key: cord-0072886-paf1qw0v authors: Tan, Teik Hin; Ismail, Rosmadi title: Utility of Lung Perfusion SPECT/CT in Detection of Pulmonary Thromboembolic Disease: Outcome Analysis date: 2022-01-06 journal: Nucl Med Mol Imaging DOI: 10.1007/s13139-021-00726-2 sha: 7503abbdf0e99ee1d716ce7cdbc031484039bc4a doc_id: 72886 cord_uid: paf1qw0v PURPOSE: To evaluate the clinical outcome of Q-SPECT/CT in pulmonary thromboembolic disease. METHODS: From Jan 2020 to Jan 2021, 30 consecutive patients (M:F = 8:22; median age = 52 year (21–89)) suspected of having acute pulmonary embolism (PE) or chronic thromboembolic pulmonary hypertension (CTEPH) were referred for non-contrasted Q-SPECT/CT. All patients were COVID-19 PCR negative. MSKCC Q-SPECT/CT and/or PISAPED criteria were used to determine the presence of thromboembolic disease in Q-SPECT/CT. Final diagnosis was made based on composite reference standards that included at least 2-month clinical cardiorespiratory assessment and follow-up imaging. RESULTS: Q-SPECT/CT was positive in 19 patients: indeterminate in 1 and 10 were negative. Three false positive cases were observed during follow-up. Of the remaining 16 true positives, all patients’ cardiorespiratory symptom were improved or stabilised after treatment with anticoagulants. The overall sensitivity, specificity, PPV, NPV and accuracy of Q-SPECT/CT were 100% (95% CI, 79.41–100%), 78.57% (95% CI, 49.20–95.34%), 84.21% (95% CI, 66.41–93.57%), 100% and 90.00% (95% CI, 73.47–97.89%) respectively. CONCLUSIONS: In the current COVID-19 pandemic, Q-SPECT/CT can be an alternative modality to detect pulmonary thromboembolic disease. Normal Q-SPECT/CT excludes pulmonary thromboembolic disease with high degree of certainty. However, false positive has been observed. Acute pulmonary embolism (PE) is a life-threatening but treatable illness caused by migration of thrombi to the pulmonary circulation. The mortality rate of acute PE can be as high as 30% in untreated patients [1, 2] . Moreover, chronic PE may organise and increase pulmonary vascular resistance, subsequently leading to chronic thromboembolic pulmonary hypertension (CTEPH) [3, 4] . Imaging plays a pivotal role in the diagnosis and management of these patients. Computed tomography pulmonary angiography (CTPA) is commonly used in the workup of suspected acute PE due to readily availability and rapid acquisition time [5, 6] . Ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT) is the second most commonly used modality. V/Q-SPECT has been recently revisited as a standard imaging in evaluating suspected acute PE in young women due to its significantly lower radiation dose to the breast [7, 8] . Moreover, there is almost no contraindication to undergo V/Q-imaging [6] . For acute PE, V/Q scintigraphy has demonstrated strong diagnostic validations in the prospective outcome studies [6] . In the 2019 ECR guidelines, further confirmatory testing is unnecessary when the VQ scintigraphy is normal or shows high probability of PE [6] . For the evaluation of patients with unexplained pulmonary hypertension and CTEPH, V/Q-SPECT is recommended as the procedure of choice [9] . In order to reduce the infectious exposure risk to health care workers in the current COVID-19 pandemics, most nuclear medicine centres have omitted the ventilation component of the V/Q SPECT and substituted it with low-dose CT (LDCT) [10, 11] . Several publications have demonstrated high sensitivities of Q-SPECT and Q-SPECT/CT in evaluation of acute PE and CTEPH [12] [13] [14] [15] [16] . Nevertheless, there are some concerns about the higher reported false positive rate of Q-SPECT/CT when comparing to V/Q SPECT [17] [18] [19] . Furthermore, data on outcome analysis for Q-SPECT/CT is fairly limited. The aim of this study is to evaluate the clinical outcomes of patients with pulmonary thromboembolic disease that underwent Q-SPECT/CT and further strengthen the applicability of Q-SPECT/CT in settings. From Jan 2020 to Jan 2021, patients with suspected acute PE or CTEPH referred for Q-SPECT/CT were recruited. Pulmonary Embolism Rule-out Criteria (PERC) and revised Geneva criteria were used to assess clinical probability in patients suspected to have acute PE [21, 22] . Patients were suspected to have CTEPH if they had unexplained raised pulmonary artery systolic pressure (PASP) or right ventricular systolic pressure (RVSP) on echocardiography. Following clinical assessment, all patients underwent D-dimer, COVID-19 PCR test, chest X-ray (CXR) and/or high-resolution CT (HRCT). Some patients additionally underwent Doppler ultrasound of lower limb veins and CTPA. Patients were then evaluated by Q-SPECT/CT. Exclusion criteria were (1) haemodynamically instability, (2) confirmed PE on CTPA, (3) extensive lung parenchymal abnormality on initial CXR and/or HRCT or (4) positive COVID-19 PCR test. Following Q-SPECT/CT, patients were managed accordingly by the primary chest physician based on the Q-SPECT/CT and other clinical parameters. They were then followed up for at least 2 months with respect to cardiorespiratory status with/without repeated Q-SPECT/CT, CTPA or HRCT. Final diagnosis was made based on these clinico-radiological findings. The flow chart is depicted in Fig. 1 . This study was approved by the institutional ethics review committee. All patients' data and images were deidentified and anonymised before being used as inputs for data processing and analysis. Q-SPECT/CT was performed in accordance with the recommended guidelines and protocols [23] . Patients were administered with 185 MBq of 99mTc-macroaggregated albumin (MAA) (Pulmocis®, IBA). Image acquisition was performed within 5 min post-injection on a dedicated Siemens Symbia Intevo 16. Multiple planar projections were acquired followed by SPECT and free-breathing non-contrasted LDCT. For SPECT acquisition, a general purpose collimator, 128 × 128 matrix, was used. A peak window of 15% width was centred around the 140-keV energy peak. The total number of projections is 32, at 20 s per projection. For CT imaging, 130 kV and 75 mAs/slice were used. Attenuation and scatter correction were performed using CT-based attenuation-corrected maps. SPECT images were reconstructed with an ordered-subset expectation maximisation (OSEM) 3-D algorithm (4 subsets, 4 iterations, 8.40 Gausian filter). CT transverse images were reconstructed at 1.5-mm section thicknesses, using reconstruction kernels of sharp resolution (Siemens B75f). All images were viewed on (Syringo.via workstation; Siemens Healthineers) by an experienced nuclear medicine physician. Segmental map was used when interpreting multiplanar images. All three orthogonal planes of the SPECT, CT and fusion images were viewed. In this study, MSKCC Q-SPECT/CT and/or PISAPED criteria were used to determine the presence of thromboembolic disease in Q-SPECT/CT. By MSKCC Q-SPECT/CT criteria, any wedge-shaped peripheral perfusion defect occupying > 50% of a lung segment without corresponding pulmonary parenchymal or pleural disease was considered positive [24] . In the PISAPED criteria, single or multiple wedgeshaped perfusion defects of any sizes are considered positive [25] . Perfusion defect that did not fulfil the above criteria was classified as indeterminate. The statistical analysis includes sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) calculated using 2 × 2 table and MedCalc calculator. A total of 30 patients (male:female = 8:22; median age = 52 year (range 21 to 89 years)) with suspicion of acute PE or CTEPH were included during the study period (Table 1) . Nineteen out of thirty patients (63.3%) primarily presented with sudden-onset or worsened resting dyspnoea. A diagnosis of acute PE was unable to be excluded based on PERC criteria [13] . Of these 19 patients, 8 patients (41.2%) had predisposing risk factors of PE and classified as intermediate risk following the revised Geneva criteria [14] . Half of the patients (50.0%) demonstrated raised D-dimer levels. Seven patients (36.8%) had CTPA done, 3 of which revealed inconclusive finding of PE and 4 of which were reported as normal (Table 1) . Eleven patients (36.7%) presented with dyspnoea of uncertain origin and demonstrated raised pulmonary artery systolic pressure (PASP) and right ventricular systolic pressure (RVSP) on echocardiography. A diagnosis of CTEPH was suspected in these patients. Out of 19 patients who were suspected to have acute PE, thromboembolic disease was detected by Q-SPECT/CT in 10 patients. Of the 10 patients, 8 were given anticoagulants. Seven of them demonstrated resolution of tachycardia and improvement in dyspnoea during the 2-month follow-up. Complete or partial resolution of perfusion defect(s) were observed on follow-up Q-SPECT/CT (Fig. 2) . Hence, all 7 patients were considered true positive for the diagnosis of acute PE ( Table 2) . The other 3 patients were classified as false positive. In these 3 patients, one patient continued to have dyspnoea despite anticoagulants. Follow-up Q-SPECT/CT showed perfusion defects at hyperexpanded oligaemic lung segments (Fig. 3) . She was finally diagnosed with right coronary artery stenosis on subsequent coronary angiography. The remaining 2 false-positive patients were not treated with anticoagulant. On follow-up, their cardiorespiratory symptom resolved without specific therapy. No follow-up Q-SPECT/CT was performed as it was deemed unnecessary by the chest physician. One patient was eventually diagnosed with cardiac failure. Retrospective review of the Q-SPECT/ CT images revealed upper lobe diversion of 99mTc-MAA with presence of lower lobar perfusion defects (Fig. 3) . The Out of 11 patients who were suspected to have CTEPH, thromboembolic disease was detected by Q-SPECT/CT in 9 patients. All 9 patients received anticoagulants. Five patients demonstrated improved cardiorespiratory symptom during clinical follow-up, whereas 4 patients' status remained stable. As CTEPH patients on long-term anticoagulants are expected to have no further in situ pulmonary artery thrombosis and recurrent venous thromboembolism [26] , these patients were classified as true positive based on clinical disease stabilisation (Table 2 ). Nine patients from suspected acute PE group and 2 patients from suspected CTEPH group demonstrated either negative or indeterminate finding of thromboembolic disease on Q-SPECT/CT ( Table 2) . Out of these 9 patients from acute PE group, 8 patients demonstrated low pre-test clinical probability for thromboembolic disease and were not treated with anticoagulants. Their cardiorespiratory conditions had not deteriorated after 2 months of follow-up. One patient had history of ovarian carcinoma with positive D-dimer and deep vein thrombosis (DVT) on ultrasound. Anticoagulants were prescribed to treat the DVT. The diagnosis of absent PE was confirmed by negative pre-and posttreatment CTPA. In 2 patients from CTEPH group, no anticoagulant was prescribed. Their cardiorespiratory conditions did not deteriorate after 2 months of follow-up. Hence, all 11 patients with negative or indeterminate Q-SPECT/CT were classified as true negatives. The overall sensitivity, specificity, PPV, NPV and accuracy of Q-SPECT/CT were 100% (95% confidence interval (CI), 79. 41 Extensive studies have demonstrated high sensitivity, specificity and NPV of V/Q-SPECT in the evaluation of acute PE, ranging between 96-99%, 96-98% and 97-99% respectively [27] [28] [29] [30] [31] [32] . When CT is added in V/Q SPECT, the specificity increased to 100% and lower non-diagnostic rate is observed [15] . A recent analysis by Toney et al. has demonstrated that V/Q SPECT/CT confers better economic value when compared to CTPA, V/Q SPECT and V/Q planar imaging, primarily via improved sensitivity and specificity and lower nondiagnostic rates [33] . In the diagnosis of CTEPH, V/Q planar imaging and Q-SPECT are reported to have higher sensitivities and equivalent specificities compare to CTPA (96-97% vs 51% and 90-95% vs 99% respectively) [14, 34] . Compared to V/Q-SPECT, Q-SPECT/CT has comparable sensitivity but is reported to have higher false positive rate in PE evaluation [17, 19, 20] . However, such a high false positive rate is not observed in CTEPH [9] . At our institution, appropriate use criteria of PE imaging endorsed by the Society of Nuclear Medicine and Molecular Imaging (SNMMI), the European Association of Nuclear Medicine (EANM), the American Society of Hematology (ASH), the Society of Thoracic Surgeons (STS) and the American College of Emergency Physicians (ACEP) were followed [35] . CTPA remains the primary form of imaging for evaluation of patients with high pre-test probability of acute PE, particularly those with haemodynamic instability. When there is equivocal or suspected small PE on CTPA, Q-SPECT/CT is performed to exclude it. In the case of low or intermediate pre-test probability, Q-SPECT/CT may be used as initial workup imaging in view of high NPV and lower radiation dose, in particular to female breasts [7, 8] . The absence of contra-indications to Q-SPECT/CT also makes it a preferred option for patients with kidney impairment [6] . A significant number of venous and pulmonary thromboembolic complications have been observed in COVID-19 patients, especially critically ill patients [36, 37] . Those patients were excluded in our study because of the high likelihood of lung parenchymal abnormality that may lead to difficulties of interpretation and potential false positive results [38] . Moreover, the pathogenesis and management of thromboembolic events in COVID-19 were not fully understood during the time of data collection and may have potentially confounded the subsequent outcome analysis. Based on our findings, Q-SPECT/CT demonstrates 100% sensitivity and 100% NPV. Such high sensitivity is inconsistent with previous numerous studies by Mazurek Fig. 3 Two false positive cases. The first case showed large and moderate segmental perfusion defects which corresponded to hyperexpanded oligaemic lung parenchyma on Q-SPECT/CT (arrow, a-d). The second case was diagnosed as cardiac failure. Q-SPECT/CT showed upper lobe diversion of 99mTc-MAA resulting lower lobar perfusion defects. Cardiomegaly was also seen (bold arrow, e-g) et al., Sevda et al. and Wang et al., where the sensitivity ranges between 93 and 100% [12, 13, 16] . Furthermore, high NPV implies that a normal Q-SPECT/CT is able to exclude PE or CTEPH with high degree of confidence. In our study, no worsening of clinical outcome was observed when Q-SPECT/CT was normal. Three patients were falsely positive in our study, of which one patient showed segmental hyperexpanded oligaemic lung parenchyma with perfusion defects on Q-SPECT/CT. Although perfusion defect in emphysema is uncommon, such findings have been reported and are postulated to be related to vascular changes [39, 40] . Cardiac failure can result in upper lobe diversion of 99mTc-MAA which may lead to lower lobar perfusion defects mimicking embolic defects. Therefore, we suggest that familiarity with features of emphysema on CT and clinical correlation may minimise such potential pitfalls [41, 42] . Our observed false positive rate was higher as compare to previous studies conducted by Le [16, 19, 20] . The possible reason of higher false positive rate observed in our study is partly due to the use of different reference standards. Both Le Roux's and Palmowski's studies used VQ-SPECT and Wang's study used pulmonary angiography as reference standards, whereas clinical endpoint was used in our study as reference standard. The limitation of this study is small sample size, which is partly due to low number of referrals during COVID-19 pandemics, exclusion of CTPA confirmed case and exclusion of patients with obvious lung parenchymal disease on initial CXR and HRCT. Another limitation is absence of control group for comparison. Another potential pitfall is the classification of true negative when there is absence of clinical deterioration over 2-month observation period. Although a 2-month cutoff period was used for the purpose of outcome analysis, it is possible that asymptomatic microthrombi went undetected and were therefore missed during the observation period. In conclusion, our outcome analysis suggests that Q-SPECT/CT has high sensitivity and NPV in evaluating pulmonary thromboembolic disease. Normal Q-SPECT/ CT excludes pulmonary thromboembolic disease with high degree of certainty. We suggest no further testing when the Q-SPECT/CT is normal. However, false positive has been observed and careful clinical and CT correlation may be warranted in such and additional testing may be necessary as recommended by Zuckier et al. [10] . In the current COVID-19 pandemics, Q-SPECT/CT can be an alternative modality to detect pulmonary thromboembolic disease in view of the exposure risks associated with ventilation study. Pulmonary embolism, part I: epidemiology, risk factors and risk stratification, pathophysiology, clinical presentation, diagnosis and nonthrombotic pulmonary embolism Acute pulmonary embolism: clinical outcomes in the International Cooperative Pulmonary Embolism Registry (ICOPER) Chronic thromboembolic pulmonary hypertension:a distinct disease entity Chronic thromboembolic pulmonary hypertension Imaging of acute pulmonary embolism: an update ESC Guidelines for the diagnosis and management of acute pulmonary embolism developed in collaboration with the Ventilation-perfusion SPECT versus CTPA in young adult females with suspected pulmonary embolism Detection of pulmonary embolism during pregnancy: comparing radiation doses of CTPA and pulomonary scintigraphy Perfusion scintigraphy in diagnosis and management of thromboembolic pulmonary hypertension Diagnostic evaluation of pulmonary embolism during the COVID-19 pandemic Perfusion SPECT/CT to diagnose pulmonary embolism during COVID-19 pandemic The utility of hybrid SPECT/CT lung perfusion scintigraphy in pulmonary embolism diagnosis Diagnostic value of perfusion lung scintigraphy in SPECT/CT and computed tomography pulmonary angiography for detection of pulmonary embolism Pilot study comparing SPECT perfusion scintigraphy with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: headto-head comparison with multidetector CT angiography A prospective, comparative study of ventilation-perfusion planar imaging and ventilation-perfusion SPECT for chronic thromboembolic pulmonary hypertension Diagnosis of pulmonary embolism: a comparison between ventilation/perfusion SPECT/CT and perfusion-only SPECT/CT Lung scintigraphy for pulmonary embolism diagnosis during the COVID-19 pandemic: does the benefit-risk ratio really justify omitting the ventilation study? Additional value of combining low-dose computed tomography to V/Q SPECT on a hybrid SPECT-CT camera for pulmonary embolism diagnosis Diagnosis of pulmonary embolism: conventional ventilation/perfusion SPECT is superior to the combination of perfusion SPECT and nonenhanced CT Clinical criteria to prevent unnecessary diagnostic testing in emergency department patients with suspected pulmonary embolism Prediction of pulmonary embolism in the emergency department: the revised Geneva score EANM guideline for ventilation/perfusion singlephoton emission computed tomography (SPECT) for diagnosis of pulmonary embolism and beyond Noncontrast perfusion single-photon emission CT/CT scanning: a new test for the expedited, high-accuracy diagnosis of acute pulmonary embolism Value of perfusion lung scan in the diagnosis of pulmonary embolism: results of the Prospective Investigative Study of Acute Pulmonary Embolism Diagnosis (PISA-PED) Chronic thromboembolic pulmonary hypertension: role of medical therapy Ventilation/perfusion SPECT for diagnostics of pulmonary embolism in clinical practice Three-year clinical experience with VQ SPECT for diagnosing pulmonary embolism: diagnostic performance Diagnostic usefulness of lung SPET in pulmonary thromboembolism: an outcome study Diagnostic accuracy of single-photon emission tomography ventilation/perfusion lung scan in the diagnosis of pulmonary embolism The accuracy of V/Q SPECT in the diagnosis of pulmonary embolism: a metaanalysis Systematic review and meta-analysis of test accuracy for the diagnosis of suspected pulmonary embolism The economic value of hybrid single-photon emission computed tomography with computed tomography imaging in pulmonary embolism diagnosis Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension Appropriate use criteria for ventilation-perfusion imaging in pulmonary embolism: summary and excerpts Thromboembolic disease in COVID-19 patients: a brief narrative review Pulmonary embolism and deep vein thrombosis in COVID-19: a systematic review and meta-analysis Ventilation/perfusion SPECT/CT findings in different lung lesions associated with COVID-19: a case series The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used Identifying the heterogeneity of COPD by V/P SPECT: a new tool for improving the diagnosis of parenchymal defects and grading the severity of small airways disease CT-definable subtypes of chronic obstructive pulmonary disease: a statement of the Fleischner Society Artifacts and anatomical variants affecting ventilation and perfusion lung imaging The authors would like to thank Dr. Jay Suriar