key: cord-0075228-h2bkao8t authors: Salthammer, Tunga; Fauck, Christian; Omelan, Alexander; Wientzek, Sebastian; Uhde, Erik title: Time and spatially resolved tracking of the air quality in local public transport date: 2022-02-28 journal: Sci Rep DOI: 10.1038/s41598-022-07290-5 sha: ec4c04f814040ef47a662d1ed88d7afa9775ef7a doc_id: 75228 cord_uid: h2bkao8t As an indoor environment, public transport is subject to special conditions with many passengers in a comparatively small space. Therefore, both an efficient control of the climatic parameters and a good air exchange are necessary to avoid transmission and spread of respiratory diseases. However, in such a dynamic system it is practically impossible to determine pathogenic substances with the necessary temporal and spatial resolution, but easy-to-measure parameters allow the air quality to be assessed in a passenger compartment. Carbon dioxide has already proven to be a useful indicator, especially in environments with a high occupancy of people. Airborne particulate matter can also be an important aspect for assessing the air quality in an indoor space. Consequently, the time courses of temperature, relative humidity, carbon dioxide and particulate matter (PM(10)) were tracked and evaluated in local public transport buses, trams and trains in the Brunswick/Hanover region. In all measurements, the climatic conditions were comfortable for the passengers. Carbon dioxide was strongly correlated with occupancy and has proven to be the most informative parameter. The PM(10) concentration, however, often correlated with the dynamics of people when getting on and off, but not with the occupancy. Sensors, equipped with integrated GPS, were installed in the passenger cabins and were found to be useful for recording location-related effects such as stops. The results of this study show that the online recording of simple parameters is a valuable tool for assessing air quality as a function of time, location and number of people. When the occupancy is high, a low carbon dioxide level indicates good ventilation, which automatically reduces the risk of infection. It is therefore recommended to take more advantage of low-cost sensors as a control for air conditioning systems in passenger cabins and for evaluations of the dynamics in public transport. The determination of the particle concentration, especially PM 10 , is also an important aspect for evaluating the air quality in an indoor space 28, 29 . Boniardi et al. 30 measured multiple air pollutants to compare exposure when commuting by car, public transport and bike. In this work the results of measurements for climatic parameters (temperature and relative humidity), carbon dioxide (CO 2 ) and particles (PM 10 ), carried out in public transport areas in the area of Brunswick/Hanover, Germany, are presented and discussed. In the course of the project, space-saving sensors were developed with which the air quality in the passenger areas can not only be monitored online efficiently, but also record locationrelated effects such as stops and train stations using integrated GPS. Measuring devices. Hand-held devices (Rotronic Messgeräte GmbH, Model CP11) were used to measure temperature T (°C), relative humidity RH (%) and CO 2 (ppm). The time resolution is 10 s. The measuring ranges are − 20 °C to + 60 °C (temperature), 0.1% to 99.95% (relative humidity) and 0 ppm to 5000 ppm (CO 2 ). The measuring principle for CO 2 is non-dispersive infrared (NDIR). An Optical Particle Sizer (TSI Inc. Model 3330) was used to measure the particle concentration. The measuring range is 0.3 µm to 10 µm with a size resolution of 16 channels. The time resolution is 20 s. The device measures the particle number concentration by means of light scattering. The conversion to mass-related concentrations is based on the assumption of spherical particles and a density of 1 g/cm 3 . The measurement of PM 2.5 and PM 10 is particularly important for exposure and healthrelated studies. Since this is only about the dynamics of particles, PM 10 is used as the measurement parameter. PM 10 refers to the mass-related sum of particles with an aerodynamic diameter < 10 µm, whereby a separation efficiency of 50% is assumed for the 10 µm fraction 31 . Moreover, the high fluctuations in the concentrations of the smaller particle fractions did not allow any conclusions to be drawn. The results described here were obtained in the middle of the passenger cabins. Sampling took place at a height of 1.5 m. Further measurements were carried out near the entry and exit doors, but the results were not significantly different. According to the operators, the ventilation systems were set for high performance and a high proportion of fresh air. This indicates a quick and even distribution of the air constituents. For the background concentrations of PM 10 , data were retrieved from the following stations of the Lower Saxony Air Monitoring Network (LÜN): DENI011 (Brunswick, urban background) and DENI054 (Hanover, urban background). The data were analyzed with OriginPro, Version 2021b (OriginLab Corporation, Northhampton, MA). A portable, battery driven monitoring system was also used for the recording of environmental parameters. The system consisted of a SCD30 NDIR CO 2 sensor, a SPS30 optical particle sensor (both Sensirion AG, Staefa, Switzerland), a BME280 temperature/humidity/pressure sensor (Bosch Sensortec GmbH, Reutlingen, Germany), and a SAM-M8Q GNSS antenna module (U-Bloxx, Thalwil, Switzerland). The measurements and the position data were logged in 11 s intervals to a SD memory card using a SAMD21 microcontroller (Microchip Technology Inc., Chandler, USA). The particle sensor measures PM 1 , PM 2.5 , and PM 10 with a resolution of 1 µg/m 3 , but also outputs particle number concentrations for the respective size bins. The CO 2 sensor has a resolution of 30 ppm CO 2 and is corrected for temperature deviations by an onboard temperature sensor. The temperature/pressure/humidity sensor has an accuracy of ± 0.5 °C, ± 2 hPa and ± 3% RH, respectively. Measuring program. The research program focused on regional traffic in Brunswick (Braunschweig) and Hanover, or between the two cities. All measurements were carried out between December 2020 and March 2021, always from the first to the last station. This was done in consultation and with the approval of the respective operator, Braunschweiger Verkehrs GmbH (BSVG), WestfalenBahn GmbH (WfB), RegioBus GmbH and ÜSTRA Hannoversche Verkehrsbetriebe. All lines considered are summarized in Table 1 . The exact type designations of the vehicles, PM 10 concentrations in the ambient air, in the Brunswick and Hanover Central metro station as well as route maps are shown in the Supporting Information. The occupancy of the passenger area was recorded for all route sections. Since the respective vehicle stops every minute in city traffic, orders of magnitude were specified, which the measuring staff had to indicate by ticking the corresponding stops. Seats: (a) not or little occupied (< 10%); (b) weakly occupied (10-30%); (c) moderately occupied (30-70%); (d) crowded (> 70%). Standing places: (a) not or little occupied; (b) weakly occupied; (c) crowded. For each measurement, the occupancy was recorded by two staff persons who were in the same area but at different locations (in the front section of the cabin and near a door in the middle). In addition, a measurement was carried out on the platform of the ÜSTRA Tram 4 underground station at Hanover Central. In coordination with the operator, routes and times were selected in such a way that, under the given circumstances, a high occupancy rate could be expected, either in the early morning or in the afternoon (see Table 1 ). The large data sets and the sometimes high fluctuations make a comparative presentation of all results difficult. For CO 2 no mean values were calculated for the respective route, as the values fluctuated strongly depending on occupancy. The maximum values are therefore provided for each measurement run in Table 2 and compared with hygiene-based guide values. Maximum values are also presented for temperature and relative humidity with the relative humidity relating to the corresponding temperature. In case of PM 10 , maximum values and arithmetic means are shown in Table 2 were not observed. This also applies to periods more than 70% total occupancy (areas marked in red). The lower temperatures or high humidity at the beginning of the measurement can be assigned to influences of ambient air. With the exception of Runs 01 and 02, each with 19% RH, the relative humidity was in the range of approx. 30% to 40%, which can also be rated as pleasant. With regard to the indoor climate, humans are not very adaptable, because even small temperature fluctuations and air movements can cause thermal discomfort. In particular, the sensation of warmth depends on the physical activity, clothing, air temperature, mean radiation temperature, air speed and humidity. At 20 °C, people find a relative humidity of 40% to 60% pleasant 32 . In buses and trains, 20-22 °C are usually the target values, but drafts are unavoidable due to regular opening of windows and doors. However, the very constant values show that the air conditioning systems of the transport vehicles have effective control technology. No changes could be recorded while the doors were being opened at the bus stops. The outside air temperature on the measurement days was less than 10 °C. When there was a high density of people, a slight but significant increase in the relative humidity was observed. Carbon dioxide. With regard to hygienic aspects, the carbon dioxide concentration in the room air serves as an indicator for air deterioration caused by human activity. The concept of the German Committee on Indoor Guide Values regards CO 2 concentrations of less than 1000 ppm (0.1 vol%) as hygienically harmless and CO 2 concentrations higher than 2000 ppm as hygienically unacceptable 33 . In rooms with a high density of people like school classrooms, the carbon dioxide concentration can serve as a guide for good or bad ventilation 27 . Carbon dioxide has also long been regarded as a reliable indicator for the air exchange rate. A CO 2 concentration of at most 1000 ppm indicates a hygienically adequate air exchange under normal living conditions. This means that information can be provided quickly and easily as to whether and when ventilation is necessary. However, this does not mean that a CO 2 concentration of less than 1000 ppm generally protects against infection. On the other hand, CO 2 concentrations significantly or permanently higher than 1000 ppm indicate inadequate ventilation management with a potentially increased risk of infection. During light physical activity, an adult emits approximately 18-24 l/h CO 2 34 . The ambient air concentration of CO 2 in urban areas is approximately 400 ppm. A standard articulated bus has an internal volume of around 120 m 3 . In order to keep the CO 2 concentration permanently below 1000 ppm with an occupancy of 50 people and . It can thus be estimated that the fresh air supply must be at least 10 l /s /p (liters per second and person). As can be seen from Figs. 1B and 2B, the carbon dioxide concentration correlates, as expected, with the density of people in the passenger cabin. Figure 1B represents Run 03 in the BSVG Tram 3 in the early morning. In the section marked in red there was a large number of students on the tram (occupancy > 70%) and the carbon dioxide concentration reached a maximum value of 1197 ppm. The measurement shown in Fig. 2B was also carried out in the early morning on the WestfalenBahn (Run 12). From Lehrte, the last stop before Hanover Central, the train was heavily frequented by commuter traffic, which led to a CO 2 concentration of 1151 ppm. However, these values are only slightly above the guide value for harmless concentrations of 1000 ppm, and far below the value of 2000 ppm, from which unacceptable conditions prevail. The other measurements led to similar results (see Table 2 ). It can therefore be concluded that the ventilation systems in the passenger cabins work efficiently. The ambient air concentrations of CO 2 were in all cases in the range of 400 ppm. Kwon et al. 35 carried out measurements in the metropolitan subway of Seoul, Korea and found CO 2 peak concentrations of more than 4000 ppm during the rush hour. An extensive literature study on CO 2 in passenger cabins of buses and trains was presented by Querol et al. 17 In many cases CO 2 concentrations in the range of 2000-4000 ppm have been reported. Querol et al. 17 see evidence for a lack of ventilation and consequently an increased risk of aerosol COVID-19 transmission. In the same publication, Querol et al. 17 also present the results of CO 2 measurements from 37 public bus trips during rush hour in Barcelona. In this context, scenarios with insufficient ventilation were also examined, which leads to maximum CO 2 contractions of approximately 1800 ppm. Otherwise, despite the different transport systems and metropolises, our CO 2 concentration courses were definitely comparable with their data. Particulate matter. In the case of the particles, the concentration peaks do not necessarily correspond to the occupancy density of the passengers, but often to their dynamics when the doors are regularly opened, combined with getting on and off. Some of the particles are brought in through the ambient air, some through clothing and the movement of passengers. As a result, the particle concentration in the cabin increases significantly at the stations. It was also noticeable that in various measurements the highest particle concentrations were recorded when several passengers boarded at the same time at the starting point. It is known that moving people are relevant particle sources or resuspend particles 36 , but it is certain that the passengers' breathing is not the source of the particles. The maxima occur only for a short time and reach the base level again within a few seconds (see Fig. 3 ). For each measurement run, ambient air measurements were carried out on PM 10 , but only at the respective start and final stations. These concentrations were mostly in the range of 10 µg/m 3 or below (see Supporting Information) and corresponded to the values from urban background stations of the Lower Saxony Air Monitoring Network (LÜN). However, there were bus and train platforms with significantly higher ambient air concentrations of PM 10 . For example, the values in the metro station at Hanover Central are consistently around 50 µg/m 3 (see Supporting Information). At other stations in Brunswick and Hanover, smoking areas on the platforms, traffic or construction sites influenced the PM 10 concentration in the passenger cabins when the doors were open. Therefore, the PM 10 peaks do not always coincide with entry and exit of many people. An example is shown in Fig. 1C , where the highest PM 10 concentrations were measured at a low occupancy density. In Fig. 2C , the sudden increase in PM 10 is due to the boarding of a large number of people at the last station before Hanover Central. The WHO recommends for PM 10 www.nature.com/scientificreports/ well below the WHO guideline. Only at BSVG, Bus Line 419 (Run 09) was a value of this order of magnitude measured at 41.1 µg/m 3 . However, some short-term peak values occurred in individual measurements. The data sets shown in Fig. 3 are part of the complete concentration profile for the respective run, the time ranges are shown in the Supporting Information (Fig. S1 ). The decay curves can also be viewed as representative for other runs. Decay models of various complexity were tested, and the simplest model was selected on the basis of a residual analysis. Figure 3A shows the decay behavior of PM 10 in BSVG line 411 (Run 01). After closing the doors, the PM 10 concentration drops to the ambient air level within 3-4 min. The decay curve follows the mono-exponential time law shown in Eq. (1) very precisely. C(t) is the concentration in the passenger cabin at time t, A is the initial maximum concentration, k 1 is the decay constant and C 0 is the background concentration. Figure 3B shows another scenario for the ÜSTRA line 4 (Run 19) . It is obvious that if the doors are opened frequently the PM 10 concentration hardly decreases. Only after the doors have been closed the PM 10 concentration follows the single exponential decay law. The decay constants are k 1 = 37.7 h −1 for Run 01 and k 1 = 28.8 h −1 for Run 19. These values can be explained by the high air exchange in the passenger cabins, the turbulent transport and the adherence of the particles to surfaces, especially people. In comparison, gravimetric deposition is slow. A spherical particle with a diameter of 10 µm needs approx. 5 min to sink to the ground from a height of 1 m 38 . Sensors. The evaluation of the results so far has shown that carbon dioxide is primarily suitable as an indicator for the air quality in transport cabins when there is a high density of people, as this parameter is directly linked to human breathing and therefore also to other components of the breathing gas. In this respect, a low CO 2 value usually also means good air quality. PM 10 , on the other hand, is linked to personal dynamics. Other parameters, such as the TVOC value (total volatile organic compounds), often measured by photoionization 39 , are not expedient here. Today there are many types of gas and particle sensors available for monitoring indoor air quality, which work reliably and are space-saving at the same time [40] [41] [42] [43] . The mapping of the spatial distribution of air pollutants has proven to be a successful tool for investigating health risks in road traffic 44 . Therefore, in the course of the project, the idea came up of constructing sensors with which the concentration of the respective target parameter can be tracked not only in terms of time but also in terms of location. This provides the operator with valuable information about the number of people at certain times and stops along a route. Figure 4A shows the data from the carbon dioxide sensor along the BSVG Circle Line 419 (Run 09) as a contour plot. This line circles the Brunswick inner city. The sections of the route with an increased number of people are clearly marked by the red areas. BSVG Tram Line 10 shown in Figs. 4B,C passes through Brunswick City from north to south (Run 06) and from south to north (Run 05). Here, the highest occupancy (red areas) can be seen in the city center as expected. The parameters PM 1 and PM 2.5 , which were also measured with the sensors, did not provide any additional information for the issue of efficient ventilation, which is relevant here. There were also some deviations from www.nature.com/scientificreports/ the OPC data, which is due to the measurement technology. In the case of scattered light methods, it is not the size of the individually observed particle that is specified, but the size of a unit particle with the corresponding properties 31 . For example, the short-term PM 10 peaks could not be recorded with the sensor. Moreover, the calibration of particle spectrometers is not traceable. This is different with carbon dioxide, since the sensors can be compared and adjusted with precisely calibrated devices. The comparison between the Rotronic CP11 and the sensor is shown in Fig. 5 for the carbon dioxide concentration at Run 16. Both devices were calibrated against the CO 2 ambient air concentration. The differences in the measurement signals are always less than 10%, which is completely sufficient for this application. The investigations carried out here and the results presented do not claim to assess the risk of persons for an infection by pathogenic bioaerosols in passenger cabins in public transport. It is also explicitly warned against using this methodology for such purposes. Measured values are to be interpreted in such a way that with high occupancy, a low CO 2 concentration implies a high air exchange, which significantly reduces the risk of infection. Conversely, an increased CO 2 concentration indicates an increased risk of infection. It is recommended to choose a CO 2 concentration of 1000 ppm as a criterion 33 , as this value has proven to be suitable for school classes 45 . Querol et al. come to analogous statements and conclude that with an air supply of 14 l/s/p an average CO 2 concentration of 800-900 ppm should not be exceeded. The air supply should also be set in such a way that the basic climatic parameters temperature and relative humidity offer a comfortable thermal environment for the passengers. However, it was demonstrated that the online measurement of simple parameters is a valuable tool for assessing air quality as a function of time, location and number of people. Previous studies have already shown that when occupancy is high, a low carbon dioxide concentration in particular indicates good ventilation, which automatically reduces the risk of infection. It is therefore recommended to take even more advantage of carbon dioxide as a control variable for air conditioning systems in transport cabins. In order to keep the risk of infection as low as possible, a value of 1000 ppm CO 2 should not be exceeded even with high occupancy. Querol et al. 17 suggest tracking the number of people online as well. This allows a person-related optimization of the ventilation conditions while saving fuel or electrical energy at the same time. The measurement can be carried out with low-cost sensors that are permanently installed in the cabin. The additional equipment with GPS also allows further evaluations of the dynamics of public transport. www.nature.com/scientificreports/ Is public transport a risk factor for acute respiratory infection Transmission of SARS-CoV-2 in public transportation vehicles: A case study in Hunan province. China. Open Forum Infect Community outbreak investigation of SARS-CoV-2 transmission among bus riders in Eastern China Transmission by super-spreading event of pandemic A/H1N1 2009 influenza during road and train travel Air and surface measurements of SARS-CoV-2 inside a bus during normal operation Reductions in commuting mobility correlate with geographic differences in SARS-CoV-2 prevalence in New York City Risk of Coronavirus Disease 2019 Transmission in train passengers: An epidemiological and modeling study Transmission of pandemic influenza A (H1N1) virus in a train in China Risk of transmission of airborne infection during train commute based on mathematical model Tracing surface and airborne SARS-CoV-2 RNA inside public buses and subway trains COVID-19 outbreak on the Diamond Princess cruise ship: Estimating the epidemic potential and effectiveness of public health countermeasures Calculating the potential for within-flight transmission of influenza A (H1N1) Routes of transmission of influenza A H1N1, SARS CoV, and norovirus in air cabin: Comparative analyses Logistic growth of a surface contamination network and its role in disease spread Risk assessment of airborne infectious diseases in aircraft cabins Transport of expiratory droplets in an aircraft cabin How can ventilation be improved on public transportation buses? Insights from CO 2 measurements The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles? Airborne transmission of SARS-CoV-2: The world should face the reality It is time to address airborne transmission of coronavirus disease 2019 (COVID-19) The roles of transportation and transportation hubs in the propagation of influenza and coronaviruses: a systematic review Effects of air temperature and relative humidity on coronavirus survival on surfaces Humidity-dependent decay of viruses, but not bacteria, in aerosols and droplets follows disinfection kinetics Relationship between humidity and influenza a viability in droplets and implications for influenza's seasonality Survival of the enveloped virus phi6 in droplets as a function of relative humidity, absolute humidity, and temperature Influence of wind and relative humidity on the social distancing effectiveness to prevent COVID-19 airborne transmission: A numerical study Children's well-being at schools: Impact of climatic conditions and air pollution Indoor aerosols: From personal exposure to risk assessment Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure Commuting by car, public transport, and bike: Exposure assessment and estimation of the inhaled dose of multiple airborne pollutants The German approach to regulate indoor air contaminants Carbon dioxide generation rates for building occupants Study on the indoor air quality of Seoul metropolitan subway during the rush hour Clothing as a transport vector for airborne particles: Chamber study Ozone, Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide. (World Health Organization Aerosol Technology 2nd edn Real-time monitoring of indoor organic compound The rise of low-cost sensing for managing air pollution in cities Indoor air quality and energy management through real-time sensing in commercial buildings Real-time sensors for indoor air monitoring and challenges ahead in deploying them to urban buildings Exposures to multiple air pollutants while commuting: Evidence from Zhengzhou Mapping spatial distribution of traffic induced criteria pollutants and associated health risks using kriging interpolation tool in Delhi Ventilation concepts in schools for the prevention of transmission of highly infectious viruses (SARS-CoV-2) by aerosols in indoor air This work was partially funded by the German Center for Rail Traffic Research at the Federal Railway Authority under Project Number 2020-33-S-1202. The sensor measurements were financed by research funds from the Fraunhofer WKI. T.S.: conceptualization, investigation, formal analysis, writing-original draft, project administration, funding acquisition; C.F.: investigation, writing-review and editing; A.O.: investigation, writing-review and editing; S.W.: methodology, investigation, data curation, formal analysis, writing-review and editing; E.U.: methodology, software, writing-review and editing, data curation, visualization. Open Access funding enabled and organized by Projekt DEAL. The authors declare no competing interests. Supplementary Information The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-07290-5.Correspondence and requests for materials should be addressed to T.S. Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.