key: cord-0028551-pgxqoszx authors: Crapnell, Robert D.; Dempsey, Nina C.; Sigley, Evelyn; Tridente, Ascanio; Banks, Craig E. title: Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review date: 2022-03-12 journal: Mikrochim Acta DOI: 10.1007/s00604-022-05186-9 sha: 602785a1fe7c236da15983f785d0de593750f2cc doc_id: 28551 cord_uid: pgxqoszx Determination of specific cardiac biomarkers (CBs) during the diagnosis and management of adverse cardiovascular events such as acute myocardial infarction (AMI) has become commonplace in emergency department (ED), cardiology and many other ward settings. Cardiac troponins (cTnT and cTnI) and natriuretic peptides (BNP and NT-pro-BNP) are the preferred biomarkers in clinical practice for the diagnostic workup of AMI, acute coronary syndrome (ACS) and other types of myocardial ischaemia and heart failure (HF), while the roles and possible clinical applications of several other potential biomarkers continue to be evaluated and are the subject of several comprehensive reviews. The requirement for rapid, repeated testing of a small number of CBs in ED and cardiology patients has led to the development of point-of-care (PoC) technology to circumvent the need for remote and lengthy testing procedures in the hospital pathology laboratories. Electroanalytical sensing platforms have the potential to meet these requirements. This review aims firstly to reflect on the potential benefits of rapid CB testing in critically ill patients, a very distinct cohort of patients with deranged baseline levels of CBs. We summarise their source and clinical relevance and are the first to report the required analytical ranges for such technology to be of value in this patient cohort. Secondly, we review the current electrochemical approaches, including its sub-variants such as photoelectrochemical and electrochemiluminescence, for the determination of important CBs highlighting the various strategies used, namely the use of micro- and nanomaterials, to maximise the sensitivities and selectivities of such approaches. Finally, we consider the challenges that must be overcome to allow for the commercialisation of this technology and transition into intensive care medicine. GRAPHICAL ABSTRACT: [Image: see text] Cardiovascular dysfunction is a frequent complication of critical illness. Approximately 30% of patients admitted to the intensive care unit (ICU) have underlying cardiac diseases, and approximately 50% of this group are admitted to the ICU with cardiac problems as the primary cause [1, 2] . This includes conditions such as acute myocardial infarction (AMI), heart failure (HF) and cardiogenic shock. However, cardiac complications can arise in ICU patients who have been admitted due to other critical illnesses such as sepsis [3] , severe burns [4] and brain trauma [5] . ICU patients are exposed to high levels of non-cardiac stress, which in turn, increases myocardial oxygen consumption. In some patients, the myocardial oxygen supply may be reduced by hypotension, tachycardia, hypoxemia and anaemia. The heart is one of the most frequent organs to fail in critically ill patients [6, 7] , and this can have several profound implications for a patient's prognosis [8, 9] . As such, accurate assessment and monitoring of cardiac function in the ICU is vital to patient care. Identifying cardiac dysfunction in critically ill patients, however, can be difficult. Co-morbidities and other confounding factors, along with the non-specificity of clinical symptoms, complicate diagnosis. Furthermore, the broad aetiologies behind cardiac dysfunction, are echoed by a wide range of cardiac pathophysiologies, and yet, prompt, appropriate stratification and treatment is crucial to patient outcome, since the acute nature of the dysfunction in many cases, can result in rapid patient deterioration and ultimately, death. Repeated monitoring of cardiac function over time is also vital and comprises assessment of the initial haemodynamic state, and ongoing evaluation of any change in this state that can indicate patient deterioration. Furthermore, assessment of the heart in response to administrated therapies is important in critically ill patients. Ideally, testing for cardiac dysfunction on the ICU should be performed using techniques that are rapid and can be performed repeatedly, with ease. Cardiac biomarkers (CBs) are produced as a result of a pathological processes in the cardiovascular system. Several are now well-established and routinely used to aid diagnosis of a cardiac event, particularly within the emergency medicine setting, and to identify the progression of cardiovascular diseases [10] [11] [12] [13] [14] [15] . Indeed, biomarkers of cardiac injury have been used to aid the diagnosis of AMI for over half a century, with aspartate transaminase (AST) being the first CB to be used in clinical practice [16] . However, the lack of specificity of AST for myocardial injury quickly saw it superseded by more clinically relevant CBs which could be used to identify AMI in an emergency room setting, and technologies for their rapid and accurate detection have been sought. Although testing for certain CBs in emergency and cardiology settings is relatively commonplace, CB testing on the ICU is performed far less frequently. However, CB testing in critical illness has gained significant interest, with the hopes of providing useful information to supplement that provided by more conventional cardiac assessment methods. Indeed, diagnoses and patient stratification based on more traditional methods such as echocardiography are not always sufficient to inform the most appropriate treatment or management strategy. For example, while an enlarged right ventricle signifies pressure or volume overloading, imaging cannot aid in determining the aetiology. Similarly, ECG has been reported to have a low sensitivity for identification of AMI in the critically ill population. CBs, on the other hand aid the diagnostic process by providing information on the nature of the cardiac damage, for example suggesting myocardial stretch, inflammation or cardiomyocyte necrosis. CBs are also important for prognostication and risk stratification in critically ill patients, with specific CBs measured early in the patient's ICU stay repeatedly being shown to predict outcome in specific ICU subgroups. Indeed, Cardiac Troponin I (cTnI) strongly predicts mortality and/or length of hospital stay such as in the case of trauma [17] , sepsis [18] , pneumonia [19] and COVID-19, [20] although, cTnI should be considered more as a specific marker / "gold standard" for the diagnosis of AMI [21] . Likewise, other CBs such as Cardiac Troponin T (cTnT) [22, 23] , B-type natriuretic peptide (BNP) [24] , N-terminal (NT)-pro hormone BNP (NT-proBNP) [25, 26] , soluble suppression of tumourigenicity 2 (sST2) [27, 28] and Heart-type Fatty Acid-Binding Protein (H-FABP) [29] , have all been shown to demonstrate some degree of prognostic value in critically ill subgroups. This could be extremely useful for daily practice on the ICU since early measurement of specific CBs may help clinicians to identify early risk of deterioration and may allow for optimisation of ICU resources. Rapid, cost-effective identification of CBs on the ICU therefore holds great potential, since CB testing in this setting is under-utilised. Although point-ofcare (PoC) systems for rapid analysis of Troponins and some natriuretic peptides have been adopted in some settings for ruling-out AMI in patients presenting with acute chest pain, some of these technologies are costly, and all other CBs must be analysed by clinical chemistry analysers or plate-based immunoassay in the hospital pathology department. When considering the development of technology for the rapid detection of CBs, it is vital that the most appropriate CBs are targeted, and this is particularly relevant when considering ICU patient groups; there are a vast number of CBs encompassing enzymes, hormones, and proteins, each with their own set of key attributes and supporting literature; see Table 1 . Some of these are more applicable for patient diagnosis, while others hold greater prognostic significance. It is also extremely important to consider that CBs are generally elevated in the critically ill patient population overall (see Table 1 ) and so require the derivation of separate reference ranges for this distinct cohort. Technologies adopted in the ICU will therefore need to cover a much broader analytical range, than those used to assess CBs in the emergency department for rule out of AMI/HF. Table 1 summarises the evidence for the clinical utility of CBs in ICU patients and provides an indication of the concentrations of each reported in this patient group; from this critically useful table, we overview the electroanalytical approaches to their determination, providing an up-to-date overview. Let us first consider the non-electroanalytical methods for the detection of cardiac biomarkers. Currently there are commercially available analysers for cTn, for example the Table 1 Cardiac biomarkers, their source, clinical relevance, and analytical ranges • Although cTnT and cTnI have very high sensitivity for AMI in the ED [10] [11] , and are included in NICE guidance for early rule out of NSTEMI [30] , in ICU patients the incidence of raised cTnT and cTnI is high (45%), and 70% of these patients do not have flow limiting coronary artery disease • cTnI strongly predicts mortality and/or length of hospital stay in trauma [17] , sepsis [18] , pneumonia [19] and also COVID-19 patients [31] , and can strengthen existing prognostication systems such as APACHE II [32] • The presence of cTn in the blood of critically ill patients may identify sub-cohorts who can benefit from different treatment approaches [33] • Not seen until 6-8 h post myocardial injury, with concentrations peaking at around 12-24 h [34] • Levels can remain elevated for 7-10 days post original myocardial insult, and so this late clearance makes it difficult to identify a recurrent cardiac event [34] • Normal values reported as 99th centile: 14 ngL −1 [35] • Studies assessing the prognostic value of cTnT in ICU patients have frequently used > 10ngL −1 as the cut-off [36] cTnI Cardiomyocytes • Normal values reported as 99th centile: 34 ngL −1 in men, 16 ngL −1 in women [35] • Studies assessing the prognostic value of cTnI in ICU patients have frequently used > 100ngL −1 as the cut-off [36] H-FABP Cardiomyocytes, skeletal muscle, brain and kidney • Previously shown to be effective for diagnosis of ACS and AMI [11, 37, 38] • Proven utility for prediction of PE in ICU patients [39, 40] • Demonstrates prognostic significance in ED patients [29] and also sepsis patients on the ICU [41] • Elevated in critically ill patients, but can predict the development of adverse cardiac events in trauma patients when measured upon admission to the ICU [42] • Present in circulation much earlier following cardiac injury when compared with Troponins [43] , being evident at just 30 min post-injury and peaking at 6-8 h • Rapid clearance, with H-FABP levels returning to baseline approximately 24 h post-cardiac event [44] • However, recent large studies have shown that H-FABP does not improve hs-troponin diagnostic accuracy and that its incremental value over hs-troponin has uncertain clinical significance [45, 46] • Typically, the normal range is considered as: < 5 ng mL −1 . However, at least two different thresholds have been defined as the 99 th percentile of a healthy population, and several cut-off values for H-FABP positivity have been used [47] • The lower the positivity threshold, the better the H-FABP performance, thus, optimal sensitivity has been mostly reported at a cut-off of 4 ng mL −1 [47] . • It has recently been shown that H-FABP is significantly higher in sepsis patients (median 26.6 (range 9.3 to 79.0) ng mL −1 ) than in those with compensated HF (median 6.6 (range 4.6 to 9.7) ng/ ml), highlighting the wide analytic range required for critically ill patients [48] CK-MB Cardiomyocytes, skeletal muscle, brain and kidney • Introduced in 1965 as a biochemical marker for myocardial damage-one of the oldest markers in this field [49] . • Although it has high specificity for diagnosis of AMI, it has low specificity, and hence is not used in isolation • Repeatedly been shown to demonstrate strong prognostic significance in COVID-19 patients [50] • Released within 12 h after symptom onset of AMI, peaks in serum at 24-36 h, and returns to normal in 48-72 h not suitable for early diagnostics in the setting of acute chest pain • CK-MB may appear raised in other conditions such as rhabdomyloysis or stroke. For this reason, CK-MB is measured in conjunction with Total CK and other cardiac markers such as Troponin T and/ or Myoglobin to produce a clearer clinical picture • Normal range: Male: 0-5.0 ng mL −1 , Female: 0-2.9 ng mL −1 [51] . • Concentrations of > 60 ng mL −1 have been reported in ICU patients, particularly those with hypovolaemic shock Myoglobin • Myoglobin kinetics (detecting a change of 40 ng/ml) within the first hour of acute chest pain is reported to have a 91% sensitivity and up to a 99% negative-predictive value for AMI [52] • It should be noted that myoglobin testing has largely been discontinued in clinical laboratories since cTnT or cTnI assays have increased in sensitivity and is generally viewed as an outdated diagnostic marker • Myoglobin has been shown to possess prognostic value in sepsis [53] and COVID-19 patients, and may be superior to cTn in that respect [54, 55] • Elevated levels are normally detectable between 2 and 6 h after MI peaking within 5-18 h. It is generally detectable before CK-MB and cTn [56] • Normal range: 25-90 ng mL −1 [56] • Ideally, an assay for myoglobin should have a sensitivity of < 5 ng mL −1 and a dynamic range of at least 500 ng mL −1 [56] Neuroendocrine markers and indicators of myocardial stretch • Signifies ventricular myocardial stretch and is hence useful in diagnosis of HF • Increased BNP level is a strong predictor for cardiac dysfunction in ICU patients [2] • Can aid in the diagnosis of cardiac dysfunction in ICU patients, but cannot replace echocardiography-merely indicates the presence of a 'cardiorenal distress' and should prompt further investigation [57] • Also shown to be useful for prognostication in sepsis and COVID-19 [24, 58] • In response to myocardial wall stretch, pre-proBNP is synthesised and processed to proBNP; which is further processed to the biologically inactive NT-proBNP fragment and the biologically active BNP fragment • Circulating BNP levels are similar to NT-proBNP in normal individuals but are significantly less elevated by left ventricular dysfunction than NT-proBNP [59] . • Mean (SD) BNP in healthy controls is reported as 56.87 ng/L (22.76ngL −1 ) [24] • BNP < 100 ngL −1 , CHF unlikely [59] . • BNP 100-500 ngL −1 -equivocal range [59] . • BNP > 500 ngL −1 consistent with the diagnosis of CHF [59] . • Values of ≈500ngL −1 reported in critically ill patients without diagnosis of cardiac complication [24, 58] NT-proBNP [73] [74] [75] , and can rapidly identify left ventricular systolic dysfunction in sepsis patients [76] • MR-proANP is superior to BNP and pro-BNP in predicting death in CF patients [77] • It has shown strong prognostic utility in AIS, independently predicting post-stroke mortality and functional outcome [78] • It has shown diagnostic value for AHF in patients with acute dyspnoea [67] • In response to increased tension of the atrial wall, the active hormone ANP is secreted by splitting of its precursor into NT-proANP, and an active hormone ANP Copeptin • Useful in combination with cTn to safely and effectively ruleout AMI on admission with the first blood sample [80] • However, since the introduction of hs-cTn, copeptin has been shown to provide very little additive value [81] • Circulating levels of copeptin at ICU admission independently predict mortality in critically ill patients [82, 83] • Copeptin levels correlate with markers of renal failure and metabolic disturbances in ICU patients [84] and correlate with severity of sepsis [85] and traumatic brain injury [86] • Copeptin assays are of extremely limited application diagnostically or prognostically for cardiac dysfunction [87] [85] Inflammatory markers IL-6 • Increased levels of IL-6 are associated with deteriorating functional class of HF and with worse outcomes and adverse cardiac remodelling in these patients [88, 89] • IL-6 has been proposed as a potential therapeutic target in HF [90] • IL-6 concentration, independent of the already established predictors, correlates with adverse cardiac events [77, 78] • IL-6 concentrations are an independent predictor of 30-day mortality in patients with AMI complicated by cardiogenic shock [91] • IL-6 is a well-established independent prognostic marker in patients with COVID-19 and sepsis [92] • There is huge interest in introducing routine measurement of IL-6 into critical care, particularly since the IL-6 receptor became a therapeutic target in COVID-19 • IL-6 is elevated in a wide range of inflammatory conditions, stimulated via Widely expressed by numerous cell types, but in the heart, it is mainly located in vascular endothelial cells and cardiac resident mast cells • This marker is certainly not cardiac specific and is elevated in a wide range of inflammatory conditions, particularly so in critically ill patients [102] • Elevated TNFα levels can produce LV dysfunction, cardiomyopathy, and heart failure; raised serum TNFα is seen in patients with these conditions [88, 103] • In patients with advanced heart failure, TNFα concentration is an independent predictor of mortality [88, 104] tion, therefore useful from a diagnostic perspective [106] • sST2 measurement on ICU admission has been shown to be useful to identify patients with higher risk of developing adverse cardiac events during unit stay [106] • Multiple studies have shown sST2 to be an excellent discriminator of mortality in patients with HF and AMI, and also non-cardiac ICU patients [107, 108] . sST2 has also shown prognostic and diagnostic value in ARDS [109] • The prognostic value of sST2 is additive to natriuretic peptides and (in the case of chronic HF) to cTnT • Released in response to ventricular stretching, vascular congestion and inflammatory and profibrotic stimuli • Currently, measurement of sST2 has not been approved in the clinical guidelines as a prognostic biomarker of adverse outcomes in AMI. However, in the guideline of HF, sST2 is recommended for additive risk stratification, especially in the acute phase • It has been suggested that current data on sST2 justifies its measurement at least on admission for acute HF, and at the planned discharge to identify those patients with sustained elevated levels. This may predict; 1) a prolongation of hospital stay 2) those who may require a more rapid up-titration of HF drugs (after hemodynamic stabilization) 3) requirement for the use of monitoring systems to detect pulmonary congestion [110] • in some ICU patients [108] . Gal-3 Macrophages, neutrophils, endothelial cells, epithelial cells • Used for risk stratification /prognosis rather than diagnostics, especially in HF with preserved ejection fraction • Shown to predict mortality and HF hospitalisation and to correlate positively with LV end-systolic and end-diastolic volumes [112, 113] • Associated with mortality and increased risk of incident HF [114] . • A predictor of mortality, ICU access and ARDS stratification in patients with COVID 19 acute respiratory failure [115] • Directly induces pathologic remodelling of the heart-implicated in the development of cardiac fibrosis • Normal range: 3.8-21.0 ng mL −1 (from Gal-3 analysis in 1092 healthy volunteers aged ≥ 55 years from the Biolmage cardiovascular risk study) [116] • Values in HF have been reported between 5.0 and 66.6 ng mL −1 (from Gal-3 analysis in 592 HF patients) [117] • Values of ≈ 80 ng mL −1 have been reported in critically ill patients [27] GDF-8 (Myostatin) Primarily, skeletal muscle, but also cardiomyocytes • Used for risk stratification /prognosis rather than diagnostics • Upregulated in the heart after volume overload • GDF8 correlates strongly with other biomarkers related to HF severity [118] • Shown to reflect the extent of myocardial damage during AMI, similar to peak cTnI [119] . • Shown to reflect the severity of CHF and predict adverse prognosis in CHF patients [120] . • Conversely, low myostatin levels are associated with lower survival rates on the ICU, and baseline myostatin serum levels are an independent prognostic marker for overall survival in critically ill patients [121] . Levels are further significantly reduced in ICU patients requiring mechanical ventilation compared with those not [121] GDF-8 is a negative regulator of skeletal muscle mass. It is significantly upregulated in muscle wasting conditions independently of cardiac dysfunction. However is also considered to be instrumental in the skeletal muscle wasting phenomenon in heart failure, cardiac cachexia and general critical illness [122] • Multiple cell types, including cardiomyocytes, adipocytes, macrophages, endothelial cells, and vascular smooth muscle cells • Used for risk stratification /prognosis rather than in diagnostics • Can predict risk of CV death/HF [123] , recurrent MI [124] , as well as risk of bleeding in NSTE-ACS patients [124] • GDF-15 is raised in ICU patients in general compared with controls [125] , but is raised further in sepsis [125] , ARDS [126] , PE [127] and CS [128] • Prognostic value has been shown to be independent of traditional risk factors such as previous MI, age, elevated levels of other cardiac biomarkers • GDF-15 correlates with manifestation of organ failure including renal and hepatic failure and is associated with disease severity (APACHE II and SOFA) [125] • A stress responsive member of the transforming growth factor β superfamily TnI-Ultra assay (ADVIA Centaur XP immunoanalyzer, Siemens Healthcare Diagnostics) and the cTnT assay (Elecsys TnT-hs, Roche Diagnostics). The cTnI assay can achieve detection in plasma as low as 0.006 ng mL −1 and spanning a range of 0.006-50 ng mL −1 , whereas, the cTnT assay has a limit of detection (LOD) of 0.005 ng mL −1 and can detect its presence up to 50 ng mL −1 . These lab-based methodologies have improved significantly, with the Roche Troponin T assay able to produce results in a single hour [132] . However, there is still a huge drive for portable, reliable, and low-cost devices. Several commercial PoC benchtop devices are also available including BioMerieux Vidas, Mitsubishi Pathfast, and Radiometer AQT90, but development of more portable, hand-held, low-cost devices is still warranted. Due to the significance of the topic, a plethora of other sensing methodologies have been reported throughout the literature for the detection of CBs. As such there are numerous reviews tackling many topics and their application to the detection of CBs which we direct the reader towards. These include general CB biosensors [133] [134] [135] [136] , lab-ona-chip devices [137] , fluorescence [138] , colourimetric [139] nanomaterial-based [140, 141] , acoustic-wave [142] , potentiometric [143] , and optical [144] to name just a few. Additionally, there have been reviews for electrochemical strategies [145] [146] [147] , which often highlight a small number of markers or cover multiple detection methods. Herein, we focus solely on electrochemical-based strategies, giving comprehensive coverage of the published literature for the detection of a wide range of clinically proven and emerging CBs. Now let us consider that the electrochemical detection of cardiac biomarkers is an area of huge interest, with a plethora of different and interesting approaches reported. As expected within the exciting field of biosensor development, there are numerous works that utilise very similar strategies to achieve their end-goal of the quantification of the target biomarkers. For example, the use of EDC (carbodiimide compounds)/ NHS (N-hydroxysuccinimide) coupling to covalently attach a bio-recognition element (e.g. protein/peptide) to the electrode surface, the utilisation of Au-S bonding on gold electrodes or the electrodeposition of AuNPs are widely utilised. It is commonplace for almost identical systems to be reported, varying only the electrochemical method (cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS) etc.), photoelectrochemical (PEC), electrochemiluminescence (ECL), nanomaterial used (metallic nanoparticles, graphene, carbon nanotubes etc.) or simply the target detected. As such, we have aimed to include a comprehensive survey of the literature for each biomarker discussed in the form of tables for each section, highlighting the electrodes used alongside any modifications, the recognition element used, target biomarker and electrochemical detection technique used along with the key analytical parameters and real sample matrix. We do this whilst highlighting some unique and novel advances in biosensor technology and in cases where the literature is too vast (for example cTnI, cTnT and myoglobin) we will focus predominantly on strategies presented in the last 5 years. The electrochemical biosensors utilise three key recognition elements; these are antibody, aptamer, or molecular imprinted polymers (MIPs) person-made mimics of antibodies. Antibodies are widely used in the pharmaceutical industry but can be expensive, have limited stability and require the use of animals. A new approach is to utilise aptamers, synthetic molecules that can be raised against any kind of target and can bind their target with an affinity similar to, or higher than antibodies. Aptamers are ~ tenfold smaller than antibodies and can be chemically modified atwill in a defined and precise way. They can be easily stored and delivered, an advantage over antibodies, can be reversibly heat-denatured, and have a high batch to batch reproducibility. More recently, MIPs have been developed. These are artificial, highly cross-linked polymeric receptors that are engineered towards the binding of specific target analytes. This binding interaction is facilitated by nanocavities that are disturbed throughout the synthesized polymeric network, reflecting the conformation and chemical functionalities of the imprinted molecule or species. Advantages over conventional antibodies include superior chemical and thermal stability, ability to tailor the MIP to the template, and low-cost [148] . Clearly, all three recognition elements can be used in the development of electrochemical biosensors, but the advantages of aptamers and MIPs over antibodies is clear. Despite this, their advantages are not being fully utilised. The literature for this marker, alongside cTnI, is vast and we concentrate on the last 5 years only, which are summarised in Table 2 . It is clear that immunoassay, aptamer and MIP based technologies are all being explored towards cTnT detection, producing clinically relevant linear ranges and detection limits with validation in predominantly human serum. Radha Shanmugam et al. [149] reported a multi-sensor immunoassay for cTnT and cTnI based on gold electrochemical platforms decorated with zinc oxide nanorods. Figure 1A shows a schematic overview of the sensing platform. In this approach, the multi-sensor is based upon thin film fabrication technology with a few nm ZnO seed layer deposited onto the working electrode via RF-Magnetron sputtering after which acts as nucleation sites for further hexagonal shaped ZnO nanorod growth when subjected to a low temperature hydrothermal bath consisting of a zinc nitrite salt and hexamethylenetetramine dissolved in water. The resultant morphology is the vertically oriented ZnO nanostructures, with their ends functionalised with an amine reactive crosslinker molecule-(dithiobis(succinimidyl propionate)), where the NHS ester group at its terminal end provides an amino-reactive surface that forms amine linkage with primary amine groups in the antibody molecule. The authors utilised electrochemical impedance spectroscopy (EIS) and Mott-Schottky analysis on the same sensor platform to demonstrate multi-configurable modes which allowed, via a "signal off" mechanism, the simultaneous measurement of cTnT and cTnI over the range of 0.1 to 1 × 10 5 pg mL −1 with a LOD in human serum reported to correspond to 1 pg mL −1 for both cTnI and CTnT [149] . The authors report that ZnO is an attractive nanostructured material due to a high isoelectric point and high catalytic efficiency with the ability to align vertically the ZnO to provide a large surface area and useful attachment sites for the antibodies. The authors extended this to measure simultaneously cTnI, cTnT and BNP, showing the successful determination in human serum over the range of 1 pg mL −1 -100 ng mL −1 with a LOD of 1 pg mL 1 [150] . Jiang and co-workers [151] have developed an immunoassay sensor utilising electrochemiluminescence (ECL) via the fabrication of silver nanoparticles functionalized SnO 2 nanoflowers where the latter are in the range of 1-2 µm fabricated via a facile hydrothermal methodology. The SnO 2 nanoflowers were then functionalised with 3-aminopropyltrimethoxysilane (ATPES) by adding this dropwise into a solution containing the nanoflowers. These aminated nanoflowers were then dispersed into a glutaraldehyde solution to obtain aldehyde-terminated SnO 2 nanoflowers. The nanoflowers were next dispersed into an ethanol solution to form a suspension with a silver ammonia solution added to obtain silver nanoparticle modified SnO 2 nanoflowers via the traditional silver mirror reaction. To functionalise the Ag@SnO 2 nanoflowers with the cTnT antibody probe, the former were simply mixed with the latter with an incubation of 12 h. Subsequently, bovine serum albumin (BSA) was added to the same solution to block the unspecificed nonspecific binding sites. The basis of the sensor is a sandwich type immunoassay with the second antibody attached to gold nanoparticles all supported upon a GCE. In the presence of cTnT, the sensor is a "signal on" where the ECL intensity is greater when the cTnT has binded between the two antibodies. The sensing approach requires 10 mM S 2 O 8 2− in the solution that is measuring the target cTnT. The authors believe that the silver nanoparticles serve as a co-reaction accelerator which is able to react with the co-reactant of S 2 O 8 2− for facilitating the ECL reaction between the SnO 2 8 2− (no silver nanoparticles). The immunoassay exhibited a large linear range from 1 fg mL −1 to 100 pg mL −1 with a LOD of 0.11 fg mL −1 reported. The immunoassay was shown to successfully determine cTnT in spiked human serum with recoveries in the range of 91.36 to 112.7%. Recently, Pourali and co-workers [152] reported a biosensing platform based on a sandwich immunoassay utilising CdS quantum dots (QDs). They developed a onepot synthesis method for producing monodispersed CdS semiconducting nanocrystals (5 nm diameter), through the facile mixing of pre-cursers into a solvent system of dibenzyl ether and oleylamine. These nanocrystals were further modified with streptavidin and used for the signal enhancement. Detection was achieved through the binding of the CdSstreptavidin to biotinylated secondary antibodies followed by the use of square-wave anodic stripping voltammetry. Using this methodology, where the sensing mechanism is a "signal on", the authors obtained a dynamic linear range from 5 to 1000 ng L −1 (0.005-1 ng L −1 ) with a detection limit of 2 ng L −1 . The authors tested the effect of avidin, myoglobin and CK-MB, showing that the sensor retained at least 92% of its response. They further validated their results in human serum achieving RSD values of 9.8, 7.5 and 3.6% for three different fabricated immunosensors, additionally measuring recovery values between 95.6 and 105.1%. Silva and co-workers developed a nano-molecularly imprinted polymer (N-MIP) assembled on reduced graphene oxide modified screen-printed graphite electrodes for sensing cTnT [164] . The biomimetic surface was obtained by first taking screen-printed graphite electrodes, which are then surface modified (via drop casting) with reduced graphene oxide; the authors attribute the use of reduced graphene oxide to improve electron transfer rates. The N-MIP was fabricated by taking the reduced graphene oxide screenprinted electrode and placing it into a solution containing cTnT, pyrrole and carboxylated pyrrole (COOH-3-Py) which is then electropolymerized via cyclic voltammetry. The authors explored a range of monomers in order to reach a maximal electron transfer; they also used organic polymers containing functional groups (carboxyl) in order to obtain more reactive biomimetic sites of the cTnT. The authors found that pyrrole and carboxylated pyrrole (COOH-3-Py) provided the best biomimetic conductive polymer where the carboxylic group in position 3 at the monomeric ring linked to the carboxylic group allowed the promotion of more interactions between reactive sites with cTnT. The authors justified their use of reduced graphene oxide in order to increase the synergy with PPy to increase electron transfer rates and promote greater numbers of biomimetic sites due to the nanostructured electrode surface area [164] . A critical parameter for N-MIPs is determining the dissociation constant, K D which can be calculated using a Langmuir isotherm model: where I CD is the current density, S is Fig. 1 A) Schematic representation of sensing cTnI and cTnT biomarkers in a multiplexed sensor array format, utilising antibodies attached to ZnO nanorods. Reproduced with permission from ref [149] . Copyright Elsevier 2017. B) (i) Preparation process of the Ab 2 / Ag@SnO 2 NFs signal probe; (ii) construction of the self-accelerated Ag@SnO 2 NFs-based ECL immunosensor and (iii) proposed ECL mechanism for this system. Reproduced and adapted with permission from ref [151] . Copyright Elsevier 2018 the concentration of the target (cTnT), and I max is the maximum current density. In terms of the N-MIP towards cTnT, a K D of 7.3 x 10 −13 mol L −1 was found compared to the control (N-NIP) of 11.6 x 10 −13 mol L −1 reflecting a high affinity of the biomimetic sites to low cTnT concentrations. The authors noted that the K D value of the N-MIP is comparable to that of conventional antibodies that exhibits K D in the range of 10 −7 -10 −9 mol L −1 [164] justifying their experimental development. The N-MIP modified electrodes were found to detect cTnT over the range 0.01 to 0.1 ng mL −1 with a very low LOD (0.006 ng mL −1 ) found to be possible using DPV. The authors went further and examined the N-MIP modified electrodes in human serum comparing their response with gold-standard ECLIA assays with recoveries found over the range of 97-115%. Phonklam et al. [166] followed a similar approach for the sensing of cTnT using MIPs upon screen-printed carbon electrodes with multiwalled carbon nanotubes modified via electrodeposition with the redox probe polymethylene blue. The authors reported that the use of carbon nanotubes increased the electrode area with a three-fold increase in the peak current/signal compared to the case of a bare electrode surface. The MIP was formed via the electropolymerization of polyaniline with the sensing mechanism based upon the redox probe polymethylene blue, where the binding of the cTnT with the MIPs impedes the electron transfer of the oxidation current providing a "signal off" sensor. The sensor was found to detect cTnT over the range of 0.10-8.0 pg mL −1 with a LOD of 0.040 pg mL −1 using DPV. The MIP sensor exhibited an excellent binding affinity (K D = 2.8 × 10 -13 mol L −1 ) comparable to others formed via different fabrication strategies and found that the sensor retained more than 90% of the sensitivity after 6 weeks of storage at room temperature. The authors determined cTnT in spiked human plasma which was found to compare well with an independent electrochemiluminescence method. MIPs clearly are an active range for sensing cTnT and from inspection of Table 2 we can see a range of MIPs [164] [165] [166] [167] [168] all evaluated in real samples and providing linearly useful analytical ranges. When considering application of such technologies in the ICU setting, we must be mindful of the analytical ranges needed, since these are typically developed with AMI "rule-out" in the emergency setting in mind; typical concentrations of cTnI in ICU patients may be in the region of 1000-1500 ng L −1 with many technologies being capable of translation into this setting [36] . From inspection of Table 2 , a range of approaches have been reported utilising nanomaterials, such as using acetic acid functionalized graphene quantum dots (fGQDs) for an antibody free approach with a reported linear range of 0.17-3 ng mL −1 and a LOD of 0.02 ng mL −1 [169] . While the mechanism is attributed to hydrogen bonding interactions mediated by the carboxylic group in the fGQDs, the sensor is of limited use, if any, due to the lack of tests on real samples. As can be seen in Table 2 , a large majority evaluate their sensor in real samples (human serum) which is a must for the credibility of any sensor. Ma and co-workers have reported an electrochemical immunoassay for the sensitive monitoring of cTnI using a novel controlled release systembased antigen-response [171] . Figure 1B shows a schematic overview of the electrochemical based immunosensor which is based upon Fe 3 O 4 -NH 2 nanospheres (mean diameter of 150 nm) produced via a one-step solvothermal methodology. The nanospheres are mixed with glutaraldehyde (GLH) to provide functionalisation sites and the cTnI antibody and incubated for 2 h. Following this, bovine serum albumin (BSA) is used to block remaining active sites. Next, the surface is modified with the cTnI antibody and cobalt phthalocyanine nanoparticles (8-10 nm diameter). Aminated polystyrene microspheres (APSM) are then used to cover the mesoporous negative charged Fe 3 O 4 -Ab by electrostatic adsorption. As cTnI is introduced/analysed, APSM is separated from the Fe 3 O 4 nanospheres which also releases the cobalt phthalocyanine nanoparticles. These latter released nanoparticles catalyse the added hydrogen peroxide (see Fig. 1B ) and provide the electroanalytical signal via a "signal on" approach. This immunoassay was able to measure cTnI from 1.0 pg mL −1 to 100 ng mL −1 with a LOD of 0.39 pg mL −1 using amperometry. The authors went further and demonstrated their biosensor to measure cTnI in human serum with good recoveries (96.7-98.9%) and validated the proposed bioanalytical approach with ELISA indicating the biosensor to have a high accuracy and potential for clinical uptake. Mi et al. [196] have reported a ratiometric aptamer based sensing approach based upon the ECL signal of doxorubicin (Dox)-luminol or the electrochemical (EC) signal of methylene blue (MB) vs. referable EC signal of Dox. Figure 2 shows a schematic overview of the ratiometric aptamer sensor which utilises Ti 3 C 2 -MXene nanosheets fabricated by ultrasonic exfoliation resulting in 2 nm thick sheets indicating that they are few or single layer. The MXene nanosheets are then modified with gold nanoparticles and tetrahedral DNA (capture probe) which is combined with Au@Fe 3 O 4 nanoparticles modified with Tro4-aptamer. In this approach, when cTnI binds with the aptamer, BFP (DNA sequence) is released, which hybridizes with the capture probe. A ECL luminophore (Dox-luminol complex) prepared by the crosslinking between Dox and luminol is used to amplify the ECL signal. Alternatively, the electrochemical signal of methylene blue can be used as an indicator allowing the sensor to be used as ECL Dox-luminol /Current Dox or Current MB /Current Dox (see Fig. 2 ). The approach provides a highly useful calibration signal (stable current signal, see Fig. 2 ) which increases the accuracy of detection which occurs via a "signal on" approach. The sensor is shown to be able to measure cTnI over the range 0.1 fM to 1 pM (0.00239-23.9 pg mL −1 ) with a LOD of 0.04 fM (0.97 fg mL −1 ). The authors demonstrated the sensor to measure cTnI in human serum and validated the measurements with ELISA which provided excellent agreement suggesting the sensor could be routinely used for the clinical measurement of cTnI. Of note, Yang and co-workers [163] have utilised ECL for the simultaneous measurement of cTnT, cTnI and Myoglobin. Figure 3 shows the aptamer-based system and how the sensor is fabricated. The biosensor is based upon a gold macroelectrode array (2 mm diameter) which is modified with the cTnT, cTnI and Myo ssDNA aptamers and then with cysteamine (CysA). The sensor is then exposed to the analyte targets (cTnT, cTnI and Myoglobin) for 60 min which is then modified with a solution of biotinylaed antibody and the ECL probe, a ruthenium complex-labelled streptavidin (Ru1-SA). The ECL signal is based upon Ru(bpy) 3 2+ -tripropylamine (TPA) undergoing electron transfer at the electrode surface to form an excited, light emitting state; see Fig. 3 . Through the use of an Electron Multiplying Charge Coupled Device (EM-CCD), the ECL intensity-potential profiles are obtained providing the analytical signal. The multi-sensor was able to measure cTnT, cTnI and Myoglobin over the following linear ranges: 0.50-4.0 ng mL −1 , 0.0010-0.010 ng mL −1 , 0.050-1.0 ng mL −1 respectively with low detection limits of 0.30 ng mL −1 , 0.79 pg mL −1 and 31 pg mL −1 respectively. Despite the achievement of excellent sensitivities, the dynamic ranges would need to be extended to be of use clinically, since the 99 th centile for cTnI for both men and women is outside of this range and given that concentrations of cTnI in critically ill populations can reach tenfold higher than the upper LOD reported here. The potential applicability of the sensor was shown to be viable in human serum samples with a commercial immunoassay. Again, it is important to consider the concentrations that may be seen in ICU patients to assess whether such technologies could be translated into this setting; it is recommended that a Myoglobin assay have a dynamic range of at least 500 ng mL −1 [56] and so some modifications would need to be made to achieve this. We would remind the reader, that although Myoglobin is generally considered an outdated CB for investigation of AMI/HF in emergency settings, very recent studies have shown its usefulness in sepsis and COVID-19 and have suggested it is superior to troponins in these settings [52] [53] [54] . Singal and co-workers [174] reported a simple yet elegant approach using a 3-dimensional graphene-multi walled carbon nanotube (G-MWCNT) hybrid prepared using a one-step chemical vapor deposition method with acetylene as a precursor source. The G-MWCNT film was transferred onto a glassy carbon electrode and modified with the cTnI antibody, attached through a molecular bi-linker, 1-pyrene butyric acid N-hydroxysuccinimide ester (PyBuNHS). The sensor exhibited a linear range from 1.0 pg mL −1 to 10 ng mL −1 with a LOD of 0.94 pg mL −1 using EIS and was shown to be successful to determine cTnI in human serum. Last, of particular note is work by Zhang and co-workers [172] who reported a complex electrode configuration [171] . Copyright Elsevier 2019. B) An illustration of (i) the specific target recognition and BFP release, and (ii) the ratiometric biosensing mechanism for cTnI using an MXENE based sensor. Reproduced and adapted with permission from [196] . Copyright Elsevier 2021 but yet provided the basis of a sensor for the ultrasensitive determination of cTnI with a LOD of 33.3 fg mL −1 and a linear range from 1 × 10 −4 to 100 ng mL −1 . The sensor is a sandwich type sensor based upon the use of nanoparticles labelled with antibodies with the sensing mechanism occurring via a "signal on" approach. A glassy carbon electrode, gold nanoparticle and thionine decorated amino-functionalized microporous carbon spheres provide the sensor platform, while gold nanotubes decorated with palladium, which have an average size of 35 nm diameter, are modified with β-cyclodextrins functionalized with 3D-dimensional porous graphene. Both nanoparticle composites are modified with antibodies. The sensing mechanism is based upon the increased electrocatalytic reduction of H 2 O 2 mediated by thionine, resulting in a sensitive and reliable sensor response. The sensor was shown to successfully measure cTnI in spiked human serum and was compared with ELISA. Recoveries of between 98.0% and 102.4%, RSD values ranging between 3.3% and 4.5% and the relative error (1.7% to 3.8%) between the proposed sensor and ELISA suggest that the fabricated immunosensor has potential for the clinical application for cTnI detection. The first Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) was reported by Ohkaru in 1995 [234] with the first electrochemical-based assay reported in 1996 [235] and many reported over recent years. Table 2 provides a summary of electrochemical based endeavours for the detection of H-FABP using a range of different and diverse nanomaterial sensing based platforms. Feng and co-workers have developed a ratiometric immunosensor for H-FABP; Fig. 4A ,B shows a schematic diagram of the fabrication steps of the sensor and how it measures H-FABP [205] . The sensor utilises gold nanodendrites (Fig. 4C ) synthesised by a simple methodology with ciprofloxacin hydrochloride coupled by attaching them onto chitosan-grafted-ferrocene Figure 4C , D shows a simplified image of the electrochemical sensing platform towards H-FABP and the resulting DPV curves from increasing concentrations of H-FABP. Note that ratiometric immunosensors have two "read outs", i.e. two analytical signals with which to monitor the output of the sensor where the thionine and the ferrocene are both electroactive. This is a common approach to utilise these electrochemical redox probes in immunosensors and can potentially allow for self-calibration with improved sensitivity and accuracy over single-signal approaches. The sensor measures H-FABP over the range 0.001 to 200.0 ng mL −1 and has a very low LOD of 0.53 pg mL −1 . The authors demonstrated the successful determination of H-FABP in human serum with recoveries of 100.1-101.7%, indicating that the sensor holds promise in clinical application [205] . Gan and co-workers [206] reported a highly sensitive electrochemiluminescence sandwich immunosensor for H-FABP determination based on a self-enhanced luminophore coupled with ultrathin 2D nickel metal-organic framework nanosheets. The nanosheets were synthesised via a surfactant-assisted methodology with the wrapping of PEI to produce an amino group to cross-link with luminol via glutaraldehyde which was then modified with H-FABP antibodies via gentle stirring overnight followed by adding BSA to eliminate nonspecific binding sites. The underlying ELC immunosensor is based upon a glassy carbon electrode (drop cast) modified with poly(indole-5-carboxylic acid) to increase the surface area with improved conductivity. The modified electrode was then immersed into a solution of NHS/EDC/MES for 12 h to activate the carboxyl group of the poly(indole-5-carboxylic [205] . Copyright Elsevier 2021 acid). After this step, H-FABP antibodies were added by dropped solutions containing the antibody onto the electrode surface followed by the addition of BSA. This ECL immunosensor mechanism is based up on a "signal on" approach and was shown to exhibit a very wide detection range from 100 fg mL −1 to 100 ng mL −1 with an ultra-low LOD of 44.5 fg mL −1 and was shown to measure H-FABP in human serum with recover ranges from 98.7 to 102.7% with low % RSDs (4.2-8.4%). The authors ascribed the highly sensitive nature of the sensor to the following reasons: 1) the Ni-TCPP (Fe) nanosheets exhibiting good catalytic activity toward H 2 O 2 decomposition but also acted as ideal nanocarrier for luminophore immobilization; 2) the use of a luminophore with a high stability, which shortens electron transport distance and reduce energy loss, effectively improving both the quantity and availability of luminol; 3) due to excellent conductivity and large surface area, poly(indole-5-carboxylic acid) (PICA) can facilitate electron transfer and significantly increase the immobilization amount of antibodies for further improvements in sensitivity [206] . The authors did comment that the conductivity of the Ni-TCPP (Fe) nanosheets is relatively low compared with noble metal nanomaterials, such that further improvement could be made through their incorporation in future sensors. Very recently, a MXene (Cd 0.5 Zn 0.5 S/d-Ti 3 C 2 T x ) composite as signal amplificator and core-shell high-crystalline graphitic carbon nitride@ carbon dots as electrochemical sensor platform have been utilised as the basis of an sandwich type immunosensor which operates via a "signal on" approach [207] . The MXene was prepared by subjecting a Ti 3 AlC 2 MAX phase to etching in HCL/LiF for 20 h following ultrasonic treatment and centrifugation, delaminated MXene was obtained (d-Ti 3 C 2 T x ). The d-Ti 3 C 2 T x was added to an aqueous solution containing zinc and cadmium acetate salts, thioacetamide and subjected to a hydrothermal treatment at 180 degrees for 20 h. Following centrifugation, Cd 0.5 Zn 0.5 S/d-Ti 3 C 2 T x is collected. This composite is then modified with H-FABP-antibody via magnetic stirring. The supporting electrochemical sensor platform was fabricated via a lengthy process which starts with carbon dots (CDs) being formed via the reaction of citric acid and ethylenediamine being heated at 250 degrees for 6 h and after cooling, impurities were removed via dialysis for 70 h. The CDs are then combined with a Ni foam template and dicyandiamide with crystallisation performed at 75 degrees for 15 h and then treated in a muffle furnace at 600 degrees for 90 min. The nickel foam is removed via treatment with 10 M acid with finally obtaining high-crystalline graphitic carbon nitride@carbon dots. These are then modified onto a glassy carbon electrode, coupled with the H-FABP antibody via drop casting, followed by the application of BSA. The immunoassay exhibited a linear range from 0.01 to 1.00 pg mL −1 with a LOD of 3.30 fg mL −1 [207] using DPV. While the immunosensor was shown to be highly selective in model solutions against 10 competitive proteins, with a single sensor shown to be able to be used over 50 times, no real samples were considered [207] . Last, as noted above, the detection of H-FABP is limited and generally based upon immunoassays, with very limited reports using MIPs [208] . For example, Sanati et al. [208] reported the development of a MIP based biosensor, based upon ITO modified electrochemically reduced graphene oxide (ERGO). These were modified with highly active surface area core-shelled gold nano/micro-islands (NMIs) via electrodeposition, which allows their size to be tuneable via controlling the electrodeposition process. The MIPs were fabricated via the electropolymerisation of ortho-phenylenediamine using CV in the presence of the target H-FABP. The MIP biosensor mechanism proceeds via a "signal off" and using DPV, exhibited a linear range from 1 fg mL -1 to 100 ng mL -1 towards H-FABP with a LOD of 2.29 fg mL -1 which was attributed to the high surface area of the NMIs and ERGO [208] . The sensor demonstrated two key aspect of MIPs that makes them attractive as the basis of electrochemical sensors, namely, stability and selectivity. In the former, the authors demonstrated the MIP biosensor was stable after 21 days of storage with only an 8.4% decrease in the electrochemical response. In the latter, the authors explored the interference of proteins found in human serum (e.g. albumin, globulin, and fibrinogen) with no effect and also myoglobin (M W = 17.67 kDa) and troponin T (M W = 35 kDa) were found to have no determinantal affect upon the sensor [208] . In summary the electrochemical based sensing strategies to the determination of H-FABP are on first sight, rather limited with all based upon immunoassay technology but have the downside of having multiple components which might be hard to implement in a commercial device. That said, the majority have been shown to successfully determine H-FABP in human serum/blood samples and future work should be used to extend the number of samples measured to produce clinically relevant information for uptake as a commercially device. With the exception of [234] and [203] , the above mentioned sensors already cover the desired analytical ranges needed for assessment of this specific CB in critically ill patients [43] . The use of MIPs is very limited but are simpler in terms of the number of components needed to make a sensor and provide the successful measurement of H-FABP in human serum and plasma samples. Future work should be directed to developing new MIP based sensors. Table 2 summarises various approaches to measuring CK-MB and on further examination, all are entirely focused upon immunoassays with none yet to utilise the potential benefits of aptamers and MIPs. The first electrochemical immunoassay was reported by Yuan and co-workers [236] using a platinum foil macroelectrode, anti-human CK-MB, NADH and ferricyanide, which provides the analytical signal. The authors demonstrated the successful determination of CK-MB in human serum and found a high correlation (0.999) with electrophoresis [236] . Moreira et al. [210] utilised gold screen-printed electrodes which are modified with a phosphorylated form of creatine (Pcrea). Figure 5A shows a schematic overview of the fabrication process where the gold SPE is modified with cysteamine and then via coupling Pcrea with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-Hydroxysuccinimide (NHS). As CK-MB binds to the Pcrea, it is monitored through the electrochemical response via SWV which results in a decrease ("signal off") in the initial electroanalytical signal. The interferents cTnT, BSA, and myoglobin were studied with little effect on the electroanalytical signal and the authors found their sensor was able to measure CK-MB in synthetic urine and serum, [210] but clearly real samples are needed to progress the immunoassay. Li and co-workers [212] extended the work of Moreira et al. [210] using a GCE and demonstrated their immunoassay to work in human serum which compared favourably with an immunohistochemical staining method [212] . Adhikari and colleagues developed an ultra-sensitive label-free electrochemiluminescence (ECL) CK-MB immunosensor using a whole range of nanocomposite-modified single-walled carbon nanotube (SWCNT)-screen-printed electrodes (SPE) [213] . Figure 5B shows the schematic representation of the fabrication steps involved. A SWCNT-SPE is modified with a nanocomposite comprising carbon nano-onions (CNOs) that have been modified with Fe 3 O 4 and gold nanoparticles (AuNP) and then chitosan (CS). All nanomaterials were commercially purchased with fabrication involving simple solution mixing, assembled via electrostatic interactions. The CNOs/Fe 3 O 4 /AuNP/CS composite was then drop casted upon the SWCNT-SPE. Next, the antibody-CK-MB is added onto the surface via drop casting, after leaving to incubate for 12 h, BSA is finally added onto the surface. The authors reported that the highly conductive behaviour of the nanoparticles with an increase in surface area due to the use of Fe 3 O 4 and gold nanoparticles and the carbon nano-onions, may contribute to the enhanced ECL intensity. To monitor the binding of the CK-MB, the electrochemical probe [Ru(bpy) 3 ] 2+ and tri-n-propylamine (TPrA) were selected as the luminophore and co-reactant respectively, with the electrochemical mechanism described by the following: The authors demonstrated that the label free ECL based immunoassay could detect CK-MB over the range 10 ng mL −1 to 50 fg mL −1 with a LOD of 5 fg mL −1 and the authors demonstrated the successful recovery of CK-MB from human serum with the recovery range between 98-103%. The use of screenprinted electrodes as the base electrochemical platform give potential for this to be up-taken commercially due to their lowcost, design flexibility and mass-producibility [237] . Although this sensor would be capable of detecting CK-MB values that fall outside of the normal range of 5 ng mL −1 [51] , further work would be needed to allow concentrations in the range of 60-100 ng mL −1 in critically ill patients to be accurately reported. Other reports have utilised nano-networks [214] such as an AuPdCu alloy fabricated by an eco-friendly one pot synthesis. The nano-networks are fabricated via a one-pot aqueous method where 4-aminopyridine along with gold, palladium and copper salts are mixed together with the reducing agent, ascorbic acid being added last, a process taking 3 h. The product was washed with water and centrifuged and dried in a vacuum. Figure 5C shows a schematic overview of the nano-network immunoassay, where the AuPdCu alloy nano-networks, which are of ~ 3 nm diameter, are drop-cast upon a GCE, which is then in turn modified with anti-CK-MB (via drop casting and 12 h incubation) and then BSA. The underlying mechanism is based upon the addition of hydrogen peroxide into the solution, which is electrochemically reduced at the alloy surface. In the presence of CK-MB which binds to the antibody, the electrochemical surface becomes inaccessible and a decrease ("signal-off") in the electrochemical response is used as the analytical signal; Fig. 5C shows typical chronoamperograms. In using this approach, a linear range of 0.001 to 2000 ng mL -1 was shown to be possible with a LOD of 0.88 pg mL -1 reported and was demonstrated to be successful for the analysis of CK-MB in human serum with good recoveries (98.6-101.2%) with a RSD as low as 3.5%. Furthermore, the sensor could be stored for 28 days at 4 °C with only a 6.4% decrease in the electroanalytical signal. The authors attribute the sensor giving rise to the useful analytical performance to be due to the nano-networks providing a stable and large surface area and excellent biocompatibility for effectively capturing CK-MB [214] . Last, Wang and co-workers [215] have reported a sandwich type immunoassay for CK-MB detection which exhibited a linear range from 0.001 to 2500 ng mL -1 with a LOD reported to be possible 0.62 pg mL -1 using DPV. The sensor fabrication is shown within Fig. 5D where porous PdPt-CoNi@Pt-skin nanopolyhedra particles (67.5-92.5 nm) are fabricated via one-pot aqueous approach and subsequent oxidation etching with nitric acid. These nanoparticles are then modified with thionine by dissolving the PdPtCoNi@ Pt-skin nanopolyhedra particles into water under ultrasonication followed by the addition of thionine (Thi), stirred overnight. The Thi/PdPtCoNi@Pt-skin nanopolyhedra particles were then added into a phosphate buffer solution containing the CK-MB antibody, after which BSA was dropped into the same solution. The composite was obtained via centrifugation and washed. The electrochemical platform was produced by taking a GCE and drop casting gold nano stars, which are fabricated by dispersing thymine into water via ultrasonication until dissolved, accompanied by adding sodium hydroxide to adjust the pH to 11. Immediately after, a gold salt is added with the reducing agent ascorbic acid added dropwise with the reaction complete within 16 h. Onto this surface the CK-MB antibody was drop cast, modified with BSA and ready to use. In this sensor the thionine provides the electroanalytical signal via a "signal on" mechanism with which to indirectly measure the CK-MB. Figure 5D shows a typical DPV signal which demonstrates that the use of a chemical etching, with nitric acid gives rise to more porous PdPtCoNi@Pt-skin nanoparticles. The immunoassay was shown to determine CK-MB in human serum with good recoveries (99.2-101.0%) [215] . Since the replacement of myoglobin with cTn's as the biomarker of choice for the identification of MI, the number of reports on the development of new platforms for its detection have decreased. However, reports will continue to appear in the literature due to the far lower cost of purchasing myoglobin as a commercial analyte, making it the most accessible of the MI markers. The lower cost of myoglobin makes it especially attractive to the development of MIP based sensing platforms due to the large amount of variables needed to optimise (polymer composition, polymerisation methodology, ratios of target to monomer, template removal), in addition to the electrochemical parameters. Ribeiro and co-workers show these steps through the development of a myoglobin MIP based sensor using phenol as the MIP [223] . In this approach the MIP is made via the electrochemical polymerisation of phenol on a gold screen-printed electrode in the presence of Myo as the templating molecule using CV. The authors present the optimisation of the electrochemical parameters, template concentration, imprinting process, template extraction and analytical parameters. They performed their electrochemical oxidation of phenol at a neutral pH in order to facilitate the addition of proteins to the solution, settling on electropolymerisation of 10 mM phenol in the presence of 5 mg mL −1 myoglobin forming a polyphenol MIP with a thickness of ~ 4.4 nm similar to that of the Myo protein diameter. This high quantity of myoglobin required gives an indication of why researchers are hesitant to use a similar methodology with more expensive targets. Using this sensor, the authors achieved a dynamic range of 0.001 ng mL −1 to 100 µg mL −1 , with a LOD of 2.1 pg mL −1 in buffer and 14 pg mL −1 in diluted artificial serum respectively using DPV. Recently, Farahani and coworkers have reported an ultra-sensitive electrochemical sensor for myoglobin based on aptamer recognition and methylene blue loaded co-polymers for signal amplification [228] . They explored the use of two types of poly(styrene)block-poly(acrylic acid) amphiphilic co-polymers, both synthesised through reversible addition-fragmentation chain transfer polymerisation (RAFT), investigating their self-assembly into polymeric vesicles, as well as loading and release efficiency of the electroactive probe methylene blue. It was observed that the PS 61 -b-PAA 596 provided greater loading and release capabilities for methylene blue. The biosensing platform worked through the immobilisation of an aptamer onto a gold surface, followed by incubation with myoglobin and further incubation with a secondary aptamer. The loaded polymersomes were then attached to the ends of the secondary aptamer through EDC/NHS coupling, followed by the addition of DMF to initiate the release of the methylene blue. The presence of methylene blue was detected using DPV in conjunction with a MWCNT modified GCE to produce a linear range of 1 aM to µM and a LOD of 0.73 aM; the sensing mechanism occurs via a "signal on". They proceeded to show no interference from the presence of haemoglobin and acceptable recoveries in human plasma. It would be advantageous for this work to explore the effect of other common interferents toward myoglobin, in addition to validation of their real sample work through the use of commercial ELISAs. An alternative detection methodology was presented by Ma and co-workers [233] , who used photoelectrochemistry for the detection of myoglobin. They cast Mn-doped CdS nanocrystal-sensitized 2D heterostructured g-C 3 N 4 -MoS 2 onto an ITO electrode to serve as the photoactive matrix. This heterostructured g-C 3 N 4 -MoS 2 effectively promoted electron transfer and resisted the recombination of electron-hole pairs, producing a high photocurrent response, with the Mn-doped CdS further increasing the obtained photocurrent. This surface was modified with myoglobin specific antibodies to form the capture part of a sandwich assay. They used this in conjunction with anti-myoglobin labelled CuO conjugates, which effectively quenched the photoelectrochemical response of the system through competition for the light-generated electrons, poor conductivity and steric hindrance. Using this methodology, they were able to detect myoglobin in the range of 1 pg mL −1 to 50 ng mL −1 , with a limit of detection of 0.42 pg mL −1 . They exhibited that this system had a high specificity and sensitivity in human serum samples, achieving RSD% of 6.1% and below. From inspection of Table 3 , there are a limited amount of BNP sensors with the majority, if not all utilising immunoassay technology, and with very few using aptamer approaches. The approaches utilise a range of electrode compositions from acetylcholinesterase(AChE)-labelled anti-BNP gold nanoparticles, through to antibody labelled zinc oxide nanorods. Landim and co-workers [238] developed an immunosensor utilising screen-printed carbon electrodes (SPCE) which supported carboxylic acid functionalized multi-walled carbon nanotubes, modified with cobalt phthalocyanine (CoPc); see Fig. 6A . The electrode is then modified by drop casting with ethylenediamine (EDA), anti-BNP and glycine and left to react for 2 h. The immunosensor is based on the cobalt redox couple, which is the basis of the electroanalytical signal, with additions of BNP binding with anti-BNP, the signal decreases ("signal off") due to the insulating nature of BNP antigen, blocking the kinetics of the interfacial electron transfer and preventing the electrochemical reduction of the CoPc, resulting in the decrease in the current [238] . The immunosensor was shown to measure BNP using LSV from 10 to 1000 ng L −1 with a LOD of 3 ng L −1 , which is lower than conventional ELISA immunoassay for BNP quantification (14 ng L −1 ). The authors An example of a sensor platform for BNP with an even lower LOD has been recently reported by Hu and co-workers [273] . They developed a novel enhanced photoelectrochemical platform based on the successive deposition of N-doped ZnO nanopolyhedra (N-ZnO NP) and protoporphyrin IX. The N-ZnO NP provided a low band gap of 2.6 eV and was utilised as the substrate to enhance the observed photocurrents. The sensing platform was produced through casting of protoporphyrin IX followed by the N-ZnO NP. The authors then cast a DNA aptamer onto the surface of the photoelectrochemical platform to produce an ultra-sensitive, label-free "signal-off" sensor. This exhibited a wide linear range from 1 pg mL −1 to 100 ng mL −1 , with an LOD of 0.14 pg mL −1 and validation in human serum samples. In the majority of cases, the reported sensors provide very low detection levels. A thorough summary of commercial testing kits has recently been published for BNP [285] and inspection of Table 3 reveals that the detection levels are lower than commercial kits, indicating that they hold promise to be used in clinical settings. However, in some cases, the assay time can be longer than commercial kits, which is an area of future research focus. The majority of sensors that have been developed to measure NT-proBNP are based on immunoassay with a limited amount using aptamer technology and none utilising the potential benefits of MIPs (see Table 3 ). Zhuo and coworkers [241] have reported an electrochemical sandwich immunosensor utilising a nano-structural gold and carbon nanotubes composite which provide immobilization sites for antibodies with gold nanochains and horseradish peroxidase (HRP) complex labelled secondary antibodies for signal amplification operating via a "signal on" mechanism; the sensor fabrication is shown in Fig. 7A . The signal amplification is based upon gold nanochains prepared by reducing a gold salt with ascorbic acid. The antibody was conjugated with the gold nanochains by simple stirring for 12 h, followed by centrifugation to remove excess reagents. HRP was then added to block the unmodified portion of the Au nanochains surface. The electrochemical platform comprises a gold macroelectrode onto which carbon nanotubes, synthesised by a chemical vapour deposition method, are immobilised. The nanotubes were acid treated to introduce carboxylic groups and then added into a solution containing a gold salt and electrochemically reduced to produce nanogold modified carbon nanotubes. Next, the addition of the antibody and BSA finishes the electrochemical platform. The immunosensor was shown to measure from 0.02 to 100 ng mL −1 with a LOD of 6 pg mL −1 using CV which would cover the ranges reported in the critically ill [63] . The sensor's composition was reported by the authors to give rise to the sensitive sensing of NT-proBNP due to the carbon nanotubes promoting electron transfer and increasing the current response to hydrogen peroxide while the gold nanochains have more active sites than gold nanoparticles; thus, gold nanochains can immobilize more HRP and the current response to H 2 O 2 is larger than that of the immunosensor using Au nanoparticles. No interference from cTnI, cTnT and cTnC were found, with the sensor found to be stable for up to 30 days. Esteban-Fernández de Ávila [243] have reported a novel amperometric magnetoimmunosensor using an indirect competitive format developed for the sensitive detection of NT-proBNP. Figure 7B shows a schematic representation of the sensor's construction which involves the covalent immobilization of the antigen onto carboxyl-modified magnetic beads (HOOC-MBs) activated with EDC and sulfo-NHS, with further incubation in a solution containing variable concentrations of the antigen and a fixed concentration of an HRPlabelled detection antibody. Target NT-proBNP compete for binding with the specific HRP-labelled secondary antibody and the immunoconjugate-bearing MBs are captured by a magnet placed under the surface of a disposable gold SPE. Using amperometry, the analytical signal is measured using TMB (3,3′,5,5′-tetramethylbenzidine), an electrochemical mediator. The immunosensor measures NT-proBNP over the range 0.12 to 42.9 ng mL −1 with a LOD of 0.02 ng mL −1 and was shown to successfully measure NT-proBNP in human serum samples [243] . Such a dynamic range means the technology would prove useful for NT-proBNP sensing in the critically ill [63] . This study was extended to measure both NT-proBNP and CRP in human serum samples [286] . Zhang et al. [247] have developed an immunosensor based on a ITO electrode modified with carboxylic multiwalled carbon nanotubes, which have themselves been modified with chitosan, gold nanodots and N-(aminobutyl)-N-(ethylisoluminol). This is then modified with glutaraldehyde, immobilised through an amide reaction between the amino group of N-(aminobutyl)-N-(ethylisoluminol) and the aldehyde group of the glutaraldehyde. Last, the NT-proBNP antibody is connected via an amide reaction between the aldehyde group of glutaraldehyde and the amino group of the antibody. Figure 7C overviews the various steps of the sensor fabrication. Using ECL, the sensor was able to measure NT-proBNP over the range 0.01 to 100 pg mL −1 with a low LOD of 3.86 fg mL −1 . The authors demonstrated the sensor selectivity by exploring the interferents cTnI, IgG, lysozyme, BSA which had little effect upon the sensors performance. The sensors performance was validated in human plasma samples and directly compared with ELISA giving comparable results, strongly suggesting that the developed sensor could be used for the quantitative analysis of NT-proBNP in real samples of human plasma. Such a dynamic range means the technology would prove useful for NT-proBNP sensing in the critically ill [63] . Chen and co-workers [261] have reported the development of a ratiometric immunosensor, the steps involved in its fabrication are shown in Fig. 7D . A GCE serves as the supporting electrode which is modified with PtCoNi hollow multi-branches nanostructures/ferrocene-grafted-ionic liquid. The PtCoNi hollow multi-branches nanostructures are fabricated via a hydrothermal method via mixing platinum, cobalt and nickel acetate salts with oleylamine and oleic acid under continuous ultrasonication followed but the addition of formaldehyde. The solution is then placed into an autoclave and reacted for 12 h at 190 degrees. Following this, they are washed and etched in acetic acid. The nanostructures are impressive and are composed of five or six hollow branches, with their length and width measured to be ~47 and 26 nm respectively. These PtCoNi hollow multi-branches nanostructures are drop cast onto a GCE after which the ferrocene-grafted-ionic liquid is also drop cast along with the antibody and last, BSA. The other part of the immunoassay is comprised of gold nanostars and Co-N-C nanosheets. The former is fabricated via a one-pot wet chemical reduction methodology where 5-hydroxymethyluracil is dissolved into water, adjusted to pH 10 with a gold salt added along with the reducing agent ascorbic acid, and stirred for 30 min. The final product was centrifuged and washed. The latter is obtained by a simple pyrolysis methodology. The gold nanostars, thionine and the Co-N-C nanosheets are mixed together in water, left overnight to incubate into a composite. The antibody is then added through dispersing this composite in phosphate buffer solution and leaving overnight. The immunosensor using DPV, which is a "signal on" sensor, was demonstrated to measure NT-proBNP over the range 0.001 to 10.0 ng mL -1 with a LOD of 0.35 pg mL -1 , which again has limited use in the setting of HF diagnosis or prognostication in ICU. The selectivity of the sensor was explored towards possible interferents of cTnI, creatine kinase isoenzymes, neuron-specific enolase, and alpha fetoprotein which only caused very small changes in the peak currents towards the analytical target NT-proBNP (less than 5% RSD) and was able to successfully measure NT-proBNP in human serum. The authors attributed the sensors excellent analytical performance to be due to a combination of factors, enhanced electron transport and increased surface area from utilising 3D hollow PtCoNi multi-branches and improved biocompatibility from using the ferrocene-grafted-ionic liquid [287] . A common theme, as can be seen in Table 3 , for the detection of this biomarker is the use of electrochemiluminescence (ECL). Li and co-workers [252] developed an ECL immunoassay based on the energy transfer from Luminol-Au@Fe 3 O 4 -Cu 3 (PO 4 ) 2 nanomaterials (ECL donor) to Au@ CuS-rGO (ECL acceptor). In this approach, the former is immobilised upon a GCE which is then modified with Ab 1 via incubation for 12 h, after which BSA is then immobilised upon rGO-Au@CuS-Ab 2 to form the sandwich type immunoreaction mechanism. While the authors do not provide an exact mechanism, it is thought that it originated from ECL resonance energy transfer (ECL-RET) where the electrode materials promote electron transfer to luminol [252, 288] . The immunosensor was able to measure from 0.5 pg mL −1 to 20 ng mL −1 with a LOD of 0.12 pg mL −1 . The authors validated their sensor in human serum and directly compared the results with ELISA which gave excellent agreement. In the above cases, and generally in biosensors, there is usually the incorporation of noble nanoparticles of various geometries and compositions, with generally the reason to increase electron transfer properties and provide binding sites. Indeed, at the nanoscale there are changes in the electronic structure and work has shown that reaction mechanism and kinetics differ at the nanoscale in comparison to the bulk [289] . The question of what type of nanoparticles provides the best electroanalytical sensor is a pertinent one. To this end, Beck et al. [259] explored a sandwich type assay for the detection of NT-proBNP, where a SPCE is modified with the capture Ab 1 label (via drop casting) and silver and gold nanoparticle Ab 2 labelled probes were explored and contrasted. The authors found that in both cases, NT-proBNP could be measured over the range 25 to 1000 ng mL −1 using DPV but found that through the use of silver nanoparticles, due to their greater electrochemical activity, they provide a six-times more sensitive assay [259] . The exploration of the geometry and composition of nanoparticles used in immunoassays should be a key future research direction. The detection of neurohumoral markers using electrochemical sensing platforms is sparce, with no examples found for the detection of MR-proADM or MR-proANP. This is an area that should be explored in future research. There have been some reports of electrochemical sensors for the detection of copeptin and that is where our attention turns next. In terms of electrochemical based sensors, there are very few. Yang et al. [275] reported an ultrasensitive electrochemical immunoassay for copeptin determination using an ITO electrode modified with a RGO-TiO 2 nanocomposite which is then in turn modified with Ab-copeptin/BSA via coupling with EDC/NHS; the TiO 2 is in the form of nanoparticles prepared via a hydrothermal technique. The immunosensor using EIS was explored in model solutions where it was observed that as the concentration of copeptin rises, the capacitance declines, possibly because of variation in the dielectric/blocking traits of the electrolyte-electrode interface caused by the interaction between the antigen and antibody. Analysis of the EIS signal gives rise to a linear range of 10 to 500 ng mL −1 (249 to 12,344 pmol L −1 ) with a LOD of 0.15 ng mL −1 (37.3 pmol L −1 ). The interferent of ascorbic acid, uric acid, glucose, zinc, copper, mercury and cadmium salts were studied with no effect upon the electrochemical signal. The immunoassay has potential but clearly needs further work to demonstrate any potential clinical uptake. Han and co-workers [276] developed an ECL immunoassay for the measurement of copeptin based upon luminescence immune-gold nanoassemblies. The ECL immunosensor is based upon an ITO electrode onto which Cu 2+ -cysteine complexes and N-(aminobutyl)-N-(ethylisoluminol) functionalized gold nanoparticles combined with chitosan were drop cast and allowed to dry. Onto this modified ITO surface, gold nanoparticle labelled antibodies are fabricated via electrostatic interaction as well as hydrophobic interactions and weak covalent interactions [276] . This approach requires adding the copeptin antibody to a solution of prepared gold nanoparticles (12 nm diameter) followed by incubation overnight. Following this, BSA is added, and the conjugate centrifuged and cleaned with water. The antibody functionalised gold nanoparticles are simply drop cast onto the electrode surface and allowed to dry and the sensor is then ready to use. The sensor is a "signal off" where in the presence of copeptin, the ECL signal reduces due to the formation of antibody-antigen complexes. The ECL immunoassay exhibited a linear range from 0.02 to 10 pmol L −1 with a LOD of 0.0005 pmol L −1 . The selectivity of the immunoassay was explored towards the interferents: Seven polypeptides and proteins including Y-H, 3Y-H, HGGG, MB, HAS, FABP and IgG, all at one order of magnitude higher than that of copeptin which indicated no detrimental effect upon the electrochemical signal. The authors went on to demonstrate the determination of copeptin in human serum with good recoveries (97.4-109.3%). Last, Qin et al. [277] reported the fabrication of a triethanolamine-functionalized Metallic Organic Framework (MOF) upon graphene oxide, both supported on a glassy carbon electrode which was then functionalised with anti-copeptin via modification with glutaraldehyde for 2 h after which the antibody was incubated via drop casting for 12 h. The next step was the addition of BSA and then, the sensor was ready to use via ECL Ru(bpy) 3 2+ redox probe. The linear range was from 5 pg mL -1 to 500 ng mL -1 (1.24 to 12,344 pmol L −1 ) with a LOD reported to correspond to 360 fg mL -1 (0.09 pmol L −1 ). The following interferents were explored upon the ECL signal GOx, human H-FABP, human cTnI, human IgG, l-cysteine, DA, and copeptin which were reported to have no effect; the authors demonstrated the successful determination of copetin in human serum with good recoveries (96-104%) . This target has scope for future develop based on aptamer and MIP technology. As with the previous section, there is very little published literature on the electrochemical detection of the markers of extracellular matrix remodelling. None were found for GDF-8 or GDF-15, and we suggest this to be a productive area of future research. There were some examples for GAL-3 and sST2 and that is where our attention turns first. There is limited literature on the electrochemical detection of sST2, see Table 3 , with some alternative detection methods explored [290]. Demirbakan and Sezgintürk reported a sST2 immunoassay using disposable graphite paper (GP) electrodes [279] . The authors took inspiration from the battery field where paper electrodes are common and have reported advantages which include: very low-cost, high electrical conductivity and practical immobilization methods. The GP utilised in this work is 0.3 mm thick with a size of 210 mm × 210 mm and was commercially purchased. The GP was modified with C 60 via drop-casting before incorporating carboxyl groups through the application of sulfuric acid. Following this they immobilised anti-sST2 with EDC/NHS and blocked the remaining surface with BSA. Using EIS they reported a linear range from 0.1 to 100 fg mL −1 , with a LOD of fg mL −1 and show that the sensor platform can be stored for 10 days at 4 ºC whilst only losing 4.48% of the performance. The sensor shows no interference from cysteine, heat shock protein, protein activated kinase 2 or TNF-α and was validated through the detection in human serum samples, achieving recoveries between 100 and 113.46%. Recently, Torrente-Rodríguez and co-workers described an electrochemical sandwich immunoassay for sST2 using SPEs [278] . They developed magnetic immunoconjugates through EDC/NHS coupling of capture antibodies onto the surface of commercially procured carboxylic acid-modified magnetic beads. Upon the binding of target sST2 and secondary antibody labelled with streptavidin and HRP was introduced to allow for a measurable signal using chronoamperometry which occurs via a "signal on" mechanism. This system required an incubation time of sST2 of 15 min, followed by an incubation time of 30 min for the secondary labelled antibodies. Using this methodology, they achieved a linear range between 76 and 2500 pg mL −1 , based on loading of 50 µg mL −1 of capture antibody, and a LOD of 26.7 pg mL −1 . The sensor was used to detect the presence of sST2 in 25-times diluted human plasma samples from healthy individuals, which exhibited no matrix effects. The results from this were validated against a commercial ELISA platform, where no statistically significant differences were observed. Although the approaches to sST2 detection described in the literature have achieved excellent sensitivities, efforts now need to focus on refining the technology for optimal detection within physiologically relevant concentrations [108, 111] . There have been a few recent reports on the development of electrochemical biosensors for the detection of Gal-3. The first by Tang and co-workers reported a sandwich type immunosensor that utilised various materials to enhance the sensor performance such as metal-organic frameworks (MOFs), AuNPs and nitrogen-doped graphene nanoribbons (N-GNRs) [283] . The GCE was modified with N-GNRs-Fe-MOFs@AuNPs; firstly, the N-GNRs were produced through mixing nitrogen-doped MWCNTs with H 2 SO 4 and H 3 PO 4 at 140 ºC followed by the addition of KMnO 4 at 65 ºC. The Fe-MOFs were produced separately [291] and decorated with AuNPs through reduction with NaBH 4 . The N-GNRs and Fe-MOFs@AuNPs were then combined through sonication and stirring then drop-cast onto the surface of the GCE, before being modified with the Gal-3 specific antibody and the remaining active surface blocked with BSA. The other half of the sandwich was a AuPt-methylene blue (AuPt-MB) nanocomposite whereby, the methylene blue was allowed to form micelles in a solution of HCl and dodecyltrimethylammonium bromide (DTAB), followed by the addition of HAuCl 4 and H 2 PtCl 6 to form the nanoparticles. The secondary antibody was incubated with these nanocomposites for 12 h at 4 ºC before further blocking with BSA to prevent non-specific adsorption. For the detection of Gal-3 a 6 µL sample was incubated onto the modified GCE surface for 1 h at 37 ºC, before incubation with the AuPt-MB-Ab 2 nanocomposite for a further 1 h at 37 ºC. Using DPV they reported a linear relationship for the detection of Gal-3 from 100 fg mL −1 to 50 ng mL −1 , achieving a LOD of 33.33 fg mL −1 . They attribute the performance of the platform to the synergistic effect of the N-GNRs-Fe-MOFs@AuNP and AuPt-MB, with the former providing good electrical conductivity and a larger electroactive surface area and the latter providing good biocompatibility, high loading of antibodies and good signal amplification. They tested the sensing platform in human serum achieving recoveries between 97.99 and 104.84%, further validating it against a commercial ELISA platform showing the sensor provided satisfying accuracy. Although promising, as the authors note, the production time of the sensor is too long for commercial use. Additionally, a cost analysis of the sensor would be useful as, there is a large number of different materials and the use of a GCE, which could be problematic for the transition to clinical care. Another sandwich immunoassay utilising methylene blue has been reported by Liu et al. [282] . They created their capture platform through drop-casting carboxyl graphene (CR) onto the surface of a GCE before electrochemically reducing it, conjugating the capture antibody through EDC/NHS coupling and finally, blocking the remaining surface with BSA. The secondary antibodies were attached to mesoporous silica nanoparticles along with AuNPs and MB. They utilise both the MB and AuNPs for the detection through using DPV to monitor the reduction of MB and ASV for the oxidation of the AuNPs. The detection using the Au required the use of aqua regia to give a well-defined anodic Au-stripping peak; however, it is difficult to see how this would be used in a clinical setting. Using the MB detection method, they achieved a linear range from 50 fg mL −1 to 500 ng mL −1 and a LOD of 2 fg mL −1 . They showed that the immunosensor production was reproducible over a batch of 30 electrodes, giving a RSD of 6.4%. Additionally, the sensor exhibited minimal interference from the presence of various other proteins and was shown to work in clinical serum samples, with the MB sensing method producing recoveries between 95.8 and 106%. Piguillem and co-workers described a sandwich assay for Gal-3 based on the use of commercially procured carboxylic acid modified magnetic beads (MBs), allowing for the electrochemical measurements to be performed in buffer solution rather than the more difficult blood samples [281] . Capture antibodies were conjugated to carboxyl modified MBs through EDC/NHS coupling followed by blocking with ethanolamine. These Ab-MBs were then incubated in a solution containing Gal-3, followed by further incubation with a detection Ab and then streptavidin-HRP. After all the incubations, the solutions were washed and stored in phosphate buffer, in which the amperometric measurements could be performed. For the measurements, this solution was dropped onto an SPCE surface and inserted into a solution of 1 mM hydroquinone, followed by the addition of H 2 O 2 and amperometric detection at -0.2 V (vs. Ag pseudoreference). Through this methodology, they achieved a linear detection range between 0.028 to 5 ng mL −1 and a LOD of 8.3 pg mL −1 . The production methodology had a RSD of 7.7% and was validated in clinical plasma samples from both health individuals and those that had experienced heart failure against commercial ELISAs. The authors continued to show the multiplex possibilities of this sensing platform, using a dual SPCE, for the detection of both Gal-3 and NT-proBNP in buffered samples. Finally, Cerqueira et al. [284] have recently reported a MIP based biosensor for the detection of Gal-3. The MIPS were formed onto the surface of a SPCE using CV electropolymerisation of the aminophenol monomer in the presence of Gal-3 protein (5 µg mL −1 ). The template was removed through incubation of a solution of oxalic acid (0.5 M) overnight, before thoroughly washing and storage in PBS. Detection of Gal-3 was achieved using EIS, with a dynamic range from 0.005 to 50 µg mL −1 . They showed that the sensor was capable of detecting Gal-3 in human serum samples, reporting an LOD 10 times lower than in buffer which is not explained. This sensor shows a glimpse of what can be achieved with MIPs for the development of these sensor platforms, and we expect further work to be published in this area. There are a significant number of reports of the development of electrochemical biosensors for inflammatory biomarkers due to the wide range of uses for them throughout healthcare, and not just as markers of cardiac dysfunction, see Table 4 . As such we will focus on the last 5 years for each marker discussed beginning with IL-6. From inspection of Table 4 , the majority of proposed electrochemical sensors for IL-6 are immunoassay based with some examples of aptamer and MIP based platforms. Tang and co-workers [292] reported a microfluidic immunoassay for the multiplexed detection of cancer biomarkers, including IL-6. In this work, they produced a 32-sensor array (8 electrodes per biomarker analysed) using gold electrodes modified first with a mercaptopropionic acid (MPA) self-assembled monolayer (SAM), followed by EDC/NHS coupling of the specific primary antibodies. The secondary antibodies and HRP tag were chemically attached to streptavidin-modified magnetic nanoparticles (300 nm) and drawn by a syringe into the fluidic chambers. Detection, operating via a "signal on" approach was achieved through the injection of hydroquinone and hydrogen peroxide into the microfluidic detector channels using individual syringes, with the resulting DV measurements staggered to account for the time delay in the multiplexer. Through the use of the multiplexer, they managed to connect 8 of their microfluidic devices together as one, allowing for the analysis of 256 sensors in a time of 30 min. The authors validated their results with internal controls by having 2 of every 8 sensors incorporate BSA instead of antibodies and then further validation through comparison to ELISAs. Examples such as this providing a large throughput of samples show promise for further development towards ICU settings. An alternative multi-marker approach is reported by Wei et al. [297] for the simultaneous detection of IL-6, IL-1β and TNF-α. They achieve this through the immobilisation of specific capture antibodies for the three analytes targeted onto the GCE surface through diazonium salt electrodeposition (Fig. 8A) . When the target has bound to the surface an incubation of the secondary antibody solution is performed for 30 min. This solution contained specific antibodies for the three targets, each tagged with a different redox probe; Nile blue (NB, -0.4 V) for IL-6, Methylene blue (MB, -0.2 V) for IL-1β and Ferrocene (Fc, + 0.2 V) for TNF-α. This allowed for a DPV signal to be obtained for each individual biomarker based on the appearance of the oxidation peak corresponding to that specific redox tag (Fig. 8A (left) ). Through this methodology, IL-6 was able to be detected in the range of 5 to 150 pg mL −1 with a detection limit of 5 pg mL −1 . There was no significant interference observed from the presence of BSA, IgG PSA and CA-125 and the results were further validated in mouse serum. This system doesn't meet the LOD requirements for identification of IL-6 in healthy individuals but could be used to indicate elevated levels in heart failure. From an ICU standpoint, the availability of such as a multi-senor would not only be useful for stratification in conditions such as HF and AMI, but would also be useful in the monitoring of other critical illnesses such as sepsis and COVID-19, provided its dynamic range was extended to accommodate those concentrations in excess of 50 ng mL −1 seen in septic patients [94] . Liu and co-workers [296] have reported a dual-responsive sandwich immunoassay that utilises both electrochemical and ECL for the detection of IL-6. They modified a GCE surface with a composite of TiO 2 anatase mesocages (AMCs) and a carboxy-terminated ionic liquid (IL), followed by the ECL probe Ru(bpy) 3 (II) and their IL-6 specific capture antibody. The AMCs and IL are utilised for immobilisation of high loadings of the other components. The mesocages were prepared by taking sodium dodecyl Fig. 8 A) Schematic of the sensor fabrication and representative DPV for the simultaneous immunosensing of multiple cytokines in serum. Reproduced and adapted with permission from ref [297] . Copyright American Chemical Society 2018. B) Schematic illustration of the immunosensor production and working mechanism based on porous carbon composites. Reproduced and adapted with permission from ref [311] . Copyright Elsevier 2021. C) Illustration of the synthesis procedure for NiCoO 2 @CeO 2 NBs, the preparation of the electrocatalytic labels and the fabrication of the immunosensor. Reproduced and adapted with permission from reference [304] . Copyright American Chemical Society 2020. D) (i,ii) TEM images of NiCoO 2 @CeO 2 NBs; (iii,iv) STEM image and elemental mapping of NiCoO 2 @CeO 2 NBs. Reproduced and adapted with permission from ref [304] . Copyright American Chemical Society 2020 sulfate dissolved in hydrochloric acid solution to which titanium (IV) isopropoxide was added and kept at 80 °C for 48 h under stirring; final products were obtained by centrifugation washed thoroughly with distilled water and dried at 60 °C overnight, and then calcined at 400 °C for 30 min in air to remove the residual organics. The second part of the sandwich assay is comprised of octahedral anatase mesocrystals (OAMs), functionalised with acid phosphatase (ACP), and HRP labelled secondary antibodies. The OAMs were synthesised by taking titanate nanowires dispersed in acetic acid and then transferred into a Teflon-lined stainless steel autoclave at 200 ºC for 48 h. The resulting precipitated was obtained by centrifugation and washed with distilled water and ethanol. The final product was attained by drying the precipitate at 60 ºC for 12 h and calcined at 400 ºC for 30 min to remove the residual organics. The OAM has high crystallinity, photoelectric activity, and a nano-porous structure for immobilisation. Using the electrochemical sensing methodology, they achieved a linear range between 10 fg mL −1 and 90 ng mL −1 , with a LOD of 0.32 fg mL −1 ; whereas using ECL they achieved a linear range between 10 ag mL −1 to 90 ng mL −1 and a LOD of 3.5 ag mL −1 . This was tested in human serum with good recoveries. This platform showed promise, however a new ECL probe would be required for commercialisation due to possible leaking of the Ru(bpy) 3 A non-sandwich immunoassay based system with an appropriate wide linear range (0-1200 pg mL −1 ) and low LOD (0.14 pg mL −1 ) was reported by Liu et al. [311] (Fig. 8B ). They utilised a hierarchical nanoporous mesoporous-carbon composite (NMC) decorated with AuNPs on a GCE as the base for their platform. The NMC was formed through SiO 2 -nanoparticle assisted sacrificial strategy, achieving an interconnected 3D network with high surface area for deposition of the AuNPs. The anti-IL-6 was then conjugated to the AuNPs through EDC/NHS coupling before blocking the remaining active surface with BSA. DPV was used for the detection of IL-6, with the proposed platform validated in human serum against commercially available ELISA kits producing recoveries from 82.1 to 117%. Cao and co-workers [304] used nanocubes as a high surface area component for loading of their secondary antibodies and as a detection element (Fig. 8C) . They used Ni 2+ exchange, calcination and the CeO 2 growth to produce NiCoO 2 @CeO 2 nanoboxes from ZIF-67 (a cobalt-based zeolitic imidazolate framework) (Fig. 8D) . These nanoboxes exhibit a catalytic effect toward the oxygen evolution reaction, which changed upon binding of the target analyte. The CeO 2 nanoparticles served a dual purpose of enhancing the catalytic effect and providing sites for facile surface immobilisation of the antibodies through ester-like bridging. The GCE surface itself was modified with carboxylated graphene followed by EDC/NHS coupling of anti-IL-6 and blocking with BSA. For detection, sample was incubated onto the electrode for 50 min followed by the secondary antibody and nanocube system for 50 min. OER testing at + 1.3 V (vs. SCE) was used for detection, measuring the amperometric response, achieving a linear range from 2.5 × 10 -5 to 10 ng mL −1 and a LOD of 7 fg mL −1 . The authors showed that this platform performed well (93.8%) for up to 30 days post fabrication and validated their results in human serum samples against a commercial ELISA kit, achieving recoveries between 95.5 and 104%. For this system to be suitable for commercial uptake the two-step incubation times would need to be reduced from the current 1 h 40 min. Last, Tanak and co-workers have reported a multiplex system for cytokine detection, including IL-6, IL-8, IL-10, TRAIL and IP-10 in undiluted plasma samples in 5 min [309] . They fabricated their sensing platform through RF magnetron sputtering of a semi-conducting ZnO layer (200 nm) onto gold surfaces, followed by antibody immobilisation and blocking using commercial SuperBlock (blocking buffer) used to hydrolyse unbound linker sites to avoid non-specific interaction. The ZnO film was used due to its large band gap (3.367 eV) and high excitation binding energy (60 eV) which both aid in increasing sensitivity. Additionally, the ZnO is non-toxic, has high adsorption, is chemically stable and possesses good electrical conductivity. EIS was used for the detection of specific binding between the antigen and antibody, achieving detection in a wide linear range of 0.01 pg mL −1 to 10 ng mL −1 , with an LOD of 0.1 pg mL −1 for IL-6. They validated their results in pooled human blood plasma achieving a clinically accepted standard and an %RSD of ~ 10%, measured across 12 identical sensors. Further validation was obtained through the measurement of 40 patient samples (20 septic, 20 control) achieving a Pearson's r value ≥ 0.9. This system shows the sort of validation required to provide confidence to professionals working outside of the electrochemical field. From inspection of Table 4 , there is a wide variety of reported CRP electrochemical sensing platforms producing significantly different operational ranges due to the high concentrations of CRP present, see Table 1 . As such, most reports in literature work through identifying the optimal detection ranges for their sensing platform and then diluting the samples for analysis by the appropriate factors. One such example is reported by Vilian and co-workers [323] , who utilise a 100-fold dilution in the human serum samples for analysis. They report a simple immunosensor based on the formation of a 3-mercaptopropionic acid (MPA) SAM, followed by EDC/NHS coupling to the CRP antibody (Fig. 9A) . The proposed sensor produced a linear range of 5 to 220 fg mL −1 with a low LOD of 2.25 fg mL −1 , which is attributed to the gold nanowires grown on a polycarbonate surface. This gold surface was prepared through nanoimprint lithography using a customised electron beam evaporator, producing an Au film of 20 nm thickness (Fig. 9B) . Detection of CRP was achieved through SWV of the [Fe(CN) 6 ] 3−/4− redox couple, which exhibited a reduction in peak current ("signal off") on increasing amounts of CRP. For real sample analysis, human blood serum was diluted 100-fold in buffer solution and subsequently spiked with varying amounts of CRP, with a LOD of 4.5 fg mL −1 achieved in this medium. Additionally, CRP detection was achieved in human saliva solutions using EIS, through a tenfold dilution in PBS (0.1 M), producing a LOD of 4 fg mL −1 . Molinero-Fernández and co-workers have described micromotor sandwich based immunoassays for the detection of CRP in preterm infant plasma [333, 335] . Micro (or nano) motors convert an external stimulus into autonomous propulsion and when used in a biosensing application this allows them to travel around a sample scavenging for the target analyte. They demonstrated the micromotors can be formed using rGO, MWCNT or carbon black (CB), with the rGO based systems producing the most efficient and reproducible functionalisation [333] . The formation of the micromachines uses a combination of rGO, Ni and PtNPs, shown in Fig. 9C . In this way, the rGO acts as functionalisation points for the CRP antibodies, the Ni layer allows for the magnetic guidance and the PtNPs provide an inner catalytic layer. Using these systems in conjunction with a microfluidic set-up and amperometric detection they were able to detect CRP between 1 and 100 µg mL −1 with a LOD of 0.54 µg mL −1 . They used this to analyse CRP levels in preterm infant clinical samples with suspected sepsis, achieving readings using less than 10 µL sample volume in only 8 min [335] . These low sample volumes and quick turn-around time indicate the possibility of translation of this technology into clinical care. An alternative methodology was presented by Szot-Karpińska et al. [327] , who utilised bacteriophages as their recognition element. They immobilised these negatively charged bacteriophages onto a GCE surface in a layer-by-layer Fig. 9 A) Schematic showing the fabrication of the gold wire sensor for CRP along with the detection strategy. Reproduced and adapted with permission from ref [323] . Copyright Elsevier 2019. B) Scanning electron microscopy images obtained at various magnifications of the Au/PC substrate used for the gold wire CRP sensor. Reproduced and adapted with permission from ref [323] . Copyright Elsevier 2019. C) Schematic of the preparation of rGO/Ni/PtNPs micro-motors and their functionalisation with anti-CRP capture antibodies alongside SEM and EDX analysis (left), fluorescence microscopy images of the micromotors with and without streptavidin (right middle) and time-lapse images of the movement of the micromotors (right bottom). Reproduced and adapted with permission from ref [335] . Copyright American Chemical Society 2020 fashion with positively charged carbon nanofibers through electrostatic interactions. They compared systems with and without carbon nanofibers, showing that the biosensor using the CRP binding bacteriophage in conjunction with the nanofibers produced the best response, achieving a linear range of 4 to 40 µg mL −1 using three layers of the modification. They propose the use of phages as an artificial alternative to the traditional use of antibodies. We note that there are not many published works for the use of MIPs as another option for the replacement of antibodies with a more stable synthetic receptor. It is suggested this could be an area of research that is explored for CRP as the detection levels do not require the same sensitivities as many other biomarkers highlighted in this review. Lastly, Cheng and co-workers have explored utilising the synergistic effect of AuNPs and melamine signal amplification through the use of a ferrocene modified small molecular peptide (Fc-ECG) as the bio-recognition element [339] . AuNPs were deposited onto the surface for carbon based SPEs via electrochemical deposition from a aqueous solution containing a gold salt, followed by the dropwise addition of melamine and then formation of Au-S bonds between the NPs and the Fc-ECG. The sensor worked through the free thiol group on the Fc-ECG binding with CRP to form larger complexes and inhibiting electron transfer from the ferrocene tag which produces a "signal off" sensor. Using DPV a linear range of 1 to 550 µg mL −1 was obtained with a LOD or 0.3 µg mL −1 , achieving an %RSD of 4% in serum samples with good stability over 5 days post-production. For commercial uptake into clinical settings however a sensor lifetime longer than this would be required to reduce costs and wastage of tests. As seen for the inflammatory markers above, on inspection of Table 4 , there are a number of significant papers for the detection of TNF-α due to its association with a wide range of conditions. Peng and co-workers [356] have reported a versatile ECL based sensing platform utilising a GCE modified with gold nanoclusters (AuNC) and MnO 2 (Fig. 10A) . The AuNC were synthesized by dissolving a gold salt into sodium hydroxide with the reducing agent N-acetyl-L-cysteine. The mixture was incubated at 37 °C for 2.5 h, obtaining a colourless solution. The solution after synthesis was subject to dialysis for more than 24 h to remove all small-molecular impurity. MnO 2 was introduced by modifying a GCE with the AuNC and electrodepositing MnO 2 from immersing the electrode into a KMnO 4 acidic solution and holding the potential at − 0.2 V for 300 s by chronoamperometry. They use an ECL-resonance-energy-transfer (RET) strategy, whereby the AuNC is the ECL donor and the MnO 2 acts as the ECL acceptor. As seen in Fig. 10A , an ELISA based protocol is performed separately using antibodies functionalised with streptavidin and alkaline phosphatase. After the capture followed by enzymatic reaction has occurred, the resultant solution was collected and the modified GCE then incubated for 4 min. This platform achieved a linear response to TNF-α of 0.06 to 31 pg mL −1 with a LOD of 36 fg mL −1 , which corresponds to a reduction in two orders of magnitude compared to commercial ELISA kits. They attribute the excellent performance of their sensor to the independence between the ELISA and ECL parts of the system, separating the sensing interface from the complex practical samples, in addition to the dual-signal amplification provided by the ECL technology and enzyme catalysed signal amplification. The biofouling of electrodes is a common problem in the development of biosensing platforms, an alternative method to the separation of protocols mentioned above is the incorporation of anti-biofouling layers on the electrode. ing the development of an MBs-based immune-platform for the dual amperometric detection of RANKL and TNF at dual SPCEs. Reproduced and adapted with permission from ref [358] . Copyright Elsevier 2020 Jiang et al. [343] report using mixed layers of phosphorylcholine (PPC) and phenyl butyric acid (PBA) for the development of a TNF-α sensor in whole blood samples on an ITO electrode. In this zwitterionic mixed layer the PPC is responsible for repelling the non-specific protein adsorption that plagues many electrochemical biosensors, whereas the PBA allows for the bioconjugation of antibodies to the electrode surface. The authors then use a sandwich assay ("signal on") in which the secondary antibody is labelled with HRP for amperometric determination of the presence of the antigen. Using this protocol, they achieved a linear relationship between the current response and TNF-α concentration between 0.01 and 500 ng mL −1 with a lowest detected concentration of 10 pg mL −1 . They validated their sensor in whole blood against a commercial ELISA kit showing variations between 2.6 and 11.7%. Valverde and co-workers reported the dual detection of two emerging biomarkers related to breast cancer, of which TNF-α is one [358] . They utilise an SPCE with two working electrodes, dropping the appropriate solution on each electrode respectively, Fig. 10B . This system utilises a sandwich immunoassay where the capture antibodies are immobilised onto neutravidin-modified magnetic beads, and detection antibodies are labelled with HRP. The binding of the antibodies to the target is achieved separate from the electrode surface in a centrifuge tube. After incubation, the solutions were washed and resuspended in buffer solution before being placed on the working electrodes. Amperometric measurements were used to achieve a dynamic range of 9.9 to 1,000 pg mL −1 for TNF-α, with a LOD of 3 pg mL −1 . Their results were validated against a commercial ELISA, showing favourable results. The authors also show that the sensing platform can be stored at 4 ºC for 20 days with no significant differences observed in the sensitivities and there is no significant interference from a wide range of possible competitors. Their results were further validated against commercial ELISAs in human serum samples showing excellent agreement. Electrochemical approaches to PoC measurement of CBs in the critical care setting are extremely attractive given their speed, sensitivity, economy of production and ease of multipanel integration. However, it is important to note that assay cut-offs have not been clearly established in this diverse patient population, and measurements during dynamic critical illness may be problematic. CB interpretation may also vary depending on individual patient characteristics and underlying illness. From the literature on the design of the electrochemical sensing platforms, it is apparent that emphasis needs to be placed on the analysis procedure and time, production costs and storage life to provide added confidence in the technology. Most reports provide good validation for their work through measurements in real samples (human serum and plasma) and against commercial ELISAs, highlighting the promise of these technologies. The majority of work still utilises antibodies as their recognition elements and further work is expected toward using synthetic or man-made recognition elements to improve the batch-to-batch reproducibility, chemical and thermal stabilities, whilst also reducing the associated ethical concerns. Additionally, we suggest the increased development of multiplexed sensing platforms to further enhance the possibility of commercial uptake of these technologies. As discussed, there are many markers that, although not specific for cardiac diseases, can be utilised in conjunction with the gold standard markers to provide crucial information to clinicians. In addition to increasing the confidence in the reported results, this will help to increase interest in the technology from external sources leading to increased chances of further funding or commercialisation. Future research should be directed to emerging immuno-thrombotic markers shown to be important in the diagnosis of cardiac diseases such as D-dimer and P-selectin [362] [363] [364] , where electrochemical methods are currently limited [365] [366] [367] [368] [369] [370] . In this review, we outline the importance of rapid testing for CBs in critically ill patients, explaining the urgent need for developments in rapid, portable and sensitive sensing platforms. We highlight current gold standards used within clinical care in addition to discussing emerging CBs and their potential use in future, data driven patient care. We provide the sources of these CBs, along with their clinical relevance and desired analytical ranges found throughout the literature as reference points for future research on these CBs. We summarise the literature reported on the development of electrochemical sensing platforms for these CBs, focussing on the last 5 years for the most popular CBs, such as cTn's. Additionally, we explore in detail some of the interesting recent developments for each CB, highlighting how the platforms are produced, function and what key characteristics they possess. Finally, the review offers insights on where we see the field developing and what needs to happen to improve confidence in these platforms and increase the chances of commercialisation and uptake into critical care, particularly with respect to ensuring that the technology focuses on wider dynamic ranges for measurement in this unique cohort of patients. The confounding effects of age, gender, serum creatinine, and electrolyte concentrations on plasma B-type natriuretic peptide concentrations in critically ill patients Increased B-type natriuretic peptide (BNP) level is a strong predictor for cardiac dysfunction in intensive care unit patients Mechanisms of sepsis-induced cardiac dysfunction Cardiac dysfunction after burns Cardiac Dysfunction in Adult Patients with Traumatic Brain Injury: A Prospective Cohort Study Patterns and early evolution of organ failure in the intensive care unit and their relation to outcome Monitoring cardiac function in intensive care The influence of cardiac diastole on weaning from mechanical ventilation Use of N-terminal pro-brain natriuretic peptide to detect acute cardiac dysfunction during weaning failure in difficult-to-wean patients with chronic obstructive pulmonary disease Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid: single biomarker re-derivation and external validation in three cohorts A FABP-ulous 'rule out' strategy? Heart fatty acid binding protein and troponin for rapid exclusion of acute myocardial infarction Current Use of Cardiac Biomarkers in Various Heart Conditions Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays Biomarkers for heart failure: small molecules with high clinical relevance Tolvaptan for heart failure, systematic review and meta-analysis of trials Transaminase activity in human blood Cardiac troponin I as an early prognosis biomarker after trauma: a retrospective cohort study The prognostic significance of troponin elevation in patients with sepsis: A metaanalysis Cardiac troponin I as a prognostic factor in critically ill pneumonia patients in the absence of acute coronary syndrome Cardiac Troponin I association with critical illness and death risk in 726 seriously ill COVID-19 patients: A retrospective cohort study Cardiac troponin I: the gold standard in acute myocardial infarction diagnosis Clinical significance of plasma levels of brain natriuretic peptide and cardiac troponin T in patients with sepsis Serum troponin T measurement in patients with chronic renal impairment predicts survival and vascular disease: a 2 year prospective study Elevated B-type natriuretic peptide (BNP) and soluble thrombomodulin (sTM) indicates severity and poor prognosis of sepsis Cardiac biomarkers are associated with maximum stage of acute kidney injury in critically ill patients: a prospective analysis Dynamic detection of N-terminal pro-B-type natriuretic peptide helps to predict the outcome of patients with major trauma Multi-marker approach using procalcitonin, presepsin, galectin-3, and soluble suppression of tumorigenicity 2 for the prediction of mortality in sepsis Soluble ST2 Has a Prognostic Role in Patients With Suspected Sepsis Relationship between heart-type fatty acid-binding protein levels and the risk of death in patients with serious condition on arrival at the emergency department NICE (2020) High-sensitivity troponin tests for the early rule out of NSTEMI Cardiac Troponin I Associated with Poor Prognosis and 142 Death Risk in 726 Severe and Critical COVID-19 Patients: A Retrospective Cohort Study Cardiac troponin I levels are a risk factor for mortality and multiple organ failure in noncardiac critically ill patients and have an additive effect to the APACHE II score in outcome prediction Cardiac Troponin Measurement in the Critically Ill: Potential for Guiding Clinical Management Elevation of cardiac troponin I indicates more than myocardial ischemia Limit of detection of troponin discharge strategy versus usual care: randomised controlled trial Troponin in critically ill patients Clinical Evaluation of Point-of-Care-Testing of Heart-Type Fatty Acid-Binding Protein (H-FABP) for the Diagnosis of Acute Myocardial Infarction Heart Fatty Acid Binding Protein (H-FABP) as a Diagnostic Biomarker in Patients with Acute Coronary Syndrome Risk stratification of acute pulmonary embolism based on clinical parameters, H-FABP and multidetector CT Plasma heart-type fatty acid binding protein is superior to troponin and myoglobin for rapid risk stratification in acute pulmonary embolism Prognostic value of serum heart-type fatty acid-binding protein in patients with sepsis: A protocol for systematic review and meta-analysis Admission biomarkers of trauma-induced secondary cardiac injury predict adverse cardiac events and are associated with plasma catecholamine levels Utility of Heart-type Fatty Acid Binding Protein as a New Biochemical Marker for the Early Diagnosis of Acute Coronary Syndrome Human heart-type fatty-acid-binding protein as a point-of-care test in the early diagnosis of acute myocardial infarction Heart-type fatty acid binding protein in early diagnosis of myocardial infarction in the era of highsensitivity troponin: a systematic review and meta-analysis Early Diagnostic Performance of Heart-Type Fatty Acid Binding Protein in Suspected Acute Myocardial Infarction: Evidence From a Meta-Analysis of Contemporary Studies Diagnostic and prognostic value of H-FABP in acute coronary syndrome: Still evidence to bring The prognostic impact of the serum heart-type fatty acid-binding protein level in patients with sepsis who were admitted to the non-surgical intensive-care unit Serum creatinine phosphokinase in acute myocardial infarction: diagnostic value Serum CK-MB, COVID-19 severity and mortality: An updated systematic review and meta-analysis with meta-regression Creatine kinase Mb (CKMB) Cardiac markers-facilitating diagnosis and exclusion of patients with acute coronary syndrome The prognostic value of myoglobin difference in sepsis related chronic critical illness Myoglobin and troponin as prognostic factors in patients with COVID-19 pneumonia Myocardium injury biomarkers predict prognosis of critically ill coronavirus disease 2019 (COVID-19) patients 12 -Cardiac Markers B-type natriuretic peptide (BNP) and N-terminal-proBNP for heart failure diagnosis in shock or acute respiratory distress Implications of cardiac markers in risk-stratification and management for COVID-19 patients B-Type Natriuretic Peptide 60. NICE (2018) Chronic heart failure in adults: diagnosis and management NT-proBNP: The Gold Standard Biomarker in Heart Failure Pulmonary embolism: CT signs and cardiac biomarkers for predicting right ventricular dysfunction N-terminal-pro-BNP in critically ill patients with acute respiratory failure: a prospective cohort study Natriuretic peptide type B in burn intensive care Prognostic Value of Plasma N-Terminal Pro-Brain Natriuretic Peptide in Patients With Severe Sepsis Mid-regional pro-adrenomedullin in patients with acute dyspnea: Data from the Akershus Cardiac Examination (ACE) 2 Study Mid-region pro-hormone markers for diagnosis and prognosis in acute dyspnea: results from the BACH (Biomarkers in Acute Heart Failure) trial Superior accuracy of mid-regional proadrenomedullin for mortality prediction in sepsis with varying levels of illness severity Prognostic value of mid-regional pro-adrenomedullin (MR-proADM) in patients with community-acquired pneumonia: a systematic review and meta-analysis MR-proADM to detect specific types of organ failure in infection Pooled analysis of mid-regional pro-adrenomedullin values in COVID-19 patients with critical illness Midregional proadrenomedullin (MR-ProADM) reference values in serum Pro-atrial natriuretic peptide (pro-ANP) level in patients with severe sepsis and septic shock: prognostic and diagnostic significance Pro-atrial natriuretic peptide is a prognostic marker in sepsis, similar to the APACHE II score: an observational study Prognostic value of midregional pro-atrial natriuretic peptide in ventilator-associated pneumonia Midregional pro-atrial natriuretic peptide as a biomarker of left ventricular systolic dysfunction in patients with sepsis Comparison of midregional pro-atrial and B-type natriuretic peptides in chronic heart failure: influencing factors, detection of left ventricular systolic dysfunction, and prediction of death Midregional Pro-Atrial Natriuretic Peptide and Outcome in Patients With Acute Ischemic Stroke Elevated MR-proANP plasma concentrations are associated with sepsis and predict mortality in critically ill patients Use of copeptin for rapid rule-out of acute myocardial infarction Hepcidin levels predict nonresponsiveness to oral iron therapy in patients with iron deficiency anemia Clinical relevance of copeptin plasma levels as a biomarker of disease severity and mortality in critically ill patients Copeptin, a stable peptide of the arginine vasopressin precursor, is elevated in hemorrhagic and septic shock Prognostic role of copeptin after traumatic brain injury: A systematic review and meta-analysis of observational studies Cytokines and Cytokine Receptors in Advanced Heart Failure Role of Inflammation in Heart Failure The clinical significance of interleukin-6 in heart failure: results from the BIOSTAT-CHF study Plasma concentrations of interleukin-6, organ failure, vasopressor support, and successful coronary revascularization in predicting 30-day mortality of patients with cardiogenic shock complicating acute myocardial infarction Interleukin-6 in Covid-19: A systematic review and meta-analysis Can emerging biomarkers of myocardial remodelling identify asymptomatic hypertensive patients at risk for diastolic dysfunction and diastolic heart failure? Cytokine Levels in Critically Ill Patients With COVID-19 and Other Conditions C-Reactive Protein Increase in Unstable Coronary Disease Relationship of high sensitivity C-reactive protein with cardiac biomarkers in patients presenting with acute coronary syndrome C-reactive protein during and after myocardial infarction in relation to cardiac injury and left ventricular function at follow-up Association of Cardiac Injury With Mortality in Hospitalized Patients With COVID-19 in Wuhan A comparison study between wide-range and high-sensitivity C-reactive protein assays (Roche Cobas c702) for low C-reactive protein concentration in patients with cardiovascular risk Immature platelet indices alongside procalcitonin for sensitive and specific identification of bacteremia in the intensive care unit C-reactive protein as a marker of infection in critically ill patients The predictive prognostic values of serum TNF-α in comparison to SOFA score monitoring in critically ill patients Associations of circulating TNFα and IL-18 with myocardial infarction and cardiovascular risk markers: The Glasgow Myocardial Infarction Study Heart failure and anti tumor necrosis factor-alpha in systemic chronic inflammatory diseases TNFα in ischemia/reperfusion injuryand heart failure The Utility of Point of Care Test for Soluble ST2 in Predicting Adverse Cardiac Events during Acute Care of ST-Segment Elevation Myocardial Infarction Usefulness of soluble concentrations of interleukin family member ST2 as predictor of mortality in patients with acutely decompensated heart failure relative to left ventricular ejection fraction ST2 Predicts Mortality and Length of Stay in a Critically Ill Noncardiac Intensive Care Unit Population Prognostic and diagnostic value of plasma soluble suppression of tumorigenicity-2 concentrations in acute respiratory distress syndrome Clinical and Prognostic Significance of sST2 in Heart Failure Analytical and clinical evaluation of a novel high-sensitivity assay for measurement of soluble ST2 in human plasma-the Presage ST2 assay Association of galectin-3 and fibrosis markers with long-term cardiovascular outcomes in patients with heart failure, left ventricular dysfunction, and dyssynchrony: insights from the CARE-HF (Cardiac Resynchronization in Heart Failure) trial Galectin-3 is an independent marker for ventricular remodeling and mortality in patients with chronic heart failure Galectin-3, a marker of cardiac fibrosis, predicts incident heart failure in the community Galectin-3 as prognostic biomarker in patients with COVID-19 acute respiratory failure Multicenter determination of galectin-3 assay performance characteristics: Anatomy of a novel assay for use in heart failure Predictive value of plasma galectin-3 levels in heart failure with reduced and preserved ejection fraction Increased plasma myostatin in heart failure Growth Differentiation Factor-8 (GDF8)/Myostatin is a Predictor of Troponin I Peak and a Marker of Clinical Severity after Acute Myocardial Infarction Predictive value of serum myostatin for the severity and clinical outcome of heart failure Myostatin from the heart: local and systemic actions in cardiac failure and muscle wasting Prognostic role of GDF-15 across the spectrum of clinical risk in patients with NSTE-ACS Biomarkers in Relation to the Effects of Ticagrelor in Comparison With Clopidogrel in Non-ST-Elevation Acute Coronary Syndrome Patients Managed With or Growth Differentiation Factor-15 Is a Predictor of Mortality in Critically Ill Patients with Sepsis Growth differentiation factor-15 and prognosis in acute respiratory distress syndrome: a retrospective cohort study Growth differentiation factor-15 for prognostic assessment of patients Page 41 of with acute pulmonary embolism Levels of Growth Differentiation Factor 15 and Early Mortality Risk Stratification in Cardiogenic Shock GDF15: emerging biology and therapeutic applications for obesity and cardiometabolic disease Growth differentiation factor 15 for risk stratification and selection of an invasive treatment strategy in non ST-elevation acute coronary syndrome Growth Differentiation Factor 15 at 1 Month After an Acute Coronary Syndrome Is Associated With Increased Risk of Major Bleeding High-sensitivity cardiac troponin t concentrations below the limit of detection to exclude acute myocardial infarction: a prospective evaluation Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers Biosensors for cardiac biomarkers detection: A review Cardiovascular disease detection using bio-sensing techniques Recent development of cardiac troponin I detection Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a review Fluorescent Immunoassays for Detection and Quantification of Cardiac Troponin I: A Short Review Detection platforms for point-of-care testing based on colorimetric, luminescent and magnetic assays: A review Nanomaterials-based Electrochemical Sensing of Cardiac Biomarkers for Acute Myocardial Infarction: Recent Progress Carbon nanotubes-based electrochemical (bio) sensors for biomarkers Recent advances in acoustic wave biosensors for the detection of diseaserelated biomarkers: A review A critical review on the use of potentiometric based biosensors for biomarkers detection Optical immunosensing of effective cardiac biomarkers on acute myocardial infarction Electrochemical nano-immunosensing of effective cardiac biomarkers for acute myocardial infarction Electrochemical biosensors based on nanofibres for cardiac biomarker detection: A comprehensive review Electrochemical cardiovascular platforms: Current state of the art and beyond MIPs for commercial application in low-cost sensors and assays -An overview of the current status quo Ultrasensitive nanostructure sensor arrays on flexible substrates for multiplexed and simultaneous electrochemical detection of a panel of cardiac biomarkers Multiplexed electrochemical detection of three cardiac biomarkers cTnI, cTnT and BNP using nanostructured ZnO-sensing platform Self-accelerated electrochemiluminescence emitters of Ag@ SnO2 nanoflowers for sensitive detection of cardiac troponin T Ultra-sensitive facile CdS nanocrystals-based electrochemical biosensor to detect myocardial infarction marker troponin Label-free Electrochemical Immunosensor for Cardiac Troponin T Based on Exfoliated Graphite Nanoplatelets Decorated with Gold Nanoparticles Disposable printed lateral flow electrochemical immunosensors for human cardiac troponin T New signal probe integrated with ABEI as ECL luminophore and Ag nanoparticles decorated CoS nanoflowers as bis-co-reaction accelerator to develop a ultrasensitive CTNT immunosensor A label-free cardiac troponin T electrochemiluminescence immunosensor enhanced by graphene nanoplatelets Label free electrochemical detection of cardiac biomarker troponin T using ZnSnO 3 perovskite nanomaterials A novel approach for electrical tuning of nano-textured zinc oxide surfaces for ultra-sensitive troponin-T detection Studies on an on/off-switchable immunosensor for troponin T A novel ultrasensitive immunosensor based on disposable graphite paper electrodes for troponin T detection in cardiovascular disease Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for cardiac biomarker detection An electrochemical troponin T aptasensor based on the use of a macroporous gold nanostructure Electrogenerated chemiluminescence biosensor array for the detection of multiple AMI biomarkers An ultrasensitive human cardiac troponin T graphene screen-printed electrode based on electropolymerizedmolecularly imprinted conducting polymer A graphene based-biomimetic molecularly imprinted polyaniline sensor for ultrasensitive detection of human cardiac troponin T (cTnT) Phairatana T (2020) A novel molecularly imprinted polymer PMB/ MWCNTs sensor for highly-sensitive cardiac troponin T detection Molecularly Imprinted Polymer/Anodic Aluminum Oxide Nanocomposite Sensing Electrode for Low-Concentration Troponin T Detection for Patient Monitoring Applications Characterization and Clinical Serum Test of a Molecular Imprinted Polymer (MIP)-Based Cardiac Troponin T Sensing Electrode for Patient Monitoring Applications Functionalized Graphene Quantum Dot Interfaced Electrochemical Detection of Cardiac Troponin I: An Antibody Free Approach Thionin functionalized signal amplification label derived dualmode electrochemical immunoassay for sensitive detection of cardiac troponin I Novel electrochemical immunosensor for sensitive monitoring of cardiac troponin I using antigen-response cargo released from mesoporous Fe3O4 Ultrasensitive sandwich-type immunosensor for cardiac troponin i based on enhanced electrocatalytic reduction of H 2 O 2 using β-cyclodextrins functionalized 3D porous graphenesupported Pd@Au nanocubes Porous graphene oxide nanostructure as an excellent scaffold for label-free electrochemical biosensor: detection of cardiac troponin I Electroactive graphene-multi-walled carbon nanotube hybrid supported impedimetric immunosensor for the detection of human cardiac troponin-I One step in-situ synthesis of amine functionalized graphene for immunosensing of cardiac marker cTnI Cardiac Troponin I: Ultrasensitive Detection Using Faradaic Electrochemical Impedance Novel peptidylated surfaces for interference-free electrochemical detection of cardiac troponin I High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors Label-free electrochemical impedance peptide-based biosensor for the detection of cardiac troponin I incorporating gold nanoparticles modified carbon electrode Electrochemical impedance analysis of biofunctionalized conducting polymer-modified graphene-CNTs nanocomposite for protein detection Fabrication of electrochemical immunosensor for cardiac biomarker troponin I determination and its potential for acute myocardial infarction diagnosis Paper based modification-free photoelectrochemical sensing platform with single-crystalline aloe like TiO2 as electron transporting material for cTnI detection A novel label-free photoelectrochemical sensor based on N, S-GQDs and CdS co-sensitized hierarchical Zn2SnO4 cube for detection of cardiac troponin I Label-free electrochemical immunosensor based on a functionalized ionic liquid and helical carbon nanotubes for the determination of cardiac troponin I Electrochemical Detection of Cardiac Biomarkers Utilizing Electrospun Multiwalled Carbon Nanotubes Embedded SU-8 Nanofibers An electrochemical sandwich immunosensor for cardiac troponin I by using nitrogen/sulfur co-doped graphene oxide modified with Au@ Ag nanocubes as amplifiers An electrochemical troponin I peptisensor using a triangular icicle-like gold nanostructure Facile Ratiometric Electrochemical Sensor for In Vivo/ Online Repetitive Measurements of Cerebral Ascorbic Acid in Brain Microdiaysate Electrochemical aptasensor of cardiac troponin I for the early diagnosis of acute myocardial infarction Highly sensitive amperometric detection of cardiac troponin I using sandwich aptamers and screen-printed carbon electrodes Microporous nanocomposite enabled microfluidic biochip for cardiac biomarker detection Electrochemical aptasensing of human cardiac troponin I based on an array of gold nanodumbbells-Applied to early detection of myocardial infarction Simple, low-cost, sensitive and label-free aptasensor for the detection of cardiac troponin I based on a gold nanoparticles modified titanium foil Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA nanotetrahedron structure Evaluation of molecular imprinted polymerized methylene blue/aptamer as a novel hybrid receptor for Cardiac Troponin I (cTnI) detection at glassy carbon electrodes modified with new biosynthesized ZnONPs The TDs/aptamer cTnI biosensors based on HCR and Au/Ti3C2-MXene amplification for screening serious patient in COVID-19 pandemic An ultrasensitive electrochemical sensing platform for the detection of cTnI based on aptamer recognition and signal amplification assisted by TdT A New Molecularly Imprinted Polymer (MIP)-based Electrochemical Sensor for Monitoring Cardiac Troponin I (cTnI) in the Serum Development of cardiac troponin-I biosensor based on boron nitride quantum dots including molecularly imprinted polymer MIPs-graphene nanoplatelets-MWCNTs modified glassy carbon electrode for the determination of cardiac troponin I Evaluation of molecular imprinted polymerized methylene blue/aptamer as a novel hybrid receptor for Cardiac Troponin I (cTnI) detection at glassy carbon electrodes modified with new biosynthesized ZnONPs Development of a disposable immunosensor for the detection of human heart fatty-acid binding protein in human whole blood using screen-printed carbon electrodes Development of an immunoassay for impedance-based detection of heart-type fatty acid binding protein A Sensitive capacitive immunosensor for direct detection of human heart fatty acid-binding protein (h-FABP) AuPt nanocrystals/polydopamine supported on open-pored hollow carbon nanospheres for a dual-signaling electrochemical ratiometric immunosensor towards h-FABP detection A highly sensitive electrochemiluminescence immunosensor for h-FABP determination based on self-enhanced luminophore coupled with ultrathin 2D nickel metal-organic framework nanosheets Electrochemical immunosensor development based on core-shell high-crystalline graphitic carbon nitride@carbon dots and Cd0.5Zn0.5S/ d-Ti3C2Tx MXene composite for heart-type fatty acid-binding protein detection Gold Nano/Micro-Islands Overcome the Molecularly Imprinted Polymer Limitations to Achieve Ultrasensitive Protein Detection Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples Novel sensory surface for creatine kinase electrochemical detection Immunosensor Employing Stable, Solid 1-Amino-2-naphthyl Phosphate and Ammonia-Borane toward Ultrasensitive and Simple Point-of-Care Testing Electrochemical quantification of CK-MB in serum based on immunoassay An ultra-sensitive label-free electrochemiluminescence CKMB immunosensor using a novel nanocompositemodified printed electrode Eco-friendly one-pot aqueous synthesis of ultra-thin AuPdCu alloyed nanowire-like networks for highly sensitive immunoassay of creatine kinase-MB Confining signal probe in porous PdPtCoNi@Pt-skin nanopolyhedra to construct a sandwich-type electrochemical immmunosensor for ultrasensitive detection of creatine kinase-MB Aptamer-based microfluidic electrochemical biosensor for monitoring cell-secreted trace cardiac biomarkers A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs) Cu-doped ZnO nanoparticles as an electrochemical sensing electrode for cardiac biomarker myoglobin detection Graphene-CNT nanohybrid aptasensor for label free detection of cardiac biomarker myoglobin Nanostructured aptamer-functionalized black phosphorus sensing platform for label-free detection of myoglobin, a cardiovascular disease biomarker A novel electrochemical aptasensor based on Y-shape structure of dual-aptamer-complementary strand conjugate for ultrasensitive detection of myoglobin Label-free, highly sensitive electrochemical aptasensors using polymer-modified reduced graphene oxide for cardiac biomarker detection Electrochemical detection of cardiac biomarker myoglobin using polyphenol as imprinted polymer receptor Electrosynthesis and binding properties of molecularly imprinted poly-o-phenylenediamine for selective recognition and direct electrochemical detection of myoglobin Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite Voltammetric myoglobin sensor based on a glassy carbon electrode modified with a composite film consisting of carbon nanotubes and a molecularly imprinted polymerized ionic liquid Preparation of Myoglobin Imprinted Polymer via Myoglobin Catalyzed-eATRP on the Surface of Foam-Graphene Development of novel aptasensor for ultra-sensitive detection of myoglobin via electrochemical signal amplification of methylene blue using poly (styrene)-block-poly (acrylic acid) amphiphilic copolymer Copper sulfide-functionalized molybdenum disulfide nanohybrids as nanoenzyme mimics for electrochemical immunoassay of myoglobin in cardiovascular disease Label-Free Electrochemical Sensor Based on Manganese Doped Titanium Dioxide Nanoparticles for Myoglobin Detection: Biomarker for Acute Myocardial Infarction Controlling intersheet-distance in reduced graphene oxide electrodes for highly sensitive electrochemical impedimetric sensing of myoglobin Gold nanoparticles-reduced graphene oxide based electrochemical immunosensor for the cardiac biomarker myoglobin CdS: Mn-sensitized 2D/2D heterostructured g-C3N4-MoS2 with excellent photoelectrochemical performance for ultrasensitive immunosensing platform Development of a sandwich enzyme-linked immunosorbent assay for the determination of human heart type fatty acid-binding protein in plasma and urine by using two different monoclonal antibodies specific for human heart fatty acid-binding protein Enzyme immunosensor for diagnosis of myocardial infarction Immunoelectrochemical Assay for Creatine Kinase Isoenzyme MB Screenprinted electrodes: Transitioning the laboratory in-to-the field An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry Application of a Fab fragment of monoclonal antibody specific to N-terminal pro-brain natriuretic peptide for the detection based on regeneration-free electrochemical immunosensor Ultrasensitive electrochemical strategy for NT-proBNP detection with gold nanochains and horseradish peroxidase complex amplification A novel microfluidic immunoassay system based on electrochemical immunosensors: An application for the detection of NT-proBNP in whole blood Disposable amperometric magnetoimmunosensor for the sensitive detection of the cardiac biomarker amino-terminal pro-B-type natriuretic peptide in human serum Nanosensor electrical immunoassay for quantitative detection of NT-pro brain natriuretic peptide A capacitive immunosensor using on-chip electrolytic pumping and magnetic washing techniques for point-of-care applications Luminescence-Functionalized Metal-Organic Frameworks Based on a Ruthenium(II) Complex: A Signal Amplification Strategy for Electrogenerated Chemiluminescence Immunosensors Sensitive immunosensor for N-terminal pro-brain natriuretic peptide based on N-(aminobutyl)-N-(ethylisoluminol)-functionalized gold nanodots/multiwalled carbon nanotube electrochemiluminescence nanointerface An ultrasensitive electrochemiluminescence immunosensor for NT-proBNP based on self-catalyzed luminescence emitter coupled with PdCu@carbon nanohorn hybrid Sandwich-Type Electrochemiluminescence Sensor for Detection of NT-proBNP by Using High Efficiency Quench Strategy of Fe3O4@PDA toward Ru(bpy)32+ Coordinated with Silver Oxalate A novel label-free photoelectrochemical immunosensor based on NCQDs and Bi2S3 co-sensitized hierarchical mesoporous SnO2 microflowers for detection of NT-proBNP Label-free photoelectrochemical immunosensor for NT-proBNP detection based on La-CdS/3D ZnIn2S4/Au@ZnO sensitization structure Electrochemiluminescence quenching of luminol by CuS in situ grown on reduced graphene oxide for detection of N-terminal pro-brain natriuretic peptide Novel electrochemiluminescent platform based on gold nanoparticles functionalized Ti doped BiOBr for ultrasensitive immunosensing of NT-proBNP Ultrasensitive Photoelectrochemical Biosensing Platform for Detecting N-Terminal Pro-brain Natriuretic Peptide Based on SnO2/SnS2/mpg-C3N4 Amplified by PbS/SiO2 Electrochemiluminescence immunoassay for the N-terminal pro-B-type natriuretic peptide based on resonance energy transfer between a self-enhanced luminophore composed of silver nanocubes on gold nanoparticles and a metal-organic framework of type MIL-125 An electrochemiluminescence immunosensor for the N-terminal brain natriuretic peptide based on the high quenching ability of polydopamine Immunosensing of NT-proBNP via Cu2+-based MOFs Biolabeling and in situ Microliter-droplet Anodic Stripping Voltammetry Highly-sensitive electrochemiluminescence biosensor for NT-proBNP using MoS2@Cu2S as signalenhancer and multinary nanocrystals loaded in mesoporous UiO-66-NH2 as novel luminophore Ag nanoparticles outperform Au nanoparticles for the use as label in electrochemical point-of-care sensors Electrochemical Detection of NT-proBNP Using a Metalloimmunoassay on a Paper Electrode Platform Ultrasensitive ratiometric electrochemical immunoassay of N-terminal pro-B-type natriuretic peptide based on threedimensional PtCoNi hollow multi-branches/ferrocene-graftedionic liquid and CoNC nanosheets Construction of high sensitivity electrochemiluminescence sensor and its application in nt-probnp detection Signalenhancer molecules encapsulated liposome as a valuable sensing and amplification platform combining the aptasensor for ultrasensitive ECL immunoassay Zeolite-iron oxide nanocomposite from fly ash formed a 'clubbell' structure: integration of cardiac biocapture macromolecules in serum on microelectrodes Sensitive determination of NT-proBNP for diagnosing abdominal aortic aneurysms incidence on interdigitated electrode sensor Surface electrochemical enzyme immunoassay for the highly sensitive measurement of B-type natriureric peptide Electrochemical enzyme immunoassay of a peptide hormone at picomolar levels Gold modified screen printed carbon electrode (SPCE) with steptavidin-biotin system for detection of heart failure by using immunosensor Paper-based microfluidic immunoassay for electrochemical detection of B-type natriuretic peptide Development toward a triple-marker biosensor for diagnosing cardiovascular disease Dual mode competitive electrochemical immunoassay for B-type natriuretic peptide based on GS/SnO 2 /polyaniline-Au and ZnCo 2 O 4 /N-CNTs Towards label-free, wash-free and quantitative B-type natriuretic peptide detection for heart failure diagnosis The enhanced photoelectrochemical platform constructed by N-doped ZnO nanopolyhedrons and porphyrin for ultrasensitive detection of brain natriuretic peptide Using SiO2/PDA-Ag NPs to dual-inhibited photoelectrochemical activity of CeO2-CdS composites fabricated a novel immunosensor for BNP ultrasensitive detection Development of an ultrasensitive electrochemical method for copeptin content determination Coreactant-Free and Label-Free Eletrochemiluminescence Immunosensor for Copeptin Based on Luminescent Immuno-Gold Nanoassemblies Situ Growing Triethanolamine-Functionalized Metal-Organic Frameworks on Two-Dimensional Carbon Nanosheets for Electrochemiluminescent Immunoassay Electrochemical Immunosensing of ST2: A Checkpoint Target in Cancer Diseases An impedimetric biosensor system based on disposable graphite paper electrodes: Detection of ST2 as a potential biomarker for cardiovascular disease in human serum Vargas-Berenguel A (2020) Multivalent Lactose-Ferrocene Conjugates Based on Poly (Amido Amine) Dendrimers and Gold Nanoparticles as Electrochemical Probes for Sensing Galectin-3. Nanomaterials Easily Multiplexable Immunoplatform to Assist Heart Failure Diagnosis through Amperometric Determination of Galectin-3 Dual-signal sandwich-type electrochemical immunoassay of galectin-3 using methylene blue and gold nanoparticles biolabels A sensitive sandwich-type immunosensor for the detection of galectin-3 based on N-GNRs-Fe-MOFs@ AuNPs nanocomposites and a novel AuPt-methylene blue nanorod Development of an electrochemical biosensor for Galectin-3 detection in point-of-care Multiplexed determination of amino-terminal pro-B-type natriuretic peptide and C-reactive protein cardiac biomarkers in human serum at a disposable electrochemical magnetoimmunosensor Ultrasensitive ratiometric electrochemical immunoassay of N-terminal pro-B-type natriuretic peptide based on threedimensional PtCoNi hollow multi-branches/ferrocene-graftedionic liquid and Co Electrogenerated chemiluminescence resonance energy transfer between luminol and CdS/graphene nanocomposites and its sensing application Thermal detection of cardiac biomarkers heart-fatty acid binding protein and ST2 using a molecularly imprinted nanoparticle-based multiplex sensor platform A novel non-invasive detection method for the FGFR3 gene mutation in maternal plasma for a fetal achondroplasia diagnosis based on signal amplification by hemin-MOFs/PtNPs High-throughput electrochemical microfluidic immunoarray for multiplexed detection of cancer biomarker proteins Multifunctional reduced graphene oxide (RGO)/Fe3O4/CdSe nanocomposite for electrochemiluminescence immunosensor Graphene oxide thin film with dual function integrated into a nanosandwich device for in vivo monitoring of interleukin-6 Development of Human Interleukin-6 electrochemical Immunosensor Based on Pt-Pd Nanocomposite for Evaluation of Intervertebral Disc Degeneration Combined electrochemiluminescent and electrochemical immunoassay for interleukin 6 based on the use of TiO 2 mesocrystal nanoarchitectures Graphene oxide signal reporter based multifunctional immunosensing platform for amperometric profiling of multiple cytokines in serum Photoelectrochemical immunoassay for human interleukin 6 based on the use of perovskite-type LaFeO 3 nanoparticles on fluorine-doped tin oxide glass Development of a needle shaped microelectrode for electrochemical detection of the sepsis biomarker interleukin-6 (IL-6) in real time Muscle-on-a-chip with an on-site multiplexed biosensing system for in situ monitoring of secreted IL-6 and TNF-α An antifouling coating that enables affinity-based electrochemical biosensing in complex biological fluids Impedimetric aptasensor for the label-free and selective detection of Interleukin-6 for colorectal cancer screening The development of an ultra-sensitive electrochemical immunosensor using a PPyr-NHS functionalized disposable ITO sheet for the detection of interleukin 6 in real human serums NiCoO2@ CeO2 Nanoboxes for Ultrasensitive Electrochemical Immunosensing Based on the Oxygen Evolution Reaction in a Neutral Medium: Application for Interleukin-6 Detection Highly sensitive impedimetric immunosensor for determination of interleukin 6 as a cancer biomarker by using conjugated polymer containing epoxy side groups modified disposable ITO electrode A novel electrochemical immunosensor based on acetylene black/epoxy-substituted-polypyrrole polymer composite for the highly sensitive and selective detection of interleukin 6 Electrochemical Point-of Care (PoC) Determination of Interleukin-6 (IL-6) Using a Pyrrole (Py) Molecularly Imprinted Polymer (MIP) on a Carbon-Screen Printed Electrode (C-SPE) Photoelectrochemical IL-6 Immunoassay Manufactured on Multifunctional Catecholate-Modified TiO2 Scaffolds Multiplexed cytokine detection using electrochemical point-of-care sensing device towards rapid sepsis endotyping Electrochemical Immunosensing of Interleukin-6 in Human Cerebrospinal Fluid and Human Serum as an Early Biomarker for Traumatic Brain Injury Nanoparticle-assisted sacrificial synthesis of hierarchical porous carbon composite for rapid sample enrichment and ultrasensitive label-free immunosensing of interleukin-6 biomarker Photogenerated Hole-Induced Chemical-Chemical Redox Cycling Strategy on a Direct Z-Scheme Bi2S3/Bi2MoO6 Heterostructure Photoelectrode: Toward an Ultrasensitive Photoelectrochemical Immunoassay Label-free and direct detection of C-reactive protein using reduced graphene oxide-nanoparticle hybrid impedimetric sensor Label-free detection of C-reactive protein Page using an electrochemical DNA immunoassay Label free C-reactive protein detection based on an electrochemical sensor for clinical application Single frequency impedance analysis on reduced graphene oxide screen-printed electrode for biomolecular detection Immunosensor for electrodetection of the C-reactive protein in serum Development of DNA aptamer-based sensor for electrochemical detection of C-reactive protein Occlusion phenomenon of redox probe by protein as a way of voltammetric detection of non-electroactive C-reactive protein Determination of C-reactive protein by PAMAM decorated ITO based disposable biosensing system: A new immunosensor design from an old molecule ZnO/porous carbon composite from a mixed-ligand MOF for ultrasensitive electrochemical immunosensing of C-reactive protein A C-reactive protein immunosensor based on platinum nanowire/titania nanotube composite sensitized electrochemiluminescence Efficient electron-mediated electrochemical biosensor of gold wire for the rapid detection of C-reactive protein: A predictive strategy for heart failure A folding affinity paper-based electrochemical impedance device for cardiovascular risk assessment Disposable paper-based electrochemical sensor using thiol-terminated poly (2-methacryloyloxyethyl phosphorylcholine) for the label-free detection of C-reactive protein An origami paper-based electrochemical immunoassay for the C-reactive protein using a screen-printed carbon electrode modified with graphene and gold nanoparticles CRP-binding bacteriophage as a new element of layer-by-layer assembly carbon nanofiber modified electrodes Reusable Immunosensor for Detection of C-reactive Protein in Human Serum Synthesis and structural optimization of iridium (III) solvent complex for electrochemiluminescence labeling of histidine-rich protein and immunoassay applications for CRP detection Bioactive multiple-bent MWCNTs for sensitive and reliable electrochemical detection of picomolar-level C-reactive proteins Reagentless redox capacitive assaying of C-reactive protein at a polyaniline interface An array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples On-the-fly rapid immunoassay for neonatal sepsis diagnosis: C-reactive protein accurate determination using magnetic graphene-based micromotors Electrochemical detection of C-reactive protein using functionalized iridium nanoparticles/graphene oxide as a tag Electrochemical microfluidic micromotors-based immunoassay for C-reactive protein determination in preterm neonatal samples with sepsis suspicion Nanostructured functional peptide films and their application in C-reactive protein immunosensors A low-cost electrochemical biosensor platform for C-reactive protein detection Electrochemical paper-based analytical device for multiplexed, point-of-care detection of cardiovascular disease biomarkers A synergistic effect of gold nanoparticles and melamine with signal amplification for C-reactive protein sensing A sensitive labelfree photoelectrochemical aptasensor based on a novel PTB7-Th/H2O2 system with unexpected photoelectric performance for C-reactive protein analysis Oriented antibody covalent immobilization for label-free impedimetric detection of C-reactive protein via direct and sandwich immunoassays Label-free selective detection of protein markers in the picomolar range via a convenient voltammetric sensing strategy Unique sensing interface that allows the development of an electrochemical immunosensor for the detection of tumor necrosis factor α in whole blood A sensitive electrochemical aptasensor for TNF-α based on bimetallic Ag@ Pt core-shell nanoparticle functionalized graphene nanostructures as labels for signal amplification Strategies for the development of an electrochemical bioassay for TNF-alpha detection by using a non-immunoglobulin bioreceptor Decoration of reduced graphene oxide nanosheets with aryldiazonium salts and gold nanoparticles toward a label-free amperometric immunosensor for detecting cytokine tumor necrosis factor-α in live cells Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double-walled carbon nanotubes An ultrasensitive photoelectrochemical immunosensor by integration of nanobody, TiO2 nanorod arrays and ZnS nanoparticles for the detection of tumor necrosis factor-α Potential-resolved electrochemiluminescence for simultaneous determination of triple latent tuberculosis infection markers Off surface matrix based on-chip electrochemical biosensor platform for protein biomarker detection in undiluted serum Electrochemical immunosensor for tumor necrosis factor-alpha detection in undiluted serum Voltammetric determination of tumor necrosis factor-α based on the use of an aptamer and magnetic nanoparticles loaded with gold nanoparticles A low-cost and miniaturized potentiostat for sensing of biomolecular species such as TNF-α by electrochemical impedance spectroscopy Novel nanostructured indium tin oxide electrode for electrochemical immunosensors: Suitability for the detection of TNF-α A novel chronoamperometric immunosensor for rapid detection of TNF-α in human saliva Versatile high-performance electrochemiluminescence ELISA platform based on a gold nanocluster probe Ultrasensitive electrochemiluminescence aptasensor for assessment of protein heterogeneity in small cell population Electrochemical immunoplatform to improve the reliability of breast cancer diagnosis through the simultaneous determination of RANKL and TNF in serum Cerium oxide nanofiber based electroanalytical sensor for TNF-α detection: Improved interfacial stability with Nafion Dual Signal-On" Split-Type Aptasensor for TNF-α: Integrating MQDs/ZIF-8@ ZnO NR Arrays with MB-Liposome-Mediated Signal Amplification Simple and facile carbon dots based electrochemical biosensor for TNF-α targeting in cancer patient's sample Diagnostic Value of D-Dimer in Acute Myocardial Infarction Among Patients With Suspected Acute Coronary Syndrome Targeting P-Selectin Adhesion Molecule in Molecular Imaging: P-Selectin Expression as a Valuable Imaging Biomarker of Inflammation in Cardiovascular Disease Prognostic Value of D-dimer in patients with acute coronary syndrome treated by percutaneous coronary intervention: a retrospective cohort study Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics Low-Cost and Desktop-Fabricated Biosensor for Rapid and Sensitive Detection of Circulating D-Dimer Biomarker Immunosensors Made with Layer-by-Layer Films on Chitosan/Gold Nanoparticle Matrices to Detect D-Dimer as Biomarker for Venous Thromboembolism Sensitive label-free electron chemical capacitive signal transduction for D-dimer electroanalysis A Selective Immunosensor for D-dimer Based on Antibody Immobilized on a Graphene Electrode with Incorporated Lipid Films Nanosilica based electrochemical biosensor: A novel approach for the detection of platelet-derived microparticles Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.