key: cord-0030948-82l9p71v authors: Hallan, David R; Rizk, Elias title: Ventriculoperitoneal Shunt and Gastrostomy Tube Placement and Timing: A Database Analysis date: 2022-04-03 journal: nan DOI: 10.7759/cureus.23776 sha: ed1bdec81da85387fefb4f49f65a51a02dfa430a doc_id: 30948 cord_uid: 82l9p71v Background Debate exists about the safety of ventriculoperitoneal shunt placement in the presence of a gastrostomy tube and the timing of these procedures from each other. Using a large database, we sought to determine the rates of shunt infection and revision in patients who had both devices placed, based on the timing between procedures. Methods We performed a retrospective database analysis using a multi-institutional database (TriNetX), looking at all patients diagnosed with gastrostomy tube with subsequent ventriculoperitoneal shunt placement and vice-versa. We also evaluated patients who had gastrostomy tubes and shunts placed at the same time. We categorized cohorts into patients with device placement after 1-10 days, 11-30 days, and after one month of the other. Our primary endpoints were shunt infection and shunt revision. Results Patients who had same-day gastrostomy tube and shunt placement had a shunt infection rate of 10.06% within five years, and 14.53% had a shunt revision. With prior shunting and subsequent gastrostomy tube placement within 1-10 days, 12.18% had shunt infections, and 17.88% had shunt revisions; for those who had subsequent gastrostomy tube placement within 11-30 days, shunt infections were seen in 10.57%, and shunt revisions in 19.41%; gastrostomy tube placement after one month or longer of shunt placement resulted in 15.39% of patients having shunt infections and 17.73% with shunt revision. Prior gastrostomy tube patients with subsequent shunt placement, within 1-10 days had shunt infection rates of 8.27% and revision rates of 14.39%; for shunt placement within 11-30 days, shunt infections were seen in 10.82%, and shunt revisions were done in 14.33% of patients; for shunt placement after one month or longer, shunt infection rate was 11.68%, and revision rate was 16.80%. Conclusions Our results demonstrate no significant difference in shunt infection rates and shunt revision rates between same-day gastrostomy tube and shunt placement versus placement within 1-10 days, 11-30 days, or any time after one month from one another. Patients with neurologic injury requiring a ventriculoperitoneal shunt (VPS) often also require gastrostomy tube (G-tube) placement for nutritional support. Likewise, patients with neurologic injury requiring a G-tube for nutritional support may also have hydrocephalus requiring a VPS [1] . However, there is debate about the safety of ventriculoperitoneal shunt placement in the presence of a gastrostomy tube, and vice-versa, and the timing of such procedures from each other. The discourse stands on the risk of shunt malfunction and shunt infection with bacterial pathogens related to a G-tube [1] [2] [3] [4] [5] [6] . Therefore, we sought to determine the shunt infection rates and shunt revision in patients who had both devices placed, based on the timing between procedures, using a large database. This was a retrospective comparative case-control study. We used a de-identified database network (TriNetX) to retrospectively query via ICD-10 and current procedural terminology codes to evaluate all patients with a prior G-tube placement with subsequent VPS placement, as well as patients with a prior VPS with subsequent G-tube placement. We also evaluated patients who had G-tubes and VPS placed at the same time. We categorized placement into cohorts for those patients who had device placement after 1-10 days, 1 1 11-30 days, and after one month of the other. Data were obtained from 62 health care organizations (HCOs) spanning 11 countries. The database includes variables on demographics, diagnoses, medications, laboratory values, genomics, and procedures. The identity of the HCOs and patients is not disclosed to comply with ethical guidelines regarding data re-identification. Because of the database's federated nature, an IRB waiver has been granted. Our use of this database and its validity has been disclosed by previous literature, and exact details of the network have been previously described [7] [8] [9] [10] . The medical information included age at the initial procedure (index) date, as well as sex, race, and comorbidities of hypertension, acute kidney injury, diabetes, ischemic heart disease, heart failure, atrial fibrillation, disorders of lipoprotein metabolism disorders, and other dyslipidemias, obesity, history of nicotine dependence, chronic respiratory disease, cirrhosis, alcohol abuse or dependence, and peripheral vascular disease, recorded up to the date of the index date. Our primary outcomes of interest were shunt infection and shunt revision rates. These outcomes were obtained over five years. Chi-square analysis was performed on categorical variables. Comparisons were made between same-day G-tube and shunt versus each cohort. We identified 4,269 patients with a VPS and G-tube. In addition, 179 (4.19%) patients had a VPS and G-tube placed the same day, 509 (11.92%) patients with a prior VPS and G-tube placement within 1-10 days, 814 (19.07%) within 11-30 days, and 897 (21.01%) with placement after one month. Thus, there were 278 (6.51%) patients with prior G-tube and placement of a VPS within 1-10 days, 342 (8.01%) within 11-30 days, and 1,250 (29.28%) with placement after one month. Baseline demographics and characteristics can be seen in Table 1 . Our results demonstrate no significant difference in VPS infection rates and VPS revision rates between same-day G-tube and VPS placement versus placement within 1-10 days, 11-30 days, or any other time after one month from one another. While previous studies have shown a VPS infection rate of 0-30%, our study shows an infection rate of 8.27%-15.39% within five years [1] [2] [3] [4] [5] [6] . VPS revision rates ranged from 14.33% to 19.41% within five years of follow-up. In 2020 Tyler et al. published a retrospective analysis looking at G-tube placement and VPS placement within the same hospitalization. They found a VPS infection rate in three out of 45 patients (7%) [5] . In 2017 Oterdoom et al. published a systematic review of VPS and G-tube placement. They found nine relevant studies and overall found VPS infections in 26 out of 208 patients (12.5%). In addition, 137 out of 208 patients had VPS before G-tube placement, with a VPS infection rate of 4.4%; 55 patients had G-tube placement before VPS, with a resulting infection rate of 21.8%; 16 patients had G-tube and VPS placement during the same day, and the infection rate was 50%. The authors concluded that G-tube placement ideally occurs before VPS placement but that having a VPS is not a contraindication to G-tube placement [2] . [3] . A year before this study, Schulman et al. published a retrospective single-center study of 39 patients with VPS who eventually required a G-tube. The time interval between VPS and G-tube placement was 2 to 564 days. Only two (5%) patients developed meningitis, which was at the 2-and 15-month mark after G-tube placement [4] . A 2021 systematic review of G-tube and VPS placement in the pediatric population by Gerges et al. found four studies involving the timing of VPS and G-tube placement, which reported inconclusive results, with some study patients having no infections with the concomitant placement of both devices, and other studies showing increased risk of shunt infection with prior G-tube placement [11] [12] [13] [14] [15] . The major limitation of this study was its retrospective design for data obtention. Furthermore, due to the nature of the database, we were unable to collect patient-level data. Another limitation of this study was the unavailability of radiological images and reports. Also, the diagnostic protocol and tests performed to assess diagnoses were unavailable in the database we utilized/employed. In addition, some misidentification is inevitable in database studies. In this large database retrospective study, we approached the inconclusive timing between VPS and G-tube placement related to device-related and device-placement infection rates. Our results conclude that there is no significant difference in VPS infection rates or VPS revision rates between same-day G-tube and VPS placement versus placement within 1-10 days, 11-30 days, or any other time after one month from one another. This suggests that these procedures are safe to perform concurrently and that either procedure may not limit the timing of the other. Human subjects: Consent was obtained or waived by all participants in this study. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work. Is percutaneous endoscopic gastrostomy tube placement safe in patients with ventriculoperitoneal shunts? Systematic review of ventricular peritoneal shunt and percutaneous endoscopic gastrostomy: a safe combination Placement of gastrostomy tubes in patients with ventriculoperitoneal shunts does not result in increased incidence of shunt infection or decreased survival The safety of percutaneous endoscopic gastrostomy tube placement in patients with existing ventriculoperitoneal shunts Risk of ventriculoperitoneal shunt infection with coexisting percutaneous endoscopic gastrostomy tube and associated factors Percutaneous endoscopic gastrostomy and ventriculoperitoneal shunts: a dangerous combination Cerebral venous thrombosis and portal vein thrombosis: a retrospective cohort study of 537,913 COVID-19 cases. EClinicalMedicine. 2021 Outcomes of COVID-19 in patients with rheumatoid arthritis: a multicenter research network study in the United States 6-month neurological and psychiatric outcomes in 236 379 survivors of COVID-19: a retrospective cohort study using electronic health records Using a federated network of real-world data to optimize clinical trials operations Evaluation of risk of gastrostomy and ventriculoperitoneal shunt placement in pediatric patients: a systematic review of the literature Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts Complications of video-assisted gastrostomy in children with or without a ventriculoperitoneal shunt Risk of ventriculoperitoneal shunt infections due to gastrostomy feeding tube insertion in pediatric patients with brain tumors Infectious risk to ventriculo-peritoneal shunts from gastrointestinal surgery in the pediatric population