key: cord-0036154-4lavnvgo authors: Yetisen, Ali Kemal title: Point-of-Care Diagnostics date: 2014-12-04 journal: Holographic Sensors DOI: 10.1007/978-3-319-13584-7_1 sha: 329da5fc5b23d579a8b2b9aceb99d553b94e86d8 doc_id: 36154 cord_uid: 4lavnvgo Rapid tests that are low-cost and portable are the first line of defence in healthcare systems. Dipstick and lateral-flow are the two universal assay formats as they are lightweight and compact, and provide qualitative results without external instrumentation. However, existing formats have limitations in the quantification of analyte concentrations. Hence, the demand for sample preparation, improved sensitivity and user-interface has challenged the commercial products. Recently, capabilities, sensors and readout devices were expanded to multiplexable assays platforms, which might transcend the capabilities of existing design format of diagnostic tests. This chapter outlines the evolution of diagnostic devices and current trends in the development of qualitative and quantitative sensing devices for applications in healthcare, veterinary medicine, environmental monitoring and food safety. The chapter also discusses design parameters for diagnostics, their functionalisation to increase the capabilities and the performance, emerging sensing platforms and readout technologies. The factors which limit the emerging rapid diagnostics to become commercial products are also discussed. limited [6, 7] . Other trends include increase in healthcare associated infections [8, 9] , preservation of the life span of cost-effective drugs [10] , increase in spurious/ counterfeit medicines [11] , and mitigating the epidemic-to-pandemic transitions of infectious diseases [12] . In terms of impact, low-cost diagnostics will reach underserved communities. Low-cost diagnostics that can allow local communities in developing regions to improve healthcare [13] , environmental safety [14] , animal health [15, 16] , and food quality [17] will play key roles in the United Nation's Post-2015 Millennium Development Goals. In the developing world, medical diagnostics for poverty-related conditions are outdated. In the absence of the diagnostic equipment, healthcare personnel make their decisions based on symptoms. WHO's Integrated Management of Childhood Illness (IMCI) is a diagnosis guideline based on signs and symptoms with minimum or no instrumentation [18, 19] . However, such systematic guidelines have limitations in (i) distinguishing asymptomatic diseases, (ii) detecting multiple infections, (iii) identifying the disease window period, and (iv) quantifying concentrations of target analytes. Eventually, the development and delivery of affordable testing technologies can enable local communities that lack access to technical and human resources present in urban areas. The deficiency in diagnostics and healthcare resources can have an irreversible negative effect on developing economies. Such an economic impact is pronounced for non-infectious as well as infectious diseases. For example, the Ebola virus epidemic in West Africa has overwhelmed the healthcare systems of Liberia, Sierra Leone, Guinea and their neighbouring countries since 2013. Such outbreaks have a profound impact on the development of emerging economies. Currently, it is difficult to identify Ebola because its symptoms such as fever are generic, also seen in commonly occurring diseases such as malaria and typhoid fever. Existing laboratory techniques are based on transcription polymerase chain reaction (RT-PCR) and quantitative PCR; however, they are not portable and affordable in the developing world. Other rapid tests suffer from sensitivity and selectivity, which may put the entire healthcare system at risk by misdiagnosing patients. Yet, recent Ebola epidemic is an example of many ongoing difficulties in healthcare systems and highlights the dire need for the development of low-cost rapid diagnostics. While the main application of rapid tests is in medical diagnostics, such assays are also necessary for veterinary testing, environmental monitoring and food quality testing. Low-cost diagnostics would allow farmers and entrepreneurs in the developing world to assess the quality of their products and mitigate potential risks due to enterohemorrhagic strain of E. coli (O157:H7) and Salmonella in undercooked meat and poultry products [17] . Low-cost diagnostics are also required in testing water supplies. Inadequate environmental monitoring capabilities were highlighted by the cholera epidemic in Haiti after the earthquake in 2010 [20] [21] [22] [23] [24] . Although the cholera epidemic took most people by surprise, it wasn't totally unexpected since Haiti ranked last out of 147 countries surveyed in the 2002 Water Poverty Index [25] . Due to globalisation, such epidemics also concern the developed nations. The development of low-cost, rapid quantitative diagnostics will aid in screening large regions and populations. For the development of rapid diagnostics, WHO has outlined a set of criteria corresponding to the acronym ASSURED: Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment free and Deliverable to those who need it [10] . For the developing world, the trend towards low-cost is a priority; however, clinically useful sensitivity and specificity from rapid diagnostics assays are also required. Operating with lowvolume samples without manual manipulation, being portable and functioning without sharps such as needles are considered desirable characteristics of rapid assays. Hence, the development of robust diagnostic tests can enable individuals and local communities to monitor their health condition and timely mitigate the spread of diseases. Historical assay formats for point-of-care testing are dipsticks and lateral flow devices. In the 1950s, the earliest paper-based strip test emerged for the quantification of the concentration of glucose in urine, and this product was marketed in the 1960s [26] . The principle of operation of the assay was based on glucose oxidase, and developed colours were compared to a reference chart for interpretation. Today, commercial urinalysis strip tests are adapted for a wide range of analytes. Traditionally, these tests are semi-quantitatively read with a colorimetric chart or with detection equipment such as CLINITEK Status ® + Analyzer (Siemens) or Urisys 1100 ® Urine Analyzer (Roche) . In the 1950s, parallel to the development of strip tests, latex agglutination assays and radioimmunoassays were also developed [27, 28] . Since the 1970s, nitrocellulose matrices have been used as a substrate for molecular detection [29] [30] [31] . In the 1980s, serological lateral-flow tests emerged [32] . The most notable example is the human pregnancy test, which was derived from the development of hCG betasubunit radioimmunoassay [33] . Since then, commercial rapid lateral flow assays expanded beyond clinical diagnostics to veterinary, food, environmental applications, bio-defence and drug abuse (Table 1 .1). Rapid diagnostic tests often have lower specificity and sensitivity than their laboratory bench counterparts. The majority of these tests are simple and provide yes/no answer, where response time is critical to the user. The commercial rapid tests have various geometries and configurations with/out housing units ( Fig. 1.1) . Figure 1 .1d shows a multiplexed lateral-flow assay, which allows the analyses of a single sample simultaneously. Lateral-flow immunoassays have two major configurations: Direct (i.e. double antibody sandwich assays) and competitive (i.e. inhibitive) formats. The assay format typically consists of a number of segments: sample pad, conjugate pad, reaction membrane and an absorbent pad ( Fig. 1.1e) . These segments are supported by a backing card and enclosed in a plastic cassette (housing). Another format in rapid diagnostics is flow-through (vertical), which is relatively more complex than lateral flow format, and its execution requires (i) sample placement, (ii) washing and (iii) addition of analyte-colloidal gold conjugates [68] (Fig. 1.1f) . Most of the commercial assays require sample preparation. [55] [56] [57] [58] Food allergens: Almond, brazil nut, casein, cashew/pistachio, coconut, hazelnut, lupin, macadamia nut, mustard, peanut, sesame, soy, walnut, whole egg, β-lactoglobulin, total milk, crustacea, and gliadin/gluten [55, 56] Genetically modified organisms: Bulk grain, seed and leaf, toasted meal, and corn Comb 7 Traits [55] Veterinary drug residues: Chloramphenicol, nitrofuran AMOZ/ AOZ/AHD, clenbuterol, ractopamine, beta agonists, dexamethasone, ciprofloxacin, quinolones, β-Lactam antibiotics, flunixin, aminoglycoside, amphenicol, enrofloxacin, macrolide, sulphonamide, tetracycline, and melamine [55] [56] [57] Beverage: Methanol contamination, acetic acid, citric acid, D-glucose, D-fructose, lactose, milk (lactic acid, urea), and wine (acetic acid, total acidity, glucose, fructose, L-lactic acid, L-malic acid, and sucrose) [56] Pesticide residues: Organophosphates, thiophosphates, and carbamates [56] Seafood analysis: Amnesic shellfish poisoning (ASP), marine biotoxins (okadaic acid), histamine, and sulphite residues [56] Species identification: Pork, horse, beef, fish, goat, poultry, rabbit and sheep [56] Environmental monitoring devices Water testing: Algae, alkalinity, aluminium, ammonia, arsenic, bleach, boron, bromine, cadmium, calcium hardness, carbon dioxide, chelant, chloride, chlorine, chromate, chromium, conductivity, copper, cyanuric acid, cyanide, detergents, dissolved oxygen, faecal streptococci, E.Coli and faecal coliforms, filming amine, fluoride, formaldehyde, glutaraldehyde, hardness, hydrazine, hydrogen peroxide, iodine, iron, lead, magnesium, manganese, molybdate/molybdenum, morpholine, nickel, nitrate, nitrite, oil in water, organophosphate, dissolved oxygen, ozone, quaternary ammonium compounds, peracetic acid, pH, phosphate, phosphonate, polyphosphates, polyquat, potassium, Pseudomonas aeruginosa, salinity, silica, sulphate, sulphide, sulphite, turbidity, total dissolved solids, tannin/lignin, tolcide PS biocide, and zinc [59] [60] [61] [62] [63] [64] Soil: Humus, organic matter, pH, and plant tissue macronutrient (texture) [60] (continued) Typical approaches include the removal of contaminants from the samples to improve selectivity and sensitivity, and decrease the turnaround time. Additionally, the sample might require further processing to improve the signal-to-noise ratio. Sample preparation suffers from inhomogeneity, interfering agents, inhibitors, and it requires increasing the viscosity of samples such as whole blood and food samples. Increasing the sensitivity requires tedious sample preparation steps for low concentrations of target molecules or cells. The ideal sample preparation step should be cost-effective and is potentially executed in a single step. The desired outcome of the sample preparation is concentrating the target analyte(s) and reducing the background noise due to matrix interferences. Lateral-flow tests are low-cost, lightweight, portable, but the growing demand for higher sensitivity is challenging its current format [68] . For , c ImmunoCard STAT! ® E. coli O157 Plus (Meridian Bioscience), d A multiplex lateral-flow assay. RAID ™ 5 for biological threat detection (Alexeter Technologies), e Schematic of the lateral-flow assay, and f flow-through assay. Adapted from Ref. [69] with permission from The Royal Society of Chemistry example, cardiac markers, biothreat and single cell detection require sensitivities that are not achievable with the existing assays. For these applications, lateral-flow tests must evolve and incorporate novel materials and labelling approaches. Progress in detection/quantification technologies, readout devices and manufacturing techniques will increase the reproducibility and sensitivity of lateral-flow assays. However, all these new advances must maintain the ultimate attractiveness of rapid tests: Sampleto-answer in a single step. A wide array of sensing mechanisms has been proposed for point-of-care diagnostic devices. Applications for such sensors include medical diagnostics, veterinary testing, environmental monitoring and food pathogen testing (Table 1. 2). Sensing mechanisms demonstrated, with the exception of molecular dyes, required handheld readers. Excluding other types of sensors can be attributed to high costs, powering requirements and incompatibility with point-of-care assays. Molecular and enzymatic dyes are the simplest and most commonly used detection methods, which are semi-quantitatively interpreted by a colour reference chart. Urinalysis test strips such as Multistix (Siemens) and Chemstrip (Roche) are based on colorimetric reagents (Table 1. 3). In advanced assays such as paper-based microfluidic devices, multiple detection zones are employed to capture different analytes within the same assay. Such multiplexed assays can be fabricated by printing wax channel-shaped patterns on paper/nitrocellulose, followed by heat treatment to form hydrophobic barriers in the matrix. The patterned regions can be spotted with enzymes, acid-base indicators or dyes in confined zones. Usually, a single inlet wicks the sample, which is distributed to the confined regions to react with the immobilised reagents. pH-, glucose-and protein-sensitive reagents have been used in paper-based microfluidic devices [70, 73] . In the glucose assay, a positive result is observed when the colour shifts from clear to brown due to the enzymatic oxidation of iodide to iodine. Similarly, a positive result in protein assays is interpreted from a colour change of tetrabromophenol blue from yellow to blue [70, 73] . Up to date, multiplex colorimetric assays included medical diagnostics [81, 87, 90, 91] , environmental tests [76, 83, 84, 86, 89] , and food quality tests [77, 88] (Fig. 1.2a) . A disadvantage of colorimetric sensors is the inhomogeneity of the colour distribution and the coffee ring effect in the detection zones, and thus, the judgment of the final colour is challenging by eye [73] . In addition, colorimetric sensors are interfered by the background colour of the paper or the sample. For example, blood assays require either usage of serum/plasma samples or a red blood cell filter. Despite its drawbacks, colorimetric sensing is widely used, and it can also be quantified by a handheld reader [141, 142] or a smartphone camera [72, 143] . Electrochemistry and ion-selective electrodes have been explored widely due to their well-known principle of operation and maturity. Traditionally, electrochemical sensors have three electrodes: a counter electrode, a working electrode, and a reference electrode. In paper-based assays, carbon ink was used for the counter and the working electrode, whereas silver/silver chloride ink was used for the fabrication of the reference electrode. The reaction zones comprised this multiple-electrode mechanism ( Fig. 1.2b) . Electrochemical sensors allowed the detection of glucose [94, 95] , lactate [94, 95] , uric acid [94] , cholesterol [95] , tumour markers [101] , dopamine [106] and drugs [107] . Other studies described heavy metal sensors for environmental monitoring [94, 96, 99, 100] . As compared to colorimetric reagents, the fabrication of electrochemical sensors required an additional deposition step of conductive inks on the paper matrix. All these electrodes and electronic wires were screen printed using graphite and silver inks, respectively. When the sample was introduced to the device, it was wicked up into the sensing zones and the amperometric measurement was initiated via a glucometer. Alternatively, gold can be sputtered on the paper matrix through a shadow mask for the deposition of electrodes [107] . Such electrodes can be characterised by cyclic and square wave voltammetry, and chronoamperometry. In contrast to colorimetric reagents, electrochemical sensors respond within seconds and have sensitivities down to nM [145] . Electrochemical detection is also independent of the ambient light and is less prone to interference from the colour/deteriorations of substrate. Although the attributes of electrochemical detection such as maturity and suitability for miniaturisation are attractive, the requirement for a readout device increases its complexity and the cost per test. Functionalised colloidal gold and monodisperse latex are the historical sensing reagents for lateral-flow assays, which do not require a readout device for qualitative results [146] . Lateral-flow tests employ antibody-conjugated gold NPs, which have extinction coefficients that are higher than common organic dyes. Inkjet printers have been used to deposit the NPs for multiplex detection on filter paper [111] . Other NP-based assay studies focused on improving the sensitivity of current lateral-flow tests by using paper network platforms. The 2D nitrocellulose-based networks enabled multistep processes to amplify the signal in immunoassays to improve the limit of detection [115, 147] . These cards contained reagents stored dry and the assay was activated by wicking the sample in a single-user step. They were capable of multistep processes such as delivering rinse buffers and signal amplification reagents to the capture zones. These devices were demonstrated by using porous materials such as nitrocellulose and cellulose depending on the sensing application. Other 2D paper networks involved integrating the inlets of a number of lateral flow assays [112] (Fig. 1.2c) , adopting folding techniques [119] and microplate paper platforms [120] . NP-based detection has been demonstrated with metabolites [109, 111, 113, 117, 121, 147] , bacterial agents [112] in disease diagnosis such as HIV [119] , malaria [115] , tuberculosis [120] and in environmental monitoring [114, 118] . To multiplex the assay, monodisperse latex can be coupled with fluorescent and coloured dyes, and para/magnetic components. For example, conjugated with dark dyes, monodisperse latex particles exhibit high contrast on nitrocellulose or paper. Additionally, latex particles can be utilised with different colours or fluorescent dyes. CL is based on the emission of light generated by a chemical reaction. In the presence of reactants A (luminol) and B (H 2 O 2 ), and a catalyst or excited intermediate (3-aminophthalate), light is produced along with side products. Peroxidase catalyses the oxidation of luminol to 3-aminophthalate, and the decay of the excited state (◊) to a lower energy level results in light emission, which can be enhanced by using phenol derivatives such as p-iodophenol. A typical example of CL is the glow stick, which is based on the reaction of peroxide with a phenyl oxalate ester ( [products] + light). In rapid diagnostics, CL has been explored for the detection of glucose and uric acid [130] and tumour markers [132, 148] . Glucose and uric acid assays were based on oxidase reactions coupled with chemiluminescence reactions of a rhodanine derivative with the generated H 2 O 2 in an acidic medium [130] . Uric acid was determined through a chemiluminescence reaction between the rhodanine derivative (3-p-nitrylphenyl-5-(40-methyl-20-sulphonophenylazo) rhodanine) and H 2 O 2 [131] . Studies on the detection of tumour markers involved fabricating sandwich-type immunoassays with a typical luminol-H 2 O 2 chemiluminescence system catalysed by Ag 0 NPs [132] . Detection of tumour markers was also achieved by sandwich CL-ELISA with antibodies that were covalently immobilised on a chitosan modified paper zone through glutaraldehyde cross-linking [148] . Correlating the concentration of the analyte and the peak intensity of the emitted light allowed quantitative analysis. This sensing mechanism is based on luminescence generated by electrochemical reactions. When electrochemically generated intermediates undergo exergonic reactions, they result in an electronically excited state. This state emits light upon relaxation to a lower level state, and therefore it enables readouts without the requirement for a photodetector. ECL has the advantages of both luminescence and electrochemistry. An ECL sensor based on orange luminescence was demonstrated through the detection of 2-(dibutylamino)-ethanol (DBAE) and nicotinamide adenine dinucleotide by readouts of luminescence [123] . The principle of ECL sensor was based on Ru bpy ð Þ 2þ 3 and DBAE. At the electrode, the amine was oxidised and formed a radical cation [DBAE ▪ ] + , followed by deprotonation to create a DBAE ▪ radical, which reduced Ru bpy ð Þ 3þ 3 to an excited state. Eventually, Ru bpy ð Þ 2þÁ 3 emitted light at 620 nm while relaxing to the ground state [149] . This mechanism served as a coreactant that was oxidised solely by the electrode. In ECL, the electrochemical potential initiated and controlled the chemiluminescence reaction. The electrodes were printed using screen printing and adding an ECL active luminophore followed by drying. The substrates were laminated onto a Zensor screen-printed electrode using an office laminator. The cyclic voltammetry of Ru bpy ð Þ 2þ 3 was used to characterise the electrodes. After the lamination step, an incision was made in the laminate layer. After the introduction of the sample to the assay, the potential was stepped from 0 to 1.15 V for a short period to initiate the ECL. The initiation can be achieved by shifting the potential to a level more positive than the oxidation potential of the ruthenium complex. Chronoamperometry was adopted to generate ECL since it provided control over the reaction time ( Fig. 1.2d) . The ECL readouts were taken with a camera phone housing to block the ambient light. ECL was connected to the mobile phone battery to obtain a short pulse of low voltage. In addition to these drawbacks, ECL required a photomultiplier tube, which was costly in a miniaturised form. The data was analysed based on the red pixel intensity of the ECL emission, which was correlated with a calibration curve, hence the analyte concentration. Other applications to date included sensing tumour markers [103, 124, 126] and ions [128] . This detection mechanism was first demonstrated on paper microzone plates. Although paper-based plates are known [150] [151] [152] [153] , they have recently been suggested for quantitative fluorescence measurements. These paper plates require low sample volumes; 12.5 pmol of fluorescein isothiocyanate-labeled bovine serum albumin generated a relative fluorescence of 2,700 ± 850 a.u. [133] . Although concentration sensitivity and mass sensitivity were comparable with plastic plates, the average relative standard deviation for the replicates of all concentrations was higher. This limitation was attributed to light scattering on the cellulose fibres and the influence of the index of refraction between cellulose and air. Although paperbased plates were suggested as alternatives to conventional plastic multiwell plates, their interpretation required a microplate reader. Other notable studies adopting fluorescent sensing included paper strips comprising DNA-conjugated microgels (MG) for DNA detection [134] . Sensing DNA was accomplished by: (i) targeting DNA promoted ligation of a DNA primer to the MG-bound DNA, (ii) rolling circle amplification (RCA) between the primer and a circle DNA, and (iii) hybridisation of the RCA products and a fluorescent DNA probe. Another study reported a portable device for the growth of bacteria or the amplification of bacteriophages. A fluorescent mCherry reporter was used to quantify the growth of bacteria and the concentration of arabinose [87] (Fig. 1.2e) . Another paper-based platform involving fluorescent sensing described the use of non-enzymatic nucleic acid circuits based on strand exchange reactions for the detection of target sequences [135] . Overall, although fluorescence sensing brings new capabilities to point-of-care diagnostics, the feasibility requires reduction in cost and miniaturisation of fluorescence readers. Bacterial quorum signalling (QS) molecules, N-acyl homoserine lactones (AHLs), have been used as a sensing mechanism [140] . The bacterial cell-based sensing system comprised two main components: (i) AHL-mediated QS regulatory system as recognition elements, and (ii) β-galactosidase as the reporter enzyme. The bacterial cells were inoculated on paper by liquid drying. The paper strip biosensor detected low concentrations (0.1 nM) of AHLs in saliva. The advent of synthetic biology will accelerate the development of whole-cell based biosensors. To expand the current capabilities of point-of-care diagnostics, the materials, sensors and readout devices need to evolve. Extending beyond strip tests and lateral-flow design to multiplexed miniaturised assay configurations will put the existing diagnostics in a context that will allow differentiation of conditions with similar symptoms and improve the treatment options. Biofunctional materials and synthesis of reversibly responsive compounds could lead to reusable tests, which might be applicable to conditions where frequent measurements are required. The control over structural design parameters, advances in deposition of materials through printing will play greater roles in the realisation of the new generation diagnostics. Studies on substate-protein/enzyme interactions, surface energy, release characteristics, assay decay will gain momentum in the realisation of diagnostics beyond R&D. Optimisation of capillary flow parameters in lateral-flow devices and advanced microfluidic devices will allow construction of assays with improved control and sensitivity. To date, limited studies in microfluidic platforms have employed unprocessed samples. Incorporation of sample preparation should not be overlooked. Furthermore, the performance of assay after long-term storage, and time-consuming sensor response in colorimetric test require further investigations. Sensing and detection technologies will also evolve. The search for sensing, quantification and readout within a single equipment-free assay will play a greater role in future diagnostics. These attributes may include user-friendly, fool-proof, text/quantity-reporting capabilities and unexplored sensing mechanisms such as paramagnetic particles, quantum dots, coloured latex particles, and genetically engineered whole cells based on synthetic biology, and other novel materials including graphene, plasmonic materials, and printable gratings [154] [155] [156] [157] [158] [159] . In improving the sensitivity and providing a user-friendly interface, bioinspired photonic structures, colloidal crystal arrays, diffraction gratings and holographic sensors can offer newer capabilities and readout approaches [160] [161] [162] [163] [164] [165] . Some of these sensing and readout mechanisms might not require physically blocking or shaping the substrate for multiplexing. Although significant time has been devoted to quantification with smartphones/handheld readers, equipment-free approaches should not be overlooked. The use of external readers is a barrier for existing assays, yet this requirement will be a greater challenge in adopting newer sensing platforms. The fast-growing mobile phone market in the developing world has made camera phones a potential platform for quantitatively reading diagnostic assays, and this may standardise the readout devices with improved connectivity [166, 167] . Novel approaches towards instrument-free quantification of analytes will be important contributions to the field. Additionally, the trends show that the microfluidic assay formats will be exploited further by the in vitro diagnostics industry [168] [169] [170] . All these advances will lead to multiplexed diagnostics that are capable of identifying the specific etiological agent that causes a particular syndrome, which is a goal that has not been achieved yet. Such assays can explore less utilised clinical samples such as tear fluid with contact lens sensors [171] . Existing prototypes need to be transformed into highly reproducible diagnostic devices. Having performance data does not always yield efficacy after deployment. Possible small-scale trials should experiment with the feasibility and cost-effectiveness after scaling up. The ultimate test in the realisation of diagnostics depends on the acceptance from experts in the commercial diagnostics industry. Today, the rapid diagnostics business is based on a standard lateral flow format, involving the use of nitrocellulose as the reaction matrix. The lateral-flow format is the only ubiquitous, universally applicable platform that can be utilised for simple, qualitative, low cost point-of-care applications, while also having enough capability to be functionalised for highly sensitive, fully quantified, multiplexed assays. Hence, the industrial partners are seeking technologies that have improved capabilities, sensitivity, specificity, and compatibility with the existing manufacturing processes. Only low cost is not enough to achieve market penetration in diagnostics. The value of the low-cost and multiplexed diagnostics will be realised upon reaching communities, where they are needed the most. Who's going broke? Comparing growth in public healthcare expenditure in ten OECD countries Pharma 2020: The vision. PricewaterhouseCoopers 3. Medicines and older people implementing medicines-related aspects of the NSF for older people (2001) Department of Health A lab the size of a postage stamp Lab-on-achip devices and micro-total analysis systems Critical role of developing national strategic plans as a guide to strengthen laboratory health systems in resource-poor settings Strengthening health human resources and improving clinical outcomes through an integrated guideline and educational outreach in resource-poor settings: a cluster-randomized trial Improving blood safety in resource-poor settings Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysis Requirements for high impact diagnostics in the developing world Counterfeit antiinfective drugs Point-of-care diagnostics for global health Microfluidic diagnostics for the developing world Water quality for ecosystem and human health (2008) 2 edn. GEMS/Water programme office Next Generation Diagnostics 15. Animal health and the millenium development goals (2010) Animal production and health division Emerging diseases and implications for Millennium Development Goals in Africa by 2015-an overview Global strategy for food safety: safer food for better health Effect of implementation of Integrated Management of Neonatal and Childhood Illness (IMNCI) programme on neonatal and infant mortality: cluster randomised controlled trial Integrated Management of N, Childhood Illness Evaluation Study G (2014) Effect of implementation of Integrated Management of Neonatal and Childhood Illness programme on treatment seeking practices for morbidities in infants: cluster randomised trial Cholera tightens grip on Haiti Transmission dynamics and control of cholera in Haiti: an epidemic model How many cholera deaths can be averted in Haiti? Responding to cholera in post-earthquake Haiti Cholera epidemic in Haiti is blamed on poor sanitation Lack of clean water exacerbates cholera outbreak in Haiti Simple specific test for urine glucose The latex fixation test. I. Application to the serologic diagnosis of rheumatoid arthritis Quantitative aspects of the reaction between insulin and insulin-binding antibody Detection of specific sequences among DNA fragments separated by Gel-Electrophoresis Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications Isolation and partial characterization of the drosophila alcohol dehydrogenase gene A dot-immunobinding assay for monoclonal and other antibodies A radioimmunoassay which specifically measures human chorionic gonadotropin in the presence of human luteinizing hormone Swiss Precision Diagnostics Multistix® 10 SG Reagent Strips YD diagnostics URiSCAN Strips Diagnostics Division Lateral flow immunoassay Paper-based microfluidic point-of-care diagnostic devices Patterned paper as a platform for inexpensive, low-volume, portable bioassays Fabrication of paper-based microfluidic device using printed circuit technology Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis Inkjet-printed microfluidic multianalyte chemical sensing paper Use of multiple colorimetric indicators for paper-based microfluidic devices Determination of glucose and uric acid with bienzyme colorimetry on microfluidic paper-based analysis devices Reagentless bidirectional lateral flow bioactive paper sensors for detection of pesticides in beverage and food samples Development of a bioactive paper sensor for detection of neurotoxins using piezoelectric inkjet printing of sol-gel-derived bioinks Paper-based ELISA Paper diagnostic for instantaneous blood typing Validation of paper-based assay for rapid blood typing Paperbased microfluidic devices for analysis of clinically relevant analytes present in urine and saliva A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing beta-galactosidase-based colorimetric paper sensor for determination of heavy metals Solvent colorimetric paper-based polydiacetylene sensors from diacetylene lipids Paper-based vapor detection of hydrogen peroxide: colorimetric sensing with tunable interface Polydiacetylene paper-based colorimetric sensor array for vapor phase detection and identification of volatile organic compounds Portable self-contained cultures for phage and bacteria made of paper and tape Development of a paper-based analytical device for colorimetric detection of select foodborne pathogens Microfluidic paperbased analytical device for particulate metals Measuring markers of liver function using a micropatterned paper device designed for blood from a fingerstick A paper-based multiplexed transaminase test for low-cost, point-of-care liver function testing Microfluidic paper-based analytical device for aerosol oxidative activity A paper-based device for measurement of reactive phosphate in water Electrochemical detection for paper-based microfluidics Integration of paper-based microfluidic devices with commercial electrochemical readers Electrochemical sensing in paper-based microfluidic devices Paper-based electrochemical sensing platform with integral battery and electrochromic read-out Electrochemical detection in a paper-based separation device Paper disk on screen printed electrode for one-step sensing with an internal standard Electrochemical detection of Pb and Cd in paper-based microfluidic devices A disposable paper-based electrochemical sensor with an addressable electrode array for cancer screening Paper-based three-dimensional electrochemical immunodevice based on multi-walled carbon nanotubes functionalized paper for sensitive point-of-care testing Battery-triggered microfluidic paper-based multiplex electrochemiluminescence immunodevice based on potentialresolution strategy Electrochemical immunoassay on a 3D microfluidic paper-based device Paper-based ion-selective potentiometric sensors Sodium dodecyl sulfate-modified electrochemical paper-based analytical device for determination of dopamine levels in biological samples Separation and electrochemical detection of paracetamol and 4-aminophenol in a paper-based microfluidic device An electrochemical gas sensor based on paper supported room temperature ionic liquids Paper-based bioassays using gold nanoparticle colorimetric probes Aptamer-based origami paper analytical device for electrochemical detection of adenosine Inkjet-printed paperfluidic immuno-chemical sensing device Paper based point-of-care testing disc for multiplex whole cell bacteria analysis Paper bioassay based on ceria nanoparticles as colorimetric probes Simple and rapid colorimetric detection of Hg(II) by a paper-based device using silver nanoplates Twodimensional paper network format that enables simple multistep assays for use in lowresource settings in the context of malaria antigen detection Paper-based fluoroimmunoassay for rapid and sensitive detection of antigen Low-cost fabrication of paperbased microfluidic devices by one-step plotting Simple silver nanoparticle colorimetric sensing for copper by paper-based devices A paper and plastic device for performing recombinase polymerase amplification of HIV DNA Gold on paper-paper platform for Au-nanoprobe TB detection Towards protein assays on paper platforms with potentiometric detection All-integrated and highly sensitive paper based device with sample treatment platform for Cd(2+) immunodetection in drinking/ tap waters Electrogenerated chemiluminescence detection in paper-based microfluidic sensors Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing Battery-triggered ultrasensitive electrochemiluminescence detection on microfluidic paper-based immunodevice based on dual-signal amplification strategy Paper-based electrochemiluminescent 3D immunodevice for lab-on-paper, specific, and sensitive point-of-care testing Quantum dot (QD)-modified carbon tape electrodes for reproducible electrochemiluminescence (ECL) emission on a paper-based platform Three-dimensional paper-based electrochemiluminescence device for simultaneous detection of Pb(2+) and Hg(2+) based on potential-control technique Paper-based electrochemiluminescent screening for genotoxic activity in the environment Microfluidic paper-based chemiluminescence biosensor for simultaneous determination of glucose and uric acid A novel chemiluminescence paper microfluidic biosensor based on enzymatic reaction for uric acid determination 3D origami-based multifunction-integrated immunodevice: low-cost and multiplexed sandwich chemiluminescence immunoassay on microfluidic paper-based analytical device Paper microzone plates Detection of DNA using bioactive paper strips DNA circuits as amplifiers for the detection of nucleic acids on a paperfluidic platform Naked eye detection of lung cancer associated miRNA by paper based biosensing platform Paper-based solid-phase nucleic acid hybridization assay using immobilized quantum dots as donors in fluorescence resonance energy transfer Development of a disposable and highly sensitive paper-based immunosensor for early diagnosis of Asian soybean rust Lab-on-paper with dual electrochemical/colorimetric determination of gold and iron Paper strip whole cell biosensors: a portable test for the semiquantitative detection of bacterial quorum signaling molecules Quantifying colorimetric assays in paper-based microfluidic devices by measuring the transmission of light through paper A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader Point-of-care colorimetric detection with a smartphone Chemstrip 10 MD package insert Electrochemical Sensors The place of gold in rapid tests Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format +)/DBAE electrochemiluminescence system by dopamine Testing-paper and method of making same Applications of confined spot tests in analytical chemistry: preliminary paper Microchemical techniques in solving industrial problems Computational modelling of a graphene Fresnel lens on different substrates Enhanced reflection from inverse tapered nanocone arrays Graphene based ultra-thin flat lenses Printable surface holograms via laser ablation Plasmonic nanoparticle scattering for color holograms Polarization switchable diffraction based on subwavelength plasmonic nanoantennas Holographic sensors: three-dimensional analyte-sensitive nanostructures and their applications Computational modelling and characterisation of nanoparticle-based tuneable photonic crystal sensors Light-directed writing of chemically tunable narrow-band holographic sensors Pulsed laser writing of holographic nanosensors Reusable, robust, and accurate laser-generated photonic nanosensor Nanocrystal bragg grating sensor for colorimetric detection of metal ions The regulation of mobile medical applications A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests A microsystem-based assay for studying pollen tube guidance in plant reproduction Patent protection and licensing in microfluidics Commercialization of microfluidic devices Contact lens sensors in ocular diagnostics