key: cord-0034852-556qr3gg authors: Xu, Zhonglin; Zhou, Bin title: Calculation of Air Change Rate date: 2016-12-01 journal: Dynamic Isolation Technologies in Negative Pressure Isolation Wards DOI: 10.1007/978-981-10-2923-3_5 sha: ddf2595f4157338d61f84c05ebb679bc93f0e8c1 doc_id: 34852 cord_uid: 556qr3gg In order to dilute and effectively remove the bioaerosol in the negative pressure isolation ward, a certain amount of flow rate, i.e., the air change rate, is needed. Specified flow rates of the dilution air and the outdoor air "Guidelines for Preventing the Transmission of Mycobacterium tuberculosis in Healthcare Facilities" issued by CDC in U.S.A. In new-built or renovated isolation ward for prevention of airborne transmission, the air change rate >12 h −1 and the outdoor air volume >2 h −1 ASHRAE manual (2003) "Health Care Facilities" [1] In isolation ward, the flow rate of dilution air >6 h −1 (based on requirement for odor and thermal comfort) UK "Guidance on the prevention and control of transmission of multiple drug-resistant Tuberculosis" [1] In new-built or renovated isolation ward for prevention of airborne transmission, the flow rate of dilution air ! 12 h −1 and the outdoor air volume ! 2 h −1 CDC in U.S.A. "Guidelines for environmental infection control in health care facilities" [1] In newly-built ward, the air supply volume ! 12 h −1 . In existing ward, the air supply volume ! 6 h −1 . AIA in U.S.A. "Guidelines for design and construction of hospital and health care facilities" [1] In isolation ward for prevention of airborne transmission, consulting rooms for emergency or radiotherapy, the flow rate of dilution air ! 12 h −1 and the fresh air volume ! 2 h −1 DHHS in U.S.A. "Guidelines for construction and equipment of hospital and medical facilities" [1] In isolation ward for prevention of airborne transmission, the air supply volume ! 12 h −1 and the fresh air volume ! 2 h −1 . In the bathroom, laundry, waste disposal room, disinfection room, anteroom of isolation ward, the exhaust air volume ! 10 h −1 ASHRAE 170-2013 "Ventilation of Health Care Facilities" In new-built isolation ward for prevention of airborne transmission, the air change rate ! 12 h −1 and the outdoor air volume ! 2 h −1 . In the antechamber, the air change rate for exhaust air ! 10 h −1 Australia "Guidelines for the classification and design of isolation rooms in health care facilities" [1] In negative pressure isolation ward, the flow rate of dilution air should be the larger value between 12 h −1 and 522 m 3 /h USA "Guidelines on the design and operation of HVAC systems in disease isolation areas" [1] In newly-built isolation ward, disposal room and mortuary, the flow rate of dilution air ! 12 h −1 . In the bathroom, the exhaust air volume ! 10 h −1 . In the consulting room for infectious patient, the flow rate of dilution air ! 15 h −1 and the fresh air volume ! 2 h −1 "Guideline for Design and Operation of Hospital HVAC Systems" (HEAS-02-2004) established by Healthcare Engineering Association of Japan In isolation ward, the total volume should of exhaust air be 12 h −1 in the isolation ward disperses in the whole room. Therefore, it is difficult to provide the requirement in the isolation ward. Moreover, the bacterial generation rate cannot be determined based on one kind of disease. In this chapter, one thought to calculate the air change rate in the negative pressure isolation ward will be proposed in a comprehensive way. In terms of air cleaning handling, the circulation air system is shown in Fig. 5 .1. In the figure, N t is the indoor particle concentration at time t, pc/L; N is the stable particle concentration indoors, pc/L; N 0 is the initial particle concentration indoors, which is the particle concentration at time 0, pc/L; V is the volume of the cleanroom, m 3 ; N is the air change rate, h −1 ; G is the particle generation rate per unit volume indoors, pc/(m 3 min); M is the concentration of atmospheric dust, pc/L; S is the ratio of the return air volume to the supply air volume. When the purpose is to remove bioaerosols from indoor air, the implications of η in the figure are: η 1 is the efficiency of the coarse filter (or the combination of air filter for the outdoor air) for bioaerosol (the particle counting efficiency, which is expressed with decimal); η 2 is the efficiency of the middle filter for bioaerosol; η 3 is the efficiency of the final filter for bioaerosol. Under the steady-state condition, the calculation equation for the indoor bacterial concentration is: When there is no specific bioaerosol from the supply air into the isolation ward, M = 0. When HEPA filter is installed on the return air grille or the air supply outlet, or both, the efficiency for bioaerosol reaches more than 99.999%. Equation (5.1) can be simplified as: For the full fresh air system, there is only supplied air and exhausted air. The flow rate of exhausted air is larger than that of the supplied air. The schematic diagram is shown in Fig. 5 .2. Because s = 0, we obtain With the same method, Eqs. (5.2) and (5.3) can be also simplified. This means that no matter what kind of the system is, as long as there is no such kind of dust source or bacterial source in the atmosphere and HEPA filters are installed for the exhausted air or the return air, the equation to calculate the air change rate is the same. 3), two parameters must be known for calculating the air change rate, which are the bacterial generation rate indoors and the standard for the bacterial concentration. In Eqs. , the value of G should be determined at first. G is the bacterial generation rate per unit volume. The bacterial generation rate per unit time should be known, so that under the assumption of the uniform distribution, the bacterial generation rate per unit volume indoors G could be obtained. Then after considering the non-uniform distribution, the air change rate n can be obtained with the non-uniform distribution coefficient W. As mentioned before, it is not comprehensive to use the data on the bacterial generation rate for individual disease which occurred occasionally. Based on the analysis on foreign literates [2] , we could obtain the following information. 1. When people wear the asepsis clothes, the bacterial generation rate in the static state is 100-300 pc/(min people). When the common activity is carried out on body, the bacterial generation rate is 150-1000 pc/(min people). When people walk fast, the bacterial generation rate is 600-2500 pc/(min people). 2. When people wear the ordinary cloth, the bacterial generation rate is 300-62000 pc/(min people). 3. During the coughing process for once time, the bacterial generation rate is 70-700 pc/(min people). During the sneezing process for once time, the bacterial generation rate is 4000-60000 pc/(min people), which is slightly different from that in Fig. 1 .3. 4. The ratio of the bacterial generation rate between the condition when people wear mask and that without mask is 1:7-1:14. 5. The ratio of the bacterial generation rate to the particle generation rate is 1:500-1:1000. In previous section, the bacterial generation rates during coughing and sneezing processes are given. But the information on bioaerosol size is not given. The frequency of sneezing per hour is unknown. The data in detail was given in Fig. 1 .3. When people sneeze for once time, the generation rate of aerosol with diameter 10 lm is 3 Â 10 5 pc, which is larger than the value given in the previous section. The generation rates of aerosol with diameter 1 and 0.3 lm are 2 Â 10 4 pc and 10 pc, respectively. When people cough for once time, the generation rates of aerosol with diameter 10, 1 and 0.3 lm are 1. 5 Â 10 3 pc, 30 pc and 1 pc, respectively. However, the droplets generated during coughing and sneezing processes will evaporate quickly. The evaporation rate is related to the temperature, the vapor pressure of the droplet and the atmospheric pressure. The evaporation time of the droplet can be obtained with the following equation [3] : ð5:5Þ According to the calculation performed by Chen [4] , the following values can be chosen for various parameters of water droplet. t is the time, s; D p is the diameter of the droplet, which is 9.53 Â 10 −4 cm; R is the gas constant, which is 8.317 Â 10 7 erg/(mol K); T is the absolute temperature, which is 293 K (i.e., 20°C); q L is the density of the liquid, which is 1 g/cm 3 for is the kinematic viscosity, cm 2 /s; M 1 is the molecular mass of the liquid vapor, which is 18 g/mol for H 2 O; d is the degree of saturation, which is 0.3 (this means the relative humidity is 30%); P 1 is the vapor pressure of the droplet (here it is the differential pressure of the water vapor), which is 5.6 Â 1.33 Â 10 3 dyn/cm 2 ; P is the vapor pressure of the droplet, which is 5.6 Â 1.33 Â 10 3 dyn/cm 2 ; D 1 is the dispersion coefficient of the liquid vapor through the gas, which is 0.252 cm 2 /s; k is the average mean free path of the molecular, which is 6.53 Â 10 −6 cm. For the water droplet with diameter 9.5 lm, it can be completely evaporated in 0.104 s. When the relative humidity is 60%, it only takes 0.193 s to evaporate completely. According to the calculated results by foreign scholars, under the condition of relative humidity 70%, the water droplet with diameter 5 lm will evaporate in 0.029 s [5] , which is much faster than the above result. On contrary to the water, the salive is the secretion from the parotid gland, the submandibular gland, the sublingual gland and the minor salivary glands. According to the analysis by Kou, water component occupies more than 99% of the salive. The solid component accounts for about 0.7%, where the organic compound and the inorganic compound occupy 05 and 0.2%, respectively [6] . Moreover, 0.85% of the body fluid is NaCl on average, which is also the standard value for the normal saline. Therefore, the maximum ratio of the NaCl in the salive is the level of the body liquid. During the evaporation process, the droplet of the salive will be concentrated gradually until the phase change process occurs. In this case, the values of various parameters are not the same as that of the water droplet. Therefore, the time for evaporation will be prolonged. As we know, the test aerosol used for HEPA filter and medical mask is the sprayed NaCl, which is generated from the NaCl solution with concentrate 2%. According to British test standard [7] , Chinese literature [8] and the test standard for HEPA filter in China, the time of evaporation for sprayed NaCl droplet is 2 s. Another problem is that the salive containing the salt component cannot evaporate to vanish completely as the water. The solute will stay airborne as the small salt particle. This means even when the salive droplet will evaporate thoroughly, it will become the extremely small particle. When the salive contains the bacteria, the particle with similar size of the bacteria will be left. Because of the dehydration, bacteria will move and evaporate with the water molecular, which will change the property of the protein in the bacteria and may cause the death of the bacteria. Table 5 .2 shows the recovery rate of the bacteria during the spraying process of droplet [9] . It is shown that the recovery rate of water during the spraying process is the maximum. The solute particle left after evaporation of droplet may be larger than the size of the bacteria it contains, or may be smaller than the size of the bacteria. Suppose both the droplet and the solute particles are spherical, the relationship between their sizes can be expressed as follows [3] , Where d P is the diameter of the solute particle, lm; d D is the diameter of the droplet, lm; c is the percentage for the mass of the solute in the liquid droplet, which is set 0.85%; q P is the density of the solute particle, which is 2.164 g/cm 3 for NaCl; q D is the density of the liquid droplet, which could be approximated as the density of water 1 g/cm 3 since the value of c is extremely small. Therefore, the size of the pure solute particle can be calculated as follows. For the droplet with diameter 10 lm, its smallest size is not smaller than 1.6 lm after 2 s of evaporation. For the droplet with diameter 5 lm, its smallest size is not smaller than 0.8 lm after 2 s of evaporation. For the droplet with diameter 1 lm, its smallest size is not smaller than 0.16 lm after 2 s of evaporation. For the droplet with diameter 0.5 lm, its smallest size is not smaller than 0.08 lm after 2 s of evaporation. By preliminary investigation, it is found that coughing will easily occur in the evening and in the morning when people get cold. In the morning, the average frequency of coughing is one time per 2 s. After getting up in the morning, it is five times per hour. When the maximum bacterial generation rate per hour is calculated based on this data (the frequency per hour is not always such large), the result will have a quite large deviation. After 2 s of evaporation, we obtain: For the size 1.6 lm, It is known that the percentage for the mass of NaCl in the sprayed droplet is 0.85%, and the main diameter of the droplets is 5 lm, the diameter of the solute particles after complete evaporation can be calculated as follows: This diameter value is close to that of the Bacillus subtilis as shown in Fig. 3 .21. For obtaining the air change rate, the standard for the allowable bacterial concentration indoors must be known. But for different diseases, the pathogenic concentrations are obviously different. And for patients and medical personnel, the concentrations are also different. Therefore, it is difficult to set the standard for the pathogenic dosage of indoor air with specific disease or microbes. Take the animal experiment as an example, when experiment with streptococcus and influenza virus as test aerosol on rabbit, results can be obtained as shown in Table 5 .3 [10] . In our opinion, the influence of the pathogenic microbes generated during speaking and coughing process from patient on the patient himself should not be considered. This is why several patients with pulmonary tuberculosis can live in the same room. Therefore, it is of first priority to consider the influence on the medical personnel. Fundamental protective measures are provided for the medical personnel entering into the isolation ward. The main measures are wearing N95 masks. In the early of May in 2003 during the epidemic of SARS, according to the TV report at Hong Kong, there were no people infected in a hospital where all the medical personnel wore N95 masks. However, for these hospitals where the ordinary masks were worn, many medical personnel were infected. The filtration efficiency of N95 mask for particles with diameter 0.075 lm reached more than 95%, which will be introduced in detail later. From Table 5 .4 [11] , the efficiency of the mask made of polypropylene fibrous media for particles with diameter 0.075 lm (which is close to 0.08 lm in the table) under the filtration velocity 13.4 cm/s is the lowest. It is safe when this value is set as the standard. NIOSH standard 42CRF84 has pointed out that the N95 mask meets the standard requirement for mask to prevent the solid tuberculosis bacteria. N95 means the efficiency with the sodium flame method for particles with diameter 0.075 lm is 95%, which meets the standard requirement for N-type. In China, it was misunderstood in some literatures that N95 means the efficiency for DOP with diameter 0.3 lm is 95%. Moreover, there are also requirements for R-type mask with oil aerosol and P-type mask with both solid and liquid aerosol (they are based on the DOP efficiency). After the epidemic of SARS, the standard GB2626 "Respiratory protective equipment. Non-powered air-purifying particle respirator" was revised. There are two types including KN-type and KP-type, which correspond with N-type and P-type in U.S.A. Detailed information is shown in Table 5 .5. The test conditions in Chinese standard are the same as that in U.S.A. The concentration of NaCl is 2% with the median diameter 0.075 lm ± 0.02 lm. The flow rate is 85 ± 4 L/min. There is no requirement for the size of the mask, but it is usually 100 cm 2 . The corresponding filtration velocity is 14.17 cm/s. Therefore, there are two aspects to consider the standard value of the bacteria indoors. One is from the medical personnel. The other is from the environment. (1) Standard for droplet nuclei with diameter 0.075 lm According to the previous section, the filtration velocity can be calculated based on the flow rate and the size of the mask, which is 14.17 cm/s. The corresponding maximum penetration particulate size is equivalent with 0.075 lm. This means that the particle size 0.075 lm corresponds to the minimum efficiency under the filtration velocity 14.17 cm/s. Therefore, test aerosol with diameter 0.075 lm and the filtration velocity 14.17 cm/s are the most unfavorable conditions. When the efficiency under the most unfavorable conditions is met, the requirement under other conditions can be easily satisfied. As mentioned before, there were no one infected when they wore N95 masks. From the aspect of most stringent requirement, there was no bioaerosol inhaled. If even one particle with diameter 0.075 lm was inhaled, there is no possibility for other droplet nuclei to be inhaled (since the efficiency with other particles is higher than that with 0.075 lm). When the medical personnel enter into the ward, it usually takes less than 0.5 h. When special treatment is needed, it may take more than 1 h. In this case, it can be assumed 1.5 h. According to Chinese standard on medical masks, the requirement for the efficiency 95% is under the flow rate 85L/min. We know that the common respiratory flow rate is between 8L/min and 80L/min. It is a much safer consideration for the standard to set such flow rate. When the flow rate of respiratory air is 85L/min, in the inhaled air within 1.5 h, the concentration of particles with diameter 0.075 lm will not be larger than 1/(90 Â 85) = 1.3 Â 10 −4 pc/L. Therefore, when the efficiency of mask reaches 95%, the concentration of particles with diameter 0.075 lm should not exceed 2.6 Â 10 −4 pc/L. (2) Standard for droplet nuclei with diameter 0.075 lm From Fig. 1.3 , it is known that the number of airborne droplet with diameter 10 lm is the most. From the Sect. 5.3.2, the diameter of the airborne nuclei is 1.6 lm. The concentration of particles with diameter 1.6 lm in the inhaled air should not exceed 1.3 Â 10 −4 pc/L. When the N95 mask is worn, the efficiency for 1.6 lm is larger than that for 0.075 lm by three orders of magnitude. Suppose the efficiency is 99.998% (please refer to Chap. 3), the concentration of particles with diameter 1.6 lm in the inhaled air should not exceed 6.5pc/L. (3) Standard for ordinary microbes indoors When particles are captured by masks, the microbial particles are filtered. For the isolation ward where air is supplied through HEPA filter, the particle concentration is based on the diameter ! 0.5 lm. From Table 5 .4, the efficiency of N95 mask for particles with diameter 0.3 lm can be 99.12%. So the calculated efficiency for diameter ! 0.5 lm is 99.97% [12] . The concentration of particles with diameter ! 0.5 lm in the inhaled air should not exceed 1.3 Â 10 −4 pc/L. So the concentration of particles with diameter ! 0.5 lm indoors should not exceed 0.433pc/L. From the environment, there should be no bioaerosol released from the isolation ward. For Three-Room-One-Buffer scheme, i.e., the ward-buffer-exterior or corridor, the final bacterial concentration, i.e., the inhaled bacteria during occupancy period which enters into the exterior room should be less than 1pc. The period for passing through the exterior room is short. There is ventilation in the exterior room. The decayed concentration in 1 min will be more than a half. So the concentration within the first 1 min is considered. When the flow rate of respiratory air is 85 L/min, in the inhaled air within 1.5 h, the concentration of particles with diameter 0.075 lm will not be larger than 0.012 pc/L, so that the total number of inhaled bacteria can be less than 1. When the volume of the exterior room is 25 m 3 (the less the volume is, the more stringent the bacterial concentration in the ward should be), the allowable bacterial number in the exterior room should not exceed 0.012 Â 25 Â 10 3 = 300 pc. In this case, the leakage flow rate into the exterior room during the opening of the door in the buffer room for once time is 1.62 m 3 (please refer to the chapter about the buffer room), where the number of the microbes should not be larger than 300 pc. Given b 3Á1 = 40, the bacterial concentration in the isolation ward should be 300/1620 Â 40 = 7.4 pc/L. (When the volume of the exterior room is 250 m 3 , the allowable concentration can be 74 pc/L). Nuclei with Diameter 0.075 µm With the assumption of uniform distribution, it can be calculated with Eq. (5.3) , i.e., Where G is the generation rate of particles with diameter 0.08 lm (it is equivalent to 0.075 lm) which are obtained after evaporation from the droplet with diameter 0.5 lm. From the previous section, it is 0.12 pc/(m 3 min). N is the allowable concentration of particles with diameter 0.075 lm indoors. From the previous section, it is 2.6 Â 10 −3 pc/L Therefore, under the condition of uniform distribution, we obtain the air change rate: According to the non-uniform distribution theory, when the air change rate n = 3 h −1 , the non-uniform distribution coefficient w can be 4 [13] . So with the non-uniform distribution, n v = 4n = 4Â2.8 = 11.2 h −1 . This means the air change rate should be 11.2 h −1 at least. Nuclei with Diameter from 10 µm to 1.6 µm After Evaporation Suppose the generation rate of particles G with diameter 0.08 lm is 863 pc/(m 3 min), and N = 6.5 pc/L, the air change rate with uniform distribution assumption is n ¼ 60Â863Â10 À3 According to the non-uniform distribution theory, when the air change rate n = 8 h −1 , the non-uniform distribution coefficient w can be 1.5 [13] . So with the non-uniform distribution, n v = wn = 1.5 Â 8=12 h −1 . This means the air change rate should be 12 h −1 at least. According to Sect. 5.3.1, when aseptic cloth (the cloth on patient should be washed and disinfected) is worn and ordinary activity is performed, the maximum the generation rate of particles G is 1000 pc/(minÁpeople). We obtain Based on the aforementioned data, N = 0.433 pc/L. According to the uniform distribution, the air change rate is: With the same method based on the non-uniform distribution theory, the non-uniform distribution coefficient w can be 2.25 according to the literature [13] . So with the non-uniform distribution, n v = wn = 2.25 Â 5.5 = 12.4 h −1 . This means the air change rate should be 12.4 h −1 at least. The largest value of the above three generation rates of particles G is 863 pc/ (m 3 min). N = 7.4 pc/L. According to the uniform distribution, the air change rate is: With the same method based on the non-uniform distribution theory, the non-uniform distribution coefficient w can be 1.75 according to the literature [13] . So with the non-uniform distribution, n v = wn = 1.75 Â 7=12.2 h −1 . This means the air change rate should be 12.2 h −1 at least. Based on the calculation results of the air change rate based on the above four standards, we obtain: Based on the least droplet nuclei with diameter 0.075 lm, the calculated air change rate is 11.2 h −1 ; Based on the most liquid droplets with diameter 10 lm, the calculated air change rate is 12 h −1 ; Based on the common indoor microbes, the calculated air change rate is 12.4 h −1 ; Based on the environmental protection outside of the isolation ward, the calculated air change rate is 12.2 h −1 . The air change rate under these four conditions is between 11 and 12 h −1 . This provides many rational understanding for the recommended valued in foreign standards shown in Table 5 .1. This also provides the basis for the foreign standards. Since the conditions during calculation are relatively stringent, and the requirement for the indoor average concentration of the isolation ward is not so important as that for protecting the medical personnel, it is reasonable to choose 8-12 h −1 . For the isolation ward containing patients with seriously diseases, the relative large value can be adopted. On the contrary, the relative small value can be chosen. By the aforementioned analysis, the requirement can be satisfied when the air change rate is 10 h −1 . However, it is small if the lower limit is set 6 h −1 . In the air change rate, the outdoor air volume can be 3-4 h −1 , which is larger than that under the normal condition. "Guideline for Design and Operation of Hospital HVAC Systems" (HEAS-02-2004) established by Healthcare Engineering Association of Japan has pointed out that the outdoor air volume needed for the isolation ward should be larger than the average outdoor air volume, because the outdoor air needed for the sick people is much larger than that for the healthy people. Multi-application isolation ward and its air conditioning technique without condensed water Design of Cleanroom Handbook on Aerosols Experimental Study on the Testing Apparatus with the Sodium Flame Method on HEPA Filter Modern Air Microbiology (People's Military Medical Press Basic Clinical Laboratory Science (People's Medical Publishing House Method for Sodium Flame Test for Air Filters Test Apparatus of HEPA Filter with the Sodium Flame Method Modern Air Microbiology (People's Military Medical Press Modern Air Microbiology (People's Military Medical Press Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms