key: cord-0030591-tprxvzy1 authors: Di Molfetta, S.; Patruno, P.; Cormio, S.; Cignarelli, A.; Paleari, R.; Mosca, A.; Lamacchia, O.; De Cosmo, S.; Massa, M.; Natalicchio, A.; Perrini, S.; Laviola, L.; Giorgino, F. title: A telemedicine-based approach with real-time transmission of blood glucose data improves metabolic control in insulin-treated diabetes: the DIAMONDS randomized clinical trial date: 2022-04-27 journal: J Endocrinol Invest DOI: 10.1007/s40618-022-01802-w sha: 84c6555951e5b611231c34583bfb85739f5f257e doc_id: 30591 cord_uid: tprxvzy1 PURPOSE: To evaluate if a web-based telemedicine system (the Glucoonline(®) system) is effective to improve glucose control in insulin-treated patients with type 1 and type 2 diabetes, as compared to standard of care. METHODS: This was a prospective, randomized, controlled trial, carried out at three tertiary referral centers for diabetes in Italy. Adults with insulin-treated type 1 and type 2 diabetes, inadequate glycemic control, and no severe diabetes-related complications and/or comorbidities were eligible for this study. Patients were randomized to either perform telemedicine-assisted (Group A) or standard (Group B) self-monitoring blood glucose (SMBG) for 6 months. In Group A, patients received prompt feedback about their blood glucose levels and therapy suggestions from the study staff via phone/SMS, when appropriate. In Group B, patients had no remote assistance from the study staff between planned visits. RESULTS: 123 patients were included in the final analysis. After 6 months, patients achieved a significant reduction in HbA1c in Group A (−0.38%, p < 0.05) but not in Group B (+ 0.08%, p = 0.53). A significant difference in the percentage of patients with HbA1c < 7% between Group A and Group B was found after 3 months (28.6% vs 11.1%, p = 0.02). Also, fewer patients (p < 0.05) with HbA1c > 8.5% were found in Group A vs Group B, respectively, after both 3 months (14.3% vs 35.2%) and 6 months (21.8% vs 42.9%). CONCLUSIONS: The use of the Glucoonline™ system resulted in improved metabolic control. Telemedicine services have potential to support diabetes self-management and provide the patients with remote, prompt assistance using affordable technological equipment. Trial registration This study was registered at clinicaltrials.gov (NCT01804803) on March 5, 2013. Self-monitoring of blood glucose (SMBG) is a cornerstone of diabetes management, as it may help detect the effects of glucose-lowering therapies and patient lifestyle on individual blood glucose (BG) levels [1] [2] [3] . International guidelines recommend individualized SMBG frequency based on multiple factors, including type of diabetes, treatment regimen (i.e., lifestyle intervention, non-insulin oral and injectable agents, or insulin), quality of glycemic control, risk of hypoglycemia, and patient's willingness to self-test [4, 5] . Accordingly, most patients using intensive insulin therapy (multiple daily injections or insulin pump therapy) are required to check their BG at least 3-4 times daily [6] . However, to fully exploit SMBG and achieve glucose targets, SMBG should be performed in a structured manner (e.g., before meals and snacks, at bedtime, occasionally postprandially, before exercise, when hypoglycemia is suspected, before driving, etc.), and the results need to be accurately interpreted and used to guide adjustments in medications, especially insulin, and to modify food intake and/or physical activity [7, 8] . Nevertheless, a substantial proportion of patients who report checking their BG at least once daily also report taking no action when results show high or low values [9] . We have developed a novel system [Glucoonline ® , 2011], comprised of a smartphone-connectable glucose meter, a software-implemented smartphone for real-time BG data transmission, and a Decision Support Software (DSS)assisted remote server performing comprehensive data analysis, and providing prompt feedback to the patient and the health care provider (HCP) through predefined algorithms. Also, the system could help to implement multiple aspects of diabetes management, including assessment and enhancement of patients' adherence to the recommended SMBG scheme, HCP's evaluation of overall glucose control, detection of actual/impending hyper-and/or hypoglycemic events, and promptness of intervention in case of emergency situations. The feasibility of such a system for clinical use was preliminarly evaluated over a 3-month period in a pilot study enrolling 10 individuals with type 1 diabetes on multiple daily insulin injections (data on file). The main aim of this study was to investigate if the webbased Glucoonline ® system is effective in improving overall glucose control, determined by measuring HbA1c levels, in insulin-treated patients with type 1 and type 2 diabetes, as compared to standard of care. This was a prospective, randomized, controlled trial, recruiting patients from 3 sites ( Patients had to meet the following inclusion criteria: males and females; age 18-70 years; insulin-treated diabetes (both type 1 and type 2 diabetes treated with at least 3 injections/ day regardless of type of insulin); diagnosis of diabetes from at least 1 year; inadequate glycemic control (HbA1c ranging from 7.0% to 10.0%; local measurements within the last 6 weeks); ability and willingness to carry out SMBG; informed consent. Major exclusion criteria were: established and impending complications of diabetes, such as proliferative retinopathy or maculopathy (with significant loss of visual function), severe renal failure (eGFR < 30 ml/min/ m 2 ), severe neuropathy (autonomic dysfunction, peripheral neuropathy, gastroparesis); clinically significant, active (over the past 12 months) disease of the cardiovascular, gastrointestinal, neurological, genito-urinary, or hematological systems; severe uncontrolled hypertension (systolic blood pressure > 180 mmHg; diastolic blood pressure > 100 mmHg); diagnosis of active neoplasia within the last 5 years (or history of chemotherapy/radiation-treated malignancy within 5 years prior to study procedure, except for lymphoma); pregnancy or intention to become pregnant during the study; any other concomitant medical or psychological condition which, in the judgment of the investigator, could make the patient unsuitable for study participation. All patients were instructed to perform SMBG according to the national Italian guidelines (4 SMBG tests per day or more in case of metabolic derangement) [10] and adjust insulin doses based on measured glucose readings. The recommended SMBG scheme included testing in the fasting state, before and 2 h after breakfast and/or lunch, and/or dinner, and 3-5 h after lunch or dinner (absorptive phase). Randomization was carried out in a 1:1 manner using a web-based application, and stratified by age, sex, type of diabetes, and HbA1c level (≤ 8.5%, > 8.5%). The study design is illustrated in Fig. 1 . Patients in Group A were given a smartphone-connectable meter (OneTouchPro Verio, Lifescan, modified for USB cable connection to smartphone) and a software-implemented smartphone for real-time data transmission. Wireless connectivity between the smartphone and the remote server was enabled, ensuring a bidirectional data flow. Also, a web-based electronic CRF (Glucoonline™ eCRF) was created, allowing for multiple assessments: (i) appropriateness of SMBG frequency; (ii) overall glucose control quality; (iii) graphical visualization of BG values according to meals and time of the day; (iv) absolute number and percentage of BG values < 70 mg/dl, < 50 mg/dl and < 30 mg/dl; (v) absolute number and percentage of BG values > 180 mg/dl, > 250 mg/dl, and > 350 mg/dl; (vi) the low blood glucose index (LBGI), high blood glucose index (HBGI), and Average Daily Risk Range (ADRR) developed by Kovatchev et al. [11] [12] [13] . Patients in Group B were given a regular glucose meter (OneTouchPro Verio, Lifescan) and were asked to report their glucose levels on a paper diary. At the first visit (V1), patients in Group A underwent an additional educational session to learn how to use the meter and transmit BG data, log into their personal Glucoon-line™ eCRF and access meaningful information about their glucose control, interpret their glucose patterns, and refer themselves to the medical staff irrespective of the planned study visits when needed. After V1, all patients had two follow-up visits with a 3-month interval (V2 and V3). In the intervention arm, investigators regularly checked the Glu-coonline™ eCRF throughout the study period; also, they received an alert by the DSS-supported server every time an individual patient (i) was performing SMBG sub-optimally (e.g., infrequent or temporally inadequate testing), (ii) had displayed BG values beyond thresholds set for hypoglycemia/hyperglycemia, and (iii) had experienced recurrent hypoglycemia or sustained hyperglycemia. Under these conditions, irrespective of the planned study visits, investigators could make prompt interventions, including patient counseling via phone/SMS, or arrange for a medical visit. Specific interventions could be implemented if patients had SMBG values < 40 mg/dl. In the control arm (Group B), patients received no feedback about their BG levels from the study staff between planned visits, nor instructions on how to modify their therapy. Also, they had no remote assistance in case of emergency situations. At V2 and V3, the medical personnel could make insulin dose and other therapy adjustments according to their clinical judgement. At each study visit, patients underwent comprehensive physical examination and had blood samples collected for HbA1c, fasting glucose (FPG), creatinine, and lipid profile measurements. The HbA1c measurements were performed by HPLC. The Bio-Rad Variant II system (Bio-Rad Laboratories, Segrate, Italy) was used in sites No. 1 and 3 and the Tosoh G8 (Tosoh Bioscience, Torino, Italy) in site No. 2. The analytical performances of the local laboratories during the whole study were evaluated based on their internal quality control (IQC) results and from the participation to the External Quality Assessment (EQAS) programs. The primary endpoint was change in HbA1c from V1 assessed at V3 (6 months). Also, differences in the following secondary endpoints were evaluated: change in HbA1c from V1 assessed at V2 (3 months), proportion of patients with HbA1c > 8.5%, < 7.0% or < 6.5%; frequency of BG testing; conformity with recommended SMBG scheme; fasting BG (FBG); postprandial BG (PPBG); post/preprandial BG excursion (PPBGE); SMBG-derived indices of overall glycemic control and variability; frequency of hypoglycemic episodes. Conformity with recommended SMBG scheme was defined as the ratio of days with appropriate BG testing to the total days and expressed as percentage of days. The sample size was calculated based on a previous study [14] evaluating the efficacy of a telemonitoring intervention, coupled with active medication management, in reducing HbA1c, as compared with the control group. Accordingly, it was established that at least 88 patients (44 per group) convenƟonal care based on SMBG ≥4 glucose tests/day «hot» glucometer + web-based access to glucose data + DSS-iniƟated instant feedback + 24 h access to medical team 0 24 EducaƟon Treatment period Lead-in were needed to find a difference with a power of 80% and significance level of 5%. Continuous variables are expressed as mean ± standard deviation and categorical variables as count (percentage). A twotailed paired Student's t-test and a chi-square test were run to test for differences in continuous and categorical variables, respectively. An ANOVA test was run to check differences in SMBG data at different time points. The Shapiro-Wilk test was used to assess for data normality. All statistical analyses and data processing were performed using SPSS ® Software (version 19, IBM). A two-sided p-value < 0.05 was regarded as statistically significant. The study started in September 2013 and ended in November 2017. Procedures and devices were kept identical throughout this time frame. The total number of patients evaluated in the study was 211, of which 123 were included in the final analysis and 97 completed the 6-month follow-up period (Fig. 2) . Most common reasons for declining participation in the trial were poor compliance with self-testing of blood glucose and/or unwillingness to be engaged in an intensive monitoring program involving use of smartphone and device. Patients randomized to either Group A or Group B did not show significant clinical or biochemical differences at baseline ( Table 1) . At V3, patients achieved a significant reduction in HbA1c level compared to baseline in Group A (0.38% versus V1, p < 0.05, paired t-test) but not in Group B (+ 0.08% versus V1, p = 0.5345, paired t-test) (Fig. 3 ). A higher percentage of patients with HbA1c < 7% was observed in Group A than in Group B at V2 (p = 0.022, χ 2 test). Also, fewer patients with HbA1c > 8.5% were found at both V2 (p = 0.011, χ 2 test) and V3 (p = 0.026, χ 2 test) in Group A versus Group B (Fig. 4) . In patients randomized to Group A, SMBG-derived indices were analyzed for the following periods: 14 days following V1 (T1), 14 days preceding V2 (T2), and 14 days preceding V3 (T3). No significant differences were observed in regard to mean BG, coefficient of variation, percentage of data in the 70-180 mg/dl range, percentage of data below the 70-180 mg/dl range, percentage of data above the 70-180 mg/dl range, fasting BG, postprandial BG, post/ pre-breakfast BG difference, post/pre-lunch BG difference, post/pre-dinner BG difference, number of BG values per day and conformity to recommended SMBG scheme ( Table 2 ). In group B, very few BG readings were available on paper diaries at T1; at T2 and T3, the testing frequency was 2.5 and 2.4 tests per day, respectively. In addition, no significant changes were observed in terms of body weight or waist circumference changes at V3 versus baseline in either Group A or Group B patients (data not shown). In patients with insulin-treated type 1 and type 2 diabetes the use of the Glucoonline™ system resulted in a 0.38% decrease in HbA1c from baseline and a higher proportion of patients achieving a HbA1c target level of less than 7%, as compared with standard of care. Of note, benefits were found already after a 3-month observation period and were maintained until study end. Thus, this telemonitoring system paired to a web-based DSS resulted in a both statistically and clinically significant improvement in metabolic control. In the intervention group, accurate BG reporting and enhanced data analysis through the web-based eCRF, together with the possibility to provide the patients with timely feedback for hyperglycemia management, may have resulted in better metabolic control, even though we could not document a clear improvement in either SMBG testing frequency or daily profiles. On the other hand, the Glucoonline™ system did not promote a reduction of body weight or waist circumference. There is growing evidence to support telemedicine as a valuable intervention to improve glucose control with reduction of HbA1c levels and diabetes-related adverse outcomes in patients with both type 1 and type 2 diabetes [15] . However, studies dealing with telemedicine facilities in diabetes management to date suffer from important and underappreciated pitfalls (e.g., small sample size, lack of controls, poor study design, lack of demonstration of a long-term benefit, etc.). Our study had an experimental design with active control group and a 6-month follow-up period; also, an adequate retention rate (> 80%) was achieved at study end. Nevertheless, this study has some limitations. First, no SMBG data were collected prior to study intervention, possibly preventing detection of potential intervention-related improvements in daily self-monitoring of glucose levels. Indeed, SMBG data indicate a relatively good glucose control since T1 with a percentage of readings in the glucose range 70-180 mg/dl of 67%. Second, we could not use central laboratory-data analysis. However, the intra-lab imprecision for HbA1c measured at the local laboratories, expressed as coefficient of variation, was between 1.1 and 5.0% in the normal HbA1c range (i.e., HbA1c level ranging from 5.1 to 5.7%), and between 0.8 and 3.8% in the elevated HbA1c range (i.e., HbA1c level ranging from 9.9 to 10.7%). Also, in years 2015-2017, the relative biases respect to the target values in the EQAS exercises were between 0.4 and 2.8% for site No. 1, and between 0.5 and 1.1% for site No. 2, thus proving that the methods were sufficiently aligned. Third, it was not possible to retrieve adequate information on SMBG-driven instant messaging, physician-to-participant contact frequency, and change in total insulin daily dose, which would all give further consistency to our results and provide potential additional interpretations of the findings. Fourth, the proportion of subjects with type 2 diabetes was numerically higher in group A as compared with group B, even though this difference did not reach statistical significance. As patients with type 2 diabetes may achieve larger HbA1c reductions with telemedicinebased interventions than patients with type 1 diabetes [15, 16] , this unbalance may have affected the results of the trial. Fifth, clinicians were not blinded to group allocation, thus a bias in the delivery of the intervention cannot be excluded. Two recent meta-analyses of randomized controlled trials have shown a mean difference of 0.48% and 0.37% for change in HbA1c with telemedicine interventions in patients with type 1 and type 2 diabetes, respectively [15, 16] . These findings are in line with our results, since HbA1c declined in the Glucoonline™-assisted intervention group but not in the control group, with a mean 0.46% difference in HbA1c between groups at study end. Evidence from the existing literature also supports the effectiveness of digital self-management interventions after 3-6 months [16] [17] [18] , with digital health education programs requiring a longer duration of the intervention period to obtain a significant reduction in HbA1c [19] . Regarding changes in body weight and/or composition, indeed previous studies found conflicting results, showing either some improvement [20] [21] [22] [23] or no difference [24, 25] with telediabetes services as compared to usual care. In our study, no change in body weight or waist circumference occurred in the interventions group; however, the Glucoonline™ system was not implemented to also track body weight measures and send support messages for changes in physical activity or diet, or for emphasizing potential weight loss. With the advances in technology and increased use of webbased applications, multiple telemedicine options are available to help the patients manage their diabetes and achieve improved treatment outcomes. Telemedicine may enable an active interaction between people with diabetes and healthcare professionals by encouraging adequate SMBG testing frequencies and modalities, making SMBG results available for analyses to assess the quality of glucose control and providing the patient with appropriate SMBG-driven therapy adjustments. Telemedicine also could allow to check updated SMBG data to detect emergency situations (e.g., severe hypoglycemia, persistent hyperglycemia) and assist the patient with timely interventions. Accordingly, telemedicine services are appropriate to support frail patients with a high risk of diabetes-related adverse complications and events [26, 27] . Furthermore, the recent outbreak of SARS-CoV-2 pandemic has legitimized telemedicine as a valuable solution to monitor and assist a large number of patients at their homes remotely, thus relieving patient flow to the outpatient clinics [28, 29] . Our study provides additional evidence of the benefits of telemedicine strategies in patients with insulin-treated diabetes and demonstrates for the first time that the combination of a smartphone-based BG transmission and a DSS-assisted feedback technology results in clinically relevant improvement in metabolic control. The use of the web-based Glucoonline™ system for 6 months resulted in improved glucose control in patients with insulin-treated type 1 and type 2 diabetes, as compared to standard of care. Telemedicine services have great potential to support diabetes self-management and provide remote, prompt assistance with affordable technological equipment. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus Glycemic control in diabetes mellitus: have changes in therapy made a difference? Prospective, randomized trial on intensive SMBG management added value in non-insulin-treated T2DM patients (PRISMA): a study to determine the effect of a structured SMBG intervention Glycemic targets. Sec 6 in standards of medical care in diabetes 2017 diabetes Standard italiani per la cura del diabete What do professionals recommend regarding the frequency of self-monitoring of blood glucose? effects of structured versus unstructured self-monitoring of blood glucose on glucose control in patients with non-insulin-treated type 2 diabetes: a meta-analysis of randomized controlled trials Results that matter: structured vs. unstructured self-monitoring of blood glucose in type 2 diabetes Patients who self-monitor blood glucose and their unused testing results Standard italiani per la cura del diabete mellito 2009-2010. Infomedica-Formazione & Informazione Medica Symmetrization of the blood glucose measurement scale and its applications Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index Evaluation of a newmeasure blood glucose variability in diabetes Active care management supported by home telemonitoring in veterans with type 2 diabetes: the DiaTel randomized controlled trial clinical effectiveness of telemedicine in diabetes mellitus: a meta-analysis of 42 randomized controlled trials Does telemedicine improve treatment outcomes for diabetes? A meta-analysis of results from 55 randomized controlled trials Telemedicine application in the care of diabetes patients: systematic review and meta-analysis Online social networking services in the management of patients with diabetes mellitus: systematic review and metaanalysis of randomised controlled trials The effectiveness of web-based tools for improving blood glucose control in patients with diabetes mellitus: a meta-analysis Telemedicine influence on the follow-up of type 2 diabetes patients Diabetes Interactive Diary: a new telemedicine system enabling flexible diet and insulin therapy while improving quality of life: an open-label, international, multicenter, randomized study An evaluation of Birmingham Own Health telephone care management service among patients with poorly controlled diabetes. A retrospective comparison with the General Practice Research Database Active assistance technology reduces glycosylated hemoglobin and weight in individuals with type 2 diabetes: results of a theory-based randomized trial TeleHealth improves diabetes selfmanagement in an underserved community: diabetes TeleCare Online disease management of diabetes: engaging and motivating patients online with enhanced resources-diabetes (EMPOWER-D), a randomized controlled trial The association of home-telehealth use and care coordination with improvement of functional and cognitive functioning in frail elderly men A systematic review of the benefits of home telecare for frail elderly people and those with long-term conditions Telemedicine for diabetes care in India during COVID19 pandemic and national lockdown period: Guidelines for physicians Emergenza Covid-19 Percorso visite ambulatoriali di controllo nei centri di Diabetologia (che già seguono la persona con diabete). www. sidit alia. it/ pdf/ coron avirus/ PDTA% 20Eme rgenza% 20COV ID% 20e% 20tel emedi cina_ 01_ 04_ 20 We gratefully acknowledge Dr. Francesca Di Serio (Clinic Pathology Unit, Polyclinic University Hospital, Bari, Italy), Prof. Gaetano Corso (Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy), and Dr. Lazzaro Di Mauro (Transfusion Medicine Department, IRCCS "Casa Sollievo della Sofferenza", San Giovanni Rotondo, Foggia, Italy) for having performed the HbA1c measurements and for having provided their IQC and EQAS data.Author contributions FG designed and supervised the study. PP, OL and SDC conducted the study. SC created the dataset. SDM, SC and AC conducted statistical analysis. SDM drafted the manuscript. All authors read, provided feedback, and approved the final manuscript. FG is the guarantor and takes responsibility for the contents of the article. Informed consent All participants provided informed consent for participation in the study.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp:// creat iveco mmons. org/ licen ses/ by/4. 0/