key: cord-0206400-xpz4ewyh authors: D'Alessandro, V.; Falone, M.; Giammichele, L.; Ricci, R. title: Eulerian-Lagrangian modelling of bio-aerosols irradiated by UV-C light in relation to SARS-CoV-2 transmission date: 2020-11-30 journal: nan DOI: nan sha: 60163e28a8f616b6cc447fd359fe2de22f45e87c doc_id: 206400 cord_uid: xpz4ewyh It is well known that several viruses, as well as SARS-CoV-2, can be transmitted through airborne diffusion of saliva micro-droplets. For this reason many reserach groups have been devoted their efforts in order to gain new insight into the transport of fluids and particles originted from human respiratory tracts. This paper aims to provide a contribution to the numerical modelling of bio-aerosols. In particular, the well-known problem around the safety distance to be held for avoiding virus transmission in the absence of external wind is further investigated. Thus, new indexes capable of evaluating the contamination risk are introduced and the possibility to inactivate virus particles by means of an external UV-C radiation source is studied. For this purpose, a new model which takes into account biological inactivation deriving from UV-C exposure in a Eulerian-Lagrangian framework is presented. As largely reported in the open literature, several viruses, as well as SARS-CoV-2, can be transmitted through airborne diffusion of saliva micro-droplets 1 too small to be seen with the naked eye. Typical infection mechanisms are the following: (i) direct transfer of large droplets expelled at high momentum to the receiver's conjunctiva, mouth, or nose; (ii) physical contact with droplets deposited on the surface and subsequent absorption to the nasal mucosa of the receiver; (iii) inhalation by the recipient of respiratory ejected aerosolised droplet nuclei 2 . For this reason, many countries in the world have imposed variable social distances to be kept between persons. This restriction has been adopted since the safety distance must be guaranteed in order to allow the most elevate number of the droplets to fall down and reach the floor, or even evaporate, after their emission from a mouth or nose. Hence, it is straightforward to understand that the correct and rigorous study of saliva droplets dynamics, involving all the relevant biological and physical phenomena, is the key ingredient to determine the guidelines on social distancing, face masks wearing as well as the implementation of new practices in the daily social life. It is also worth noting that the physical phenomena involved in the droplets transmission process are very complex. Indeed, after their emission, micro-droplets travel as results of their inertia and their aerodynamic interaction with air. Moreover, the mass of the droplet can vary due to evaporation which is strictly connected to air temperature and relative humidity. After SARS epidemic, that started at end of 2002, several studies about airborne droplets transmission have been published in medical and non-medical journals. As already introduced, both computational and experimental models have been employed by investigators with particular emphasis on indoor conditions 3 . Some research groups have carried on chamber experiments. However, an essential disadvantage of a) Electronic mail: v.dalessandro@univpm.it. this kind of approaches is that traditional measurements are too discrete, i.e. only a few points can be investigated at the same time. Although laser-based techniques, such as Particle Image Velocimetry (PIV), allow measuring 2D or even 3D velocity fields, they cannot provide a quantitative evaluation of the cross-infection risks 4 . Besides, flow and concentration sensors can produce significant disturbances for droplet's transport inside the mouth/nose zone. Lastly, it is worth noting that similar apparatuses are expensive. Numerical modelling can be considered a valid alternative to overcome these limitations 5 . Flow fields and droplet dynamics can be computed with a very high temporal resolution, far less than the scale of the human breathing activities. Moreover, computer simulations have more considerable flexibility than experimental investigations. However, an important issue for CFD simulations is the obtained accuracy, which is influenced by geometrical simplifications as well as the failure of adopted models 5 . After unprecedented COVID-19 pandemic several research groups have been devoted their efforts in order to gain new insight into the transport of fluids and particles emanating from human respiratory tracts. With this work we want to contribute to this emerging and important research field in the numerical modelling context. In this area we can find the Vuorinen et al. 6 paper which discuss the physical processes related to the aerosolisation of the exhaled droplets by means of Large-Eddy-Simulation (LES). A similar approach was used by Pendar and Pascoa 7 which focused their effort on the development of reliable model for the emission of saliva droplets during coughing and sneezing. Differently, Dbouk and Drikakis 8-10 developed a Eulerian-Lagrangian model based on Reynolds-Averaged Navier-Stokes (RANS) equations for the simulation of human cough; the impact of face masks and weather conditions on the droplet evaporation phenomenon were studied. Also Busco et al. 11 adopted RANS equations to model the carrier fluid in sneezing and asymptomatic conditions. In Abuhegazy et al. 12 a RANS based Eulerian-Lagrangian model of bio-aerosol transport in a classroom, with relevance to COVID-19, is presented. Lastly, Li et al. 13 presented a CFD model for droplets evapo-ration and transport in tropical outdoor environment. In this paper, a new computational model, relying on the well established OpenFOAM library 14 , for the evaluation of saliva droplets' dynamics during coughing is presented. Starting from the work published in the more relevant papers (above briefly discussed), the authors intend to provide CFD practitioners with several crucial data about case settings. Also, two new indexes are introduced in order to evaluate contamination risk. Lastly, a focus on the possibility to reduce SARS-CoV-2 transmission potential by means of UV-C radiation is shown. This topic was already investigated by Buchan et al. 15 . In the cited paper, the UV-C effect was assessed considering saliva droplets in a dilute solution with air. On the contrary, the present work aims to introduce an approach capable of including the biological inactivation related to UV-C field in an Eulerian-Lagrangian framework. This paper is organised as follows: the governing equations are presented in Section II, while the numerical discretisation techniques are discussed in Section III. Numerical results are shown in Section IV. Lastly, Section V contains the conclusions. Numerical simulations are developed using an Eulerian-Lagrangian framework in which Eulerian approach is applied to the atmospheric air. The Lagrangian reference frame is adopted for dispersed droplets generated by breathing. For Eulerian phase compressible RANS equations are used: where ρ,ũ i , p,T andỸ k denote density, velocity component in x i direction, pressure, temperature and chemical specie k mass fraction.Ẽ andH are, respectively, the total internal energy and entalpy. Note that the overbar and the tilde are filtering operators which are introduced for unweighted and densityweighted averages. The unclosed terms reported in eq. 1 are handled as follows: in eq. 2 the symbol c p represents the specific heat at constant pressure and µ is the viscosity. Pr and Sc k are molecular Prandtl and Schmidt numbers, the lower-script t indicates the turbulent version of the previous dimensionless groups. The stress tensorτ i j is evaluated as follows: where k is the average turbulent kinetic energy andS i j the strainrate tensor. Turbulence modelling is performed using standard SST k-ω, developed by Menter 16 , not described here for compactness. Polynomial equation of state was adopted and polynomial correlations were used for thermophysical properties. The source terms s m , s m,i , s e and s Y k correspond to coupling between Lagrangian and Eulerian phases with respect to mass, momentum, energy and species, respectively. The particlesource-in-cell (PSI-Cell) method 17 for source terms manipulation is adopted. Saliva droplets are tracked using a Lagrangian frame throughout the computational domain. It is crucial to put in evidence that, within OpenFOAM Lagrangian libraries, for efficiency reasons, the concept of computational parcel is adopted. The droplets are organised in groups and each parcel represents the centre of mass of a small cloud of droplets having the same properties. Assuming non-collisional spherical parcels, position and velocity are the results of the trajectory and momentum equations: with parcel velocity u P,i , mass m P,i and position x P,i . The forces acting on the generic i-th parcel in eq. 5, are identifiable with two contributions: gravity force ( F G P,i ) and aerodynamic drag force (F D P,i ). Gravity force takes also into account buoyancy in the following way: where ρ P is the density of the generic element of the discrete phase. The aerodynamic drag force, F D P,i , is : the drag coefficient, C D , is evaluated from a correlation based on Putnam 18 paper being then D P the particles' diameter. Additional forces including the following components: pressure, virtual mass, Basset and Brownian, are not included as done by other authors [11] [12] [13] . As a matter of the fact, the particles considered in the present work are sufficiently small to neglect pressure and virtual mass forces and sufficiently large to neglect Brownian force 12, 19, 20 . This evidence held true also in the preliminary computations carried out in this research. The mass conservation equation reads: where the evaporation term,ṁ ev P,i , is governed by the diffusive flux of vapor and the mass transfer coefficient is obtained from the well established Ranz-Marshall correlation 21 . Lastly, the parcel temperature, T P,i , is obtained through the analytic solution of the energy equation: In eq. 9 the convective heat transfer coefficient, h, is obtained from the Ranz-Marshall correlation 21 for Nu number;Q ev is the term including the heat transfer between continuous and discrete phase due to droplets evaporation. The Rosin-Rammler distribution 22 is used for representing initial parcels' diameter: in eq. 10 we fix n = 8 and D p = 80 µm as in Dbouk and Drikakis 9 who performed a fit of Xie et al. 23 experimental data regarding human cough. The minimum diameter of the injected parcels is 10 µm, while the maximum one is 280 µm. The present work shows a new model able to take into account the presence of virus/bacterial particles in a bio-aerosol and evaluate their biological inactivation produced by an external UV-C field. This is a complex multi-physics problem, and it was addressed in the available literature by solving a transport equation for virus concentration 15, 24, 25 . Similar approaches can be considered appropriate for handling dilute solutions, but they are not suitable to investigate the interaction of UV-C light with a cloud of saliva droplets produced during cough or sneeze. In the here described approach the number of active particles in each parcel, N a,i , is estimated starting from the number of particles grouped inside the parcel itself, N p,i , as follows: where In eq. 12 the term I a,i is the number of particles inactivated by UV-C radiation in the parcel focusing on the point x P,i ; the integer parameter, N ts , represents the current time-step index. It is important to remark that the inactivation coefficient, F a,i , is derived from first-order Chick-Watson kinetics: In eq. 13 N (t) and N 0 represent the number of active particles at the generic time instant t and t = 0, respectively. Differently, Z is a susceptibility constant for the microorganism and E p is the mean irradiance of the UV-C field. In this research work, we fix Z = 8.5281·10 −2 m 2 /J which is the average experimental value 26 obtained for a UV-C light (λ = 254 nm) irradiating SARS-CoV-2. As regards E p , its estimation is achieved by means of the thermal radiation view factors method 27 . This technique was chosen for its capability in well describing the intensity field due to cylindrical UV-lamps 28 . The fraction of the total radiation intensity emitted, that is collected by a parcel perpendicular to the lamp axis and located in correspondence of its edge, is given by: The parameters in eq. 14 are based on the length of the lamp axis, l, its radius, r and the distance from the lamp, d. They are calculated as follows: The total view factor, F tot , is actually adopted to evaluate the UV-C irradiance field reaching a parcel. For points located between lamp edges, F tot is given by the superposition of two different contributions: It is worth noting that l 1 and l 2 are segments deriving from lamp splitting in correspondence of the parcel position. Hence, F(l 1 ) and F(l 2 ) are the results of the application of eq. 14 to the lamp portions. Differently, for parcels located beyond or before the lamp ends, a "ghost" length, l g , is con-sidered. This length is the the axial distance between parcel and lamp edge. In this case, the total view factor is calculated subtracting the ghost portion contribution as follow: Lastly, F tot is used to evaluate the UV-C field intensity on each parcel present in the domain as a function of its distance from the lamp axis: in the above equation W l is the total power of the lamp. The governing equations solution relies on the OpenFOAM library. Thus, the unstructured, colocated, cell-centred finite volume method was adopted for the space discretisation. An implicit, three levels, second-order scheme was used for the time-integration together with the dynamic adjustable time stepping technique for guaranteeing a local Courant (Co) number less than a user-defined value (Co max ). The interpolation of convective fluxes is treated by the linear upwind scheme, whereas diffusive terms are discretised by a standard second-order central scheme. Moreover, the pressure velocity-coupling is handled through PISO procedure 29 . For the linear solvers a preconditioned conjugate gradient method (PCG) with a diagonal incomplete-Cholesky preconditioner was used to solve pressure equation. A preconditioned bi-conjugate gradient method (PBiCG) with the DILU preconditioner was adopted instead for the remaining equations. In particular, a local accuracy of 10 −7 was established for the pressure, whereas other linear systems were considered as converged when the residuals reached the machine precision. In the present work, a 3D computational domain was considered as shown in Fig. 1 . It consists of an air volume starting from the mouth-print of a standing coughing person. A length L = 4 m, a width W = 1 m and a height H = 3 m were adopted, in accordance with Dbouk and Drikakis 8 . The mouth print is approximated as rectangular, having a length of l m = 0.04 m and a total area A m = 2 · 10 −4 m 2 . The reference frame origin, O = (0, 0, 0), is fixed in the same plane where the mouth print is placed, see Fig. 1 and Fig. 2 . In particular, O is in the middle of the previous face in correspondence with the intersection of the domain bottom side. x-axis is aligned with bio-aerosol propagation direction; y-axis represents transverse direction, while z-axis is the vertical direction. The mouth-print centre, P m , was placed in the same position selected by Dbouk and Drikakis 8 : P m = (0, 0, 1.63). Fully-structured meshes were built in order to discretise the domain. A suite of three different grids named S 1, S 2 and S 3 was generated using, for all the cases, 160 cells for mouth discretization. Besides, mesh elements size grading was applied so as to achieve a proper discretisation in the droplets' emission and transport areas (Fig. 2) . The height of the first cell next to the ground, z c , was set at 10 −3 m. Other grids details are collected in Tab. I. A stepped velocity inlet at the mouth boundary, with injection of parcels, was applied to mimic the human cough over 0.12 s. Velocity inlet value was deduced on the base of measurements carried on by Scharfman et al. 30 , and it is equal to 8.5 m/s in the streamwise direction both for carrier fluid and injected parcels. In the same boundary turbulence intensity, Tu, is fixed at 15% and the mixing length equal to 7 · 10 −3 . Furthermore, the initial total mass of saliva droplets laden into the domain is 7.7 mg according to the experimental measurements performed by Xie et al. 23 and CFD simulations of Dbouk and Drikakis 8 . Saliva is, in general, a complex fluid but, following Van Der Reijden et al. 31 , it could be approximated as water. For this reason, the impact of the UV-C field on the parcels' temperature is neglected since UV-C water absorptivity is extremely low. The remaining part of the yz plane at x = 0 m is such that all the variables have a null gradient through it. The bottom side of the domain, i.e. the ground, is modelled as a standard wall. Symmetry condition is imposed on lateral boundaries: y = ±0.5 m. On the other hand, zero gradient condition is set for all variables at the domain top with the exception of the pressure. In this case, the pressure is reduced of its hydrostatic level. The y-z plane at x = 4 m is managed as a physical outflow. However, the pres-sure is imposed to decrease linearly, starting from atmospheric pressure level at z = 0. The initial temperature of the carrier fluid is 20 • C with relative humidity fixed at 50%. The ground is at 25 • C, while the air and droplets ejected by human mouth are at 34 • C. The initial mass fraction composition of the Eulerian phase is: 0.991 dry-air and 0.009 water-vapor as in Dbouk and Drikakis 8 . The hypothesis of injection of saturated moist-air from the mouth is also taken into account in the present work. The estimated maximum Weber number is smaller than the critical one 32 , this is the reason why any secondary breakup model is introduced in the following computations. It is very important to put in evidence that previous initial conditions are not adopted for our full computations. Indeed, they are used as initial conditions of a preliminary simulation aimed to generate adequate initial fields the full runs. In this simulation, the transient condition for mouth print boundary is not employed and treated like the remaining part of the x = 0 plane. The preliminary simulations stage is considered completed when a physical time of 15 s is reached. It is worth emphasising that, after this precursor, turbulent variables are initialised, and the hydrostatic pressure field, not available in the previously described situation associated to an imposed uniform field, is obtained. Cloud evolution is also strongly influenced as represented in Fig. 3 . Indeed, the cloud centre of mass position (defined in the next Section) in time completely changes when initialised fields are employed. The present section shows the obtained numerical results referred to the bio-aerosol produced during coughing as cloud. Several cloud characteristics will be calculated and considered in order to investigate its diffusion and interaction with artificial UV-C light, i.e. (i) cloud centre of mass; (ii) streamwise liquid penetration length; (iii) fraction of particles present in a reference volume; (iv) active fraction in a reference volume. The cloud centre of mass is computed as follows: in eq. 19 N p is the overall number of parcels laden in the domain in a given time-instant. In the following lines G = (x G , y G , z G ) is considered as the centre of mass components. Streamwise liquid penetration length, LPL x , is defined as the maximum distance travelled along x-axis by a parcel conserving at least 95 % of its initial mass. It is interesting to put in evidence that for this parameter, publicly available OpenFOAM functions are not used. Thus, an inline function leaning on the parcel mass stored at the domain immission is developed. Two different indexes for describing the saliva droplets' population/activation are introduced. The first index is the ratio between the number of particles present in a reference volume, Ω i , and the total number of particles in the overall domain, Ω 0 , in a given time instant: a second reference index is expressed in the following equation: Φ A,i j is the ratio of active particles in Ω j and the number of particles hosted in Ω i . The aim of Φ A,i j index is to provide a quantitative analysis of the impact of UV-C related biological inactivation. It is essential to remark that the data presented in this paper are focused on parallelpipedal reference volumes having the following features: the parameter α i , appearing in eq. 22, spans the following values: 0.5 m, 1.0 m, 1.2 m, 1.5 m which are selected in order to investigate a proper safety distance to be held in context of SARS-CoV-2 transmission containment. The transverse direction range is considered in order to completely cover the domain. Lastly, z axis interval is defined for acting on a sufficiently wide range of possible virus receivers' heights. All the computations were performed on the HPC-system CRESCO6 hosted by ENEA at Portici (Italy). CRESCO6 comprises 434 nodes with two Intel Xeon Platinum 8160 24core processors of the Skylake (SKL) generation operating at 2.1 GHz for each node. There are 192 GB of RAM available in standard nodes. The codes were built using Intel compilers and the MPI library version developed by Intel. A grid convergence study was carried out. Streamwise velocity profiles for the continuous phase were collected in order to evaluate the time evolution of the cough. In Fig. 4 and Fig. 5 the streamwise velocity, U x , behaviour in the mouthprint proximity is showed: S 2 and S 3 results are in good agreement both during the ejection phase and immediately after it has occurred. S 1 grid, instead, produces unphysical fluctuations in the entertainment zone. This is also true when the primary flux evolves into the domain (Fig. 6 -7) . For what concerns the cloud development, its centre of mass position and LPL x time evolution were monitored. Examining Fig. 8 is easy to see that S 2 and S 3 grids provide very similar behaviour. S 1, instead, underestimates G, with a major impact on x G . This is confirmed once again from the comparison in Fig. 9 . For this, S 2 was chosen as the best compromise between solution accuracy and computational load for all the following simulations. It is important to point out that, for the entire grid convergence study, Co max = 0.4 was adopted for computational efficiency reasons. In the context of the dynamic adjustable time stepping technique adopted in this work, the evaluation of the correct Co max is crucial. the cloud properties was analysed. Fig. 10 put in evidence that, for Co max 0.2, G shows the same trajectory. In fact x G as well as z G time evolution are almost indistinguishable for the first three cases. A slightly different trend was found in the streamwise liquid penetration length (Fig. 11) . In this case, LPL x , provided by assuming Co max = 0.2, does not perfectly replicates the behaviour given using lower ones. However, considering that the LPL x behaviour is slightly affected and the overall good results, Co max = 0.2 is chosen for the investigations, even for ensure acceptable computing times. In the above discussed analyses a mean number of particle per parcel N p,i ≈ 10 was considered for the sake of efficiency in the Eulerian-Lagrangian framework coupling. The intent is to complete the simulation parameters setting by means of the evaluation of N p,i effect on the droplets' cloud development. It is obvious that for N p,i → 1 each particle is independent in its interaction with the carrier fluid and, consequently, the cloud parameters are not affected by approximations due to the PSI-Cell method parcels based implementation. Moreover, as noticeable in Fig. 12 , using N p,i ≈ 1, the diameters of the particles ejected during coughing, better fit the analytic Rosin-Rammler probability density function (PDF) distribution. Finally, N p,i ≈ 1 is adopted for the purpose of achieve the cloud proper modelling in terms of its dynamical behaviour and PDF diameters size. In this subsection, all relevant features, concerning SARS-CoV-2 transmission of saliva cloud derived from coughing, are examined. A representation of the computed cloud is showed in Fig 13-14 . Note that the analyses will not be limited to a single cough ejection but also to multiple ones. Up to three cough cycles delayed by 0.38 s one over the other 9 are applied. All the pre- sented results are obtained from numerical simulations based on S 2 grid and Co max = 0.2 as showed in Secs. IV A-IV B. The simulated physical time, excluding the precursor configuration, is ∼18 s (depending on breathing) due to the fact the run is stopped when no parcels are still in the domain. The total computation time of single case is about 20 hours run in parallel using 384 CPU-cores on CRESCO6. Fig. 15 depicts fraction of particles present in the four reference volumes defined at the beginning of this section. It is really interesting to note that Φ Ω i curves are very close for 2 ≤ i ≤ 4 . So, regarding the possibility to receive infected particles when the external wind is not present, distances ranging from 1.0 m to 1.5 m are equivalent. A similar condition is highlighted in case of multiple cough ejections. Fig. 16 shows that similar droplets' contamination is produced for Ω 2 and Ω 3 for different coughing; Ω 4 results are not included in the plot to avoid the unreadability of the chart. In Fig. 17 streamwise liquid penetration length, LPL x , is depicted. In the case of a single saliva droplets' ejection O (LPL x ) 0.5 m is found; differently, when the injections' number increases O (LPL x ) rises to around 0.8 m. It is also interesting to note that, after the first cough, the LPL x curve slope grows significantly and the largest emitted particles travel not more than 1m. The centre of mass trajectory on the x-z plane is showed in Fig. 18 . The number of cough ejections does not affect largely x G , z G evolution except for its last portion. For x G 0.35m, the x G , z G curve underlines a clear trend change. Actually, in the proximity of this critical point the trajectory changes from to almost linear one up to x G 1m. This is due to the cancellation of the inertial term. In the last part of the curve, the evaporation and parcels' interaction with the bottom wall lead to a complex behaviour. The centre of mass trajectory sug- gests that several particles are located at distance over 1.5 m from the emitter. Nevertheless, a very limited number is situated within the range 1.3m ≤ z ≤ 1.8m. The biological inactivation produced by UV-C light is analysed considering all the saliva droplets introduced in the domain as fully active. A commercial cylindrical lamp (having a radius of 1.4 cm and length of 90 cm) is used a UV-C source. It is positioned at the domain top and different lamp layout were investigated. In the first case, the streamwise orientation was fixed and the closer lamp edge to the mouth print is po- sitioned in the point (0.5m, 0m, 3m). In the second configuration, the lamp is aligned to the crossflow direction and its centre is placed at (1m, 0m, 3m). Also two different power sizes were considered: 25 W and 55 W. These values were selected in order to give a limited UV-C dose to a possible cough emitter in accordance with Ultraviolet Radiation Guide published by Navy Environmental Health Center (USA) 33 . Looking at Tab. II is possible to observe the average and maximum UV-C dose (received in 10 s) related to mannequin placed at domain are deduced from a numerical integration of UV-C field irradiating the space discretisated mannequin (only in its anterior portion) represented in Fig. 19 . 19 . UV-C intensity field received by mannequin placed at domain inlet region. Crossflow oriented 55 W lamp. The effect of UV-C lamp and orientation is clearly underlined in Fig. 20 . The Φ A,00 behaviour vis-à-vis time is evident for the reported cases. Anyway, the impact of the lamp orientation is barely noticeable; the lower power level lamp produces, according to the authors' opinion, a modest biological inactivation of parcels. Thus, hereinafter the reference configuration uses a crossflow 55 W lamp. The UV-C radiation inactivation capabilities are shown in Figs. 21-23. Only Ω 2 volume is studied since it is almost equivalent to Ω 3 and Ω 4 as regards the droplets' presence. It is very important to stress that permanence time of droplets has 10 s scale for the different coughing. This condition can be also noted observing Fig. 14 . Furthermore, UV-C light has a very good impact on the reduction of active particles. Indeed, Φ A,22 index rapidly decreases in time reducing the contamination risk. In this context, it is interesting to note that after 4 s the number of parcels in Ω 2 is low and they are mainly located in its bottom side where UV-C field intensity suddenly decays, see Fig. 13 . Therefore, the overall effect of this technique can be This paper addresses the development and application of an Eulerian-Lagrangian model for saliva droplets' cloud deriving from coughing. Particular emphasis has been devoted to SARS-CoV-2 biological inactivation produced by UV-C radiation at 254 nm. Therefore, a new approach to to model the UV-C inactivation effect was introduced. A preliminary work was dedicated to the correct evaluation of grid points spacing as well as Co max and parcels' injection features. Successively, several relevant configurations have been analysed in absence of an external wind. Moreover, two indexes were introduced in order to provide quantitative informations about the contamination risk. Firstable we noted that only a few particles get to distances grater than 1.0 m, in the vertical range 1.3m ≤ z ≤ 1.8m, after different breathing conditions. Hence, it may be confirmed that social distances greater than 1.0 m do not reduce notably the possibility of receiving infected particles in not windy conditions. Furthermore, it was also showed that UV-C radiation is a promising technique to perform a real-time disinfection of a cloud resulting by coughing. Indeed, the number of active particles can be significantly reduced during the saliva droplets' cloud evolution without giving a critical UV-C dose to the emitter. Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Healthcare Settings The flow physics of COVID-19 Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review Experimental investigation of the human convective boundary layer in a quiescent indoor environment Fifty years of CFD for room air distribution Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors Numerical modeling of the distribution of virus carrying saliva droplets during sneeze and cough On coughing and airborne droplet transmission to humans On respiratory droplets and face masks Weather impact on airborne coronavirus survival Sneezing and asymptomatic virus transmission Numerical investigation of aerosol transport in a classroom with relevance to COVID-19 Dispersion of evaporating cough droplets in tropical outdoor environment A tensorial approach to computational continuum mechanics using object-oriented techniques Predicting airborne coronavirus inactivation by far-UVC in populated rooms using a high-fidelity coupled radiation-CFD model Two-Equation Eddy Viscosity Turbulence Models for Engineering Applications The Particle-Source-In Cell (PSI-CELL) Model for Gas-Droplet Flows Integratable form of droplet drag coefficient Effectiveness of Direct Lagrangian Tracking Models for Simulating Nanoparticle Deposition in the Upper Airways Comparison of indoor aerosol particle concentration and deposition in different ventilated rooms by numerical method Evaporation from drops Droplet Size Distribution in Sprays Exhaled droplets due to talking and coughing An engineering approach to the control of Mycobacterium tuberculosis and other airborne pathogens: A UK hospital based pilot study Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light 2020 COVID-19 Coronavirus ultraviolet susceptibility Radiative Heat Transfer Mathematical Modeling of Ultraviolet Germicidal Irradiation for Air Disinfection Solution of the implicitly discretised fluid flow equations by operator-splitting Visualization of sneeze ejecta: steps of fluid fragmentation leading to respiratory droplets Shear rate dependent viscoelastic behavior of human glandular salivas Assessment of Droplet Breakup Models for Spray Flow Simulations Ultraviolet Radiation Guide The authors want to acknowledge Associazione Nazionale Big Data that awarded this research work within COVID19-Fast access to HPC supercomputing facilities programme. We acknowledge ENEA for awarding us access to CRESCO6 based at Portici.