key: cord-0272609-pry4in7e authors: Thornton, G. M.; Kroeker, E.; Fleck, B. A.; Zhong, L.; Hartling, L. title: The impact of heating, ventilation and air conditioning (HVAC) design features on the transmission of viruses, including SARS-CoV-2: an overview of reviews date: 2021-09-23 journal: nan DOI: 10.1101/2021.09.22.21263515 sha: aaafc4439cb3879105d719417aa548d634188c4c doc_id: 272609 cord_uid: pry4in7e Objective: Given possible airborne transmission of SARS-CoV-2, an overview of reviews was conducted to understand what is already known from the scientific literature about how virus transmission may be affected by heating, ventilation, and air-conditioning (HVAC) design features in the built environment. Methods: Ovid MEDLINE and Compendex were searched from inception to January 2021. Two reviewers independently screened titles and abstracts and full text of potentially relevant reviews, using a priori inclusion criteria. Inclusion criteria were systematic reviews examining effects of HVAC design features on virus transmission. Two reviewers independently assessed methodological quality using AMSTAR2. Results: Searching identified 361 citations, 45 were potentially relevant, and 7 were included. Reviews were published between 2007 and 2021, and included 47 virus studies. Two earlier reviews (2007, 2016) of 21 studies found sufficient evidence that mechanical ventilation (airflow patterns, ventilation rates) plays a role in airborne transmission; however, both found insufficient evidence to quantify minimum mechanical ventilation requirements. One review (2017) of 9 studies examining humidity and indoor air quality found that influenza virus survival was lowest between 40% and 80% relative humidity; authors noted that ventilation rates were a confounding variable. Two reviews (2021) examined mitigation strategies for coronavirus transmission, finding droplet transmission decreased with increasing temperature and relative humidity. One review (2020) identified 14 studies examining coronavirus transmission in air-conditioning systems, finding HVAC systems played a role in virus spread during previous coronavirus outbreaks. One review (2020) examined virus transmission interventions on public ground transportation, finding ventilation and filtration to be effective. Discussion: Seven reviews synthesizing 47 studies demonstrate a role of HVAC in mitigating airborne virus transmission. Ventilation, humidity, temperature, and filtration can play a role in viability and transmission of viruses, including coronaviruses. Recommendations for minimum standards were not possible due to few studies investigating a given HVAC parameter. The 2019 novel coronavirus (SARS-CoV-2) outbreak, first detected in Wuhan, China, was characterized as a pandemic by the World Health Organization (WHO) in March 2020. [1] Fifteen months later (mid-June 2021), the WHO had reported over 177 million cases of the disease (COVID-19) caused by the virus with over 3.8 million deaths worldwide. [2] Throughout the pandemic there have been conflicting views and debate about routes of transmission. [3] [4] [5] [6] While an important mode of transmission is close contact (i.e., contact transmission with an infected person or contaminated surface, or droplet transmission resulting from close proximity to an infected person), airborne transmission has not been ruled out. Several recent reviews of the scientific literature have identified evidence indicating airborne transmission, which could be particularly problematic in confined and/or crowded indoor spaces. [7] [8] [9] Public health recommendations reflect this emerging evidence with advice to maximize ventilation, ensure proper maintenance and functioning of heating, ventilation and air conditioning (HVAC) systems, and increase use of fresh air where possible. [10] Airborne transmission occurs as a result of smaller droplets staying aloft longer due to their small size and therefore travelling further due to air currents. [3] Several possible mechanisms of airborne coronavirus transmission exist including: 1) droplet (bioaerosols) generation by infectious persons with coughing, sneezing, breathing and talking, which remain airborne for a period of hours to days; 2) short-to long-range transport through heating, ventilation and air conditioning (HVAC) systems and subsequent inhalation of droplet nuclei by other people; and 3) airborne transport of bioaerosols to surfaces (or contamination of surfaces by physical contact), followed by resuspension, inhalation or contact with surfaces. [11, 12] Previous research demonstrated that infectious airborne bioaerosols spread to other spaces via HVAC systems. [12, 13] Multiple features within HVAC systems may influence transmission, including ventilation (e.g., ventilation rate, air changes per hour (ACH), airflow pattern, pressurization), filtration (e.g., filter minimum efficiency reporting value (MERV) rating, age, extent of use), ultraviolet (UV) radiation (e.g., UV power, UV dose) and humidity. [12] Understanding the influences of HVAC systems on airborne transmission in the built environment is critical for building scientists to develop effective engineering control strategies to protect occupant health and well-being and to affect timely public health policies. Previous systematic reviews provide a starting point for understanding what is already known from the scientific literature about HVAC systems and airborne transmission of infectious agents. We conducted an overview of reviews to identify and synthesize previous systematic reviews on this topic. Standards recommended by the international Cochrane organization for the conduct of an overview of reviews [14] were followed. The research question guiding this work was: what is the current synthesized evidence about the effects of heating, ventilation and air conditioning (HVAC) design features on virus transmission? A research librarian (GMT) conducted searches in Ovid MEDLINE and Compendex from inception to June 2020, using concepts related to viruses, transmission and HVAC. The search was updated in January 2021. Search strategies appear in Supplemental Material 1. The unfiltered search strategies were peer-reviewed by two librarians (TL, AH) and the filter for systematic reviews in Ovid MEDLINE was provided by a third librarian (LD). The unfiltered search strategies were part of a larger systematic review project which is registered [15] and its protocol is publicly available. [16] Reference lists of included reviews were screened to identify any other relevant reviews. Conference abstracts and preprints retrieved through the searches were screened to determine whether a full peer-reviewed manuscript was published. References were managed in EndNote; duplicate records were removed prior to screening. Two reviewers (GMT, LH) independently screened the titles and abstracts of all citations retrieved from the electronic searches and other sources. Studies were classified as yes, no or maybe. The first stage of screening was completed in Covidence. We retrieved the full text of all studies classified as yes or maybe. The same reviewers independently applied inclusion/exclusion criteria to each full text document and classified studies as include or exclude. Discrepancies were resolved through discussion between the two reviewers. Reasons for excluding studies at the full text stage were documented (Supplemental Material 3). Inclusion and exclusion criteria are detailed in Supplemental Material 2. We planned to include systematic reviews published in English that searched for and included primary research studies examining the effects of HVAC design features on transmission of viruses (or similar agents). The HVAC features of interest were: mechanical ventilation (ventilation rate, air change, air exchange, airflow); filtration (air filtration, filter type, minimum efficiency reporting value (MERV) rating, filter age and/or use, pressure drop, holding capacity, replacement, change frequency); ultraviolet germicidal irradiation, UVGI (power, dose, uniformity of dose, flow rate, bioaerosol inactivation efficiency, location); humidity or relative humidity. Inclusion was staged in two ways. First, our primary interest was viruses; however, we searched broadly for any infectious agent. Given that we identified reviews specific to viruses, we excluded those that focused exclusively on other agents (e.g., bacteria). Second, we were initially interested in systematic reviews defined by the international Cochrane organization as reviews that use a pre-defined, systematic approach and follow standard approaches to search the literature, select studies for inclusion, assess methodological quality of included studies, extract and synthesize/analyze data from the included studies. As we found few systematic reviews meeting these criteria, we included review articles that satisfied specific requirements for methodological approach and objective. For methodological approach requirements, the authors had to search two or more databases, describe inclusion and exclusion criteria, and describe a process for study selection. For objective . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint requirements, the objective of the review had to be related to an HVAC design feature, including ventilation, filtration, ultraviolet radiation, or humidity. Methodological quality of included reviews was assessed using AMSTAR2. [17] AMSTAR2 is a valid and reliable tool containing 16 items about the methodological conduct of a systematic review. [18] Two authors (GMT, LH) independently assessed the included reviews. Discrepancies were resolved through discussion. The following information was extracted from each review: citation information (e.g., authors, year of publication, country of corresponding author); objectives; search strategy; inclusion/exclusion criteria; settings; population characteristics (as applicable); agent studied (e.g., type of virus, bioaerosol, droplet characteristics); HVAC design features studied; number and characteristics of studies relevant to this overview's research question; results (as reported by review authors) and review authors' conclusions relevant to this overview's research question. Our primary outcome was quantitative measures of the association between HVAC design features and virus transmission; however, we extracted any results reported by the review authors that were relevant to our research question. One reviewer (LH) extracted data using a pre-defined form. A second reviewer (EK) verified data. Discrepancies were resolved through discussion and referring to the relevant publication. We anticipated that the included reviews would not have conducted meta-analyses. We planned to present results in tabular and narrative form. Tables were created describing the reviews, their results (including any quantitative data of associations between HVAC features and virus transmission or proxy outcomes) and conclusions, and their methodological quality. A narrative summary of the findings of each review is provided. We only summarize review findings that were relevant to our research question; for example, if the review included studies of ventilation, . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint humidity, etc in the outdoor and indoor environment, we only report on studies specific to the indoor (built) environment. Patients or the public were not involved in the design, or conduct, or reporting, or dissemination plans of our research. The search retrieved 361 citations, of which 45 were considered potentially relevant and 7 met the inclusion criteria ( Figure 1 ). Tables 1 and 2 provide summaries of the included reviews. The reviews varied somewhat in their objectives (e.g., investigate mechanical ventilation, ventilation rates, airflow patterns, effects of humidity, stability of aerosols containing coronaviruses), agents (e.g., coronaviruses, influenza, viruses), and settings (e.g., built environment, healthcare settings, (Table 3 ) which increased the total count to 21. Sixteen studies were epidemiologic, four involved other observational designs, and one was experimental. Three studies had limited and four had no investigation of ventilation rates or airflow. Studies involved a variety of settings: hospital, hospital ward, or health clinic (n=9); aircraft (n=3); nursing home (n=3); school (n=2); high-rise apartments (n=2); offices (n=1); and animal cage (n=1). Viral agents included SARS-CoV-1 (n=7), influenza (n=5), measles (n=4), chicken pox (n=2), rhinovirus (n=1), common cold (n=1), and smallpox (n=1). Overall quality was . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint assessed as good for twelve, average for five, and unsatisfactory for four studies. The researchers convened a panel of experts in medicine, public health, and engineering. They used a modified Delphi approach with final consensus meeting to rate the 'evidentiary threshold' to support their hypothesis, i.e., direct contribution of ventilation to airborne transmission. Among the virus studies, eight were rated as conclusive, while eight were partly conclusive, and five were nonconclusive. Among the eight conclusive studies, two examined ventilation rates showing higher rates of infection for influenza with lower ventilation rates and six demonstrated an association between airflow patterns and transmission of measles (pediatric office suite), chicken pox (hospital), smallpox (hospital), and SARS-CoV-1 (hospital). In all studies the aerosols travelled a "considerable distance" which the reviewers note "seemed to be related to building design" [13,p.12 ] (e.g., placement of heating radiator, room pressure, functional status of return air outlet). None of the virus studies provided data to support "specification and quantification of the minimum ventilation requirements". [13,p.3] Luongo et al [19] examined evidence from epidemiological studies for the association of mechanical ventilation (at least one HVAC parameter) with airborne transmission of infectious agents in buildings. While the authors included 13 English-language studies, 3 were specific to viruses; all studies were observational and were reported between 1996 and 2011 (median year 2004). One study had two papers which increased the total count to 4 ( Table 3 ). All four virus studies were also included Li et al. [13] Settings included nursing home (n=2), office buildings (n=1), and hospitals (n=1). Viruses represented in the studies included influenza (n=2), SARS-CoV-1 (n=1), and rhinovirus (n=1). Review authors did not assess methodological quality but provided a narrative commentary of the strengths and limitations of each study. Two of the four studies found an association between virus incidence rates, self-reported incidence rates, and risk of exposure with HVAC design features. In a retrospective cohort study of a SARS-CoV-1 outbreak in a hospital, authors measured ventilation rates and found that "proximity to index patient associated with transmission".[19,p.668]. Authors of the second study blindly adjusted outdoor air supply dampers in three office buildings and found a significant positive association between average CO2 greater than 100 ppm above background and frequency of rhinovirus detection in . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint air filters. The third study found lower incidence of influenza in newer nursing homes that had 100% outside air delivery (compared to older homes with 30-70% recirculated air) and filtered room supply (compared with no filtration) during one season; however, data collected over five subsequent years, reported in the fourth study, found no clear association. None of the studies quantified minimum ventilation requirements. Derby et al [20] conducted a literature review to assess the effects of low humidity (less than or equal to 40% relative humidity or RH) on comfort, health, and indoor environmental quality. While the review included around 70 papers, 9 papers examined the effects of humidity on the viability or transmission of airborne viruses. Seven studies were experimental (involving laboratory testing), one paper was a re-analysis of data from one of the experimental studies, and one study involved modelling. Most studies focused on influenza, with one study each examining Columbia SK viruses, murine norovirus, and multiple viruses (influenza, vaccinia, Venezuelan equine encephalomyelitis and poliomyelitis). Most studies examined a wide range of relative humidity from approximately 5-25% RH at the lower range to 75-100% RH at the upper range. The absolute humidity was approximately 25 g/m 3 or less in all studies except one (which ranged from 25 to 125 g/m 3 ). Review authors did not assess the methodological quality of the included studies. In terms of virus viability, four studies showed a reduction at mid-range RH (i.e., approximately 50% RH). Review authors further noted that five studies showed that "virus survival exhibited a canonical dip between 40 and 80% RH",[20,p.39] and that in almost all cases decline in survival was correlated with increased length of exposure. Three studies examined influenza transmission. One study showed reduced transmission among guinea pigs at 50% versus 20 to 35% RH; however, the same pattern was not found when the researchers analyzed the data based on absolute humidity. A second study examined transmission via coughing using manikins and found five times more infectious virus at 7-23% RH versus greater than 43% RH. A modelling study of influenza virus transmission via coughing showed that the infectious virus concentration was 2.4 times more at 10% RH versus 90% RH after 10 minutes and the ratio increased over time. They also demonstrated that the effect of humidity related to droplet size: settling of larger droplets and inactivation of smaller droplets (<5 µm) with greater humidity. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint Review authors did not assess the methodological quality of included studies; however, they commented on some limitations. The review authors concluded that "higher temperatures and and SARS-CoV-2 (n=1), and Phi6 (n=1) which is a bacteriophage used as a surrogate for virus. All were laboratory-based experimental studies. Review authors did not assess or comment on the methodological quality of the studies they included. The aerosolized MERS-CoV data from van Doremalen et al [33] was reported in da Silva et al [32] although not extracted by Noorimotlagh et al. [36] A MERS-CoV study found robustness and strong capability to survive at 25°C and 79% RH; [34] this was a shared reference with da Silva et al. [32] While da Silva et al [32] reported the SARS-CoV-2 survival time from van Doremalen et al [35] , Noorimotlagh et al [36] further clarified that the aerosol survival time for SARS-CoV-2 of 3 h was at 40% RH and 21-23°C, and that the . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint stability of SARS-CoV-2 was similar to SARS-CoV-1. [35] The Phi6 study showed highest virus survival at greater than 85% RH and less than 60% RH with significant decrease between 60% RH and 85% RH. [37] At fixed humidity of 75% RH, infectivity decreased two orders of magnitude between 19°C and 25°C. [37] The review authors concluded that "temperature and relative [38] . Li et al [13] and Chirico et al [21] share other related references on SARS-CoV-1 in hospital wards [39, 40] . Similarly, Li et al [13] and Luongo et al [19] share studies on influenza in nursing homes [41, 42] and rhinovirus in offices [43] . Li et al [13] and Chirico et al [21] share two other references regarding SARS-CoV-1 in high-rise apartment complexes [44, 45] . Overall 12 references were shared between the seven included reviews and eight of the shared references were shared with one review, Li et al [13] (Figure 2 ). Table 4 provides the assessments of the methodological quality of the reviews based on AMSTAR2. Three papers described themselves as systematic reviews, two were rapid reviews, one was a broad literature survey, and one was described simply as a review. The majority provided detailed research questions, explained study designs considered for inclusion, used a comprehensive search strategy, described the included studies, discussed heterogeneity of results, and reported potential conflicts of interest. None or few reviews provided an a priori protocol, performed study selection and data extraction in duplicate, provided a list of excluded . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. specifically examined the role of humidity in relation to indoor air quality; the evidence they . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint identified was specific to influenza and showed virus survival was lowest between 40% and 80% RH and survival time decreased with length of exposure to humidity. One of the studies from Noorimotlagh et al [36] indicated that aerosolized SARS-CoV-2 can survive for 3 h at 40% RH and 21-23 °C [35] . In another recent review published in 2021, da Silva et al [32] that allow for isolation of features and control for confounding variables. However, these studies rely on many assumptions that may not hold in real world settings or are specific to an assumed building design or configuration. As well, these studies may isolate one component in the chain of transmission which does not necessarily equate to actual disease (e.g., detection of viral particles vs infectivity vs disease outcomes).[19,20,32] Results from modelling studies need to be considered alongside epidemiological studies. Previous reviews have highlighted many challenges with studying outbreaks: Li et al [13] mentioned the "most inherent limitation in almost all existing investigations is due to the rapid disappearance of airborne evidence of infection, once the infectious period is over."[13,p.14] They proposed as a solution "contemporaneous air-sampling and environmental measurements" [13,p.14] in locations during a patient's illness, which could be extended to locations of high use or occupancy during a pandemic or seasonal epidemics. The strengths of this study include its comprehensiveness and use of methods to avoid bias, such as pre-specification of inclusion/exclusion criteria and involvement of at least two reviewers at all stages. The main limitation stems from the limits of the included reviews. We initially intended to include only systematic reviews that met internationally recognized definitions and methodological expectations. However, we relaxed our criteria given that many reviews did not meet this standard. While most reviews prespecified their research question and conducted a comprehensive search, few conducted study selection and data extraction in duplicate as recommended to avoid bias, and very few assessed the methodological quality or risk of bias of their included studies which is key to determining the validity and certainty of available evidence. We also did not find reviews of all HVAC design features, for example, none of the included reviews examined UVGI (though a recent narrative review has been published in the context of COVID-19 [48] ) and only a small number of studies across the reviews examined filtration. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Based on multi-disciplinary consensus panel: "of the 40 studies, 18 were considered as non-conclusive or not meeting evidentiary threshold to support a direct contributory role of ventilation rate/airflow pattern to the airborne spread of infectious agents, 12 were partly conclusive or met threshold somewhat, 10 were deemed clearly conclusive supporting a direct contribution." (p.5) "There is insufficient data to specify and quantify the minimum ventilation requirements in hospitals, schools, offices, homes and isolation rooms in relation to spread of infectious diseases via the airborne route." (p.2) "There is strong and sufficient evidence to demonstrate the association between ventilation, air movements in buildings and the transmission/spread of infectious diseases such as measles, tuberculosis, chickenpox, influenza, smallpox and SARS." (p.15) Luongo 2016 [19] 13 studies (1988-2013) of which 11 were observational and 2 were intervention studies. Building-related factors (e.g., ventilation rates) were associated with increased measures of illness in 11 studies; one study showed no association and one was inconclusive. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint Figure 2 : Network representing relevant references (grey circles) from the seven included reviews (black circles): 1_Li_2007; 2_Luongo_2016; 3_Derby_2017; 4_Chirico_2020; 5_Zhen_2020, 6_daSilva_2021; 7_Noorimotlagh_2021. Shared references: 1_Li_2007, 2_Luongo_2016 and 4_Chirico_2020 share Wong_2004 1_Li_2007 and 2_Luongo_2016 share Drinka_1996; Drinka 2004; Myatt 2004 1_Li_2007 and 4_Chirico_2020 share Li_2005_a; Li_2005_b; Yu_2004; Yu_2005 4_Chirico_2020 and 6_daSilva_2021 share Kim_2016 6_daSilva_2021 and 7_Noorimotlagh_2021 share vanDoremalen_2013; Pyankov_2018; vanDoremalen_2020 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint Study design Systematic review, i.e., use of "explicit, systematic methods…aimed at minimizing bias" to "identify, appraise and synthesize all the empirical evidence that meets pre-specified eligibility criteria to answer a specific research question". (https://www.cochranelibrary.com/about/about-cochranereviews) We planned a staged process: we would include reviews that are not described as systematic if they searched at least 2 databases and/or were specific to viruses and met all other inclusion criteria.  Primary studies  Commentaries, opinion pieces No restrictions Publication status Published and/or peer-reviewed Unpublished and/or not peer-reviewed HVAC = heating, ventilation, and air conditioning; MERV = minimum efficiency reporting value; UVGI = ultraviolet germicidal irradiation . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Reasons for exclusion . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) preprint The copyright holder for this this version posted September 23, 2021. ; https://doi.org/10.1101/2021.09.22.21263515 doi: medRxiv preprint WHO Director-General's opening remarks at the media briefing on COVID-19 -11 WHO Coronavirus (COVID-19) Dashboard COVID-19 transmission-up in the air It is time to address airborne transmission of coronavirus disease 2019 (COVID-19) Covid-19: What do we know about airborne transmission of SARS-CoV-2? Covid19 has redefined airborne transmission Airborne transmission of SARS-CoV-2 via aerosols Bidirectional association between COVID-19 and the environment: a systematic review A systematic review of possible airborne transmission of the COVID-19 virus (SARS-CoV-2) in the indoor air environment Transmission of influenza A in human beings Indoor hospital air and the impact of ventilation on bioaerosols: a systematic review Role of ventilation in airborne transmission of infectious agents in the built environment -a multidisciplinary systematic review Cochrane handbook for systematic reviews of interventions version 6 The impact of heating, ventilation and air conditioning (HVAC) design features on the transmission of viruses sector/covid-19-guidance-for-staff-in-the-transport-sector 28. National Academies of Sciences, Engineering, and Medicine. A guide for public transportation pandemic planning and response Infection prevention and control of epidemic-and pandemicprone acute respiratory infections in health care: WHO guidelines Advice on the use of masks in the community, during home care and in healthcare settings in the context of the novel coronavirus (COVID-19) outbreak Airborne spread of infectious SARS-CoV-2: moving forward using lessons from SARS-CoV and MERS-CoV Stability of Middle East respiratory syndrome coronavirus (MERS-CoV) under different environmental conditions Survival of aerosolized coronavirus in the ambient air Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 A systematic review of emerging human coronavirus (SARS-CoV-2) outbreak: focus on disinfection methods, environmental survival, and control and prevention strategies Survival of the enveloped virus Phi6 in droplets as a function of relative humidity, absolute humidity, and temperature Cluster of SARS among medical students exposed to single patient Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong Temporal-spatial analysis of severe acute respiratory syndrome among hospital inpatients Report of an outbreak: nursing home architecture and influenza-A attack rates Report of an outbreak: nursing home architecture and influenza-A attack rates: update Detection of airborne rhinovirus and its relation to outdoor air supply in office environments Evidence of airborne transmission of the severe acute respiratory syndrome virus Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E Hospital ventilation and risk for tuberculous infection in Canadian health care workers Laminar flow vs turbulent flow A critical review on ultraviolet disinfection systems against COVID-19 outbreak: applicability, validation, and safety considerations Effect of temperature and relative humidity on survival of airborne Columbia SK group viruses Measles outbreak in a pediatric practice: airborne transmission in an office setting Risk factors and effectiveness of preventive measures against influenza in the community Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong Absolute humidity influences the seasonal persistence and infectivity of human norovirus Delays in the application of out-break control prophylaxis for influenza A in a nursing home Risk of transmission of airborne infection during train commute based on mathematical model An outbreak of airborne nosocomial varicella Airborne micro-organisms: survival tests with four viruses Virus survival as a seasonal factor in influenza and poliomyelitis Lack of SARS transmission among public hospital workers Airborne transmission of chickenpox in a hospital A major outbreak of severe acute respiratory syndrome in Hong Kong Evidence for probable aerosol transmission of SARS-CoV-2 in a poorly ventilated restaurant Influenza virus transmission is dependent on relative humidity and temperature Roles of humidity and temperature in shaping influenza seasonality COVID-19 outbreak associated with air conditioning in restaurant Transmission potential of the novel coronavirus (COVID-19) onboard the diamond Princess Cruises Ship An outbreak of influenza aboard a commercial airliner High humidity leads to loss of infectious influenza virus from simulated coughs Transmission of the severe acute respiratory syndrome on aircraft Indoor transmission of SARS-CoV-2. medRxiv 2020 Airborne transmission of measles in a physician's office Airborne spread of measles in a suburban elementary school Indoor spread of respiratory infection by recirculation of air Airborne transmission of influenza virus infection in mice An airborne outbreak of smallpox in a German hospital and its significance with respect to other recent outbreaks in Europe Transmission routes of Covid-19 virus in the Diamond Princess Cruise ship Dynamics of airborne influenza A viruses indoors and dependence on humidity Relationship between humidity and influenza A viability in droplets and implications for influenza's seasonality Protection by face masks against influenza A(H1N1)pdm09 virus on trans-Pacific passenger aircraft An advanced numerical model for the assessment of airborne transmission of influenza in bus microenvironments Aircraft cabin air recirculation and symptoms of the common cold Supplemental Material 1. Search Strategies for Ovid MEDLINE and Compendex Database: Ovid MEDLINE(R) ALL 1946 to Present Search Strategy: # Searches 1 exp Aerosols/ 2 Air Microbiology/ 3 exp Viruses/ 4 (aerosol or aerosols or bioaerosol or bioaerosols).mp. 5 droplet nuclei.mp 7 (pathogen or pathogens).mp. 8 (virus or viruses or viral or virome).mp. 9 or/1-8 air change rate or air change rates or air changes per hour or air exchange rate or air exchange rates or air exchanges per hour) tw. or ((systematic* or evidence-based or scoping or umbrella) adj3 (review* or overview*)).pt,mp,jw. or meta-analy*.pt,mp. or (metaanaly* or metaanalys* or research-synthesis).tw. or search*.ab. or (hta or technology assessment OR evidence-based OR scoping OR umbrella AND review*OR overview*) WN ST) AND (1884-2021 WN YR)) OR (((systematic* OR evidence-based OR scoping OR umbrella AND review* OR overview*) WN KY)AND (1884-2021 WN YR)) OR (((hta OR technology assessment Aerosols OR Viruses) WN CV)) AND (1884-2020 WN YR)) OR (((aerosol OR aerosols OR bioaerosol OR bioaerosols OR {droplet nuclei} OR infectio* OR pathogen OR pathogens OR virus OR viruses OR viral OR virome ((({Air conditioning} OR {Air filters} OR Filtration OR {Atmospheric humidity} OR HVAC OR Ventilation OR {Ultraviolet radiation}) WN CV)) AND OR (((air condition* OR {air change rate} OR {air change rates} OR {air changes per hour} OR {air exchange rate} OR {air exchange rates} OR {air exchanges per hour} OR airflow OR {airflow} OR HVAC OR filter OR filters OR filtration OR humidity OR ultraviolet ({Indoor air pollution} OR {Disease control}) WN CV)) AND (1884-2020WN YR)) OR ((({indoor air quality} OR indoor environment* OR transmission) WNKY) AND (1884-2020 WN YR))) AND Study design: not a systematic review (narrative review of transmission modes and prevention and control strategies) Study design: not a systematic review (narrative review of relative humidity and airborne transmission of SARS-CoV-2 in indoor environments Study design: not a systematic review (narrative review of viral bioaerosols and nosocomial infections in healthcare settings HVAC: no comparison/quantitative data of HVAC design features Brankston Transmission of influenza A in human beings HVAC: no HVAC design features (focus on route of influenza A transmission in humans) Browne The roles of transportation and transportation hubs in the propagation of influenza and coronaviruses: a systematic review HVAC: no HVAC design features (focus on role of transportation and transportation hubs in transmission of influenza and coronaviruses Carter Can orthodontic care be safely delivered during the COVID-19 pandemic? Recommendations from a literature review Distribution and influencing factors of airborne bacteria in public facilities used by pollution-sensitive population: a meta-analysis Airborne transmission of SARS-CoV-2 via aerosols Patterns of measles transmission among airplane travelers Multizone modeling of strategies to reduce the spread of airborne infectious agents in healthcare facilities The effectiveness of individual and environmental infection control measures in reducing the transmission of Mycobacterium tuberculosis: a systematic review A systematic scoping review of environmental health conditions in penal institutions On the 2-row rule for infectious disease transmission on aircraft Using the systematic review methodology to evaluate factors that influence the persistence of influenza virus in environmental matrices HVAC: examines temperature and humidity but not in context of HVAC and built environment Khalefa 2021 Evidencebased review of safe theatre practice during the COVID-19 pandemic beyond personal protective equipment Influenza transmission on aircraft: a systematic literature review HVAC: no HVAC design features (focus on transmission of influenza aboard aircraft) HVAC: no HVAC design features (focus on in-room air cleaners A systematic scoping review of environmental health conditions and hygiene behaviors in homeless shelters A systematic review of emerging human coronavirus (SARS-CoV-2) outbreak: focus on disinfection methods, environmental survival, and control and prevention strategies HVAC design features Operating room setup: how to improve health care professionals safety during pandemic COVID-19-A quality improvement study A critical review on ultraviolet disinfection systems against COVID-19 outbreak: applicability, validation, and safety considerations Bidirectional association between COVID-19 and the environment: a systematic review Ramos 2020 HVAC: no HVAC design features (focus on ultraviolet-C environment sterilization in hospitals) Salonen Endotoxin levels and contribution factors of endotoxins in resident, school, and office environments -A review Study design: not a systematic review Agent: looks at standards to maintain good air quality, not to remove/manage specific agents Scheuch 2020 Scheuch G. Breathing is enough: for the spread of influenza virus and SARS-CoV-2 by breathing only Airborne transmission and precautions: facts and myths Environmental disinfection against COVID-19 in different areas of health care facilities: a review Which crucial measures do patients need to follow to prevent transmission of COVID-19 in the dental setting? Indoor hospital air and the impact of ventilation on bioaerosols: a systematic review Study design: not a systematic review HVAC: did not examine association of virus transmission and HVAC Teunis Study design: not a systematic review HVAC: did not examine association of virus transmission and HVAC Turkistani Study design: not a systematic review HVAC: general ventilation but not specific HVAC features Tysiak Study design: not a systematic review HVAC: did not examine association of virus transmission and Research status on particulate reduction technology in livestock houses Influence of air conditioning and mechanical ventilation (ACMV) systems on indoor microbial aerosols Accurate quantification of uncertainty in epidemic parameter estimates and predictions using stochastic compartmental models Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Cluster of SARS among medical students exposed to single patient X Ventilation Yang W, Marr LC. Dynamics of airborne influenza A viruses indoors and dependence on humidity Relationship between humidity and influenza A viability in droplets and implications for influenza's seasonality Evidence of airborne transmission of the severe acute respiratory syndrome virus Temporal-spatial analysis of severe acute respiratory syndrome among hospital inpatients Protection by face masks against influenza A(H1N1)pdm09 virus on trans-Pacific passenger aircraft Aircraft cabin air recirculation and symptoms of the common cold We thank Tara Landry and Alison Henry for conducting the peer review of