key: cord-0062792-0okqq1e9 authors: Zhao, Y.; Tian, Sh.; Yu, L.; Zhang, Zh.; Zhang, W. title: Analysis and Classification of Hepatitis Infections Using Raman Spectroscopy and Multiscale Convolutional Neural Networks date: 2021-05-06 journal: J Appl Spectrosc DOI: 10.1007/s10812-021-01192-6 sha: c67a0757b40dd7bafe0a33432c8408bc6f62f97e doc_id: 62792 cord_uid: 0okqq1e9 Hepatitis infections represent a major health concern worldwide. Numerous computer-aided approaches have been devised for the early detection of hepatitis. In this study, we propose a method for the analysis and classification of cases of hepatitis-B virus ( HBV), hepatitis-C virus (HCV), and healthy subjects using Raman spectroscopy and a multiscale convolutional neural network (MSCNN). In particular, serum samples of HBV-infected patients (435 cases), HCV-infected patients (374 cases), and healthy persons (499 cases) are analyzed via Raman spectroscopy. The differences between Raman peaks in the measured serum spectra indicate specific biomolecular differences among the three classes. The dimensionality of the spectral data is reduced through principal component analysis. Subsequently, features are extracted, and then feature normalization is applied. Next, the extracted features are used to train different classifiers, namely MSCNN, a single-scale convolutional neural network, and other traditional classifiers. Among these classifiers, the MSCNN model achieved the best outcomes with a precision of 98.89%, sensitivity of 97.44%, specificity of 94.54%, and accuracy of 94.92%. Overall, the results demonstrate that Raman spectral analysis and MSCNN can be effectively utilized for rapid screening of hepatitis B and C cases. and implement classifi cation and prediction tasks in large-scale and big-data problems [12] . Deep learning has especially been applied for solving complex chemical and biological problems in the fi elds of spectroscopy [13] [14] [15] [16] [17] , proteomics [18] [19] [20] , metabolomics [21, 22] , and genomics [23, 24] . In particular, convolutional neural networks (CNNs) represent one of the most prominent deep learning architectures. However, conventional single-scale convolution kernels in CNNs miss key details during the information encoding process. Inspired by the InceptionNet [25] architecture, multiscale convolution kernels are used in this study to extract rich, inconspicuous features from the input Raman spectra. This multiscale scheme promotes the encoding of more useful Raman spectral features. We proposed to use Raman spectroscopy in combination with a multiscale convolutional neural network (MSCNN) to differentiate between HBV, HCV, and healthy samples. Firstly, Raman spectral features are obtained for each sample. Then, principal component analysis (PCA) is applied to reduce the dimensionality of spectral features. Subsequently, mean normalization is performed on the spectral features. Finally, the spectral features are used to train and test a MSCNN architecture. An experiment is designed to compare the performance of deep learning and conventional classifi ers. The deep learning classifi ers include a single-scale CNN, MSCNN, and MSCNN with a long short-term memory (LSTM). The conventional classifi ers include the naive Bayes classifi er, k-nearest neighbor (KNN) classifi er, logistic regression, random forests, decision trees, support vector machines (SVMs), and gradient boosting decision trees (GBDTs). Materials and Methods. Serum sample collection. For the experimental evaluation of the proposed method, we collected 435, 374, and 499 serum samples of hepatitis-B patients, hepatitis-C patients, and healthy subjects, respectively. The diagnosis and sample collection were done at the First Affi liated Hospital of Xinjiang Medical University. The serum samples of the HCV-infected patients passed the reverse transcriptase polymerase chain reaction (RT-PCR) test. The RT-PCR method was used to quantitatively detect the HCV RNA. For each HBV-and HCV-infected patient, we collected 5 mL of fresh blood after 8 h of fasting. After full coagulation of the blood sample, components such as fi brinogen and blood cells were removed by a high-speed centrifuge at a speed of 3000 rpm. Then, a serum volume of 500 μL was collected in an Eppendorf tube and stored at -80 o C. Before the examination, the specimen under test was placed in an environment of 22 o C for 30 min. After suffi cient dissolution, 30 μL of the serum sample was captured in a capillary glass tube for spectral analysis. The age and gender information of the study sample is shown in Table 1 . Raman spectroscopy. The source laser beam was focused on the surface of a droplet by a 50× microscope objective (numerical aperture = 0.5) with a spectral resolution of 5 cm -1 and a recording time of 1.0 s (LabRAM HR Evolution Raman Spectrometer, HORIBA Scientifi c Ltd.). The spectral data resolution and Raman shift were measured three times and averaged, and the corresponding average values were 5 and 300-3000 cm -1 , respectively. Preprocessing and analysis of spectral data. Since the raw Raman spectra obtained from the serum sam ples contained signifi cant fl uorescence background and noise, spectral preprocessing was necessary [26] [27] [28] . The preprocessing steps were as follows: the fl uorescent background was removed; spectral smoothing was applied; PCA was used to reduce the feature dimensionality. For background subtraction, the Vancouver Raman algorithm based on a fi fth-order polynomial was used to fi t all the autofl uorescence backgrounds of serum. The Savitzky-Golay fi lter was used to smooth the spectra of all the samples, and the fi fth-order polynomial was subtracted to correct the baseline [29] . Finally, comparative experiments were conducted to select the appropriate samples. Evaluation criteria. For the experiments, we divided the collected data into training and test sets with sizes in the ratio of 4:1. For performance evaluation, a confusion matrix was used to numerically quantify the misclassifi cation among the pairs of classes [30] . Specifi cally, this matrix described the confusion between the real and output classes, where the nondiagonal element in the ith row and jth column indicated the number of samples in the ith class that were wrongly recognized by the classifi er as samples of the jth class. The number of the correctly classifi ed samples of the ith class was stored as the ith diagonal element in the confusion matrix [31] . The following performance measures can be derived from the confusion matrix. Specifi city: Ratio of the truly negative samples that have been correctly classifi ed. F1-Score: This a measure of the classifi cation accuracy based on a combination of the precision and recall. The value of this measure ranges from 0 (worst performance) to 1 (best performance). Advanced Spectral Data Processing. PCA-based dimensionality reduction. PCA is a dimensionality reduction method based on linear transformations. Essentially, the input features are projected to several coordinates for maximizing the feature variance by coordinate rotation and obtaining a new data representation that is more aligned with principal variations. Dimensionality reduction is achieved by exploiting multicollinearity [32] . The PCA-based dimensionality reduction algorithm can be outlined as follows: Input: A Raman spectral sample set Steps: 1) Subtract the data mean: For the Raman intensity corresponding to each Raman shift, subtract the mean of the jth feature from each ith sample, The mean values of the features can be combined into a mean vector μ = (μ 1 , μ 2 , ..., μ d ), 2) Calculate the covariance matrix of the Raman spectral data 3) Perform an eigenvalue decomposition of the covariance matrix X T X Σ = . Use the eigenvectors u 1 , u 2 ... corresponding to eigenvalues λ 1 > λ 2 >... to form the transformation matrix U. Output: Mean Normalization. Normalization or scaling of features [33] ensures the same range of values for each feature. Normalization can be formulated as follows: value max This operation leads to numerical stability and helps in reaching the optimal solution. Indeed, normalization causes the gradient to always move in the direction of the minimum objective value. This leads to the acceleration of convergence and faster attainment of the global minimum [34] . Model Construction. Multiscale convolution neural network. MSCNNs were used as the learning framework in this work. An MSCNN consists of three parts: multiscale feature extraction layers, multiscale feature fusion layers, and the dimensionality reduction layers. The architecture of MSCNN is shown in Fig. 1 . Multiscale feature extraction layers. Multiscale feature extraction layers extract data characteristics from multiple scales. This layer is mainly composed of parallel convolution kernels of multiple scales. The characteristics of the convolution kernels at different scales are different. In this paper, we apply this feature extraction scheme with fi ve scales or sizes of convolution kernels. The fi rst multiscale feature extraction layer has fi ve kernel scales of 2*1, 3*1, 4*1, 5*1, and 10*1. The second multiscale feature extraction layer also has fi ve kernel scales of 1*1, 3*1, 5*1, 7*1, and 9*1. There are various methods for extracting feature scales. Too few feature scales can lead to underfi tting, while too many feature scales can cause overfi tting. Dropout and batch normalization modules are added after each convolutional layer. The dropout module can prevent overfi tting. Batch normalization signifi cantly speeds up the training of the deep learning model ( ) Let the input of each multiscale feature extraction layer be x, where the model contains m convolutional layers, and the sizes of convolution kernels between the layers are different. Then, the ith convolutional layer of the fi rst multiscale feature extraction module can be modeled as ( ) where x is the ReLU input. Multiscale feature fusion layers. A multiscale feature fusion layer fuses multiple features after multiscale feature extraction [35] . The mathematical expression for the output of such layer is ( ) where x represents the input of the multiscale feature extraction layer, f 1 (x) represents the output of the fi rst multiscale feature fusion layer, and the parameters 1 i W and 1 i B represent the weight and offset in the dimen sionality reduction layer, respectively. The operator δ1 i represents the operation of the ReLU nonlinear activation unit. Dimensionality reduction layer. The dimensionality reduction layer is composed of a convolution layer with a kernel size of 1*1. The number of convolution kernels in the convolutional layer is less than that of the channels in the multifeature fusion layer. The 1*1 kernel size can maintain all the feature information of the multifeature fusion layer. Due to the single-channel, the multiscale feature map obtained by the fi nal convolution is also reduced. This leads to a reduced dimensionality. The output of the dimensionality reduction layer of the fi rst multiscale feature fusion module is expressed as follows: where x represents the input of the multiscale feature extraction layer, and f 1 (x) represents the output of the fi rst multiscale feature fusion layer. The parameters 1 1 m W + and 1 1 m B + represent the weight and offset in the dimensionality reduction layer, respectively, and δ represents the ReLU nonlinear activation unit of the dimensionality reduction layer. The outputs of the multiscale feature fusion modules of layers other than the fi rst layer (l > 2) are expressed as follows: LSTM architecture is often used in natural language processing, especially in sentiment analysis. Further, it has been used in classifi cation models that fuse multiple features [36] as well as in analog classifi cation problems. However, the results show that the accuracy of LSTM is 4.05% less than that of MSCNN. LSTM increases the training time, and the relative advantages of MSCNN are obvious. Results and Discussion. Raman spectral analysis. As a type of fi ngerprint, the Raman spectra of serum can be used to detect changes in biological molecules, such as proteins, nucleic acids, and lipids, of different organisms and interpret the physiological fl uctuations of the body to diagnose diseases. As shown in Fig. 2 , after the baseline correction, the values of Raman spectral intensity for HBV-infected patients are generally higher than those for healthy subjects, while the values for HCV-infected patients are essentially lower than those for healthy subjects. The Raman shift is 1154.58 cm -1 . Further, the peak intensities of the three spectra are 2910, 2731, and 2213 a.u. for the HBV, healthy, and HCV subjects, respectively. Through baseline correction, the differences between the principal components (PCs) of the three spectral classes can be better explained. The three Raman spectra are quite similar in shape. However, there are intensity differences at Raman shifts of 509, 875, 1018, 1154, 1155, 1444, 1595, 2660, and 2850 cm -1 . Table 2 lists the Raman shifts and the associated causes for the samples. The Raman peaks at 509 and 2660 cm -1 correspond to cysteine and methionine, respectively [44, 45] . Since the liver is crucial for amino acid metabolism, HBV causing liver damage also leads to disorders in the amino acid metabolism, thereby affecting the amino acid profi le of serum [46] . The Raman peak at 875 cm -1 corresponds to the antisymmetric stretching vibration of the choline group N+ (CH 3 ) 3 , which has the characteristics of phospholipids, phosphatidylcholine, and sphingomyelin [47] . The peak at 1444 cm -1 in the serum spectrum is assigned to CH 2 wagging of cholesterol and lipids, which exhibits a higher intensity in the HBV infection group. Bremer et al. found that the HBV infection depends on the presence of cholesterol in the viral envelope and is essential for the entry process of the HBV [48] . Li et al. demonstrated that the HBV aggravates the accumulation of hepatic cholesterol, which affects the content of serum cholesterol [49] . The main characteristic peaks in the Raman spectrum that correspond to HBV are located at 1018, 1154, 1595, and 2850 cm -1 . Among them, the peak at 1018 cm -1 is related to a ribose (DNA), while the one at 1154 cm -1 corresponds to the deformation of carbohydrates. The peak at 1595 cm -1 is relatively strong, which may be attributed to an early liver injury that occurred due to a viral infection, for which benzoquinone is an important biomarker. On the other hand, the Raman peak at 2850 cm -1 corresponds to lipids and fatty acids. The differences in the strength of these peaks may be due to the imbalance of liver metabolism; thus, they can be used as a characteristic peak in the diagnosis of HBV [50] . The Raman peak at 1155 cm -1 is a spectral signature for the CO group of ribose, which is already reported as the most reliable marker for the HCV detection in serum [51] . Therefore, our results validate the previous reports on this Raman band for detecting HCV infection. The presence of the positive difference bands in the range of 1200-1400 cm -1 indicates that the base stacking of A-RNA sequences is signifi cantly perturbed under interaction with HCVc-120 protein [52] . Furthermore, the 1400-1600 cm -1 region in the Raman spectrum of HBV and HCV is due to the presence of C-120 protein in human blood serum, which exhibits a strong broad amide-I bond centered near 1500-1600 cm -1 . Compared to the normal samples, the protein and lipid structures of HBV and HCV specimens are different. Spectral changes are observed in the protein bands, amide I (1560-1590 cm -1 ), amide 3, and N(C-C) stretching (possibly in amino acids, 960-980 cm -1 ) [40, 53] . In addition, potential variations in the polysaccharide structure are noticed in the range of 860-870 cm -1 . The analysis of band intensity in the ranges of 1560-1570, 1400-1460, and 1000-1030 cm -1 allows for the complete separation of HBV-and HCV-infected serums from normal serums. For HCV cases, the viral structure and nonstructural proteins are created by the cleavage of the polyprotein precursors of the host cell signal peptidase and the viral proteases [54] . The structural core protein is derived from the amino terminus of the polyprotein and may form virion nucleocapsid because they are highly basic and similar in many biological properties. The nucleotide and predicted amino acid sequences of the core protein gene are highly conserved in different HCV isolates. Earlier investigations have shown that truncated proteins covering the core protein (HCVc-120) are assembled into nucleocapsid-like particles without the presence of nucleic acids with similar morphological and size distributions in the serum of hepatocytes from HCV-infected patients. This explains the abnormal levels of liver enzymes, such as alanine aminotransferase (ALT), and the active division of viruses (HBeAg-positive or high-level HBV DNA) in the human blood and liver biopsies, which show moderate disease activities in hepatitis-B cases. The C virus confi rms the presence of positive HCV RNA. Table 3 shows the performance of this algorithm for different numbers of PCs. It is evident that the specifi city reaches 99.98% when the PC count is 200, and the highest precision of 99.89% is achieved when the PC count is 400. Further, the highest sensitivity and accuracy of 94.54 and 94.92%, respectively, are attained when the PC count is 512, i.e., the best performance is achieved at this PC count. Hence, we set the number of PCs as 512 in subsequent experiments (Table 4) . Mean normalization. To prove the effectiveness of mean normalization, we performed two sets of experiments. As shown in Table 3 , the utilization of mean normalization increases the specifi city by 0.47%, precision by 5.83%, sensitivity by 4.00%, and accuracy by 4.37%. Comparative experiments. To verify the effi cacy of the proposed network, we conducted three comparative experiments using: different layers in our network; commonly used algorithms in deep learning; commonly used algorithms in machine learning. Feature scales can be extracted through various methods. Too few or too many feature scales can easily lead to underfi tting or overfi tting, respectively. To compare the stability and goodness of fi t for different classifi ers, we performed comparative experiments on multiscale fusion of different layers. Here, all the compared algorithms were implemented in the PyCharm environment. The experimental results in Table 5 show that with two extraction and fusion layers, the specifi city, precision, sensitivity, and accuracy are 97.44, 98.89, 94.54, and 94.92%, respectively. With one extraction and fusion layer, the , characteristic for phospholipids [37] Stretching C-O ribose [38] 1154 Deformational mode of carbohydrates [39] 1155 Spectral signature for the CO group of ribose [40, 41] 1595 2850 860-870 960-980 1000-1030 cm -1 1400-1460 1400-1600 1500-1600 Benzoquinone [42] Lipids, fatty acids [42] Possible changes in polysaccharide structure are observed in this region [43] N(C-C) stretching (probably in amino acids) [43] This region allowed for a complete separation between HBV-and HCV-infected and normal blood serum spectra [43] This region allowed for a complete separation between HBV-and HCV-infected and normal blood serum spectra [43] C-120 protein in human blood serum [43] Amide-I bond [43] experimental results show underfi tting, and the accuracy is reduced by 2.43% compared to the two-layer scheme. With three extraction and fusion layers, the experimental results show overfi tting, and the accuracy is reduced by 3.22% compared to the two-layer scheme. Compared to the one-layer and three-layer schemes, the extraction and fusion layers provide better performance in a two-layer scheme. Overall, these results indicate that the two-layer multiscale fusion scheme exhibits better stability than the one-layer multiscale fusion scheme and has better fi t than the three-layer multiscale fusion scheme. For comparison of deep learning architectures, we conducted three sets of experiments . As shown in Table 6 , we also tried CNNs, whose fi tness is inferior to that of MSCNN. In this experiment, although the specifi city of CNN reaches 99.18%, its accuracy is only 68.56%. Indeed, single-convolution kernels tend to remove more spectral information, while multiscale deep schemes improve the accuracy of spectral classifi cation. Features of the input spectral intensity are extracted using convolution kernels of different scales to enhance the robustness of algorithm to interfering factors. To compare MSCNN with different machine learning methods, we conducted eight sets of experiments. Here, we also used conventional classifi ers including those of naive Bayes, KNN, logistic regression, random forests, decision trees, SVMs, GBDT along with MSCNN for the three-class hepatitis classifi cation problem. The experimental results indicate that conventional classifi ers are not adequate for this classifi cation problem, but few of these classifi ers still have some advantages. The experimental results are shown in Table 7 . Here, for the naive Bayes classifi er, it is assumed that the input features are independent of each other. However, this assumption is not practically true because the number of spectral features is relatively large and therefore the correlation between these features is large. Consequently, for the naive Bayes classifi er, the accuracy is quite low, and the specifi city is 7.97% lower than that of MSCNN. Generally, the KNN classifi er does not perform well for multidimensional data including Raman spectral data. High dimensionality of data leads to the 'curse of dimensionality,' and it increases the distance between two apparently similar spectral features. Consequently, the sensitivity of KNN is much higher than that of the naïve Bayes classifi er, but it is still far lower than that of MSCNN. Logistic regression cannot handle a large number of multiclass spectral features effi ciently. While the sensitivity for this classifi er is relatively high, it is still lower than that of MSCNN by 8.05%. The decision tree classifi er ignores the correlation between the Raman spectral features, which leads to low performance metrics and high overfi tting. Overfi tting problems can be reduced using random forests, which are equivalent to multiple decision trees whose predictions are pooled to obtain an ensemble prediction. For the random forest classifi er, the specifi city and precision are perfectly 100%, but the sensitivity is extremely low. While random forests suffer from a low sensitivity, the GBDT classifi er has a relatively high sensitivity, and its accuracy (82.45%) comes second after MSCNN. However, due to the dependence between the weak classifi ers of GBDT, it is diffi cult to train these classifi ers in parallel. SVM algorithm was originally designed for binary classifi cation problems. For multiple classes, it is necessary to construct a suitable multi-class classifi er. We classify the hepatitis-B and non-hepatitis-B samples, and then classify the nonhepatitis-C and hepatitis-C samples into two categories. This disturbs the sample balance, and the results are generally inferior for the rare category, namely, the hepatitis category. In general, traditional machine learning algorithms are not very effective for the three-category classifi cation problem. Model evaluation. The classifi cation results of MSCNN are specifi city 0.974 ± 0.011, precision 0.989 ± 0.015, sensitivity 0.945 ± 0.008, accuracy 0.949 ± 0.010. It is clear that the MSCNN model outperforms the other models in terms of accuracy and sensitivity. Although the specifi city of CNN reaches 99.18%, a CNN with a single convolution kernel misses more details during information encoding. While random forests show 100% specifi city and precision, their accuracy and sensitivity are quite inferior to those of MSCNN. For a better experimental evaluation, GPU acceleration was used with an NVIDIA 1060 graphics card. In this experiment, we chose a setup where dimensionality reduction was fi rstly applied with 512 PCs. Then, the features were normalized by the mean value, and fi nally the MSCNN architecture was used for classifi cation. Aver aging the performance over ten runs results in an accuracy of 98.89%, sensitivity of 97.44%, specifi city of 94.54%, and accuracy of 94.92%. The confusion matrix shows the classifi cation outputs for one run. We demonstrated the effectiveness of using deep learning MSCNN model and serum Raman spectroscopy to screen the HBV-infected and HCV-infected patients and differentiate them from healthy subjects. The baseline correction of spectral data revealed interesting differences between the three classes in terms of biomolecular structure and the relative contents of lipids, cholesterol, proteins, cysteine, etc. The classifi cation performance analysis of MSCNN revealed that the pull Mann's spectrum of serum can be effi ciently used to diagnose potential HBV-infected and HCV-infected cases. Owing to the rapid advancement and utilization of Raman spectroscopy, our work is expected to provide accurate and rapid guidance for the treatment of HBV-infected and HCV-infected patients in the near future. Liver Disease: A Clinical Casebook Proc. IEEE Conf. Computer Vision and Pattern Recognition Workshops The Nature of Statistical Learning Theory Whether there is a COI or not, such a separate COI page should be established immediately before the References stating the authors take responsibility for any confl ict of interest.