key: cord-0031560-0h1gzs6m authors: Eriksson, Olof; Velikyan, Irina; Haack, Torsten; Bossart, Martin; Laitinen, Iina; Larsen, Philip J.; Berglund, Jan Erik; Antoni, Gunnar; Johansson, Lars; Pierrou, Stefan; Tillner, Joachim; Wagner, Michael title: Glucagonlike Peptide-1 Receptor Imaging in Individuals with Type 2 Diabetes date: 2022-05-03 journal: J Nucl Med DOI: 10.2967/jnumed.121.262506 sha: bd09a3fd2ffd08a70e316ae81d47e61ec05474df doc_id: 31560 cord_uid: 0h1gzs6m The glucagonlike peptide-1 receptor (GLP1R) is a gut hormone receptor, intricately linked to regulation of blood glucose homeostasis via several mechanisms. It is an established and emergent drug target in metabolic disease. The PET radioligand (68)Ga-DO3A-VS-exendin4 ((68)Ga-exendin4) has the potential to enable longitudinal studies of GLP1R in the human pancreas. Methods: (68)Ga-exendin4 PET/CT examinations were performed on overweight-to-obese individuals with type 2 diabetes (n = 13) as part of a larger target engagement study (NCT03350191). A scanning protocol was developed to optimize reproducibility (target amount of 0.5 MBq/kg [corresponding to peptide amount of <0.2 µg/kg], blood sampling, and tracer stability assessment). The pancreas and abdominal organs were segmented, and binding was correlated with clinical parameters. Results: Uptake of (68)Ga-exendin4 in the pancreas, but not in other abdominal tissues, was high but variable between individuals. There was no evidence of self-blocking of GLP1R by the tracer in this protocol, despite the high potency of exendin4. The results showed that a full dynamic scan can be simplified to a short static scan, potentially increasing throughput and reducing patient discomfort. The (68)Ga-exendin4 concentration in the pancreas (i.e., GLP1R density) correlated inversely with the age of the individual and tended to correlate positively with body mass index. However, the total GLP1R content in the pancreas did not. Conclusion: In summary, we present an optimized and simplified (68)Ga-exendin4 scanning protocol to enable reproducible imaging of GLP1R in the pancreas. (68)Ga-exendin4 PET may enable quantification of longitudinal changes in pancreatic GLP1R during the development of type 2 diabetes, as well as target engagement studies of novel glucagonlike peptide-1 agonists. hormone receptor intricately linked to regulation of blood glucose homeostasis via several mechanisms such as insulin secretion, gastric emptying, and control of food intake (1) . Endogenous GLP1 peptide is released from the intestinal L cells in response to nutrient intake. Synthetic GLP1 agonists are already approved for treatment of such conditions as type 2 diabetes (T2D), and further insight into their mechanism of action is still of the utmost interest. Several recent studies have demonstrated beneficial effects of GLP1 agonists on hemoglobin A1c, cardiac function, and survival (2, 3) . Exendin4 is a synthetic peptide that binds to GLP1R with nanomolar affinity and high specificity (4) . The development of 68 Ga-radiolabeled analogs of exendin4 (5, 6) has recently enabled noninvasive PET imaging in humans, primarily for the diagnosis and localization of insulinomas (7, 8) , as well as expression of GLP1R in the pancreas. The possibility of longitudinal imaging to quantify GLP1R density in the pancreas is of interest both in the assessment of drug mechanisms of action (e.g., in the context of unimolecular dual and trigonal agonists) (9, 10) and because of the potential association between GLP1R expression and the remaining b-cell mass (11) . Here, we used 68 Ga-DO3A-VS-exendin4 ( 68 for PET imaging of GLP1R in the human pancreas. The current study was performed as part of a clinical trial investigating the target engagement of a novel GLP1/glucagon receptor dual agonist, SAR425899, in individuals with T2D (clinicaltrials.gov identifier NCT03350191) (12) . Here, we demonstrate for the first time-to our knowledge-the noninvasive quantification of GLP1R density in the pancreas of individuals with T2D by PET imaging. We furthermore outline a protocol for reproducible, longitudinal, and accurate 68 Ga-exen-din4 PET/CT scanning and explore the origin of the variability of pancreatic GLP1R density this patient population. A 68 Ga-exendin4 PET/CT imaging study on healthy cynomolgus NHPs was in part reported and described in detail previously (5) . Briefly, NHPs were scanned by 68 PET using a dose escalation study design in which several examinations were performed, several hours apart, over the course of one or several experimental days. Each subsequent scan entailed a higher peptide mass and radioactive dose to minimize influence from the preceding scan (Table 1) . The resulting dataset enabled analysis of the self-blocking effect of the increasing amounts of coinjected unlabeled exendin4 precursor peptide. Previously, only the simplified SUV analysis of 3 of the NHPs (8 scans) was reported (5) . In preparation for the design of the clinical study, to better understand the peptide doses at which self-blocking starts to occur, we reanalyzed the dynamic NHP data from all 12 scans by graphical analysis using an image-derived blood plasma input. Pancreas and other tissues of interest (such as spleen as a negative reference tissue) were delineated using PMOD, version 4.0 (PMOD Technologies). The PET signal for each tissue and time frame was corrected for the injected amount, and the image-derived input function was extracted by segmenting voxels fully within the lumen of the descending aorta as identified on early PET frames and coregistered CT projections. The aorta signal was further corrected for the plasma partition. The volume of distribution (V t ) of 68 Ga-exendin4 in the pancreas was estimated by graphical analysis according to Logan by applying the image-derived input function using the PMOD PKIN module (13) . Patlak graphical analysis was also attempted (14) , assuming irreversible uptake of 68 in tissue due to receptor agonism and internalization, but this model failed in some individuals and is not reported. The pancreatic V t for each scan was plotted against the amount of coinjected unlabeled precursor peptide to explore the self-blocking at different doses. Furthermore, the pancreatic V t was plotted against the static uptake values at different time points, to determine whether static SUVs could replace full dynamic PET scans with invasive plasma sampling. These 68 Ga-exendin4 PET/CT examinations were acquired as part of a phase Ib single-center, open-label study assessing the glucagon receptor and GLP1R occupancy of dual-agonist SAR425899 in overweight-to-obese T2D patients (clinicaltrials.gov identifier NCT03 350191). Individuals with T2D (n 5 13) were recruited and underwent PET/CT scanning for GLP1R availability in the pancreas ( 68 and glucagon receptor availability in the liver ( 68 Ga-DO3A-VS-Tuna-2) at baseline. Participants were then treated with up to 0.12 or 0.2 mg of SAR425899 daily from 3 wk, followed by on-drug scanning with 68 Ga-exendin4 and 68 Ga-DO3A-VS-Tuna-2. Six participants completed the full NTC03350191 occupancy study, and the results from those individuals, especially the occupancy of SAR425899 as evaluated by PET, were previously reported (12) . This study reports the results of all 13 baseline 68 Ga-exendin4 PET scans and the details of the procedures. The baseline examination of the 13 68 Ga-DO3A-VS-Tuna-2 examinations was similarly reported independently (15) . Overweight-to-obese individuals diagnosed with T2D (n 5 13) were recruited to the study. The participants had a median age of 69 y (range, 50-76 y) and a mean body mass index (BMI) of 31.2 6 3.0 kg/m 2 . Of the 13 participants, 12 were men and 1 was a woman. Patients were not allowed to be on any antidiabetic medication during the study except for stable metformin or sulfonylurea treatment. No control group with nondiabetic individuals was included, since the full study was aimed at assessing drug efficacy and occupancy and thus included 3 wk of drug treatment with SAR425899. All study participants provided written informed consent. Study protocols were approved by national health authorities and an independent ethics committee, and the trial was performed in accordance with the guidelines established by the Declaration of Helsinki and the International Conference on Harmonization-Good Clinical Practice. Good-manufacturing-practice DO3A-exendin4 was provided by Sanofi. Good-manufacturing-practice-quality 68 Ga-exendin4 was produced on an automated synthesizer (Modular Lab Pharm Tracer; Eckert and Ziegler) as developed and reported previously (12, 16) . The radiochemical purity was over 90%, with no unknown single impurity of over 5%. The PET assessments were performed 3 h after a standardized meal followed by fasting, to minimize the variability in GLP1 levels at the time of scanning. The individuals were examined over the abdomen with a Discovery MI PET/CT scanner (20-cm field of view; GE Healthcare). Low-dose CT was performed for attenuation correction and anatomic coregistration of PET images. The dose of the CT scan was limited by dosimetry considerations, given that each individual underwent up to 4 PET/CT examinations over the entire clinical study. A 0.5 MBq/kg target dose of 68 Ga-exendin4 (0.46 6 0.03 MBq/kg, corresponding to 0.14 6 0.04 mg of peptide per kilogram) was administered intravenously as a bolus. The amount of administered 68 Ga-exendin4 was based primarily on limiting the associated dose of DO3A-VS-exendin4 precursor peptide to below 0.2 mg/kg. This limit was imposed to minimize any self-blocking, and the cutoff was determined from the NHP dose escalation studies. Dynamic PET was initiated at administration and continued for 60 min. Blood sampling for glucose was performed before and during the scan as a safety precaution, as exendin4 can stimulate insulin secretion at pharmacologic doses. For 3 individuals, arterial sampling was performed at 5, 30, and 60 min after 68 Ga-exendin4 administration to measure the radioactivity in whole blood and plasma and to determine the metabolic stability of the tracer (the methods are shown in the supplemental materials, available at http://jnm.snmjournals.org) (17) . PET images were reconstructed using an iterative VUE Point FX-S algorithm (GE Healthcare) (3 iterations, 3 subsets, 256 3 256 matrix, 3-mm z-axis postprocessing filter) with all relevant corrections performed (30 frames in total: 12 3 10 s, 6 3 30 s, 5 3 120 s, 5 3 300 s, 2 3 600 s). Abdominal tissues of interest, including pancreas (target tissue), aorta (input signal), kidney (excretion), and spleen and erector spinae muscle (negative reference tissues) were manually segmented on coregistered PET/CT images using Carimas software, version 2.9 (Turku PET Center). The aorta was delineated by segmenting single voxels fully within the lumen of the descending aorta. The arterial plasma image-derived input function was generated by correcting the aorta signal for plasma-to-whole-blood partitioning and for the percentage of intact 68 Ga-exendin4 during the scan (based on a population estimate). The kinetic data were fitted to different compartmental models and graphical analyses, including 1-and 2-tissue-compartment models and Patlak and Logan analysis. On the basis of the fitting, performance, and complexity of the models (Supplemental Tables 1-5) , Patlak graphical analysis was selected as the optimal analysis method for the dynamic PET data. Furthermore, 68 Ga-exendin4 triggers internalization in GLP1R-positive tissues, leading to intracellular 68 Ga trapping (Supplemental Figs. 1A-1B), theoretically fulfilling the irreversible binding criteria during the time of the scanning as assumed in Patlak analysis. The 68 Ga-exendin4 net uptake rate (K i ) was estimated using Patlak graphical analysis in Microsoft Excel (14) . K i (mL/[mLÁh]) was considered a measurement of the concentration of 68 Ga-exendin4 binding in the pancreas (likely proportional to the GLP1R density in the pancreas). The total GLP1R content was thus estimated by multiplying K i (mL/[mLÁh]) by the pancreatic volume (mL) as segmented from the PET/CT images. Data on a group level are reported as mean 6 SD. Differences between groups were assessed by 1-way ANOVA. Correlations were assessed by linear regression and the Pearson correlation coefficient (GraphPad Prism for Mac [Apple], version 8.0). The data that support the findings of this study are available from Sanofi, but restrictions apply to the availability of these data, which were used under license for the current study and therefore are not publicly available. Data are, however, available from the authors on reasonable request and with the permission of Sanofi. 68 Ga-exendin4 exhibited visually strong binding and a high V t in the pancreas on all scans coinjecting up to a 0.2 mg/kg dose of unlabeled DO3A-VS-exendin4 precursor peptide (Fig. 1A) . There was already a sharp decrease in binding at a peptide mass dose of 1 mg/kg, whereas doses in excess of 10 mg/kg reduced the pancreas binding to the background level. The dose inducing a 50% decrease in binding (the in vivo half-maximal inhibitory concentration) was estimated to be approximately 0.45 mg/kg, indicating very high potency. Binding was also estimated with a simple semiquantitative SUV measurement of pancreatic binding during the static time frame from 50 to 60 min after injection (SUV 55 min ). SUV 55 min correlated strongly with V t (P , 0.0001, r 5 0.96) (Fig. 1B) . Binding and Biodistribution in Individuals with T2D 68 Ga-exendin4 was rapidly distributed in the abdominal tissues after intravenous administration ( Figs. 2A and 2B) . Initially, the aorta and the left ventricle (i.e., blood signal) were clearly seen, followed by uptake in the pancreas, kidney, and liver in the first 5 min. For the remainder of the scan (60 min), increasing uptake in the pancreas and kidney continued, whereas the remaining tissues demonstrated clearance. After 60 min, the uptake of 68 Ga-exendin4 (assessed as SUV 55 min ) was clearly higher in the pancreas than in, for example, the spleen, which has high perfusion comparable to that of the pancreas but is devoid of GLP1R (Fig. 2C) . There was marked variability, almost 4-fold, in the magnitude of the pancreas uptake in different individuals (Figs. 2C and 2D) . Importantly, this variability was not reflected in other abdominal tissues or the blood signal, indicating it is not due to general differences in biodistribution or metabolism. 68 Ga-exendin4 uptake was obvious in all 3 pancreatic segments-caput (head), corpus (body), and cauda (tail)-but tended to be higher in the cauda. However, separate delineation of the cauda was difficult because of potential spillover from the kidney in some individuals. Metabolic Stability, Self-Blocking, and Protocol Simplification After administration, 68 Ga-exendin4 demonstrated high stability in the blood, with more than 90% of the intact tracer being present in plasma at 60 min ( Table 2 ). 68 Ga-exendin4 also exhibited high plasma partitioning (%1.8) throughout the scan; that is, most tracer was free in the plasma and available for distribution into tissue ( Table 2 ). The net K i of 68 Ga-exendin4 in the pancreas was calculated by Patlak graphical analysis, using the metabolite-corrected arterial plasma curve as input ( Table 3) . As per the study design, all individuals were administered less than a 0.2 mg/kg dose of DO3A-VS-exendin4 peptide to avoid self-blocking due to the high potency of the compound for GLP1R. As predicted, there was no negative correlation between the peptide mass dose and the net K i , indicating that the selfblocking at these levels was also negligible in humans (Fig. 3A) . SUV 55 min correlated well with the net K i (P , 0.0001, r 5 0.92), indicating that the lengthy dynamic scanning and invasive blood sampling may be replaced by shorter static scanning from 50 to 60 min after tracer administration with only a minor loss in accuracy (Fig. 3B) . There was a distinct variability in the 68 Ga-exendin4 net K i in the pancreas. We therefore explored the potential correlation between 68 Ga-exendin4 binding and the characteristics and biometrics of patients. The variability in 68 Ga-exendin4 binding as assessed by K i (i.e., GLP1R density) correlated negatively with the age of the participant (P , 0.05, r 5 20.61) (Fig. 4A) . The same correlation with age, but using SUV 55 min , was 20.50 (P 5 0.082). Furthermore, there was a tendency toward a positive correlation between 68 Ga-exendin4 binding in the pancreas and the BMI of the participants (P 5 0.064, r 5 0.53) (Fig. 4B) . Similarly, the correlation between BMI and SUV 55 min was 0.43 (P 5 0.145). However, when we estimated the total 68 Ga-exendin4 binding (i.e., total GLP1R content) by multiplying by the pancreatic volume, no correlations remained (Figs. 4C and 4D). The pancreatic volume of the participants ranged between 48 and 135 mL and did not correlate with, for example, age or BMI in this cohort (Figs. 4E and 4F). In this study, we demonstrated the binding and biodistribution of 68 Ga-exendin4 in the pancreas of humans with T2D. Furthermore, we developed an optimized and simplified 68 scanning protocol based on these initial experiences. Native exendin4 is a highly potent GLP1R agonist, with subnanomolar potency (18) . Radiolabeled 68 Ga-exendin4 has excellent specificity for GLP1R (Supplemental Fig. 1A) and affinity in the nanomolar range (19) . In the absence of suitable antagonists, agonists such as exendin4 can be used as PET tracers, but care must be taken to avoid unwanted pharmacologic effects. We have previously demonstrated that 68 Ga-exendin4 also exhibits self-blocking at low administered precursor peptide mass doses in NHPs. Doses of around 0.5 mg/kg elicit up to 50% blocking of the signal. This result is not entirely unexpected, given the high potency of 68 Ga-exendin4 for GLP1R. In fact, peptide mass effects of similar magnitude were seen for 2 other gut hormone peptide PET tracers, 68 Ga-DO3A-VS-Tuna-2 (a glucagon receptor agonist) and 68 Ga-S02-GIP-T4 (a glucose-dependent insulinotropic polypeptide receptor agonist), both with a potency in the picomolar range (20, 21) . Here, we further demonstrated from NHP data that a peptide mass effect can be avoided at less than 0.2 mg/kg doses of coinjected DO3A-VS-exendin4. This finding influenced the design of the clinical study, which subsequently showed minimal mass effects. Thus, any future clinical studies with 68 Ga-exendin4 should aim to administer no more than a 0.2 mg/kg dose of precursor peptide. This limitation will likely entail an optimized automated radiochemistry setup (16) , since a molar activity of at least 20-30 MBq/nmol will be required. Furthermore, even at an optimal molar activity, 0.2 mg/kg will probably correspond to no more than 50-100 MBq to be administered; this, in turn, necessitates highly sensitive PET instrumentation for sufficient image quality. Quantitative PET assessment usually entails quite complex correction of imaging data, including dynamic imaging acquisition of a long duration, arterial sampling, and metabolic stability measurement. Such complicated scanning protocols present logistical challenges and are uncomfortable for the patient. Additionally, the 68 Ga-exen-din4 was rapidly distributed, followed by washout from most tissues except pancreas and kidneys (average of 13 individuals). Representative maximum-intensity-projection PET images are shown. (C) There was strong variability in pancreas binding, which was not reflected in other tissues. (D) Representative transaxial PET/CT images demonstrate high, average, or low pancreas binding of 68 Ga-exendin4. ****indicates P , 0.0001. analysis is time-consuming and requires specialized software and expertise. Semiquantitative measurements derived from static scanning protocols, such as SUVs, on the other hand, are simpler from the point of view of both the patient and the hospital, in addition to allowing for rapid analysis. In both the NHP and the clinical studies, we could show that the static SUV (SUV 55~min ) exhibited a very strong correlation with the modeled parameter (which was derived from the full dynamic scanning protocol including blood sampling and metabolic stability correction of the input signal). Thus, it can be assumed that a shortened static scan at 50-60 min after injection provides reasonable accuracy in the assessment of GLP1R density in the pancreas, with only a minor loss in reproducibility compared with a full dynamic scan. In many cases, this trade-off may be acceptable to substantially increase patient comfort and simplify scanning procedures and logistics. However, 68 Ga-exendin4 uptake as assessed by SUV 55 min did not correlate as well with, for example, age as did Patlak net K i , indicating that the simplification of the analysis and scanning protocol may reduce the power of the assessment. A limitation of this study is the lack of a test-retest assessment, that is, repeated scanning of the same subject without any intervention in between. Such data would provide important information on the reproducibility of the assessment-either analyses by SUV 55 min or analyses by Patlak net K i . Unfortunately, test-retest scanning was not possible because of the design of the full occupancy study (clinicaltrials.gov identifier NCT03350191) (12) . In short, future PET studies using 68 Ga-exendin4 for assessment of GLP1R in the pancreas should aim to coinject less than a 0.2 mg/kg dose of peptide. Moreover, patient comfort and scanning throughput could be increased by limiting the scanning protocol to a static scan approximately 60 min after injection. Despite the rigorous standardization of our scanning protocol, 68 Ga-exendin4 exhibited a marked variability in pancreatic binding. We further explored potential reasons for this variability. There was a negative correlation with age in this study, indicating a lower GLP1R density in the pancreas of older individuals. A progressive decrease in GLP1R in the mouse brain has previously been reported (22) . One of the major sources of 68 Ga-exendin4 binding in the human pancreas is the b cells, which exhibit strong GLP1R expression (23) . The known decline of b-cell number and function with age (24) thus presents a possible mechanism for this reduction in 68 Ga-exendin4 with increasing age. However, when we calculated the total GLP1R content (by multiplying 68 binding by the pancreas volume), the negative correlation did not prevail. We also visually observed a general trend toward higher 68 Ga-exendin4 uptake . In vivo binding of 68 Ga-exendin4 in human T2D pancreas. (A) There was no obvious self-blocking mass effect at peptide doses below 0.2 mg/kg (i.e., no negative correlation). (B) In human pancreas, there was strong correlation between model parameter obtained from dynamic scan including blood (Patlak K i ) and SUV 55 min , indicating that static scan is sufficient for accurate quantification. Pancreatic GLP1R density (concentration of 68 Ga-exendin4 binding) correlated negatively with age of examined individuals (A) and exhibited tendency to correlate with BMI (P 5 0.064) (B). (C and D) However, total pancreas GLP1R content (i.e., 68 Ga-exendin4 concentration multiplied by volume) did not correlate with age (C) or BMI (D) of participants. (E and F) Similarly, size of pancreas did not correlate with either age (E) or BMI (F) in this study. in the cauda of the pancreas in many individuals. This is again interesting in the context of b cells, since the cauda has been shown to exhibit approximately 2-fold the islet density of the caput and the corpus (25) . Thus, we observed several features of the 68 Ga-exendin4 binding that were consistent with known b-cell distribution and function. Additionally, the large variability in 68 Ga-exendin4 observed here (almost 4-fold) is in line with the large variability in b-cell mass seen in individuals with T2D as assessed by biopsy morphometric studies (26) . More studies dedicated to this question are required to further establish the association between 68 Ga-exendin4 binding and the b-cell mass in the human pancreas in T2D. We observed a trend toward a positive correlation between 68 Ga-exendin4 binding and BMI in this cohort; that is, an increasing pancreatic GLP1R density correlated with a higher BMI. It is difficult to assess whether this is a reasonable observation, as there are limited data on GLP1R density in the pancreas of obese subjects-likely because of the challenge of obtaining diverse biopsy material of high quality, lack of reliable monoclonal antibodies for GLP1R, and the time-consuming effort required for sectioning, staining, and analyzing a sufficiently large dataset to draw firm conclusions. Again, the correlation with BMI did not remain when the total GLP1R content in the pancreas was estimated by multiplying by volume. A limitation of the study and the correlations discussed above is the imbalanced sex distribution of the study population. Of the 13 included individuals, 12 were male and only 1 was female. Pancreatic binding in the female individual in this study was around the population average. However, the correlations seen here may reflect mainly the male population. 68 Ga-exendin4 could conceivably serve as a biomarker for response to therapy. GLP1 efficacy studies sometimes delineate subgroups of nonresponding individuals-both in studies targeting populations with diabetes (27) and in studies targeting populations with neurologic disease (28) . In this small cohort, some of the participants (n 5 7) completed 3 wk of up-titration with the dual GLP1/glucagon agonist SAR425899, and all responded to treatment with blood glucose lowering and weight reduction, regardless of exhibiting a wide range of GLP1R density in the pancreas (12) . Therefore, excessively up-or down-regulated GLP1R in the pancreas does not seem to predict GLP1 agonist responders or nonresponders in this admittedly small cohort. CONCLUSION We present an optimized and simplified 68 Ga-exendin4 scanning protocol to enable reproducible imaging of GLP1R in the human pancreas. 68 Ga-exendin4 PET may enable longitudinal quantification of changes in pancreatic GLP1R during the development of T2D, as well as target engagement studies of novel GLP1 agonists. The clinical study was sponsored by Sanofi and was performed in collaboration with Antaros Medical AB. The NHP study was sponsored by JDRF, Diabetesfonden, and Barndiabetesfonden. Glucagon-like peptide 1 in health and disease Liraglutide and cardiovascular outcomes in type 2 diabetes SUSTAIN-6 Investigators. Semaglutide and cardiovascular outcomes in patients with type 2 diabetes Isolation and characterization of exendin-4, an exendin-3 analogue, from Heloderma suspectum venom: further evidence for an exendin receptor on dispersed acini from guinea pig pancreas In vivo imaging of the glucagon like peptide-1 receptor in pancreas by [ 68 Ga]DO3A-exendin4 PET-based human dosimetry of 68 Ga-NODAGA-exendin-4, a tracer for b-cell imaging Glucagon-like peptide-1 receptor imaging for the localisation of insulinomas: a prospective multicentre imaging study Detection of metastatic insulinoma by positron emission tomography with [ 68 Ga]exendin-4: a case report A novel dual glucagon-like peptide and glucagon receptor agonist SAR425899: results of randomized, placebo-controlled first-in-human and first-in-patient trials Efficacy and safety of LY3298176, a novel dual GIP and GLP-1 receptor agonist, in patients with type 2 diabetes: a randomised, placebo-controlled and active comparator-controlled phase 2 trial Validation of 111 In-exendin SPECT for the determination of the b-cell mass in BioBreeding diabetes-prone rats Receptor occupancy of dual glucagon-like peptide 1/glucagon receptor agonist SAR425899 in individuals with type 2 diabetes mellitus Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11 C-methyl]-(2)-cocaine PET studies in human subjects Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data Hepatic binding, biodistribution and dosimetry of glucagon receptor PET tracer [ 68 Ga]Ga-DO3A-VS-Tuna-2 in human subjects with type 2 diabetes Fully automated GMP production of Cys 40 -exendin-4 for clinical use Pre-clinical evaluation of [ 68 Ga]Ga-DO3A-VS-Cys 40 -exendin-4 for imaging of insulinoma Exendin-4 is a high potency agonist and truncated exendin-(9-39)-amide an antagonist at the glucagon-like peptide 1-(7-36)-amide receptor of insulin-secreting beta-cells Species differences in pancreatic binding of DO3A-VS-Cys 40 -exendin4 First-in-class positron emission tomography tracer for the glucagon receptor Drug occupancy assessment at the gastric inhibitory polypeptide (GIP) receptor by positron emission tomography Age-related change of GLP-1R expression in rats can be detected by Cys 39 -exendin-4 Immunohistochemical assessment of glucagon-like peptide 1 receptor (GLP-1R) expression in the pancreas of patients with type 2 diabetes The role of aging upon b cell turnover Regional differences in islet distribution in the human pancreas: preferential beta-cell loss in the head region in patients with type 2 diabetes Pancreatic betacell mass in European subjects with type 2 diabetes Determining predictors of early response to exenatide in patients with type 2 diabetes mellitus Exenatide once weekly versus placebo in Parkinson's disease: a randomised, double-blind, placebo-controlled trial We thank Eduard Kober, H el ene Savoye (both employed by Sanofi), and M elanie Bovo (employed by Business France) for their support during the conduct and analysis of this study. We thank Ramkumar Selvaraju and Olle Korsgren for assistance during the conduct of the NHP study. QUESTION: Can GLP1R density in the pancreas of individuals with T2D be evaluated by 68 Ga-exendin4 PET?