key: cord-0066134-cjvz0tzh authors: Yehia, Nahed; Eldemery, Fatma; Arafa, Abdel-Satar; Abd El Wahed, Ahmed; El Sanousi, Ahmed; Weidmann, Manfred; Shalaby, Mohamed title: Reverse Transcription Recombinase Polymerase Amplification Assay for Rapid Detection of Avian Influenza Virus H9N2 HA Gene date: 2021-07-16 journal: Vet Sci DOI: 10.3390/vetsci8070134 sha: 96406ac6d2aca0f5012f0f4435bf8fdce8d88710 doc_id: 66134 cord_uid: cjvz0tzh The H9N2 subtype of avian influenza A virus (aIAV) is circulating among birds worldwide, leading to severe economic losses. H9N2 cocirculation with other highly pathogenic aIAVs has the potential to contribute to the rise of new strains with pandemic potential. Therefore, rapid detection of H9 aIAVs infection is crucial to control virus spread. A qualitative reverse transcription recombinase polymerase amplification (RT-RPA) assay for the detection of aIAV subtype H9N2 was developed. All results were compared to the gold standard (real-time reverse transcription polymerase chain reaction (RT-PCR)). The RT-RPA assay was designed to detect the hemagglutinin (HA) gene of H9N2 by testing three pairs of primers and a probe. A serial concentration between 10(6) and 10(0) EID(50) (50% embryo infective dose)/mL was applied to calculate the analytical sensitivity. The H9 RT-RPA assay was highly sensitive as the lowest concentration point of a standard range at one EID(50)/mL was detected after 5 to 8 min. The H9N2 RT-RPA assay was highly specific as nucleic acid extracted from H9 negative samples and from other avian pathogens were not cross detected. The diagnostic sensitivity when testing clinical samples was 100% for RT-RPA and RT-PCR. In conclusion, H9N2 RT-RPA is a rapid sensitive and specific assay that easily operable in a portable device for field diagnosis of aIAV H9N2. Influenza A viruses (IAVs) are enveloped, single-stranded, negative-sense RNA viruses [1] . The IAV genome is segmented into eight RNA segments: RNA polymerase basic subunit (PB)2, PB1, RNA polymerase acidic subunit (PA), hemagglutinin (HA), nucleoprotein (NP), neuraminidase (NA), matrix (M) (encodes two matrix proteins (M1 and M2)), and non-structural (NS) segment [2] . Influenza A viruses are divided into subtypes based on HA and NA. So far, 18 HA subtypes and 11 NA subtypes have been identified thus, many different combinations of HA and NA exist [3] . H9N2 aIAVs continue to evolve and circulate in different bird species and poultry, and pose a public health concern [4] . Vet The crucial characteristics of aIAVs in general and H9N2 virus in particular are the wide host range, extensive gene reassortment, and adaptation to wild birds, poultry and mammals [5, 6] . Co-circulation of H9N2 with other highly pathogenic aIAVs such as H5N1 and H5N8 has been reported in Egypt [7] [8] [9] . For instance, recent analyses of human infections with aIAVs showed that H9N2 is the gene donor for H7N9 and H10N8 viruses [10] , and that H9N2 has a great potential to emerge as a new virus infecting humans [4, 11] . Additionally, the Egyptian H9N2 viruses were found to bind more to human-like receptors (α2,6-SL, Neu5Acα2-6Galβ1-4Glc, α2,6-SLN, Neu5Acα2-6Galβ1-4GlcNAc) than to avian-like receptors (α2,3-SL, Neu5Acα2-3Galβ1-4Glc) [12] . H9N2 has emerged and become endemic in Egypt since 2010, with a serious economic impact on the poultry industry [9] . When H9N2 infection occurs combined with secondary infections, high morbidity and mortality and great economic losses are recorded [13, 14] . H9N2 subtypes circulating from 2016-2018 presented a mix of more recent segments emerging since 2014 and older M1, M2, and NS gene sequences known from H9N2 virus isolates of 2010, indicating ongoing drift and reassortment amongst H9N2 viruses [7] . However, the Egyptian H9N2 viruses are low pathogenic (LPAI), asymptomatically infected poultry shed and spread the virus via the oral and cloacal route sustaining circulation. This silent spread of the virus in the field might generate new sub-and genotypes of aIAVs. Recently more antigenic drifts were recorded for Egyptian H9N2 isolates compared to isolates from other countries [7] . Moreover, the NA enzymatic activities of Egyptian N9N2 strains were tremendous [15] . Thus, Egypt is potentially developing into a hotspot for new influenza pandemics [16] . Rapid point-of-need diagnostic tests are necessary in order to stop the viral spread and decrease the burden on the economy [17] . Routine detection of aIAVs in clinical samples is performed by viral isolation, which is time-consuming. DNA amplificationbased molecular techniques such as polymerase chain reaction (RT-PCR) are more sensitive and rapid but need sophisticated equipment and protocols [18] . In addition, the RT-PCR assay has a long runtime of more than one hour [19, 20] . The recombinase polymerase amplification (RPA) technique has been successfully developed as a rapid diagnostic method of aIAVs viruses such as H7N9 and H5N1 [19, [21] [22] [23] [24] . Unlike PCR, RPA works at a constant low temperature and completes amplification within minutes [25] . The reaction is accomplished by a particular enzyme mixture instead of seven proteins and repetitive thermal cycling. The recombinase, strand-displacing DNA polymerase and single-stranded DNA-binding protein represent the core of the RPA reaction at temperatures between 37 • C and 42 • C. The RPA product can be visualized using electrophoresis, lateral flow dipsticks (LFD) [22, 24] , or by probe-based real-time amplification generating results in less than 20 min [19, 26] . In this study, we aimed to develop a probe-based RT-RPA and evaluated its performance for field detection of the HA gene of avian influenza H9N2. All samples used in the study were part of the routine national surveillance program of IAVs in Egypt, and, therefore, no ethical approval was required. No sample was collected, or animals were slaughtered specifically for this study because all samples were archived RNA samples from the national depository at the Egyptian National Reference Laboratory for IAVs (Animal Health Research Institute, Agriculture Research Centre, AHRI, Giza, Egypt). The standard RNA was extracted from Egyptian H9N2 reference strain (A/chicken/ Egypt/1373Vd/2013(H9N2)), GenBank accession number KJ781216 that was titrated using specific pathogen free (SPF) embryonated chicken eggs (ECE). Virus titer shown as EID 50 (50% embryo infective dose)/mL was calculated using the Reed and Muench method, as previously described [27] . The QIAamp Viral RNA Mini Kit was applied according to the manufacturer's directions (Qiagen, Hilden, Germany) to extract the viral RNA from clinical swabs. Samples were either allantoic fluid or phosphate-buffered saline (PBS) suspensions containing tracheal swabs of a total volume of 200 µL. RNA was eluted in a final volume of 60 µL and stored at −80 • C. Three forward, three reverse primers, and one exo-probe were used to amplifỹ 240-280 pb of the HA gene to select the best combination providing the highest RT-RPA assay sensitivity (Table 1) The H9 RT-RPA was performed in a 50 µL reaction volume using Twist Amp exo RT kits (Twist Dx, Cambridge, UK) according to the manufacturer's directions, as previously described [19] . In brief, the 50 µL reaction was performed according to the following formula: 1 µL of each RPA primers (10 pmol Conc.), 0.6 µL RPA exo-probe (10 pmol Conc.), 4 µL of magnesium acetate (14 mM Conc.), 29.5 µL of 4 × rehydration buffer (Twist Amp, Cambridge, UK), and 1 µL RNA template then PCR grade water (Qiagen, Hilden, Germany) was added to adjust the reaction volume up to 50 µL. This mix was added to the RPA strips containing a dried enzyme pellet. Heating and fluorescence measurements were conducted in an ESE Quant tube scanner (Qiagen, Lake Constance, Germany) at 42 • C for 20 min. The threshold time (TT) was determined by combining threshold and signals loop analysis confirmed by 1st derivative analysis in the tube scanner software. The limit of detection of H9 RT-RPA assay was determined using a serial dilution range of titrated aIAVs EID 50 from 10 5 EID 50 /mL to 10 EID 50 /mL in eight replicates. The RNA concentration was calculated using the previously developed real-time RT-PCR [28] and Quantitect probe RT-PCR kit (Qiagen, Inc., Valencia, CA, USA). PRISM (Graphpad Software Inc. version 6.0 Mac, SanDiego, CA, USA) was applied to plot the RT-RPA threshold time against RNA molecules detected after performing semi-log regression. Nucleic acid from other influenza viruses, including H5N2 and H7N1, and three viruses producing respiratory signs including infectious laryngotracheitis virus (ILTV), infectious bronchitis virus (IBV) and Newcastle disease virus (NDV) (supplemented from GD Lab, Holland, a regional lab of OIE lab), Mycoplasma gallisepticum (Cornell University Diagnostic Lab., New York, NY, USA), and six H9 real-time RT-PCR negative samples from apparently healthy chickens were used to determine the assay cross-reactivities. Thirty tracheal swabs were collected from field cases in Egypt and twelve negative tracheal swabs from specific pathogen-free (SPF) chicks and apparently healthy chickens were used to test the clinical performance of H9 RT-RPA assay compared to real-time RT-PCR. The samples varied from strong cycle threshold 13 (13 CT) to very weak sensitive samples (>35 CT). The real-time RT-PCR was performed using a Quantitect probe RT-PCR kit (Qiagen, Valencia, CA, USA) and using previously published oligonucleotides [28] . Linear regression analysis using PRISM (Graphpad Software Inc. version 6.0 Mac, San Diego, CA, USA) were applied to determine the correlation between real-time RT-PCR CT values and H9 RT-RPA TT. The RT-RPA TT was determined using the Tube Scanner Software (Qiagen, Lake Constance, Germany) as the first derivatives of the measured fluorescence signal in real-time. The value of the negative control was used as a cut-off value. The clinical sensitivity and specificity of the RT-RPA were determined using the standard formula published previously [29] . Linear regression analysis was performed using PRISM (Graphpad Software Inc. version 6.0 Mac, San Diego, CA, USA) by considering each Y value as an individual point with a 95% confidence interval value. An efficient primer set is crucial for the optimization of the RT-RPA assay. Three primers/probe combinations targeting the HA2 region of H9 (A/chicken/Egypt/1373Vd/ 2013(H9N2) were screened for their ability to amplify 240-280 pb of 10 5 EID 50 per RT-RPA reaction mixture (Table 1) . Primer pair H9 RPA-F1+ H9 RPA-R1 yielded the best amplification with signals emerging at 5.3 min among all the primer combinations ( Figure 1A) . The fluorescence amplitude of H9 RPA-F1+ H9 RPA-R1 was consistently the highest among all the primer pairs tested. Thus, this primer set (H9 RPA-F1+ H9 RPA-R1) was used to establish the RT-RPA assay and used for further assay validation. To determine the analytical sensitivity of H9 RT-RPA assay, a dilution range of 10 5 −10 0 molecules/µL of the H9 RNA standard was used ( Figure 1B) . When testing the 10 EID 50 range primer H9 RPA-F1+ H9 RPA-R1 also detected 10 EID 50 /mL in 8 min. The sensitivity of the real-time RT-PCR was 10 10 EID 50 /mL. Semi-logarithmic regression of the data collected from eight H9 RT-RPA test runs on the RNA standard using PRISM. It yielded results between 5-8 min ( Figure 2 ) and probit regression was not applied because the H9 RT-RPA detected eight times out of eight in all dilutions. of the real-time RT-PCR was 10 10 EID50/mL. Semi-logarithmic regression of the data collected from eight H9 RT-RPA test runs on the RNA standard using PRISM. It yielded results between 5-8 min ( Figure 2 ) and probit regression was not applied because the H9 RT-RPA detected eight times out of eight in all dilutions. (A) (B) Figure 1 . Primer combination testing using 10 5 EID50 per RT-RPA reaction mixture (A). Analytical sensitivity of H9 RT-RPA using standard virus of titer 10 5 EID50/mL using a dilution range down to 1 EID50/mL (B). The combination H9 RPA-F1+ H9 RPA-R1+ H9 exo-probe was detected down to one RNA molecule. The discontinuity at 3 min 50 s due to the necessary mixing step interrupting fluorescence measurement. Primer combination testing using 10 5 EID 50 per RT-RPA reaction mixture (A). Analytical sensitivity of H9 RT-RPA using standard virus of titer 10 5 EID 50 /mL using a dilution range down to 1 EID 50 /mL (B). The combination H9 RPA-F1+ H9 RPA-R1+ H9 exo-probe was detected down to one RNA molecule. The discontinuity at 3 min 50 s due to the necessary mixing step interrupting fluorescence measurement. When testing the specificity of H9 RT-RPA against other poultry pathogens producing respiratory manifestations, including aIAVs H5N2, H7N1, ILTV, IBV, NDV, and mycoplasma, only H9N2 was detected, indicating that the primers H9 RPA-F1+ H9 RPA-R1 were highly specific (Figure 3 ). In addition, no unspecific amplification was detected in control negative samples from SPF and apparently healthy chickens. When testing the specificity of H9 RT-RPA against other poultry pathogens producing respiratory manifestations, including aIAVs H5N2, H7N1, ILTV, IBV, NDV, and mycoplasma, only H9N2 was detected, indicating that the primers H9 RPA-F1+ H9 RPA-R1 were highly specific (Figure 3 ). In addition, no unspecific amplification was detected in control negative samples from SPF and apparently healthy chickens. Validation of the RT-RPA assay compared to RT-PCR assay was evaluated in thirty clinical samples. The results of H9 RT-RPA were detected in about 3-7 min in high and low virus load samples. The sensitivity of both the H9 RT-RPA and real-time RT-PCR assays was 100%. Linear regression analysis of H9 RT-RPA threshold time and PCR-cycle threshold was performed (Figure 4) , yielding a R square value of 0.12. This weak relationship between H9 RT-RPA and real-time RT-PCR is due to the speed of the RPA assay. Avian influenza virus subtype H9N2 is prevalent in Egypt and represents a large portion of the avian influenza subtypes detected among domestic poultry. Rapid field diagnosis of H9N2 subtype aIAVs is essential to reduce virus spread, economic losses, and human infections. However, real-time RT-PCR is the method of choice for the detection of avian influenza [28] . It is difficult to use in field conditions because of complex and costly instruments. Therefore, in this study we developed RT-RPA assay for rapid, sensitive, and specific on-site detection of the HA gene. Primer design in the RPA assay is still a big bottleneck, as apart from some guidelines, rules are not described and automated software design is, as yet, impossible [25] . Therefore, several primes were tested before selecting the best primer combination. Nine possible combinations were screened for sensitive amplification of the H9N2 viral RNA standard. Only the H9 RPA-F1+ H9 RPA-R1 primers produced a limit of detection of one EID50/mL. The H9N2 RT-RPA assay is a highly specific assay because only the viral RNA of H9N2 viruses were amplified. The nucleic acid of other respiratory pathogens in poultry, as well as specific pathogen-free healthy chickens, were scored negative in the H9 RT-RPA assay. The oligonucleotides of the developed assay were placed in a very conserved and specific region as done previously in the real-time RT-PCR [28] . The H9N2 RT-RPA assay correctly detected all real-time RT-PCR positive chicken samples (n = 30). Many Avian influenza virus subtype H9N2 is prevalent in Egypt and represents a large portion of the avian influenza subtypes detected among domestic poultry. Rapid field diagnosis of H9N2 subtype aIAVs is essential to reduce virus spread, economic losses, and human infections. However, real-time RT-PCR is the method of choice for the detection of avian influenza [28] . It is difficult to use in field conditions because of complex and costly instruments. Therefore, in this study we developed RT-RPA assay for rapid, sensitive, and specific on-site detection of the HA gene. Primer design in the RPA assay is still a big bottleneck, as apart from some guidelines, rules are not described and automated software design is, as yet, impossible [25] . Therefore, several primes were tested before selecting the best primer combination. Nine possible combinations were screened for sensitive amplification of the H9N2 viral RNA standard. Only the H9 RPA-F1+ H9 RPA-R1 primers produced a limit of detection of one EID 50/ mL. The H9N2 RT-RPA assay is a highly specific assay because only the viral RNA of H9N2 viruses were amplified. The nucleic acid of other respiratory pathogens in poultry, as well as specific pathogen-free healthy chickens, were scored negative in the H9 RT-RPA Vet. Sci. 2021, 8, 134 8 of 10 assay. The oligonucleotides of the developed assay were placed in a very conserved and specific region as done previously in the real-time RT-PCR [28] . The H9N2 RT-RPA assay correctly detected all real-time RT-PCR positive chicken samples (n = 30). Many samples with very high CT values around 38 in real-time RT-PCR were identified as positive by RT-RPA in less than 7 min, which is an indication of the high sensitivity of the developed assay. A correlation between the CT values of the real-time RT-PCR and TT values of the RT-RPA was not observed due to the explosive nature of the RPA reaction, which outruns the repetitive, regular amplification cycles of the PCR reaction [30] . Another promising isothermal application is the loop-mediated isothermal amplification (RT-LAMP) assay [31] . Compared to LAMP, the H9 RT-RPA is faster (less than 10 min in H9 RT-RPA, while at least 30 min is needed in RT-LAMP). Moreover, the number of primers is two in RPA and four in RT-LAMP [31] . Recently, RT-RPA-combined lateral flow dipstick (FLD) assay was developed for the detection of the H9 gene [24] . Compared to RT-RPA-FLD assay, our probe-based RPA assay is fast (7 min) because it can generate real-time amplification results in less than 20 min without an additional process after amplification. In addition, the clinical performance of H9 RT-RPA is slightly better than H9 RT-RPA-FLD as the agreement of the detection results between RT-RPA-LFD and conventional RT-PCR was 95.8% [24] . Recently, insulated isothermal PCR (iiPCR) devices were developed and assessed for the detection of avian influenza. The field-deployable POCKIT Micro DUO Nucleic Acid Analyzer needs 45 min, while the POCKIT Central Nucleic Acid Analyser processes results in 85 min to perform an iiPCR analysis [32] . In terms of time to result, both devices are still not as fast as a probe-based RPA assay under field conditions. Recent phylogenetic analyses show that H9N2 can be classified into three main lineages, each showing lineage-specific evolution. For the Egyptian strains, the HA segment sequences targeted by the assay described here form a distinctive subclade in the Asian-African lineage [33] . The assay designed specifically for this subclade should therefore not be used for the detection of other subclades. RPA primers are known to tolerate up to 9 mismatches in the target sequence [34] , and indeed, in some of our own work, RPA was shown to be very robust in detecting variant FMDV genotypes despite a considerable number of mismatches between genotypes [20] . Nevertheless, regular sequencing of local strains and alignment with the amplicon, as well as testing the viral RNA of evolving H9N2 strains, will be crucial to keep the presented RT-RPA amplicon up to date to avoid false negatives in the future. In conclusion, the developed H9 RT-RPA is rapid, simple, and sensitive for the on-site detection of H9N2 aIAVs. We have previously designed a "diagnostics-in-a-suitcase" for several pathogens [20, 30, 35] , which can be applied for rapid detection of the virus under field settings, in order to start immediate control measures, nevertheless, according to national Egyptian law, all positive samples must be confirmed by governmental institutions. The Viruses and Their Replication Structure and assembly of the influenza A virus ribonucleoprotein complex A new approach for diagnosis of bovine coronavirus using a reverse transcription recombinase polymerase amplification assay A Global Perspective on H9N2 Avian Influenza Virus Influenza virus evolution, host adaptation, and pandemic formation Molecular characterization and receptor binding specificity of H9N2 avian influenza viruses based on poultry-related environmental surveillance in China between Active surveillance and genetic evolution of avian influenza viruses in Egypt Challenge for One Health: Co-Circulation of Zoonotic H5N1 and H9N2 Avian Influenza Viruses in Egypt H9N2 influenza A virus circulates in H5N1 endemically infected poultry population in Egypt. Influenza Other Respir Avian influenza viruses (AIVs) H9N2 are in the course of reassorting into novel AIVs The avian influenza H9N2 at avian-human interface: A possible risk for the future pandemics Novel reassortant H9N2 viruses in pigeons and evidence for antigenic diversity of H9N2 viruses isolated from quails in Egypt Avian Influenza Virus Subtype H9N2 Affects Intestinal Microbiota, Barrier Structure Injury, and Inflammatory Intestinal Disease in the Chicken Ileum Pathological Alterations in Respiratory System During Co-infection with Low Pathogenic Avian Influenza Virus (H9N2) and Escherichia Coli in Broiler Chickens Insights into genetic diversity and biological propensities of potentially zoonotic avian influenza H9N2 viruses circulating in Egypt Epidemiology, ecology and gene pool of influenza A virus in Egypt: Will Egypt be the epicentre of the next influenza pandemic? Virulence Influenza in Manual of Diagnostic Tests and Vaccines for Terrestrial Animals Terrestrial Manual Development of reverse transcription recombinase polymerase amplification assay for avian influenza H5N1 HA gene detection A portable reverse transcription recombinase polymerase amplification assay for rapid detection of foot-andmouth disease virus Rapid Detection of Avian Influenza A Virus (H7N9) by Lateral Flow Dipstick Recombinase Polymerase Amplification Reverse transcription recombinase polymerase amplification with lateral flow dipsticks for detection of influenza A virus and subtyping of H1 and H3 Combination of multiplex reverse transcription recombinase polymerase amplification assay and capillary electrophoresis provides high sensitive and high-throughput simultaneous detection of avian influenza virus subtypes Development of a reverse transcription recombinase polymerase amplification combined with lateral-flow dipstick assay for avian influenza H9N2 HA gene detection Development of a panel of recombinase polymerase amplification assays for detection of biothreat agents Development and evaluation of a broadly reactive reverse transcription recombinase polymerase amplification assay for rapid detection of murine norovirus Co-infection of Staphylococcus aureus or Haemophilus paragallinarum exacerbates H9N2 influenza A virus infection in chickens Phylogenetic and molecular characteristics of Eurasian H9 avian influenza viruses and their detection by two different H9-specific RealTime reverse transcriptase polymerase chain reaction tests Understanding and using sensitivity, specificity and predictive values Suitcase Lab for Rapid Detection of SARS-CoV-2 Based on Recombinase Polymerase Amplification Assay Development of reverse transcription loop-mediated isothermal amplification for rapid detection of H9 avian influenza virus Evaluation of insulated isothermal PCR devices for the detection of avian influenza virus Genetic Characteristic and Global Transmission of Influenza A H9N2 Virus Influence of sequence mismatches on the specificity of recombinase polymerase amplification technology Diagnostics-in-a-Suitcase: Development of a portable and rapid assay for the detection of the emerging avian influenza A (H7N9) virus We acknowledge the support of the Open Access Publication Funds of the University of Goettingen, Germany. The authors declare no conflict of interest.