key: cord-0077000-wsh17yp7 authors: Kumar, Saurabh; Chauhan, R.K.; Kumar, Manish title: Sensitivity Enhancement of Dual Gate FET Based Biosensor Using Modulated Dielectric for Covid Detection date: 2022-04-12 journal: Silicon DOI: 10.1007/s12633-022-01865-7 sha: 5f220c9d1405e2798c4d1f83284734c613a7db71 doc_id: 77000 cord_uid: wsh17yp7 This paper presents a dual gate dielectric modulated FET (DGDMFET) biosensor with enhanced sensitivity for covid detection. In earlier literature, the biosensors are operated using the surface interaction with the virus biomolecules that are reflected through a channel or gate. The downside of these types of sensors has limited sensitivity. In this paper, we have considered that the change in the dielectric constant due to virus proteins results in a significant shift in the threshold voltage of FET. Enhancement of sensitivity is done by using the novel dual metal gate arrangement with different work functions (higher at the source end and lower at the drain end) and the chromic oxide (Cr(2)O(3)) layer, which is carved out vertically to form nanogap. At the same time, interface charge density is maintained nearly equal to 1.0 × 10(11) cm(−2) at the Si-SiO(2) layer. To demonstrate the proposed biosensor, electrical parameters (electron concentration, surface potential, energy band distribution, and electric field) and the absolute percentage sensitivity of threshold voltage, subthreshold slope, ON current, and transconductance are evaluated and compared with related literature. The ATLAS device simulator is used for the simulation of the proposed device. Coronavirus disease 2019 (COVID- 19) was declared a pandemic on March 13, 2020. In December 2019, a COVID-19 outbreak was reported; it caused the world's economic recession and millions of deaths [1, 2] . In the year 2002-2003, severe acute respiratory syndrome coronavirus (SARS-CoV) [3] . In 2012 the Middle East Respiratory Syndrome coronavirus (MERS-CoV) [4] . The recent one is the new type of SARS, namely SARS-COV-2 is also caused by coronavirus only [5] . This virus is transmitted through touching a contaminated surface that contains a virus, coming in direct contact with the infected person's respiratory droplet (generated at the time of coughing and sneezing) [6] . The SARS-CoV-2 has been found in feces samples, so virus transmission can occur through an unhygienic and unhealthy lifestyle. It has been observed that in many cases, the virus is transferred through asymptomatic patients [7, 8] . The complication due to COVID-19 is coagulopathy, neurologic complications, postacute COVID-19 syndrome (PACS). Increased fibrinogen levels and D-dimer characterize coagulopathy, which causes venous thromboembolism (VTE), thromboprophylaxis. In neurologic complications, reported complications include stroke, encephalitis, meningitis, myalgia/myositis, Guillainbarre syndrome, acute disseminated encephalomyelitis (ADEM), acute hemorrhagic necrotizing encephalopathy, and ataxias [9] . According to WHO, on august 6, 2021the reported death due to COVID-19 was 4,265,903, which is enough to horrify the world. No specific drugs or vaccines against COVID-19 have been available till now. Therefore, social distancing, personal hygiene, isolation of infected people, mass screening of infected ones (with or without symptoms), and timely treatment have shown positive responses to break the chain of community transmission [10] . Along with the pathological information, the structure of SARS-CoV-2 is also needed to design the biosensors to detect COVID- 19 . The structure of the SARS-CoV-2 virus contains a circular shape of a thin membrane, spike proteins, and envelope; this image is issued by the center for disease control and prevention (CDC), USA [11] , as shown in Fig. 1 . There are three different diagnosis processes involved in the detection of SARS-CoV-2, including (1) RNA detection using real-time reverse transcription-polymerase chain reaction (RT-PCR) assay [12] , (2) fully automatic chemiluminescence method, lateral flow assays, enzyme-linked immunosorbent assay (ELISA) for the determination of antibodies [13] , (3) CT scan of the chest along with clinical indications [14] . Nevertheless, a chest CT scan has many drawbacks, like it does not differentiate whether the infection is caused by SARS CoV-2 or by any other virus. It requires a welltrained radiologist to analyze the CT scan images, it is costly enough for poor people, and also it is only limited to big hospitals. ELISA is the conventional method to detect the virus. The associated antibodies in the blood serum of the patients are observed to detect the virus, not the virus directly is detected. In the ELISA test, the presence of IgG (immunoglobulin G) antibodies in human serum indicates that the person was infected with the SARS CoV-2 virus in the past and has now developed an appropriate immune response to combat the virus in their system. The detection of immunoglobulin M (IgM) antibodies in human blood serum indicate that the person is recently infected with the virus. ELISA test for SARS CoV-2 is performed by fixing the S-protein of the virus on the testing plate, and the patient's blood sample (mainly the serum) is occupied over it. Suppose the antibodies are present in the patient's blood sample-like IgG or IgM. In that case, it attaches with the spike protein of the virus immobile on the plate of the testing kit, the linkage of the patient's antibody and HRB (which is lab manufactured having red color antibodies) make substrate colorless. It indicates that the patients have been infected with the SARS CoV-2 virus [15, 16] . Advanced and rapid testing kits follow the RT-PCR testing method; RNA is converted into complementary DNA first. Then, the DNA signal is amplified by using a real-time polymerase chain reaction. In RT-PCR, the probe strand, which contains two dyes: a quencher and a reporter, binds to a specific target sequence to virus SARS-CoV-2, placed between the forward and reverse primer. During the PCR cycle extension phase, the bound probe is degraded by the polymerase, which causes the separation of reporter dye from the quencher dye, due to which the fluorescent signal is increased. At each amplification cycle, the fluorescent intensity is monitored; as more copies of DNA are produced, the fluorescence signal increases, and when it crosses a certain threshold set above an expected background level. The result is positive, and if the fluorescence threshold is not reached, the result is then negative. The RT-PCR test is time-consuming and requires a trained technician [17] . So, to overcome these disadvantages, new devices and diagnostic tests for virus detection in clinical samples that are faster, more precise and reliable, more accessible, and cost-efficient than existing ones are needed. Ion sensitive field-effect transistors (ISFET) and microelectronic device sensors based on thin-film transistors have been a low-cost alternative to traditional chemical sensors since the early 1970s. However, lack of parasitic sensitivity to light and temperature, instability of sensor parameters and prominent space on-chip, etc. Make the researchers invent new nanodevices for sensing applications [18] . FET-based biosensors known for their widespread sensing capability revolutionize the health industry and can also be used to maintain our ecosystem. Much research has been made to increase the Silicon sensitivity and decrease the power required to operate such devices [19] [20] [21] [22] . Tunnel field-effect transistor (TFET) based biosensor achieves superior sensitivity and response time than conventional FET-based biosensor, but TFET suffers from fabrication complexity [23] [24] [25] . Silicon on Insulator (SOI) has the advantage of better gate control over the channel, low area of the source, and drain junction. The substrate's electrical insulation reduces its static and dynamic power dissipation due to lower leakage current; SOI MOSFET is the first choice for typical power applications. It can be used to operate at higher temperatures. The direct adaptation of the bulk IC design method is allowed for SOI; it requires fewer photolithography steps [26] [27] [28] . The use of chromic oxide as a gate dielectric material in field-effect transistors provides a better result as compared to other high K materials because it shows high oxidation resistance, high melting temperature, wide bandgap, and low dielectric loss. Due to its properties, it can also help to increase the sensitivity of FET-based biosensors [29] . In this manuscript, a dual gate FET-based biosensor has been proposed, which can be used to detect the virus through the dielectric constant of the Converted-DNA and Spikeprotein of SARS CoV-2. We can sense the virus in two ways, the first one is S -protein recognition, and the second one is DNA protein recognition. The DNA dielectric constant ranges from 1 to 64 [30] . Spike-protein of the SARS Cov-2 virus consists of glycoprotein; in general, the spike protein of the virus is similar to proteins like 3-aminopropyltriethoxysilane (APTEs), biotin, and streptavidin, so its dielectric constant may lie somewhere between 1 to 4 [31] [32] [33] [34] . In this paper, we have checked the sensitivity in both ways of the proposed DGDMFET. The proposed device is a dual gate dielectric modulated fieldeffect transistor designed to detect SARS-CoV-2 and other viruses. It is different than conventional MOSFET because it consists of nanogap at the edge of the gate dielectric where the biomolecules are attached for detection purposes. In the traditional MOSFET, when the gate voltage is applied, it creates an electric field that affects channel potential through the gate dielectric in a silicon substrate. In the conventional MOSFET, when the channel is formed on the silicon substrate, it will start conducting, and it is known to be in an ON state. The gate voltage at which the channel is formed is known to be threshold voltage (V th ). In the proposed sensor device, the amount of gate voltage is insufficient to turn on the silicon channel because the electric field is not enough due to the nanogap formed, which is filled with air (dielectric constant = 1). The threshold voltage (V th ) value for the proposed sensor device is large as compared to conventional MOSFET because the dielectric constant of air is 1, while that of SiO2 is 3.9, so when the nanogap is formed, which is filled with air increases the V th value. When the nanogap is filled with a biomolecule whose dielectric constant is more than air, the electric field is strengthened, decreasing the V th value. By monitoring this change in V th . The biomolecule-specific binding is electrically detected without labeling. Figure 2 shows the proposed sensor structure and its relevant dimension. The gate length of the proposed sensor is 1um, in which the gate one and gate two lengths are 500 nm and 500 nm, respectively. Gate one is made up of gold (Au), and gate two consists of tungsten (W). The source or drain length is 250 nm, the SiO2 (oxide) thickness is 5 nm, and the Cr 2 O 3 thickness is 15 nm. Both the nanogaps are of length 350 nm and thickness is 15 nm which is large enough for immobilization of biomolecules and their detection. The thickness of buried oxide is 130 nm, and its length is nearly equal to the lateral length of the device, which is 1500 nm; the width of the whole device is 1um. Figure 3 shows the fabrication process of the proposed sensor device; for fabricating the proposed sensor device conventional complementary metal-oxide-semiconductor (CMOS) process is used. Photolithography and ion implantation after the device isolation step is used for defining the source and drain region. SiO 2 , Cr 2 O 3, and dual gates (Au and W) are sequentially grown and deposited using thin film. Fabrication of dual metal gates is done using the interdiffusion process of one metal on to other [35] . Silicon oxide and Cr 2 O 3 form the gate dielectric of the proposed sensor device. These three layers, after deposition patterned by a photolithography process and the subsequent process of etching, lateral wet etching of Cr 2 O 3 is done to form the nanogap. According to Kim, the threshold voltage of a conventional nchannel MOSFET is defined by Eq. (1) [30] . V FB represents flat band voltage, V th is the threshold voltage, φ B is the surface-band banding, Q fCD is the fixed charge density in the SiO 2 layer and Q dCD is the depletion charge density. C OX is the oxide capacitance of gate dielectric material which is SiO 2, in the case of conventional n-channel MOSFET? Applying the above equation to the proposed sensor structure, we can get Silicon where, The total capacitance of the gate dielectric material is given by C DGDMFET . Parameters mentioned in eq. (3) are C biomole , T biomole , K biomole they represent the capacitance, thickness, and dielectric constant of the biomolecule. C air , T air represent the capacitance and thickness of air. T Sio 2 , C Sio 2 , K Sio 2 represent the capacitance, thickness, and dielectric constant of silicon dioxide, i.e., SiO 2 . T Cr 2 O 3 , C Cr 2 O 3 , K Cr 2 O 3 represent the thickness, capacitance, and dielectric constant of Cr 2 O 3 . From the Eqs. (2) and (3), it can be clearly analyzed that C PDOX can be altered only by the dielectric constant and charge of biomolecules. Cr 2 O 3 and SiO 2 are the dielectric material apart from the nanogap region, and it can indicate that V th is always lowered in Cr 2 O 3 and SiO 2 region as compared to air (nanogap region). Therefore, V th will respond more sensitively to the change in the nanogap region dielectric constant. According to Eqs. (2) and (3), V th can be estimated when neutralized DNA is introduced in the nanogap region. V th can be altered when the previously immobilized DNA in the nanogap region acts as a probe DNA and is hybridized with the target DNA. The dielectric constant of the biomolecule layer increases with the increment of the density of the biomolecule layer. The proposed sensor device is the extended form of the actual device [36] with the dual gate and Cr 2 O 3 oxide layer modification. The simulation of the proposed sensor device is done using a single gate and dual-gate. In the dual-gate structure, gate one that is nothing but gold (Au) is attached to the source side, and gate two wolfram (W) is attached to the drain side. Figure 4 shows a variation of charge density at the Si-SiO 2 interface on a single gate proposed device structure. For dielectric constant (K = 2.1), the percentage V th sensitivity decreases as interface charge density increase beyond 1.0 × 10 11 cm −2 and percentage V th sensitivity increases for dielectric constant (K = 4.1) with an increase in interface charge density. Therefore, the optimal value of interface charge density is chosen as 1.0 × 10 11 cm −2 for simulation and further explanation. The percentage sensitivity is calculated using Eq. (4) adapted from [37] . Simulation of the proposed DGDMFET with the conceptual discussion clearly shows the significance of using a dual gate. Figure 5 (a)-(e) compares the electron concentration, surface potential, energy, transconductance, and drain current between the proposed device's single gate and dual-gate structure. Figure 5(a) shows that the electron concentration is higher towards the drain side of the channel due to the lesser work function of gate 2. This rise in the electron concentration is because of work function engineering. The increase in surface carrier concentration causes an increase in the surface potential under gate two, as shown in Fig. 5(b) . the influence of work function engineering and performance of the proposed sensor is further analyzed by observing the energy band diagram. In Fig. 5(c) , it can be observed that under gate two, the conduction band and valence band both have a downshift that indicates a higher electron concentration in the specific region. Figure 5 (d) shows that the high electron concentration under the gate2 part results in a higher drain current. The I D versus V GS curve shows that the drain current is better in the dual gate device structure t h a n t h e s i n g l e g a t e d e v i c e s t r u c t u r e . N o w transconductance is also investigated of the proposed biosensor device. It indicates a better transconductance in the case of dual-gate device structure due to better drain current in the same case. From gm curve Fig. 5 (e) , it can be concluded that the sensitivity for virus immobilization of the proposed device with dual gate is higher. The impact of two metal gates, gate 1 (Au) and gate 2 (W), have been analyzed in terms of threshold voltage (V th ) and ON current (I on ). The graphs confirm the better sensitivity of dual gates in comparison to the single gate. The graph of V th sensitivity indicates a significant increase in sensitivity for dualgate, as shown in Fig. 6 (a). Figure 6 (b) also confirms the better sensitivity in terms of ON current. The percentage sensitivity is calculated according to Eq. (4). Some physical characteristics are investigated to show the physics and essential working of the proposed sensor device. We are going to analyze the sensitivity in two cases; in case 1, we considered the dielectric constant as 2.1 and 4.1 because the S-protein of the virus has a dielectric constant in the range between 2 to 4, and in case 2, the dielectric constant considered is in the range between 1 to 64 (DNA detection of virus). Until now, the dielectric constant of the SARS-CoV-2 virus has been unidentified, but it lies in between the range 1 to 64; that is why we are considering the same range for detection purposes. Dielectric constant K = 1(air) is taken as reference for sensitivity calculation, and percentage sensitivity for various parameters is calculated as Eq. 4. [37] Where D = {(V k = 1 ) − (V k = other than 1 )} Value of quantity when dielectric constant K = 1 (air) is occupied in the sensing region is denoted by V k = 1 and V k = Fig. 5 Comparison between the single gate and dual gate structure of proposed biosensor in terms of (a) electron concentrations, (b) ON state surface potential distribution (c) Energy band distribution (EBD), along the lateral length of the device (d) transfer characteristics and (e) transconductance with gate voltage when K = 1(air) is considered inside the cavity Fig. 6 The comparative plot of absolute percentage sensitivity of (a) V th and (b) I on for various dielectric biomolecules Silicon other than 1 is the quantity value when dielectric constant K = 2.1 or 4.1 etc. (dielectric constant of virus protein) is filled in the sensing region. Percentage sensitivity is nothing but sensitivity multiplied by a hundred. Eq. (4) gives the absolute percentage deviation of sensor electrical parameters to air after the virus proteins are immobilized in the nanogap region. Figure 7 represents the physical characteristics along the total device length for various K (2.1, 4.1) . The 7(a) part shows variation in the valence band and conduction band for different dielectric constants; it is clearly seen from the figure that more variations of EBD is under gate 1 (having higher work function), and abrupt change is observed at the junction of the dual gate due to different work function. As the dielectric constant increases, the variation in the energy band diagram for different dielectric constant (K) shows the sensitivity for immobilized protein. The variation in the electric field can also be observed in Fig. 7(b) with various dielectric constants. Figure 7 (c) and (d) show the electron concentration and surface potential variation with different dielectric constants. It is visible that the significant value of electron concentration shows better sensitivity under the cavity, and surface potential is higher under the cavity, which is below gate 2 (W), having a lower work function as compared to gate 1 (Au). Figure 7 (e) is the graph between drain current and gate voltage, indicating a rise in drain current, and this variation shows sensitivity with the virus protein's dielectric constant. Figure 7 (f) shows a small variation in OFF current with an increase in dielectric constant. Figure 8 indicates the sensitivity analysis of the proposed biosensor device. Threshold sensitivity versus dielectric constant is plotted in Fig. 8(a) , which indicates an increasing trend in sensitivity with the increase in dielectric constant. To decide the sensitivity of the proposed device, one of the critical parameters is the threshold voltage. In the graph, K = 1 (air) is taken as a reference, so sensitivity is zero when air is filled in the cavity. Figure 8 (a) also indicates a comparative analysis Fig. 8 (a) Comparison of absolute percentage sensitivity of V th in between proposed sensor device and device mentioned in reference [37] . Variation in absolute percentage sensitivity of (b) subthreshold swing (SS), (c) I on , and (d) transconductance for different virus protein dielectric constant Fig. 9 (a) Comparison of absolute percentage sensitivity of V th in between proposed sensor device and device mentioned in reference [37] with respect to DNA dielectric constant biomolecules. Variation in absolute percentage sensitivity of (b) SS, (c) I on , and (d) transconductance for various DNA dielectric constant of the virus between two sensor devices. One with a red color line is the device mentioned in reference [37] , and the blue color line is used for the proposed sensor device. From the graph, it is clearly observed that the proposed sensor device shows significant improvement in sensitivity as compared with the reference one. Figure 8(b) , (c) and (d) represent variation in sensitivity of subthreshold slope on current and transconductance with the dielectric constant of virus protein (2.1, 4.1) . The use of a Dual metal gate with Cr 2 O 3 improves the ON current sensitivity, which leads to a rise in gm sensitivity, as shown in Fig. 8(c) As discussed in the introduction, the second methodology used for SARS-CoV-2 virus detection is detecting through DNA; for this purpose, the DNA of the virus is converted from RNA. The SARS-CoV-2 dielectric constant is still vague, but the range of the dielectric constant is 1 to 64 [30] . The parameters are examined in terms of the DNA of the virus and found a great amount of sensitivity. Figure 9 . (a) shows a continuous increase with the DNA of virus protein; in the same figure, the proposed sensor device shows far better sensitivity than the reference biosensor device. Figure 9 (b) plot of subthreshold sensitivity with DNA dielectric of virus protein shows an increasing pattern. After K = 32, the graph shows a minimal increase for higher K of the virus. An improved coupling between the channel and the gate voltage is provided by a high K value, due to which ON current sensitivity is showing an increasing trend as plotted in Fig. 9 (c). RF parameter gm also indicates an increase in sensitivity with DNA dielectric of virus protein, as plotted in Fig. 9 (d). The ATLAS device simulator is used for this simulation of the proposed device [38] . The sensing ability of the biosensor proposed in this paper is attained with the conclusive effect of the dual gate and use of Cr 2 O 3 oxide layer by keeping the Si-SiO 2 interface charge density around 1.0 × 10 11 cm −2 . The removal of the insulating gate layer from both the source and drain side partially creates more cavity space for biomolecules immobilization. The internal physics of the proposed biosensor is given by using various DC parameters for optimization. An investigation of the proposed biosensor with the single and dual gate in terms of DC parameters is analyzed, revealing a better result for the double gate. The proposed biosensor shows a 12% increase in threshold sensitivity for the dielectric constant of virus protein K = 4.1 as compared with the previously reported sensor [37] , which discloses that the proposed biosensor has better sensitivity than the several previously reported FET biosensors. From the analysis, it can be concluded that the proposed DGDMFET biosensor will have the capability to detect various protein molecules like cancer markers, DNA, and antibodies. Authors Contribution All authors contributed to the study's conception and design. Material preparation, data collection, and analysis were done by Saurabh Kumar, R.K.Chauhan, and Manish Kumar. The first draft of the manuscript was written by Saurabh Kumar, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript. Data Availability This manuscript has no associated data. Ethics Approval The author has followed all ethics standards Conflict of Interest The authors have no conflicts of interest to declare that are relevant to the content of this article. Covid-19 -navigating the uncharted Trends and innovations in biosensors for COVID-19 mass testing Identification of a novel coronavirus in patients with severe acute respiratory syndrome Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia Characterization of spike glycoprotein of SARS-CoV-2 on virus entry and its immune cross-reactivity with SARS-CoV Evidence of SARS-CoV-2 infection in returning travelers from Wuhan, China A familial cluster of infection associated with the 2019 novel coronavirus indicating possible person-to-person transmission during the incubation period Potential Neuroinvasive Pathways of SARS-CoV-2: Deciphering the spectrum of neurological deficit seen in coronavirus disease-2019 (COVID-19) P-FAB: a Fiberoptic biosensor device for rapid detection of COVID-19 Emergency Preparedness and Response CDC Emergency Operations Center Activations Molecular diagnosis of a novel coronavirus (2019-nCoV) causing an outbreak of pneumonia The role of biosensors in coronavirus disease-2019 outbreak Accelerated Emergency Use Authorization (Eua) Summary Covid-19 Elisa Igg Antibody Test Smart Detect SARS-CoV-2 rRT-PCR Kit Instructions for Use for Emergency Use Authorization (EUA) Ion-sensitive field-effect transistor for biological sensing Comparative study of field effect transistor based biosensors Reconfigurable FET biosensor for a wide detection range and electrostatically tunable sensing response Field-effect transistor biosensors for biomedical applications: recent advances and future prospects Biosensing based on field-effect transistors (FET): recent progress and challenges Performance evaluation of dielectrically modulated extended gate single cavity InGaAs/Si HTFET based label-free biosensor considering non-ideal issues Investigating the performance of short gate insulator less dielectrically modulated tunnel field effect transistor based bio-sensors Complex dielectric constant of various biomolecules as a function of wavelength using surface plasmon resonance Recessed-Channel structure for fabricating ultrathin SOI MOSFET with low series resistance Body-contacted SOI MOSFET structure with fully bulk CMOS compatible layout and process A low-voltage, lowpower microwave SOI MOSFET Structural and optical characterization of Cr 2 O 3 nanostructures: evaluation of its dielectric properties Novel dielectricmodulated field-effect transistor for label-free DNA detection Performance analysis of feedback fieldeffect transistor-based biosensor Enhanced sensitivity of double gate junctionless transistor architecture for biosensing applications On the electrostatic component of protein-protein binding free energy Structural and functional properties of SARS-CoV-2 spike protein: potential antivirus drug development for COVID-19 Dual work function CMOS gate technology based on metal interdiffusion A dielectric-modulated field-effect transistor for biosensing A dielectric modulated biosensor for SARS-CoV-2 ATLAS user's manual, SILVACO Int Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations