key: cord-0024916-n8jj1si6 authors: Rostami, Nasrin; Alidadi, Hossein; Zarrinfar, Hossein; Ketabi, Damon; Tabesh, Hamed title: Interventional Effect of Nanosilver Paint on Fungal Load of Indoor Air in a Hospital Ward date: 2021-12-20 journal: Can J Infect Dis Med Microbiol DOI: 10.1155/2021/8658600 sha: 65153536112cb9673b4803cf12be06887a00a593 doc_id: 24916 cord_uid: n8jj1si6 Hospital ward environments contain various types of microorganisms, in which fungal agents are one of the main contaminants that may cause hospital-acquired infections. Regarding this, the aim of the present study was to evaluate the effect of nanosilver paint on reducing fungal contaminants of indoor air in an educational, research, and treatment center. Two rooms in the hematology ward were selected. One room was painted using usual paint (control room) and the other room was painted with paint containing nanosilver particles (experimental room). One hundred and twelve samples were collected using active (Anderson BioSampler) and passive (settle plate or open plate) air sampling techniques. The samples were incubated for 3–7 days at 35°C, and the positive fungal cultures were examined according to morphological and microscopic characteristics. Following active sampling, the mean and standard deviation of the number of colony-forming units (CFU/m(3)) of fungi colonies in the experimental and control rooms were 29.21 ± 17.99 and 22.50 ± 10.02 before intervention and 13.79 ± 6.20 and 31.07 ± 21.1 after intervention, respectively. Following passive sampling, the number of CFU/plate in the experimental and control rooms was 6 and 0 before and 1and 1 after intervention, respectively. The use of the nanosilver paint was effective in reducing air fungal contamination. Moreover, the active sampling method was more sensitive to measuring the concentration changes for fungal bioaerosols. Transmission of microbial pathogens through air is considered as an important way in indoor and outdoor environments [1] . High concentrations of microorganisms in air may be considered as an environmental risk, causing health problems in the indoor environments [2] . About 5-34% of indoor air pollution is caused by bioaerosols [3] . e results of epidemiological studies show that high concentrations of airborne microbes can be life-threatening and fatal [4] . Exposure to many microorganisms is inevitable in indoor environments such as hospitals [5] . It can be hazardous for hospitalized patients, especially those requiring long-term intensive care to exposure under the bioaerosols [6, 7] . Fungi are considered as one of the major sources of microbial contamination in indoor environments [1] . Fungal pollution of indoor environments depends on many factors such as temperature, moisture, ventilation, and organic matter present in building materials. Also, outdoor fungal spores may be transmitted through visitors, patients, and air conditioning [8] . Opportunistic fungal infections are usually reported in individuals with immune deficiency, such as hospitalized patients [7] . erefore, fungal bioaerosols should be reduced in hospitals because of the high-risk groups; those may be sensitive or vulnerable to these dangerous biological agents [5] . e use of nanoparticles, including silver nanoparticles, is one of the ways that has been considered as a medical disinfectant in recent years [9] . e antifungal properties of silver nanoparticles have been reported in many studies by various researchers [10, 11] . Lee et al. concluded that silver nanoparticles have successful fungicidal activity against dermatophytes and pathogenic fungi and could be used as potential disinfectants against human fungal diseases [12] . erefore, silver nanoparticles can be used as disinfectants due to their significant antimicrobial effect, along with a low toxicity and tolerance against different conditions. Although some nanoparticles clearly reduce the microbial load on various environments in laboratory settings, they have rarely been evaluated in welldesigned clinical studies for their effectiveness in hospital environments. erefore, the purpose of this study was to evaluate the effect of nanosilver paint on reducing fungal contamination of indoor air in an educational, research, and treatment center, Mashhad, northeast of Iran. Ethical approval was obtained from the Ethics Committee of Mashhad University of Medical Sciences, Iran (number: IR.MUMS.REC.1393.45). Design. An interventional study was conducted in hematology ward of Imam Reza Hospital in Mashhad, northeast of Iran. Two rooms of this ward were selected (an experimental and a control) and examined before and after intervention (in 2014). is ward was selected because of its special significance and sensitivity due to hospitalization of cancer patients undergoing chemotherapy. ey suffer immunodeficiency disorders, which are prone to hospitalacquired infections. Another reason for selecting this ward was the limited presence of visitors, as an interventional factor affecting the result of the study. Rooms. In this study, both control and experimental rooms were similar in terms of area, ventilation system, temperature conditions, pressure, humidity, sunshine direction, number of hospitalized patients, medical/nonmedical equipment, and the cleanup of the preexistent coating. Experimental room was coated with paint containing silver nanoparticles and control room was coated with ordinary paint, without any damp stains. e temperature and humidity of the experimental and control rooms were measured using a barometer (model PHB-318, Canada). To measure the concentration level of the fungal bioaerosols in indoor air of the hospital rooms, air sampling was performed twice a day. In the morning (8-9 am) and in the evening (5-6 pm), 14 times before and 14 times after the intervention, using both active and passive sampling techniques (seven days before and seven days after painting the rooms). Moreover, passive and active sampling was carried out simultaneously. Sampling. SKC BioSampler (the single-stage Anderson, model 200 Hole, e United States) with a BioLite air sampling pump were used for the active air sampling. However, the sampling pump was placed inside a bag fully in order to insulate sound effectively to ensure the well-being of the patients admitted in the rooms. In order to avoid any microbial contamination before the sampling, the BioSampler was completely disinfected using 70% ethanol according to the device catalog (catalog number: 9610-225) and then placed under a UV lamp [13] . During sampling, a 90 mm petri dishes containing the Sabouraud dextrose agar (SDA; Merk, Germany) medium supplemented with chloramphenicol (SC) was located in the BioSampler. e pump was set at a flow rate of 14.15 L/min for 10 minutes. e sampling circuit was done 150-120 cm away from the patient's respiratory tract and at a height of 150-100 cm from the floor. Petri dishes containing SC media were also used in the passive sampling method. During the sampling, the door of the plates was opened and placed at a height of 100-150 cm for 20 minutes [8] . After sampling, the door of petri dishes was completely closed with a paper glue to prevent the entry of secondary contamination and then transferred to the laboratory through a cold box. During the sampling, the door and windows of the room were always closed, and the personnel movements were prevented. e plates containing air samples were transferred to the laboratory and incubated for 3-7 days at 32°C. en, the fungal colonies were counted and identified according to morphological and microscopic characteristics. e SPSS 16 software, independent samples t-test, paired samples t-test, chi-square test, and Fisher's exact test were used in the preintervention and the postintervention assessment, in order to statistically prove the effect of nanosilver paint on the reduction of fungal contamination. In this study, 112 air samples (56 for each active and passive technique) were collected from the hematology ward. e results of active air sampling were reported as fungal colonyforming units (CFU)/m 3 , and the results of passive sampling were reported as CFU/plate. According to the results, both experimental and control rooms were contaminated by various fungal bioaerosols before intervention. However, there was not any significant difference between the air fungal load of the experimental and control rooms (P value � 0.237). e average numbers of fungal bioaerosols in experimental and control rooms were different after intervention (P value � 0.01). ese results reflect to low concentration of fungal agents per cubic meter of air in the control room after the intervention. e mean and standard deviation of the number of fungal agents as CFU/m 3 in the experimental room was 29.21 ± 17.99 before the intervention and 13.79 ± 6.20 after the intervention. is difference was significant with P value � 0.01 (Figure 1 ). On the other hand, the number of fungal agents per cubic meter of air was different before and after intervention in the experimental room. e mean and standard deviation of the number of fungal agents as CFU/m 3 in the control room was 22.50 ± 10.02 before intervention and 31.07 ± 21.1 after intervention. is difference was not significant with P value � 0.24 (Table 1) . e chi-square test and Fisher's exact test showed that the passive sampling data were often zero and one. e data analysis using these tests showed no significant difference between the preintervention stage (P value � 0.098) and the postintervention stage (P value � 1). is could indicate the major disadvantage of the passive sampling method compared to the active air sampling method for monitoring airborne fungal contamination. According to the results of room temperature measurement, the difference in temperature of the experimental and control rooms was not significant between the stages of preintervention (P value � 0.77) and postintervention (P value � 0.56). Moreover, the difference between the temperature of experimental room (P value � 0.57) and control room (P value � 0.05) was not significant before and after intervention. On the other hand, there was a similar temperature condition before and after intervention in both the experimental and control rooms ( Table 2 ). In addition, there was no significant difference between the humidity of rooms of the experimental and control rooms before (P value � 0.8) and after (P value � 0.92) intervention. e humidity difference between stages of preintervention and postintervention in the rooms of experimental (P value � 0.86) and control (P value � 0.53) was not significant either (Table 3 ). Indoor air of hospital wards could have a wide range of infectious microorganisms. Exposure to airborne microbes may have a more severe effect on susceptible groups, especially those who are immunocompromised [7] . Fungal agents are one of the most common microorganisms in hospital indoor environments, which can lead to nosocomial infections. e use of nanoparticles could be one of the ways that has been considered as a medical disinfectant in recent years [9] . In the current study, the use of the nanosilver paint was effective in reducing the air fungal contamination in an educational, research, and treatment center. According to the results, both the experimental and control rooms were contaminated by various fungal bioaerosols prior to the intervention. However, there was no significant difference between the fungal contamination load of the experimental and control rooms. e results also showed a significant difference in the fungal contamination between the preintervention and postintervention stages in the experimental room. Overall, these results indicate a reduction in the fungal contamination level in the experimental room air compared to the control room air. Jabbari et al. compared the average number of fungi colonies in the experimental and control rooms and showed a significant difference between them. ey showed the positive effect of nanosilver paint on reduction of air fungal pollution in hospitals [14] . However, Naddafi et al. showed that there is no significant difference between the average number of fungi colonies after use of nanosilver paint in rooms of experimental and control. Hence, their study did not indicate antimicrobial effectiveness of nanosilver paint to reduce the fungal contamination level in air [15] . According to Kaiser et al., the amount of nanosilver released from the painted surfaces over time is not so much as to give rise to toxic acute responses [16] . According to the results of Mueller and Nowak's study, the use of nanoparticles cause no adverse effects in the environment, and the concentration of silver nanoparticles in the environment is probably much lower than estimated values [17] . A very important point in interventional studies is that some possible factors can influence the actual outcome and its main objective. erefore, the impact of other interventional factors should be reduced as possible. Although the two similar studies mentioned above have been carried out in different times and places, since both studies have used nanoparticle paint, other important parameters should also be similar. One of the influential factors in these studies is the air sampling method. In the two previous studies, despite the similarity of the objectives, air sampling methods were different. Jabbari's study was carried out using the passive sampling method, and Naddafi's study was performed using the active sampling method [14, 15] . Several studies have compared the results of active and passive sampling methods, and contradictory results have been obtained. Some studies have shown a significant difference between the results of these two sampling methods, while the results of other studies have shown that there is no difference between the results of the two methods [18] . Sudharsanam's study showed a significant difference between the results of active and passive sampling methods [19] . Napoli et al. also achieved a similar result in his investigation and found that there was a severe difference between the results of them [18] . However, in the present study, the active and passive sampling methods were used simultaneously for the experimental and control rooms in order to eliminate or reduce the impact of the sampling method. In fact, in accordance with the standards of air sampling methods, the active sampling could show a real level of fungal contamination. Various studies conducted in the world on concentration of bioaerosols in hospitals proved that concentration of bioaerosols is different among various parts of a hospital as well as in different hospitals. For example, according to the [22] . erefore, it is necessary to reduce air fungal contamination load (AFCL) in various wards. On the other hand, according to the results of some studies, there is a significant relationship between the concentration of bioaerosols and environmental factors such as temperature and humidity [2, 5] . According to Bozic and Ilić' study, high humidity has greatly affected the concentration and growth of biological contaminants [23] . However, Jung et al. also showed that high temperature can have a negative effect on fungi [24] . For this reason, relative humidity and temperature of indoor air as interventional factors were examined in this study. According to the current results, there was no a significant difference in the temperature and humidity between the experimental and control rooms during the preintervention and postintervention stages. One of the limitations that can be mentioned in this plan includes the following: first, it was not possible to evaluate bacterial agents and was not examined in this regard. Second, the number of samples was limited, and if the number of samples was more, a stronger conclusion could be obtained. However, Naddafi et al. indicated that there was no statistically significant reduction in the bacterial agents between the control and case rooms and also between two types of paints by the active sampling method [15] . e results of the present study prove the effectiveness of paint containing silver nanoparticles in reducing airborne fungal contamination level in indoor air of hospitals. erefore, the use of this kind of paint can reduce the concentration of fungal bioaerosols, especially in hospital wards with susceptible patients. However, the number of samples was limited, and a large sample size could improve data analysis and obtain a stronger conclusion. CFU: Colony-forming units. e data used to support the findings of this study are available from the corresponding author upon request. is project obtained the code number IR. MUMS.-REC.1393.45 from Ethics Committee of Mashhad University of Medical Sciences. Not applicable. is work was derived a Master's thesis. e authors declare that they have no conflicts of interest. Comprehensive characterization of indoor airborne bacterial profile Bioaerosols in indoor environment-a review with special reference to residential and occupational locations Bio-aerosols in indoor environment: composition, health effects and analysis Assessment of airborne microflora in the academic institute of Dehradun Assessment of the levels of airborne bacteria, gram-negative bacteria, and fungi in hospital lobbies Airborne and surface-bound microbial contamination in two intensive care units of a medical center in central Taiwan First report of invasive Aspergillus rhinosinusitis in a critically ill COVID-19 patient affected by acute myeloid leukemia, northeastern Iran Assessment of indoor and outdoor airborne fungi in an educational, research and treatment center Silver nanoparticle applications and human health Evaluation and comparison of the effects of biosynthesized selenium and silver nanoparticles using plant extracts with antifungal drugs on the growth of Aspergillus and Candida species e effect of biosynthesized selenium nanoparticles on the expression of CYP51A and HSP90 antifungal resistance genes in Aspergillus fumigatus and Aspergillus flavus e silver nanoparticle (nano-Ag): a new model for antifungal agents Time effectiveness of ultraviolet C light (UVC) emitted by light emitting diodes (LEDs) in reducing stethoscope contamination Studying the effect of nanosilver painting on control of air-transmitted fungi Effect of nanosilver painting on control of hospital air-transmitted microorganisms Nanoparticles in paints: a new strategy to protect façades and surfaces? Exposure modeling of engineered nanoparticles in the environment Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres Characterization of indoor bioaerosols from a hospital ward in a tropical setting A study of air microbe levels in different areas of a hospital Assessment of airborne bacteria and fungi in an indoor and outdoor environment Evaluation of bioaerosols in five educational hospitals wards air in Hamedan Indoor air quality in the hospital: the influence of heating, ventilating and conditioning systems Treatment of fungal bioaerosols by a high-temperature, short-time process in a continuous-flow system