key: cord-0040340-pvruhsys authors: Nicoara, Alina; Maldonado, Yasdet; Kort, Smadar; Swaminathan, Madhav; Mackensen, G. Burkhard title: Specific Considerations for the Protection of Patients and Echocardiography Service Providers When Performing Perioperative or Periprocedural Transesophageal Echocardiography During the 2019 Novel Coronavirus Outbreak: Council on Perioperative Echocardiography Supplement to the Statement of the American Society of Echocardiography: Endorsed by the Society of Cardiovascular Anesthesiologists date: 2020-04-11 journal: J Am Soc Echocardiogr DOI: 10.1016/j.echo.2020.04.008 sha: 118fccc830ebe4ccb37943572b8272af563aa168 doc_id: 40340 cord_uid: pvruhsys This statement reflects recommendations based on expert opinion, national guidelines, and available evidence. Our knowledge with regard to COVID-19 continues to evolve, as do our institutional protocols for dealing with invasive and non-invasive procedures and practice of personal protective equipment. Readers are urged to follow national guidelines and their institutional recommendations regarding best practices to protect their patients and themselves. These reports are made available by ASE as a courtesy reference source for its members. The reports contain recommendations only and should not be used as the sole basis to make medical practice decisions or for disciplinary action against any employee. The statements and recommendations contained in these reports are primarily based on the opinions of experts, rather than on scientifically-verified data. ASE makes no express or implied warranties regarding the completeness or accuracy of the information in these reports, including the warranty of merchantability or fitness for a particular purpose. In no event shall ASE be liable to you, your patients, or any other third parties for any decision made or action taken by you or such other parties in reliance on this information. Nor does your use of this information constitute the offering of medical advice by ASE or create any physician-patient relationship between ASE and your patients or anyone else. Protecting healthcare workers and preventing transmission of SARS-CoV-2 should be a top priority during the ongoing COVID-19 pandemic. Transesophageal echocardiography (TEE) examinations carry a heightened risk of SARS-CoV-2 spread in non-intubated patients due to possible direct droplet transmission and/or viral aerosolization and inhalation during insertion/removal of the probe and/or coughing. Although conducting a TEE in an already intubated patient may reduce the risk of viral aerosolization, viral transmission may still occur through direct contact with the patient's secretions, resulting in contaminated hands and surfaces. These infection risks apply not only to echocardiographers, but also to other patients and personnel in the vicinity, as a result of cross-contamination whenever there may have been improper handling or cleaning of the equipment. The performance of TEE examinations, therefore, deserves special consideration in determining appropriate use and special precautions. This statement reflects recommendations based on expert opinion, national guidelines, and available evidence specifically as they pertain to performing safe perioperative TEE. This document will not address specific recommendations during point-of-care surface ultrasound (lung, heart, abdomen, vascular), nor will it address criteria used in the decision making regarding postponing elective procedures or proceeding with cardiac surgical procedures deemed urgent or emergent. Practice guidelines for the use of perioperative TEE were developed by the American Society of Anesthesiologists (ASE) and the Society of Cardiovascular Anesthesiologists 1, 2 . As indicated in the main statement of the ASE on protection during COVID-19 3 , TEE examinations should be postponed or canceled if they are unlikely to change clinical care, or if an alternative imaging modality (e.g. off axis transthoracic echocardiography (TTE) views, ultrasound enhancing agent with TTE) can provide the necessary information. While non-essential TEE examinations should be either deferred or postponed, patients under investigation or confirmed with COVID-19 may still require TEEs in several clinical situations including (1) urgent or emergent cardiac surgery, (2) patients with cardiac co-morbidities undergoing emergent non-cardiac surgery, or (3) hemodynamic instability due to undifferentiated shock in the perioperative period. Deployment of alternative imaging modalities may not always be possible in the perioperative patient population undergoing cardiac surgery and special consideration should be given to triaging these patients on a case-to-case basis. Additionally, TEE provides invaluable dynamic information, paramount to performing a successful procedure in certain clinical situations. Surgical procedures in which the benefit of performing a TEE exam may outweigh the risk of contamination or cross-contamination include but are not limited to the following: (a) Infective endocarditis with valvular and perivalvular involvement (b) Stanford type A aortic dissection, especially in the presence of associated complications (e.g., aortic insufficiency, aortic root involvement, pericardial effusion). (c) Initiation of temporary or durable mechanical circulatory support (d) Myocardial infarction with mechanical complications (e.g., ventricular septal defect, left ventricular wall rupture, papillary muscle rupture). (e) Prosthetic valve assessment There are surgical procedures in which the use of TEE can be supplanted by observing invasively derived hemodynamic data, other imaging modalities (e.g., fluoroscopy, epicardial ultrasound imaging), or direct visualization of the heart in the surgical field, such as coronary artery bypass graft, or endovascular stenting for Stanford type B aortic dissection with peripheral malperfusion. In these procedures, TEE can be considered in situations of severe hemodynamic instability or procedural complications, which require immediate diagnosis and in which the TEE findings would highly impact patient outcome (Figure 1) Where to image? Perioperative TEE examinations will likely be performed in operating rooms, structural heart and catheterization laboratory rooms, or in the intensive care units. Patients with suspected or confirmed COVID-19 infections should undergo surgical or interventional procedures in dedicated COVID-19 operating rooms, or may be admitted in intensive care unit rooms. Specific considerations should be given to entering and especially exiting these spaces in order to limit virus transmission. Proper handling and cleaning of the equipment is critical in prevention of virus transmission to other healthcare providers and other patients. The exact steps to be followed for disinfection of the TEE probe and equipment will depend on local institutional protocols that should be guided 7 by infectious disease experts and resource availability. Plastic covers for the ultrasound machine, its touchable parts (knobs, screen) and transducer ports are commercially available and should be considered in order to reduce bioburden on these "high touch" surfaces with hard-to-clean grooves, slots or crevases (Figure 2) . In order to avoid contamination of surfaces, one person can be designated to probe manipulation and another one to adjusting instrument settings for image optimization and data acquisition, although this approach has to be balanced with PPE availability. As noted in the ASE main document 3 , removal of any non-essential accessory equipment from the ultrasound machine (cart) such as additional alternate transducers, ECG cables, ECG stickers, paperwork, gel (and any other items) will facilitate thorough cleaning and minimize risk for cross contamintation. A practical approach is suggested in the Table. Following a TEE examination, all exposed equipment should be wiped down with the hospital-approved and vendor-recommended disinfection product in the procedure or intensive care room, and in the induction room or anteroom. The TEE probes should also be thoroughly wiped (including handle, cable, and connector), placed in closed containers and transported in those containers to the cleaning facility. The equipment surfaces should stay wet with the disinfection solution for the minimum recommended "wet time" provided on the product label. The educational benefit for trainees from performing TEEs in the perioperative period in patients with suspected or confirmed COVID-19 should be weighed against the potential for prolonging Practice guidelines for perioperative transesophageal echocardiography. A report by the American Society of Anesthesiologists and the Society of Cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography Practice guidelines for perioperative transesophageal echocardiography. An updated report by the American Society of Anesthesiologists and the Society of Cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography ASE Statement on Protection of Patients and Echocardiography Service Providers During the 2019 Novel Coronavirus Outbreak Preventing Infection of Patients and Healthcare Workers Should Be the New Normal in the Era of Novel Coronavirus Epidemics Anesthetic Management of Patients Undergoing Aortic Dissection Repair With Suspected Severe Acute Respiratory Syndrome Coronavirus-2 Infection