key: cord-0078987-3gbrmm9b authors: Dargent, Auguste; Hombreux, Alexandra; Roccia, Hugo; Argaud, Laurent; Cour, Martin; Guérin, Claude title: Authors response: Feasibility of non- invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients date: 2022-05-25 journal: J Crit Care DOI: 10.1016/j.jcrc.2022.154073 sha: eb73a4ed83339c13f64ea672ea50fd140a4b42b6 doc_id: 78987 cord_uid: 3gbrmm9b nan Authors response: Feasibility of non-invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients We thank Antonio Esquinas and co-authors for critically discussing the results of our study "Feasibility of non-invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients", recently published in the Journal of Critical Care [1] . We would like to take the opportunity to respond to the authors' concerns and to clarify some methodological points of our study. First, regarding the amount of positive end-expiratory pressure (PEEP) applied with high-flow nasal cannula (HFNC) and its equivalence with continuous positive airway pressure (CPAP). Although HFNC demonstrated a true PEEP-like effect with an increase in endexpiratory lung volume (EELV) [2] , it is true that this effect is very limited and is not equivalent to conventional CPAP. Furthermore, a direct comparison of CPAP and HFNC is difficult because the airway pressure level during HFNC is highly variable between patients and during the respiratory cycle [3] . In the most optimal conditions, HFNC can provide up to 3 cmH 2 O of end-expiratory tracheal pressure (5 cmH2O with closed mouth) [3, 4] . PEEP level is much higher, around 10-11 cmH 2 O, when CPAP is used during acute hypoxemic respiratory failure (AHRF), especially during the COVID-19 pandemic [5] . In our study, we deliberately chose a lower CPAP pressure level. Indeed, our objective was not to assess the effect of PEEP on the respiratory drive. CPAP was rather an instrument in determining physiologic parameters, in conditions as close as possible to HFNC's. The effect of PEEP on respiratory drive was explored in the experimental work of Morais et al., cited by the authors [6] . This study showed that PEEP-induced lung recruitment in spontaneously breathing animals decreased the intensity of inspiratory effort, and decreased both localized pulmonary stretch and subsequent self-induced lung injury. In some of our patients, CPAP may indeed have induced a lung recruitment (despite low pressure levels and a short application), which could have lowered respiratory drive and effort. Some evaluation of EELV, as it can be done with electrical impedance tomography, might have address this potential bias. Second, the authors noted the hypocapnia observed in our patients and questioned its interaction with respiratory drive. During AHRF, the relation between PaCO 2 and minute ventilation (Ve) changes, with an uncoupling of the so-called "ventilation curve" (Ve change induced by a PaCO 2 change) and the "brain curve" (i.e. the neural respiratory drive for a given PaCO 2 ) [7] . This results in a higher sensitivity to CO 2 and explains why patients with AHRF are generally hypocapnic. Thus, decreased PaCO 2 and increased P0.1 are both related to increased respiratory drive. Finally, the reliability of respiratory drive parameters is questionable with a non-invasive interface such as a face mask, and the air leaks it generates. These leaks are likely to underestimate the true P0.1 value. In spite of this limitation, in all of our patients P0.1 was much higher than the normal values, indicating a high respiratory drive, which was expected in them. However, CPAP-assisted measurement of P0.1 is probably decreasing the signal-to-noise ratio of this parameter (validated in invasive mechanical ventilation), and we agree with the authors' final comment that further clinical trials are warranted to validate the accuracy of P0.1 in this setting. The authors declare that they have no competing interest. Feasibility of noninvasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients Nasal high-flow therapy delivers low level positive airway pressure High flow nasal oxygen generates positive airway pressure in adult volunteers Helmet CPAP treatment in patients with COVID-19 pneumonia: a multicenter, cohort study High positive end-expiratory pressure renders spontaneous effort noninjurious Respiratory drive in the acute respiratory distress syndrome: pathophysiology, monitoring, and therapeutic interventions Service de Médecine Intensive-Réanimation, F-69437 Lyon, France APCSe VetAgro Sup UPSP 2016.A101, Marcy l'Etoile, France ⁎Corresponding author at: Hospices Civils de Lyon E-mail address: auguste.dargent@chu-lyon.fr