key: cord-0039067-47frii8q authors: nan title: Current awareness in biosensors & bioelectronics date: 2003-09-09 journal: Biosens Bioelectron DOI: 10.1016/0956-5663(95)90199-x sha: dc7823c4d8bed56a93427a6ece33721d40064dc7 doc_id: 39067 cord_uid: 47frii8q nan Adeyoju O, Iwuoha EI, Smyth MR*// *Dublin City Univ, Sch Chem Sci, Dublin 9, Rep Ireland Determination of kinetic parameters for the inhibitory effects of organic sulphides on an amperometric peroxide biosensor in non-aqueous media Talanta 1994, 41 (9) 1603 Aizawa M, Haruyama T, Khan GF, Kobatake E, Ikariyama Y//Tokyo Inst Technol, Dept Bioeng, Nagatsuta, Midoriku, Yokohama 227, Japan Electronically modulated biological functions of molecular interfaced enzymes and living cells Biosens Bioelectron 1994, 9 (9-10) 601 Campanella L, Fortuney A, Sammartino MP, Tomassetti M//Univ Roma La Sapienza, Dipt Chim, P Le A Moro 5, 1-00185 Rome, Italy Tyrosinase biosensor response as a function of physical properties of organic solvents Talanta 1994, 41 (8) 1397 Canters GW, Van Pouderoyen G//Leiden Univ, Leiden Inst Chem, Gorlaeus Labs, POB 9502, 2300 RA Leiden, The Netherlands Engineering of electron transfer properties of metallo-proteins Biosens Bioelectron 1994, 9 (9-10) Immobilization of glutamate dehydrogenase on glass derivatives: A method for the assay of glutamates in real samples with simplex optimized automated FIA-system Talanta 1994, 41 (9) 1561 Yao T, Satomura M, Nakahara T//Univ Osaka Prefecture, Coil Engn, Dept Appl Chem, 1-1 Gakuen cho, Sakai, Osaka 593, Japan Amperometric flow-injection determination of glucose, urate and cholesterol in blood serum by using some immobilized enzyme reactors and a poly(1,2-diaminobenzene)coated platinum electrode Anal Chim Acta 1994, 296 (3) 271 Yao T, Tsureyama K, Nakahara T//Address as above. Amperometric flow-injection analysis of purine nucleotides: Comparison of selectivity for hydrolytic cleavage of purine nucleotides Electroanal 1994, 6 (8) Development of an ELISA for quantification of human protein S in cell culture fluids using commercial polyclonal antisera Jlmmunoassay USA Development of an enzyme-linked immunosorbent assay for measurement of fire ant venom-specific IgE Ann Allergy A multicentre study of commercially available ELISA kits for the determination of human IgG subclasses Poly(vinyl alcohol) as a blocking agent in enzyme immunoassays Immunol Invest CH-8057 Zurich, Switzerland Comparison of 2 ELISA systems for detection of antibodies against IBR/IPV and against bovine leukemia virus (German Australia Pulsed amperometric detection of thaumatin using antibody -containing poly(pyrrole) electrodes Analyst USA Falsely high concentration of serum lutropin measured with the Abbott IMx E-18071 Granada, Spain Procedures for Sxs antigen detection by antibody-mediated cytotoxicity tests. A comparative analysis Jlmmunoassay Bdg R-1056319, CH-4002 Basel, Switzerland Development of a magnetic particle-based automated chemiluminescent immunoassay for triasulfuron JAgr Food Chem USA Direct measurement of ATP-dependent proton concentration changes and characterization of a K+-stimulated AT-Pase in pea chloroplast inner envelope vesicles Ukraine Construction and biomedical application of immunosensors based on fiber optics and enhanced chemiluminescence Streptavidin-biotin based time-resolved immunofluorometric assay for direct measurement of high concentrations of human chorionic gonadotropin (hCG) Jlmmunol Method FRG Isolation of serovar-specific leptospiral antigens for use in an enzyme-linked immunosorbent assay (ELISA) compared with the microscopic agglutination test and immunofluorescence J Vet MedB-Zbl Vet B-Infect Address not available A comparison of 4 ELISA kits for the diagnosis of bovine leukosis Focused antigen capture immunoassay Electrophoresis Sweden Expanded gold standard in the diagnosis of Chlamydia trachomatis in a low prevalence population: Diagnostic efficacy of tissue culture, direct immunofluorescence, enzyme immunoassay, PCR and serology Praed St, London W2 1NY, England Limited value of two widely used enzyme immunoassays for detection of Chlamydia trachomatis in women London SW3 6JJ, England Disagreement between the Roche CobasĀ® core and Hybritech TandemĀ®-E PSA assays when measuring free, eomplexed and total serum prostate specific antigen H-1525 Budapest, Hungary A new method for the production of a magnetic immunosorbent used in radioimmunoassay and immunoradiometric assay Japan Serotyping of human rotaviruses in the Tokyo area (1990-1993) by enzyme immunoassay with monoclonal antibodies and by reverse transcription and polymerase chain reaction amplification JMed Virol Australia Development of a sandwich immunoassay for the detection of soluble ovine IL-2Rct chain Sao Paulo, Brazil Development and clinical application of an immunofluorometric assay for intact parathyroid hormone Braz USA Instrument to detect near-infrared fluorescence in solidphase immunoassay Anal Chem IL-91904 Jerusalem, Israel Application of photoisomerizable antigenic monolayer electrodes as reversible amperometric immunosensors JAmer Chem Soc POB 1, 3720 BA Bilthoven, The Netherlands lnterlaboratory comparison of enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescence (IIF) for detection of Bordetella bronchiseptica antibodies in guineapigs Systematic differences between commercial immunoassays for free thyroxine and free triiodothyronine in an external quality assessment program New plastic membrane ion-selective electrode for determination of trimethoprim Japan Pulsed EPR study of manganese g=4.1 signal in plant photosystem II USA Phase fluorometric sterilizable optical oxygen sensor D-52404 Julich, FRG Multichannel flow-injection-analysis biosensor system for on-line monitoring of glucose, lactate, glutamine, glutamate and ammonia in animal cell culture Dept Phy & Analyt Chem, E-33006 Oviedo, Spain Voltammetric study of salbutamol, fenoterol and metaproterenol at unmodified and nation-modified carbon paste electrodes Analyst A-8010 Graz, Austria Simultaneous determination of uric acid, xanthine and hypoxanthine with an electrochemically pretreated carbon paste electrode Fresenius JAnal Chem USA Amperometric monitoring of stimulated catecholamine release from rat pheochromocytoma (PC12) cells at the zeptomole level Anal Chem Disproportionation during electrooxidation of cateeholamines at carbon-fiber microelectrodes Anal Chem Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain Electrochemical oxidative determination of thimerosal in soft contact lens care solutions by cyclic voltammetry Analyst 15213, USA A likely in vivo probe of human circadian timing system function using F-69310 Pierre Benite, France Continuous in vivo monitoring of evoked dopamine release in the rat nucleus accumbens by amperometry Neuroscience Bangalore 560012, Karnataka, India Spectral estimation of EEG signals using cascaded inverse filters lnt D-80333 Munich, FRG Potentiometric thick-film sensor for the determination of the neurotransmitter acetylcholine Analyst D-72762 Reutlingen, FRG Extracellular recording in neuronal networks with substrate integrated microelectrode arrays England Screen-printed voltammetric and amperometric electrochemical sensors for decentralized testing F-59019 Lille, France In vivo pH measurement and imaging of tumor tissue using a pH-sensitive fluorescent probe (5,6-carboxyfluorescein): Instrumental and experimental studies Photochem Photobiol D-72762 Reutlingen, FRG A thin film microelectrode array for monitoring extracellular neuronal activity in vitro Japan Determination of calcium content in individual biological cells by inductively coupled plasma atomic emission spectrometry Anal Chem Japan Light-induced changes in cytosolic pH in leaf cells of Egeria densa: Measurements with pH-sensitive microelectrodes USA In vivo diagnosis of cervical intraepithelial neoplasia using 337 nm-excited laser-induced fluorescence Egypt Metformin-selective PVC membrane electrode based on metforminium phosphomolybdate ion pair d Dept Analyt Chem, E-14004 Cordoba, Spain Fluorimetric determination of alkaline phosphatase activity in human serum by use of a flow-through biosensor JBiotechnol United Arab Emirates Adsorptive cathodic stripping voltammetric determination of theophylline at a hanging mercury drop electrode Analyst Japan Subfemtomole detection of catecholamine with interdigirated array carbon microelectrodes in HPLC (Letter) Anal Chem Assessment of body composition by skinfold anthropometry and bioelectrical impedance technique: A comparative study J Parent Enter Nutr Ctr Studies Sensory Impairment Aging & Metab, Res Branch, Guatemala City 0101 l, Guatemala The interobserver reproducibility of bioelectfical impedance analysis measurements in infants and toddlers Electroanal 1994, 6 (8) 617 Harris B, Gath I, Rondouin G, Feuerstein C// Weizmann Inst Sci, Ctr Brain Res, IL-76100 Rehovot, Israel On time delay estimation of epileptic EEG IEEE Trans Biomed Eng 1994, 41 (9)