key: cord-0049798-xyeou3cd authors: nan title: Selected Abstracts from the September Issues of the Journal of Vascular Surgery and the Journal of Vascular Surgery: Venous and Lymphatic Disorders date: 2020-09-10 journal: Eur J Vasc Endovasc Surg DOI: 10.1016/s1078-5884(20)30759-0 sha: f3f11da4e4abd3f6aaff2293e3e22746c837f74c doc_id: 49798 cord_uid: xyeou3cd nan Off-the-shelf multibranched endograft for total endovascular repair of the aortic arch Côme Bosse, MD, Tilo Kölbel, MD, PhD, Justine Mougin, MD, Jarin Kratzberg, PhD, Dominique Fabre, MD, PhD and Stéphan Haulon, MD, PhD Objective: The goal of this study was to select branched endograft designs that could fit most aortic arch anatomies. Such off-the-shelf endografts, once available, would be an endovascular therapeutic option to consider in the acute setting and would shorten the design and manufacturing process. Methods: We retrospectively analyzed the endograft plans of all custom-made aortic arch branched endografts implanted between 2013 and early 2018 provided by the Cook Planning Center (EMEA Planning Services; Cook Medical, London, United Kingdom). Available data points of the endograft plans include proximal, intermediate, and distal endograft diameters; number of sealing stents; total length of the endograft; and number of branches. Results: There were 286 two-branch endografts analyzed. We divided the endografts in three groups according to their proximal diameters: 34 mm, 36 mm, and 38 mm (group 1); 40 mm and 42 mm (group 2); and 44 mm and 46 mm (group 3). In group 1, 63% of the endografts had one proximal sealing stent, whereas in group 3, 63% had two proximal sealing stents. The distal diameters of the endografts ranged from 26 mm to 46 mm. The mean length was 236 mm (186-256 mm). A shorter standardized length of 211 mm was selected to anticipate distal extensions. According to our analysis, most group 1 patients could have been treated with a 38-mm proximal diameter and 30mm distal diameter endograft with one sealing stent; most group 2 patients, with a 42-mm proximal diameter and 32mm distal diameter endograft with both one and two proximal sealing stents; and most group 3 patients, with a 46-mm proximal diameter and 36-mm distal diameter endograft, also with both one and two proximal sealing stents. Conclusions: Five standardized off-the-shelf endografts can cover a majority of aortic arch anatomies and offer an option for acute endovascular treatment of aortic arch disease. Vascular Quality Initiative assessment of compliance with Society for Vascular Surgery clinical practice guidelines on the care of patients with abdominal aortic aneurysm Jens Eldrup-Jorgensen, MD, Larry W. Kraiss, MD, Elliot L. Chaikof, MD, PhD, Dan Neal, MS and Thomas L. Forbes, MD Objective: Professional societies publish clinical practice guidelines to provide evidence-based recommendations to improve care and to reduce practice variation. However, the degree of compliance with the guidelines and its impact on outcomes have not been well defined. This study used the Vascular Quality Initiative (VQI) abdominal aortic aneurysm (AAA) registries to determine current compliance with and impact of recent Society for Vascular Surgery (SVS) AAA guidelines. Methods: Recommendations from the SVS AAA guidelines were reviewed and assessed as to whether they could be evaluated with current VQI data sets. The degree of compliance with these individual recommendations was calculated by center and correlated with clinical outcomes. Data were analyzed by univariate analysis and mixed effects multivariable logistic regression. Statistical significance was measured at P < .05. Results: Of the 111 SVS recommendations, 10 could be evaluated using VQI registries. The mean center-specific compliance rate ranged from 40% (smoking cessation 2 weeks before open AAA [OAAA] repair) to 99% (preservation of flow to one internal iliac artery during endovascular aneurysm repair [EVAR] ). Some recommendations were associated with improved outcomes (eg, cell salvage for OAAA repair and antibiotic prophylaxis), whereas others were not (eg, EVAR at a center with >10 cases per year or door-to-intervention time <90 minutes for ruptured AAA). With multivariable analysis, compliance with preservation of flow to the internal iliac artery decreased major adverse cardiac events in EVAR and marginally decreased in-hospital and 1-year mortality in OAAA repair. Antibiotic administration decreased surgical site infection, major adverse cardiac events, and in-hospital mortality and marginally decreased respiratory complications and 1-year mortality in EVAR. Cell salvage for OAAA repair decreased 1-year mortality. Tobacco cessation before EVAR or OAAA repair decreased respiratory complications and 1-year mortality. Conclusions: The VQI registry is a valuable tool that can be used to measure compliance with SVS AAA guidelines. Compliance with recommendations was associated with improved outcomes and should be encouraged for providers. Participation in the VQI registry provides an objective assessment of performance and compliance with guidelines. VQI provider and center reports may be used as a focus for quality improvement efforts. Objective: Failure of infrarenal endovascular aneurysm repair (EVAR) due to loss of proximal seal is increasingly common. Open surgical conversion can be challenging and has been associated with significant morbidity and mortality. The aim of this study was to evaluate the use of fenestrated-branched EVAR (F/BEVAR) for the treatment of patients with prior EVAR failure. Methods: Consecutive patients enrolled as part of the Aortic Research Consortium in six prospective, nonrandomized, physician-sponsored investigational device exemption studies evaluating F/BEVAR between 2012 and 2018 were included in this study. The cohort was stratified according to whether the F/BEVAR procedure was performed after EVAR failure. Demographics, operative details, perioperative complications, and length of stay were compared between groups. Postprocedural survival, type I or type III endoleak, target artery patency, target artery instability, and reintervention rates were calculated using Kaplan-Meier method and compared between groups. Results: A total of 893 patients underwent F/BEVAR; 161 (18%) were treated after failed EVAR and 732 (82%) were treated without prior EVAR. Patients with failed EVAR were more often men (84% vs 66%; P <.01) with larger aneurysms (6.9 cm vs 6.4 cm; P < .01). There were no differences in aneurysm extent (P = .20) between groups; for the entire cohort, there were 19% juxtarenal, 9.2% suprarenal, and 72% thoracoabdominal aneurysms. The average number of targeted arteries per patient was 3.6 in both groups. The procedural technical success (99% vs 97%; P = .15) did not differ between groups, but radiation dose (4750 vs 2920 mGy; P = .02), dose-area product (154,572 vs 82,842 mGy$cm 2 ; P < .01), and operative time (5.2 vs 4.6 hours; P < .01) were significantly higher in the failed EVAR group. Median intensive care unit length of stay (2.9 days) and total length of stay (6.3 days) did not differ between groups.The 30-day mortality rate (failed EVAR, 2.5%; no EVAR, 1.1%; P = .25) and 30-day major adverse event rates did not differ between groups. Kaplan-Meier estimates of freedom from type I or type III endoleak (91.9% vs 92.5%; P = .65), target artery patency (97.3% vs 97.0%; P = .91), freedom from target artery instability (86.3% vs 88.8%; P = .53), and freedom from reintervention at 1 year (84.7% vs 88.7%; P = .10) did not differ between the failed EVAR and no EVAR groups, respectively. One-year survival was decreased in the failed EVAR group (86.3% vs 91.9%; P = .02), but this effect did not persist on multivariable analysis (hazard ratio, 1.52; 95% confidence interval, 0.88-2.62; P = .14). Conclusions: In this multicenter study, F/BEVAR was safe and effective in patients with prior failed EVAR, with nearly identical outcomes to those of patients without prior EVAR. However, differences in procedural metrics indicate higher level of technical challenge in performing F/BEVAR in patients with prior failed EVAR. Paclitaxel-coated peripheral artery devices are not associated with increased mortality Objective: Long-term safety concerns have been raised that the use of paclitaxel-coated balloons and stents is linked to excess mortality. Our objective was to compare outcomes in patients treated with paclitaxel vs uncoated devices and to analyze long-term mortality. Methods: We conducted a retrospective single-institution review of 1170 consecutive patients who underwent femoropopliteal percutaneous revascularization by angioplasty, atherectomy, stent placement, or combination between 2011 and 2018. The primary outcome measure was allcause mortality. Groups were divided into patients who received paclitaxel (n = 652) and those who did not (n = 518). Categorical variables were assessed using c 2 analysis and continuous variables with the Wilcoxon signed rank test. A multivariable analysis was performed using multivariable logistic regression models. Mortality was compared using Kaplan-Meier survival analysis. Results: Demographics, risk factors, and Rutherford class were similar between the groups, except that the paclitaxel group was more likely to have diabetes (60.9% vs 55.0%; P = .04), was less likely to be on dialysis (10.7% vs 14.9%; P = .04), and had lower average creatinine concentration (1.6 AE 1.8 mg/dL vs 2.0 AE 2.3 mg/dL; P = .003). There were no differences in all-cause mortality through 2 years between paclitaxel and no-paclitaxel cohorts (25.5% vs 30.3%; logrank, P = .098). At 3 years and 3.5 years, mortality was significantly lower in the paclitaxel group: year 3, 32.1% vs 39.4% (log-rank, P = .041); year 3.5, 35.2% vs 43.9% (logrank, P = .027). Survival rates were not significantly different in examining subgroups by diabetes, chronic kidney disease, presence of chronic limb-threatening ischemia, or paclitaxel-coated balloon manufacturer. Multivariable analysis demonstrated that age, dialysis, chronic limb-threatening ischemia, chronic kidney disease, and congestive heart failure were independent risk factors for mortality, whereas paclitaxel use was associated with lower mortality. Conclusions: The use of paclitaxel-coated balloons and stents does not increase mortality compared with uncoated devices out to 3.5 years. Paclitaxel-coated devices can be used with continued caution, especially in patients at increased risk of restenosis. Further long-term studies are needed to determine the risk of late mortality. Objective: Our goal was to analyze the utility of the ageadjusted D-dimer cutoff value in patients with clinically suspected deep venous thrombosis (DVT) in an ambulatory care setting, including distal DVTs. Methods: This was an observational cohort study of 606 outpatients older than 18 years presenting with low or moderate clinical suspicion of lower limb DVT (measured by Wells scale). D-dimer levels were obtained, and duplex ultrasound was performed (including femoropopliteal and below-knee veins). We calculated sensitivity, specificity, and positive and negative predictive D-dimer values and when to apply the age-adjusted D-dimer cutoff value (D-dimer threshold = age  10 mg/L). We split patients older than 50 years into 10-year age groups. We constructed receiver operating characteristic curves of the Ddimer test for each group to find the best threshold (defined as the value of D-dimer that gives more specificity, maintaining the maximum possible sensitivity). Results: There were 249 men and 357 women with a mean age of 69.3 years; 41 patients were diagnosed with DVT. At a D-dimer threshold of 250 mg/L, sensitivity was 93%, specificity was 8%, positive predictive value was 7%, and negative predictive value was 94%. When the age-adjusted cutoff level was applied, global sensitivity was 76% and specificity 61%; positive predictive value was 12%, and negative predictive value was 97%. False-negative rate was 24%. We split patients older than 50 years into 10-year age groups: 50 to 60 years, 60 to 70 years, 70 to 80 years, and >80 years. The optimum thresholds were, respectively, 526 mg/L, 442.5 mg/L, 475 mg/L, and 549. mg/L. Conclusions: In our series, the age-adjusted D-dimer cutoff level is not useful in the diagnostic algorithm of DVT. A prospective safety and effectiveness study using endovenous laser ablation with a 400-mm optical fiber for the treatment of pathologic perforator veins in patients with advanced venous disease (SeCure trial) Background: Treatment of pathologic perforator veins (PPVs) can shorten time to healing and reduce recurrence of ulcers in patients with advanced venous disease. Because of limited clinical evidence and device options, widespread adoption of PPV treatment is controversial. The objective of this study was to evaluate the safety and efficacy of endovenous laser therapy using a 400-mm optical fiber to treat PPVs. Methods: This study was a single-arm, prospective, sevencenter, nonblinded clinical study examining patients with advanced skin changes or healed or active ulceration (Clinical, Etiology, Anatomy, and Pathophysiology clinical class C4b, C5, and C6). Patients received treatment with a 1470-nm laser. Procedural technical success and 10-day primary closure were evaluated. All device-related adverse events were reported. Follow-up of patients was continued for 12 months after initial ablation. Results: The primary PPV closure (at 10-day visit) rate was 3% of PPVs were achieved at 1 month, 3 months, 6 months, 9 months, and 12 months, respectively. Statistically significant improvements (P < .05) were seen in patients' quality of life at 1 month, 3 months, 6 months, 9 months, and 12 months compared with screening. The percentage of patients with ulcers (22.9% at screening, 14.1% at 1 month, 13.7% at 3 months, 10.1% at 6 months, 12.3% at 9 months, and 11.1% at 12 months) displayed improvement during the course of the study