key: cord-0031558-u067clsi authors: Bag, Asim K.; Wing, Melissa N.; Sabin, Noah D.; Hwang, Scott N.; Armstrong, Gregory T.; Han, Yuanyuan; Li, Yimei; Snyder, Scott E.; Robinson, Giles W.; Qaddoumi, Ibrahim; Broniscer, Alberto; Lucas, John T.; Shulkin, Barry L. title: (11)C-Methionine PET for Identification of Pediatric High-Grade Glioma Recurrence date: 2022-05-03 journal: J Nucl Med DOI: 10.2967/jnumed.120.261891 sha: 6c5fad52654d70e8497082baa0ec26176d72f0e0 doc_id: 31558 cord_uid: u067clsi Differentiating tumor recurrence or progression from pseudoprogression during surveillance of pediatric high-grade gliomas (PHGGs) using MRI, the primary imaging modality for evaluation of brain tumors, can be challenging. The aim of this study was to evaluate whether (11)C-methionine PET, a molecular imaging technique that detects functionally active tumors, is useful for further evaluating MRI changes concerning for tumor recurrence during routine surveillance. Methods: Using (11)C-methionine PET during follow-up visits, we evaluated 27 lesions in 26 patients with new or worsening MRI abnormalities for whom tumor recurrence was of concern. We performed quantitative and qualitative assessments of both (11)C-methionine PET and MRI data to predict the presence of tumor recurrence. Further, to assess for an association with overall survival (OS), we plotted the time from development of the imaging changes against survival. Results: Qualitative evaluation of (11)C-methionine PET achieved 100% sensitivity, 60% specificity, and 93% accuracy to correctly predict the presence of tumors in 27 new or worsening MRI abnormalities. Qualitative MRI evaluation achieved sensitivity ranging from 86% to 95%, specificity ranging from 40% to 60%, and accuracy ranging from 85% to 89%. The interobserver agreement for (11)C-methionine PET assessment was 100%, whereas the interobserver agreement was only 50% for MRI (P < 0.01). Quantitative MRI and (11)C-methionine PET evaluation using receiver-operating characteristics demonstrated higher specificity (80%) than did qualitative evaluations (40%–60%). Postcontrast enhancement volume, metabolic tumor volume, tumor-to-brain ratio, and presence of tumor as determined by consensus MRI assessment were inversely associated with OS. Conclusion: (11)C-methionine PET has slightly higher sensitivity and accuracy for correctly predicting tumor recurrence, with excellent interobserver agreement, than does MRI. Quantitative (11)C-methionine PET can also predict OS. These findings suggest that (11)C-methionine PET can be useful for further evaluation of MRI changes during surveillance of previously treated PHGGs. It has only recently been discovered that pediatric high-grade gliomas (PHGGs) are biologically distinct from adult high-grade gliomas (1) . However, this new knowledge has not yet changed diagnoses, classifications, World Health Organization grading, or treatment of PHGGs (2) . PHGGs in children older than 3 y are treated with a combination of maximal safe surgical resection, radiation therapy with or without adjuvant chemotherapy, and subsequent continued chemotherapy, similar to the treatment regimen for adult high-grade gliomas (3) (4) (5) . Despite this aggressive therapy, outcomes in young children are dismal, with a local 1-y failure-free survival rate of 60% (6) , suggesting that recurrence is common. Accurate diagnosis of tumor recurrence is important because the median overall survival (OS) of recurrent PHGGs is 4-7 mo (7) and because treatment of pseudoprogression is different from that of tumor recurrence. However, the diagnosis of recurrence is not always straightforward with MRI, which is the clinical standard-of-care test for assessing response to treatment. Indeed, treatment-related effects, including pseudoprogression, frequently mimic tumor recurrence, thereby leading to misdiagnosis and incorrect management (8, 9) . Pseudoprogression is characterized by temporary enlargement and increased enhancement of clinical target volumes with MRI (10) and occurs in up to 20% of patients treated with radiation therapy and adjuvant chemotherapy (11) . The incidence of pseudoprogression after initial therapy of PHGGs is similar to the incidence in adults after treatment of high-grade gliomas (12) . Tumor recurrence is also characterized by enlargement of tumor volume, with increased enhancement making the distinction challenging (13) (14) (15) . Many advanced MRI techniques have been extensively studied to differentiate treatment-related effects from true tumor progression, with variable benefits (16) (17) (18) (19) . PET with various radiotracers has been studied to distinguish true tumor progression from pseudoprogression (17, (20) (21) (22) (23) (24) . Of the many PET radiotracers used to evaluate tumor recurrence, study results using amino acid PET tracers (i.e., 11 C-methionine, O-(2-18 F-fluoroethyl)-Ltyrosine [ 18 F-FET], and 18 F-dihydroxyphenylalanine) in adults suggest that a reduction in amino acid uptake or a decrease in the metabolically active tumor volume is a sign of treatment response associated with long-term outcome (25) . The Response Assessment in Neuro-Oncology working group and the European Association for Neuro-Oncology now suggest that 18 F-FET may facilitate the diagnosis of pseudoprogression in glioblastoma patients within the first 12 wk after completion of chemoradiotherapy (25) . 11 C-methionine, a true amino acid PET tracer with properties similar to 18 F-FET PET, has recently been shown to differentiate true tumor progression from treatment-related effects better than other PET tracers can in adults, with a sensitivity and specificity of 91.2% and 87.5%, respectively (26) . Although the utility of 11 C-methionine PET for evaluating nonenhancing PHGGs has been investigated (27) , its use to evaluate tumor recurrence in PHGGs has not been systematically investigated. Here, we evaluated whether 11 C-methionine PET can be useful for the identification of tumor recurrence in previously treated PHGGs. Specifically, we compared the accuracy of 11 C-methionine PET with that of MRI for predicting the presence of tumors when recurrence is suspected. We also compared the interobserver agreement of 11 C-methionine PET and MRI to determine whether 11 C-methionine PET imaging adds value to conventional MRI and whether 11 C-methionine PET or MRI can predict OS. We retrospectively included all subjects with PHGGs who were enrolled in the ongoing "Methionine PET/CT Studies in Patients with Cancer" clinical trial (NCT00840047) at St. Jude Children's Research Hospital since 2009. This study was approved by the St. Jude Institutional Review Board, and each subject or a parent or legal guardian gave written informed consent to participate. The inclusion criteria for this study were as follows: previously treated World Health Organization grade III or IV PHGGs that demonstrated worsening or new imaging abnormalities on fluid-attenuated inversion recovery (FLAIR) sequences, on postcontrast T1-weighted sequences, or on both sequences during routine surveillance MRIs, in comparison with the MRI findings from the baseline or from the best response; 11 C-methionine PET scans obtained within 3 wk of the surveillance MRI scans; and establishment of a definitive diagnosis of tumor recurrence within 8 wk of either the MRI surveillance scan or the 11 C-methionine PET scan. Imaging Acquisition 11 C-Methionine PET. 11 C-methionine was prepared as previously described (28) . 11 C-methionine PET imaging followed at least 4 h of fasting. Each subject received intravenous injections of 740 MBq (20 mCi) of 11 C-methionine per 1.7 m 2 of body surface area (maximum prescribed dose, 740 MBq). Transmission CT images (for attenuation correction and lesion localization) and PET images were acquired approximately 5-15 min (mean 6 SD, 8.7 6 3.3 min) after 11 C-methionine injection with a Discovery 690 PET/CT scanner or a Discovery LS PET/CT scanner (GE Healthcare) using these parameters: field of view, 30 cm; matrix, 192 3 192; reconstruction method, VUE point HD; quantification method, SharpIR; filter cutoff, 5.0 mm; subsets, 34; iterations, 4; and z-axis filter, standard. The Q.Clear 350 SharpIR quantification method was used in only 1 subject. The CT acquisition parameters were as follows: 0.5-cm slice thickness, 0.8-s tube rotation, 1.5 cm/rotation table speed, 1.5:1 pitch, 120 kV, and 90 mA with dose modulation. PET images were acquired in 3-dimensional mode for 15 min. Data were reconstructed into multiplanar cross-sectional images with standard vendor-supplied software and displayed on a nuclear medicine workstation (Hermes Medical Systems, Inc.) for analysis. MRI. The following sequences were acquired with a 1.5-T Avanto magnet or a 3-T TrioTim, Skyra, or Prisma magnet (Siemens Medical Solutions) with a 0.1 mmol/kg dose of intravenous gadobutrol (Gadavist; Bayer Healthcare): 3-dimensional magnetization-prepared rapid gradientecho (1 mm 3 isotropic acquisition, 1,590-ms repetition time, 2.7-ms echo time, 900-ms inversion time, and 15 flip angle); 2-dimensional (2D) transverse T1-weighted fast low-angle shot (4-mm slice thickness, no gap, 259-ms repetition time, 2.46-ms echo time, and 70 flip angle); 2D transverse diffusion-weighted sequence and postcontrast 2D transverse T1-weighted fast low-angle shot (parameters identical to those of precontrast axial 2D T1-weighted); 2D transverse T2-weighted turbo spinecho (4-mm slice thickness, no gap, 4,810-ms repetition time, 87-ms echo time, and 180 flip angle); 2D transverse T2-weighted FLAIR (4-mm slice thickness, no gap, 10,000-ms repetition time, 106-ms echo time, 2,600-ms inversion time, and 130 flip angle); and 3-dimensional sagittal T1weighted (parameters identical to those of precontrast sagittal 3-dimensional T1-weighted). Apparent diffusion coefficient maps were calculated from the diffusion images with the vendor-provided software (Syngo; Siemens Healthcare). Qualitative Image Analysis MRI. Each surveillance MRI was evaluated 4 times. The first evaluation was performed during generation of the clinical report by one of the neuroradiologists assigned to the clinical service. The second evaluation was performed by a single neuroradiologist (observer 1) with 12 y of experience evaluating response assessments in pediatric brain tumors. The third evaluation was performed by a single neuroradiologist (observer 2) with 8 y of experience evaluating response assessments in pediatric brain tumors. Both observers were masked to the 11 C-methionine PET findings and did not have access to any clinical information or any imaging studies obtained after the index surveillance MRI. The fourth evaluation consisted of a consensus evaluation by observers 1 and 2. New or worsening MRI abnormalities were subjectively categorized as definitely tumor (score of 1), definitely not tumor (score of 2), or indeterminate (score of 3). The consensus readings were also scored with the same 1-3 scale. If a discrepancy in opinion occurred between 2 observers, the reading was scored as 3. The first rating from neuroradiologists on clinical duties was scored with the same scale on the basis of the clinical reports. Diffusion and apparent diffusion coefficient maps were used together for subjective evaluation only. 11 C-Methionine PET. 11 C-methionine PET images were independently reviewed by 2 observers, one with 15 y of experience and the other with 2 y of experience in molecular imaging for assessment of treatment response in pediatric brain tumors. The observers were provided the location of the MRI abnormality and had access to the MR images. The 11 C-methionine PET images were rated qualitatively on a 4-point scale relative to frontal white matter (in all included subjects, at least some component of the frontal lobe white matter was free of tumor): 0, no detectable uptake; 1, mild uptake but less than in the contralateral frontal lobe white matter; 2, mild uptake similar to that in the contralateral frontal lobe white matter; or 3, uptake greater than in the contralateral frontal lobe white matter. Finally, the results of visual assessment were consolidated into just 2 groups. The first group was "no uptake or uptake the same as or lower than in the reference region" (grades 0, 1, and 2), and the second group was "uptake higher than in the reference region" (grade 3). Worsening or new imaging abnormalities on postcontrast T2weighted FLAIR and T1-weighted sequences were manually segmented using Vitrea Advanced Visualization (Vital Images) software. Three patients had subtle enhancement on T1-weighted sequences, and their T1-weighted regions of interest were drawn on the D-T1 images (precontrast T1-weighted images were subtracted on a voxelby-voxel basis from the postcontrast T1-weighted images). SUVs for the 11 C-methionine PET images were calculated using Hermes software. After coregistration of the PET dataset with FLAIR or postcontrast T1-weighted MRI sequences, regions of interest were manually drawn either around the areas of abnormal 11 C-methionine uptake or around the MRI abnormality. In addition, quantitative tumor metrices (metabolic tumor volume and tumor-to-brain ratio [TBR]) were calculated as suggested by Law et al. (29) . However, instead of using a crescentic region of interest, we used a 1.0-cm 3 sphere to calculate the SUV mean of the contralateral normal prefrontal lobe cortex and juxtacortical white matter as suggested by Hotta et al. (22) for consistency. Briefly, SUV mean of the contralateral normal frontal lobe cortex and juxtacortical white matter was calculated using a 1.0 cm 3 sphere. The 3-dimensional metabolic tumor volume with an SUV more than 1.3 times that of the normal brain cortex (obtained in the prior step) was automatically contoured using Hermes software, which automatically calculated the SUVmax and SUV mean of the tumor. TBR and TBR max were then manually calculated by dividing the tumor SUV max by the SUV mean of the contralateral normal frontal lobe cortex. TBR mean was manually calculated by dividing the tumor SUV mean by the SUV mean of the contralateral normal frontal lobe cortex. In lesions with an SUV less than 1.3 times that of the contralateral frontal lobe, a volume of interest was manually drawn on the FLAIR-abnormal areas and agreed on by both nuclear medicine physicians, and then the volumes of interest were copied to the PET images. The SUV max of the volumes of interest were automatically calculated by the software. The TBR was then calculated as described above. The final outcomes of the lesions evaluated with MRI and 11 C-methionine PET were determined with the following methods: Response Assessment in Neuro-Oncology criteria applied to imaging and clinical findings (30); biopsies; or follow-up imaging and clinical course. Tumor was defined as present in the evaluated lesions if the lesions were treated as progressive disease (defined by Response Assessment in Neuro-Oncology criteria), if a predominant tumor was evident via biopsy, if progressive worsening was evident by follow-up MRI within 8 wk of the surveillance MRI or 11 C-methionine PET scan, or if the subject died of tumor progression without any other identifiable cause. Because all evaluated lesions were included at recurrence, OS was calculated from the date of diagnosis of recurrent tumor or pseudoprogression. MRI and 11 C-methionine PET readings were defined as true positive when tumor scores correctly identified the final outcome and as false positives when tumors scores differed from the final outcome. Ratings were defined as true negatives when tumor scores did not correctly identify the final outcome and as false negatives when tumor scores did not differ from the final outcome. Sensitivity and specificity were calculated by standard statistical definitions. Accuracy was defined as the proportion of true positives and true negatives in all scans. Interobserver agreement between different MRI and 11 C-methionine PET observers was calculated with Cohen k-values, which were interpreted as previously indicated (31) . Log-rank tests were used to assess the association of subjective 11 Cmethionine PET and MRI findings with OS. By using optimal cutoffs, we generated Kaplan-Meier curves for MRI parameters (T1-enhancing volumes, FLAIR volumes), and a PET parameter (SUV max ) to test whether these measurements from quantitative imaging analysis were associated with OS. The sensitivity and specificity of metabolic tumor volume, TBR, T1enhancing volume, FLAIR volume, and SUV max using optimal cutoffs for predicting final outcomes were evaluated. We used the optimized cutoffs to categorize these imaging features, and log-rank tests were performed to test whether each of these features was associated with OS values, which were calculated from the time of the MRI and 11 C-methionine PET scans to the death of the subjects or-for subjects still alive-to the date of the last follow-up. The 95% CIs for all diagnostic accuracy measures were calculated using bias-corrected bootstrap methods with resampling. All statistical analyses were done using R Statistical Software. We used May 2020 as the cutoff for our analysis and found 27 patients who matched our inclusion criteria. We excluded 1 patient with L-2-hydroxyglutaric aciduria because differentiating tumor tissue from healthy brain was challenging because of diffuse brain signal abnormalities in the entire brain due to this condition. Of the remaining 26 patients, 27 tumors (1 patient had a left frontal lobe recurrence that was treated and evaluated similarly to the original tumor in the cerebellum) were included in the analysis. Details of patient demographics and tumors are shown in Table 1 and Supplemental The final outcome in 5 of the 27 lesions evaluated were no tumor present (i.e., pseudoprogression), and in the remaining 22 lesions it was presence of tumor (i.e., tumor progression). The final outcomes were confirmed by follow-up MRI in 16 cases, by biopsy in 4, and by Response Assessment in Neuro-Oncology criteria in 7. The sensitivity, specificity, and accuracy of correctly predicting the presence of tumors from MRI were 86% (95% CI, 64%-96%), 80% (95% CI, 0%-100%), and 85% (95% CI, 63%-93%), respectively, for observer 1 and 95% (95% CI, 73%-100%), 40% (95% CI, 0%-100%), and 85% (95% CI, 63%-93%), respectively, for observer 2. The interobserver agreement was fair (Cohen k 5 0.49; P , 0.001). The sensitivity, specificity, and accuracy for correctly predicting the presence of tumors by consensus readings were 95% (95% CI, 71%-100%), 60% (95% CI, 0%-100%), and 89% (95% CI, 67%-93%), respectively. The details are summarized in Table 2 . The sensitivity, specificity, and accuracy for correctly predicting the presence of tumors with 11 C-methionine PET scans were 100% (95% CI, not applicable), 60% (95% CI, 0%-100%), and 93% (95% CI, 70%-96%), respectively, and the interobserver agreement was 100% (Cohen k 5 1). Positive 11 C-methionine PET readings had higher sensitivity, specificity, and accuracy for correctly predicting the presence of tumors than did individual MRI readings. 11 C-methionine PET also had higher sensitivity and accuracy for correctly predicting the presence of tumors than did the consensus MRI readings. The consensus MRI and 11 C-methionine PET readings were concordant in 88.9% of cases and discordant in 11.1%. In 1 subject, there was significant discrepancy between the MRI abnormality and the PET abnormality; in this subject, there were considerable surgery-related MRI abnormalities because the scans were obtained 21 d after surgery (Fig. 1) . We tested the accuracy between MRI observer 1, MRI observer 2, MRI consensus reads, and 11 C-methionine PET reads in pairs with McNemar tests. There were no significant differences for any pair in the comparisons. In 5 of the 27 lesions, a discrepancy occurred between MRI observer 1, MRI observer 2, or the consensus MRI read for correctly predicting the final outcome, but 11 C-methionine PET correctly predicted the final outcomes in all these cases. The final outcome of 3 of these 5 lesions was presence of tumor, and the final outcome of 2 of these lesions was pseudoprogression. Only 1 case was indecisive for changes related to tumor treatment versus changes not related to tumor treatment in the consensus MRI interpretation but was correctly predicted by the 11 C-methionine PET evaluation (Fig. 2) . The receiver-operating-characteristic curves for SUV max , metabolic tumor volume, TBR max , TBR mean , T1-enhancing tumor volume, and abnormal tumor volume by FLAIR were assessed for their ability to predict the final outcomes (32) . The optimal SUV max cutoff to differentiate between the presence and absence of tumors was 3.3, with sensitivity, specificity, and accuracy of 60% (95% CI, 36%-78%), 100% (95% CI, not applicable), and 67% (95% CI, 44%-81%), respectively. The optimal metabolic tumor volume cutoff was 0.98 cm 3 , with sensitivity, specificity, and accuracy of 90% (95% CI, 69%-100%), 80% (95% CI, 0%-100%), and 89% (95% CI, 64%-96%), respectively. The optimal TBR max cutoff was 1.82, with sensitivity, specificity, and accuracy of 77% (95% CI, 55%-91%), 100% (95% CI, not applicable), and 81% (95% CI, 59%-89%), respectively. The optimal TBR mean cutoff was 1.4, with sensitivity, specificity, and accuracy of 72% (95% CI, 50%-88%), 40% (95% CI, 0%-100%), and 67% (95% CI, 44%-78%), respectively. The optimal T1-enhancing volume cutoff was 2.4 cm 3 or greater, with sensitivity, specificity, and accuracy of 73% (95% CI, 50%-88%), 80% (95% CI, 0%-100%), and 74% (95% CI, 52%, 85%), respectively. The optimal abnormal FLAIR volume cutoff was 13.76 cm 3 , with sensitivity, specificity, and accuracy of 86% (95% CI, 64%-96%), 80% (95% CI, 0%-100%), and 85% (95% CI, 63%-93%), respectively. The details are summarized in Table 2 . There is minimum uptake at anteromedial surgical margin (arrowhead). This area was not included in metabolic tumor volume because of low SUV (lower than 1.3 times that of contralateral frontal lobe cortex). We used the optimized cutoffs to categorize imaging features, including the T1-enhancing volume, FLAIR volume, SUV max , metabolic tumor volume, and TBR. T1-enhancing tumor volume, metabolic tumor volume, and TBR were significant by themselves for predicting the final outcome. However, the association of final outcome with quantitative imaging parameters was not significant when tested with multivariable analysis. Log-rank tests were performed to test whether these imaging features are associated with OS. Using the cutoffs determined by receiver-operatingcharacteristic curves, we found that OS was significantly associated with metabolic tumor volume (P 5 0.0074), TBR max (P 5 0.027), and T1-enhancing volume (P 5 0.016) (Figs. 3 and 4) . However, SUV max , TBR mean , and FLAIR volume did not show a significant association with OS. Differentiating true tumor progression from treatment-related effects can be challenging because of overlapping features (11, 19, 25) . Many advanced MRI techniques and molecular imaging techniques have been studied to address this challenge (19, 25) . Recent evidence suggests that amino acid PET tracers (i.e., 18 F-dihydroxyphenylalanine PET and 18 F-FET PET) can assist conventional MRI at correctly identifying surgical margins and distinguishing between tumoral and nontumoral changes (15, (33) (34) (35) (36) . 11 C-methionine PET, in particular, has shown substantial promise (37) (38) (39) (40) , but these studies were performed only on adults, and many included metastatic nonprimary CNS tumors. Therefore, we explored the role of 11 C-methionine PET in evaluating only recurrent PHGGs. The 11 C-methionine uptake is directly related to L-type amino acid transporter 1 expression (41); high 11 C-methionine uptake characteristically occurs in tumors with a high degree of neoangiogenesis and cellular proliferation (8, 41) . Previous studies have found 11 C-methionine PET to have high sensitivity and specificity for diagnosing high-grade tumors (8, 42) . In our study, we found that the sensitivity and accuracy of 11 C-methionine PET for correctly differentiating true tumor progression from treatment-related effects were 100% and 93%, respectively, compared with the reported 70%-80% sensitivity and 75% accuracy in previous studies (37, 38, 40) . This difference may be due to the heterogeneous samples in the previous studies, which included both metastases and gliomas that were treated with different radiation doses and chemotherapy regimens. However, the sensitivity and specificity of the 11 C-methionine PET for differentiating tumor progression from treatment-related effects in our study were similar to the FIGURE 2. (A) Axial T2-weighted FLAIR image through level of midbrain shows large cystic resection cavity in left temporal lobe (white arrow). There is ill-defined T2 abnormality at medial aspect of resection cavity (black arrow). No obvious abnormality is noted posterior and lateral to resection cavity (arrowhead). (B) Axial postcontrast T1-weighted image through same level better shows focal area of contrast enhancement (arrow). This enhancing focus has been followed up since prior treatment. Subtle contrast enhancement, new finding compared with previous MRIs, is noted posterior and lateral to resection cavity (arrowhead). (C) Axial reconstruction of 11 C-methionine PET images through same level shows intense 11 C-methionine uptake posterior and lateral to resection cavity (arrowhead) corresponding to new subtle T1 enhancement. (D) Postcontrast T1-weighted 11 C-methionine PET/MRI image also shows that 11 C-methionine abnormality corresponds to new subtle enhancement at posterior and lateral aspect of resection cavity (arrowhead). results of a study by Dunkl et al. (43) . Our study also found the quantitative PET evaluation to have higher specificity than qualitative evaluation. This is in contrast to a study by Minamimoto et al. (37) , which found no significant difference between qualitative and quantitative 11 C-methionine PET evaluations for assessment of tumor progression. More recently, a study by Marner et al. also found 18 F-FET PET to have high specificity and accuracy for differentiating tumor from nontumor lesions (44) . Qualitative interpretation of MRI findings is the standard of care for follow-up of high-grade gliomas after treatment (19) . Unlike qualitative 11 C-methionine PET assessments, qualitative interpretation of MRI findings involves careful evaluation of many different MRI sequences that exploit the different magnetic properties of tissues and changes in these magnetic properties with MRI contrast compounds. This multifactorial evaluation process inherently leads to interpretation bias, as we observed in our study. The sensitivity, specificity, and accuracy of the 2 MRI observers in our study significantly differed, although both observers had expertise in evaluating pediatric brain tumors for 10 y or more. Such interpretation bias influences the diagnostic performance of MRI; indeed, we found that the consensus MRI interpretation performed significantly better, similar to that of 11 C-methionine PET, than did the individual MRI readings. Because consensus MRI interpretations by multiple neuroradiologists are not practical in routine clinical practice, the addition of 11 C-methionine PET imaging for suggestive MRI findings adds value to the overall care of patients with PHGGs. Our study demonstrated a significant association of metabolic tumor volume and TBR max with OS, as previously described (45, 46) . Additionally, postcontrast T1-enhancing volume was also significantly associated with OS, similar to multiple prior studies (47, 48) . Our study included limitations. The sample size was small but relatively large, considering the rarity of this tumor. As this study was initiated in 2009, the acquisition time of our PET scan was set to 15 min instead of the currently recommended 20 min. In addition, the criteria for performing 11 C-methionine PET on the included patients were based on a high clinical suspicion for recurrence or a high likelihood of tumor recurrence on MRI findings. Consequently, there was a high pretest probability that the MRI abnormalities would represent tumor recurrence, thereby introducing selection bias. A larger prospective multiinstitutional study with regularly scheduled 11 C-methionine PET scans might alleviate such selection bias. These studies should be sufficiently powered to examine whether 11 C-methionine PET SUV max cutoffs and qualitative interpretations can quantitatively predict final outcomes. However, because of the short half-life of 11 C (20 min), 11 C-methionine is currently available only at institutions with access to a cyclotron; such a study would need to be restricted to centers with 11 C-methioninesynthesizing capability or institutions able to refer patients with suggestive findings on MRI to a center with 11 C-methioninesynthesizing capability. To mitigate this problem, 18 F-FET PET with a longer half-life is increasingly used in assessments of gliomas in many countries (49) (50) (51) (52) . CONCLUSION Our study showed that 11 C-methionine PET has slightly higher sensitivity, specificity, and accuracy for correctly predicting the presence of tumor recurrence than does MRI when new or worsening imaging abnormalities are detected during surveillance of previously treated PHGG. The interobserver agreement on interpretation for 11 C-methionine PET findings was excellent and better than that of MRI. Our study also showed that quantitative 11 C-methionine PET and MRI can also predict OS. These findings indicate that 11 C-methionine PET imaging may add value for predicting PHGG recurrence. However, the results from this small cohort should be validated in larger prospective, preferably multiinstitutional studies. Melissa Wing worked on this project as a trainee in the Pediatric Oncologic Education (POE) project, funded by the National Institutes of Health (R25CA23944). Additionally, this work was supported in part by the American Lebanese Syrian Associated Charities (ALSAC). Asim Bag received an honorarium from ABC MedED, LLC, for MRI protocol optimization consulting. No other potential conflict of interest relevant to this article was reported. QUESTION: How does the diagnostic performance of 11 C-methionine PET compare with that of MRI for predicting tumors in lesions suggestive of recurrence during follow-up of PHGGs? PERTINENT FINDINGS: 11 C-methionine PET had 100% sensitivity, 60% specificity, and 93% accuracy for correctly predicting the presence of tumors in new or worsening MRI abnormalities suggestive of tumors, in contrast to 95%, 60%, and 89%, respectively, for qualitative MRI interpretation. The interobserver agreement for 11 C-methionine PET was higher than that for MRI. IMPLICATIONS FOR PATIENT CARE: 11 C-methionine PET is a modality complementary to MRI for evaluating lesions suggestive of recurrence in previously treated PHGG. Pediatric brain tumors: innovative genomic information is transforming the diagnostic and clinical landscape WHO grade has no prognostic value in the pediatric high-grade glioma included in the HERBY trial Advances in the molecular genetics of gliomas: implications for classification and therapy Pediatric high grade glioma: a review and update on tumor clinical characteristics and biology Intensive chemotherapy improves survival in pediatric high-grade glioma after gross total resection: results of the HIT-GBM-C protocol Prospective evaluation of local control and late effects of conformal radiation therapy in children, adolescents, and young adults with high-grade glioma Survival outcomes in pediatric recurrent high-grade glioma: results of a 20-year systematic review and meta-analysis The value of 11 C-methionine PET in the early differentiation between tumour recurrence and radionecrosis in patients treated for a high-grade glioma and indeterminate MRI Treatment-induced brain tissue necrosis: a clinical challenge in neuro-oncology Pseudoprogression: fact or wishful thinking in neurooncology? Clinical features, mechanisms, and management of pseudoprogression in malignant gliomas Pseudoprogression in children, adolescents and young adults with non-brainstem high grade glioma and diffuse intrinsic pontine glioma Advances in neuro-oncology imaging Advanced MRI and PET imaging for assessment of treatment response in patients with gliomas Diagnosis of pseudoprogression in patients with glioblastoma using O-(2-[ 18 F]fluoroethyl)-L-tyrosine PET Differentiation of true progression from pseudoprogression in glioblastoma treated with radiation therapy and concomitant temozolomide: comparison study of standard and high-b-value diffusion-weighted imaging Reevaluating the imaging definition of tumor progression: perfusion MRI quantifies recurrent glioblastoma tumor fraction, pseudoprogression, and radiation necrosis to predict survival Multicenter study demonstrates radiomic features derived from magnetic resonance perfusion images identify pseudoprogression in glioblastoma Pseudoprogression, radionecrosis, inflammation or true tumor progression? Challenges associated with glioblastoma response assessment in an evolving therapeutic landscape The use of 18 F-FDG PET to differentiate progressive disease from treatment induced necrosis in high grade glioma 18 F-FET PET imaging in differentiating glioma progression from treatment-related changes: a single-center experience 11 C-methionine-PET for differentiating recurrent brain tumor from radiation necrosis: radiomics approach with random forest classifier Comparison of MRI, F-18 FDG, and 11 C-choline PET/CT for their potentials in differentiating brain tumor recurrence from brain tumor necrosis following radiotherapy Differentiating radiation necrosis from tumor recurrence in high-grade gliomas: assessing the efficacy of 18 F-FDG PET, 11 C-methionine PET and perfusion MRI Response Assessment in Neuro-Oncology working group and European Association for Neuro-Oncology recommendations for the clinical use of PET imaging in gliomas Comparison of 11 C-methionine, 11 C-choline, and 18 F-fluorodeoxyglucose-PET for distinguishing glioma recurrence from radiation necrosis 11 C-methionine positron emission tomography delineates non-contrast enhancing tumor regions at high risk for recurrence in pediatric high-grade glioma Synthesis of L-[methyl-11 C] methionine ( 11 C-MET) Joint EANM/EANO/RANO practice guidelines/ SNMMI procedure standards for imaging of gliomas using PET with radiolabelled amino acids and [ 18 F]FDG: version 1.0 Updated response assessment criteria for high-grade gliomas: Response Assessment in Neuro-Oncology working group The measurement of observer agreement for categorical data Strategies for graphical threshold determination The use of dynamic O-(2-18 F-fluoroethyl)-Ltyrosine PET in the diagnosis of patients with progressive and recurrent glioma Comparison of visual and semiquantitative analysis of 18 F-FDOPA-PET/CT for recurrence detection in glioblastoma patients Late pseudoprogression in glioblastoma: diagnostic value of dynamic O-(2-[ 18 F]fluoroethyl)-L-Tyrosine PET Clinical impact of integrating positron emission tomography during surgery in 85 children with brain tumors Differentiation of brain tumor recurrence from post-radiotherapy necrosis with 11 C-methionine PET: visual assessment versus quantitative assessment Diagnostic accuracy of PET for recurrent glioma diagnosis: a meta-analysis C-methionine PET (Met-PET) for a diagnosis algorithm for pseudoprogression (PsP), radiations necrosis (RN) and progression (P) after an indeterminate magnetic resonance imaging (MRI) Diagnostic accuracy of 11 C-methionine PET for differentiation of recurrent brain tumors from radiation necrosis after radiotherapy Correlation of L-methyl-11 C-methionine (MET) uptake with L-type amino acid transporter 1 in human gliomas An interindividual comparison of O-(2-[ 18 F]fluoroethyl)-L-tyrosine (FET)-and L-[methyl-11 C]methionine (MET)-PET in patients with brain gliomas and metastases The usefulness of dynamic O-(2-18 F-fluoroethyl)-L-tyrosine PET in the clinical evaluation of brain tumors in children and adolescents Diagnostic accuracy and clinical impact of [ 18 F]FET PET in childhood CNS tumors Prognostic value of 11 C-methionine PET in patients with IDH wild-type glioma Prediction of recurrence and survival analysis after radiotherapy of glioblastoma using 11 C-methionine PET/CT and MR Recurrent glioblastoma: volumetric assessment and stratification of patient survival with early posttreatment magnetic resonance imaging in patients treated with bevacizumab Recurrent glioblastoma treated with bevacizumab: contrast-enhanced T1-weighted subtraction maps improve tumor delineation and aid prediction of survival in a multicenter clinical trial FET PET in the evaluation of indeterminate brain lesions on MRI: differentiating glioma from other non-neoplastic causes-a pilot study Glioma recurrence versus radiation necrosis: single-session multiparametric approach using simultaneous O-(2-18 F-fluoroethyl)-L-tyrosine PET/MRI Comparison of 3 9 -deoxy-3 9 -[ 18 F]fluorothymidine PET and O-(2-[ 18 F]fluoroethyl)-L-tyrosine PET in patients with newly diagnosed glioma Simultaneous FET-PET and contrast-enhanced MRI based on hybrid PET/MR improves delineation of tumor spatial biodistribution in gliomas: a biopsy validation study We thank Amy Vavere, PhD, for production of 11 C-methionine. We also thank Mitrea Bogdan, PhD, for help in image segmentation and Nisha Badders, PhD, for help in copyediting.