key: cord-0025419-erdlhk2l authors: Rahman, Mohammad Sofiqur; Yoshida, Naoko; Tsuboi, Hirohito; Karmoker, James Regun; Kabir, Nadia; Schaefermann, Simon; Akimoto, Yoshio; Bhuiyan, Mohiuddin Ahmed; Reza, Md. Selim; Kimura, Kazuko title: A comprehensive analysis of selected medicines collected from private drug outlets of Dhaka city, Bangladesh in a simple random survey date: 2022-01-07 journal: Sci Rep DOI: 10.1038/s41598-021-04309-1 sha: eba647e068dae57b53722bf95efe1764fc99a9b9 doc_id: 25419 cord_uid: erdlhk2l Comprehensive data are needed to prevent substandard and falsified (SF) medicines as they pose a major risk to human health. To assess the quality of selected medicines, samples were collected from random private drug outlets of Dhaka North and South City Corporation, Bangladesh. Sample analysis included visual observation of the packaging, authenticity of the samples, legitimacy and registration verification of the manufacturer, physicochemical analysis, and price. Chemical analysis of the samples was performed using a portable Raman spectroscopy and high-performance liquid chromatography according to the pharmacopoeia. Several discrepancies were noted in the visual observation of samples. Among the 189 collected samples of esomeprazole (ESM), cefixime (CFIX), and amoxicillin-clavulanic acid (CVA-AMPC), 21.2% were confirmed to be authentic, 91.3% manufacturers were confirmed legitimate, and 2.1% of all samples were unregistered. Chemical analysis of the samples revealed that 9.5% (95% CI 5.7–14.6) of samples were SFs. Falsified samples and quality variation in the same generic branded samples were both detected by Raman spectroscopic analysis. Overall, sample prices were satisfactory relative to the international reference price. This study documents the availability of poor-quality medicines, demonstrating the need for immediate attention by the national medicine regulatory authority. Reporting system and ethical approval. This project was a collaborative effort between Kanazawa University, Japan and University of Asia Pacific, Bangladesh represented by Professor K.K. All the methods in this study were carried out in accordance with relevant guidelines and regulations. The study was conducted and reported according to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines, Medicine Quality Assessment Reporting Guidelines (MEDQUARG), and WHO Guidelines on the conduct of surveys of the quality of medicines [28] [29] [30] . The importance of good ethical practice for such studies has been discussed recently by Tabernero et al., to maintain the privacy and confidentiality of the surveyors and the surveyed; however, institutional review board approval was not required for this study at Kanazawa University as it did not involve any live vertebrates, experimental animal and/or human subject research 31 . Regulatory approval was taken in writing from the Directorate General of Drug Administration (DGDA) under the Ministry of Health & Family Welfare, Government of the People's Republic of Bangladesh on the condition that raw data sharing will be limited, and confidentiality with respect to the name of the manufacturers or their commercial brand will be maintained. The final report of this study was submitted to the DGDA in September, 2019. Study settings and design. The entire healthcare system of Bangladesh serves an estimated population of 161.03 million, with a density of 1,077 people per square km and a population of the metropolitan area of the capital city Dhaka of approximately 17 million [32] [33] [34] . Target medicines were purchased from private retail drug shops (retail shops, wholesale shops selling retail medicines, and a shop in a private hospital located in Dhaka City Corporation of Dhaka District) during April, 2018, without prescriptions, using the mystery buyer approach (Supplemental Fig. S1 ). A list of shops was obtained from the DGDA and the outlets were classified according to area (Thanas included in the Dhaka North and South City Corporation) and included in the main database. Among the 4400 outlets in Dhaka district listed in the DGDA database, 831 outlets were excluded due to predetermined criteria (for example, Savar, Ashulia). In total, 1,885 outlets from Dhaka North City Corporation (Adabar, Badda, Banani, Gulshan, Kafrul, Khilkhet, Mirpur, Mohammadpur, Pallabi, Shaymoli, Tejgaon, and Uttara) and 1684 outlets from Dhaka South City Corporation (Dhanmondi, Jatrabari, Khilgaon, Kotowali, Motijheel, Paltan, Ramna, Rampura, Shabujbag, and Shahbag) were included in the final list of outlets. The final list of outlets was randomized using a randomization table and the samples were purchased according to the randomized list by four mystery buyer teams over 9 d, including a one-day pre-sampling to demonstrate the sample collection approaches 35 . The required sample size (188) was calculated with a 5% margin of error and 95% confidence levels assuming the sample proportion to be 15%. Target medicines were esomeprazole (ESM), cefixime (CFIX), and amoxicillin-clavulanic acid (CVA-AMPC), and they were chosen based on the frequency of use, availability, and characteristics of the medicines that are included in the essential medicine list of WHO 36 (ESM as omeprazole). www.nature.com/scientificreports/ Sampling terms. There were four sampling teams, each containing three fourth year Bachelor of Pharmacy students and one supervisor. The samplers and supervisors were trained and instructed on how to purchase the medicines. Samples were purchased by selecting at least one sample of either ESM, CFIX, or CVA-AMPC from the visited outlets over 9 d. Variations in the generic brands and strength depended on the availability of the samples in the outlet during the purchase. In principle, the primary approach was to collect 100 dosage units per sample (not less than 40 units per sample in case of unavailability). Medicines collected from the same outlet, labeled with the same international nonproprietary (INN) name, brand name, strength, size, batch/lot number, and manufacturing and expiry dates were considered as one sample. The outlet type, date of purchase, price paid, brand name, formulation, batch number, date of manufacture, and expiry date were recorded using a standard sampling form for every sample purchased. Every sample was placed in an individual ziplock bag together with the recoded data and securely stored in an air-conditioned room (20-25 °C) until analysis. Sample analysis. Collected samples were shipped within one month to the analytical laboratory at Kanazawa University for analysis. Sample analysis consisted of visual examination of the samples (packages, strips, and tablets/capsules), an investigation of the authenticity of the product by the manufacturer, verification of the legitimacy of manufacturers, registration verification of the product in Bangladesh by DGDA, Raman scattering, and pharmacopoeial analysis. Details of the packaging condition and label information were recorded carefully, according to the tabulated checklist. During observation, the packaging and labeling, physical appearance of the tablet/capsule, batch number, manufacturing date, and date of expiration, were examined according to the WHO guidelines on the conduct of surveys of the quality of medicines and the International Pharmaceutical Federation (FIP) checklist for visual inspection of medicines 37, 38 . For confirming the authenticity, a detailed questionnaire was sent to each manufacturer to confirm the authenticity of the product. Each questionnaire provided detailed information about the product, including manufacturer, batch number, date of manufacture and expiry date, dosage, and strength of the product, as recommended by the WHO 29 . Verification of the legitimacy of the manufacturers and the registration status of each product was evaluated by visual inspection of the packaging, and then by sending a questionnaire along with the package and photographs of the sample to the DGDA to confirm the legitimacy of the manufacturers and the registration of the product 39 . Chemical analysis. Laboratory analysis of all the samples was carried out before the expiration date. Pharmaceutical analysis of the samples was performed according to the British and United States pharmacopoeia, with slight modifications as specified in the sample package of the respective dosage form for each of the medicines [40] [41] [42] [43] [44] [45] . Some minor adjustments were made to the analytical procedure of ESM and CFX indicated in the pharmacopeia monograph. They are described in the Supplemental File S1. The pharmacopoeial quality assessment included potency (drug content), content uniformity test, and dissolution test. The reference standards for ESM (as omeprazole), CFIX, amoxicillin, and clavulanic acid, and the internal standards (IS) lansoprazole, metronidazole, and cefadroxil, were all purchased from the United States Pharmacopeial Convention. HPLC-grade acetonitrile and methanol, tetrabutylammonium hydroxide solution ([(CH 3 CH 2 CH 2 CH 2 ) 4 N]OH), sodium di-hydrogen phosphate (NaH 2 PO 4 ·2H 2 O), di-sodium hydrogen phosphate (Na 2 HPO 4 ), tri-sodium phosphate (Na 3 PO 4 ·12H 2 O), potassium di-hydrogen phosphate (KH 2 PO 4 ), and other chemicals of reagent grade were purchased from Wako (Wako Pure Chemical Industries, Ltd., Osaka, Japan). For the calibration curves, individual stock solutions were prepared by dissolving reference standards in the corresponding solvent (Supplemental File S1) at a concentration of 0.2 mg/mL. Afterwards, stock solutions were diluted to 5.0, 10.0, 20.0, 30.0, and 40.0 μg/mL aliquots to obtain five calibration samples. The concentration of all IS solutions was 20.0 μg/mL, and these were mixed with the each of the diluted reference standard solutions and sample solutions. For the assay and content uniformity sample solutions were prepared using the same solvent and diluted to the same concentration as the reference standard solutions. The dissolution test of the samples was conducted with an NTR-VS 6P dissolution apparatus (Toyama Sangyo Co. Ltd., Osaka, Japan), and the assay was carried out by HPLC. The circular dichroism (CD) spectra of the enantiomer of omeprazole (ESM) was detected and measured using a Jasco CD-PDA detector (Chiral detector-CD 2095, and Photo diode array-MD 2018 Plus, Jasco, Tokyo, Japan) equipped with an AS-950 Jasco auto-sampler. The HPLC system for analyzing CFIX and CVA-AMPC samples consisted of a Prominence HPLC equipped with auto-sampler (SIL-10AD) and Ultraviolet-Photo Diode Array Detector (UV-PDA, SPD-20A/20AV Series; Shimadzu, Kyoto, Japan). Mechanical calibration and performance verification tests were performed before sample testing for performance qualification to ensure the absence of technical and mechanical errors. Test methods and system suitability for each medicine were validated according to USP 41 46 . The five-point calibration curves were prepared with three replicates of injections for each vial of the calibrators, and three replicates were used during sample analysis. Calculations for quantitation were based on the peak area ratios of the analyte relative to its corresponding IS using weighted (1/x) regression. The linearity of the curves was assessed by linear calibration using the correlation coefficient (r). The r was determined using the mean of three replicates at each level of the calibrators. Details of the analytical condition, dissolution test, chromatographic condition, and the reference for compliance criteria are summarized and presented in Supplemental where, x is the mean of an individual content expressed as a percentage of label claim; M is the reference value, K is acceptability constant, and S is the sample standard deviation. In the dissolution test, Q values for evaluation were as follows: ESM in acid, not more than (NMT) 10% of the label claim; ESM in buffer, not less than (NLT) Q = 75% of the label claim; CFIX, Q = 75% of the label claim; amoxicillin, = 85% of the label claim; and clavulanic acid, Q = 80% of the label claim. Raman scattering analysis of the samples. Raman scattering analysis was performed to analyze the molecular structure by light scattering using a portable Raman scattering analyzer (Inspector 500, SciAps Inc., Laramie, WY, USA). The instrument was equipped with higher wavelength Raman excitation, consisting of a 300 mW power source with a 1030 nm wavelength Class III B laser and a cooled Type III-IV semiconductor detector array (spectral range 100-2500 cm −1 ). The exposure time was set at the default (maximum 8.0 s). Each of the tested samples was analyzed for five consecutive spectral data on the front, back, and side, thus generating 45 spectral data. The average of these 45 spectral data was then calculated and analyzed. Tablet samples were taken out of the blister and kept directly in front of the laser source. For capsule samples, granules were separated from the gelatin shell and kept in a thin and transparent glass tube. The glass tube was positioned in front of the laser source (three times each), and the Raman spectral data were recorded and compared with those of the other samples of the same brand or the authentic samples of the same brand. The concordance rate (match score) was calculated from the Pearson's correlation coefficient between the test sample spectrum and the reference sample spectrum on a common interpolated wavenumber scale using the NuSpec Pro software (SciAps Inc., Laramie, WY, USA), and the Raman spectral data were input into the Unscrambler (CAMO Software, Oslo, Norway) for principal component analysis (PCA). The PCA model was constructed for three sets of samples, wherein each set represents five points, averaged from the 45 spectral data obtained from the different regions of each sample. Spectral data of the reference samples were used for the PCA model as the calibration set. The optimal number of principal components was determined from the internal cross-validation where authentic samples were treated as the reference set 47 . Spectral pre-processing involved the application of Savitzky-Golay smoothing and differentiation filter (second-degree polynomial and first derivative) to remove noise and baseline signals. We then performed unit-area normalization by applying Standard Normal Variate to the smoothed and differentiated signals 48-50 . Price. The prices of samples were recorded in local currency (BDT) and converted from local currency to US Dollar (USD), based on the exchange rate given by the money exchange office in Dhaka on April 09, 2018 (US$1 = Tk 83.5). Prices for the different strengths of medicine were calculated individually for each of the samples and expressed as the median unit price of an individual medicine; the observed individual prices were compared to an international reference price as recommended by the WHO/HAI manual 51 (IBM Corp., Armonk, NY, USA). The Fisher exact test was performed online (Extended-http:// aoki2. si. gunmau. ac. jp/ exact/ fisher/ getpar. html). A significance probability of 1% was used for these analyses. Confidence intervals were calculated using descriptive statistical analysis. The criterion of significance was taken as p < 0.05. Means, standard deviations, and coefficient of variation (CV%) were calculated using Microsoft Excel 2016. Graphs for figures were generated using GraphPad Prism (version 9.0, GraphPad Software Inc., San Diego, CA). Sample description. A total of 189 samples were collected in this study. Samples were purchased by selecting at least one sample of either ESM, CFIX, or CVA-AMPC from the 210 outlets visited. From the list, 28 (13.3%) outlets had to be excluded as the shops were either non-existing or found closed at the time of sampling. Additionally, two ESM samples, two CFIX samples, and three CVA-AMPC samples were provided by the manufacturers upon request. All the collected samples were found to be domestically manufactured; 100 samples (54.9%) were collected from Dhaka North City Corporation area and the rest (45.1%) were collected from Dhaka South City Corporation. Samples from retail shops accounted for 78.6% of the total samples collected, whereas 20.9% samples were collected from wholesale shops selling retail medicine. Only one CFIX sample was collected from a shop inside a hospital facility. No provider asked to see a medical prescription from the buyers during the purchase of samples. Further details of the collected samples are summarized in Table 1 . Samples were collected only from shops listed by the DGDA (no samples were collected from illegal shops). During sample collection, details regarding the storage conditions of the medicines were recorded. Among the visited shops, only 13 (7.2%) shops were found to be equipped with air-conditioning, although four of them were not functional; the remaining shops (92.8%) did not have air-conditioning. However, there was no significant temperature difference (p = 0.117) between shops with airconditioning (30.1 ± 1.5 °C) and without air-conditioning (31.7 ± 2.5 °C). Although a significant humidity (rela- www.nature.com/scientificreports/ tive humidity-RH) difference was observed (p < 0.05) between shops with air-conditioning (52.2% RH ± 8.7) and without air conditioning (59.6% RH ± 7.9). Sample observation. Samples were checked for 46 points according to the FIP Tool for Visual Inspection of Medicines 38 . Overall, packaging analysis of the samples was satisfactory. One ESM sample had two different batch numbered strips from the same secondary packaging box (D-106). Two samples (A-102, B-213) did not have an insert inside the box, one of which (B-213) was confirmed to be falsified after chemical analysis. One CVA-AMPC sample (C-308) was found with a spelling error in the insert regarding the strength of the product (Supplemental Fig. S2 ). Although CVA-AMPC is usually film coated, no film coating was observed on the tablets from this sample when opened during analysis. The tablet surfaces were also dirty with speckles (Supplemental Fig. S2 ). The sample was also suspected to be falsified after chemical analysis. Authenticity, legitimacy investigation, and registration verification. The names and addresses of manufacturers and wholesalers were identified through the product packages and manufacturer websites. Questionnaires were sent to the respective manufacturers of ESM, CFIX, and CVA-AMPC by e-mail in July 2018, and 5 manufacturers out of 33 gave their response by 04 September 2018. Forty samples (21.2%) out of 189 were confirmed as genuine products by four manufacturers, and no falsified samples were reported (Table 2) . Most manufacturers have a contact e-mail address, but in many cases, we did not obtain a response, even after sending a reminder mail to non-responders. The results of our authenticity investigation are summarized in Table 2 . Although questionnaires were sent to the DGDA by e-mail in July 2018, we initially received no response. According to our first stage of registration verification, fifty-one out of 62 ESM samples (85%) were verified for registration from the DGDA drug product registration list in their website. Eight (13.3%) samples could not be verified, as the registration numbers in the package were different to the DGDA registration number. While one sample (B-114) was registered for tablet dosage form, we collected capsules from this manufacturer with the same registration number. In case of CFIX samples, n = 47 samples (78%) could not be verified due to differences in the registration number on the package and in the DGDA list. Moreover, one manufacturer was not listed as a registered manufacturer of CFIX raising legitimacy concerns. For CVA-AMPC, 52 out of 60 samples (86.7%) from three manufacturers had different registration numbers from those in the DGDA list and therefore could not be verified initially. At the beginning of 2020, DGDA crosschecked the registration status of the collected samples and confirmed that some newly changed registration numbers had not been updated on their site. However, two manufacturers were identified who were not licensed to produce CFIX. Another manufacturer was only licensed to produce a tablet dosage form of CFIX, although a capsule dosage form from this manufacturer was available on the market. The results of our registration verification of the samples and manufacturers are summarized in Table 2 . Results of chemical analysis. Among all the tested samples, 18 samples (0.095; 95% CI 5.3-13.7) were found to be non-compliant after the final stage of at least one of the pharmacopoeial tests. Among the non-compliant samples, two samples were identified as falsified medicine (CFIX, 1; CVA-AMPC, 1). Raman spectroscopy and HPLC analysis of the falsified samples confirmed the absence of any APIs. The remaining 171 samples (90.5; 95% CI 86.3-94.7) were compliant with all pharmacopoeial tests according to the declared pharmacopoeia, i.e., USP or BP. The results of our chemical analyses are summarized in Table 3 . The average quantity of all samples compliant in the potency test was 100.1% ± 4.7 (95% CI 99.4-106.0) with a minimum mean of 90.1% API and a maximum mean of 111.8% API. The frequency distribution chart of all samples in the potency test is shown in Fig. 1a . In contrast, the average quantity of all the non-compliant samples in the potency test was 78.8% ± 7.1 (95% CI 73.7-83.8). Among the non-compliant samples, we identified samples with a minimum mean potency of 68.5% and a maximum mean potency of 86.2%. High inter-unit variability was observed for nine (4. 8; 95% CI 1.7-7.8) of the total collected samples. Notably, among the non-compliant samples in the content uniformity test, none were from the ESM or amoxicillin samples. www.nature.com/scientificreports/ In the dissolution test, the average percent release of API in the dissolution medium within the specified time was 93.3% with ± 9.5 (95% CI 92.1-94.5) for all the samples meeting pharmacopoeia acceptance criteria. The lowest amount of API released in the medium after the pharmacopoeia specified time was 71.2% and the maximum was 112.5%. The frequency distribution chart of all samples in the dissolution test is shown in Fig. 1b . Conversely, the mean percent release of API in the samples failing to meet the pharmacopoeia specified criteria in the dissolution test was 70.3% ± 10.0 (95% CI 63.6-76.9). The mean percent release in those samples was observed to be 55.7%, with a maximum of 93.4%. Surprisingly, all of the ESM tablets and granules kept their integrity Table 2 . Authenticity, legitimacy investigation, and registration verification of the samples and manufacturers. *Two esomeprazole samples were provided by the manufacturers upon request; **Two CFIX samples were provided by the manufacturers upon request; ***Three amoxicillin-clavulanic acid samples were provided by the manufacturers upon request; § One manufacturer of esomeprazole did not have manufacturing or marketing authorization to produce and sell esomeprazole capsule; ¶ One manufacturer was not listed as a registered manufacturer of CFIX and manufacturing license was cancelled for another manufacturer by DGDA but their samples were circulating in the market and one of their sample was identified as falsified; † Combining all samples total number of manufacturers were n = 33; a One esmeprazole sample was provided by AstraZeneca which was used a standard esomeprazole sample. www.nature.com/scientificreports/ www.nature.com/scientificreports/ during the acid stage of the dissolution test. Nevertheless, the dissolution rates of some samples were low in the buffer stage of the dissolution test, releasing less ESM than the pharmacopoeia specified range (Fig. 1c) . Among the non-compliant samples, one ESM sample (B-103) demonstrated extreme failure, as two units showed as low as 1.3% release of API in the medium in the second stage of the dissolution test. Mean Quantity of the API of non-compliant samples versus their mean dissolution rate in the dissolution test are presented in Fig. 1c-f . As demonstrated in Fig. 1e and f, the potency and dissolution rate of AMPC in the CVA-AMPC samples were within the compliance range. Nevertheless, they were non-compliant due to the lower content of CVA in the co-amoxiclav samples. In spite of having lower potency than the declared amount, a comparatively higher dissolution rate was observed for CVA (Fig. 1f) . Raman scattering analysis coupled with match score and PCA. Raman spectroscopy was employed to explore the distinctive behavior between compliant and non-compliant samples, principally by match score and PCA. Raman spectra were analyzed after preprocessing and were subjected to PCA to investigate the similarity of chemical components between and/or among the samples. In most of the cases, non-compliant samples were compared against the authentic samples, if available. Otherwise, collected compliant samples from the same manufacturer were chosen for comparison. In the case of ESM samples, some manufacturers' samples showed variances in chemical analysis, where some samples of the same brand were compliant while others were not. The results were further confirmed by Raman analyses and their PCA (Fig. 2) . Compliant and noncompliant representative samples from those manufacturers showed a variation in the match score and a wide distribution on the score plot, suggesting significant differences among samples even though they were of the same generic brand. The correlation and variance among three different samples from the same manufacturer were analyzed using PCA on the basis of their compliance and non-compliance in the pharmacopeial analysis ( Fig. 2a-d) . Although a more number of representative samples could provide more precise evidence, a negative correlation was observed in PC1 between the compliant and non-compliant samples (Fig. 2b,d) . In PC2, a positive correlation was observed between two non-compliant samples. As shown in Fig. 2e and f, another ESM sample (PS-006) showed variation in the strips and batch number in the same packaging, as discussed in the observational analysis results. Granules from both the strips showed a very poor dissolution rate (59.2% and 59.0%) in the dissolution medium. Notably, another ESM sample (D-106) manufactured by the same manufacturer was found compliant. To investigate whether the observed differences between the reference and test samples were not just because of the batch-to-batch variation, the dissolution profiles of the two reference samples (authentic samples obtained from the manufacturers) were analyzed together. The reference samples almost overlapped on the different PCs, indicating that the between-batch variation was negligible. Inconsistencies in the quality of the same generic brand samples from the same manufacturer were also observed in samples of CFIX and CVA-AMPC. In case of CVA-AMPC, though an authentic sample from a manufacturer failed to comply with the acceptance criteria, two samples out of four collected samples from this manufacturer were found to be compliant. Two authentic samples were separately provided by this manufacturer upon request. There is a possibility that any discrepancies in the physicochemical analyses between these samples may have occurred as a result of degradation of clavulanic acid resulting from the ineffective film coating (Sample B-315 in Fig. 3a and b; Fig. 3 in Supplemental File S2). Since the tablets in the samples from this manufacturer were packaged in strip, we assume that the chipping was caused by mechanical stress, and that it resulted in the permeation of moisture and consequent degradation of clavulanic acid 53-55 . Detection of falsified CFIX and CVA-AMPC. There was a reasonable level of agreement between the HPLC analyses and Raman spectroscopic analyses. In both the chromatographic and spectroscopic analyses, one CFIX and one CVA-AMPC sample appeared to be falsified (Figs. 4 and 5) . The packaging labels of these samples stated that one contained CFIX and one contained CVA-AMPC, although no API was detected in either the assay or the spectroscopic analysis of these samples (see Sample B-213 in Figs. 4b and 5a ; and Sample C-308 in Figs. 4d and 5b; Fig. 2 in Supplemental Fig. S2 ). In case of the CVA-AMPC sample, the packaging was almost identical to the compliant samples from the same manufacturer. However, close observation of the packaging and insert showed a mistake in the insert (Fig. 2 in Supplemental File S2). For the CFIX sample, no comparator was available. To quantify the API, ten units of suspected CFIX sample and five units of suspected CVA-AMPC sample were assayed by HPLC, respectively. No chromatogram peak was observed with either of the samples (as described in Figs. 4 and 5) . Additionally, 6 units of CVA-AMPC were used for the dissolution test that showed no disintegration of the drug in the medium (remained intact). Out of 20 collected CVA-AMPC samples that were manufactured by this manufacturer, one sample was found to be falsified. Presumably, the falsified sample had successfully mimicked the original. Further analysis of these samples was performed by Raman Spectroscopy, and the resulting spectra were markedly different from those of the reference standards and the other compliant samples (Figs. 3c and 5) . Prices of medicines. The discrepancy in price for all medicines was summarized by the minimum, 25th percentile, median, and maximum price values relative to the International Reference Price (IRP) 47 . The median unit price of a 20 mg ESM capsule was 0.084 ± 0.01 USD (minimum, 0.06 USD/unit; maximum, 0.102 USD/ unit). The tablet formulation of 20 mg ESM had a median price of 0.06 ± 0.01/unit (minimum, 0.056; maximum, 0.078/unit). The price of a 20 mg ESM capsule was slightly higher than that of the 20 mg tablet, but not significantly. The Management Sciences for Health (MSH) price comparator was not available for ESM, although it's MPR was significantly higher (p < 0.05) than that of omeprazole. Compliant ESM samples had a slightly higher price than the non-compliant ESM samples, although the difference was not significant (Fig. 6a,b) . www.nature.com/scientificreports/ The median price of 200 mg CFIX was 0.419 ± 0.04 USD (minimum, 0.314 USD/unit; maximum, 0.603 USD/ unit) (Fig. 6a,c) . The CFIX price was significantly higher than the MSH median price (t-test, p < 0.001). However, the MPR for CFIX was found to be 2.54. An MPR of 1 or less is commonly interpreted as efficient procurement in the public sector, while an MPR below 3 is considered acceptable for the private sector 56 . All of our samples were procured from private retail shops (the authentic samples were not included in the price calculations). One sample of CFIX was 400 mg and the price was 0.60 USD. The minimum price paid for 625 mg CVA-AMPC was 0.24/unit (maximum, 0.395/unit; median 0.383/unit), which was significantly higher than the MSH price (t-test, B-102, B-111 , and C-104) samples of manufacturer 'X' . Differences were observed between the samples in both HPLC and the Raman spectra, despite the sample being from the same manufacturer. Match scores between sample AA-001 (authentic sample provided by the manufacturer) and A-113, AA-001, and B-102, and A-113 and B-102 were 97%, 95%, and 96% respectively; (b) PCA score plot of the representative samples AA-001, A-113, and B-102 in the PC1-PC2 plane. PC-1 accounts for 83% of the variance in the data, while PC-2 accounts for 4% explaining 87% of the total variance. According to the chosen separation distance (from the origin), it was possible to identify at least two clusters, one with samples showing poor dissolution rate in the buffer stage and another with samples releasing required amount of drug; (c) Spectra obtained from the compliant (A-103, A-104, C-114, D-101, and D-114) and non-compliant (C-106 and D-108) samples of manufacturer 'Y' . Observed match scores between B-103 and C-106, B-103 and D-108, and D-108 and C-106 were 96%, 95%, and 93%, respectively; (d) PCA score plot of the representative samples B-103, C-106, and D-108 in the PC1-PC2 plane. PC-1 accounts for 67% of the variance, while PC-2 accounts for 6% thus explaining 73% of the total variance. Samples from manufacturer 'Y' projected in that PC space are distributed in two clusters with differences in the first and second PC directions; (e) Spectra obtained from the compliant (D-106) and non-compliant (PS-006) samples of manufacturer 'Z' . As described in the text, sample PS-006 had two different types of strips with different batch numbers and expiry dates. Match scores between D-106 and PS-006-E-0320 (1), D-106 and PS-006-E-0420 (2), and PS-006-(1) and PS-006-(2) were 83%, 80%, and 86%, respectively; (d) The two groups of projected samples are separated mainly along the PC1 direction PC-1which accounts for 82% of the variance, while PC-2 accounts for 9% of the variance in the Raman spectra of those samples. www.nature.com/scientificreports/ p < 0.001). For 625 mg CVA-AMPC, the MPR was found to be 2.35. No significant differences were observed between compliant and non-compliant samples of either CFIX or CVA-AMPC (Fig. 6a,d) . Recent research has revealed that an alarming percentage of analyzed medical products in LMICs were found to be unacceptable in terms of quality, with the additional concern that SF antibiotic could lead to drug resistance due under-dosing or no dosing at all 9,57,58 . It is important that tragic events like that reported in Bangladesh in 1995 are not repeated, especially in the Covid-19 pandemic era 21, 59 . Despite achieving remarkable health and pharmaceutical improvements since gaining independence in 1971, adequate reporting of the quality of medicines using tested methodological practices has not been accomplished in Bangladesh 60 . This is the first comprehensive analytical study documenting the quality of selected medicines in private drug outlets in Bangladesh. A summary of the study has been presented in Fig. 7 as a flow chart. The present study reports the analytical results from medicines for a non-communicable disease and two antibiotics, including one combination drug, as representative medicines. Overall, the quality of the majority of the samples analyzed was revealed to be good; more than 90% of the analyzed samples collected from the Dhaka City Corporation region complied with the pharmacopoeial reference ranges and were found to be of acceptable quality ( www.nature.com/scientificreports/ of substandard medicines in our study was found to be 8.5% (95% CI 4.5-12.4), and this was higher than the prevalence of falsified medicines 1.1% (95% CI − 0.4-2.5). In total, these results indicate a prevalence of 9.5% for SF medicines, lower than the assumed prevalence of 15% (p < 0.05; 95% CI 5.7-14.6). While most of the samples were of good quality, 4.2% of samples (95% CI 1.4-7.1) contain less API than the stated amount in their packaging (Table 3) . Another important observation was the uniformity of the content, with 4.9% of samples demonstrating high inter-sample variation; these were found to be non-compliant according to the 'acceptance value (AV)' set by the pharmacopoeia. The permissible range of AV values set by the pharmacopoeia was established to ensure that all individual units within a sample have a sufficient amount of the declared API. Indeed, it is essential that the patient receives a dosage close to that claimed in the label. However, in the cases reported above, it cannot be stated with certainty that every unit of the sample contained the exact same amount of API. The drug dissolution test is a good predicator for the sample performance test, while allowing observation of physicochemical changes in tablets/granules in capsules [61] [62] [63] . The results presented in this study demonstrate that 5.3% samples (95% CI 2.1-8.6) were non-compliant (including all tested samples but excluding the falsified samples). The poor dissolution rates of the samples were a persistent problem, an observation which had previously been reported in our studies 60, 61, 64, 65 . As an essential indicator of bioavailability and drug quality, the dissolution test has not been given as much attention as it deserves 62, 66, 67 . Despite the fact that all of the ESM samples contained the stated amount of API, a poor dissolution rate was observed in the buffer stage of the dissolution test in 10.9% of the ESM samples (Table 3 ; Figs. 1 and 4) . HPLC analysis detected one inconsistent ESM sample, Figure 5 . Raman spectra obtained from the falsified CFIX (B-213) and CVA-AMPC samples. Each spectrum represents the average of a set of 45 spectra. Five spectra were acquired from the different regions of the sample in solid form, and these were averaged. (a) Raman spectrum of falsified CFIX sample and two other reference samples obtained from two different manufacturers. Inset spectrum was acquired from the reference standard CFIX; (b) Raman spectra of falsified and reference CVA-AMPC sample obtained from the same manufacturer. The reliability of the findings was further supported by the Raman spectroscopy results, which also confirmed the detection of two falsified medicines. The status of suspect samples identified during a visual observation using the FIP checklist was confirmed by the chemical analysis result (for example, sample D-106 appeared to be substandard and B-213 appeared to be falsified). However, packaging analysis alone could not detect additional falsified CVA/AMPA medicines (Figs. 4 and 5; Supplemental Fig. S2 ). Identical packaging from falsified samples could not be distinguished from that of the other samples stated to be manufactured by the same manufacturer, even after close observation of the packaging. In our study, handheld Raman spectroscopy was a practical and useful tool for the screening of suspicious samples, facilitating both identification of and characterization of suspicious samples (Figs. 2, 3, and 5) . Samples showing different chromatographic analysis result but similar spectra could be differentiated using principal component analysis (PCA) of the Raman spectra (Figs. 2 and 3 ). One falsified sample of CFIX and one falsified sample of CVA-AMPC were initially identified using the handheld Raman spectroscopy device, demonstrating its usefulness for the detection of falsified samples. Hence, this comparatively low-cost device may prove a useful tool in field settings requiring quality analysis. www.nature.com/scientificreports/ Despite the satisfactory results obtained in our chemical analyses, falsified medicines threaten the national supply and distribution chain (Figs. 3, 4, 5) . No one test can serve as an ultimate tool for the detection of SF medicines, and the roles of MRAs and manufacturers remain in question, as the anticipated responses from the stakeholders regarding product authentication and legitimacy verification were below the expected level. In our authenticity investigation, a response was received from only five manufacturers, confirming the authenticity of 21.2% samples ( Table 2 ). Better cooperation from the manufacturers in response to questionnaires is essential for any authenticity investigation. Furthermore, considering the export potential of pharmaceuticals, which is largely driven by domestic manufacturers, the governing authorities should focus on the active and effective regulatory surveillance of manufacturers. Data from our study suggests that there is substantial scope for improving the storage situation of the distributed medicines, and for lowering the prices of the medicines in the private drug outlets. The observed sub-standard storage conditions for the medicines may be linked to degradation of the medicines, although no relationship could be established between storage and quality of medicines in our study 68 . As reported above, the prices for the collected medicines were slightly elevated relative to the international standards (Fig. 6) , although the prices were not excessive. This suggests that the revised health policy intervention may be necessary to reduce the catastrophic out-of-pocket expenditure of patients, especially during long-term treatment. The strength of this study is that it presents a comprehensive analysis of the collected samples including all stage of pharmacopoeial analysis for potency, a dissolution test using HPLC, and Raman spectroscopy combined with chemometrics. The sample size for this study was not large enough to allow prediction of the influencing factors and a comparative analysis. However, given the limited personnel resources, a larger sample size would limit the scope for such a detailed analysis. Indeed, longer processing times would make it difficult to complete the analysis before the expiry date of the collected samples. Finally, the study is not nationally representative and should be interpreted with caution, as samples were only collected from one urban area of the Capital City and illegal or unlicensed shops were excluded. The threat of SF medicines exists in Dhaka City Corporation, although the proportion of SFs was revealed to be relatively lower than the estimated proportion. In addition, differences in the quality of the same branded sample from the same manufacturer may put the patient at risk. Therefore, the national MRA, in an active collaboration with the manufacturers, should identify hotspots for these life-threatening poor-quality medicines, and take prompt and effective action. In our study, a consensus was observed between the portable Raman spectroscopy results and the observational and authenticity analysis results thus, implying that scope for these screening techniques should be considered in the field detection and evaluation of medicines. A full-scale analysis, including a dissolution test, is essential to accurately estimate the prevalence of substandard and falsified medicines. www.nature.com/scientificreports/ All relevant data available for publication are within the manuscript and the supporting information. Public sharing and distribution of raw data has been restricted by the Directorate General of Drug Administration (DGDA), Bangladesh. Received: 13 February 2021; Accepted: 17 December 2021 Poor-quality medical products: Social and ethical issues in accessing "quality" in global health Impact of poor-quality medicines in the "developing Technologies for detecting falsified and substandard drugs in low and middle-income countries Expanding global access to essential medicines: Investment priorities for sustainably strengthening medical product regulatory systems #: ~: text= Subst andard% 3A% 20Also% 20cal led% 20% E2% 80% 9Cout% 20of,stand ards% 20or% 20spe cific ations% 2C% 20or% 20both. & text= Falsi fied% 3A% 20Med ical% 20pro ducts% 20that% 20del ibera tely ducts#: ~: text= Subst andard% 20and% 20fal sified% 20med ical% 20pro ducts% 20are% 20most% 20lik ely% 20to% 20rea ch A Study on the Public Health and Socioeconomic Impact of Substandard and Falsified Medical Products Collaborative health and enforcement operations on the quality of antimalarials and antibiotics in Southeast Asia Pilot study of essential drug quality in two major cities in India Substandard and falsified anti-tuberculosis drugs: A preliminary field analysis Characterization and identification of suspected counterfeit miltefosine capsules A collaborative epidemiological investigation into the criminal fake artesunate trade in South East Asia Qualitative insights into promotion of pharmaceutical products in Bangladesh: How ethical are the practices? The concept of essential medicines: Lessons for rich countries Achieves International Recognition in Quality Testing for Medicines Steps Up Efforts to Control Quality of Medical Products In vitro comparative quality evaluation of different brands of esomeprazole tablets available in selected community pharmacies in Chemical and bioassay techniques to authenticate quality of the anti-leishmanial drug miltefosine Fatal renal failure caused by diethylene glycol in paracetamol elixir: The Bangladesh epidemic Exploring the status of retail private drug shops in Bangladesh and action points for developing an accredited drug shop model: A facility based cross-sectional study Availability and rational use of drugs in primary healthcare facilities following the national drug policy of 1982: Is Bangladesh on right track Therapeutic drug use in Bangladesh: Policy versus practice Quality of medicines in resource-limited settings: Need for ethical guidance Field detection devices for screening the quality of medicines: A systematic review WHO. Essential Medicines and Health Products: WHO Member State Mechanism Strengthening the reporting of observational studies in epidemiology (STROBE): Explanation and elaboration WHO. Guidelines on the Conduct of Surveys of the Quality of Medicines Guidelines for field surveys of the quality of medicines: A proposal Ethical challenges in designing and conducting medicine quality surveys Government of the People's Republic of Urban-rural differences in disability-free life expectancy in Bangladesh using the 2010 HIES data Population profile and residential environment of an urban poor community in Dhaka USP. Guidelines for Sampling of Antimalarial Drug Samples: In the USP DQI Antimalarial Drug Quality Monitoring Project in Mekong Sub-region Countries Drugs: Guidelines for the Development of Measures to Combat Counterfeit Drugs Tool for Visual Inspection of Medicines Public health concerns for anti-obesity medicines imported for personal use through the internet: A crosssectional study Esomeprazole Magnesium. The Pharmocopeia of the United States of America The United States Pharmocopeial Convention Uniformity of Dosage Units. The Pharmocopeia of the What do we mean by validating a prognostic model Review of the most common pre-processing techniques for near-infrared spectra Smoothing and differentiation of data by simplified least squares procedures Detection method of falsified medicines by using a low-cost Raman scattering spectrometer combined with soft independent modeling of class analogy and partial least squares discriminant analysis WHO. Measuring Medicine Prices, Availability, Affordability and Price Components MSH. International Medical Products Price Guide Effects of packaging and storage conditions on the quality of amoxicillin-clavulanic acid: An analysis of Cambodian samples Postreconstitution stability of amoxicillin-clavulanic acid suspensions at tropical room temperature Solid-state stability and compatibility studies of clavulanate potassium The Global Health Expenditure Database Prevalence and estimated economic burden of substandard and falsified medicines in low-and middle-income countries: A systematic review and meta-analysis A link between poor quality antimalarials and malaria drug resistance COVID-19 and risks to the supply and quality of tests, drugs, and vaccines Universal health care in Bangladesh-promises and perils Erroneous formulation of delayed-release omeprazole capsules: Alert for importing countries Quality of omeprazole purchased via the Internet and personally imported into Japan: Comparison with products sampled in other Asian countries Dissolution testing for generic drugs: An FDA perspective A cross-sectional investigation of the quality of selected medicines for noncommunicable diseases in private community drug outlets in Cambodia during 2011-2013 A cross-sectional investigation of the quality of selected medicines in Cambodia in 2010 High failure rate of the dissolution tests for 500-mg amoxicillin capsules sold in Cambodia: Is it because of the product or the test method? Implementation of basic quality control tests for malaria medicines in Amazon Basin countries: results for the 2005-2010 period Degradation of artemisinin-based combination therapies under tropical conditions acquired funding that supported this study. All authors read and approved the final manuscript The authors are grateful for the support of the Japan Pharmaceutical Manufacturers Association (JPMA) and member companies for this project. Without the cooperation and efforts of JPMA, this project would not have been possible. We thank the Directorate General of Drug Administration (DGDA), Bangladesh for their kind support and cooperation. Authors also convey their gratefulness to the manufacturers in Bangladesh who were kind enough to provide us authentic samples of ESM, CFIX, and CVA-AMPC. This study was supported by Japan Pharmaceutical Manufacturers' Association (JPMA; 2018, Grant Number N/A, http:// www. jpma. or. jp/ engli sh/) received by Prof. K.K.). The funding bodies had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. The authors declare no competing interests. Supplementary Information The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-021-04309-1.Correspondence and requests for materials should be addressed to M.S.R. or N.Y.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.