key: cord-0189734-9svp45h0 authors: Hwang, Kee Young; Jimenez, Valery Ortiz; Muchharla, Baleeswaraiah; Eggers, Tatiana; Le, Anh-Tuan; Lam, Vu Dinh; Phan, Manh-Huong title: A Novel Magnetic Respiratory Sensor for Human Healthcare date: 2021-02-02 journal: nan DOI: nan sha: 3ce1d48f979071f3e158308f3e0cd9cf45015576 doc_id: 189734 cord_uid: 9svp45h0 Breathing is vital to life. Therefore, the real-time monitoring of breathing pattern of a patient is crucial to respiratory rehabilitation therapies such as magnetic resonance exams for respiratory-triggered imaging, chronic pulmonary disease treatment, and synchronized functional electrical stimulation. While numerous respiratory devices have been developed, they are often in direct contact with a patient, which can yield inaccurate or limited data. In this study, we developed a novel, non-invasive, and contactless magnetic sensing platform that can precisely monitor breathing, movement, or sleep patterns of a patient, thus providing efficient monitoring at a clinic or home. A magneto-LC resonance (MLCR) sensor converts the magnetic oscillations generated by breathing of the patient into an impedance spectrum, which allows for a deep analysis of breath variation to identify respiratory-related diseases like COVID-19. Owing to its ultrahigh sensitivity, the MLCR sensor yields a distinct breathing pattern for each patient tested. The sensor also provides an accurate measure of the strength of breath at multiple stages as well as anomalous variations in respiratory rate and amplitude. This suggests that the MLCR sensor can detect symptoms of COVID-19 in a patient due to shortness of breath or difficulty breathing as well as track the progress of the disease in real time. Bacteria and viruses threaten our lives on a daily basis and are responsible for severe plagues. To prevent further infection, it is essential to develop high-performance healthcare monitoring devices that can detect a pathogen and provide accurate health condition data and progress [1, 2] . For instance, the development of novel respiratory devices to monitor breathing has advanced healthcare service, especially for those experiencing asthma or chronic obstructive pulmonary diseases. In December 2019, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), also known as COVID-19, began to spread across the globe and has since caused the suffering and loss of life of millions of people [3, 4] . This deadly virus has a structure similar to severe acute respiratory syndrome (SARS) and is highly contagious as it can spread from one person to another through air [5] . To represents an incredibly challenging task, recent efforts have been devoted to achieving this ultimate goal [6] [7] [8] [9] [10] [11] [12] [13] . One well-known method to detect the virus is based on the reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) [6, 7] . By collecting samples from subjects and using the reverse transcriptase enzyme, a complementary viral DNA (cDNA) is created from the RNA of the virus. Some portions of cDNA go through a polymerase chain reaction and can thus be detected after an amplification process [8] . Another method for detecting COVID-19 uses an electronic sensor. A field-effect transistor (FET), which can bind to COVID-19, has been developed and real-time changes to the electric signal have been demonstrated [9] . Optical biosensors and biochemical tests have also been employed to detect this deadly virus [10] [11] [12] . Despite the advantages they provide, these sensors are vulnerable to human contact, inaccuracy with small amounts of sample, and usually have long processing times [13] . Common symptoms of COVID-19 include: (i) shortness of breath or difficulty breathing, (ii) cough, and (iii) fever. Some patients suffer symptoms similar to lung disease such as pneumonia [5] . During the infection period, a patient likely experiences shortness of breath or difficulty breathing, which can be detected using a real-time respiratory monitoring device [14] [15] [16] . Current respiratory monitoring techniques are based on the impedance pneumography of the respiratory inductance plethysmography (RIP). By attaching electrodes to a patient's chest, the expansion and contraction of the chest causes a change in electrical impedance that can be expressed as the motion of respiration [15] . However, this contact-based method comes with limited sensitivity and reliability. It is also an inconvenient method to perform actual tests, such as children's respiratory monitoring. Therefore, there is an urgent need for the development of contactless devices that enable early and fast detection of COVID-19 or related diseases and track their growth rates in real time. In this paper, we present a novel, non-invasive, and contactless magnetic sensing platform that integrates an ultrasensitive magneto-LC resonance (MLCR) sensor with a tiny permanent magnet for applications in healthcare monitoring. We demonstrate how to use this sensing platform to monitor respiratory motion (frequency, amplitude, shortness of breath, etc.) in real time and the analysis of patients' breathing pattern at different ages, at multiple stages, after holding breath, in both wake-up and sleep modes. Based on these findings, we propose an innovative approach that integrates magnetic sensing with machine learning for the fast screening and real-time tracking of COVID-19 and related viruses. The MLCR sensor that utilizes the advantages of the giant magneto-impedance (GMI) effect of an ultrasoft magnetic Co-rich microwire [16] and an LC resonance circuit of an inductive coil made of the Co-rich microwire has recently been developed by our group for real time respiratory monitoring [17] and for spintronics applications [18] . Details of the design and fabrication of the MLCR sensor have been reported in Ref. [17] . In this study, we aimed to optimize the sensing capacity of the MLCR sensor. To do so, we performed a systematic investigation on the sensitivity of the MLCR sensor as a function of the operation frequency and the distance between the sensor and the targeted sensing object. To determine the optimized operation frequency and distance from the MMC sensor to a tiny permanent magnet, a vibrator with a non-magnetic arm was used. The waveform driving the vibrator was sinusoidal wave with 0.1 Hz frequency with 3.3 V amplitude, which was 0.5 cm from top to bottom. Changes in the external magnetic field, due to vibration of the permanent magnet, drives a change in the impedance of the MLCR sensor, corresponding to the highest and lowest peaks, which is defined as the sensitivity of the MLCR sensor (i.e. sensitivity = Zh -Zl, where Zh and Zl are the highest and lowest values of impedance). Figure 1a displays a typical vibrating (or breathing) pattern measured by the MLCR sensor as it detects the magnetic signal of a vibrating permanent magnet that was located 5 cm away from the sensor. By studying the effect of variation of operation frequency from 60 to 140 MHz on the sensor's sensitivity, we found the optimal operation frequency of 80 MHz to achieve the highest sensitivity (see Fig. 1b ). Using this optimal operation frequency, we investigated the effect of changing the distance between the sensor and the permanent magnet on the sensor sensitivity and found that the 5 cm distance is optimal for magnetic respiratory monitoring using the MLCR sensor (see Fig. 1c ). Therefore, in the thesis research, we operated the MLCR sensor at f = 80 MHz and placed it at d = 5 cm from the permanent magnet for all breathing monitoring experiments. To examine the sensing capacity and consistency of the MLCR sensor in monitoring human respiratory motion in real time, we designed experiments with the sensor held on a non-magnetic arm at a distance of 5 cm away from a tiny permanent magnet (e.g., NdFeB) mounted to the skin of a test subject. As the test subject breathes in and out, the chest will rise and fall, which generates a corresponding magnetic field change of the permanent magnet tracked by the MLCR. In other words, the motion of the permanent magnet is converted into an impedance change of the MLCR sensor. To perform human respiratory motion tests, we have designed a comfortable test configuration as illustrated in Fig. 1d . Research has shown that respiratory rate or breathing frequency decreases with age [19] [20] [21] [22] [23] [24] [25] . For instance, an infant (1 to 12 moths) breathes between 30 to 60 times per minute, toddlers The tests were repeated several times and showed reproducible and consistent results (see Fig. 2 (d-f)). These results demonstrate that each person has a characteristic breathing pattern. When one gets older, they breathe weaker and the number of breaths per minute increases. This finding is consistent with those reported in previous works [19] [20] [21] [22] [23] [24] [25] . Fig. 2(a-c) . To gain more information from these features, we analyzed the peak-to-peak time and plotted it as a function of time. As one can see in Fig. 3(a-c) , there are some abnormal changes in the breathing pattern at the previously mentioned times. Such features of abnormal breathing or shortness of breath are not detectable by an Apple Watch tracker or a commercially available respiratory monitor. This demonstrates the increased capacity of our ultrasensitive magnetic respiratory device for human healthcare monitoring. In practical applications, it is essential that a sensor is able to precisely monitor a patient's breathing in various and complex states in real time [24, 25] . Existing respiratory monitoring devices are unable to provide this information. In this study, we tested the ability of the MLCR sensor to monitor a patient's respiratory motion in simple and complex breathing states. Subject 1 was instructed to breathe in two different states, namely, the normal and deep breathing states. The MLCR sensor precisely tracked how his/her breath (breathing amplitude and rate) varied and transitioned from one state to another (Fig. 4) , which demonstrates the excellent capacity of the MLCR sensor for real-time tracking of a patient's health progress. It has been reported that breathing training can significantly enhance health and physical performance in humans [24] . A proper breath holding technique can increase the amount of carbon dioxide in our cells and help us reveal personal issues we need to confront [25, 26] . It has been shown that breath control improves lung function, which in turn preserves the health of stem cells and improves longevity, as well as promotes the regeneration of new tissues in the brain [27] . It has been reported that daily exercise of breath control can positively impact the sympathetic nervous system and the immune system by increasing the production of antiinflammatory mediators [24] [25] [26] . In this regard, we explored the ultrahigh sensitivity of the MLCR sensor for real-time tracking of a patient's breathing in multiple/complex states from holding breath (State 1) to the release of breath (State 2) and the return to normal breathing (State 3). A clear understanding of this complex breathing process provides valuable information of the patient's health and may help doctors to develop an appropriate treatment plan for the patient. In our study, subjects 2 and 3 were instructed to first hold their breath as long as they could (State 1), then release their breath (State 2), and finally come back to normal breathing (State 3). The selected test results are displayed in Fig. 5 . It is worth noticing in this figure that both the subjects underwent three distinguishable states, which were precisely tracked by the MLCR sensor. Subject 2 held the longest breath for 47 s (State 1) and, after releasing the breath, took 15 s to catch their breath (State 2) before returning to normal breathing (State 3). Meanwhile, Subject 3 held their longest breath for 30 s (State 1) and, after releasing the breath, took only 10 s to catch their breath (State 2) before returning to normal breathing (State 3). Compared to Subject 3, Subject 2 breathed more regularly after releasing their breath toward the normal breathing state. These findings seem to suggest that when getting older, one's ability to hold his/her breath decreases to a shorter period of time and they may experience more respiratory issues. Using this testing method, one can be aware of their current health status and be encouraged to follow an appropriate breathing control method to improve health and physical performance. Nowadays, many people experience insomnia, sleep difficulties, dream sleep, or chronic trouble falling asleep. According to the American Sleep Association (ASA), insomnia is the most common sleep disorder [28] . Currently, about 30 percent of American adults are facing with insomnia. Insomnia can arise for various reasons such as irritability, depression or anxiety, stress from multiple work tasks, medical conditions, or mental health disorders and it can reduce our health, work performance, and quality of life. Research has shown that breathing training techniques can help us relax, sleep, and breathe more naturally and effectively [24, 29] . Before using such techniques, it is essential to understand what affects our breathing before, during, and after our sleep [29] . In this context, there is an urgent need for the development of a highly sensitive, contactless respiratory monitoring device that can precisely monitor human respiratory motion in real time in these states. Owing to its ultrahigh sensitivity, the MLCR sensor is expected to fulfil this requirement. In this study, we examined the capacity of the MLCR sensor in monitoring a patient's respiratory motion during sleep, as well as tracking a transition of his/her respiratory motion from wake-up mode to sleep mode. First, we show how respiratory motion of a patient can be tracked in real time during sleep by the MLCR sensor. In this case, the breathing pattern of Subject 2 (36 YO) was tracked while the subject was sleeping. As one can see clearly in Fig. 6 , the sleeping patterns were clearly recorded. It is worth noticing that an abnormal breathing or a shortness of breath occurred around t = 80 s. This may suggest that this subject experiences some respiratory problems or associated diseases. Next, we tracked how the respiratory motion of a patient (Subject 1 and Subject 3) changed during their wake-up or sleep period, as well as from the transition from wake to sleep mode. The breathing patterns of Subject 1 (30 YO) were continuously tracked from wake to sleep mode, the result of which is shown in Fig. 7 . This figure clearly shows a clear breathing transition of the subject from the wake-up to the sleep mode. It is also worth noting that in sleep mode, the subject breathed more deeply (higher amplitude) and slowly (11 times per minute) as compared to the wake mode (12 times per minute). In a similar fashion, the breathing patterns of Subject 3 (42 YO) were continuously tracked from wake to sleep mode (see Fig. 8 ). The sensor precisely tracked how his breath transitioned from wake to sleep mode. In sleep mode, the subject breathed more deeply (higher amplitude) and slowly (14 times per minute) as compared to the wake mode (20 times per minute). The results obtained from both Subject 1 and Subject 2 consistently pinpoint the fact that, in a normal sleep mode, one tends to relax and sleep better than during the wake mode. Relative to Subject 1, there is more of a difference in the respiratory rate between the wake and sleep mode found for Subject 3. This suggests that older people tend to relax more during sleep [29] . In addition, the ultrahigh sensitivity of the MLCR sensor enables the detection of abnormal breathing around t = 40 s in both the wake-up and sleep breathing patterns for Subject 3. This indicates that the noticed abnormal breathing is intrinsic to Subject 2 and that this subject should be aware of this potential respiratory issue or related disease (e.g., chronic pulmonary disease) and should thus perform daily breathing training/exercises to resolve it [24, 29] . We have developed an innovative, contactless magnetic respiratory monitoring platform based on ultrasensitive magneto-LC resonance (MLCR) technology and a permanent magnet. This technology has been successfully applied to test human respiratory motion in real time and in different states. We demonstrated that the MLCR sensor can track a person's breathing pattern very precisely in real time over the course of multiple states (normal breathing, holding breath, and sleeping). Owing to its ultrahigh sensitivity, the sensor yielded a distinct breathing pattern for each person tested and revealed abnormal breathing, which is superior to existing respiratory monitoring devices. We have shown that when getting older, one usually manifests weaker breathing marked by an increasing breathing rate. He/she tends to hold his/her breath for a shorter period of time and often experiences more with respiratory issues than younger people. People become more relaxed, thus breath more regularly and slowly while sleeping as compared to the wake-up mode. Our highly sensitive magnetic respiratory monitor provides not only valuable information on a patient's current health status, but also a novel breathing control tool for improving our health and physical performance. Through these studies, we also identify several exciting and important applications of our novel magnetic respiratory monitoring technology for advanced human healthcare systems. In particular, research on the practical implementation of this technique for the fast screening and real-time tracking of COVID-19 or associated viruses is very exciting and worth pursuing. Monitoring COVID-19 patients remotely with the MLCR detector and collecting data from numerous physiological signals, with the help of machine learning, would improve clinical decision making for providers [29] [30] [31] [32] . The Fast Fourier Transform (FFT) algorithm, which converts a signal from the time domain to the frequency domain and vice versa, can be used to extract spectral features from breathing patterns. This can also be used by machine learning and other algorithms for signal processing and to provide comprehensive information on a patient's health status and physical performance. Temperature correction of blood gas and pH measurement -an unresolved controversy An introduction to the history of infectious diseases, epidemics and the early phases of the long-run decline in mortality, The Economic History Review Structure, Function, and Antigenicity of the SARSCoV-2 Spike Glycoprotein A Pneumonia Outbreak Associated with a New coronavirus of probable bat origin COVID-19: A Global Transplant Perspective on Successfully Navigating a Pandemic Development of a Real-Time Reverse Transcriptase PCR Assay for Type A Influenza Virus and the Avian H5 and H7 Hemagglutinin Subtypes Detection and Analysis of Nucleic Acid in Various Biological Samples of COVID-19 Patients Selection of Fluorophore and Quencher Pairs for Fluorescent Nucleic Acid Hybridization Probes Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor Integrating Waveguide Biosensor Temporal Profiles of Viral Load in Posterior Oropharyngeal Saliva Samples and Serum Antibody Responses During Infection by SARS-CoV-2: An Observational Cohort Study Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19 Clinical Method: The History, Physical, and Laboratory Examinations Respiratory Care: Principles and Practice Giant magnetoimpedance materials: Fundamentals and applications A new contactless magneto-LC resonance technology for real-time respiratory motion monitoring A magnetic sensor using a 2D van der Waals ferromagnetic material A medical cloud-based platform for respiration rate measurement and hierarchical classification of breath disorders Respiration rate monitoring methods: a review Electromagnetic biosensing of respiratory rate A new system for continuous and remote monitoring of patients receiving home mechanical ventilation Noncontact respiration rate measurement system using an ultrasonic proximity sensor Breathing Monitoring and Pattern Recognition with Wearable Sensors Respiratory rate monitoring: characterizing performance for emerging technologies The ins and outs of breath holding: simple demonstrations of complex respiratory physiology SIRT7 and Stem Cell Aging: Holding Your Breath for Longevity Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath Detection of antibodies against SARS-CoV-2 spike protein by gold nanospikes in an opto-microfluidic chip The potential of electrochemistry for the detection of coronavirus-induced infections Future developments in biosensors for fieldready SARS-CoV-2 virus diagnostics Research at USF was supported by the USF Covid19 Research Foundation under Grant number 125300. The work was also supported by Vietnam Ministry of Science and Technology through the national-level project ĐTĐLCN.17/19.