key: cord-0027590-zjgc5tye authors: Safai Zadeh, Ehsan; Görg, Christian; Kuttkat, Phillip; Dietrich, Christoph Frank; Westhoff, Christina Carolin; Rodepeter, Fiona; Trenker, Corinna; Görg, Marvin; Kirschbaum, Andreas; Alhyari, Amjad title: The Value of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Perfusion Disturbances in Abdominal Wall Hernias Compared with Surgical and Histological Assessment date: 2022-02-01 journal: Diagnostics (Basel) DOI: 10.3390/diagnostics12020370 sha: 28e1ab07f5c5e6a4b224cb8593b17c862987140a doc_id: 27590 cord_uid: zjgc5tye Purpose: This study aimed to evaluate the value of contrast-enhanced ultrasound (CEUS) in the evaluation of perfusion disturbance in irreducible abdominal wall hernias (AWHs). Methods: From 2006 to 2018, 50 patients with an irreducible AWH were examined using B-mode ultrasound (B-US) and CEUS. The ultrasound findings were correlated with subsequent surgical and histological results. The presence of non-enhanced areas (NEAs) in hernia contents on CEUS and the presence of non-perfused areas (NPAs) on surgical and histological evaluation were analyzed retrospectively. Results: On CEUS, 13/50 hernia contents (26.0%) revealed NEAs during complete CEUS examination and 37/50 (74.0%) revealed no NEAs during CEUS examination. On surgical and histological evaluation, NPAs in hernia contents were identified in 11/13 cases (93.3%) with NEAs on CEUS. CEUS was found to have a sensitivity of 100.0%, a specificity of 94.9%, a positive predictive value of 84.6%, and a negative predictive value of 100.0% for the identification of perfusion disturbance in AWHs. Conclusions: The findings of this study demonstrate that using CEUS as an imaging method may be helpful for evaluating the perfusion of hernia contents in incarcerated AWHs. On CEUS, the presence of NEAs may suggest perfusion disturbance in hernia contents. Abdominal wall hernia (AWH) is a common disease. Its prevalence depends on age and is described in the literature to be 1.7% for all ages and 4.0% for people over 45 years old [1] [2] [3] . Furthermore, it is estimated that more than 20 million hernias are operated on worldwide each year [4] . Although surgical correction is elective in most patients, approximately 5.0-13.0% of patients require emergency surgery due to a strangulated AWH with blood flow disturbance in the hernia contents (omentum or bowel) [5] . Emergency cases are associated with high morbidity ranging from 19% to 30% (e.g., pulmonary and cardiac complications, anastomotic leakage and ileus, and wound infections) and high early mortality (within 30 days after an operation or before discharge from the hospital) ranging from 1.6% to 19.4% [6] . The most important prognostic factor in these patients is the time from the onset of symptoms to surgical therapy [7] . Therefore, the early detection of perfusion disturbance due to a strangulated AWH may be beneficial for identifying patients who require urgent surgery and could improve the outcome of these patients [7] . A widely used and proven imaging modality in clinical practice for the detection of perfusion disturbances is contrast-enhanced ultrasound (CEUS) [8] [9] [10] [11] [12] . The aim of this study was to determine the diagnostic value of CEUS in the detection or exclusion of perfusion disturbance in the hernia contents in irreducible AWH subsequently managed surgically. From February 2006 to April 2018, 75 patients with a clinical irreducible AWH were examined in a university ultrasound (US) center. All the patients were investigated and standardized using B-mode ultrasound (B-US) and CEUS by a German Society for Ultrasound in Medicine (DEGUM) Level III-qualified examiner (C.G., internal medicine) using CEUS [13] . The inclusion criteria for the retrospective analysis were (1) confirmation of the diagnosis by surgical intervention and (2) surgical evaluation and histopathological examination of the hernia contents regarding disturbed perfusion. In total, 50 patients were included in the study, and informed consent was obtained from each patient for the US examinations. This retrospective study was approved by the local ethics committee and conducted in accordance with the amended Helsinki Declaration on the ethical principles for medical research involving human subjects. The US examinations were carried out with an ACUSON SEQUOIA 512 GI US scanner (Siemens, Erlangen, Germany) and a 4C1 curved-array transducer. For the subsequent CEUS examination of hernia contents, a frequency of 1.5 MHz was used in contrast-specific mode. The CEUS investigations were performed according to the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines [8] . A bolus injection of 2.4 mL of SonoVue contrast medium (Bracco Imaging S.p.A., Milan, Italy) was administered via peripheral venous access, followed by 10 mL of 0.9% NaCl. The hernia contents were continuously examined for the first 30 s. Subsequently, several short examinations were performed at 30 s intervals up to 2 min, and the changes in the perfusion pattern were saved as images. The following data were retrospectively evaluated. The hernia contents were classified as omentum or bowel by B-US. Hernia contents with an echogenic mass and without detection of bowel loops were defined as an omental hernia, and the clear detection of bowel loops with mixed echogenicity due to a reverberation artifact of air in the bowel loops was defined as an intestinal hernia [14, 15] . The simultaneous presence of bowel and omentum was considered an intestinal hernia. The presence of non-enhanced areas (NEAs) in hernia contents ( Figure 1B ,C) was assessed during the CEUS examination [8, 10] . The US data were retrospectively analyzed by two independent, experienced investigators (E.S. and C.G.). In the event of discrepancies, the final decision was made by a third experienced investigator (A.A.). The investigators were blinded to the surgical and histopathologic results during the evaluation of the US data. Hernia contents were evaluated during surgical intervention and classified as omentum, bowel, or an empty sac. Macroscopic and microscopic confirmation or exclusion of non-perfused areas (NPAs) (necrosis, hemorrhage, and fibrosis) in hernia contents was conducted. All resected tissues were subjected to hematoxylin-eosin staining, and all tissue samples were evaluated microscopically by an experienced pathologist at the local Institute of Pathology. Sensitivity, specificity, and positive and negative predictive values were evaluated for pathological US findings. Cohen's kappa statistics were applied to measure interrater reliability, and a p-value of <0.05 was defined as significant. Of the 50 participants, 25 were male and 25 were female. The mean age of the patients was 62.3 years (with a range from 21 to 91 years). The clinical data of the patients are shown in Table 1 . Surgical correction was performed within 24 h after the CEUS examination in 21/50 patients (42.0%), within 7 days after the CEUS examination in 14/50 patients (28.0%), and >7 days after CEUS examination in 15/50 patients (30.0%). On B-US, the hernia contents were identified as omentum in 27/50 cases (54.0%) and as small bowel in 23/50 cases (46.0%). On CEUS, 13/50 hernia contents (26.0%) revealed NEAs during the complete CEUS examination (Figures 2-4) , whereas 37/50 hernia contents (74.0%) revealed no NEAs during the complete CEUS examination ( Figure 5 ). The agreement between the examiners for the US finding was good (Cohen's kappa = 0.79). Surgical correction was performed in all patients. Macroscopic evaluation during the surgical intervention and/or histological examination of the resected tissue showed the hernia contents to be omentum in 25/50 cases (50.0%) and bowel in 20/50 cases (40.0%). In 5/50 cases (10.0%), the hernia sac was empty. In 2/50 cases (4.0%), the hernia contents were demonstrated by the US to be bowel and in the surgical evaluation to be omentum ( Table 2 ). The hernia contents were consistent with the US findings in 44/50 cases (88.0%) (Cohen's kappa = 0.78, 'good'). Table 2 . B-mode ultrasound data of abdominal hernia and its correlation with surgical/histopathological evaluation in terms of hernia contents. In 32/50 cases (64.0%), no resection of the hernia contents was performed. In the remaining 18/50 cases (36.0%), a resection of the omentum (13/50; 26.0%) and of the bowel (5/50; 10.0%) was performed. On histological examination of the resected tissue samples, NPAs were absent in 7/18 cases (38.9%). NPAs (necrosis, hemorrhage, and fibrosis) were present in 11/18 cases (61.1%), including bowel infarction (4/11), omental infarction (3/11), and omental fibrosis (4/11). With regard to the correlation of NEAs to NPAs, of the 13 patients with NEAs on CEUS, NPAs were detected on histopathologic examination of 11/13 cases (93.3%) ( Table 3 ). In the remaining two patients with NEAs on CEUS with omental hernias, emergency surgical correction was immediately performed (<6 h after the CEUS examination). CEUS was found to have a sensitivity of 100.0%, a specificity of 94.9%, a positive predictive value of 84.6%, and a negative predictive value of 100.0% for the identification of perfusion disturbance in the AWH contents. The World Society of Emergency Surgery guidelines recommend contrast-enhanced computed tomography (CT) as the imaging modality of choice for diagnosing strangulated AWHs [16] . In addition to contrast-enhanced CT, B-US is widely used for the evaluation of strangulated AWHs as the initial imaging modality and the expanded form of physical examination [17, 18] . However, to the best of our knowledge, no data are available regarding the diagnostic performance of CEUS as an additional imaging modality in the diagnosis of perfusion disturbance in strangulated AWHs. In a standardized and surgically controlled study, we investigated the diagnostic accuracy of B-US for the evaluation of the hernia contents and the diagnostic accuracy of CEUS in the detection of perfusion disturbance in the hernia contents of 50 patients with an irreducible AWH. Regarding the hernia contents, the US findings agreed with the surgical evaluations in 44/50 cases (88.0%). The difference in the remaining six cases could be due to the spontaneous reduction in hernia contents. It has been described previously in the literature that an incarcerated hernia can reduce spontaneously or during the administration of muscle relaxants during induction of anesthesia [19, 20] . Regarding perfusion disturbance in the hernia contents, CEUS revealed a sensitivity of 100.0%, a specificity of 94.9%, a positive predictive value of 84.6%, and a negative predictive value of 100.0% for the identification of histologically proven perfusion disturbance of the AWH contents. In the two patients with NEAs on CEUS and no evidence of perfusion disturbance on histological examination, emergency surgical corrections were performed within 6 h after the CEUS examination. Therefore, it could be speculated that tissue damage would not have occurred in these two patients due to the short time between incarceration and surgical intervention with the successful restoration of reperfusion. The sensitivity and specificity of CEUS in the present study compared with the findings of previously performed color Doppler sonography and contrast-enhanced CT studies are summarized in Table 4 . The reason for the higher sensitivity of CEUS compared to a contrast-enhanced CT may be the strictly intravascular characteristics of the contrast medium of CEUS [22] ; therefore, the non-perfused areas show an absence of enhancement during the complete CEUS examination, distinguished from perfused tissue. However, omental hernias were included in the present study. Notably, in a study by Jancelewicz et al., only the diagnostic performance of CECT in detecting a strangulated small bowel was investigated [21] . Therefore, a comparison between both studies is limited. The high sensitivity and specificity of CEUS in the diagnosis of perfusion disturbance in incarcerated hernias demonstrate that CEUS should be considered a useful and costeffective method without a radiation-exposing imaging modality. The findings of this study are in accordance with previous studies that showed that CEUS has a high diagnostic performance in the detection of perfusion disturbance [8, 9, [23] [24] [25] [26] [27] [28] [29] . Notably, the cause of NEAs in CEUS was an omental tissue fibrosis in four cases. This finding demonstrates that, in omental hernias, omental tissue fibrosis should be considered a differential diagnosis in addition to an acute perfusion disturbance. The fibrosis could be the result of recurrent incarcerations with chronic impaired perfusion and hypoxia [30] . There were limitations to this study: The sample size was relatively small. Furthermore, this study was limited by the retrospective data collection and, generally, by the well-known high interobserver variability of the US. Moreover, blinding of the investigators to the study group and blind interpretation of the US data by the US examiners were not possible. The study was performed on patients who were referred to the Interdisciplinary Centre of Ultrasound Diagnostics for the investigation of an irreducible AWH and were examined and standardized by a single DEGUM Level III-qualified examiner. Therefore, it was not possible to exclude selection bias. Another limitation of our study is the semiquantitative analysis of the US data, which probably allows more room for interpretation than a quantitative measurement, although interrater observer variability for the US findings was performed with good agreement. The findings of this study demonstrate that the presence of NEAs on CEUS may be suggestive of perfusion disturbance. Furthermore, the CEUS pattern of omental infarction was described as a rare disease, and it was shown that omental fibrosis should be considered as a differential diagnosis in addition to acute infarction in the event of the presence of NEAs in the omentum. In summary, the findings of this study demonstrate that using CEUS as an imaging method may be helpful for evaluating the perfusion of hernia contents in incarcerated AWHs. The potential of CEUS in the clinical diagnostic algorithm of irreducible AWHs should be evaluated in a prospective randomized study. Author Contributions: E.S.Z., A.A. and C.G. designed the study and were guarantors of the paper. E.S.Z. evaluated and interpreted the data and wrote the manuscript based on the support and comments of all other authors. All authors participated in the data preparation, literature search, and interpretation of results. E.S.Z., C.G., P.K., C.C.W., F.R., M.G., C.T., C.F.D., A.K. and A.A. reviewed the manuscript. All authors have read and agreed to the published version of the manuscript. Informed Consent Statement: Informed consent was obtained from all subjects involved in the study for ultrasound examinations. The data presented in this study are available from the corresponding author upon request. Trends in Emergent Hernia Repair in the United States Prevalence and risk factors for abdominal wall hernia in the general Russian population risk factors and character of abdominal hernia in Arar City, Northern Saudi Arabia in 2017 Frequency of abdominal wall hernias: Is classical teaching out of date? Emergency hernia surgery at a high-volume tertiary centre: A 3-year experience Emergency surgery of the abdominal wall hernias: Risk factors that increase morbidity and mortality-A single-center experience Optimal timeline for emergency surgery in patients with strangulated groin hernias The EFSUMB Guidelines and Recommendations for the Clinical Practice of Contrast-Enhanced Ultrasound (CEUS) in Non-Hepatic Applications: Update 2017 (Long Version) Clinical Awareness and Acceptance of Sonographically Diagnosed Epiploic Appendagitis (EA): A Retrospective Analysis of EA in a Contrast-enhanced ultrasound of epiploic appendagitis Spontaneous and Traumatic Splenic Rupture: Retrospective Clinical, B-Mode and CEUS Analysis in 62 Patients Contrast enhanced ultrasonography (CEUS) to detect abdominal microcirculatory disorders in severe cases of COVID-19 infection: First experience Diagnostische Wertigkeit einer internistischen Referenzsonographie (DEGUM-Stufe 3) Groin abnormalities: Ultrasonographic and clinical findings B-mode ultrasound and contrast-enhanced ultrasound (CEUS) of histological confirmed omental lesions: Retrospective analysis of n = 44 patients WSES guidelines for emergency repair of complicated abdominal wall hernias Diagnosis of a Strangulated Laparoscopic Incisional Hernia with Point-of-Care Ultrasonography Abdominal Wall Hernias Beware of spontaneous reduction "en masse" of inguinal hernia Hernioscopy: A useful technique for the evaluation of incarcerated hernias that retract under anaesthesia Predicting strangulated small bowel obstruction: An old problem revisited Contrast-enhanced ultrasound perfusion imaging of organs. Der Radiol The EFSUMB Guidelines and Recommendations on the Clinical Practice of Contrast Enhanced Ultrasound (CEUS): Update 2011 on non-hepatic applications Acute segmental testicular infarction at contrast-enhanced ultrasound: Early features and changes during follow-up Contrast-enhanced ultrasound for the evaluation of acute renal infarction Single-center study: The diagnostic performance of contrast-enhanced ultrasound (CEUS) for assessing focal splenic lesions compared to CT and MRI Contrast-Enhanced Ultrasound in Patients With COVID-19: Pneumonia, Acute Respiratory Distress Syndrome, or Something Else? The role of contrast enhanced ultrasound in the differential diagnosis of segmental testicular infarction Contrast-enhanced ultrasound of liver lesions related to arterial thrombosis in adult liver transplantation Hypoxia promotes fibrogenesis in vivo via HIF-1 stimulation of epithelial-to-mesenchymal transition Acknowledgments: We thank Anneliese Pohl Foundation (Anneliese Pohl Stiftung) for supporting this study. Open Access funding provided by the Open Access Publication Funds of Philipps-Universität Marburg.