key: cord-0064908-gpa191oe authors: Baki, Abdulkader; Remmo, Amani; Löwa, Norbert; Wiekhorst, Frank; Bleul, Regina title: Albumin-Coated Single-Core Iron Oxide Nanoparticles for Enhanced Molecular Magnetic Imaging (MRI/MPI) date: 2021-06-09 journal: Int J Mol Sci DOI: 10.3390/ijms22126235 sha: e951d4bd3588edd80452169fe5dba62cc8b92708 doc_id: 64908 cord_uid: gpa191oe Colloidal stability of magnetic iron oxide nanoparticles (MNP) in physiological environments is crucial for their (bio)medical application. MNP are potential contrast agents for different imaging modalities such as magnetic resonance imaging (MRI) and magnetic particle imaging (MPI). Applied as a hybrid method (MRI/MPI), these are valuable tools for molecular imaging. Continuously synthesized and in-situ stabilized single-core MNP were further modified by albumin coating. Synthesizing and coating of MNP were carried out in aqueous media without using any organic solvent in a simple procedure. The additional steric stabilization with the biocompatible protein, namely bovine serum albumin (BSA), led to potential contrast agents suitable for multimodal (MRI/MPI) imaging. The colloidal stability of BSA-coated MNP was investigated in different sodium chloride concentrations (50 to 150 mM) in short- and long-term incubation (from two hours to one week) using physiochemical characterization techniques such as transmission electron microscopy (TEM) for core size and differential centrifugal sedimentation (DCS) for hydrodynamic size. Magnetic characterization such as magnetic particle spectroscopy (MPS) and nuclear magnetic resonance (NMR) measurements confirmed the successful surface modification as well as exceptional colloidal stability of the relatively large single-core MNP. For comparison, two commercially available MNP systems were investigated, MNP-clusters, the former liver contrast agent (Resovist), and single-core MNP (SHP-30) manufactured by thermal decomposition. The tailored core size, colloidal stability in a physiological environment, and magnetic performance of our MNP indicate their ability to be used as molecular magnetic contrast agents for MPI and MRI. Molecular imaging provides an integrative technology to study biological processes using non-invasive visualization of specific molecules in vivo [1] with the aim of early disease diagnosis and treatment evaluation [2] . To this end, numerous imaging techniques have been developed for molecular imaging such as magnetic resonance imaging (MRI) [1] , positron emission tomography (PET) [3] , computed tomography (CT) [4] , single-photon emission computed tomography (SPECT) [5, 6] , or ultrasound (US) [7] . Aside from the physical principle (detection of frequency, radionuclides, emitted light, X-ray, etc.), these modalities are different regarding invasiveness and cost-effectiveness. MRI relies on detecting the nuclear magnetic resonance signal of protons of the hydrogen atom 1 H after applying radiofrequency pulses. Therefore, MRI is not specific to molecules and requires the use of contrast agents or tracers to provide specificity and sensitivity for molecular imaging. Due to their magnetic properties, contrast agents such as paramagnetic Gd-compounds can shorten the T 1 (or longitudinal) and T 2 (or transverse) relaxation time of neighboring water protons. These effects increase the signal intensity of 3 of 19 of nucleation and particle growth can be isolated as a function of distance. The position where initial mixing induces nucleation is spatially separated from the particle growth occurring in the ripening zone. Due to in situ stabilization during this microfluidic production process, electrostatically stable dispersed single-core MNP in an aqueous medium are obtained. As described in the literature, alternative approaches, e.g., laser target evaporation from bulk material, can also produce stable aqueous magnetic nanofluids even without the need for an electrostatic stabilizer [34] . Coating with a double layer of oleic acid of magnetic nanoparticles obtained by combustion synthesis was reported as a biocompatible strategy for self-stabilizing particle dispersions in water [35] . Stable aqueous nanoparticle dispersions provide a safe starting product for biomedical development. Further surface modification can be performed straightforwardly by coating without preceding phase transfer. MNP surface characteristics play a key role in signal generation in medical imaging, as they influence the dispersion stability in the physiological environment and act as a linker for further functionalization. Moreover, the surface coating of iron oxide MNP is reported to improve biocompatibility and reduce cytotoxic effects that can be caused by reactive oxygen species (ROS) [36] [37] [38] . Potent agents for molecular imaging are supposed to prevent non-specific interaction with the biological system, e.g., with serum proteins, high ionic strength, blood and endothelial cells, while specifically targeting biological markers or receptors. The attachment of specific ligands helps to identify signal molecules or bind to and detect, e.g., cancer cells that overexpress typical receptors. The biocompatibility, non-toxicity, and stability of MNP are crucial for in vivo applications. The MNP surface can be modified with different strategies utilizing macromolecules with different functional groups such as dextran [39, 40] , polyethylene glycol (PEG) [41, 42] , or numerous peptides [43] . Serum albumin is a main blood plasma protein with significant vital functions such as maintaining the pH and osmotic pressure of blood and exhibit excellent stability in physiological systems [44, 45] . Moreover, the functional groups existing in albumin such as amino and carboxy groups enable it to bind different drug-targeting ligands. For instance, Abraxane ® , an albumin-paclitaxel nanoparticle, is a clinically approved chemotherapeutic drug conjugate. Its efficacy was confirmed in clinical trials and showed a significant activity in pancreatic cancer patients [46] and antitumoral effects in women with breast cancer [47] . Mesken et al. have investigated plasmid-loaded albumin nanoparticles for cellular uptake and gene delivery [48] . Due to its similar biological function and chemical composition, bovine serum albumin (BSA) as analogue to human serum albumin (HSA) is a widely used component for investigations and developments in the field of drug delivery and cancer diagnostic [49] . Many research groups have also used BSA for MNP surface coating after synthesis, mainly resulting in clusters of small MNP in a size range between 4 and 10 nm [50] [51] [52] [53] . Kalidasan et al. have investigated the conjugation of BSA to 10 and 30 nm non-spherical, rhombus-shaped MNP using cetyl trimethyl ammonium bromice (CTAB) and 3-Amino-Trimethoxysilane (APTM) as linker molecules. Due to the improved colloidal stability of these BSA-MNP, the specific absorption rate (SAR) values for magnetic hyperthermia could be increased from 1700 W/g for MNP without BSA to 2300 W/g for BSA-MNP [54] . To conclude, for a successful surface modification, not only does the coating material have to be carefully selected, but also effects occurring due to the required post-synthesis procedures such as phase transfer or purification steps might lead to clustering effects or undesirable residue of solvents that can be disadvantageous for their application as contrast agents. In this study, we demonstrate that surface modification of continuously synthesized single-core MNP with BSA effectively improves their stability and ensures a robust performance as tracers in molecular imaging. Manufacturing and surface modification were carried out in an aqueous medium without the addition of harmful chemicals or the need for phase transfer. The as-synthesized (tannin-coated) and BSA-coated MNP were comprehensively studied regarding changes in their colloidal stability and magnetic properties at different physiological relevant salt (NaCl) concentrations. Average size, size distribution, and particle morphology were investigated by transmission electron microscopy (TEM) and differential centrifugal sedimentation (DCS). Changes in particle surface were studied by Zeta potential measurements and gel electrophoresis. Using AC-susceptibility (ACS) measurements of the linear magnetic susceptibility, changes in the hydrodynamic properties of the MNP systems have been investigated. To determine the MPI performance of the MNP, we used magnetic particle spectroscopy (MPS). MPS detects the non-linear dynamic magnetic response of MNP exposed to an alternating magnetic field. Since it is based on the same physical mechanisms, it can be considered zero-dimensional MPI. Furthermore, to evaluate the capability of the MNP systems as contrast agents in MRI, nuclear magnetic resonance (NMR) relaxivity measurements were carried out. For comparison, MPS and NMR measurements of the two commercial MNP systems Resovist (multi-core system, MRI liver contrast agent) and SHP-30 (single-core nanoparticle system synthesized by thermal decomposition, preclinical research) have been included. The capability of a continuous micromixer technique to synthesize aqueous single-core MNP with diameters of up to 40 nm has been demonstrated recently [32] . By adjusting the two synthesis parameters T S = 55 • C and residence time t R = 4 min, MNP with mean core size diameter of about d c = 30 nm were found to possess high performance in MRI and MPI. Based on this MNP system, further improvement using surface modification with a BSA protein coating is envisaged regarding stability in a physiological environment and magnetic performance for molecular imaging applications. We show that centrifugation significantly improves the magnetic performance of the as-synthesized MNP in Section 2.1, demonstrate the structural and magnetic changes by surface modification using a BSAcoating in Section 2.2, and present the steady stability of the BSA-coated system in different physiological saline concentrations together with the maintenance of the powerful MRI and MPI imaging capability of this MNP system. For comparison, all measurements were performed with as-synthesized MNP (tannic acid coated) without any further surface modification and the centrifuged MNP as well. Furthermore, we included data of the two commercial systems Resovist and SHP-30. Our continuous micromixer synthesis approach provides stable dispersions of singlecore nanoparticles with narrow size distribution, as shown in Figure 1a . Spherical singlecore particles with a mean diameter d c of 27.6 ± 5.5 nm were determined by TEM analysis of the as-synthesized MNP (containing the basic tannic acid coating). The apparent hydrodynamic diameter d h distribution determined by DCS shows a narrow peak with a maximum at 26.5 nm close to, but slightly smaller than, the core diameter obtained by TEM. Notably, the hydrodynamic size distribution obtained by DCS for the as-synthesized and centrifuged MNP shown in Figure 1a assumes a density of pure magnetite neglecting the decrease in density resulting from the organic tannic acid coating on the surface. This leads to slightly shifting the hydrodynamic diameters determined by DCS to smaller values (as the real density of the particles is smaller than the assumed magnetite density used for the data analysis). Furthermore, a minor fraction with dh > 30 nm of MNP attributed to agglomerates or superstructures is observed in DCS. These larger entities might affect the signal generation in magnetic imaging due to undesired particle-particle interaction of the particle magnetic moments. Therefore, we performed an additional centrifugation prior to BSAcoating and analyzed the resulting structural and magnetic changes of the particle fractionation. DCS measurements of the centrifuged MNP system confirm the successful separation of agglomerates with dh > 80 nm, as illustrated in Figure 1a . The centrifugation results in a yield reduction of about 35%, as estimated from the corresponding MNP content of the individual fractions determined by iron concentration analysis. The small shoulder right to the main peak in DCS still indicates the tendency to form small superstructures such as dimers or trimers, which in our experience is reversible. The DCS results are confirmed by TEM, where no clustering is found in TEM images of the MNP system after centrifugation, as shown in the next section (see Figure 2a) . The effect of centrifugation is also expressed in the magnetic properties of the MNP. As displayed in Figure 1b , the MPS measurements showed an increase of about 37% of the specific (MPS moment normalized to iron content) A3* amplitude from 21.3 Am 2 /kg(Fe) to 33.9 Am 2 /kg(Fe) by centrifugation. This indicates the remarkable enhancement of signal sensitivity as a consequence of isolating stable single-core MNPs from the fraction-containing agglomerates. The MNP concentration-independent shape parameter A5/A3 showed a slight increase from 34.9% to 36.4%. Generally, this increase of the A5/A3 parameter results in a better MPI performance and image resolution. The centrifuged MNP system was then used for surface modification by BSA-coating, as described in the next section. Furthermore, a minor fraction with d h > 30 nm of MNP attributed to agglomerates or superstructures is observed in DCS. These larger entities might affect the signal generation in magnetic imaging due to undesired particle-particle interaction of the particle magnetic moments. Therefore, we performed an additional centrifugation prior to BSA-coating and analyzed the resulting structural and magnetic changes of the particle fractionation. DCS measurements of the centrifuged MNP system confirm the successful separation of agglomerates with d h > 80 nm, as illustrated in Figure 1a . The centrifugation results in a yield reduction of about 35%, as estimated from the corresponding MNP content of the individual fractions determined by iron concentration analysis. The small shoulder right to the main peak in DCS still indicates the tendency to form small superstructures such as dimers or trimers, which in our experience is reversible. The DCS results are confirmed by TEM, where no clustering is found in TEM images of the MNP system after centrifugation, as shown in the next section (see Figure 2a) . The effect of centrifugation is also expressed in the magnetic properties of the MNP. As displayed in Figure 1b , the MPS measurements showed an increase of about 37% of the specific (MPS moment normalized to iron content) A 3 * amplitude from 21.3 Am 2 /kg(Fe) to 33.9 Am 2 /kg(Fe) by centrifugation. This indicates the remarkable enhancement of signal sensitivity as a consequence of isolating stable single-core MNPs from the fractioncontaining agglomerates. The MNP concentration-independent shape parameter A 5 /A 3 showed a slight increase from 34.9% to 36.4%. Generally, this increase of the A 5 /A 3 parameter results in a better MPI performance and image resolution. The centrifuged MNP system was then used for surface modification by BSA-coating, as described in the next section. The effect of BSA-coating on the magnetic properties of the MNP was investigated by ACS and MPS measurements. ACS measurements in Figure 3 display the typical shape observed for a colloidal MNP system with a step-like decrease of the real part χ′ with increasing frequency (Figure 3a ) and a distinct maximum in the imaginary part χ′′(f) of the complex linear susceptibility (Figure 3b ). The as-synthesized and centrifuged MNP show nearly identical spectra, only differing in the linear susceptibility amplitude χ0, which increases by about 26% from χ0 = 0.062 m³/kg(Fe) for the as-synthesized to 0.084 m³/kg(Fe) for the centrifuged MNP. This shows the improvement in the magnetic quality of the MNP without changing the fraction of sizes responsible for the dynamic magnetic behavior. In other words, the increase in amplitude is attributed to the effective removal of the aggregates by centrifugation, which, due to their inhibited Brownian rotation, do not contribute notably to the linear susceptibility in the measured frequency range. The χ′′ (f) curves of both uncoated systems have the maximum at nearly the same frequency of f = 5.92(2) kHz, indicating that by centrifugation the hydrodynamic size distribution of the free MNP is not changed in agreement with the DCS measurements after centrifugation (see Figure 1a ). The increase in hydrodynamic diameter by adding the BSA-layer was apparent in ACS measurements as a shift of the peak position of the imaginary part χ′′ from about 5 kHz to about 1 kHz (see Figure 3b ). The increased hydrodynamic diameter of the BSAcoated particles augments the rotational inertia of the moments to follow the oscillating excitation field, resulting in the observed shift of the χ′′ peak towards lower frequencies. At the same time the susceptibility amplitude χ0 (χ′ for f⟶0) is slightly decreased by about 14% after BSA-coating, still remaining above the amplitude of the as-synthesized MNP ( Figure 3a ). This indicates the effective coating of the MNP by the BSA layer. Generally, iron oxide nanoparticles are stabilized in situ during continuous micromixer synthesis with tannic acid, which acts mainly as an electrostatic stabilizing agent. However, high salt concentrations as present in a physiological environment (typically 150 mM NaCl, isotonic saline) strongly affect the colloidal stability of electrostatically stabilized nanoparticles. Thus, a further modification, preferably with a steric stabilizer, is required. In biomedical and pharmaceutical applications, biocompatible synthetic as well as biologic polymers are commonly used, e.g., polyethylene glycol and copolymers, polypeptides or proteins, and polysaccharides [55, 56] . In this study, bovine serum albumin (BSA) was chosen for surface modification to prevent aggregation of the single-core magnetic nanoparticles. This blood plasma protein has high concentrations in blood and is known to form a protein corona to particles injected in the blood stream very rapidly [57] . BSA-coating is a frequently reported strategy [50] to prevent non-specific interaction and enhance colloidal stability and biocompatibility of nanoformulations. Here, we evaluated the effect of BSA-coating as further surface modification on the structural and magnetic imaging properties and compared them with the corresponding behavior of the uncoated systems. TEM analysis of the original, centrifuged sample compared to the BSA-treated sample confirmed the successful protein coating (Figure 2a-d) . The size and shape of both samples were relatively homogenous and displayed mostly spherical single-core particles. No significant changes of the cores were observed after the coating procedure. The mean core size of centrifuged sample was estimated by automatic image analysis and showed 27.7 nm with relative standard deviation of 0.17 ( Figure 2e ). Though the presence of protein coating is poorly visible in TEM analysis due to the low contrast of BSA, the effect of the coating increasing the interparticle distances is clearly seen in the images (Figure 2a Changes in the surface characteristics of the MNP after BSA-coating were investigated by zeta potential measurements and agarose gel electrophoresis. The latter technique is commonly used for the separation and analysis of biomacromolecules, e.g., oligonucleotides. Separation depends generally on the (surface) charge as well as the molecular weight. It has been shown that gel electrophoresis is also a useful tool to analyze surface charge, size, and stability of nanoparticles [58] . The as-synthesized MNP possess a high negative surface charge with a zeta potential of about −51 mV. This highly negative value can be explained by anionic polyphenolic groups of the tannic acid coating. The BSAcoated sample displayed a value of about −25 mV in distilled water, which agrees with values for BSA at pH 6.5 in the literature [34] . Generally, sufficient electrostatic stabilization of nanoparticles can be assumed for samples with a zeta potential that exceeds 20 mV, irrespective of their sign [59] . Apparently, the MNP without BSA-coating did not pass the electrophoresis gel, as shown in Figure 2g . This was attributed to the high affinity of tannic acid to polysaccharide that might have caused crosslinking and hydrogel formation, as reported in the literature [60] . In contrast, BSA-coated samples displayed significant migrations through the gel, as displayed in Figure 2g . This qualitative finding evidences that BSA-coating was successful and changed the surface characteristics of the MNP. The effect of BSA-coating on the magnetic properties of the MNP was investigated by ACS and MPS measurements. ACS measurements in Figure 3 display the typical shape observed for a colloidal MNP system with a step-like decrease of the real part χ with increasing frequency (Figure 3a ) and a distinct maximum in the imaginary part χ (f ) of the complex linear susceptibility (Figure 3b ). The as-synthesized and centrifuged MNP show nearly identical spectra, only differing in the linear susceptibility amplitude χ 0 , which increases by about 26% from χ 0 = 0.062 m 3 /kg(Fe) for the as-synthesized to 0.084 m 3 /kg(Fe) for the centrifuged MNP. This shows the improvement in the magnetic quality of the MNP without changing the fraction of sizes responsible for the dynamic magnetic behavior. In other words, the increase in amplitude is attributed to the effective removal of the aggregates by centrifugation, which, due to their inhibited Brownian rotation, do not contribute notably to the linear susceptibility in the measured frequency range. The χ (f ) curves of both uncoated systems have the maximum at nearly the same frequency of f = 5.92(2) kHz, indicating that by centrifugation the hydrodynamic size distribution of the free MNP is not changed in agreement with the DCS measurements after centrifugation (see Figure 1a ). As displayed in Figure 4a , the MPS specific amplitude decreased slightly from A3* = 33.9 Am 2 /kg(Fe) to 26 Am 2 /kg(Fe) after BSA-coating, which is still a remarkably high value that is three times higher than the value A3* = 8.7 Am 2 /kg(Fe) of Resovist. The reason for The increase in hydrodynamic diameter by adding the BSA-layer was apparent in ACS measurements as a shift of the peak position of the imaginary part χ from about 5 kHz to about 1 kHz (see Figure 3b ). The increased hydrodynamic diameter of the BSA-coated particles augments the rotational inertia of the moments to follow the oscillating excitation field, resulting in the observed shift of the χ peak towards lower frequencies. At the same time the susceptibility amplitude χ 0 (χ for f →0) is slightly decreased by about 14% after BSA-coating, still remaining above the amplitude of the as-synthesized MNP (Figure 3a) . This indicates the effective coating of the MNP by the BSA layer. As displayed in Figure 4a , the MPS specific amplitude decreased slightly from A 3 * = 33.9 Am 2 /kg(Fe) to 26 Am 2 /kg(Fe) after BSA-coating, which is still a remarkably high value that is three times higher than the value A 3 * = 8.7 Am 2 /kg(Fe) of Resovist. The reason for the A 3 * reduction is assumed to again be the increase of hydrodynamic diameter by the additional BSA-coating reducing to some extent the capability of the magnetic moments of the MNP to follow the excitation magnetic field, diminishing the resulting magnetic response in MPS. Thus, both the observed reduction of the linear magnetic AC susceptibility amplitude χ 0 and the measured decrease in the MPS signal amplitude A 3 * are caused by the increase of hydrodynamic diameter after BSA-coating. As displayed in Figure 4b , the A 5 /A 3 ratio remained nearly constant at the comparable high level of 35.8% for BSA-coated MNP (compared to 36.4% for MNP without BSA), indicating that the BSA-coating will maintain the MPI performance. To assess the performance of BSA-coated MNP in the second magnetic imaging modality, MRI, we determined the NMR relaxivities r1 and r2, as shown in Figure 5 . The relaxation rates R1 = 1/T1 and R2 = 1/T2 as a function of iron concentration c(Fe) measured at B0 = 1.5 T are shown in Figure 5 for as-synthesized, centrifuged, and BSAcoated MNP. We obtained relaxivities of r1 = 11.6(9) and r2 = 482(8) L mol −1 s −1 , for as-synthesized MNP, r1 = 13.6(6) and r2 = 620(7) L mol −1 s −1 for centrifuged MNP, and r1 = 6.4(1) and r2 = 600(1) L mol −1 s −1 for BSA-coated MNP, indicating their high capability as negative contrast agents. For the MRI liver contrast agent Resovist, values of r1 = 7.4 and r2 = 95 L mol −1 s −1 are reported in literature at the same field B0 = 1.5 T [1, 62] . The r2 relaxivity is about six times higher than Resovist. Additionally, the high ratio between transversal and longitudinal relaxivities r2/r1 indicates the efficiency of a T2 as contrast agent. Hence, the Similar effects of reduced MPS performance have been observed for MNP where the local viscosity has been increased, leading to the same increase of rotational inertia of MNP moments [61] . To assess the performance of BSA-coated MNP in the second magnetic imaging modality, MRI, we determined the NMR relaxivities r 1 and r 2 , as shown in Figure 5 . Table 1 . [1, 29] . Note that the uncertainty of a r1 or r2 value is denoted in brackets, e.g., 11.6(9) L·mol −1 ·s −1 is short-hand notation for 11.6 ± 0.9 L·mol −1 ·s −1 . Preserving the MNP stability in physiological systems is a key requirement for their in vivo clinical applicability [64] . Unprotected MNP exposed to serum proteins or isotonic salt concentrations will form aggregates and agglomerates with potential severe consequences for the biological system. Additionally, salt-induced agglomeration might affect the magnetic properties of MNP and thereby lower the diagnostic information of magnetic imaging modalities. In this section, we incubate BSA-coated MNP as well as as-synthesized MNP (tannic acid coating) at three different saline concentrations, c(NaCl) = 0.05, 0.10, and 0.15 mol/L, to evaluate the stability of MNP after short-(2 h) as well as long-term (1 day, 1 week) Figure 5 . Room temperature NMR relaxation rates R 1 (a) and R 2 (b) measurements as a function of iron concentration c(Fe) of as-synthesized, centrifuged, and BSA-coated MNP measured at 1.5 T. The relaxation rates are obtained by linear regression and drawn as straight lines; the corresponding for the r 1 and r 2 values are listed in Table 1 . Table 1 . Properties of the investigated MNP systems together with the two commercial MNP systems, Resovist and SHP-30 MNP. System information and coating are provided in the first two columns, followed by magnetic parameters obtained by MPS (amplitude of the 3 rd harmonic normalized to iron amount, A3*), ACS (initial susceptibility χ 0 ), and NMR (relaxivities r 1 and r 2 and the ratio r 2 /r 1 measured at 1.5 T). The relaxation rates R 1 = 1/T 1 and R 2 = 1/T 2 as a function of iron concentration c(Fe) measured at B 0 = 1.5 T are shown in Figure 5 for as-synthesized, centrifuged, and BSA-coated MNP. We obtained relaxivities of r 1 = 11.6(9) and r 2 = 482(8) L mol −1 s −1 , for as-synthesized MNP, r 1 = 13.6(6) and r 2 = 620(7) L mol −1 s −1 for centrifuged MNP, and r 1 = 6.4(1) and r 2 = 600(1) L mol −1 s −1 for BSA-coated MNP, indicating their high capability as negative contrast agents. For the MRI liver contrast agent Resovist, values of r 1 = 7.4 and r 2 = 95 L mol −1 s −1 are reported in literature at the same field B 0 = 1.5 T [1, 62] . The r 2 relaxivity is about six times higher than Resovist. Additionally, the high ratio between transversal and longitudinal relaxivities r 2 /r 1 indicates the efficiency of a T 2 as contrast agent. Hence, the coated MNP can be considered an alternative to Resovist with even better MR imaging performance. Interestingly, we observe a higher relaxivity for BSA-coated particles, which at first argues against classical theory, since the diffusing hydrogen protons are shielded from the magnetic core. However, there is the possibility that the BSA shell prolongs the residence time of the hydrogen protons near the magnetic core, thereby leading to a higher relaxivity. Monte Carlo simulations contribute to the understanding of the relationship between layer thickness and changes in relaxivity [63] . To summarize, the comprehensive characterization of BSA-coated MNP indicates their competitive high performance in MRI and MPI (Table 1 ). Compared to commercial systems, our BSA-coated MNP surpass Resovist in both imaging modalities. The r 2 relaxivity is about six times higher than Resovist. MPI signal amplitude A 3 * reaches that of SHP-30, a well-defined, commercial single-core MNP system manufactured by thermal decomposition and modified after phase transfer with an amphiphilic polymer. Preserving the MNP stability in physiological systems is a key requirement for their in vivo clinical applicability [64] . Unprotected MNP exposed to serum proteins or isotonic salt concentrations will form aggregates and agglomerates with potential severe consequences for the biological system. Additionally, salt-induced agglomeration might affect the magnetic properties of MNP and thereby lower the diagnostic information of magnetic imaging modalities. In this section, we incubate BSA-coated MNP as well as as-synthesized MNP (tannic acid coating) at three different saline concentrations, c(NaCl) = 0.05, 0.10, and 0.15 mol/L, to evaluate the stability of MNP after short-(2 h) as well as long-term (1 day, 1 week) incubation time. Colloidal stability changes impacting the hydrodynamic size distribution and aggregation were analyzed by DCS, while changes in magnetic properties were deducted from MPS measurements. The BSA-coated MNP remained highly stable over the complete observation time even at the highest saline concentration, c (NaCl) = 0.15 mol/L (Figure 6 ), without any noticeable aggregation visible in DCS. In contrast, the as-synthesized MNP without BSAcoating showed a slight increase in hydrodynamic diameter already at the lowest saline concentration (c(NaCl) = 0.05 mol/L) and rapid aggregation at higher saline concentration (c(NaCl) = 0.10 and 0.15 mol/L) independent of incubation time. As shown in Figure 7 , visual inspection by eye after one-week saline incubation revealed strong precipitation of the as-synthesized MNP, while the BSA-coated MNP appeared as a stable colloidal suspension. concentration (c(NaCl) = 0.05 mol/L) and rapid aggregation at higher saline concentration (c(NaCl) = 0.10 and 0.15 mol/L) independent of incubation time. As shown in Figure 7 , visual inspection by eye after one-week saline incubation revealed strong precipitation of the as-synthesized MNP, while the BSA-coated MNP appeared as a stable colloidal suspension. coating showed a slight increase in hydrodynamic diameter already at the lowest saline concentration (c(NaCl) = 0.05 mol/L) and rapid aggregation at higher saline concentration (c(NaCl) = 0.10 and 0.15 mol/L) independent of incubation time. As shown in Figure 7 , visual inspection by eye after one-week saline incubation revealed strong precipitation of the as-synthesized MNP, while the BSA-coated MNP appeared as a stable colloidal suspension. As shown in Figure 8 , MPS measurements confirm the results obtained from DCS measurements. The specific MPS amplitude of the MNP without BSA decreases from A 3 * = 33.9 to 24.4 Am 2 /km(Fe) already at the lowest saline concentration c(NaCl) = 0.05 mol/L, and almost a complete loss of signal can be observed at higher saline concentrations c(NaCl) = 0.10, 0.15 mol/L, independently of the incubation time (see Figure 8a ). Modification of MNP by BSA-coating preserved the magnetic signal properties. The A 3 * value remained constant at c(NaCl) = 0.05 and 0.10 mol/L and showed a slight decrease from A 3 * =26 Am 2 /kg(Fe) to 22.4 Am 2 /kg(Fe) at c(NaCl) = 0.15 mol/L. The A 5 /A 3 ratio shown in Figure 8b of BSA-coated MNP remained constant at a high level, exceeding 35% for all saline concentrations independent of incubation time. These high values indicate the high spatial resolution of the MNP and hence a high image quality in MPI. The uncoated MNP showed a significant reduction of the ratio A 5 /A 3 for the lower saline concentrations, slightly increasing again at c(NaCl) = 0.15 mol/L. Notably, A 5 /A 3 is independent of the number of MNP in the sample, and due to the very low A 3 * values of the uncoated MNP in a saline environment, this behavior is attributed to the magnetic response of a very small fraction of MNP (below 5% as estimated from the A 3 * drop) that are not completely aggregated or agglomerated and emphasizes the high sensitivity of MPS. Based on these promising results, an investigation of the behavior of BSA-coated MNP in different other physiological media such as plasma, full blood, or even living cells will follow soon. =26 Am 2 /kg(Fe) to 22.4 Am 2 /kg(Fe) at c(NaCl) = 0.15 mol/L. The A5/A3 ratio shown in Figure 8b of BSA-coated MNP remained constant at a high level, exceeding 35% for all saline concentrations independent of incubation time. These high values indicate the high spatial resolution of the MNP and hence a high image quality in MPI. The uncoated MNP showed a significant reduction of the ratio A5/A3 for the lower saline concentrations, slightly increasing again at c(NaCl) = 0.15 mol/L. Notably, A5/A3 is independent of the number of MNP in the sample, and due to the very low A3* values of the uncoated MNP in a saline environment, this behavior is attributed to the magnetic response of a very small fraction of MNP (below 5% as estimated from the A3* drop) that are not completely aggregated or agglomerated and emphasizes the high sensitivity of MPS. Based on these promising results, an investigation of the behavior of BSA-coated MNP in different other physiological media such as plasma, full blood, or even living cells will follow soon. With their physicochemical and magnetic properties, continuously synthesized BSAcoated MNP in aqueous phase offer a superior alternative as tracers for MRI and MPI compared to MNP prepared by other synthetic routes. Small and ultrasmall MNP are suboptimal candidates for MPI. Increasing the core size often leads to increasing magnetic particle-particle interactions with resulting aggregation. Hence, stabilizing the MNP with a suitable coating is crucial to shield these interactions. Choosing the coating material is Figure 8 . Colloidal stability of MNP in NaCl solution after different incubation times as measured by MPS. MPS parameter A 3 * (a) of uncoated (red symbols) and BSA-coated MNP (green symbols) at different NaCl concentrations after 2 h, 1 day, and 1 week of incubation (symbols from bright to dark with increasing time). Nearly no changes (less than 10%) of the specific MPS amplitude A 3 * were observed in the BSA-coated MNP, indicating colloidal stability up to physiological saline concentrations of 0.15 mol/L. By contrast, the uncoated MNP show a strongly reduced stability visible in the strong A 3 * reduction at NaCl concentrations below 0.10 mol/L. As for A 3 *, the corresponding parameter A 5 /A 3 (b) remains unchanged up to physiological NaCl concentration for BSA-coated MNP, while for uncoated MNP, a reduction in the parameter is visible. Since A 5 /A 3 is concentration-independent, only a very small fraction (below 5% as estimated from the A 3 * drop) of not completely aggregated MNP are contributing to A 5 /A 3 . With their physicochemical and magnetic properties, continuously synthesized BSAcoated MNP in aqueous phase offer a superior alternative as tracers for MRI and MPI compared to MNP prepared by other synthetic routes. Small and ultrasmall MNP are suboptimal candidates for MPI. Increasing the core size often leads to increasing magnetic particle-particle interactions with resulting aggregation. Hence, stabilizing the MNP with a suitable coating is crucial to shield these interactions. Choosing the coating material is significant as well. Here, not only the steric stabilization but also the behavior in the physiological environment has to be considered. Pegylation, the attachment of polyethylene glycol (PEG) on the particle surface, is common practice to improve the colloidal stability of nanoparticles in biomedical applications. Kandahar et al. investigated the functionalization of 25 nm single-core MNP with PEG in a time-consuming multi-step process after phase transfer to enhance blood circulation [42] . However, it is frequently reported that PEG can lead to pseudo allergic reactions in clinical applications and can provoke IgE-mediated reactions and recurrent anaphylaxis [65, 66] . Chanan-Khan et al. found a direct relation between complement activation and immediate hypersensitivity reactions after initial Doxil ® (PEGylated liposomal doxorubicin) dose [67] . Albumin is a safe and very efficient coating approach displaying generally high tolerability. It provides MNP protection from agglomeration mediated by blood constituents such as blood cells, proteins, and high salt concentrations. At the same time, protein coating on the MNP surface can prevent harmful effects of reactive oxygen species [38] . Moreover, the capability to add specific ligands to the functional amino or carboxy groups of the protein empowers BSA-coated MNP for further diagnostic and therapeutic medical applications. Iron oxide nanoparticles were produced continuously using micromixer set-up by precipitation of alkaline solutions of iron chloride in an aqueous medium, as previously reported in [32] . Briefly, solutions of iron chloride, sodium nitrate, and sodium hydroxide (all reagents were used without further purification, purity grade 98%, Sigma Aldrich, Darmstadt, Germany) were mixed in a caterpillar micromixer (Fraunhofer IMM, Mainz, Germany) with symmetric liquid ratios and piped in a 55 • C reaction loop with a residence time of 4 min. Tannic acid (1.7 kDa, Fluka, Schwerte, Germany) was added as a stabilizing agent. MNP were purified by removing unreacted educts and accessing the stabilizing agent via magnetic separation. Additional centrifugation of 50 mL of MNP dispersion filled falcon tubes at 3300 revolutions per minute (g-force = 2118 relative centrifugal force) for 15 min was used to remove aggregates and superstructure. The pellet was discarded, and the supernatant was taken for further surface modification. The iron concentration c(Fe) of the sample was determined photospectroscopically using the phenanthroline protocol (see Section 3.3 below). Finally, MNP were modified with a protein coating through incubation with 10 mg/mL BSA (Sigma Aldrich, Darmstadt, Germany) in a 50 mM, Ph ≈ 8.5, sodium bicarbonate buffer (Sigma Aldrich, Darmstadt, Germany) at 60 • C for 12 h. The sample was purified by magnetic separation with a LS-column (Miltenyi Biotec, Bergisch-Gladbach, Germany). After passing through the column, the BSA-coated MNP were washed five times with 3 mL sodium bicarbonate buffer to remove excess BSA in the sample and eluted in a 3 mL sodium bicarbonate buffer. To assess the colloidal stability, NaCl solution at three different saline concentrations (c(NaCl) = 0.05, 0.10, and 0.15 mol/L) was added to the centrifuged and BSA-coated MNP, and the resulting changes in hydrodynamic diameter were analyzed by DCS and magnetically by MPS measurements. Core size and shape were obtained by TEM measurements. Samples were prepared by placing a drop of the sample on a carbon-coated copper grid and left at room temperature to evaporate after applying a magnetic field for a short period of time (10 min) to accumulate the MNP. A Zeiss Libra 120 electron microscope (Zeiss, Oberkochen, Germany) at 120 kV acceleration voltage was used to perform the measurement. The images were taken by a CCD camera. The obtained images were evaluated using the open-source software ImageJ (National Institutes of Health, Bethesda, MD, USA) to calculate the mean diameter and standard deviation of the individual nanoparticles (N > 10,000). DCS (or analytical ultracentrifugation) offers detailed information on the dispersion properties of MNP in colloidal systems. In a DCS measurement, sedimentation properties of the particle are measured according to the hydrodynamic particle size distribution [68] ; the different size fractions can be differently accelerated in a gravitational field, leading to better fractionalization. Dynamic light scattering (DLS), the standard method to determine the hydrodynamic diameter, gave no results, since the absorption of the nanoparticles with the relatively large core and only a thin tannic acid coating layer was too strong (in contrast to other polymeric coatings such as PEG or dextran that scatter the excitation light well). Thus, no reliable correlation of the fluctuation of the particles could be detected, and size determination with light scattering was not reliably feasible. However, analytical centrifugation is a well-established method to determine size and size distributions, particularly for samples with larger densities such as iron oxide, and also to sensitively display different fractions of polymodal samples. Hence, agglomerated and single-core particles will be accurately detected compared to DLS. Since the density influences MNP sedimentation, a mean density of core (magnetite) and shell material (BSA-coating) of the MNP was taken into account to determine the hydrodynamic diameter by DCS. For BSA, we used a BSA density of ρ = 1.41 g/cm 3 [69] and a hydrodynamic radius of d h,BSA = 4 nm [63, 64] . Assuming a monolayer BSA-coating of 8 nm thickness, an MNP core size of d c = 28 nm, and a magnetite density ρ Fe3O4 = 5.2 g/cm 3 , a mean density ρ BSA-MNP = 2.45 g/cm 3 for BSAcoated MNP was calculated. DCS measurements (CPS Instruments Inc. Measurements, Darmstadt, Germany) were carried out at 20,000 rpm (=21,504 relative centrifugal force) after calibration with a silicon dioxide (SiO 2 ) standard (255 nm). Sucrose gradient was built up using 24% to 8% sucrose. Peak maximum and full width at half maximum (FWHM) were evaluated using Origin ® software (ADDITIVE Soft-und Hardware für Technik und Wissenschaft GmbH, Friedrichsdorf, Germany). Zeta potentials in aqueous dispersion were derived from electrophoretic mobility measurements using a Litesizer 500 (Anton Paar GmbH, Ostfildern, Germany). The measurements were carried out in an Anton Paar Omega cuvette at a temperature of 20 • C (temperature equilibration time 30 s). Automatic mode was used for conducting the measurements (automatically chosen parameters: runs processed: 100, adjusted voltage: 200 V). For data evaluation, the Smoluchowski approximation (Henry factor: 1.5) was chosen. Agarose gel electrophoresis was used to investigate the presence of protein on the surface of the MNP; 1% agarose gel (Carl Roth, Karlsruhe, Germany) was prepared by melting 1 g in 100 mL of 10 mM borat buffer (Sigma Aldrich, Darmstadt, Germany) (pH = 8.3). The mixture was heated using a microwave in intervals of 30 s until the agarose completely dissolved. The gel was poured into a mold with a comb and left for two hours to cool down to room temperature. The agarose gel was placed in an electrophoresis apparatus and a buffer was added to cover the gel. A total of 20 µL of the samples was mixed with 5 µL OrangeG dye (Carl Roth, Karlsruhe, Germany). A total of 20 µL of the mixture was then added to the gel. The power supply of the apparatus was turned on at 290 V and ran for 30 min. The iron concentration c(Fe) of the nanoparticle samples was determined photospectroscopically using the phenanthroline protocol [70] . A total of 10 µL of nanoparticles was dissolved in 20 µL hydrochloric acid (37%). After complete dissolution, 470 µL of H 2 O was added. A total of 100 µL hydroxylamine hydrochloride (10%) and 700 µL 1,10phenanthrolinehydrochloride (0.1%) were added to 200 µL of this solution. After a reaction time of 15 min, the absorbance of the formed ferroin complexes was measured by UV-Vis spectrometer (Cary 50, Varian, Palo Alto, CA, USA) at a wavelength of 510 nm, and the iron concentrations were calculated using an iron standard calibration curve (Iron (II,III) Oxid (Sigma Aldrich, Darmstadt, Germany) as standard in the range c(Fe) = 1.25 to 40 mM). MPS measurements of single nanoparticle samples were performed using a commercial magnetic particle spectrometer (MPS-3, Bruker, Ettlingen, Germany) operating at an amplitude B ex = 25 mT and a frequency f 0 = 25 kHz. MPS detects the non-linear dynamic magnetic response of MNP exposed to an alternating magnetic field from which their MPI performance can be assessed. Originally, MPS was developed to assess the performance of MNP tracer materials in MPI. However, here, we use MPS to quantitatively reveal changes in the dynamic magnetic behavior of MNP mediated by the direct environment of the MNP, e.g., as a consequence of surface modification by BSA-coating or physiological conditions as different saline concentrations. For MPS measurement, a fast reaction tube (Applied Biosystems ® , MicroAmp, Thermo Fisher Scientific, Schwerte, Germany) containing a sample volume of 30 µL was placed in the detection coil of the MPS system. The induced magnetization could be measured simultaneously by the coils. By Fourier transform of the detected time signal, the spectral components of an MPS measurement were obtained, showing distinctive amplitudes at odd multiples (harmonics) of the excitation frequency f 0 . We used two characteristic parameters of the MPS harmonic spectra, the amplitude of the third harmonic normalized to the iron amount of the sample, A 3 *, and the concentration-independent ratio between the 5th and 3rd harmonic, A 5 /A 3 . Both values are correlated to the MPI performance, with the general observation that the higher the A 3 * and A 5 /A 3 , the better the MPI images. The specific signal amplitude A 3 * indicates the sensitivity of the MNP to give a dynamic magnetization response at the chosen excitation frequency f 0 per unit amount of iron, and the ratio A 5 /A 3 is used to describe the shape of the harmonic spectrum to assess the resolution capacity. Two commercial MNP systems were considered as references with high MPS performance. For the MRI liver contrast agent Resovist (Meito Sanyo, Japan), we used the literature values A 3 * = 8.7 Am 2 /kg(Fe) and A 5 /A 3 = 38.4% [71] . Furthermore, carboxyl iron oxide MNP with 30 nm core diameter (SHP-30-10, Ocean NanoTech, US) measured by MPS at B ex 25 mT resulted in A 3 * = 32.8 Am 2 /kg(Fe) and A 5 /A 3 = 22.2%. To analyze the colloidal stability of MNP at different saline concentrations by MPS, 10 µL aliquots of as-synthesized, centrifuged, and BSA-coated MNP incubated with a final concentration of c (NaCl) = 0.05, 0.10, and 0.15 mol/L were taken after 2 h, 1 day, and 1 week. The MPS measurements were carried out at B ex = 25 mT and T = 37 • C. 3.4.2. NMR Relaxivities r 1 and r 2 MRI imaging properties were investigated by measuring longitudinal T 1 and transversal T 2 proton relaxation times for an MNP sample of 200 µL volume diluted to different iron concentrations c (Fe). The relaxation time measurements were carried out on a Minispec mq60 relaxometer (Bruker, Ettlingen, Germany) at T = 37 • C and a magnetic field of 1.5 T (60 MHz proton resoncane frequency). For T 1 , a 2-pulse inversion-recovery sequence with a fixed relaxation delay of at least 5 T 1 was used, T 2 was determined employing a Carr-Purcell-Meiboom-Gill sequence, which consists of a 90 • pulse followed by a series of 180 • pulses, ideally covering the full decay of the signal. From the graphs of the iron-concentration c(Fe)-dependent relaxation times R 1 = 1/T 1 and R 2 = 1/T 2 , the corresponding relaxivities r 1 and r 2 (in units of L·mmol −1 ·s −1 ) were determined: 1 For graphical presentation, the measured relaxation rates of pure water samples have been subtracted (R 1,H2O = 0.25952 s −1 and R 2,H2O = 0.29 s −1 ). Room temperature (T = 295 K) linear magnetic AC susceptibility (ACS) of MNP was measured with a commercial AC susceptometer (DynoMag, RISE Acreo, Gothenburg, Sweden). For the measurements, a sample volume of 200 µL MNP suspension was filled into a quartz glass cuvette, and the real χ (f ) and imaginary χ (f) magnetic susceptibility were acquired in the frequency range 1 Hz to 100 kHz at an excitation amplitude of 0 . 2 mT. The initial mass susceptibility χ 0 (in units m 3 /kg(Fe), normalized to the sample iron mass) was obtained by extrapolation of the real part susceptibility χ (f )| f → 0 . Surface modification was performed to optimize the stability and performance of continuously manufactured MNP for molecular imaging applications such as MPI and MRI in a physiological environment. Protein coating of electrostatically stabilized nanoparticles with BSA led to a significant improvement in dispersion stability in the presence of an increasing concentration of NaCl solution. No drop in signal amplitude and constant A 5 /A 3 values prove the good performance of the MNP as MPI contract agents. Additionally, r 1 and r 2 values are promising to apply MNP as MRI contrast agents. Since Resovist was withdrawn from the market, our MNP are promising candidates to further accelerate the research on MPI and MRI molecular imaging. Even after 40 years of MRI contrast agent developments for clinical use (the first MRI contrast agent, introduced in 1981, was ferric chloride), newer and safer MRI agents capable of specifically targeting organs, sites of inflammation, and tumors are still demanded. The presented micromixer technique to synthesize MNP-based contrast agents with tailored magnetic properties provides a major contribution to future developments. The same applies to MPI being under development for medical imaging of the cardiovascular system, for oncology or for stem cell tracking, where the structural, magnetic, and surface properties of the MNP are of utmost importance and need further optimization. With its excellent control of particle size, crystal growth, and scalability, the micromixer technique in combination with additional surface modification can also foster the further development of high-performing tracer materials for this promising imaging modality. Molecular and Cellular MR Imaging Molecular imaging in living subjects: Seeing fundamental biological processes in a new light Subsecond total-body imaging using ultrasensitive positron emission tomography Results of initial low-dose computed tomographic screening for lung cancer Quantitative SPECT Imaging: A Review and Recommendations by the Focus Committee of the Society of Nuclear Medicine Computer and Instrumentation Council. M.S Superparamagnetic iron oxide nanoparticles for in vivo molecular and cellular imaging Investigation of magnetic properties of various complexes prepared as contrast agents for MRI Contrast agents for MRI Recent advances in polymercoated iron oxide nanoparticles as magnetic resonance imaging contrast agents Cell internalization of anionic maghemite nanoparticles: Quantitative effect on magnetic resonance imaging Ferucarbotran (Resovist): A new clinically approved RES-specific contrast agent for contrast-enhanced MRI of the liver: Properties, clinical development, and applications Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application Immunological effects of iron oxide nanoparticles and iron-based complex drug formulations: Therapeutic benefits, toxicity, mechanistic insights, and translational considerations Improving cancer imaging with magnetic nanoparticles: Where are we now? Nanomedicine Dynamically Reversible Iron Oxide Nanoparticle Assemblies for Targeted Amplification of T1-Weighted Magnetic Resonance Imaging of Tumors Mussel-Inspired Multidentate Block Copolymer to Stabilize Ultrasmall Superparamagnetic Fe3O4 for Magnetic Resonance Imaging Contrast Enhancement and Excellent Colloidal Stability Multifunctional Theranostic Nanoparticles Based on Exceedingly Small Magnetic Iron Oxide Nanoparticles for T1-Weighted Magnetic Resonance Imaging and Chemotherapy Influence of Experimental Parameters of a Continuous Flow Process on the Properties of Very Small Iron Oxide Nanoparticles (VSION) Designed for T1-Weighted Magnetic Resonance Imaging (MRI) Tomographic imaging using the nonlinear response of magnetic particles Magnetic particle imaging in vascular medicine Magnetic Particle Imaging: A Novel In Vivo Imaging Platform for Cancer Detection Combined Preclinical Magnetic Particle Imaging and Magnetic Resonance Imaging: Initial Results in Mice. Rofo: Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin System Characterization of a Highly Integrated Preclinical Hybrid MPI-MRI Scanner Continuously manufactured single-core iron oxide nanoparticles for cancer theranostics as valuable contribution in translational research Effects of size distribution on hysteresis losses of magnetic nanoparticles for hyperthermia Superparamagnetic iron oxide nanoparticles for delivery of therapeutic agents: Opportunities and challenges Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition MPS and MRI efficacy of magnetosomes from wild-type and mutant bacterial strains Towards standardized purification of bacterial magnetic nanoparticles for future in vivo applications Characterization of magnetic nanoparticles from Magnetospirillum Gryphiswaldense as potential theranostics tools Micromixer Synthesis Platform for a Tuneable Production of Magnetic Single-Core Iron Oxide Nanoparticles Continuous synthesis of single core iron oxide nanoparticles for MPI tracer development Spherical magnetic nanoparticles fabricated by laser target evaporation Biocompatible Colloidal Suspensions Based on Magnetic Iron Oxide Nanoparticles: Synthesis, Characterization and Toxicological Profile Iron-based nanoparticles and their potential toxicity: Focus on oxidative stress and apoptosis Comprehensive cytotoxicity studies of superparamagnetic iron oxide nanoparticles Toxicity of iron oxide nanoparticles: Size and coating effects Amphiphilic starlike dextran wrapped superparamagnetic iron oxide nanoparticle clsuters as effective magnetic resonance imaging probes Preparation, characterization and MRI application of carboxymethyl dextran coated magnetic nanoparticles Characterization and MRI study of surfactant-coated superparamagnetic nanoparticles administered into the rat brain Evaluation of PEG-coated iron oxide nanoparticles as blood pool tracers for preclinical magnetic particle imaging Biocompatible Peptide-Coated Ultrasmall Superparamagnetic Iron Oxide Nanoparticles for In Vivo Contrast-Enhanced Magnetic Resonance Imaging The role of albumin in fluid and electrolyte balance Rapid confirmation and revision of the primary structure of bovine serum albumin by ESIMS and Frit-FAB LC/MS Response Rate Following Albumin-Bound Paclitaxel Plus Gemcitabine Plus Cisplatin Treatment Among Patients with Advanced Pancreatic Cancer: A Phase 1b/2 Pilot Clinical Trial Comparing Neoadjuvant Nab-paclitaxel vs Paclitaxel Both Followed by Anthracycline Regimens in Women with ERBB2/HER2-Negative Breast Cancer-The Evaluating Treatment with Neoadjuvant Abraxane (ETNA) Trial: A Randomized Phase 3 Clinical Trial Modifying plasmid-loaded HSA-nanoparticles with cell penetrating peptides-Cellular uptake and enhanced gene delivery Bio-Inspired Protein-Based Nanoformulations for Cancer Theranostics Enhanced stability of superparamagnetic iron oxide nanoparticles in biological media using a pH adjusted-BSA adsorption protocol Ultrasmall Superparamagnetic Iron Oxide Nanoparticle for T2-Weighted Magnetic Resonance Imaging T 1 -Weight Magnetic Resonance Imaging Performances of Iron Oxide Nanoparticles Modified with a Natural Protein Macromolecule and an Artificial Macromolecule BSA Immobilization on Amine-Functionalized Superparamagnetic Iron Oxide Nanoparticles Bovine Serum Albumin-Conjugated Ferrimagnetic Iron Oxide Nanoparticles to Enhance the Biocompatibility and Magnetic Hyperthermia Performance Surface Modification of Magnetic Iron Oxide Nanoparticles Surface Modification of Iron Oxide-Based Magnetic Nanoparticles for Cerebral Theranostics: Application and Prospection Rapid formation of plasma protein corona critically affects nanoparticle pathophysiology Gel electrophoresis of gold-DNA nanoconjugates Antibacterial and Anti-Inflammatory pH-Responsive Tannic Acid-Carboxylated Agarose Composite Hydrogels for Wound Healing Intracellular dynamics of superparamagnetic iron oxide nanoparticles for magnetic particle imaging Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths Coating thickness of magnetic iron oxide nanoparticles affects R2 relaxivity Systemic toxicity induced by aggregated layered double hydroxide nanoparticles Immediate Hypersensitivity to Polyethylene Glycols and Polysorbates: More Common than We Have Recognized Maintaining Safety with SARS-CoV-2 Vaccines Complement activation following first exposure to pegylated liposomal doxorubicin (Doxil ® ): Possible role in hypersensitivity reactions New possibilities of accurate particle characterisation by applying direct boundary models to analytical centrifugation Average protein density is a molecular-weight-dependent function A 1,10-Phenanthroline Method for the Determination of Iron in Powdered Milk Magnetic nanoparticles in different biological environments analyzed by magnetic particle spectroscopy Acknowledgments: Many thanks to Helen Onyema for proof reading of the manuscript. The authors declare no conflict of interest.