key: cord-0028023-efxkd0a1 authors: Desmond, Thomas; Tran, Vincent; Maharaj, Monish; Carnt, Nicole; White, Andrew title: Correction to: Diagnostic accuracy of AS-OCT vs gonioscopy for detecting angle closure: a systematic review and meta-analysis date: 2021-09-28 journal: Graefes Arch Clin Exp Ophthalmol DOI: 10.1007/s00417-021-05432-5 sha: ea60461d953c6cadfdc09745cfc28385479b36db doc_id: 28023 cord_uid: efxkd0a1 nan The authors would like to fully acknowledge that in error two incorrect statements were made. The first incorrect statement is: A Cochrane review by Jindal et al (2020) assessed noncontact tests for angle closure but did not compare against gonioscopy as a reference standard. A systematic review and meta-analysis that was published in the Cochrane Library in May 2020 [1] , evaluated a range of non-contact tests that including anterior segment optical coherence tomography (AS-OCT) for the detection of an occludable angle. For all 47 studies included in the review (including the 27 AS-OCT studies) the authors compared their accuracy to a gonioscopic reference standard. The published paper found 23 studies that evaluated AS-OCT to gonioscopy whereas in the Cochrane review by Jindal et al., they investigated 27 studies that evaluated AS-OCT compared to the reference standard of gonioscopy, therefore this that may affect the published paper's findings. Furthermore the published paper has not discussed how their meta-analysis, discussion and conclusions differs from the published Cochrane review by Jindal et al. In the current review it was reported that 'AS-OCT allows for earlier detection and provides a tool for screening where there is very little else available.' This statement is contrary to the findings of the Cochrane library [1] where the metaanalysis and comparisons of non-contact tests demonstrated that LACD had superior specificity to AS-OCT and similar sensitivity. Furthermore it is generally acknowledged that LACD is a test that can be performed without the need of additional equipment and where a conventional slit-lamp can be used therefore LACD is particularly applicable in settings where costs may be a barrier for implementation. The second incorrect statement is: 'Our review has been the first to perform a meta-analysis of data that assesses the accuracy of AS-OCT for detecting angle closure against gonioscopy as a reference standard. The authors would also like to confirm that Jindal et al. published the first systematic review to include a meta analysis of the accuracy of AS-OCT against a gonioscopic reference standard. Non-contact tests for identifying people at risk of primary angle closure glaucoma