key: cord-0032152-jtbznvj0 authors: Jeong, Bongjin; Akter, Rashida; Oh, Jeonghyun; Lee, Dong-Gi; Ahn, Chang-Geun; Choi, Jong-Soon; Rahman, Md. Aminur title: Novel electrochemical PMI marker biosensor based on quantum dot dissolution using a double-label strategy date: 2022-05-25 journal: Sci Rep DOI: 10.1038/s41598-022-12444-6 sha: 89223d9c4e42b4c9dd93c5cc5009fa0f0c13f3d2 doc_id: 32152 cord_uid: jtbznvj0 A novel and facile post-mortem interval (PMI) biosensor was fabricated using a double-label strategy to detect the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) biomarker. A monoclonal anti-GAPDH antibody was immobilized on a surface label containing cadmium selenide quantum dots (CdSe QDs) on a cysteamine graphene oxide (Cys-GO) self-assembled monolayer. Glucose oxidase (GOx) was used as a signal label to conjugate with GAPDH. GAPDH recognition was achieved through the dissolution of the surface-attached CdSe QDs by hydrogen peroxide generated through GAPDH-conjugated GOx-catalyzed β-glucose oxidation. To enhance sensitivity, a competitive interaction was introduced between free and conjugated GAPDH to the active site of the anti-GAPDH antibody. The electrochemical response due to CdSe dissolution decreased proportionally with the concentration of free GAPDH. Differential pulsed voltammetry was conducted to determine the analytical characteristics of the immunosensor, including the limit of detection, linear dynamic range, target selectivity, system stability, and applicability toward the analysis of real samples. Fabrication of immunosensor probe. The immunosensor platform was modified by GO-incorporated SAM of cysteamine (Cys) through chemical binding 20 . First, Au electrodes were polished with a 0.05 µm alumina/water slurry on a polishing cloth. Next, the polished electrode was sonicated and rinsed by DI water. Then, the mirror-finished electrode was washed out with a piranha solution (70% H 2 SO 4 and 30% H 2 O 2 ), rinsed completely with DI water, and dried in an oven. The Cys-GO solution was prepared by mixing 36 mM Cys in DI water with 10 µg/mL GO. The final mixture (5 µL) was dropped on the Au electrode and kept for 8 h 21, 22 for self-assembly. The carboxylic acid groups on QDs were activated with 10 mM EDC/NHS solution 23 , and the Au/ Cys-GO-modified surface was covalently bonded with the activated QDs for 10 h (Au/Cys-GO/QD) 24 . After washing, the Au/Cys-GO/QD electrode was incubated in a 0.1 M PBS solution (pH 7.0) containing 1 µg/mL anti-GAPDH for 4 h 25-27. The GAPDH antibody (Ab) was immobilized on the QDs via the amide bonds between the carboxyl group of the QD and the amine group of anti-GAPDH (Au/Cys-GO/QD/anti-GAPDH). After that, the electrode was washed three times using 0.1 M PBS, then placed in 0.05% BSA solution for 1 h to block the non-specific absorption of other proteins. After rinsing three or four times using PBS, the BSA-blocked Au/ Cys-GO/QD/anti-GAPDH immunosensor was stored in the refrigerator at 4 °C. Figure 1 describes the overall fabrication of the GAPDH immunosensor. www.nature.com/scientificreports/ Preparation of GOx/GAPDH conjugates. The GOx/GAPDH conjugates were prepared according to the following procedure 28, 29 . First, 50 µg/mL of GAPDH in 1.0 M PBS and 0.5 mL of 25% glutaraldehyde were mixed at room temperature (RT) for 18 h (glu-GAPDH). Excess glutaraldehyde was filtered by a Sephadex G-25 column in 10 mM tris/1 mM EDTA (pH 7.5) equilibrated with 0.9% NaCl. Then, 3 mL GOx (1.0 mg/mL) in 1 M PBS solution was mixed with 6 mL of glu-GAPDH to induce covalent cross-linking between GOx and glu-GAPDH. The mixture was incubated for 24 h at RT (conjugated GAPDH). In order to prevent the non-specific binding of the remaining active site of the prepared conjugate, blocking was performed using 0.1% (w/v) BSA solution, and dialysis was performed in 0.1 M PBS (pH 7.4). Finally, the conjugate was filtered through a sterile Millipore membrane (0.20 µm) then stored at − 20 °C. SEM, EDS, confocal microscopy, XPS, CV of the immunosensor probe. Figure 2 shows the SEM images of GO-, Cys-GO-, and Cys-GO/QD-modified Au surfaces. The GO electrode exhibited a thick and rugged morphology in the SEM image. For the Cys-GO electrode, a big spot was observed on the smooth SAM surface, confirming that GO was incorporated in Cys. The Cys-GO/QD-modified Au surface showed some offshoots due to QD attachment after QD binding. However, the QDs are small nanoparticles of 5 nm size; thus, they are not visible in the images. EDS was performed to characterize the surface of the Au/Cys-GO/QD electrode (Fig. 2) . The survey spectra of Au/GO and Au/Cys-GO indicated the presence of C, O, S, and K and C, N, O, and S, respectively. However, the Au/Cys-GO/QD electrode was found to possess C, N, O, S and Cd. The presence of Cd on the surface indicated the successful immobilization of the QDs on the immunosensor. www.nature.com/scientificreports/ XPS analysis was performed in order to characterize the covalent bonding of QD with Au/Cys-GO as shown in Fig. S1 . The C1S peak in Au/Cys-GO/QD and the N1S peak in Au/Cys-GO shifted to higher and lower energies, respectively, clearly indicates the formation of the covalent bonding between the carboxylic acid of QD and the amine groups of cysteamine in Au/Cys-GO. Confocal microscopy was conducted to further characterize the GAPDH immunosensor surface. Fig. S2 shows the fluorescence images of Au/Cys and Au/Cys-GO/QD. The fluorescence was evident from the Au/Cys-GO/QD electrode surface owing to QD emission, whereas the Au/Cys electrode did not exhibit any fluorescence. These results confirm that the QDs have been successfully immobilized on the Au/Cys-GO surface. The electrochemical behavior of the Au/Cys-GO/QD electrode was analyzed by CV. Fig. S3 shows the CV profiles of the Au/Cys-, Au/Cys-GO-, and Au/Cys-GO/QD-modified electrodes in PBS. A very small redox peak was observed for the Au/Cys-modified electrode because of the absence of electroactive materials such as nanoparticles for the redox reaction. Moreover, for the Au/Cys-GO-modified electrode, a significantly increased redox peak between −0.1 V and 0.3 V vs. Ag/AgCl was observed, suggesting that the introduction of GO improved the conductivity and increased the maximum current. After Au/Cys-GO/QD modification, the redox peak was located at the same position as that observed for the Au/Cys-GO electrode, with an increment in the peak current. The separation between the reduction and oxidation peaks was calculated as 0.4 V, implying a quasireversible electron transfer reaction. Table S1 shows the increase rate of the redox peak, indicating a gradual increase in current following further steps. Theses analysis results confirmed that Cys-GO/QD was successfully immobilized on the Au electrode surface with an electroactive characteristic and can be used for the fabrication of the GAPDH immunosensor. UV/Vis characteristics of the QD dissolution. The QD dissolution was analyzed by UV/Vis spectroscopy. Fig. S4 shows the UV/Vis spectra obtained for 10 µg/ml QDs, 10 µg/ml QDs reacting with 5% H 2 O 2 for 5 min, and 10 µg/ml QDs reacting with 1% H 2 O 2 for 5 min. As expected, the QDs showed a peak between 440 and 460 nm. After the QDs reacted with H 2 O 2 , the absorbance was remarkably reduced; the high concentration of H 2 O 2 afforded lower absorbance than the low concentration, confirming that the QD dissolution was related to the presence of H 2 O 2 . Optimization. To achieve the best response in real sample analysis, the dilution ratio of the antibody was optimized. Fig. S5 shows the response of the anti-GAPDH antibodies to the detection probes diluted in various ratios from 1:2000 to 1:40 under 1 ng/mL free GAPDH conditions. The current response increased significantly when the Ab dilution factor varied from 1:2000 to 1:200 and did not increase further when the dilution factor was 1:200 or higher. Thus, the optimum anti-GAPDH antibody ratio was finalized as 1:200. The pH and incubation time optimizations are important for maximum sensitivity in antibody-antigen interaction based immunosensor. However, we did not try to optimize the pH and incubation time in this study because our aim was to use this immunosensor at a physiological pH condition (pH=7.0 ~ 7.4). Regarding incubation time of antibody-antigen interaction, previous results on antibody-antigen binding showed 30 min − 2 h time incubations appropriate for maximum responses 25-27. . Considering the fact that most of antibody-antigen interactions are needed to have similar binding time, we did not attempt to optimize it. However, for the maximum antibodyantigen binding, we used 4 h incubation time as the incubation step was performed at 4 ℃. Analytical performance of GAPDH immunosensor. DPV is a more sensitive technique than CV; thus, it was used for the quantification of free GAPDH. Figure 3 shows the DPV responses measured after the dissolution of QDs at various concentrations of free GAPDH ranging between 10 fg/mL and 100 ng/mL. The response www.nature.com/scientificreports/ was measured after incubating the immunosensor in PBS containing conjugated GAPDH and various concentrations of GAPDH for 10 h. As shown in Fig. 3 , a stripping peak at −0.43 V vs. Ag/AgCl was observed owing to the dissolution of Cd to Cd + . Next, the immunosensor was placed with both conjugated GAPDH and free GAPDH in PBS. Free GAPDH competed for binding to the active sites at the anti-GAPDH antibody; thus, the amount of conjugated GAPDH bound to the antibody active sites was reduced and, consequently, the reduction current peak of Cd stripping decreased due to the presence of free GAPDH. Because the bounded GOx interacting with β-glucose in PBS solutions generated H 2 O 2 30 , the enzymatically generated H 2 O 2 could dissolve Cd metal of QDs. Therefore, the Cd stripping peak gradually decreased and its intensity was proportional to the amount of free GAPDH. In order to achieve sensitive GAPDH detection, the analytical performance was carried out under optimized experimental conditions. When the concentration of free GAPDH was increased and the amount of conjugated GAPDH was fixed, a low amount of GOx coupled with the antibody binding sites via the competitive binding strategy 31 , generating a low amount of H 2 O 2 for QD dissolution. As a result, the intensity of the Cd stripping peak did not significantly decrease. The response of stripping current increased upon the decrease in the concentration of free GAPDH in PBS and a direct linear relationship was observed between the current response and free-GAPDH concentration, enabling the quantification of free GAPDH by this dissolution strategy. Figure 4 shows the calibration plot using the stripping-current intensity obtained from Fig. 3 . The linear range of GAPDH detection was determined to be from 10 fg/mL to 100 ng/mL. The linear dependence between the intensity and free-GAPDH concentration produced a regression equation of I (y) = 0.0969 · log x + 0.7769 with a correlation coefficient of 0.9802. The relative standard deviation was approximately 5.16% (n=5) at a GAPDH concentration of 1 ng/mL. Based on three measurements of the standard deviation of the blank noise (95% confidence level, k = 3, n = 5), the limit of detection was determined as 2 fg/mL. All analytical parameters are summarized in Table S2 . The analytical parameters obtained in this study and those of previously reported QD-based biosensors are compared in Table 1 [32] [33] [34] [35] [36] [37] [38] , demonstrating the high sensitivity of the GAPDH sensor developed in this work. Selectivity, stability, and real sample analysis. To investigate the selectivity, the competitive binding of the immunosensor was investigated using conjugated GAPDH and similar biomarkers such as PSA, carcinoembryonic antigen (CEA) CRP human immunoglobulin G (hIgG), horseradish peroxidase (HRP), and thrombin (TB). Figure 5 shows the DPV responses obtained before and after a competitive reaction. Except www.nature.com/scientificreports/ GAPDH, all tested proteins did not show any significant current changes after the competition, suggesting that the proposed immunosensor is highly selective and the above-mentioned proteins did not interfere with GAPDH detection. The stability of the fabricated sensor was determined by measuring the response of 100 pg/mL of GAPDH for one month. After each measurement, the immunosensor was washed with a PBS solution and dipped into a 0.2 M Gly-HCl buffer solution (pH=2.8) for 5 min. After three times washing with a PBS solution, the immunosensor was stored in a dry condition at 4 °C until it was further used for competitive binding of free and conjugated GAPDH. The current response did not find to be significantly decreased (0.516, 0.523, 0.488, and 0.482) for one month as shown in Fig. 6 . The immunosensor retained almost 93.4 % of its initial response for one month time period. These results indicated that the GAPDH immunosensor exhibited not only high selectivity but also long-term stability. The applicability of this GAPDH immunosensor for the analysis of real samples was investigated by using human blood serum. For this purpose, blood serum samples were prepared by spiking 0.1 ng/mL ±0.03 and 0.2 ng/mL GAPDH. To calculate the GAPDH concentration, the standard addition method was used; the obtained plot is shown in Fig. 7 . The concentration of GAPDH was detected at 0.1 ±0.03 and 0.19 ±0.03 ng/mL. The recovery was almost 100% for the first sample and 95% for the second sample, indicating acceptable accuracy. This result confirms that the proposed GAPDH immunosensor can be applied for GAPDH detection in real human serum samples. We developed an electrochemical immunosensor based on Cys-GO/QD platform to detect the GAPDH biomarker for PMI estimation. The Cys-GO/QD layer has the characteristics of a large surface area and excellent biocompatibility, which enable the immobilization of GAPDH antibodies. The co-existence of GO and QD amplified the electrochemical signal by enhancing the conductivity and generating numerous electrons for detection. More importantly, metallic stripping of QDs was induced by H 2 O 2 generated from enzymatic labels, and this www.nature.com/scientificreports/ novel sensing strategy further improved the detection sensitivity. The developed GAPDH immunosesnsor can detect GAPDH at a low concentration of 2.0 fg/mL with a broad linear scope between 1.0 fg/mL and 100 ng/ mL. The proposed detection strategy can be used in forensic field for the point-of-care detection of GAPDH and other PMI biomarkers and is promising for PMI estimation. No datasets were generated or analyzed during the current study. www.nature.com/scientificreports/ Degradation profile of mRNA in a dead rat body: basic semi-quantification study Degradation of kidney and psoas muscle proteins as indicators of post-mortem interval in a rat model, with use of lateral flow technology Immunosensors: The next generation Enhanced electrochemiluminescence of CdSe quantum dots composited with CNTs and PDDA for sensitive immunoassay Surface plasmon resonance imaging for affinity-based biosensors Immobilization of enzymes at high load/activity by aqueous electrodeposition of enzyme-tethered chitosan for highly sensitive amperometric biosensing Strategies for electrochemical immunoassay Reagentless amperometric carbohydrate antigen 19-9 immunosensor based on direct electrochemistry of immobilized horseradish peroxidase Amperometric micro-immunosensor for the detection of tumor biomarker DNA-based hybridization chain reaction for amplified bioelectronic signal and ultrasensitive detection of proteins H 2 -based electrochemical biosensor with Pd nanowires@ZIF-67 molecular sieve bilayered sensing interface for immunoassay Liposome-mediated in situ formation of Type-I heterojunction for amplified photoelectrochemical immunoassay Aptamer-based potentiometric measurements of proteins using ion-selective microelectrodes Potentiometric immunoassay with quantum dot labels Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor Glucose oxidase: natural occurrence, function, properties and industrial applications The chemistry of enzyme and protein immobilization with glutaraldehyde Multiple nonenzymatic labels-based impedimetric aptamer sensor for the competitive detection of thrombin Cation analysis scheme by differential pulse polarography Characterization of cysteamine self assembled on gold functionalized with nitrilotriacetic acid and evaluation of copper(II) binding capacity with adsorption transfer stripping voltammetry Self-assembled monolayers of cystamine and cysteamine on gold studied by XPS and voltammetry Functionalization of gold cysteamine self-assembled monolayer with ethylenediaminetetraacetic acid as a novel nanosensor Rethinking amide bond synthesis Amplified electrochemical detection of a cancer biomarker by enhanced precipitation using horseradish peroxidase attached on carbon nanotubes Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor Ultrasensitive Nanoimmunosensor by coupling non-covalent functionalized graphene oxide platform and numerous ferritin labels on carbon nanotubes Morphologically flex Sm-MOF based electrochemical immunosensor for ultrasensitive detection of a colon cancer biomarker Practice and theory of enzyme immunoassays A stable and sensitive voltammetric immunosensor based on a new non-enzymatic label Glucose oxidase as an analytical reagent Highly sensitive voltammetric thrombin aptamer sensor based on the synergistic effect of doping/depositing gold nanoparticles in polydopamine film All-solid-state SARS-CoV-2 protein biosensor employing colloidal quantum dots-modified electrode A fluorescent biosensor based on quantum dot-labeled streptavidin and poly-l-lysine for the rapid detection of Salmonella in milk Graphene quantum dots-based platform for the fabrication of electrochemical biosensors Cascade amplification based on PEI-functionalized metal-organic framework supported gold nanoparticles/ nitrogen-doped graphene quantum dots for amperometric biosensing applications Highly selective and sensitive detection of glutathione over cysteine and homocysteine with a turn-on fluorescent biosensor based on cysteamine-stabilized CdTe quantum dots A sensitive electrochemiluminescence biosensor for assay of cancer biomarker (MMP-2) based on NGQDs-Ru@SiO2 luminophore Carbon dots-thionine modified aptamer-based biosensor for highly sensitive cocaine detection The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-12444-6.Correspondence and requests for materials should be addressed to B.J., J.-S.C. or M.A.R.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.