key: cord-0114737-n8qschmr authors: Sharma, Shubham; Pinto, Roven; Saha, Abhishek; Chaudhuri, Swetaprovo; Basu, Saptarshi title: Secondary Atomization and Possible Aerosolization of Cough Droplets through Single and Multi-layer Face Masks date: 2020-09-04 journal: nan DOI: nan sha: 1bb962ef5c0a845c1f2cf239c485886406fa85c3 doc_id: 114737 cord_uid: n8qschmr Usage of face masks are strongly encouraged by health officials, to prevent the spread and transport of respiratory droplets. In this study, however, we show that a single layer of a surgical mask can atomize a cough droplet into numerous tiny droplets, thereby significantly increasing the total population of aerosols ejected during a single human cough. Although droplets of a broader size distribution are ejected during coughs, we focused our attention towards a relatively large droplet size (~ 620 {mu}m), which shows great affinity to undergo atomization during its penetration through the mask layers. The entire phenomenon was captured using a high-speed shadowgraphy imaging technique at a recording rate of 6500 fps. The single-layer masks were found to be ineffective in restraining cough droplets while no penetration could be noticed for a triple-layer mask. This is because a single-layer or double-layer face mask causes atomization of the droplets resulting in the formation of larger number of droplets with smaller sizes (<100 {mu}m). These tiny droplets can aerosolize in the immediate environment and can remain suspended for a longer time. Thus, it is recommended to avoid the use of a single-layer or double-layer surgical face mask as a physical obstruction to the ejected cough droplets for controlling the spread of the COVID-19 virus. mask substitutes have identical safety as surgical face masks. At the same time, few alternatives like neck fleece or bandanas offer very limited protections. Dabouk and Drikakis 18 have numerically shown that a few droplets are transmitted to longer distances even after being obstructed by the face mask, and the efficiency of a face mask keeps on diminishing with increasing cough cycles. Sahu et al. 19 found that for any fiber-liquid combination there exists a threshold impact velocity above which liquid can penetrate the porous network of fibers irrespective of its hydrophobicity. Verma et al. 20 compared the different commercially available face masks in terms of their efficiency in obstructing respiratory jets. They used a laser sheet illuminating the aerosols jets and calculated the distance traveled by the jets for the case of the unmasked and masked subjects. The use of face-covering significantly reduced the distance traversed by the jets; however, a significant amount of aerosol leakage was found from the sides of the face mask. A similar study was conducted by Kahler and Hain 21 for a much smaller size of suspended droplets (0.1 − 2 ) and suggested the use of particle filtering unit in mask for increasing their effectiveness. The available literature indicates that N95 masks are effective in limiting the spread of dispersions during human coughs, but their shortage and high costs in the ongoing pandemic has forced policy makers to shift to other alternatives like single or multi-layer surgical masks or other homemade substitutes. The earlier works on the surgical face mask were mainly concentrated on determining the spreading distance of cough puffs and their leakages from the sidewalls of the mask 14, 16, 18, [20] [21] [22] [23] [24] . The above works address smaller sized droplets (~ 0.1 to 100 ) which can easily transmit through the porous network of the mask without undergoing any further atomization. These studies lack in presenting the fluid dynamics aspects of cough droplets impinging on the mask including the droplet penetration criteria, atomization mechanism of the impacting droplets and the final size distribution of the atomized secondary droplets that are expelled. In the present investigation, we have focused on these aspects and studied the breakup mechanism of larger cough droplets (~ 600 ) having an initial velocity of ~10 / and impacting on a single or multi-layer surgical mask. As will be shown later, the droplet impact leads to the fragmentation of larger cough droplets into numerous tiny droplets (~ 10 − 200 ) with significant translational velocity (~ 4 / ). These tiny droplets can move to greater distances and can remain aerosolized in the medium for longer durations and hence increases the risk of infections. Figure 1 (a) shows the schematic diagram of droplets ejected during human coughs. A zoomed-in view shows the droplet impacting on the inner layer of the mask and disintegrating into finer daughter droplets on the other side of the mask. Human coughs contain respiratory droplets with a wide range of size distribution (0. 5 -2000 ) 4 and with an ejection velocity of ~ 10 m/sec. For generating droplets at such high speeds, a piezo-actuated droplet dispenser (Nordson picopulse) is used, which ejects DI water droplets of ~ 620 size with an impact velocity of ~10 m/sec. A high-speed shadowgraphy setup is made for visualizing the droplet impingement on the masked surface, as shown in Fig. 1 (b) . The light from an LED source (Moritex Schott LLS 3) is collimated into a parallel beam using a beam collimator (Thorlabs -BE20M-A). The shadow image of the droplet is captured by a high-speed camera (Phantom Miro Lab 110) coupled with a zoom lens assembly (NAVITAR 6.5x lens and 1x adapter tube) at a recording rate of 6500 fps and exposure time of 5 . A pixel resolution of 15.3 / is used during the experiments, which covers a field of view of 6.8 mm x 8.4 mm. Surgical masks with different numbers of protection layers are used during the experiments. A zoomed-in image of mask porosity is shown in Fig. 1 (c-e). The microscopic images show the porous network formed by the threads of the mask layer. The mask layer has a range of pore diameters, and the average effective pore diameter was found to be ~ 35 . Thus, overlapping layers of these masks reduces the effective porosity depending on the relative arrangement of pores in the multiple mask layers, as shown in Fig. 1 (d-e) . The mask material used for a single-layer is hydrophobic ( Fig. 1 (f) ) and the contact angle is measured to be 115 ± 8 . Figure 2 (a) shows the case of a single-layer mask, in which the impacting droplet is fragmented into multiple liquid ligaments (see = 304 − 456 ), and these ligaments subsequently undergo secondary atomization into multiple daughter droplets (see = 608 − 912 ). Figure 2 (b) shows the case of a double-layer mask. Here, the number of droplets penetrating through the mask is significantly less in comparison with a single-layer mask (see = 304 − 1368 ) due to a reduction in the effective porosity of the mask. The cylindrical ligaments are not observed in this case due to the presence of the second mask layer. Figure 2 (c) shows the droplet impacting on the three layers of the surgical mask. No penetration of impacting droplet is noticed on the other side of the mask due to the much smaller effective porosity of triple-layer masks. Similar results were also observed for N95 face masks. Thus, triple-layer masks and N95 masks are not only useful in restricting larger respiratory droplets, but they also inhibit the further atomization of droplets that are ejected during the cough of an infected person. The scaling analysis adapted from Sahu et al. [19] for determining the criteria for droplet penetration is obtained as follows. The impacting droplet has initial kinetic energy ( ≈ ( ) 2 3 ) which is lost into dissipation energy ( ≈ ( ) ( ) 3 ) when the liquid ligaments pass through the porous network of the mask. Here, and are the pore size and thickness of the mask layer, and are the density and dynamics viscosity of the droplet, respectively. If the kinetic energy overcomes the dissipation energy, the impacting droplet penetrates through to the other side of the mask layer. The scaling argument for this criterion is given by Sahu et al. [19] by the ratios of two energies: Here = ( ) is Reynolds number based on the pore size. Therefore, for the droplet to penetrate through the mask layer, the above ratio should be much greater than one and the droplet penetration criteria is obtained as [19] : The droplet penetration depends on its impact velocity and the thickness and pore size of the mask and it is independent of the diameter of impacting droplet 19 . In case of single layer mask ( ~ 398 and / ~ 10.6) ≫ / therefore the impacting droplet is able to penetrate through the mask layer. Similar quantification could not be done for multi-layer masks as their pore size depends on the relative arrangement of mask layers and cannot be measured through the microscopic images (see Fig. 1 (d-e) ). A qualitative look at equation 3 shows that due to smaller pore size the Reynolds number decreases and the thickness to pore ratio increases for a multi-layer mask. Thus, droplet penetration criteria (Eqn. 3) is no longer valid for these masks and we observed a minimal or no droplet penetration for double and triple-layer face masks, respectively. The detailed mechanism of droplet breakup and size distribution is discussed in the following section. The zoomed-in images of droplet atomization are shown in Fig. 3 . For impacting droplets, Weber number ( = = 2 ) governs the relative importance of inertia and surface tension forces acting on the droplet, where is the surface tension of water (droplet substance) in the air (surrounding gas medium). For a higher as in the present case ( = 875.9) the inertial forces dominate over the surface tension forces and hence results in the deformation of the droplet as it impacts the mask surface. Based on the penetration criteria discussed in the previous section, the impacting droplet extrudes through a single-layer mask in the form of cylindrical ligaments (see Fig. 3 at = 304 ) . The length of these ligaments increases over time ( = 304 − 456 ) due to which instabilities in the form of capillary waves are formed on its surface. Among all the instabilities, few dominant unstable wavelength amplitudes grow over time and result in the formation of thinner and thicker diameter regions along the length of the ligament (see Fig. 3 (a) at = 608 ). Hence, different surface curvatures are formed on the ligament, which results in a Laplace pressure gradient along its length and the formation of high-pressure regions at smaller diameters and low-pressure regions at larger diameters. This pressure difference results in liquid flow inside the ligament, hence further reducing the thickness at smaller diameters and increasing it at larger diameters. At later time instances, the smaller diameter regions of the ligament get pinched off, and droplets of larger ligament diameter are formed. This manner of the breakup of droplet ligament is triggered through a Rayleigh-Plateau mode of instabilities 25, 26 . Figure 3 (b) shows a zoomed-in image for a double-layer mask. As discussed earlier, a minimal amount of initial droplet volume penetrates through the mask, and no ligament formation is observed in this case due to the presence of the second mask layer. The probability distribution function for the diameter of atomized droplets for single-layer and double-layer masks is shown in Fig. 4 . The droplets with diameters smaller than 100 have higher aerosolization tendency, and these droplets are mentioned as critical droplets in the text hereafter 27 . The atomized droplets are distributed over a size range of 17-288 among which 73.49 % and 85.82 % of the droplets are of critical size for single-layer and double-layer masks, respectively. The initial volume ( ) injected on the mask surface is 123.40 ± 14 , out of which 64.3 % and 3.7 % penetrated ( ) the mask, 13.07 % and 1.87 % fell in the critical range ( ) for single-layer and double-layer masks, respectively. The above discussion indicates that the singlelayer mask performs poorly not only in restricting the transmission of cough droplets but also atomizes a higher percentage of the initial volume. The double-layer masks perform better in restricting the droplet penetration, but among the droplets which penetrate the mask, they are more likely to exist in the critical regime. The average velocity of all the atomized droplets is ~ 1.5 m/s, while the minimum and maximum velocities are ~ 0.12 m/s and ~ 4.2 m/s for both single-layer and double-layer masks. Thus, these droplets have sufficient momentum to travel longer distances, hence infecting larger regions. In summary, the atomization mechanism of larger cough droplets impinging on different layered surgical masks is studied in this work. The results of droplet atomization were compared in terms of droplet penetration, size distribution, and volume transmission. Table 1 shows the effectiveness of different surgical masks investigated in this study. For a droplet of initial diameter of 620 micron, a single-layer mask restricts only 35.7 % of the initial droplet volume and is found to be the least effective among all the tested masks. The double-layer mask performs better comparatively and restricts 96.3 % of the initial droplet volume, but 85.82 % of transmitted droplets fall in the critical droplet diameter regime. No droplet ejection was observed for the triplelayer mask. Thus, in the current pandemic situation in which the N95 mask is not easily accessible Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals World Health Organization. Transmission of SARS-CoV-2: implications for infection prevention precautions. Scientific brief Influenza A viruses are transmitted via the air from the nasal respiratory epithelium of ferrets The size and the duration of air-carriage of respiratory droplets and dropletnuclei Modeling the role of respiratory droplets in Covid-19 type pandemics Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community Analyzing the dominant SARS-CoV-2 transmission routes towards an ab initio SEIR model Characterization of expiration air jets and droplet size distributions immediately at the mouth opening Concentration, size distribution, and infectivity of airborne particles carrying swine viruses Viability and infectivity of microorganisms in experimental airborne infection Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents Effects of air temperature and relative humidity on coronavirus survival on surfaces Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Respiratory virus shedding in exhaled breath and efficacy of face masks Universal use of face masks for success against COVID-19: evidence and implications for prevention policies Exhaled Air Dispersion during Coughing with and without Wearing a Surgical or N95 Mask Low-cost measurement of facemask efficacy for filtering expelled droplets during speech On respiratory droplets and face masks Drop impacts on electrospun nanofiber membranes Visualizing the effectiveness of face masks in obstructing respiratory jets Fundamental protective mechanisms of face masks against droplet infections Face mask use and control of respiratory virus transmission in households Textile Masks and Surface Covers-A Spray Simulation Method and a "Universal Droplet Reduction Model A schlieren optical study of the human cough with and without wearing masks for aerosol infection control Breakup of a fluid thread in a confined geometry: Droplet-plug transition, perturbation sensitivity, and kinetic stabilization with confinement Drop and spray formation from a liquid jet Droplet fate in indoor environments , or can we prevent the spread of infection ? Indoor Air Table 1 : Effectiveness of different surgical masks for the general populace, the use of at least a triple-layer face mask is recommended. This not only restricts the droplet transmission but also prevents the formation of atomized secondary smaller droplets.