key: cord-0256616-y1eucs9j authors: Denpetkul, Thammanitchpol; Sittipunsakda, Oranoot; Pumkaew, Monchai; Mongkolsuk, Skorn; Sirikanchana, Kwanrawee title: Effects of face masks and ventilation on the risk of SARS-CoV-2 respiratory transmission in public toilets: a quantitative microbial risk assessment date: 2021-08-22 journal: bioRxiv DOI: 10.1101/2021.08.21.457245 sha: ddcd425e8d6367bd5a494ec110560924572845cb doc_id: 256616 cord_uid: y1eucs9j Public toilets could increase the risk of COVID-19 infection via airborne transmission; however, related research is limited. We aimed to estimate SARS-CoV-2 infection risk through respiratory transmission using a quantitative microbial risk assessment framework by retrieving SARS-CoV-2 concentrations from the swab tests of 251 Thai patients. Three virus-generating scenarios were investigated: an infector breathing, breathing with a cough, and breathing with a sneeze. Infection risk (97.5th percentile) was as high as 10−3 with breathing and increased to 10−1 with a cough or sneeze, thus all higher than the risk benchmark of 5 × 10−5 per event. No significant gender differences for toilet users (receptors) were noted. The highest risk scenario of breathing and a sneeze was further evaluated for risk mitigation measures. Risk mitigation to lower than the benchmark succeeded only when the infector and receptor simultaneously wore an N95 respirator or surgical mask and when the receptor wore an N95 respirator and the infector wore a denim fabric mask. Ventilation up to 20 air changes per hour (ACH), beyond the 12-ACH suggested by the WHO, did not mitigate risk. Virus concentration, volume of expelled droplets, and receptor dwell time were identified as the main contributors to transmission risk. Highlights - The use of public toilets poses a risk of SARS-CoV-2 respiratory transmission - Highest risks generated in the order of sneezing, coughing, and breathing - No gender differences in risk by counteracting dwell times and inhalation rates - Ventilation did not reduce risk even at 20 ACH, beyond the WHO-recommended value - N95 and surgical masks offer the most effective risk mitigation to toilet users Graphical abstract The coronavirus disease 2019 pandemic has affected the global population since its (Sherchan, Shahin, et al., 2020) , which ranged from 125 4.4 × 10 -1 to 6.4 × 10 8 gene copies (gc)/μL. The SARS-CoV-2 concentrations (A) were fitted with a triangular distribution as shown in Table S1 . To convert the virus concentrations from gc to an 127 infectious plaque-forming unit (PFU), the ratios of the PFU/gc (R) of SARS-CoV-2 between 1:100 128 and 1:1000 with a uniform distribution were applied (Pitol & Julian, 2021) . a 20°C temperature, and no direct sunlight, an average SARS-CoV-2 inactivation rate of 0.008 136 (min -1 ) was applied (Schuit, Ratnesar-Shumate, et al., 2020) . We assumed that the virus particles 137 were released continually during the time the infector spent in the toilet cubicle (infector's dwell 138 time = t1 minutes). The dwell times for men and women, which were in line with those indicated 139 in an airport study (250 men and 237 women), were fitted with a log-normal distribution (Table 140 S1) (Gwynne, Hunt, et al., 2019) . The remaining infectious virus concentrations generated by the 141 infector after leaving the toilet (Ct1) were calculated according to Eq. 2 by integrating Eq. 1 with 142 no initial virus particles (C = 0). The inhalation rates (qin) following the uniform distribution ranged 143 between 8.36 and 19.74 L/min for men and 6.4 and 13.78 L/min for women (Brochu, Ducré-144 Robitaille, et al., 2006) . The additional concentrations of infectious SARS-CoV-2 expelled by 145 coughing (Cco) and sneezing (Csn) were calculated using Eqs. 3 and 4, respectively. The volumetric 146 flow of droplets from an infector's exhalation (qbr) ranged from 5 × 10 -9 to 6 × 10 -6 L/min 147 (Schijven, Vermeulen, et al., 2021) . In addition, the volume of aerosol droplets expelled per cough 148 (Vco) and per sneeze (Vsn) was set according to the literature (Schijven, Vermeulen, et al., 2021) . However, the size of the droplets played an important role in their activity. The larger droplets 150 deposited quickly, whereas the smaller droplets (aerosols) could remain suspended in the air for a 151 longer period. Thus, the volumetric ratios of aerosols to total droplets expelled (F) were considered 152 using a droplet size 70 μm based on the size distribution of droplets in the literature for breathing 153 (Fabian, Brain, et al., 2011 ), coughing (Duguid, 1946 Han, Weng, et al., 2013; Loudon and 154 Roberts, 1967) and sneezing (Duguid, 1946; Han, Weng, et al., 2013) (Table S1) . Eq. 2 Virus levels accessible to a receptor 176 Because no input source of virus (no infector) was present, the term of flow in through a system 177 boundary was discarded. To solve Eq. 5, the infectious virus concentrations the receptor (Ct2) was 178 exposed to during the receptor's dwell time t2 were calculated from Eq. 6. In this study, we 179 assumed that after the infector exited the cubicle, the receptor immediately entered the cubicle. The initial concentrations (C0) based on three scenarios (i.e., breathing only, breathing with a 181 cough, and breathing with a sneeze [Eqs. 7-9]) were therefore incorporated into Eq. 6. Given C0 based on the following specific scenarios: Breathing only: Breathing with a cough: C0 = Ct1 + Cco Eq. 8 The virus doses (d) that would be inhaled by a receptor were calculated by incorporating the 193 inhalation rate (qin) with a definite integral of the infectious virus concentration-time function (Ct2). The limits of integration were set from t = 0 to the receptor's dwell time (t2) (Eqs. 10.1-10.2). The 195 initial concentrations (C0) also followed Eqs. 7-9 in line with the desired scenarios. where Pevent is the probability of infection per event (probability), and k is the optimal dose 209 response function value of 4.1 × 10 2 , which is equivalent to the chance that a single pathogen 210 would initiate an infection response (Watanabe, Bartrand, et al., 2010) . To estimate the Pevent for a receptor exposed to SARS-CoV-2, the data from the previous steps Whiley, Keerthirathne, et al., 2020) . We also observed an at least 90% (1-284 log) reduction in risk when an infector wore a denim fabric mask. In a scenario with an infector breathing with a sneeze, the infection risk could be further reduced 288 if both the infector and receptor wear masks (Table S3 ). The receptor's gender did not affect the 289 receptor's risk much in any of the conditions. The risks to a female receptor are illustrated in Figure 290 4. When a receptor wore an N95 respirator, the 97.5th percentile infection risk was reduced to Single measure: ventilation 305 The effects of ventilation (0-20 ACH) were characterized for three virus-generating scenarios: 306 infector breathing, breathing with a cough, and breathing with a sneeze (Table S4 ). The breathing 307 with a sneeze scenario delivered the highest risk, and this worst-case condition was therefore 308 further assessed to determine the effects of ventilation using a representative female receptor 309 ( Figure 5 ). The results showed that increasing ACH did not significantly mitigate the risk of The additional measure of mask wearing was further investigated for its combined effectiveness 325 in mitigating SARS-CoV-2 transmission risk when used simultaneously with increased 326 ventilation. In the virus-generating scenario with an infector breathing with a sneeze, mask wearing 327 by both the infector and receptor was assessed using ventilation of 10, 12, and 20 ACH ( Figure 6 ). When compared with no ACH (Figure 4) , ventilation across all ACH values did not reduce the WHO (2020b) Coronavirus disease (COVID-19) advice for the public: When and how to use masks WHO (2021) Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 World Health Organization