key: cord-0074629-ntik78be authors: Ahmed, Warish; Smith, Wendy J. M.; Metcalfe, Suzanne; Jackson, Greg; Choi, Phil M.; Morrison, Mary; Field, Daniel; Gyawali, Pradip; Bivins, Aaron; Bibby, Kyle; Simpson, Stuart L. title: Comparison of RT-qPCR and RT-dPCR Platforms for the Trace Detection of SARS-CoV-2 RNA in Wastewater date: 2022-01-28 journal: ACS ES T Water DOI: 10.1021/acsestwater.1c00387 sha: 213ddd6dbef48a3da934d87592ac7d62b2e3937d doc_id: 74629 cord_uid: ntik78be [Image: see text] We compared reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and RT digital PCR (RT-dPCR) platforms for the trace detection of SARS-CoV-2 RNA in low-prevalence COVID-19 locations in Queensland, Australia, using CDC N1 and CDC N2 assays. The assay limit of detection (ALOD), PCR inhibition rates, and performance characteristics of each assay, along with the positivity rates with the RT-qPCR and RT-dPCR platforms, were evaluated by seeding known concentrations of exogenous SARS-CoV-2 in wastewater. The ALODs using RT-dPCR were approximately 2–5 times lower than those using RT-qPCR. During sample processing, the endogenous (n = 96) and exogenous (n = 24) SARS-CoV-2 wastewater samples were separated, and RNA was extracted from both wastewater eluates and pellets (solids). The RT-dPCR platform demonstrated a detection rate significantly greater than that of RT-qPCR for the CDC N1 and CDC N2 assays in the eluate (N1, p = 0.0029; N2, p = 0.0003) and pellet (N1, p = 0.0015; N2, p = 0.0067) samples. The positivity results also indicated that for the analysis of SARS-CoV-2 RNA in wastewater, including the eluate and pellet samples may further increase the detection sensitivity using RT-dPCR. The emergence and spread of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) have highlighted the utility of wastewater surveillance for early identification of infection in communities and guidance of public health measures to reduce transmission risks. 1−5 Wastewater surveillance of SARS-CoV-2 RNA has been employed in at least 55 countries to monitor the presence and support management of COVID-19 in various communities. 6−17 This approach uses a series of complex environmental microbiology procedures ranging from wastewater sampling to the detection and quantification of viral RNA primarily via polymerase chain reaction (PCR)-based or loop-mediated isothermal amplification (LAMP) assays. 6, 8, 18 These procedures require careful optimization to maximize their sensitivity for detecting traces of SARS-CoV-2 in wastewater, especially in the absence of standard methods. 19−21 Trace detection, the reliable detection of minuscule amounts of RNA in wastewater, is crucial for regions with few COVID-19 cases and for jurisdictions in which elimination is a management strategy. Reverse transcription-quantitative PCR (RT-qPCR) has been employed as a gold standard method for detecting and quantifying SARS-CoV-2 RNA in both clinical and environmental samples. 6, 21, 22 However, several factors can result in quantification bias, as RT-qPCR assays rely on calibration (i.e., standard) curves constructed using a dilution series of the defined number of target molecules (i.e., plasmid DNA, PCR amplicons, synthetic nucleic acid, genomic DNA, and cDNA), typically having five or six dilution points (10-fold each) with at least three replicates per point. 19 Variations in protocols, reagents, sample quality, instruments (e.g., ultraviolet spectrophotometers, PCR platforms, and sample homogenizers), data analysis, software, and interpretation within and across laboratories can lead to the inaccurate and unreliable quantification of SARS-CoV-2 RNA in wastewater. 21, 22 In addition, RT-qPCR amplification may be affected by wastewater samples that often contain inhibitors, such as pharmaceuticals, personal care products, household detergents, industrial effluents, and metals. 24, 25 These compounds can influence the efficiency of RT-qPCR amplification and the subsequent detection and quantification. 26 Some of the limitations of RT-qPCR may be overcome using digital PCR (dPCR). The dPCR platform provides absolute quantification through limiting dilution and most-probable number techniques premised on Poisson statistics rather than a calibration curve. 27, 28 This leads to the improved repeatability and accuracy of quantified target molecules. Compared to qPCR/RT-qPCR in many applications, dPCR has achieved greater analytical sensitivity for detecting various target molecules in both environmental and clinical samples. 29, 30 dPCR is also more resilient to inhibition than qPCR as observed for clinical samples, including feces, and environmental samples, including soil, water, and wastewater. 26,31−33 As a result, the dPCR platform could be ideally suited for the sensitive detection of SARS-CoV-2 RNA in complex wastewater matrices. 34−38 The results from testing of clinical samples for SARS-CoV-2 RNA indicate RT-dPCR can be more accurate in diagnosing COVID-19 than RT-qPCR, and such results are promising for the application of dPCR in wastewater surveillance. 39−43 Compared to the numerous studies using RT-qPCR, a limited number of studies have reported the application of RT-dPCR platforms for the detection of SARS-CoV-2 RNA in wastewater. 38,44−49 Ciesielski et al. 45 demonstrated that RT droplet digital PCR (ddPCR, Bio-Rad) was not influenced by potential PCR inhibitors in wastewater matrices and frequently demonstrated greater analytical sensitivity, yielding fewer falsenegative results compared to RT-qPCR. Boogaerts et al. 47 compared RT-qPCR and RT-dPCR (QIAcuity, Qiagen) for the detection of SARS-CoV-2 RNA in eight untreated wastewater samples in Belgium and reported that the results were comparable. Conversely, D'Aoust et al. 46 reported poorer performance of RT-ddPCR (Bio-Rad) than of RT-qPCR when used for the detection of SARS-CoV-2 RNA in influent post grit and solids and primary clarified sludge samples. In this study, we compared RT-qPCR and RT-dPCR for the trace detection of SARS-CoV-2 RNA in 96 wastewater samples from low-prevalence COVID-19 locations in Queensland, Australia. Additionally, a subset (n = 24) of wastewater samples that had previously tested negative for SARS-CoV-2 RNA were seeded with known concentrations of SARS-CoV-2 to determine RT-qPCR and RT-dPCR detection sensitivity. We also identify and discuss advantages and disadvantages that RT-dPCR may offer over RT-qPCR for trace detection of SARS-CoV-2 RNA in wastewater. Wastewater Samples. Wastewater samples used in this study were from the Queensland's wastewater surveillance program for SARS-CoV-2 (https://www.qld.gov.au/health/ conditions/health-alerts/coronavirus-covid-19/current-status/ wastewater). In total, 96 untreated wastewater samples that had been collected between June 7, 2021, and June 14, 2021, from 45 wastewater treatment plants (WWTPs) across Queensland, Australia, were selected. Automated samplers operating in time proportional mode (every 15 min for 24 h) were used to collect 500 mL to 1 L composite wastewater samples. 4 SARS-CoV-2 Concentration and Extraction. Before primary concentration, each wastewater sample was seeded with a known number of murine hepatitis virus (MHV) as an RNA extraction positive control. SARS-CoV-2 was concentrated from 50 mL of the wastewater samples using a rapid concentrator pipet instrument (Concentrating Pipette Select, CP Select, InnovaPrep, Drexel, MO) designed for concentrating bacteria, protozoa, and viruses from water matrices simultaneously. 50, 51 Prior to the concentration step, the wastewater sample was first centrifuged at 3000g for 5 min to pellet the suspended solids (Avanti J-15R Centrifuge, Beckman Coulter). The supernatant (∼49 mL) was then concentrated with the CP Select using an unirradiated 0.05 μm PS hollow fiber filter concentrating pipet tip (catalog no. CC08004-200), following the optimized wastewater application settings provided in the instrument instructions. Following concentration, the pipet tip was eluted twice using CP elution fluid (HC08001) containing 0.075% Tween 20 and 25 mM Tris (catalog no. HC08001). The eluate (0.7−0.8 mL) was collected in sterile 15 mL polypropylene tubes. Four concentration method negative controls were included to identify potential contamination during sample concentration using the CP Select. Immediately after concentration, RNA was extracted from an aliquot of 140 μL of the eluate using the QIAamp Viral RNA Mini Kit (catalog no. 52905, Qiagen) with a minor modification. In the final step, a 100 μL volume of buffer AVE was used to elute the RNA instead of 60 μL to have sufficient RNA samples for downstream analysis. RNA (100 μL of eluate) was also extracted directly from the 50−140 mg wet mass pellet (separated during the initial centrifugation step) using the RNeasy Power Microbiome Kit (Qiagen) according to the manufacturer's instructions. The pellet was included because our previous study reported the partitioning of SARS-CoV-2 in the eluate and pellets from wastewater. 50 Four RNA extraction negative controls were included to identify potential contamination during RNA extraction. All RNA samples were stored at −20°C for 24 h and subjected to RT-qPCR and RT-dPCR analysis at the same time to minimize nucleic acid degradation. RT-qPCR Analysis. Previously-published RT-qPCR assays targeting the N gene of SARS-CoV-2 (CDC N1 and CDC N2) were used for SARS-CoV-2 RNA detection and quantification. 52 The primer and probe sequences, along with cycling parameters for all of the RT-qPCR assays used, including MHV, are shown in Supplementary Table ST1 . RNA extracted from γ-irradiated SARS-CoV-2 hCoV 19/Australia/VIC01/ 2020 using a QIAamp Viral RNA mini kit was quantified with RT-dPCR and used as the RT-qPCR standard for both CDC N1 and N2 assays. CDC N1 and CDC N2 standard dilutions ranged from 1 × 10 6 to 1 gene copy (GC)/μL of template RNA. For MHV, gBlock gene fragments were purchased from Integrated DNA Technologies (Integrated DNA Technology, Coralville, IA) and used as a positive control. MHV and SARS-CoV-2 N gene assays were performed in 20 μL reaction mixtures using TaqMan Fast Virus 1-Step Master Mix (Applied Biosystems). The MHV RT-qPCR mixture contained 5 μL of Supermix, 300 nM forward primer, 300 nM reverse primer, 400 nM probe, and 5 μL of template RNA. The CDC N1 and N2 RT-qPCR mixtures contained 5 μL of Supermix, 2019-nCoV Kit (500 nM forward primer, 500 nM reverse primer, and 125 nM probe) (catalog no. 10006606), and 2.5 μL of template RNA. Four RT-qPCR replicates were used for each sample. The RT-qPCR assays were performed using a Bio-Rad CFX96 thermal cycler (Bio-Rad Laboratories, Richmond, CA), using automatic settings for the threshold and baseline. The experiments were performed using triplicate PCR negative and positive (γ-irradiated SARS-CoV-2 RNA) controls. To minimize RT-qPCR contamination, RNA extraction and RT-qPCR setup were performed in separate laboratories. RT-dPCR Analysis. The CDC N1 and N2 assays were optimized for primer and probe concentrations and annealing temperature and time. Using the optimized conditions, CDC N1 and N2 assays were performed in 40 μL reaction mixtures using the QIAcuity One-Step Viral RT-PCR Kit (catalog no. 1123145, Qiagen) and 26000 24-well Nanoplates (catalog no. 250001, Qiagen). The 26000 QIAcuity 24-well Nanoplates are microfluidic dPCR plates that enable 24 samples to be run with up to 26000 partitions/well. The PCR occurs in each partition, and the partition volume is 0.91 nL. The CDC N1 and N2 RT-dPCR mixture contained 10 μL of master mix, 800 nM forward primer, 800 nM reverse primer, 200 nM probe, 0.4 μL of 100× Multiplex Reverse Transcription Mix, 19.2 μL of DNase and RNase free water, and 5 μL of template RNA. Two RT-dPCR replicates were used for each sample. The 40 μL RT-dPCRs were prepared in a 96-well preplate and then transferred into the 26000 24-well Nanoplates. The nanoplate was then loaded onto the QIAcuity dPCR 5-plex platform (Qiagen) and subject to an automated workflow that included (i) a priming and rolling step to generate and isolate the chamber partitions, (ii) an amplification step using the thermal cycling protocol (50°C for 40 min for reverse transcription, 95°C for 2 min for enzyme activation, 95°C for 5 s for denaturation, and 60°C for 90 s for annealing/extension for 45 cycles), and (iii) a final imaging step made by reading in the FAM channel. The experiments were performed using duplicate RT-dPCR negative and positive (γ-irradiated SARS-CoV-2 RNA) controls. To minimize RT-dPCR contamination, RNA extraction and RT-dPCR setup were performed in separate laboratories. Data were analyzed using the QIAcuity Suite Software version 1.1.3 193 (Qiagen), and quantities expressed as GC per microliter of reaction mixture. The RT-dPCR assays were performed using automatic settings for the threshold and baseline. RT-qPCR and RT-dPCR ALODs. To determine CDC N1 and N2 RT-qPCR and dPCR assay limits of detection (ALODs), γ-irradiated SARS-CoV-2 was diluted and analyzed using RT-qPCR and RT-dPCR. At each dilution, 15 replicates were analyzed. The ALOD was defined by fitting a cumulative Gaussian distribution to the observed proportion of positive technical replicates along the dilution series. The 95% ALOD was estimated as the 95th percentile of the resulting normal distribution. 48 SARS-CoV-2 Seeding Experiments. Because the wastewater samples were collected from low-prevalence COVID-19 regions, a subset of samples (n = 24) confirmed negative for SARS-CoV-2 by RT-qPCR/dPCR during initial analysis were seeded with γ-irradiated SARS-CoV-2. γ-Irradiated SARS-CoV-2 hCoV-19/Australia/VIC01/2020 was provided by the Australian Centre for Disease Preparedness, CSIRO. γ-Radiation was administered with a 50 kiloGy or 5 Mrad dose using an MDS Nordion Irradiator to mitigate the risk of infection associated with handling infectious SARS-CoV-2 in a biosecurity containment level 2 (BC2) laboratory, where the study was conducted. Among the 24 wastewater samples, 12 samples (WW 1−WW 12) were seeded with 2.83 × 10 4 ± 3.80 × 10 3 GC/50 mL and the remaining 12 samples (WW 13− WW 24) were seeded with 1.67 × 10 5 ± 9.71 × 10 3 GC/50 mL. After seeding, primary concentration, RNA extraction, and RT-qPCR/dPCR detections were performed according to the methods described above. PCR Inhibition Test Assessment. The presence of PCR inhibition was assessed for a subset (n = 20) of the 96 RNA extracts (20.8%) that yielded negative results (no detection) during initial testing by RT-qPCR. These extracts were seeded with a known number of γ-irradiated SARS-CoV-2 for RT-qPCR (1.0−1.2 × 10 3 GC/reaction) and for RT-dPCR (2.0− 2.4 × 10 3 GC/reaction). The concentration of the γ-irradiated SARS-CoV-2 stock was determined using dPCR as described above. The SARS-CoV-2 CDC N1 assay was used to assess PCR inhibition by comparing Cq values (for RT-qPCR) and absolute concentrations (for RT-dPCR) of seeded extracts with reference values from DNase and RNase free water seeded with the same numbers of SARS-CoV-2. CDC N1 RT-qPCR and RT-dPCR assays were performed as described previously. All samples were analyzed alongside three RT-qPCR/RT-dPCR negative controls. For RT-qPCR, if the Cq value of the RNA sample was >2 Cq values compared to the reference Cq value for distilled water, the sample was considered to have PCR inhibitors. 53, 54 For RT-dPCR, if the concentrations of SARS-CoV-2 RNA in seeded wastewater samples were 4-fold lower than the benchmark concentrations, the sample was considered inhibited. Data Analysis. For RT-qPCR, samples were considered positive (SARS-CoV-2 detected) if amplification was observed in at least one of the four replicates. Samples were considered quantifiable by RT-qPCR if amplification was observed for all four replicates and the mean concentration was above the ALOD. Samples were considered negative (10000. 45 Samples were considered negative (100 mL) of wastewater may make the effects of PCR inhibitors more pronounced. For the detection of endogenous SARS-CoV-2 RNA in wastewater samples, both the eluate and the pellet, RT-dPCR achieved a detection rate greater than that of RT-qPCR using the CDC N1 and N2 assays. These results corroborate the greater analytical sensitivity of RT-dPCR suggested by the ALOD determination in this study. We also noted that CDC N1 RT-qPCR yielded more positive results than CDC N2 RT-qPCR, which is consistent with the analytical sensitivity observed during the assay development. 57 However, CDC N2 RT-dPCR detection rates were slightly lower than CDC N1 RT-dPCR detection rates, suggesting a similar detection sensitivity of RT-dPCR for ambient wastewater samples. Differences in the RT step (10 min for RT-qPCR vs 40 min for RT-dPCR), cycling parameters and master mix may also contribute to the increased sensitivity of RT-dPCR. It has been reported previously that the master mix composition may contribute to qPCR and dPCR assay performance. 58 While it would be ideal to use the same reagents and cycling parameters for comparing RT-dPCR and RT-qPCR, QIAcuity requires a specific master mix with a reference dye for the reliable detection of proper partition filling in the Nanoplates leading to a longer (i.e., 40 min) RT step than RT-qPCR master mix (i.e., 10 min) used in this study. Overall, the concentrations of SARS-CoV-2 measured using RT-dPCR were low, while none of the samples could be quantified using RT-qPCR. This is expected given that the wastewater samples were collected from areas with no observed community transmission other than COVID-19infected individuals in quarantine hotels and hospitals. A subset of 96 wastewater samples tested in this study were previously analyzed with CDC N1 and CDC N2 assays as part of routine surveillance in Queensland, Australia. However, the concentration method (adsorption−extraction) and RNA template (5 μL/reaction) volume were different from those employed in the study presented here (CP method and 2.5 μL/reaction). We compared the RT-qPCR results from the previous analysis with RT-qPCR and RT-dPCR results obtained in the study presented here to consider the possibility that low copy detection of SARS-CoV-2 RNA using dPCR is not an artifact from something such as sensor dust. In addition, the dPCR platform was serviced before this study. A good agreement was found between previously generated RT-qPCR and current RT-dPCR data. All RT-dPCR negative controls were negative in each plate, which suggests that RT-dPCR detections of SARS-CoV-2 RNA were not artifacts. We also seeded known concentrations of γ-irradiated SARS-CoV-2 in wastewater samples that had previously tested negative via RT-qPCR/RT-dPCR to further examine the detection sensitivity of both platforms in the presence of matrix interference. For the low-concentration seeding scenario, the RT-dPCR N1 assay yielded more positive detections for both wastewater eluate and pellet samples compared to the RT-qPCR N1 assay. Similarly, the RT-dPCR N2 assay also yielded two positive results for one eluate and pellet sample, but RT-qPCR did not produce any positive results. Another approach for increasing dPCR analytical sensitivity is to combine several wells into a single well (i.e., hyper-well functionality), which will also be useful for measuring dilute target molecules such as SARS-CoV-2 in wastewater. For high-concentration seeding scenarios, RT-dPCR N1 and N2 assays yielded similar positive detections for wastewater eluate samples compared to RT-qPCR N1 and N2 assays. dPCR detection rates for pellet samples were also greater than RT-qPCR rates. Our seeding experiment results agree with ambient wastewater sample results, suggesting dPCR is more sensitive when the concentration of SARS-CoV-2 RNA is low. At greater concentrations, it is highly likely both platforms will yield similar positive detections. For exogenous SARS-CoV-2 seeded into wastewater, we observed that SARS-CoV-2 RNA was found in both eluate and pellet samples. When the detection rates in eluate and pellet samples were combined, the results were better than individual eluate and pellet detections alone, suggesting that separating pellets from wastewater could result in reduced sensitivity. This is particularly important for trace detection of SARS-CoV-2 for public health purposes. Although RT-dPCR was more sensitive for the detection of SARS-CoV-2 in wastewater samples in the study presented here, there are some disadvantages compared to RT-qPCR. Typically, dPCR platforms and the associated consumables are more expensive than RT-qPCR. Additionally, because of their dependence on Poisson statistics, the quantifiable range for dPCR is much narrower (≤26000 GC/reaction in the study presented here) compared to that of RT-qPCR and may require dilution for target molecules with concentrations of >26000 GC/reaction. Furthermore, RT-dPCR experiments typically require more time (∼3.5 h) than do RT-qPCR experiments (∼1.5 h) and include a manual setup compared to RT-qPCR, which can be set up using a liquid handler. For the QIAcuity platform, the number of samples that were processed per nanoplate (24 samples/well) is only one-quarter of the 96 well plates (96 samples/well), which can greatly limit throughput for large-scale wastewater monitoring programs. However, this limitation may be partially overcome by duplexing or multiplexing SARS-CoV-2 assays, whereas currently two singleplex assays (CDC N1 and CDC N2) are being used for routine wastewater surveillance of SARS-CoV-2. ddPCR measurements of duplex Enterococcus spp. and the human fecal Bacteroides HF183 marker gene were nearly identical to singleplex measurements. 33 Multiplexing could improve RT-dPCR throughput and may lower per analyte costs. Despite these limitations, the results of the study presented here indicate that RT-dPCR offers significantly improved analytical sensitivity over RT-qPCR for the workflow used. Such improved sensitivity will likely be vital for wastewater surveillance in settings with little or no COVID-19 cases in the community. RT-dPCR implemented in this study is a suitable platform for the detection of low levels of SARS-CoV-2 RNA in wastewater samples. The ALODs of both RT-qPCR and RT-dPCR were within the same order of magnitude for γ-irradiated SARS-CoV-2; however, in the presence of a matrix (wastewater), RT-dPCR detection rates outperformed RT-qPCR. Because SARS-CoV-2 RNA was detected in wastewater eluate and pellet samples, SARS-CoV-2 should be concentrated from both liquid and solid phases of wastewater to increase the detection sensitivity. Future research is needed to study the duplexing or multiplexing potential of the QIAcuity platform to save cost and improve throughput. SARS-CoV-2 in wastewater: State of the knowledge and research needs Measurement of SARS-CoV-2 RNA in wastewater tracks community infection dynamics Long-term monitoring of SARS-CoV-2 RNA in wastewater of the Frankfurt metropolitan area in Southern Germany SARS-CoV-2 RNA monitoring in wastewater as a potential early warning system for COVID-19 transmission in the community: A temporal case study Making Waves: Plausible lead time for wastewater based epidemiology as an early warning system for COVID-19 First confirmed detection of SARS-CoV-2 in untreated wastewater in Australia: A proof of concept for the wastewater surveillance of COVID-19 in the community First proof of the capability of wastewater surveillance for COVID-19 in India through detection of genetic material of SARS-CoV-2 Presence of SARS-Coronavirus-2 RNA in sewage and correlation with reported COVID-19 prevalence in the early stage of the epidemic in the Netherlands Preliminary results of SARS-CoV-2 detection in sewerage system in Niteroí municipality Presence and infectivity of SARS-CoV-2 virus in wastewaters and rivers Epidemiological surveillance of SARS-CoV-2 by genome quantification in wastewater applied to a city in the northeast of France: Comparison of ultrafiltration-and protein precipitation-based methods Surveillance of SARS-CoV-2 in sewage and wastewater treatment plants in Mexico Implementing building-level SARS-CoV-2 wastewater surveillance on a university campus Show us the data: Global COVID-19 wastewater monitoring efforts, equity, and gaps Detection of SARS-CoV-2 in raw and treated wastewater in Germany−suitability for COVID-19 surveillance and potential transmission risks Building-level wastewater surveillance using tampon swabs and RT-LAMP for rapid SARS-CoV-2 RNA detection The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments Surveillance of SARS-CoV-2 RNA in wastewater: Methods optimization and quality control are crucial for generating reliable public health information Minimizing errors in RT-PCR detection and quantification of SARS-CoV-2 RNA for wastewater surveillance Reproducibility and sensitivity of 36 methods to quantify the SARS-CoV-2 genetic signal in raw wastewater: findings from an interlaboratory methods evaluation in the US Effectiveness of qPCR permutations, internal controls and dilution as means for minimizing the impact of inhibition while measuring Enterococcus in environmental waters PCR inhibitors -occurrence, properties, and removal Reverse transcriptase droplet digital PCR shows high resilience to PCR inhibitors from plant, soil and water samples High-throughput droplet digital PCR system for absolute quantitation of DNA copy number Absolute quantification by droplet digital PCR versus analog real-time PCR Comparison of droplet digital PCR and quantitative PCR for the detection of Salmonella and its application for river sediments Comparison of droplet digital PCR to real-time PCR for quantification of hepatitis B virus DNA A multiplexed droplet digital PCR assay performs better than qPCR on inhibition prone samples Tolerance of droplet-digital PCR vs. real-time quantitative PCR to inhibitory substances Droplet digital PCR for simultaneous quantification of general and human-associated fecal indicators for water quality assessment Evaluation of a droplet digital polymerase chain reaction format for DNA copy number quantification One-step RT-droplet digital PCR: a breakthrough in the quantification of waterborne RNA viruses Assessment of the direct quantitation of SARS-CoV-2 by droplet digital PCR Detection of SARS-CoV-2 RNA residue on object surfaces in nucleic acid testing laboratory using droplet digital PCR Evaluation of droplet digital PCR for quantification of SARS-CoV-2 Virus in discharged COVID-19 patients ddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens Detection and quantification of SARS-CoV-2 by droplet digital PCR in real-time PCR negative nasopharyngeal swabs from suspected COVID-19 patients Highly accurate and sensitive diagnostic detection of SARS-CoV-2 by digital PCR COVID-19 surveillance in Southeastern Virginia using wastewaterbased epidemiology Assessing sensitivity and reproducibility of RT-ddPCR and RT-qPCR for the quantification of SARS-CoV-2 in wastewater Quantitative analysis of SARS-CoV-2 RNA from wastewater solids in communities with low COVID-19 incidence and prevalence An alternative approach for bioanalytical assay development for wastewater-based epidemiology of SARS-CoV-2. medRxiv Within-day variability of SARS-CoV-2 RNA in municipal wastewater influent during periods of varying COVID-19 prevalence and positivity Wastewater surveillance during mass COVID-19 vaccination on a college campus Comparative analysis of rapid concentration methods for the recovery of SARS-CoV-2 and quantification of human enteric viruses and a sewageassociated marker gene in untreated wastewater Development of a large volume concentration method for recovery of coronavirus from wastewater Novel crAssphage marker genes ascertain sewage pollution in a recreational lake receiving urban stormwater runoff Comparison of virus concentration methods for the RT-qPCR based recovery of murine hepatitis virus, a surrogate for SARS-CoV-2 from untreated wastewater. Sci. Total Environ. 2020, 739, 139960. (55) Fisher, R. On the Interpretation of χ2 from Contingency Tables, and the Calculation of P Passive sampling of SARS-CoV-2 for wastewater surveillance US CDC Real-time reverse transcription PCR panel for detection of severe acute respiratory syndrome coronavirus 2 Variably improved microbial source tracking with digital droplet PCR