key: cord-0069964-sxpk41az authors: Torrini, Flavia; Gendreau, Ségolène; Morel, Johanna; Carteaux, Guillaume; Thille, Arnaud W.; Antonelli, Massimo; Mekontso Dessap, Armand title: Prediction of extubation outcome in critically ill patients: a systematic review and meta-analysis date: 2021-11-15 journal: Crit Care DOI: 10.1186/s13054-021-03802-3 sha: 72d0e44058b5ec36698280e2d0a3151794e07f2e doc_id: 69964 cord_uid: sxpk41az BACKGROUND: Extubation failure is an important issue in ventilated patients and its risk factors remain a matter of research. We conducted a systematic review and meta-analysis to explore factors associated with extubation failure in ventilated patients who passed a spontaneous breathing trial and underwent planned extubation. This systematic review was registered in PROPERO with the Registration ID CRD42019137003. METHODS: We searched the PubMed, Web of Science and Cochrane Controlled Register of Trials for studies published from January 1998 to December 2018. We included observational studies involving risk factors associated with extubation failure in adult intensive care unit patients who underwent invasive mechanical ventilation. Two authors independently extracted data and assessed the validity of included studies. RESULTS: Sixty-seven studies (involving 26,847 participants) met the inclusion criteria and were included in our meta-analysis. We analyzed 49 variables and, among them, we identified 26 factors significantly associated with extubation failure. Risk factors were distributed into three domains (comorbidities, acute disease severity and characteristics at time of extubation) involving mainly three functions (circulatory, respiratory and neurological). Among these, the physiological respiratory characteristics at time of extubation were the most represented. The individual topic of secretion management was the one with the largest number of variables. By Bayesian multivariable meta-analysis, twelve factors were significantly associated with extubation failure: age, history of cardiac disease, history of respiratory disease, Simplified Acute Physiologic Score II score, pneumonia, duration of mechanical ventilation, heart rate, Rapid Shallow Breathing Index, negative inspiratory force, lower PaO(2)/FiO(2) ratio, lower hemoglobin level and lower Glasgow Coma Scale before extubation, with the latest factor having the strongest association with extubation outcome. CONCLUSIONS: Numerous factors are associated with extubation failure in critically ill patients who have passed a spontaneous breathing trial. Robust multiparametric clinical scores and/or artificial intelligence algorithms should be tested based on the selected independent variables in order to improve the prediction of extubation outcome in the clinical scenario. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-021-03802-3. Background As mechanical ventilation is associated with complications (e.g., ventilator-associated pneumonia) [1] , the optimal time to wean patients from mechanical ventilation is a critical goal to achieve in intensive care unit (ICU) [2] . The decision to extubate is therefore usually taken as soon as a patient meet predefined weaning criteria and successfully pass a spontaneous breathing trial (SBT) [3] . Nevertheless, in 10-20% of patients who pass a spontaneous breathing trial and undergo planned extubation, extubation failure still occurs. Extubation failure is usually defined as the need for reintubation within hours or days after a planned extubation. The time considered varies from 24 h [4, 5] until any time during the hospital stay [6, 7] . Extubation failure is associated with an overall increase in the duration of mechanical ventilation, a greater need for tracheostomy, higher medical costs and a 25-50% increased mortality rate [8] [9] [10] [11] [12] . There is some evidence that extubation failure is not just a marker of a more severe illness, but independently affects patients survival regardless of underlying illness severity [9, 13] . Unfortunately, the pathophysiology of extubation failure is not yet fully understood and a simple tool for predicting extubation failure is not available. Some studies suggested that the use of standardized weaning protocols reduced the total time of mechanical ventilation [14, 15] but the parameters that should be included in weaning protocols still remain controversial. Considering the complications associated with both a too early and delayed liberation from mechanical ventilation, the identification of robust risk factors for extubation failure would be extremely helpful in order to optimize the weaning process. We therefore decided to conduct a systematic review of the literature and a meta-analysis to search risk factors associated with extubation failure, in adult critically ill patients who passed a SBT and underwent a planned extubation. We performed this study in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement [16] . We searched PubMed, Web of Science and Cochrane controlled register of trials (CENTRAL) to identify articles on risk factors for extubation failure from January 1998 to December 2018. We used the following search algorithm: (extubation) AND (success OR failure OR factor OR predictor OR prediction OR risk OR score OR outcome OR mortality OR reintubation OR intensive care unit). We included all studies that evaluated any risk factors for extubation failure in adult (at least 18 years old) ICU patients under invasive mechanical ventilation. We excluded studies in children and animals and studies not written in English. References of all selected articles were scanned for additional relevant manuscripts. This study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) database (Registration Number CRD42019137003). Ethical approval was not required. After the removal of the duplicates, two authors (FT, JM) independently screened titles and abstracts to obtain relevant articles for full text review. We obtained the full text of all potentially relevant studies and the authors independently decided for final inclusion in the review. We also reviewed the references of relevant articles to avoid missing any studies. Any disagreement was resolved by consensus or discussion with a third reviewer (AMD). The review authors independently extracted data. The following data were recorded from each selected study: year of publication, study design, baseline characteristics of the population (age, comorbidities), severity scores on ICU admission and stay [Severity Acute Physiologic Score (SAPS), Acute Physiology and Chronic Health Evaluation (APACHE)], medications, characteristics of the SBT, definition of extubation failure, risk factors associated with extubation failure (respiratory, cardiovascular, neurologic, laboratory parameters) and primary outcome (extubation failure). We further excluded risk factors with excessive missing data (reported in less than 10% of studies; see Additional file 1: Table S1 in the additional material). Study quality was assessed in terms of risk of bias using the QUIPS tool for prognostic studies (Cochrane), rating the potential risk of bias as high, moderate or low for each of six domains, namely study participation, study attrition, prognostic factor measurement, outcome measurement, study confounding, statistical analysis and reporting. Two authors (FT, JM) independently assessed the risk of bias, implying a third author in case of disagreement (AMD). We conducted a meta-analysis of observational prospective and retrospective studies. Data were summarized using medians and interquartile ranges (IQRs) or mean ± standard deviation (SD) were appropriate [17] . For binary variables, the odds ratio (OR) with 95% confidence interval (CI) was calculated for extubation failure. For continuous variables, we calculated the mean difference with 95% CI between extubation success and extubation failure groups. A natural log transformation of OR (lnOR) was derived from crude OR (for binary variables) [18, 19] and from standardized mean differences (for continuous variables) [19] in a symmetric scale, from minus infinity, to infinity, with zero defining no effect [18] , to allow comparison between categorical and numeric variables. We adopted the inverse variance method for developing weights for individual study effects. We quantified heterogeneity using I 2 and Q statistics, with values greater than 50% regarded as being indicative of moderate-to-high heterogeneity [20] . We used a random effect model to assess the population average mean difference and 95% CI or OR and 95% CI for all the risk factors for extubation failure. In order to measure the dispersion of the pooled effect across study settings, we generated predictions intervals [21] . We performed prespecified subgroup analyses according to the type of ICU patients, e.g., medical, surgical, mixed, neurological or other type of ICU. A heatmap was created to present lnOR (scaled to adjust for extreme values) for each variable according to ICU type. We conducted a sensitivity analysis including only studies referring to the most used definition of extubation failure (death or reintubation within 48 h from extubation), to explore if it changed the significance of the results. Another sensitivity analysis focused on studies referring to death or reintubation (whatever the delay). A multivariable meta-analysis of multiple factors was secondarily performed with variables significantly associated with extubation outcome, using effect sizes as lnOR [22] and the altmeta package for R [23, 24] . Among related significant univariate factors, only the most statistically robust (as per the lnOR), yet clinically relevant were entered into the models in order to minimize the effect of collinearity. Individual study effects and pooled effects were visualized through forest plots. Publication biases were assessed graphically through funnel plot asymmetry [25] . Data were pooled and analyzed using Review Manager (Cochrane TC. Review Manager 5.3. Cph Nord Cochrane Cent, 2008) with a two-sided significance level of 5%, and R 3.1.2 (The R Foundation for Statistical Computing, Vienna, Austria). We identified a total of 12,921 references from our searches (Fig. 1 ). After removing 4833 duplicates, we screened the titles and abstracts of 8088 articles, of which 7927 were excluded. The full texts of 161 studies were reviewed and 94 were excluded. Thus, we included 67 studies in the narrative review, and 66 studies were included in the quantitative synthesis. Of the 67 studies included in the review, 50 were prospective observational studies [4-6, 9, 12, 13, 26-69] and 17 were retrospective studies [7, [70] [71] [72] [73] [74] [75] [76] [77] [78] [79] [80] [81] [82] [83] [84] [85] . Fifty-seven studies were monocentric and ten were multicentric. Studies took place in medical (n = 19), surgical (n = 9), mixed (n = 28) and neurological (n = 11) ICUs. We included 67 studies involving 26,847 participants in the meta-analysis. The type of SBT and the definition of extubation failure varied among the included studies (Table 1) . SBT types included: multiple choice for SBT (n = 15, with 4 studies allowing CPAP and 14 studies allowing T-tube), low pressure support with low positive end expiratory pressure (n = 30), flow-by (n = 1), standard pressure support ventilation (n = 1), proportional assist ventilation (n = 1) and automatic tube compensation with low PEEP (n = 1). Extubation failure was defined either as death or reintubation within hours to days after extubation (24 h, 48 h, 72 h or 7 days in 4, 30, 14 and 5 studies, respectively), or as the reinstitution of any mechanical ventilation after extubation, either invasive or noninvasive with a curative indication (10 studies). Among the 49 variables analyzed, we found 26 variables significantly associated with extubation outcome, distributed into three domains [comorbidities (n = 5), acute disease severity (n = 6) and characteristics at time of extubation (n = 15)] ( Table 2 , Fig. 2 ) involving mainly three functions [respiratory (n = 16), circulatory (n = 3) and neurological (n = 1)]; see Additional file 1: Fig. S1 in the additional material). We found a higher risk of extubation failure in older patients. Chronic obstructive respiratory disease, history of chronic cardiac or respiratory disease were associated with a higher risk of extubation failure as well. In contrast, a higher body mass index was associated with successful extubation. Patients who failed extubation also differed from patients who succeeded in terms of acute disease severity, with higher values of SAPS II and APACHE II score in the former group. Acute heart failure, COPD exacerbation and pneumonia were the reasons for intubation significantly associated with a higher risk of extubation failure. Duration of mechanical ventilation before extubation was longer in patients with extubation failure. These variables involved the following physiological systems: (1) inspiratory force), ventilation pattern [respiratory rate and tidal volume before extubation, rapid shallow breathing index (RSBI) after one minute from the SBT start, RSBI before extubation] and oxygenation (SaO 2 , PaO 2 and PaO 2 /FiO 2 before extubation, hemoglobin on the day of extubation); (2) cardiovascular (heart rate before extubation); and (3) neurological (Glasgow Coma Scale before extubation). The individual topic of secretion management was the one with the largest number variables (five). Subgroup analyses according to the type of ICU are presented in Additional file 1: Fig. S2 and Table S2 in the additional material. Among the 49 variables analyzed, 30 were significantly associated with extubation outcome in at least one ICU type. Eight factors were significant in the majority of ICU types (at least three among the five types), including age, SAPS II score, duration of mechanical ventilation before extubation, heart rate, respiratory rate, RSBI, PaO 2 before extubation and cough peak flow. Duration of mechanical ventilation had the broadest association across ICU types (4/5 types), while cough peak flow had the strongest association across ICU types (Additional file 1: Fig. S2 ). Due to the heterogeneity among studies in terms of definition of extubation failure, we performed an exploratory sensitivity analysis restricted to studies where extubation failure was defined as death or reintubation, whatever the delay (57 out of 67 included in the meta-analysis): the vast majority of variables identified by crude analysis (23) remained significant, while only three were not (see Fig. 2 , and Additional file 1: Table S3 in the additional material). Another sensitivity analysis was restricted to studies where extubation failure was defined as death or reintubation within 48 h (30 articles out of 67 included in the meta-analysis): 15 variables remained significant while eleven were not, including factors related to cough and tracheal secretions (see Fig. 2 , and Additional file 1: Table S4 in the additional material). The 26 variables significantly associated with extubation outcome were assessed using a multivariable analysis for multiple factors (Additional file 1: Fig. S3 in the additional material). Twelve variables (age, history of cardiac disease, history of respiratory disease, SAPS II score, duration of mechanical ventilation, pneumonia, heart rate, RSBI, negative inspiratory force, lower PaO 2 / FiO 2 , lower Glasgow Coma Scale and lower hemoglobin level before extubation) were retained in the final model (Fig. 3) . Glasgow Coma Scale (GCS) before extubation had the strongest independent association with extubation outcome. Included studies differed in their methodological quality (Fig. 4 , and Additional file 1: Fig. S4 in the additional material). High risk of bias was related to the study participation in eight studies [47, 57, [78] [79] [80] [81] [82] 85] , to study attrition in one study [33] , to prognostic factor measurement in one study [7] , to the outcome measurement in two studies [29, 77] and to study confounding in five studies [27, 65, 78, 81, 85] . The remaining studies had low or unclear risk of bias for each of the six domains. To the best of our knowledge, we herein report the first meta-analysis on factors associated with extubation failure. By multivariable analysis, twelve factors were significantly associated with extubation failure: age, history of cardiac disease, history of respiratory disease, SAPS II score, duration of mechanical ventilation, pneumonia, heart rate, RSBI, negative inspiratory force, lower PaO 2 / FiO 2 , lower hemoglobin level before extubation and lower Glasgow Coma Scale before extubation, with the latest factor having the strongest independent association with extubation outcome. An important information that comes out from our systematic review is that there is lack of standardization about the definition of extubation failure. It was defined as death or reintubation within a time interval that varies from 24 h to 7 days and in some studies, it also comprised the need for curative noninvasive ventilation after extubation. This leads to a risk of bias in evaluating N number of participants, n number of studies, ext extubation, SBT spontaneous breathing trial, SAPS severity acute physiologic score, APACHE acute physiology and chronic health evaluation, COPD chronic obstructive pulmonary disease, ARDS acute respiratory distress syndrome, PaCO2 partial pressure of carbon dioxide in the arterial blood, PaO2 partial pressure of oxygen in the arterial blood, SaO2 oxygen saturation in the arterial blood, FiO2 fraction of inspired oxygen, RSBI Rapid Shallow Breathing Index, PEEP positive end expiratory pressure, *statistically significant by meta-analysis use of death or reintubation within a seven-day delay to define extubation failure in future studies [86] . As highlighted in the present work, many factors may contribute to extubation failure in a given critically ill patient, suggesting an individual pathophysiological approach. The topic of secretion management was the one with the largest number of variables (five) significantly associated with extubation failure, pointing out that it should be carefully evaluated before extubation. The assessment of the "upper airway patency", in terms of amount of secretions and the ability to clear them through an effective cough, has been increasingly used in the literature, even though these parameters are difficult to measure in an objective and standardized way. Cough peak flow is a parameter that has been proposed in the last few years to overcome this problem, but our multivariable analysis suggests negative inspiratory pressure as a relevant indicator. Although the majority of statistically significant variables from our meta-analysis were related to the respiratory function (16 variables), the circulatory (three variables) and neurological (one variable) functions were also involved, with Glasgow Coma Scale having the strongest association with extubation outcome by multivariable analysis. These results are consistent with the plurality of often-intertwined mechanisms of extubation failure. Thus, restricting the clinical reasoning to the spectrum of a few variables related to the respiratory function may weaken the decisional process of liberation from mechanical ventilation. Robust multiparametric clinical scores and/or artificial intelligence algorithms should be tested based on the selected variables in order to improve the prediction of extubation outcome in the clinical scenario. Strengths of our study include the wide period of assessment and selection process. One limitation is the lack of standardization in the definition of extubation failure. However, we performed a sensitivity analysis using the most accepted definition. Another limitation is that, due to the lack of data, we could not analyze the postextubation stridor, which is considered a rare but important risk factor for extubation failure. Finally, we may have missed other potentially important factors since we chose to analyze only parameters evaluated in at least 10% of included studies. We performed a systematic review and meta-analysis of a wide population of critically ill patients, finding 26 and 12 risk factors for extubation failure in patients who have successfully passed a spontaneous breathing trial by univariate and multivariable analysis, respectively. These factors were related to age, comorbidities, acute disease severity and physiological characteristics at the time of extubation. To further explore these factors and their combination, a unique definition of extubation failure is needed. An automated algorithm incorporating these factors would probably be very useful to inform the decisional process of extubation. The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s13054-021-03802-3. Additional file 1: Table S1 . Variables excluded because of missing data. Figure S1 . Forest plots for variables statistically significantly associated with extubation failure. Table S2 . Subgroup analyses by intensive care unit type. Figure S2 . Heatmap of natural log transformation of odd ratios (LnOR) for extubation failure, according to ICU type. Table S3 . Sensitivity analysis focusing on studies defining extubation failure as death or reintubation, whatever the delay. Table S4 . Sensitivity analysis focusing on studies defining extubation failure at 48 h. Figure S3 . Individual risk of bias in the included studies. Figure S4 . Forest plot for the 26 variables significantly associated with extubation failure, assessed by multivariate meta-analysis for multiple factors. Outcome of patients undergoing prolonged mechanical ventilation after critical illness Weaning from mechanical ventilation Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously Evolution of pattern of breathing during a spontaneous breathing trial predicts successful extubation Role of hematocrit concentration on successful extubation in critically ill patients in the intensive care units Involuntary cough strength and extubation outcomes for patients in an ICU Predictors of reintubation in critically ill patients The decision to extubate in the intensive care unit Outcomes of extubation failure in medical intensive care unit patients Effect of spontaneous breathing trial duration on outcome of attempts to 1999discon-tinue mechanical ventilation. Spanish Lung Failure Collaborative Group Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation Risk factors for extubation failure in patients following a successful spontaneous breathing trial Outcome of reintubated patients after scheduled extubation A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation Clinical consequences of the implementation of a weaning protocol Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range Cochrane handbook for systematic reviews of interventions Chapter 6: Choosing effect measures and computing estimates of effect. Cochrane handbook systematic review interventions version 62 update Quantifying heterogeneity in a meta-analysis Interpretation of random effects metaanalyses A simple method for converting an odds ratio to effect size for use in meta-analysis Bayesian multivariate meta-analysis of multiple factors An alternative model for bivariate random-effects meta-analysis when the within-study correlations are unknown Bias in meta-analysis detected by a simple, graphical test A decisiontree model for predicting extubation outcome in elderly patients after a successful spontaneous breathing trial Lower interbreath interval complexity is associated with extubation failure in mechanically ventilated patients during spontaneous breathing trials Erratum to: Do heart and respiratory rate variability improve prediction of extubation outcomes in critically ill patients? Crit Care Risk factors associated with early reintubation in trauma patients: a prospective observational study Brun-Buisson C. Risk factors for and prediction by caregivers of extubation failure in ICU patients: a prospective study Semiquantitative cough strength score for predicting reintubation after planned extubation Swallowing disorders as a predictor of unsuccessful extubation: a clinical evaluation The modified integrative weaning index as a predictor of extubation failure Variation of risk factors for cause-specific reintubation: a preliminary study Associação entre o índice de respiração rápida e superficial e o sucesso da extubação em pacientes com traumatismo cranioencefálico Central venous saturation is a predictor of reintubation in difficult-to-wean patients Changes in B-type natriuretic peptide improve weaning outcome predicted by spontaneous breathing trial Cough strength, secretions and extubation outcome in burn patients who have passed a spontaneous breathing trial Development of a risk score to predict extubation failure in patients with traumatic brain injury Easily identified at-risk patients for extubation failure may benefit from noninvasive ventilation: a prospective before-after study Extubation failure in the elderly Extubation failure: diagnostic value of occlusion pressure (P0.1) and P0.1-derived parameters Risk factors and outcomes for airway failure versus non-airway failure in the intensive care unit: a multicenter observational study of 1514 extubation procedures Extubation success prediction in a multicentric cohort of patients with severe brain injury Incidence, indication and complications of postoperative reintubation after elective intracranial surgery Increase in intra-abdominal pressure during airway suctioning-induced cough after a successful spontaneous breathing trial is associated with extubation outcome. Ann Intensive Care Minute ventilation recovery time measured using a new, simplified methodology predicts extubation outcome Minute ventilation recovery time: a predictor of extubation outcome Modified rapid shallow breathing index adjusted with anthropometric parameters increases predictive power for extubation failure compared with the unmodified index in postcardiac surgery patients Neurologic status, cough, secretions and extubation outcomes Noninvasive work of breathing improves prediction of post-extubation outcome Postintubation laryngeal injuries and extubation failure: a fiberoptic endoscopic study Predicting extubation failure after successful completion of a spontaneous breathing trial Predicting extubation outcome by cough peak flow measured using a built-in ventilator flow meter Prospective observational study of predictors of re-intubation following extubation in the surgical ICU Reflex cough PEF as a predictor of successful extubation in neurological patients Semi-quantitative cough strength score as a predictor for extubation outcome in traumatic brain injury: a prospective observational study Simple motor tasks independently predict extubation failure in critically ill neurological patients The early phase of the minute ventilation recovery curve predicts extubation failure better than the minute ventilation recovery time Tracheostomy, extubation, reintubation: airway management decisions in intubated stroke patients Use of cough peak flow measured by a ventilator to predict re-intubation when a spirometer is unavailable Weaning predictors do not predict extubation failure in simple-to-wean patients Airway management strategies for brain-injured patients meeting standard criteria to consider extubation: a prospective cohort study Extubation failure in brain-injured patients Diaphragm ultrasound as a new method to predict extubation outcome in mechanically ventilated patients Extubation outcome after a successful spontaneous breathing trial: a multicenter validation of a 3-factor prediction model Improvement in the prediction of ventilator weaning outcomes by an artificial neural network in a medical ICU Serial measurements of f/VT can predict extubation failure in patients with f/VT ≤ 105? Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients Occurrence and complications of tracheal reintubation in critically ill adults An artificial neural network model for predicting successful extubation in intensive care units Comparison of clinical utility between diaphragm excursion and thickening change using ultrasonography to predict extubation success Establishing failure predictors for the planned extubation of overweight and obese patients Establishing predictors for successfully planned endotracheal extubation Factors associated with reintubation in patients with chronic obstructive pulmonary disease Low mechanical ventilation times and reintubation rates associated with a specific weaning protocol in an intensive care unit setting: a retrospective study Prediction of extubation failure in medical intensive care unit patients Predictors of extubation success in patients with posterior fossa strokes Predictors of re-intubation in trauma intensive care unit: Qatar experience Reintubation after planned extubation in surgical ICU patients: a case-control study The impact of extubation failure in patients with good-grade subarachnoid hemorrhage convenient online submission • thorough peer review by experienced researchers in your field • rapid publication on acceptance • support for research data, including large and complex data types • gold Open Access which fosters wider collaboration and increased citations maximum visibility for your research: over 100M website views per year submit your research ? Value of the PaO 2 :FiO 2 ratio and Rapid Shallow Breathing Index in predicting successful extubation in hypoxemic respiratory failure Lung-thorax compliance measured during a spontaneous breathing trial is a good index of extubation failure in the surgical intensive care unit: a retrospective cohort study Predictors of extubation failure in patients with chronic obstructive pulmonary disease Sensitivity and specificity of the Yang Tobin Index to predict extubation success in critical patients Epidemiology of weaning outcome according to a new definition. The WIND study Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Not applicable. Authors' contributions AMD, FT and JM designed the meta-analysis. FT and JM searched for the articles, screened titles and abstracts and extracted data. AMD, FT and SG performed statistical analysis and interpretation of data. AWT, GC and MA contributed to the conception of the study. FT and AMD drafted the manuscript, and FT, SG, JM, GC, AWT, MA and AMD revised it for important intellectual content; all authors read and approved the final manuscript. None. Data sharing is not applicable to this article as no datasets were generated or analyzed during the current study.