key: cord-0054421-yyfagegi authors: Sen, Rupanwita; Mallepally, Abhinandan Reddy; Sakrikar, Gayatri; Marathe, Nandan; Rathod, Tushar title: Comparison of TruView and King Vision video laryngoscopes in subaxial cervical spine injury: A randomized controlled trial date: 2020-11-06 journal: Surg Neurol Int DOI: 10.25259/sni_638_2020 sha: 8d7aa5daa8eb4f6a5a90e039143b9976eb5fbd56 doc_id: 54421 cord_uid: yyfagegi BACKGROUND: Airway management with cervical spine immobilization poses a particular challenge for intubation in the absence of neck extension and risks neurological damage in cases of unstable cervical spine injuries. Here, with manual inline stabilization (MILS) in patients with cervical spine injuries, we compared the safety/efficacy of intubation utilizing the TruView versus King Vision video laryngoscopes. METHODS: This prospective, single-blind, comparative study was conducted over a 3-year period. The study population included 60 American Society of Anesthesiologists (ASA) Grade I-III patients, aged 18–65 years, who underwent subaxial cervical spine surgery utilizing two intubation techniques; TruView (TV) versus King Vision (KV). For both groups, relative intubation difficulty scores (IDS), total duration of intubation, hemodynamic changes, and other complications (e.g., soft-tissue injury and neurological deterioration) were recorded. RESULTS: With MILS, patients in the KV group had statistically significant lower IDS (0.70 ± 1.02) and significantly shorter duration of intubation as compared to the TV group (1.67 ± 1.27) with MILS (P = 0.0010); notably, the glottic exposure was similar in both groups. The complication rate (e.g., soft-tissue injury) was lower for the KV group, but this was not statistically significant. Interestingly, no patient from either group exhibited increased neurological deterioration attributable to the method of intubation. CONCLUSION: King Vision has several advantages over TruView for intubating patients who have sustained cervical spine trauma. Nevertheless, both laryngoscopes afford comparable glottic views and safety profiles with similar alterations in hemodynamics. Manual in-line axial stabilization (MILS) is used for airway management where other stabilization methods are inappropriate. [7] e TruView (TV) EV02 (TruView PCD TM 4150, Truphatek International Ltd., Netanya, Israel) is an optical laryngoscope that gives 42 ○ deflection view through a 15 mm eyepiece; it provides wider angle of vision even in neutral position. e King Vision [10] (KV) video laryngoscope (KVL03C, King Systems Corporation, Germany) ensures optimum quality images of the vocal cords, has two types of blades, and can accommodate an endotracheal tube between 6.0 and 8.5 mm ID [ Figure 1 ]. is pilot study compared the safety/efficacy of tracheal intubation utilizing the TV and KV when combined with MILS in patients with subaxial cervical spine trauma [ Figures 2 and 3 ]. is was an IRB approved, randomized prospective, singleblind, comparative study conducted over a 3-year period (January 2017-December 2019) at tertiary care spinal injuries center [ Figure 4 ]. All patients were analyzed by the same anesthetist who is also the lead author of this paper to ensure no bias. Demographic variables, airway assessment, and ASA grading were noted preoperatively. e study population included 60 patients of ASA I-III, aged 18-65 years undergoing subaxial cervical spine surgery under general anesthesia. [ Table 1 ]. Routine induction was performed in both population groups. MILS was applied to hold the mastoid process and side of the neck in position preventing any movement (flexion, extension, or rotation) of the neck. After mask ventilation for 2 min, laryngoscopy and orotracheal intubation were performed by an experienced anesthetist (at least 5 years) utilizing the TV or KV instruments. All intubations were carried out with size 3 blade for both the laryngoscopes. e total duration of intubation was visually confirmed by the anesthetist, and successful tube placement was confirmed utilizing routine modalities (e.g., capnography/end-tidal CO2). Complications during intubation including soft-tissue injuries were recorded. e sample size was measured with the pooled standard deviation of IDS from the past studies as 2.75 and two-sample t-tests were applied using the formula (μ1-μ2)/SD = 0.88. Using the following cutoff values of α as 0.05 and ß as 0.20 (or 80% power), a minimum required sample of 30 in each group was estimated. Quantitative variables (e.g., airway examination, IDS, number of attempts, and complications) were compared using Mann-Whitney test and Chi-square test. Hemodynamic alterations were compared using unpaired and paired t-tests. All results were analyzed using SPSS software version 23.0. Our study included 60 subjects; 30 in either group, who had sustained subaxial cervical spine injuries resulting Patients with ASA grade >3 Difficult airway because of trauma to airway or blood in airway or reduced mouth opening <3 cm Mallampati class (MPC) grade > III or congenital anomalies Patients with buck teeth, edentulous jaw, loose teeth Patients who required emergency intubation and rapid sequence intubation Patients with injury to supra-axial cervical spine in comparable preoperative neurological deficits [Tables 2 and 3 ]. Cases were classified into five age groups at 10-year intervals [ Table 4 ]. ey exhibited comparable variables regarding sex distribution, ASA presenting grades, and upper lip bite texts. With MILS, patients in the KV group had statistically significant lower IDS (0.70 ± 1.02) and significantly shorter duration of intubation as compared to the TV group (1.67 ± 1.27) with MILS (p = 0.0010) [ Table 5 ]. Notably, the glottic exposure was similar in both groups. e complication rate (e.g., soft-tissue injury) was lower for the KV group, but this was not statistically significant. Interestingly, no patient from either group exhibited increased neurological deterioration attributable to the method of intubation. e initial mean HR 1 min before intubation was higher in the KV group versus the TV group [ Table 6 ]. e differences regarding increases in MAP with laryngoscopy and intubation were not statistically significant at each measured interval for the two groups [ Table 7 ]. Managing airway with MILS is very difficult task for an anesthesiologist in patients with cervical spine injuries during resuscitation, administration of general anesthesia, and respiratory support. e TV laryngoscope and KV video laryngoscope are two indirect laryngoscopes each with an advanced optical technology. Bhardwaj et al. [2] found less neck movement occurring during laryngoscopy utilizing the TV versus Macintosh laryngoscope. El Tahan et al. [5] concluded that laryngoscopy with KV resulted in significantly less C0-C1 and C3-C4 segments motion with reduced cumulative upper cervical spine motion from C0 to C4. Prior studies done by Ali et al. [1] and Bharti et al., [3] respectively, have shown that KV and TV significantly improve laryngoscopic view as compared to Macintosh and McCoy in cervical spine immobilization. We additionally found that KV gives better IDS versus TV EVO2 (P = 0.0001). We found that the average intubation time was significantly less with the KV versus TV. e blade of the KV is designed in such a way that it coincides with the anatomical curvature of the oropharynx making it easier to insert with MILS. However, Priyanka et al. [6] had contrary findings; the KV took significantly more time than the TV for intubation. e more anatomically fitting design of the KV laryngoscope allowed lessor vertical force to achieve glottic alignment as compared to the TV, which resulted in lesser dental and softtissue injury versus TV. Further, the differences of rise in heart rate as well as MAP between the two groups were not statistically significant. Although both the laryngoscopes provided good glottic view, the KV was slightly better (e.g., ease of insertion with MILS, shorter intubation time, less soft-tissue injury, and reduced hemodynamic changes). e KV further has a provision of disposable blade which removes the concerns of contagious infections. [4] Finally, there were no significant changes in neurological status between the two groups utilizing KV versus TV, thus highlighting the safety of the procedure. King Vision has several advantages over TruView for intubating patients who have sustained cervical spine trauma. Nevertheless, both laryngoscopes afford comparable glottic views and safety profiles with similar alterations in hemodynamics. Institutional Review Board (IRB) permission obtained for the study. Publication of this article was made possible by the James I. and Carolyn R. Ausman Educational Foundation. ere are no conflicts of interest. A comparative evaluation of king vision video laryngoscope (channelled blade), McCoy, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine Assessment of cervical spine movement during laryngoscopy with Macintosh and truview laryngoscopes A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine COVID-19: Current knowledge and best practices for orthopaedic surgeons Does king vision™ videolaryngoscope reduce cervical spine motion during endotracheal intubation? A crossover study Comparison of king vision and truview laryngoscope for postextubation visualization of vocal cord mobility in patients undergoing thyroid and major neck surgeries: A randomized clinical trial Incidence and outcome analysis of vertebral artery injury in posttraumatic cervical spine