavelet function was used for the decomposition, and the cardiac signal was reconstructed by summing the 4 th to 7 th detail components. Jpeaks were detected using a customized peak detector algorithm. Gilaberte et al (2010) [29] proposed to use CWT to detect HR from subjects standing on a bathroom scale. Six subjects participated in the study, and data were recorded over ten seconds in different days and conditions (i.e., before and after meals). Subjects were instructed not to talk or move to eliminate noise. The cardiac signal was located using Daubechies (db10) wavelet function at different scale ranges. The authors suggested that two ranges must be explored in the case of very different HR values. Alvarado-Serrano et al (2016) [30] implemented CWT with B-splines to detect HR using data from subjects in a sitting position. A piezo-electric sensor was fixed to a typical chair seat, and raw sensor data were gathered from seven subjects for about 100 seconds. The 5 th scale of CWT was defined as the optimal scale for HR detection. J-peaks were detected through learning and decision stages. In these stages, several experimental parameters were determined that could limit their use in another dataset. Table 1 Summary of wavelet-based approaches used to detect HR from BCG signals. "CDF": Cohen-Daubechies-Feauveau; "sym": Symlet; "db": Daubechies; "D": detail-component; "s": seconds; "min": minutes. [31] proposed to use a TM approach for BCG beat detection. BCG signals were recorded using three sensors: air-mattress, loadcell, and EMFi-film. An individual BCG template was constructed for each sensor using ensemble averaging of valid BCG cycles centered at J-peak points. Five records of 30-second were gathered for each sensor, and the matching was performed using the correlation coefficient function. Paalasmaa et al (2015) [32] presented a method for detecting interbeat intervals from BCG signals acquired with a piezo-electric sensor. A BCG template was created using a clustering-based method. Then, interbeat intervals were detected via a customized cross correlation-based approach. The BCG template was continually being updated based on the detected interbeat intervals. Raw sensor data were recorded overnight from 40 patients in a sleep clinic and 20 subjects at their homes. Nevertheless, only 46 overnight recordings were used in the study. Cathelain et al (2019) [33] introduced a similar approach to [31] . However, the matching was achieved using dynamic time wrapping. In this study, a Murata SCA11H BCG sensor was deployed, and data were acquired from ten healthy subjects over 20 to 50 minutes long naps. The initial BCG template was updated with the newly detected J-peaks to alleviate the variabilities in the BCG signal shape. were used as a gold-standard to assess the proposed HR detection methods. For more details about the MFOS and dataset, readers are referred to [7] . The second dataset (DataSet2) was collected in a realistic setting by an MFOS from 50 participants sitting in a massage chair (elapsed time: 1.01 ± 0.11 hours). The MFOS was installed on the chair's headrest, and BCG signals were transmitted wirelessly to a computer via Bluetooth. The study aimed to evaluate the participants' stress levels at various time points. The participants underwent a sequence of stress-induced activities, rest (no-activity), and relaxation therapy [35, 36] . The continuity of contact was a significant issue in this study. If the participants had lifted or relocated their heads, we could not have recorded the BCG signals. We manually discarded participants' data with artifacts severe enough to degrade BCG signal quality in light of this issue. Therefore, we could only analyze data from 39 participants. ECG signals were simultaneously recorded, and they were used as a reference for HR detection. The third dataset (DataSet3) was gathered from 10 subjects using a sensor mat combining four fiber Bragg grating (FBG) sensor arrays. Each sensor array consisted of six sensors, and they were set to collect signals at 250Hz. The sensor arrays were placed under the subjects' a) head, b) chest, c) chest and abdomen, and d) under hip. The experiment was split into two phases: 10 minutes of supine sleeping and 10 minutes of side sleeping. The ideal sensor's location was under the chest and abdomen. Similarly, optimal results were obtained by averaging signals from the six sensors in the time domain [37] . As a result, the fused signal was employed for HR detection. The fourth dataset (DataSet4) was recently published by Carlson et al (2020) [34] . The signals were obtained from 40 subjects using: a) four electromechanical films (EMFis) and b) four load cells. The EMFis were placed underneath the mattress, and the load cells were positioned under the bedposts. Overall, 4.5 hours of data were collected. The EMFis and load cells were set to collect data at a sampling rate of 1 kHz. For the EMFis, HR was computed by fusing the four EMFis signals using a pairwise maximum operation. Average fusion was also examined. Nevertheless, the fused signal was distorted, and the main features of a typical BCG signal (i.e., "I-J-K" complexes) were missed. For the load cells, HR was detected by fusing signals from two load cells denoted as "LC2" and "LC3" using a pairwise maximum operation. Across the four datasets, acquired BCG signals were preprocessed to separate motion artifacts and no-activity intervals. The preprocessing step was carried out using a sliding time window of 30-seconds with an overlap of 15-seconds. The standard deviation (SD) of each time window was computed. Then, the median absolute deviation (MAD) of the SDs was calculated. Time windows with SD greater than 2 times the MAD were considered as motion artifacts. Furthermore, time windows with SD less than a fixed value (10 mV) were regarded as noactivity intervals and discarded from further analysis. No-activity implies that no pressure force was applied to the MFOS. The remaining time windows were considered informative signals wherein BCG signals could be extracted. Following the preprocessing step, a bandpass filter was applied to the informative signals (artifact-free) for obtaining BCG signals. The bandpass filter was constructed by cascading high and low pass filters as follows: 1) second-order Chebyshev type I high-pass filter with a maximum ripple of 0.5 dB, and a critical frequency of 2.5Hz followed by 2) fourth-order Chebyshev type I low-pass filter with a maximum ripple of 0.5dB and critical frequency of 5Hz. Unlike DWT, the MODWT skips the downsampling after filtering the signal. The reason is that it gains other features, e.g., invariant to time-shifting, the ability to analyze any time series with arbitrary sample size, and increased resolution at a coarser scale. Besides, it generates a more asymptotically efficient wavelet variance estimator than DWT [38, 39] . MODWT decomposes a signal into a number of details and a single smooth. The details describe variations at a particular time scale, whereas the smooth describes the low-frequency variations. Given a time series of samples, the level 0 MODWT is a transform consisting of 0 + 1 vector that is, � 1 , ⋯ , � 0 and � 0 . All these vectors have a dimension . The vector � comprises wavelet coefficients linked to changes on the scale = 2 −1 , whereas the � 0 comprises the MODWT scaling coefficients linked to averages on the scale 0 = 2 0 [40] . The � and � can be constructed by filtering as follows: Where is the wavelet detail at decomposition , and is the wavelet smooth at decomposition . Figure 3 shows an example of the MODWT multiresolution analysis for a 10-second BCG signal. It can be seen that the 4 th level smooth coefficient (S4) represents the J-Peaks of the BCG signal. We briefly discuss the CWT in the next subsection. Figure 3 MODWT multiresolution analysis for a 10-second BCG signal. Wavelet Biorthogonal 3.9 (bior3.9) with 4 decomposition levels were opted to analyze the BCG signal. The maximum peaks of the 4 th level smooth coefficient (S4) correspond to the J-Peaks. The amplitude was normalized (z-score) for better visualization. Continuous wavelet transform (CWT) is a time-frequency (more correctly, a time-scale) transform that is a useful tool for examining nonstationary signals. CWT is a generalization of the short-time Fourier transform (STFT) commonly used to analyze nonstationary signals at multiple scales [41] . In a similar way to STFT, CWT applies an analysis window, i.e., a wavelet, to extract segments from a signal. In contrast to STFT, the wavelet is not only translated but dilated and contracted to consider the scale of the activity under consideration. The wavelet's dilation and contraction serve two purposes, i.e., increasing the CWT's sensitivity to long-and short-time scale events, respectively. Given a continuous input signal ( ), the CWT can be defined as follows: Where ( ) is the mother wavelet, is a scale, is a shift parameter; ( , ) is a bivariate function obtained by mapping ( ) and a wavelet scaled by at a given time . The localized correlation in time is determined over an integral starting with = and ending duration = + , where is the wavelet's duration. It is noteworthy that short-term events (high-frequency signal components) such as spikes and transients can be determined when the wavelet is contracted ( < 1), whereas long-time events (low-frequency signal components) such as baseline oscillations can be determined when the wavelet is stretched ( > 1) [41, 42] . The result of the CWT can be shown in a graph known as a scalogram. It can be created by estimating the correlation between a signal and wavelets with different scales and then plotting how the correlation of each wavelet changes over a given period [41] . Over the past few decades, template matching (TM) has been one of the most common methods in pattern recognition [43] . This method aims to determine the similarity between a template/prototype signal and a target signal. The main challenge of this method is to choose the prototype and the similarity measure. The prototype (cardiac cycle) was constructed from DataSet1 due to the close contact between the MFOS mat and the participants. However, in DataSet2, BCG signal morphology was primarily affected by the frequent movement of the massage chair. We specified the prototype as follows. Firstly, a human expert selected high-quality BCG segments with a size of 30-seconds (1500-samples) using the BCG signals obtained from the 10 patients. This process was performed using a semi-automatic approach, i.e., motion artifacts were automatically detected using the preprocessing step described in Section 3.1. Then, each 30-second BCG segment was manually verified. The term "high-quality" implies that the segment does not include any signs of motion artifacts. Also, cardiac cycles can be easily identified. Secondly, we divided each 30-second segment into equal slices of 1-second (50-samples) with an overlap of 0.5-second. The redundancy created by the overlapped slices enabled us to accurately detect cardiac cycles, considering the relatively small sampling frequency of the MFOS. Thirdly, we manually classified each 1-second slice into BCG signal and non-BCG signal based on the presence of the "I-J-K" complex using a custom app with a GUI in MATLAB. The non-BCG slices were discarded from our analysis. Finally, the prototype was constructed by an ensemble averaging the valid slices centered at J-peak points ( Figure 5 and Figure 6 ). Figure 5 Block diagram describing how the BCG prototype was created. To this end, the minimum peak distance (MPD) used to detect HR was considered 0.3 seconds, and it was selected using experimental observation. To illustrate, several peak distances were evaluated, i.e., ranging from 0.2 to 0.7 seconds with a step size of 0.05 seconds (Figure 7) . The MPD was appointed by examining the effects of two measures, i.e., precision (Prec) and mean absolute error (MAE), on HR detection across the 10 patients. Detected HR values were classified into correct and incorrect detections for each MPD. Then, Prec was calculated to provide "a rough estimate of how a large portion of the detected HR values are correct," that is, "how correct the detected HR values are" [32, 44, 45] . It was calculated as follows: The average MAE (i.e., between true and correctly predicted HR values) in beats per minute (BPM) tended to increase with increasing the distance. In addition, the average precision tended to decrease with increasing the distance. Therefore, the 0.3-second interval was assigned as an optimal interval to strike a balance between lower MAE (5.02) and higher precision (68.91%). Figure 6 An ensemble averaging of BCG signals. The "I-J-K" represents the ejection phase of the cardiac cycle. For each cardiac cycle, a candidate J-peak was detected by finding the maximum peak of the cross-correlation function (CCF) between the template and the BCG signal. CCF is defined by calculating the correlation coefficients between the samples of the template ( ) and the BCG signal shifted by , ( ( − )) [46] . The formula is as follows: Both signals were supposed to have samples each (50 samples). At last, J-peaks were only deemed to be heartbeats, if the minimum distances between peaks were 0.3 seconds. The HR was computed on a 30-second window and sliding the window by 15 seconds. The time window choice was based on previous studies [7, 36, 47] , taking into account the sampling rate of the sensor (50Hz). Regarding the MODWT-MRA, the Biorthogonal 3.9 (bior3.9) wavelet was appointed to detect cardiac cycles. The bior3.9 wavelet proved to be the most suitable to characterize the profile of cardiac cycles across different wavelets, precisely Daubechies 1 (db1), Symlet 2 (sym2), Coiflets 1 (coif1), and Reverse Biorthogonal 3.1 (rbior3.1) [18] . BCG signals were analyzed using 4 decomposition levels, and the 4 th level smooth coefficient was employed for J-peaks detection [7, 36, 47] . The periodicity of the smooth coefficient reflected the same periodicity as the HR (Figure 3 ). At last, J-peaks were localized using a peak detector. Table 2 Parameters and scales of the CWT for HR detection; is an order-dependent normalization constant, is the spline order, is the bandwidth, and is the center frequency. is an order-dependent normalization constant, is the spline order, is the bandwidth, and is the center frequency. For each wavelet, BCG signals were analyzed at different scales using the scalogram (Figure 4) , and then the scale reflecting the same periodicity as the HR was designated for J-peaks detection [29] . The designated parameters and scales of the three wavelets are given in Table 2 . For the rest of the paper, Gaus2, Fbsp2-1-1, and Shan1.5-1.0 will be used to refer to the CWT wavelets. On the other hand, BCG signals obtained from DataSet1 were used to construct a BCG template (training phase). The created template was then employed to detect HR in the remaining datasets, as outlined in subsection 3.4. The HR value at a time , at which the ℎ maximum occurred, was defined as follows: Where is the time at ℎ local maxima and t n−1 is the time at ( − 1) ℎ local maxima in the designated MODWT coefficient or CWT scale. The proposed methods were implemented using Python 3.8 on a Raspberry Pi 3 Model B (Quad-Core 1.2GHz and 1GB RAM) as an embedded system. The MODWT-MRA method was applied using the "wmtsa-python" library 1 , while CWT-based methods were applied using the "Scaleogram" library 2 . In short, the average time needed to analyze a 30-second BCG signal was less than one second for the 5 methods. Yet, the MODWT-MRA took less time compared to other methods, i.e., 0.04 seconds. Shan1.5-1.0 and Fbsp2-1-1 required more time to analyze a BCG signal, i.e., 0.43 and 0.44 seconds (Table 3 ). This performance was expected because a large number of scales were used, specifically 100. The time required for the TM was 0.12 seconds. The improved performance for the MODWT-MRA occurred because the "wmtsa-python" library is written in Python and Cython. However, "Scaleogram" library uses an adaptive convolution algorithm selection; that is, the scale processing loop switches to FFT-based convolution when the complexity is better in * 2( ). MODWT-MRA is expected to be more efficient for applications that require real-time processing of the data considering its improved performance. Further information about acquiring raw sensor data from the MFOS can be found in the Appendix. This section presents the results of the three proposed methods across the four datasets. For each method, the BPM error between the reference ECG and the measurement device was evaluated separately using the MAE, mean absolute percentage error (MAPE), and root mean square error (RMSE). All figures were generated using Python (Matplotlib, Plotnine, Bokeh, and Seaborn). The BPM error is reported such as "mean (SD)" unless otherwise stated. Table 9 shows all the errors reported for each of the datasets and each of the algorithms used. As presented in Table 4 HR absolute errors for each wavelet method are represented as histograms in Figure 8 . Moreover, Figure 9 shows the Bland-Altman plot of HR for Gaus2 function across DataSet1. The limits of agreement (LoA) were computed as described in [48, 49] given the fact that multiple observations per individual are available. The upper and lower LoA values were 10.95 and -11.17 BPM ( = 0.38, < .001); is the "repeated measures correlation" described in [50] . This particular dataset was challenging because BCG signals were gathered in a noisy environment. The signal quality was affected to a large degree by the massage chair's movement and loss of contact with the MFOS. Table 6 . Table 6 The maximum, minimum, and total values of the precision for the 4 wavelet-based functions (i.e., MODWT-MRA, Gaus2, Fbsp2-1-1, and Shan1.5-1.0) and the template matching approach. The TM method's performance depends mainly on the template and similarity measure, i.e., a cross-correlation in our case. The BCG template was created from DataSet1. Accordingly, the intention was to utilize this template were reasonable, the total Prec, i.e., 72.83% (15%), was not as good as Gaus2 (Table 6 ). Figure 12 Bland-Altman plot of the TM approach across DataSet2. Markers' colors were randomly assigned for each subject. Still, this fairly small Prec value was expected given the fact that the template was generated from a different dataset. Moreover, the BCG signals in DataSet2 were heavily corrupted by head movement artifacts. Figure 12 shows the Bland-Altman plot of HR for the TM approach across DataSet2. The upper and lower LoA values were 12.12 and -10.04 BPM ( = 0.34, < .001). Similarly, it could be seen from the plot the relatively small number of HR points (i.e., Prec) in contrast to Gaus2. Additionally, was 0.38; however, for Gaus2 it was 0.37. Figure 13 shows the HR distribution for Gau2 and TM versus the reference ECG for the second participant across DataSet2. In addition, Figure 14 shows the boxplots with p-values for Gaus2 and TM versus the reference ECG across DataSet2. Figure 13 HR distribution for the reference ECG, Gau2, and TM methods for participant 2 (DataSet2). Time-windows were included in the diagram if they had been evaluated by both methods. Figure 14 Boxplots with p-values for Gaus2 and TM methods vs. the reference ECG across DataSet2. For further checking the effectiveness of the TM approach, we used the BCG template generated from DataSet1 to detect HR in DataSet3. We down-sampled the FBG signals to 50Hz so that cardiac cycles could match the BCG template. As given in Table 7 , reasonable results were obtained, in which the total MAE, MAPE, and RMSE were 3.43 (1.26), 5.51% (2.31%), and 4.58 (1.26), respectively. Figure 16 shows the repeated measures correlation (Rmcorr) plot for HR detection across DataSet3 using the TM method. Across the ten subjects, Rmcorr and p-value were: = 0.39 < .001. Figure 16 Repeated measures correlation (rmcorr) coefficient plot [50] for HR detection across DataSet3 using the TM method. Firstly, BCG signals obtained from EMFis and load cells were down-sampled to 50Hz. Gaus2 seemed to provide information about cardiac cycles more accurately than other wavelets. The total Prec accomplished by Gaus2, i.e., 78.83% (17.84%), was slightly inferior to MODWT-MRA, i.e., 80.22% (19.01%). Nonetheless, Gaus2 generated more favorable results with respect to the error measures (Table 5 ). These results make sense because the scales are discretized more finely than the MODWT. That said, MODWT-MRA requires less time for analyzing a 30-second BCG signal than Gaus2 (Table 3) , which makes it a suitable candidate for realtime analysis. It is important to highlight that our findings for the Gaus2 and TM methods provided accepted overall aggregated results that were less than 10% MAPE. As stated in [51] , an error rate of ±10% can be regarded as an accurate threshold for medical ECG monitors. To this end, preferring one method over the other will depend on the application requirements. To illustrate, TM method produced a little better result in detecting HR than Gaus2 ( Figure 13 and Figure 14 ). Yet, the total Prec was smaller than Gaus2. Thus, the TM approach can be more practical for HR detection in a well-controlled environment in which motion artifacts can be minimized. On the other hand, the Gaus2 method seems less susceptible to motion artifacts. Hence, it can be more practical in real-life situations. Still, selecting an optimal wavelet function and scale requires prior knowledge about the BCG signal morphology. These two parameters will vary from one specific sensor to another. Besides, it should be pointed out that the HR detection results can differ significantly from one scale to another. That is to say, a particular scale or wavelet can only provide adequate results for individual cases while the opposite happens for other cases. A situation like this occurred, for example, with Fbsp2-1-1 in DataSet1 (Section 4.1). As given by Table 7 , the total Prec was acceptable, i.e., 80.88% (14.72%). This Prec value was fairly similar to a previous work in which the fusion was performed in the frequency domain using the cepstrum, and the total Prec reported was 84% [52] . In summary, these results may support the potential of using a BCG template from a particular dataset to detect HR in a different dataset and under different conditions. The three methods described thus far have provided consistent results for HR detection from BCG signals. Moreover, the total Prec values achieved by the three methods were fairly reasonable, considering that BCG signals were recorded in nonrestricted environments; in other words, subjects' movements were allowed. For the EMFis, Gaus2 achieved closer results to the reference ECG than the TM ( Figure 17) . Moreover, the total Prec attained by Gaus2, i.e., 93.65% (16.57%), was better than that of the TM, i.e., 84.08% (20.89%). Rmcorr and p-value were: = 0.65, < .001 and = 0.35, < .001 for Gaus2 and TM, respectively. On the other hand, the TM failed to analyze signals from subjects "X1001" and "X1005" because the signal's morphology was quite different compared to the MFOS. For the load cells, Gaus2 outperformed the TM in a similar way as it had done using the EMFis. Unlike Gaus2, the TM failed to analyze signals from two subjects, i.e., "X1008", "X1040". Rmcorr and p-values were: = 0.66, < .001 and = 0.36, < .001 for Gaus2 and TM, accordingly. The results mentioned above ( Figure 18 ) demonstrate the superiority of Gaus2 for HR detection compared with the TM. Table 8 (Appendix) shows the Rmcorr and LoA achieved by the three methods across the four datasets. The primary objective of this comparative study was to investigate the performance of three HR detection None. Table 9 All the errors (i.e., MAE, MAPE, RMSE, and Prec) reported for each of the datasets (i.e., DataSet1, DataSet2, DataSet3, and DataSet4) and each of the algorithms used (i.e., MODWT-MRA, CWT-Gaus2, CWT-Fbsp2-1-1, CWT-Shan1.5-1.0, TM). CWT-Fbsp2-1-1 CWT-Shan1. 5 The MFOS is integrated into ambient assisted living (AAL) platforms known as UbiSmart [53, 54] and AmI-IoT [55] . The working principle of the MFOS and its integration into the platforms can be found in [7, [53] [54] [55] [56] . In summary, the MFOS is considered as another sensor that contributes to the knowledge base of the AAL platform (e.g., UbiSmart). The MFOS communicator unit is wired to our Gateway ( Figure 19 ). Figure 19 The connection between the MFOS and the RPi, i.e., the Gateway. Voluminous raw data is read and stored on a micro-SD card for a deeper off-line analysis. Simultaneously, the data is preprocessed to generate high-level events, such as bed empty, bed motion, sleep. Currently, it operates on a time window of 10 seconds. For each time window, an event is produced. The events are then sent to the Server as structured sensor data using MQTT protocol over an Internet connection. The Server handles the received structured information (event). The MFOS will appear in the home description interface as available for the association to a house. If confirmed, this association is stored in the knowledge base (KB). Any subsequent events are then inserted into the KB of the associated house, allowing the reasoning engine to be aware of bed occupancy with respect to our ontology ( Figure 20 ). In parallel, the raw data is processed every 5 minutes to extract information about the subject's respiratory effort and heart rate. This information is also inserted into the KB. Figure 20 shows how we can get raw sensor data from the MSOF via a RPi. Figure 20 UbiSmart framework in three sections. The UbiGate, the Server, and the Service Provisioning [57] . Figure 21 An experimental setup for acquiring raw sensor data from the MFOS. The data were obtained by connecting the communicator unit to the GPIO (general-purpose input/output) of the RPi. Then, the Pi is connected to a PC through an SSH connection. The KST 3 plotting tool (implemented on the RPi) was used to display the data in real-time. Bin Altaf, An ECG Processor for the Detection of Eight Cardiac Arrhythmias with Minimum False Alarms A 0.5V PPG-based Heart Rate and Variability Detection System Contactless vital signs measurement system using RGB-thermal image sensors and its clinical screening test on patients with seasonal influenza Vital signs monitoring with wearable sensors in high-risk surgical patients a clinical validation study Ballistocardiogram signal processing: a review Alternative algorithms and devices in sleep apnoea diagnosis A New Approach for Detecting Sleep Apnea Using a Contactless Bed Sensor: Comparison Study Automatic detection of breathing disorder from ballistocardiography signals, Knowledge-Based Syst Computer aided detection of breathing disorder from ballistocardiography signal using convolutional neural network Accurate Detection of Dobutamine-induced Haemodynamic Changes by Kino-Cardiography: A Randomised Double-Blind Placebo-Controlled Validation Study Wearable Sensing Devices for Point of Care Diagnostics Challenges in Collecting Big Data in A Clinical Environment with Vulnerable Population: Lessons Learned from A Study Using A Multi-modal Sensors Platform UNGERLEIDER, Ballistocardiography; an appraisal of technic, physiologic principles, and clinical value Toward Continuous, Noninvasive Assessment of Ventricular Function and Hemodynamics: Wearable Ballistocardiography Bed-embedded heart and respiration rates detection by longitudinal ballistocardiography and pattern recognition Performance Comparison for Ballistocardiogram Peak Detection Methods Nonintrusive heart rate measurement using ballistocardiogram signals: a comparative study, Signal, Image Video Process A Novel Deep Learning based Neural Network for Heartbeat Detection in Ballistocardiograph U-Net Neural Network for Heartbeat Detection in Ballistocardiography Ballistocardiography monitoring system based on optical fiber interferometer aided with heartbeat segmentation algorithm Accurate Determination of Respiratory Rhythm and Pulse Rate Using an Under-Pillow Sensor Based on Wavelet Transformation Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep A real-time QRS detection algorithm A novel heart rate detection algorithm in ballistocardiogram based on wavelet transform, Second Int New methods for precise detection of systolic complexes in the signal acquired from quantitative seismocardiograph Physiological Parameters Measurement Based on Wheelchair Embedded Sensors and Advanced Signal Processing Noninvasive ambulatory measurement system of cardiac activity Heart and respiratory rate detection on a bathroom scale based on the ballistocardiogram and the continuous wavelet transform An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform Automatic ballistocardiogram (BCG) beat detection using a template matching approach Adaptive heartbeat modeling for beat-to-beat heart rate measurement in ballistocardiograms Dynamic Time Warping for Heartbeat Detection in Ballistocardiography Bed-Based Ballistocardiography: Dataset and Ability to Track Cardiovascular Parameters Sensor data quality processing for vital signs with opportunistic ambient sensing Continuous and unconstrained vital signs monitoring with ballistocardiogram sensors in headrest position Automatic heart rate detection from FBG sensors using sensor fusion and enhanced empirical mode decomposition Wavelet analysis of covariance with application to atmospheric time series The Maximal Overlap Discrete WaveletTransform A wavelet analysis of CMB time-ordered data applied to Archeops Chapter 16-wavelets; multiscale activity in physiological signals, Biomed. Signal Image Process Wavelets in biomedical engineering Enhanced Template Matching Using Dynamic Positional Warping for Identification of Specific Patterns in Electroencephalogram Robust inter-beat interval estimation in cardiac vibration signals Sleep stage estimation from bed leg ballistocardiogram sensors Autocorrelation and Cross-Correlation Methods Nonintrusive Vital Signs Monitoring for Sleep Apnea Patients: A Preliminary Study Agreement Between Methods of Measurement with Multiple Observations Per Individual Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study Heart rate estimation from FBG sensors using cepstrum analysis and sensor fusion Novel Unobtrusive Approach for Sleep Monitoring Using Fiber Optics in an Ambient Assisted Living Platform Agile framework for rapid deployment in ambient assisted living environments Privacy and Security of IoT Based Healthcare Systems: Concerns, Solutions, and Recommendations Simplifying Installation and Maintenance of Ambient Intelligent Solutions Toward Large Scale Deployment Including Subser Semant. Web Technol. Internet Things (Workshop ISWC