key: cord-0032536-idvotsyz authors: Abughrin, Suad E.; Alshana, Usama; Bakirdere, Sezgin title: Magnetic Nanoparticle-Based Dispersive Solid-Phase Microextraction of Three UV Blockers Prior to Their Determination by HPLC-DAD date: 2022-05-16 journal: Int J Environ Res Public Health DOI: 10.3390/ijerph19106037 sha: 5af12b5404572fcff1fe2afb0ef60bcf6c8b716a doc_id: 32536 cord_uid: idvotsyz The need for proper handling of environmental samples is significant, owing to their environmental effects on both humans and animals, as well as their immediate surroundings. In the current study, magnetic nanoparticle-based dispersive solid-phase microextraction was combined with high-performance liquid chromatography using a diode array as the detector (HPLC-DAD) for both the separation and determination of three different UV blockers, namely octocrylene, ethylhexyl methoxycinnamate, and avobenzone. The optimum conditions for the extraction were found to be as follows: Stearic acid magnetic nanoparticles (20 mg) as the sorbent, acetonitrile (100 µL) as the eluent, as well as a sample pH of 2.50, adsorption and desorption time of 1.0 min, with a 3.0 mL sample volume. The limits of detection were as low as 0.05 µg mL(−1). The coefficient of determination (R(2)) was above 0.9950, while the percentages of relative recoveries (%RR) were between 81.2 and 112% for the three UV blockers from the environmental water samples and sunscreen products. The increase in industrial developments globally has resulted in a rapid decrease in the stratospheric ozone by a magnitude of 1% yearly, leading to a reduction in the capacity of the ozone layer to absorb and isolate solar ultraviolet (UV) radiation [1] . Long-term exposure to this radiation causes substantial harmful effects on the human skin. These concerns have raised awareness of the need for sun protection, leading to the popularity of sunscreen products, which are widely recommended by dermatologists for preventing skin damage caused by UV radiation [2] . However, the active ingredients in these sunscreen products, popularly known as UV blockers, have been shown to have several dermatological complications such as dermatitis and allergies, prompting regulatory restrictions to be placed on the maximum permissible concentration that can be used in sunscreen products [3] . The major regulatory agencies, such as the United States (US) Food and Drug Administration (FDA), the European Union (EU) Cosmetics Directive (CD), and Japanese legislation, allow a maximum of 10% of organic UV blockers to be used in cosmetics [4] . Even though these analytes are present in high concentrations in sunscreen products, an efficient sample cleanup step is critical to reduce the matrix effect and preserve column life due to the highly oily nature of such samples. Moreover, there are no official analytical methods dedicated to the determination of UV blockers in sunscreen products [5] . As a improved with these modifications, the combination with other microextraction techniques increases the sample preparation steps that can increase the probability of error as well as the overall analysis time. In this regard, stearic-acid-modified magnetic solid-phase microextraction (SA-MDSPME) was used for the first time based on our current knowledge for the extraction and sample cleanup of three UV blockers, i.e., 2-ethylhexyl 2-cyano-3,3-diphenylacrylate (octocrylene, OCT), butyl methoxy dibenzoyl methane (avobenzone, AVO), and ethyl hexyl methoxycinnamate (EMC), from both sunscreen products and environmental water samples (swimming pool, tap, and sea) prior to separation and detection by HPLC-DAD. Influential experimental parameters affecting the performance of the SA-MDSPME-HPLC-DAD method, including the type and amount of the sorbent, sample pH, the type and amount of eluent, sample volume, as well as the adsorption and desorption time were optimized. This study presents the use of a cost-effective, easy, eco-friendly, and fast method due to the use of a modified MNP as a sorbent, which enabled the elimination of the centrifugation step. All the reagents and chemicals used in the current work were of analytical grade. AVO (logP 4.56, pK a 9.74), OCT (logP 6.78), EMC (logP 5.38), acetic acid, disodium phosphate, HPLC-grade acetonitrile (ACN), ethanol (EtOH), methanol (MeOH), tetrahydrofuran (THF), monosodium phosphate, and sodium acetate were procured from Sigma-Aldrich (Darmstadt, Germany). Trifluoroacetic acid (TFA) was obtained from Fluka (Dresden, Germany). Stearic acid-modified MNPs synthesis and characterization were carried out previously by the group [28] . The preparation of aqueous solutions was performed using deionized (DI) water (18.2 MΩ-cm), obtained with Pure Lab Ultra Analytic (ELGA Lab Water, Lane End, UK). For the calculation of pK a and logP values (i.e., the logarithm of octanol/water partition coefficient), Marvin Sketch (Rev. 20.11.0, ChemAxon Ltd., Boston, MA, USA) was used. The synthesis of stearic acid-coated nanoparticles was carried out according to the method published in the literature, where nanoparticles were coated with different coating materials (Wang et al. 2011; Clare 2016). Briefly, 2.703 g of FeCl 3.6 H 2 O and 1.961 g of (NH 4 ) 2 Fe(SO 4 ) 2.6 H 2 O were dissolved in 100.0 mL of ultrapure deionized water in a flask, heated to 80 • C, and maintained there with constant and vigorous stirring. One milliliter of a concentrated stearic acid solution prepared in ethanol and 10 mL of 25% ammonia solution were added dropwise to the mixture, resulting in a color change from a brick color to a blackish gray color. The reaction was carried out under nitrogen gas to provide an inert atmosphere for 2.0 h at 80 • C. Stearic-acid-coated MNPs were separated with a neodymium magnet and washed with ethanol and ultrapure water several times to eliminate excess acid and then dried at 50 • C for 24 h [28]. Three separate stock solutions containing 1000 µg mL −1 of AVO, OCT, and EMC were prepared in ACN and stored at −15 • C until required. The mixture of the solutions of these three compounds was prepared by diluting the original stock solution to the desired concentration, with ACN as a working standard solution. The working standard solution was re-diluted for calibration purposes. Chromatographic separation was carried out using an Agilent Technologies 1200 Series (USA) HPLC chromatograph, monitored with an Agilent ChemStation for LC 3D systems (Rev. B.03.01) software equipped with an autosampler, degasser, quaternary pump, thermal column jacket, and DAD, with a reversed-phase column (Zorbax 4.6 mm ID × 150 mm, 5 µm, Agilent Technologies, Waldbronn, Germany), using an isocratic elution consisting of 80/20 (%v/v) MeOH:0.5% TFA in DI water with a 0.9 mL min −1 flow rate. A 40 • C column jacket temperature was set with a 20 µL injection volume. The DAD was set at the maximum absorption wavelength of the analytes (310 nm for OCT and EMC, 360 nm for AVO). Water samples were filtered using vacuum filtration through a 0.45 µm cellulose membrane (Whatman, Dassel, Germany) and 0.2 µm sterile nylon syringe filters (Chromfil, China). A FiveEasy Plus TM pH meter was used for all pH measurements. Vortex mixing was performed by an MS 3 digital vortex (IKA, Staufen, Germany). Centrifugation was carried out with EBA20 Portable Centrifuge C2002 (Hettich, Kirchlengern, Germany). Micropipettes (10-100 µL and 100-1000 µL) were obtained from Sigma-Aldrich (St. Louis, MI, USA). For the weighing of the samples, an electronic balance (Mettler-Toledo, Greifensee, Switzerland) was used. The environmental sample (Swimming pool, tap, and seawater samples) were collected from three different locations in the Turkish Republic of Northern Cyprus (TRNC) in 1.0 L plastic bottles and were stored at room temperature. Double filtration was carried out with 0.45 µm Whatman filter paper and 0.2 µm sterile nylon syringe filters prior to analysis. Sunscreen products were obtained from local stores and pharmacies in Nicosia, TRNC. A 20 mg portion of the sunscreen samples was weighed and dissolved with 1.0 mL of ACN in a 15 mL screw-capped, graduated, polypropylene centrifuge tube by vortex for 4 min and centrifugation for 1 min at 6000 rpm. The solution was diluted 500 times with DI water and taken as the sample solution for the sunscreen. The overall schematic diagram of the proposed MNP-DSPME-HPLC-DAD procedure is shown in (Figure 1 ). A 2.0 mL portion of the sample solution (environmental and sunscreen) was added to a 15 mL screw-capped, graduated, polypropylene centrifuge tube and buffered with 1.0 mL of phosphate buffer solution (pH 2.5). The solutions were transferred into 20.0 mg of preconditioned SA-MNPs as the adsorbent and vortexed for 1 min. An external magnetic field was used to collect the analyte-rich SA-MNPs, and the supernatant was discarded. Regarding the external magnetic field, Reyes-Gallardo et al. [29] reported that this property is essential in magnetic solid-phase extraction since it allows the easy dispersion of MNPs in aqueous or organic media and their simple recovery by applying a magnetic field, usually in the form of an external magnet. Moreover, according to Lu et al. [30] , in biotechnology and biomedicine, magnetic separation can be used as a quick and simple method for the efficient and reliable capture of specific proteins or other biomolecules. Most particles currently used are super paramagnetic, meaning that they can be magnetized with an external magnetic field and immediately dispersed once the magnet is removed. The analyte desorption was performed using 100 µL of ACN as the eluent by vortex for 1 min. The collected solution was diluted two times with DI water, and 20 µL was injected into HPLC. The parameters that are critical to achieving maximum extraction efficiency in SA-MDSPME were optimized, including the type and amount of sorbent, in which three types were used, including SA-MNP, Zirconium nanoparticles (Zr-NP), and multi-walled carbon nanotubes (MW-CNT) ranging from 10-50 mg. Furthermore, the pH of the sample solution was investigated using different buffer solutions ranging from 2.5-6.5, the type and amount of eluent were evaluated using different organic solvents (ACN, Et-OH, MeOH, and THF) with different volumes within the range of 50-400 mL, the adsorption and desorption time were investigated within 0-4.0 min, and the sample volume was investigated by varying the volume from 2-6 mL. The influence of each parameter on the method's extraction efficiency was studied by changing a single parameter at a time while keeping the remaining parameters constant. The absolute percentage recovery (%R) was used to determine the efficiency of the extraction. A critical parameter for the extraction and preconcentration of the target analyte is the selection of the appropriate sorbent. The impact of the type of sorbent on the recovery was evaluated using three different sorbents, SA-MNP, Zr-NP, and MW-CNT. The highest recovery was observed using SA-MNP (Figure 2A ), which could be due to the combined effect of the modification of the magnetic nanoparticles with the stearic acid functional group that can increase the preconcentration and selectivity of the adsorbent to the analytes [28] and the magnetic property of the sorbent that permits easy separation of the sorbent from the sample solution using an external magnetic field in contrast to their non-magnetic alternatives used in the study, thereby eliminating the centrifugation step in addition to preventing any blockage from occurring in the HPLC capillary tubes and column. Generally, the analyte preconcentration is influenced by the amount of sorbent material used. To investigate the effect of the amount of SA-MNPs on the recovery of OCT, AVO, and EMC, various amounts of sorbent ranging from 10-50 mg were applied. The average recovery increased linearly with an increase in the amount of sorbent from 10 to 20 mg due to an increase in the sorbent's surface area. Therefore, it resulted in more interaction between the analytes and SA-MNP. However, the recovery decreased and remained stable in the range of 30 to 50 mg due to the insufficient volume of ACN (100 µL) to elute the retained analytes in sorbent ( Figure 2B ). Therefore, 20 mg of SA-MNP was used as the optimum amount of sorbent. Sample pH is considered significant in terms of extraction efficiency and recovery owing to its impact on the affinity of coated nanoparticles with the analyte [31] . pH levels in the range of 2.5-6.5 were evaluated for the recovery of the analytes. This was achieved by using different buffer solutions (phosphate and acetate). At a higher pH, the analytes can be hydrolyzed, leading to a decrease in the extraction efficiency and, hence, low recovery [22, 24] . The highest recovery was obtained at pH 2.5 ( Figure 2C ) and was used for all analyses. A suitable eluent that can desorb the analyte from the surface of the sorbent is desired. For this reason, ACN, EtOH, MeOH, and THF were selected for this study. For the three UV blockers examined, ACN gave the highest recovery ( Figure 2D ) and was used for the rest of the experiments. The volume of ACN as the eluent was investigated within the range of 50-400 µL. The results demonstrated that the highest %R of the analytes were observed with 100 µL of ACN before decreasing, which could be a result of the dilution of the analyte due to the excess volume of ACN ( Figure 2E ). However, the minimal volume of eluent (below 100 µL) would not be enough for elution of all the analytes and may lead to low recovery of the analytes. Therefore, 100 µL of ACN was taken as the optimum volume of the eluent. types were used, including SA-MNP, Zirconium nanoparticles (Zr-NP), and multi-walled carbon nanotubes (MW-CNT) ranging from 10-50 mg. Furthermore, the pH of the sample solution was investigated using different buffer solutions ranging from 2.5-6.5, the type and amount of eluent were evaluated using different organic solvents (ACN, Et-OH, MeOH, and THF) with different volumes within the range of 50-400 mL, the adsorption and desorption time were investigated within 0-4.0 min, and the sample volume was investigated by varying the volume from 2-6 mL. The influence of each parameter on the method's extraction efficiency was studied by changing a single parameter at a time while keeping the remaining parameters constant. The absolute percentage recovery (%R) was used to determine the efficiency of the extraction. A critical parameter for the extraction and preconcentration of the target analyte is the selection of the appropriate sorbent. The impact of the type of sorbent on the recovery was evaluated using three different sorbents, SA-MNP, Zr-NP, and MW-CNT. The highest recovery was observed using SA-MNP (Figure 2A) , which could be due to the combined effect of the modification of the magnetic nanoparticles with the stearic acid functional group that can increase the preconcentration and selectivity of the adsorbent to the analytes [28] and the magnetic property of the sorbent that permits easy separation of the sorbent from the sample solution using an external magnetic field in contrast to their non-magnetic alternatives used in the study, thereby eliminating the centrifugation step in addition to preventing any blockage from occurring in the HPLC capillary tubes and column. Generally, the analyte preconcentration is influenced by the amount of sorbent material used. To investigate the effect of the amount of SA-MNPs on the recovery of OCT, AVO, and EMC, various amounts of sorbent ranging from 10-50 mg were applied. The average recovery increased linearly with an increase in the amount of sorbent from 10 to To achieve a high degree of interaction between the sample solution and the sorbent, the adsorption time was considered as the time period between the addition of the sample solution to the SA-MNP sorbent and the moment just before detection, which corresponds to the time of vortexing. The effect of the duration of the adsorption was investigated with a vortex time of 0-4.0 min. It was observed that applying 10 s of manual shaking prior to vortexing was insufficient for the distribution of particles throughout the sample, hence a minimum vortex time of 1.0 min will accelerate the contact between the analytes and the sorbent, leading to an increase in recovery. A further increase in the contact time did not affect recovery, signaling that equilibrium was achieved at 1.0 min ( Figure 2F) . Therefore, the optimum adsorption time was selected as 1.0 min. To study the impact of the desorption time on analyte recoveries, the vortex time was applied once again between 0 and 4 min as shown in Figure 2 . There was an increase in the recovery from 0 min (without vortex) to 1.0 min; the recovery increased due to agitation of the analytes by vortex to transfer them from the sorbent into the eluent. However, the trend remained unchanged from 1.0 min to 4.0 min. Hence, 1.0 min was considered the optimum desorption time to elute the analytes. The influence of the sample volume on the recovery of analytes was investigated by varying the volume from 2.0-6.0 mL, while the concentration of the analyte was maintained at 1.0 µg mL −1 (see Figure 2H ). This shows that the recoveries of three analytes increased up to 3.0 mL, after which they declined, likely due to the maximum sorbent capacity of 20 mg with the sample volume of 3.0 mL. Subsequently, 3.0 mL was employed as the maximum sample volume. An aqueous calibration graph was used to assess the performance of the proposed method by preparing a standard solution of UV blockers between the range of 0.0 to 15.0 µg mL −1 without microextraction prior to separation and detection by HPLC-DAD. Furthermore, the environmental samples were spiked with a standard solution of UVblockers between 0.0 and 6.5 µg mL −1 , while the sunscreen products were spiked between 0.0-5.5 µg mL −1 before applying the optimized MNPs-DSPME-HPLC-DAD procedure to plot the standard addition calibration graphs. From the results shown in Table 1 , calibration curves with a determination coefficient (R 2 ) between 0.9952 and 0.9996 were observed, as well as detection limits (LOD) within 0.31 to 0.43 µg mL −1 for the aqueous standard, 0.07 to 0.18 µg mL −1 for the environmental samples, and 0.05 to 0.14 µg mL −1 for the sunscreen products, which were determined by applying equation 3 (S b /m), whereby m is considered the slope while S b is the standard deviation of the regression equation. The limit of quantitation (LOQ), calculated based on equation 10 S b /m, was within the range of 1.03 to 1.43 µg mL −1 for the aqueous standard, 0.22 to 0.61 µg mL −1 for the environmental samples, and 0.16 to 0.48 µg mL −1 for the sunscreen products. A linear response was attained from LOQ to 15 µg mL −1 for the aqueous calibration graph, LOQ to 6.5 µg mL −1 for the environmental samples, and LOQ to 5.5 µg mL −1 for the sunscreen products. The method's precision was assessed using percentage relative standard deviation (%RSD) with intraday precision between 3.05 and 3.72% for the aqueous standard, 2.34 and 6.90% for environmental samples, and 1.12 and 3.68% for the sunscreen products. The interday precision was between 5.05 and 6.65% for the aqueous standard, 3.83 and 13.21% for environmental samples, and 2.53 and 8.74% for the sunscreen products. To be able to evaluate the possible matrix effect, an addition-recovery study was carried out by spiking environmental and sunscreen samples with standards of UV-blockers at three levels of concentration (0.5, 3.5, and 5.0 µg mL −1 for environmental samples and 1.5, 3.5, and 4.5 µg mL −1 for sunscreen samples) and applying the proposed SA-MDSPME-HPLC-DAD method. The percentage of relative recovery (%RR) was found to be between 81.2 and 112 (see Table 2 ). After a comparison between different slopes of the calibration curves, statistical analysis using ANOVA was applied to evaluate the effects of the matrix (see Table 2 ). A statistical difference was observed (p < 0.05), which was an indication of the effect of the matrix, making it necessary to apply the standard-addition method to be able to eradicate it. The sunscreen samples were found to contain the UV blockers stated in the label, with sunscreen 1 containing EMC at a concentration of 3.3%, w/w, sunscreen 2 containing AVO at a concentration of 6.4%, w/w, and finally, sunscreen 3 containing OCT and AVO at a concentration of 4.6 and 4.3%, w/w, respectively. The analytes were undetected in the environmental samples, likely due to the samples being collected during the COVID-19 pandemic when outdoor activities were limited. The proposed SA-MDSPME-HPLC-DAD method was compared with similar studies in the literature for the determination of UV blockers in sunscreen products and environmental samples in terms of analysis time, the volume of organic solvent, detection limit, and precision based on the percentage of relative standard deviation. The proposed study showed superior performance compared to those in the literature for the determination of the analytes in sunscreen products by requiring the least analysis time and the least volume of organic solvent, except for [6] , which required only 2 min. On the other hand, the sensitivity (LOD) was similar to other methods found in the literature (see Table 3 ). Comparing the current proposed study for the determination of environmental water samples with other recent studies conducted in the literature, a lower consumption of the organic solvent, as well as a shorter analysis time, was observed. In terms of sensitivity, the techniques in the literature exhibited better sensitivity, although the analytes could not also be detected or quantified in the environmental samples for those techniques except for in [32] . This is because the analytes are present in very low concentrations in environmental samples; therefore, strong sensitive analytical instruments are required. DSPME-HPLC-DAD 6 1.1 0.05-0.14 6.1-9.5 This study a TF-SPME-HPLC-UV: Thin-film solid-phase microextraction-high-performance liquid chromatographyultraviolet/visible detection. CPE-D-µ-SPE-LC-DAD: Cloud point-dispersive micro-solid phase extraction-liquid chromatography-diode array detection. DLLME-HPLC-UV: Dispersive liquid-liquid microextraction-highperformance liquid chromatography-ultraviolet/visible detection. LOV-BI-LC: Lab on valve-bead injectionliquid chromatography. DµSPE-LC-UV/Vis: Dispersive micro solid-phase extraction-liquid chromatographultraviolet/visible detection. HPLC-UV/Vis: High-performance liquid chromatography-ultraviolet/visible detection; HPLC-DAD: High-performance liquid chromatography-diode array detection; LC-UV/Vis: Reversedphase-liquid chromatography-ultraviolet/visible detection; b Total volume of organic solvent consumed per sample. c Limit of detection. d Percentage relative standard deviation. In the current work, SA-MDSPME was used for the extraction of UV blockers and sample cleanup of environmental samples and sunscreen products prior to separation and detection by HPLC-DAD. The method decreased the use of organic solvents substantially in addition to fast sample preparation due to the use of magnetic nanoparticles. This can simplify the microextraction step and decrease the energy consumption by replacing the centrifugation step with a magnetic field for the separation of the sorbent from the sample solution and eluting the analyte, which agrees with green chemistry protocols. In addition, the microextraction served as a sample cleanup, which is especially important when oily samples are analyzed to protect and increase the lifetime of the column. The analyte could be detected in genuine sunscreen samples and could serve as a useful alternative for these kinds of analyses. The findings of the current study showed that the optimum conditions for the extraction step were found to be as follows: SA-MNPs (20 mg) as the sorbent, ACN (100 µL) as the eluent, along with a sample pH of 2.50, adsorption and desorption times of 1.0 min, with a 3.0 mL sample volume. The LOD was as low as 0.05 µg mL −1 . The coefficient of determination (R 2 ) was above 0.9950, while the percentage of relative recoveries (%RR) was within 81.2-112% for the three UV blockers from the environmental water samples and sunscreen products. Avobenzone encapsulated in modified dextrin for improved UV protection and reduced skin penetration Changes in ultraviolet absorption of sunscreens after ultraviolet irradiation Contact and photocontact sensitivity to sunscreens-Review of a 15-year experience and of the literature UV filters: From sunscreens to human body and the environment Sunscreen analysis-A critical survey on UV filters determination A reliable and environmentally-friendly liquid-chromatographic method for multi-class determination of fat-soluble UV filters in cosmetic products Pharmaceuticals and personal care products in the environment: Agents of subtle change? Environ. Health Perspect Aqueous photolysis of the sunscreen agent octyl-dimethylp-aminobenzoic acid-Formation of disinfection byproducts in chlorinated swimming pool water Current trends on the determination of organic UV filters in environmental water samples based on microextraction techniques-A review A critical review in calibration methods for solid-phase microextraction Multiple solid-phase microextraction Dynamics of organic-compound extraction from water using liquid-coated fused-silica fibers Solid-Phase Microextraction Coupled to High-Performance Liquid-Chromatography Dispersive solid phase microextraction Dispersive solid-phase microextraction method for sample extraction in the analysis of four tetracyclines in water and milk samples by high-performance liquid chromatography with diode-array detection Application of magnetic nanoparticles for magnetic solid-phase extraction in preparing biological, environmental and food samples Introducing a new and rapid microextraction approach based on magnetic ionic liquids: Stir bar dispersive liquid microextraction PAMAM-modified citric acid-coated magnetic nanoparticles as pH sensitive biocompatible carrier against human breast cancer cells An effective and rapid magnetic nanoparticle based dispersive solid phase extraction method for the extraction and preconcentration of cadmium from edible oil samples before ICP OES measurement Molecularly imprinted dispersive solid-phase microextraction for determination of sulfamethazine by capillary electrophoresis A new carbon-based magnetic material for the dispersive solid-phase extraction of UV filters from water samples before liquid chromatography-tandem mass spectrometry analysis Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter determination in water samples Stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticls-nylon 6 composite for the extraction of hydrophilic organic compounds in aqueous media Development of stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticles and its analytical application to the determination of hydrophobic organic compounds in aqueous media Cloud point-dispersive mu-solid phase extraction of hydrophobic organic compounds onto highly hydrophobic core-shell Fe2O3@C magnetic nanoparticles Magnetic retrieval of a switchable hydrophilicity solvent: Fast homogeneous liquid-liquid microextraction for the determination of benzophenone-type UV filters in environmental waters Fast dispersive liquid-liquid microextraction based on magnetic retrieval of in situ formed an ionic liquid for the preconcentration and determination of benzophenone-type UV filters from environmental water samples Simultaneous determination of 4-tert-octylphenol, chlorpyrifos-ethyl and penconazole by GC-MS after sensitive and selective preconcentration with stearic acid coated magnetic nanoparticles Magnetic nanoparticles-nylon 6 composite for the dispersive micro solid phase extraction of selected polycyclic aromatic hydrocarbons from water samples Magnetic nanoparticles: Synthesis, protection, functionalization, and application Determination of indium using vortex assisted solid phase microextraction based on oleic acid coated magnetic nanoparticles combined with slotted quartz tube-flame atomic absorption spectrometry Orthogonal array design for the optimization of ionic liquid-based dispersive liquid-liquid microextraction of benzophenone-type UV filters Novel approach to high-throughput determination of endocrine disruptors using recycled diatomaceous earth as a green sorbent phase for thin-film solid-phase microextraction combined with 96-well plate system On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach Determination of fourteen sunscreen agents in cosmetics using high-performance liquid chromatography Simultaneous Determination of Nine UV Filters and Four Preservatives in Suncare Products by High-Performance Liquid Chromatography Development and application of a HPLC method for eight sunscreen agents in suncare products The authors are thankful to Nusret Ertaş from the Department of Analytical Chemistry, Faculty of Pharmacy at Gazi University, Ankara, Turkey, and Assist. Hürmus Refiker from Department of Analytical Chemistry, Faculty of Pharmacy, Near East University for their valuable recommendations and suggestions. In addition, we are thankful to Mais Al-Nidawi and Jude Caleb for their help and assistance. The authors are equally grateful to both the Libyan Ministry of higher education and Scientific research and Near East University for their substantial support during the process of this research. The authors declare no conflict of interest. Author Contributions: S.E.A.: Conceptualization, methodology, investigation, writing-original draft. U.A.: Conceptualization, methodology, validation, writing-review and editing, supervision. S.B.: Synthesis and characterization of the steric acid magnetic nanoparticles in a previous study, provided the first and second authors with stearic-acid-modified MNPs (SAMNPs) to work on in the current study. All authors have read and agreed to the published version of the manuscript.Funding: This research received no external funding, and The APC was funded by Suad E Abughrin. Not applicable for studies not involving humans or animals. Not applicable for studies not involving humans. The data used in this study will be provided on request.