key: cord-0026466-fpkwlsxt authors: Lee, Solam; Chu, Yuseong; Ryu, Jiseung; Park, Young Jun; Yang, Sejung; Koh, Sang Baek title: Artificial Intelligence for Detection of Cardiovascular-Related Diseases from Wearable Devices: A Systematic Review and Meta-Analysis date: 2022-01-06 journal: Yonsei Med J DOI: 10.3349/ymj.2022.63.s93 sha: 56ba742395c327f99d154e985aee45dd393c7dba doc_id: 26466 cord_uid: fpkwlsxt PURPOSE: Several artificial intelligence (AI) models for the detection and prediction of cardiovascular-related diseases, including arrhythmias, diabetes, and sleep apnea, have been reported. This systematic review and meta-analysis aimed to identify AI models developed for or applicable to wearable and mobile devices for diverse cardiovascular-related diseases. MATERIALS AND METHODS: The searched databases included Medline, Embase, and Cochrane Library. For AI models for atrial fibrillation (AF) detection, a meta-analysis of diagnostic accuracy was performed to summarize sensitivity and specificity. RESULTS: A total of 102 studies were included in the qualitative review. There were AI models for the detection of arrythmia (n=62), followed by sleep apnea (n=11), peripheral vascular diseases (n=6), diabetes mellitus (n=5), hyper/hypotension (n=5), valvular heart disease (n=4), heart failure (n=3), myocardial infarction and cardiac arrest (n=2), and others (n=4). For quantitative analysis of 26 studies reporting AI models for AF detection, meta-analyzed sensitivity was 94.80% and specificity was 96.96%. Deep neural networks showed superior performance [meta-analyzed area under receiver operating characteristics curve (AUROC) of 0.981] compared to conventional machine learning algorithms (meta-analyzed AUROC of 0.961). However, AI models tested with proprietary dataset (meta-analyzed AUROC of 0.972) or data acquired from wearable devices (meta-analyzed AUROC of 0.977) showed inferior performance than those with public dataset (meta-analyzed AUROC of 0.986) or data from in-hospital devices (meta-analyzed AUROC of 0.983). CONCLUSION: This review found that AI models for diverse cardiovascular-related diseases are being developed, and that they are gradually developing into a form that is suitable for wearable and mobile devices. Digital healthcare is a field that deals with personal health and medical information, devices, systems, and platforms, and encompasses the convergence of comprehensive medical services. 1 Although digital healthcare is an umbrella term used for various purposes, in essence, it refers to offering healthcare services for the prevention, diagnosis, treatment, and follow-up management of diseases regardless of time and location by connecting healthcare with information and communication technology. Traditionally, the field of healthcare has been centered on healthcare institutions and physicians, and the medical infor-mation they generated was exclusively handled by healthcare workers within the hospital. However, over time, the focus shifted to the prediction and prevention of chronic diseases, rather than treatment-oriented medicine, with the growing interest in healthcare outside the hospital. 2 Against this background, digital healthcare is also developing at a rapid pace due to the remarkable advances in computing power and technologies related to data acquisition and analysis. For instance, the development of various sensors, communication networks, and portable and wearable devices has enabled data acquisition during the day-to-day life of a patient. 3 Based on the acquired data as such, the development of algorithms for diagnosing or predicting specific diseases outside the hospital, so-called medical artificial intelligence (AI), has emerged as a major area of research. Cardiovascular disease is the most common cause of death in the United States, 4 and it incurs annual medical costs of up to $363 billion. 5 Since most cardiovascular diseases follow a chronic course, lifestyle modifications and the periodic monitoring of diseases are very important even after acute treatment in hospital. Therefore, it is difficult to cope with the burden and death of cardiovascular disease by treatment in hospital alone. Meanwhile, several AI models for the detection and prediction of arrhythmias, diabetes, and sleep apnea using biosignals, such as those used for electrocardiogram (ECG) or photoplethysmography (PPG), have been reported. A systematic literature review revealed that deep learning models for analyzing ECG showed better performance compared to existing methods, such as the hardware or rule-based algorithms used for the detection or prediction of cardiovascular disease. 6 However, it is difficult to apply any of them to a wearable device. A conventional supine 12-lead ECG or arterial pressure waveform, for instance, requires complicated or invasive procedures. We postulated that a separate review of AI algorithms which could be applied to wearable devices was necessary to evaluate the applicability of AI for cardiovascular-related diseases in digital healthcare settings. This systematic literature review and meta-analysis aimed to identify the AI models developed for or applicable to wearable devices for cardiovascular-related diseases. This systematic review and meta-analysis was performed in accordance with the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020. 7 The searched databases included Medline, Embase, and Cochrane Library. The purpose of the search was to identify the studies related to medical AI used to detect or predict cardiovascular-related disease, which have been developed or applicable to portable and wearable devices. A wide range of key-words were set by referring to previous related reviews 8, 9 to include the AI models for various cardiovascular-related diseases (cardi*, heart*, coronary*, angina*, ventric*, myocard*, pericard*, isch(a)em*, arrhythm*, atrial fibrillat*, tachycardi*, endocardi*, stroke, cerebro*, hypertensi*, blood pressure, hyperlipid*, hyperchole*, hyperlipo*, hypertrigly*, arterio*, arthero*, metabolic, deep learning, neural network, artificial intelligence, smart, wearable, portable, 1-lead, single lead, photoplethysmog*, and PPG). The search was performed on September 5, 2021, by one author (S.L), and all publications searched from January 1, 1970 to the present were searched without any limitation on the publication date. The abstracts and titles of the retrieved studies were first screened by two main reviewers (S.L and Y.C). The criteria for eligible studies were as follows: 1) studies whose main tasks related to the detection or prediction of cardiovascular-related disease; 2) studies that developed AI models by utilizing either deep learning or conventional machine learning algorithms; 3) studies that developed AI models for smartphones or using data acquired from mobile and wearable devices; and 4) studies that used biosignals that are considered relatively easy to obtain outside of healthcare institutions, such as 1-lead or 2-lead ECG and PPG, even if those studies did not directly present the keywords associated with wearable device. The exclusion criteria were as follows: 1) studies that simply measured or estimated cardiovascular parameters (e.g., heart rate and blood pressure), regardless of disease status; 2) studies that used invasive signals (e.g., arterial pressure waveform); 3) studies that reported only the models with biosignals that are difficult to apply to wearable devices, such as conventional supine 12-lead ECG; and 4) studies that did not report the quantitative performance of the model. All studies whose eligibility could not be determined based on the abstract and title alone were included in the full-text evaluation. Studies written in languages other than English or Korean were excluded due to the language proficiency of the authors. Studies with only abstracts in which details on the study settings or design, the nature of the data used were unknown, and the details of the model were unknown were also excluded. In the case of disagreement between the two main reviewers, eligibility was finally decided through discussion with two additional reviewers (J.S.R and S.Y). We extracted important variables using data extraction sheets from the final selected studies. The data sheets were defined prior to conducting the literature searches and study selection. The items extracted from each study included the publication year, author, target disease, task, data availability (public or proprietary), data source (in-hospital device or wearable device), input data domain (ECG, PPG, combined or others), algorithm type (conventional machine learning or deep neural network), and model performance metrics. So far, there has been no optimal assessment tool that can evaluate the applicability and risk of bias for AI studies. Therefore, we evaluated the risk of bias of individual studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUA-DAS-2) tool. 10 However, since the validity of using the scale has not been verified for AI studies, it was not used to determine whether to include or exclude a particular study. We intended to synthesize the performance of AI models that could be mounted on wearable devices or mobile devices, and that could be used to predict various cardiovascular-related diseases and present them as summary statistics. However, according to our pilot study, most of the identified models were developed for the detection of atrial fibrillation (AF). Therefore, the quantitative meta-analysis was limited to studies on AF. For those studies, the number of true positives, false positives, true negatives, and false negatives were extracted. If those parameters were not directly presented, they were estimated from the number of subjects (AF and non-AF) and the performance metrics, such as sensitivity and specificity. In order to resolve heterogeneity among studies in the meta-analysis, subgroup analysis was performed according to the algorithm type (conventional machine learning vs. deep neural network), data availability (public vs. proprietary), and data source (in-hospital device vs. wearable device). Only qualitative analysis was performed for studies on diseases other than AF. The number of true positives, false positives, true negatives, and false negatives were used to calculate meta-analyzed sensitivity and specificity. As high heterogeneity between studies was suspected, a random-effects model was used for synthesis. Forest plots for sensitivity and specificity for AF detection was created by using R package meta. 11 Hierarchical summary receiver operating characteristics curves and 95% confidence interval (CI) were estimated by the Reitsma bivariate model 12 using R package mada. 13 All statistical analyses were performed by using R version 4.1.0 (R Statistical Computing). The PRISMA 2020 flow diagram is shown in Fig. 1 . After a full text review, 102 studies in total were included in the qualitative review. Table 1 presents the summary statistics for the included studies. line) shows the description and findings of the individual studies. Supplementary Fig. 1 (only online) shows the quality assessment for the included studies using the QUADAS-2 tool. As described above, as the validity of the tool used to evaluate the quality of research for development and validation of AI models has not yet been verified, all individual studies were included in the final analysis regardless of the quality assessment results. In 68 studies, deep learning methods, such as neural networks, were used alone or in combination with other machine learning methods (Table 1 ). Unlike conventional methods that extracted several handcrafted features from ECG or PPG and used them for training and validation of algorithms for disease prediction, methods that used deep learning tended to utilize the signal itself as an input (Fig. 2 ). For input domain, 1-lead and 2-lead ECG were the most commonly used biosignals, followed by PPG. They were often used as a single input source, but some studies used multimodal data. 23, 28, 98 A total of 59 studies used an open dataset, most of which were related to the detection of arrhythmias or sleep apnea. Supplementary Table 2 (only online) summarizes the representative public datasets containing 1-lead or 2-lead ECG or PPG data. However, the models for diabetes and other diseases mostly used proprietary datasets that were newly collected or constructed for the study. There were 47 studies that utilized data collected through wearable devices, such as smart watches. The studies related to arrhythmias accounted for the largest proportion, at 62 studies (Supplementary Table 1 , only online). Most studies had AF detection as the main task. The arrhythmias other than AF, such as premature ventricular contraction, were often grouped and treated as "non-AF" or "other rhythms. " A large number of models have been reported based on the rich public dataset, which allowed performance comparisons between the studies. Although many studies have utilized public datasets, such as the MIT-BIH database alone, there were also studies that performed external validation by constructing a proprietary dataset with multi-institutional data. 17, 23, 26, 27 In total, 26 studies included AF as a detection target, and thus were included in the quantitative meta-analysis. The diagnostic accuracy of AF detection models are presented in Figs. 3 and 4A. The results overall show very high performance with a meta-analyzed sensitivity of 94.80% (95% CI, 91.94%-96.68%) and specificity of 96.96% (95% CI, 94.99%-98.17%). In the subgroup analysis performed to resolve the heterogeneity between studies, however, there was a significant difference in the model performance between studies ( Fig. 4B-D) . The models developed with deep neural network alone or combined with other algorithms (AUROC of 0.981) showed a superior performance compared to the models developed with conventional machine learning alone (AUROC of 0.961). In contrast, the models tested on the proprietary data (AUROC of 0.972) showed an inferior performance compared to the models tested on the public data (AUROC of 0.986). In addition, the model tested on the data acquired from wearable devices (AUROC of 0.977) showed an inferior performance than the models tested on the data acquired from in-hospital devices (AUROC of 0.983). With the advent of deep neural networks, the competition for predictive performance has virtually reached saturation, and the development of a lightweight model that can be mounted on a wearable device and operated in real time has recently become a major topic of research. 18, 27 There have been studies to determine a critical point that does not compromise the diagnostic accuracy while reducing the data size through compression of the ECG signal itself, in addition to reducing the weight of the model. 32, 38, 43 Meanwhile, research using the ECG data collected through a ring-type or patch-type device, rather than data collected in a hospital, has been reported. 40, 44 These studies have also shown satisfactory performance in general, but reported slightly lower performance for detecting arrhythmias compared to the models trained with resting ECG-based data obtained in the hospital. One study, in particular, reported difficulty for an algorithm trained on resting ECG data to show proper prediction perfor- arrest, 111 and other conditions, including cardiac amyloidosis and anemia (Table 2) . [112] [113] [114] [115] The most common study following arrhythmia was the detection of sleep apnea. Sleep apnea itself is not a cardiovascular disease, but obstructive sleep apnea is a major detection target for prediction models for cardiovascular-related disease that use wearable devices, as it is associated with or increases the risk of major cardiovascular diseases. The public dataset PhysioNet Apnea-ECG 116 has been used in numerous studies. There have been several studies that used raw ECG with deep learning algorithms, but machine learning models using hand-mance when applied to ambulatory ECG data. 64 In addition, a model that could detect AF in a large number of patients using a video of the facial region rather than ECG monitoring was reported, confirming that diverse types of input data could be utilized. 36 There were few studies on the screening and detection of diseases such as sleep apnea, [76] [77] [78] [79] [80] [81] [82] [83] [84] [85] [86] peripheral vascular diseases, [87] [88] [89] [90] [91] [92] diabetes, [93] [94] [95] [96] [97] hyper/hypotensive disease, 98-102 valvular disease, 103-106 heart failure, 107-109 myocardial infarction, 110 cardiac crafted features, such as heart rate variability, have also been reported. In addition to ECG, there have also been studies that use PPG, many of which were studies that used proprietary datasets. There was a study to predict the apnea-associated index using wrist-worn reflective PPG obtained directly using a wearable device. 79 This particular study investigated the changes in model performance due to limbic movement, and reported that false positive detection had an adverse effect on the specificity and positive predictive value of the model. These studies mainly used proprietary datasets, as there were very few public datasets available. As expected, they showed very heterogeneous performance, depending on the task. For instance, the models showed very high predictive power for valvular diseases, such as aortic stenosis, which is known to accompany some changes in the ECG. However, the models did not show an equally high performance for the detection of diabetes or anemia that were not accompanied by substantial changes in the ECG. In a study that developed an AI model for heart failure, the algorithm was tested on several populations with a varying prevalence of heart failure, confirming a very Herraiz, et al. 26 Wu, et al. 45 Chen, et al. 28 Marinucci, et al. 30 Hernandez, et al. 58 Shi, et al. 15 Zhang, et al. 32 Hannun, et al. 47 Lai, et al. 49 Liang, et al. 33 Ghosh, et al. 34 Kwon, et al. 44 Xiong, et al. 61 Yan, et al. 36 Lee, et al. 98 Torres-Soto and Ashley 39 Fan, et al. 62 Hickey, et al. 75 Lai, et al. 40 Zhang, et al. 20 Plesinger, et al. 63 Tison, et al. 64 Jacobsen, et al. 41 Nguyen, et al. 22 Gahungu, et al. 25 Yan, et al. 66 large difference in the accuracy of the algorithm from 82.51% to 99.22%, depending on the prevalence of heart failure in the study population. 108 For diseases other than arrhythmia, it was difficult to compare the performance of models due to the small number of studies for each disease, as well as the use of data from heterogeneous settings. Considering the low availability of public data and the characteristics of studies with individual datasets, external validation was rarely performed. This systematic review and meta-analysis summarized the AI models that were developed for or that are potentially useful for wearable devices, and that could be used to detect or predict cardiovascular-related diseases. In addition to the models for arrhythmia detection, including AF, studies have reported on models to predict various cardiovascular-related diseases such as sleep apnea, diabetes, valvular disease, and anemia. Fig. 2 summarizes the development and application of an AI model for the detection and prediction of cardiovascular-related diseases. The first step is data collection. The most commonly used biosignal for monitoring using a wearable device is the 1-lead or 2-lead ECG signal, followed by PPG. Owing to a large database, such as the MIT-BIH arrhythmia database, 122, 123 various detection models for arrhythmias, including AF, have been reported. As these were hospital-based data, there was a limit to using the data in implementing an algorithm for wearable devices. Fortunately, the availability of biosignals that were collected using mobile devices has increased, as databases such as the PhysioNet Computing in Cardiology Challenge 117 have been made public. However, there is a clear need for ambulatory biosignals, since the performance of an algorithm devel- oped from the data of a resting setting is quite poor in an ambulatory setting. 64 Recently, in addition to Holter monitoring, which has been traditionally used, the use of patch-type, watchtype, ring-type, and clothing-type monitoring systems have been approved by the FDA. 138 Accordingly, the availability of ambulatory biosignals is expected to increase significantly in the future. One thing to note in relation to the data is the difference in systematic performance between the models that use public datasets, proprietary datasets, data acquired from in-hospital devices, and data acquired from wearable devices. Data characteristics may vary significantly depending on the methods (resting vs. ambulatory) and settings (intensive care unit, inpatient, outpatient, and general population) of data acquisition. For example, the prevalence of cardiovascular diseases varies greatly depending on the population, and the class imbalance between normal data and disease data may have a significant impact on the model performance. 108 Therefore, it is very important in model development to use the collected from a population group that has characteristics similar to the target group to which the developed AI model will be applied. In order to develop a more universal model from the perspective of digital healthcare, it is preferable to use data collected from large general populations rather than data collected from hospitals. The collected data are transformed into a form more suitable for model learning through preprocessing, such as denoising or normalization. For example, the length of the input signal could be changed or converted to an average signal, depending on the type or design of the AI model. Various machine learning methods have been used to predict cardiovascular disease using handmade features such as heart rate variability, R-R interval, and QRS amplitude extracted from ECG or PPG as general input values. However, the popularization of deep neural networks has enabled raw signals themselves to be used as input data. Since biosignal data has a time-series characteristic and is not limited in the length of an input signal, recurrent neural network (RNN) or long short-term memory is logically the most preferred model. However, there have been a considerable number of models that used convolutional neural network (CNN) alone or CNN combined with RNN-based algorithms. In addition to signals, facial imaging videos have been used in a model for detecting arrhythmias. 36 Those developed with deep neural networks generally perform better than traditional models, suggesting the possibility that AI can extract features from imaging as well as signal data that can be used for predicting disease states that humans cannot visualize. Although current studies have often used a single biosignal as an analysis domain, it would be possible to develop a multimodal model that utilizes various signals, imaging data, and other clinical information together. Nevertheless, the most significant problem with deep learning is that it has a black box-like characteristic that makes understanding its operation and judgment principle difficult. De-spite the high accuracy of deep learning models, the decisions cannot be accepted by healthcare workers without proper interpretation. While a small number of studies have adopted a strategy that uses salient maps to improve interpretability, 98, 113 such attempts are still difficult to find compared to the models in the field of medical imaging. Extracting interpretable handcrafted features from clinical information or biosignals that are familiar to human experts and using them together in deep learning models could be a feasible alternative to improving the interpretability of AI. Unlike medical imaging, AI models for cardiovascular-related disease are preferred to be used with wearable and portable devices carried by individuals in their day-to-day lives. It is difficult to operate a large-scale model on portable devices due to hardware limitations. For the analysis of lifelogs collected in real time, the operating speed is also a major consideration. Therefore, it is essential to develop a lightweight and fast model, even if there is a slight loss in performance. 18, 27, 32, 38, 43 Second, the algorithm is operated in an environment that is not wellcontrolled, unlike a hospital environment. As mentioned earlier, a model that is developed using resting biosignals as a source rarely works well for ambulatory biosignals. 64 In addition, even resting ECG signals may be more prone to artifacts or noise if they are acquired in daily life. If too many false positive alarms for these abnormal signals occur, the user may prefer to stop using the wearable device. Therefore, proper data preprocessing and thresholding are required to detect a life-threatening condition without tiring the user. Wearable device-enabled detection of cardiovascular-related diseases are likely to become more common as healthcare technology expands. 139 It is estimated that more than 50 million people in the United States use wearable device to record their daily activities. 140 These lifelogs could lead to the early detection of diverse cardiovascular-related diseases and potentially life-threatening conditions. However, although patient-activated daily monitoring has the potential benefit to improve the detection of subclinical or occult diseases, there are limitations of their widespread use. For example, poor signal quality and false alarms can lead to inappropriate interpretation, resulting in unnecessary medical referrals and testing. 141 It is essential to understand the limitations of consumer-based technologies to avoid improper dependence on the diagnosis and treatment of cardiovascular diseases. 142 Even while these devices may help diagnose cardiovascular-related diseases, it remains to be seen how they can be optimally incorporated in current healthcare practices to improve patient outcomes. 139 One limitation of this systematic review and meta-analysis lies in the high heterogeneity of the studies included in the analysis. For instance, some studies used ECG data obtained from an intensive care unit, whereas some studies directly utilized data obtained with a smart watch. Although a subgroup analysis was performed to resolve the heterogeneity, nevertheless, inappropriate statistical estimates may have been produced in the process of quantitatively synthesizing studies that were conducted with data that were collected using different modalities from different population groups. In addition, for diseases and tasks other than AF, meta-analysis could not be performed, as there were too few studies to be quantitatively synthesized. In conclusion, this systematic review and meta-analysis revealed that AI models for the diagnosis and prediction of various cardiovascular-related diseases as well as arrhythmias are being developed, and that they are gradually developing into a form that is suitable for wearable and mobile devices. Numerous studies have demonstrated that the deep learning algorithm shows very high performance compared to the existing analysis methods that use human visualization or the extraction of handmade features for biosignals, such as ECG or PPG signals. However, there must still be sufficient consideration of various aspects, such as the data acquisition process, characteristics of the acquired data, characteristics of the population to which the algorithm is applied, weight reduction of the algorithm, working principle, and interpretability of the model, to develop a practical medical AI model that can be used in the real world. The outlook of digital health for cardiovascular medicine: challenges but also extraordinary opportunities Digital health is a cultural transformation of traditional healthcare Smart wearables for cardiac monitoring-real-world use beyond atrial fibrillation Underlying Cause of Death Heart disease and stroke statistics-2021 update: a report from the American Heart Association Deep learning for cardiovascular medicine: a practical primer The PRISMA 2020 statement: an updated guideline for reporting systematic reviews Creatine and creatine analogues in hypertension and cardiovascular disease Statins for the primary prevention of cardiovascular disease QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies Zwinderman AH. Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews Package 'mada' A multiview feature fusion model for heartbeat classification Automated atrial fibrillation detection based on feature fusion using discriminant canonical correlation analysis Automatic premature ventricular contraction detection using deep metric learning and KNN. Biosensors (Basel) 2021 Explainable artificial intelligence to detect atrial fibrillation using electrocardiogram KecNet: a light neural network for arrhythmia classification based on knowledge reinforcement Learning explainable time-morphology patterns for automatic arrhythmia classification from short single-lead ECGs Over-fitting suppression training strategies for deep learning-based atrial fibrillation detection Premature beats detection based on a novel convolutional neural network Stacking segment-based CNN with SVM for recognition of atrial fibrillation from single-lead ECG recordings TOP-Net prediction model using bidirectional long short-term memory and medical-grade wearable multisensor system for tachycardia onset: algorithm development study Toward real-time and efficient cardiovascular monitoring for COVID-19 patients by 5G-enabled wearable medical devices: a deep learning approach Transfer learning artificial intelligence for automated detection of atrial fibrillation in patients undergoing evaluation for suspected obstructive sleep apnoea: a feasibility study A deep learning approach for featureless robust quality assessment of intermittent atrial fibrillation recordings from portable and wearable devices A lightweight deep learning model for fast electrocardiographic beats classification with a wearable cardiac monitor: development and validation study A new smart wristband equipped with an artificial intelligence algorithm to detect atrial fibrillation A novel approach for atrial fibrillation signal identification based on temporal attention mechanism Artificial neural network for atrial fibrillation identification in portable devices Atrial fibrillation detection from raw photoplethysmography waveforms: a deep learning application Automatic screening method for atrial fibrillation based on lossy compression of the electrocardiogram signal Deep learning algorithm classifies heartbeat events based on electrocardiogram signals Detection of atrial fibrillation from single lead ECG signal using multirate cosine filter bank and deep neural network Heartbeat classification using deep residual convolutional neural network from 2-lead electrocardiogram High-throughput, contact-free detection of atrial fibrillation from video with deep learning Interpreting deep neural networks for singlelead ECG arrhythmia classification Multi-label arrhythmia classification from fixed-length compressed ECG segments in real-time wearable ECG monitoring Multi-task deep learning for cardiac rhythm detection in wearable devices Non-standardized patchbased ECG lead together with deep learning based algorithm for automatic screening of atrial fibrillation Reliable detection of atrial fibrillation with a medical wearable during inpatient conditions Robust classification of cardiac arrhythmia using a deep neural network Transfer learning for detection of atrial fibrillation in deterministic compressive sensed ECG Diagnostic performance of a wearable ring-type device with deep learning analysis of photoplethysmography for detecting atrial fibrillation (Abstract) A deep learning method to detect atrial fibrillation based on continuous wavelet transform A novel ring-type werable device equipped with deep learning algorithm using photoplesthymographic signals for detecting atrial fibrillation (Abstract) Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network Combining deep neural networks and engineered features for cardiac arrhythmia detection from ECG recordings Bin Heyat MB. Convolutional neural network based detection of atrial fibrillation combing R-R intervals and F-wave frequency spectrum Deep learning approaches to detect atrial fibrillation using photoplethysmographic signals: algorithms development study ECG classification algorithm based on STDP and R-STDP neural networks for real-time monitoring on ultra low-power personal wearable devices Energy-efficient intelligent ECG monitoring for wearable devices Smartwatch performance for the detection and quantification of atrial fibrillation A low-complexity algorithm for detection of atrial fibrillation using an ECG A novel application of deep learning for single-lead ECG classification A robust deep convolutional neural network for the classification of abnormal cardiac rhythm using single lead electrocardiograms of variable length Abductive reasoning as a basis to reproduce expert criteria in ECG atrial fibrillation identification Atrial fibrillation detection in short single lead ECG recordings using wavelet transform and artificial neural networks Densely connected convolutional networks for detection of atrial fibrillation from short single-lead ECG recordings Detection of atrial fibrillation from RR intervals and PQRST morphology using a neural network ensemble ECG signal classification for the detection of cardiac arrhythmias using a convolutional recurrent neural network Multiscaled fusion of deep convolutional neural networks for screening atrial fibrillation from single lead short ECG recordings Parallel use of a convolutional neural network and bagged tree ensemble for the classification of Holter ECG Passive detection of atrial fibrillation using a commercially available smartwatch Premature ventricular contraction detection from ambulatory ECG using recurrent neural networks Validation of a deep convolutional network for detecting atrial fibrillation with a wrist-worn wearable device (Abstract) AF classification from a short single lead ECG recording: the Physi-oNet/computing in cardiology challenge 2017 Real-time patient-specific ECG classification by 1-D convolutional neural networks Automatic diagnosis of premature ventricular contraction based on Lyapunov exponents and LVQ neural network Photoplethysmographybased method for automatic detection of premature ventricular contractions Arrhythmia identification with twolead electrocardiograms using artificial neural networks and support vector machines for a portable ECG monitor system A wearable smartphone-based platform for real-time cardiovascular disease detection via electrocardiogram processing Predicting cardiovascular disease from real-time electrocardiographic monitoring: an adaptive machine learning approach on a cell phone Real-time classification of ECGs on a PDA Non-episode-dependent assessment of paroxysmal atrial fibrillation through measurement of RR interval dynamics and atrial premature contractions FASSNet: fast apnea syndrome screening neural network based on single-lead electrocardiogram for wearable devices A sleep apnea detection system based on a one-dimensional deep convolution neural network model using single-lead electrocardiogram Screening of sleep apnea based on heart rate variability and long short-term memory Wearable monitoring of sleep-disordered breathing: estimation of the apnea-hypopnea index using wrist-worn reflective photoplethysmography Detection of sleep apnea from single-lead ECG signal using a time window artificial neural network In obstructive sleep apnea patients, automatic determination of respiratory arrests by photoplethysmography signal and heart rate variability. Australas Sleep apnea detection from a single-lead ECG signal with automatic feature-extraction through a modified LeNet-5 convolutional neural network Apnea recognition in wearable device using the intensive evaluation of the ECG power spectral density Automated detection of obstructive sleep apnea events from a single-lead electrocardiogram using a convolutional neural network An algorithm for sleep apnea detection from single-lead ECG using Hermite basis functions Automatic detection and quantification of sleep apnea using heart rate variability Deep learning-based photoplethysmography classification for peripheral arterial disease detection: a proof-of-concept study Prediction of ankle brachial index with photoplethysmography using convolutional long short term memory Prediction of vascular aging based on smartphone acquired PPG signals Predicting arterial stiffness from the digital volume pulse waveform Comparison of three arterial pulse waveform classification techniques Development of a neural network screening aid for diagnosing lower limb peripheral vascular toelectric plethysmography pulse waveforms Early detection of prediabetes and T2DM using wearable sensors and internet-of-things-based monitoring applications A digital biomarker of diabetes from smartphone-based vascular signals Nocturnal low glucose detection in healthy elderly from one-lead ECG using convolutional denoising autoencoders Precision medicine and artificial intelligence: a pilot study on deep learning for hypoglycemic events detection based on Development of a deep learning model for dynamic forecasting of blood glucose level for type 2 diabetes mellitus: secondary analysis of a randomized controlled trial Deep learning models for the prediction of intraoperative hypotension Artificial intelligence for early prediction of pulmonary hypertension using electrocardiography Smartphone-based diagnostic model for hypertension using features from photoplethysmogram Intradialytic hypotension related episodes identification based on the most effective features of photoplethysmography signal Photoplethysmography and deep learning: enhancing hypertension risk stratification Artificial intelligence for detecting mitral regurgitation using electrocardiography Classification of aortic stenosis using conventional machine learning and deep learning methods based on multi-dimensional cardio-mechanical signals Classification of aortic stenosis using time-frequency features from chest cardio-mechanical signals Deep learning-based algorithm for detecting aortic stenosis using electrocardiography Genetic-fuzzy logic model for a non-invasive measurement of a stroke volume Detection of congestive heart failure based on LSTM-based deep network via short-term RR intervals Artificial intelligence algorithm for screening heart failure with reduced ejection fraction using electrocardiography Energy-efficient real-time myocardial infarction detection on wearable devices Artificial intelligence algorithm for predicting cardiac arrest using electrocardiography Artificial intelligence-enhanced electrocardiogram for the early detection of cardiac amyloidosis A deep learning algorithm to detect anaemia with ECGs: a retrospective, multicentre study Data-driven assessment of cardiovascular ageing through multisite photoplethysmography and electrocardiography Forecasting one-day-forward wellness conditions for community-dwelling elderly with single lead short electrocardiogram signals The apnea-ECG database PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals The European ST-T database: standard for evaluating systems for the analysis of ST-T changes in ambulatory electrocardiography Heart for heart Abrupt changes in fibrillatory wave characteristics at the termination of paroxysmal atrial fibrillation in humans Long-term ST database: a reference for the development and evaluation of automated ischaemia detectors and for the study of the dynamics of myocardial ischaemia The impact of the MIT-BIH arrhythmia database A new method for detecting atrial fibrillation using RR intervals A noise stress test for arrhythmia detectors Multiparameter Intelligent Monitoring in Intensive Care II: a public-access intensive care unit database MIMIC-III, a freely accessible critical care database Protocol of the SOMNIA project: an observational study to create a neurophysiological database for advanced clinical sleep monitoring Survival of patients with severe congestive heart failure treated with oral milrinone An open-access long-term wearable ECG database for premature ventricular contractions and supraventricular premature beat detection lated alterations in the fractal scaling of cardiac interbeat interval dynamics Vital recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices Predicting the onset of paroxysmal atrial fibrillation: the computers in cardiology challenge Electrocardiogram signal quality measures for unsupervised telehealth environments TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise Nutzung der EKG-signaldatenbank CARDIODAT der PTB über das internet PTB-XL, a large publicly available electrocardiography dataset A 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients Ambulatory cardiac biosignals: from mirage to clinical reality through a decade of progress Smart wearable devices in cardiovascular care: where we are and how to move forward ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry Smartwatch algorithm for automated detection of atrial fibrillation Wearable devices for cardiac rhythm diagnosis and management