key: cord-0260439-i8i3ur6l authors: Cann, A. H. C.; Clarke, C. L.; Brown, J. C.; Thomson, T.; Prendecki, M.; Moshe, M.; Badhan, A.; Elliott, P.; Darzi, A.; Riley, S.; Ashby, D.; Willicombe, M.; Kelleher, P.; Randell, P.; Ward, H.; Barclay, W.; Cooke, G. title: SARS-CoV-2 Antibody Lateral Flow Assay for antibody prevalence studies following vaccine roll out: a Diagnostic Accuracy Study date: 2021-07-16 journal: nan DOI: 10.1101/2021.07.14.21260488 sha: 1a8a658af262b5251b145d99db283b1c672219dd doc_id: 260439 cord_uid: i8i3ur6l Background Lateral flow immunoassays (LFIAs) have the potential to deliver affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of SARS-CoV-2 vaccine. Methods This is a prospective diagnostic accuracy study. Setting Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Laboratory analyses were performed across Imperial College London sites and university facilities. Participants Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following SARS-CoV-2 vaccine booster, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination, and 21 day follow up. A total of 186 paired samples were collected. Interventions During the participants visit, capillary blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG were detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. Main outcome measures The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay. Results Using the threshold value for positivity on serological testing of [≥]7.10 BAU/ml, the overall performance of the test produces an estimate of sensitivity of 91.94% (95% CI 85.67% to 96.06%) and specificity of 93.55% (95% CI 84.30% to 98.21%) using the Abbott assay as reference standard. Conclusions Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveys, but does not meet criteria for individual testing. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint NOTE: This preprint reports new research that has not been certified by peer review and should not be used to guide clinical practice. Lateral flow immunoassays (LFIAs) have the potential to deliver affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of SARS-CoV-2 vaccine. This is a prospective diagnostic accuracy study. Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Laboratory analyses were performed across Imperial College London sites and university facilities. Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following SARS-CoV-2 vaccine booster, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination, and 21 day follow up. A total of 186 paired samples were collected. During the participants visit, capillary blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG were detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay. Using the threshold value for positivity on serological testing of ≥ 7.10 BAU/ml, the overall performance of the test produces an estimate of sensitivity of 91.94% (95% CI 85.67% to 96.06%) and specificity of 93.55% (95% CI 84.30% to 98.21%) using the Abbott assay as reference standard. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveys, but does not meet criteria for individual testing. Covid-19 Lateral flow LFIA Antibodies Neutralisation Seroprevalence . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) As vaccination programmes for Covid-19 are rolled out worldwide, population antibody testing is useful in monitoring immune responses to vaccinations, informing discussion and decisions about booster doses, and assessing levels of potential protective immunity in the population (1). Lateral flow immunoassays (LFIAs) have the potential to deliver affordable, large scale testing of individuals and provide rapid results without the support of central laboratories. This approach has been used across England in the REACT2 (REal time Assessment of Community Transmission 2) to estimate the number of infections during the first wave (2), monitor the decline in antibody positivity over time (3) and assess population antibody prevalence following vaccine roll-out. Prior to the scale up of antibody testing for surveillance, extensive clinical and laboratory evaluation of diagnostic accuracy following natural infection was performed on a range of LFIA antibody tests (4, 5) . The test selected (Fortress, Northern Ireland) detects antibody against the spike protein of the virus (contained in all licensed vaccines) and would therefore be expected to detect vaccine induced antibody responses. This study examined the accuracy of the Fortress LFIA device in detecting antibodies in two cohorts of vaccinated individuals and explored the relationship between LFIA results and viral neutralisation. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Methods This was a prospective diagnostic accuracy study conducted between 23 rd December 2020 and 26 th May 2021. Participants were recruited between 9 th June 2021 and 26 th May 2021. 108 renal transplant recipients who were attending clinic 28 days (range -7 to +14) following a second dose of a SARS-CoV-2 vaccine, (either BNT162b2 Pfizer-BioNTech or ChAdOx1 Oxford-AstraZeneca). Participants underwent a capillary blood draw for immediate testing on the LFIA device and, at the same time, gave a venous blood samples for later serology testing. Clinical characteristics were obtained from electronic medical records. All patients provided written informed consent. Participants were supplied with an LFIA testing kit as used in the REACT home testing programme (6) . The LFIA (Fortress, NI) detects IgG and IgM to the S1 protein. Participants were also provided with verbal instructions on how to use the test by a member of the research team, prior to performing self-testing, with support provided where necessary. The LFIA result was assessed independently by two observers. The results were reported by the colour intensity of the IgG band, and documented as either a positive or negative result. Serological assessment was performed on the Abbott Architect SARS-CoV-2 IgG Quant II CMIA which reports a quantitative anti-Spike antibody titre. The threshold value for positivity of 7.10 binding antibody units (BAU)/ml. Participants were recruited between 20 th December 2020 and 31 st January 2021. 39 healthcare workers were consented when attending for first vaccination with BNT162b2 Pfizer-BioNTech. 38 of these participants, had repeat samples taken at 21 days post vaccination and 1 further participant had samples taken at 21 days who had not had day 0 samples. In total there were 40 participants. Data was collected on age and gender. Medical records of participants were not accessed for this cohort. Participants were supported in capillary blood draw for use with the Fortress LFIA devices as described above. Results were reviewed and recorded by the study team. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Spike protein antibodies (anti-S) were detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. At the time of the study, quantitative antibody titres were reported in AU/ml. To allow combination with cohort 1 data, these were converted to BAU/ml by multiplying by 0.142. In addition, for cohort 2, individuals provided blood for assessment of neutralisation assays. The ability of sera to neutralise SARS-CoV-2 virus was assessed by neutralisation assay on Vero cells. Sera were serially diluted in OptiPRO SFM (Life Technologies) and incubated for 1h at room temperature with 100 TCID50/well of SARS-CoV-2/England/IC19/2020 and transferred to 96-well plates preseeded with Vero-E6 cells. Serum dilutions were performed in duplicate. Plates were incubated at 37°C, 5% CO2 for 42 h before fixing cells in 4% PFA. Cells were treated with methanol 0.6% H2O2 and stained for 1h with a 1:3000 dilution of 40143-R019 rabbit mAb to SARS-CoV-2 nucleocapsid protein (Sino Biological). A 1:3000 dilution of sheep anti-rabbit HRP conjugate (Sigma) was then added for 1 h. TMB substrate (Europa Bioproducts) was added and developed for 20 mins before stopping the reaction with 1M HCl. Plates were read at 450nm and 620nm and the concentration of serum needed to reduce virus signal by 50% was calculated to give NT50 values. The primary outcome of the study was sensitivity and specificity of each LFIA in detecting SARS-CoV-2 IgG antibodies. Statistical analyses were performed with MedCalc. Graphical analyses was performed using GraphPad Prism 9.1.2 software. Ethics approvals were sought for each cohort prior to commencement of the study. The study was approved by the Health Research Authority, Research Ethics Committee (Reference: 20/WA/0123). . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint The characteristics of the participants are described in Tables 1 and 2 . The combined results describe both Cohort 1 and Cohort 2 (n=186 samples, Figure 1 ). The median anti-S titre was 229.5 BAU/ml and mean was 1077 BAU/ml. Of those which scored negative on LFIA (n=68), anti S antibodies were detected in 10 samples, of which 7 had anti-S titre levels <10 BAU/ml Using the threshold value for positivity on serological testing of ≥ 7.10 BAU/ml, the overall performance of the test in these combined cohorts (n=186 samples, Figure 1 ) produce an estimate of sensitivity of 91.94% (95% CI 85.67% to 96.06%) and specificity of 93.55% (95% CI 84.30% to 98.21%) using the Abbott Architect assay as reference standard. Neutralisation titres (NT50) were significantly higher in those with positive LFIA compared to those without ( Figure 2A ). Only one LFIA-negative sample had detectable neutralisation assay using a threshold for positivity of (NT50 of 15 with an anti-S antibody titre of 7.8 BAU/ml). For individuals with detectable IgG on LFIA only 2/34 did not have significant evidence of viral neutralisation. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Discussion This study demonstrates that the Fortress LFIA device performs well in detecting IgG antibodies when comparing against a serological assay widely used in NHS services. LFIAs have been a helpful tool the assessment of population antibody prevalence of SARS-CoV-2, and can play a role in informing vaccination strategy going forwards. The Fortress LFIA has been assessed previously for its performance following natural infection (4), though did not meet MHRA criteria for individual use which recommend antibody tests should have a sensitivity of >98% (95% CI 96% to 100%) and specificity of >98% on a minimum of 200 known negative controls (7) . The test has undergone evaluation for home self-testing (6) and has since been used widely in community studies of antibody prevalence in England. The performance of the LFIA in the cohorts of vaccinated individuals here demonstrates slightly higher sensitivity than previously reported for natural infection, though this difference is not significant. This is likely to reflect higher background titres of antibody following vaccination, particularly after second doses, when compared to natural infection in the community at least in the healthcare worker cohort. The LFIA device does not detect very low levels of antibody which may still correlate with protection from severe disease and/ or hospitalisation. However, in the general population, the number of such individuals with low titres following two vaccinations will be low (in contrast to the renal transplant cohort studied here). A small number of LFIA tests appear to produce false positive results (n=4) with absent antibodies when compared to the Abbott assay. This leads to a slightly lower estimate of specificity, although confidence around this is wide and overlapping with previous estimates. Further work will be undertaken to assess alternative laboratory assays, particularly for comparisons at low levels of antibody. There is growing evidence that the presence of neutralising antibodies in sera is highly predictive of immune protection from symptomatic Covid-19 disease (8, 9) . Although it could be argued that the LFIA is a relatively insensitive assay for detecting total Spike specific antibody, the threshold antibody titre required for a positive score is close to the level at which neutralizing antibody can be reliably measured (Figure 2a ). This suggests that antibody positivity on the LFIA may give some indication of protection from symptomatic disease and thus could be useful to measure any waning of vaccine induced immunity in different populations that might indicate requirement for administration of booster doses. In terms of study limitations it is important to note that, although the LFIAs were self-tested in the clinic or vaccination centre, participants had access to support from trained healthcare professionals when required. This does not fully replicate the 'real-world' application of LFIAs where users will be following a detailed guide in their own homes. Furthermore, the patient cohort includes healthcare workers and as such may demonstrate a greater affinity for self-testing than members of the general . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint population. However, the primary purpose of this study was to evaluate the diagnostics accuracy of the test. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Table 2 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 16, 2021. ; https://doi.org/10.1101/2021.07.14.21260488 doi: medRxiv preprint Population (Antibody) Testing for COVID-19-Technical Challenges, Application and Relevance, an English Perspective. Vaccines (Basel) Antibody prevalence for SARS-CoV-2 in England following first peak of the pandemic: REACT2 study in 100,000 adults. bioRxiv Declining prevalence of antibody positivity to SARS-CoV-2: a community study of 365,000 adults. Cold Spring Harbor Laboratory SARS-CoV-2 lateral flow assays for possible use in national covid-19 seroprevalence surveys (React 2): diagnostic accuracy study Clinical and laboratory evaluation of SARS-CoV-2 lateral flow assays for use in a national COVID-19 seroprevalence survey Usability and acceptability of home-based self-testing for SARS-CoV-2 antibodies for population surveillance Target product profile antibody tests to help determine if people have immunity to SARS-CoV-2 Evidence for antibody as a protective correlate for COVID-19 vaccines Neutralizing antibody levels are highly predictive of immune protection from symptomatic SARS-CoV-2 infection