key: cord-0024639-u95whzz4 authors: Choi, Sooin; Choi, Soo Jeong; Kim, Jin Kuk; Nam, Ki Chang; Lee, Suehyun; Kim, Ju Han; Lee, You Kyoung title: Preliminary feasibility assessment of CDM-based active surveillance using current status of medical device data in medical records and OMOP-CDM date: 2021-12-15 journal: Sci Rep DOI: 10.1038/s41598-021-03332-6 sha: 834317beb21a767a4e5ac64c16617b64180fdeb9 doc_id: 24639 cord_uid: u95whzz4 In recent years, there has been an emerging interest in the use of claims and electronic health record (EHR) data for evaluation of medical device safety and effectiveness. In Korea, national insurance electronic data interchange (EDI) code has been used as a medical device data source for common data model (CDM). This study performed a preliminary feasibility assessment of CDM-based vigilance. A cross-sectional study of target medical device data in EHR and CDM was conducted. A total of 155 medical devices were finally enrolled, with 58.7% of them having EDI codes. Femoral head prosthesis was selected as a focus group. It was registered in our institute with 11 EDI codes. However, only three EDI codes were converted to systematized nomenclature of medicine clinical terms concept. EDI code was matched in one-to-many (up to 104) with unique device identifier (UDI), including devices classified as different global medical device nomenclature. The use of UDI rather than EDI code as a medical device data source is recommended. We hope that this study will share the current state of medical device data recorded in the EHR and contribute to the introduction of CDM-based medical device vigilance by selecting appropriate medical device data sources. www.nature.com/scientificreports/ In recent years, there has been an emerging interest in the use of claims and EHR data for evaluating medical device safety and effectiveness 10 . Attempts have been made to implement MDV active surveillance through a webbased platform for sharing the experiences on medical device incidents 11 and through a multicenter, prospective, observational research study 12 . However, both studies used a centralized method with patient data entered into the database as a common language agreed between network organizations. Studies of CDM-based MDV have not been reported yet. There is a difference between pharmacovigilance and medical device. Pharmacovigilance uses CDM to analyze adverse events associated with the use of a drug while medical device vigilance analyzes adverse events associated with the use of a medical device. This study was conducted to identify the current situation and derive improvements, assuming that medical device information deficiencies in EHR or CDM could become a hurdle for CDM-based MDVs. Soonchunhyang University Bucheon Hospital (SCHBC) in Bucheon, Gyeonggi Province, Republic of Korea is covered by Federated E-health Big Data for Evidence Renovation Network (FEEDER-NET) 13, 14 . According to the user manual provided by FEEDER-NET 15 , institutional unique prescription codes were used as medical device data sources and converted into electronic data interchange (EDI) codes used by national insurance claims in Korea. The EDI code is registered in Athena. It can be entered into the CDM as it is. However, since it is a nonstandard term, it is converted to the standard term, Systemized Nomenclature of Medicines-Clinical Terms (SNOMED-CT), and entered into the CDM if possible (Fig. 1) . Global Medical Device Nomenclature (GMDN) terms are the basis of SNOMED CT medical device content 16 . Analysis of medical device data recorded in EHR. Among the 2112 medical devices posted by the Ministry of Food and Drug Safety (MFDS), 433 posts had MDAE occurrence. Fifty-five medical devices were reported to have health effects on patients. Of the remaining 379 medical devices whose health effects were not reported, 101 had moderate or high potential risks. A total of 155 medical devices were finally enrolled to investigate medical device data in EHR (Fig. 2a) . Medical device information from SCHBC EHR was classified into four groups (Fig. 2b) . Ninety-one medical devices (91/155, 58.7%) were prescribed by code (EDI code linked) on online charting system (OCS) when used in patients. Fifty devices without other information recorded other than OCS prescriptions were classified into group 1. Forty-one medical devices (41/155, 26.5%) recorded as barcode data in the surgical nursing record on EMR were classified into group 2. Ten medical devices (10/155, 6.5%) recorded model name on picture archiving and communication system (PACS) were classified into group 3. Nine of them had model names displayed separately from the image without serial number or lot number. The other one, a gastroscope, had model name and serial number of the device displayed as part of the image. Fifty-four medical devices without direct device data were classified into group 4. Twenty-two of them did not have any records. Nineteen of them did not have a direct record. They were assumed to be used medical devices needed for treatment or surgeries. Thirteen had a number assigned by the user in the electronic medical record (EMR). However, they were considered as group 4 because such user given number had been assigned to a new device without any comments when replacing the device. Figure 3 shows changes of implanted medical device records in our institution. Prior to the introduction of EMR, OCS prescriptions using the National Insurance EDI code and scan images of barcode stickers for devices were recorded. Initially, the device name was interlinked with the OCS prescription and the barcode data was replaced by a keyboard entry lot number instead of a scan image. In 2019, barcode readers were introduced to improve barcode data recording. When the barcode is read, the entire barcode data and some distinguished data (lot or serial number and expiration date) are entered at a specified location. Focus analysis of medical device data. National insurance has 31 and 28 codes for metal and ceramic femoral heads, respectively. There were a total of 11 codes registered in our institute's OCS (Table 1) . On the Figure 1 . Current CDM mapping process of medical device data in Korea and scopes of this study. Among medical device data recorded in each medical institution's EHR, the institutional unique code recorded in the OCS is converted into a national insurance electronic data interchange (EDI) code. EDI codes are mapped using an OMOP CDM standard vocabulary. The standard vocabulary for medical device data is SNOMED. EHR electronic health records, CDM common data model, SCHBC Soonchunhyang University Bucheon Hospital, OCS online charting system, EDI electronic data interchange, EMR electronic medical record, PACS picture archiving and communication system, LIS laboratory information system, MDV medical device vigilance. www.nature.com/scientificreports/ CDM of SCHBC, three of those 11 femoral head codes were mapped to the standard concept of SNOMED-CT (code mapping was provided as Supplementary Table S1 ), while the other eight EDI terms were mapped to the non-standard concept of SNOMED-CT as shown in Fig. 4 . Both metal and ceramic femoral heads were used most frequently by Howmedica Osteonics Corp (Mahwah, NJ, USA). Thus, they were selected as focus groups: E1012001, E1012102, E1011031, and E1011231. E1011002 was not included as a focus group because it had a prescription record currently excluded from national insurance. Various medical device data sources used in this study provided different medical device classifications and data ( Table 2 ). The national insurance EDI code was commonly used by MOHW and MFDS data sources. Because EDI codes were applied without distinction to medical device specifications, the four EDI codes selected as focus groups were reclassified using the MFDS's medical device classification criteria. Models were available from the www.nature.com/scientificreports/ MFDS, the manufacturer's catalog, and Access Global Unique Device Identification Database (GUDID). EDI data were found from the MFDS and Access GUDID. There were 31 EDI codes registered as metal femoral head in national insurance (Fig. 5) . Each of 32 models registered under the E1012102 code was gaved a unique device identifier (UDI). The manufacturer's catalog categorized 32 models as Exter femoral head stainless steel and Orthinox V40 chemical head. The 32nd model (6364-2-628) of the E1012102 was registered with the MFDS as 07613327298239, but was not registered with the Access GUDID. The 81 models registered under the E1012001 code were categorized under five brand names depending on the type of taper (Morse, C and V40) and Low Friction Ion Treatment (LFIT) application. The first model to the 12th model were listed in the catalog as LFIT Morse taper head and Access GUDID as Morse head femoral head. By searching for Morse head femoral head in Access GUDID, 22 additional UDIs were identified that were not in the MFDS. They were classified under three brand names by the manufacturer. The 27th to 34th models were classified as C-Taper CoCr LFIT heads in the catalog, but were classified as C-Taper heads in Access GUDID. There were 30 EDI codes registered as ceramic femoral head in national insurance. The nine models registered with E1011031 code had a single brand name. Thirty-nine models were registered in E1011231, with six models (from 15th to 21st) being adapter sleeves, not femoral heads. The remaining 33 models were classified as three in the catalog and four brand names in the Access GUDID. Figure 6 presents ceramic femoral head hierarchies according to manufacturer, ceramic type, and head diameter. The 48 models registered in codes E1011031 and E1011231 were reclassified for the hierrarchies presented. MDV is currently performed through a variety of voluntary and mandatory reporting mechanisms to report events, not rates 17 . The calculation of the latter requires a denominator, that is, the total number of the used devices. For drugs, the situation is different. Sentinel Initiative monitors the safety and comparative effectiveness of drugs by leveraging national drug codes recorded at the point of care or the point of sale and transmitted to payers via insurance claims 18 . In Korea, the MFDS is required to record and preserve usage of some medical devices such as implanted medical devices for more than a year in order to track patients. However, medical institutions tend to write this as a dedicated document for medical management rather than recording it in EMR (personal communication). Mapping these data to an OMOP CDM is hard to expect. Therefore, national insurance EDI code has been used as a medical device data source in OMOP CDM (Fig. 1) , similar to the Sentinel Initiative. However, there has been no approach or feasibility assessment on whether CDM established by Korean institutions is suitable for MDV. Based on EHR record and OMOP CDM conversion status of medical device data, this study performed preliminary feasibility assessment of CDM-based MDV. • Adequacy of medical device EDI code for MDV purpose As of 2016, 97.1% of Korea's population are covered by national insurance. Health Insurance Review and Assessment Service (HIRA) has developed the EDI code system to classify and identify drugs, medical services, and devices. It also maintains the EDI code system. HIRA mandates the use of EDI vocabulary in the claim system. For this reason, every Korean EHR system uses the EDI vocabulary for most drugs, medical procedures, and devices. It has advantages as a data source in that it is structured and domestic standardized. However, EDI term has not been acknowledged as a standard vocabulary in the way that the Current Procedural Terminology, fourth edition has in the United States because its quality has never been audited 19 . Instead, there were several attempts to map the EDI term to SNOMED-CT [20] [21] [22] . Nevertheless, the EDI code as a medical device data source showed several limitations in the present study. First, only a few codes were mapped to standard terms (Table 1) . Second, it excluded non-claimed medical devices (groups 3 and 4 in Fig. 2a,b) . Third, medical devices might be unintentionally intermixed in a single EDI code even if all EDI codes are mapped to standard terms (Fig. 5 ). • Candidates for medical device data source other than EDI code EHR data capture is critical to device-tracking efforts 23 . For this purpose, the structure of the data and the presence of records on EHR are both important. EHRs are recorded as either unstructured keyboard entry narrative data or structured coded data 24 . Structured data enable the reuse of data collected in the course of clinical care. However, structured data systems are typically difficult to use, time consuming, and often inflexible for expressing complex clinical concepts. Previously reports have indicated that 80% of medical data are unstructured data while only 20% of medical data are structured data used mostly for disease diagnosis 25 . As shown in Fig. 2b , structured medical device data include prescription code modified national insurance EDI code (50 devices), barcode entry (41 devices) including UDI, and model (9 devices) recorded in PACS. Other medical devices without charging patients have been recorded in an unstructured form for management or not recorded. These unstructured data cannot be processed by algorithm directly. Additional data mining, natural language processing, and text analytics would be needed. In the Veteran Administration's Cardiovascular Assessment, Reporting, and Tracking (CART) initiative using free text and limited structured data entry, a dataset of questionable validity for surveillance efforts has been observed 26 . Tradeoffs between structured and unstructured data recording observed in Fig. 3 complicate the reuse of data. Which medical device data should be captured was discussed considering the existence of EHR records, the structure of the data, and the potential for standardization. The first option was brand name. It has advantages of easy verbal communication. However, it is not recorded in EHR. Considering the discrepancy in brand name recorded in the manufacturer's catalog and Access GUDID with only a few brand names registered in the MFDS ( www.nature.com/scientificreports/ names and record them in EHR. It was predicted that CDM conversion of brand name level might increase the loss of data integrity. In pharmacovigilance, brand name level CDM conversion showed 6 to 7% information loss to drug exposure 8, 9 . The second option was model (catalog number). The model is familiar to users as it is recorded in the catalog as well as in the MFDS. It gives specifications, enabling detailed classification of medical devices. The International Consortium of Orthopaedic Registries (ICOR) 27 is using models of devices for their identification. However, there has been no worldwide consensus on the encoding of part numbers 28 . Different prostheses have been identified with the same model and different models have been used for the same prosthesis. In addition, variations in models within and between different companies' products are possible. For example, in Fig. 5 , the LFIT Morse taper head is named 01-xxx. However, Morse taper femoral head is named S-1399-HHxx, although the two have the same manufacturer. Additional EHR records would be required to use www.nature.com/scientificreports/ the model because only 10 medical devices' model were recorded in our EHR (Fig. 2a, group 3) . The last option was UDI. UDI includes device identifier (UDI-DI) and production identifier (UDI-PI). The UDI-DI should be globally unique 29 . It should identify the specific version or model of a device and its manufacturer. The UDI-PI identifies one or more of the following when present on the label of the device: the lot or batch within which a device was manufactured, the serial number, the expiration date, and the date on which a specific device was manufactured 30 . Manufacturers must label medical devices with UDI code in a machine-readable format, such as a barcode, radiofrequency identifier (RFID), and human-readable text. The United States Food and Drug Administration (FDA) released a proposed rule in July 2012 that medical devices distributed in the US should be fitted with UDI 31 . Manufacturers must submit key product to GUDID that can be accessed by both patients and providers 32 . The European Union (EU) medical device regulations also require fitting of UDI to all medical 34 . In Korea, mandatory UDI attachment was implemented by the MFDS in July 2019. All medical devices should have UDI attachment by 2022. To efficiently manage them, an integrated information system for medical device is also in operation 35 . Although it is introduced after 2019, UDI is recorded in the EHR as a barcode entry in our institute (Fig. 3) . It can be easily structured as it is generated in accordance with regulations. Therefore, the authors determine that UDI is the most appropriate medical device data source to be mapped to CDM. Health systems may benefit from UDI adoption for several reasons other than postmarket surveillance. The UDI establishes a standard identifier to track the device that can be captured by barcode scanning already widely used for many purposes 36 . Scanning this single UDI barcode is easier than individually capturing several fields, such as manufacturer, product type, and serial number. It can improve inventory management systems to monitor inventory, enable automatic reordering, and ensure that devices are used before their shelf life expires 37 . Moreover, knowledge of a patient's implanted devices or those used previously can improve clinical care. If issues are identified or the device is recalled, they could be notified quickly 38 . As with barcode e-MAR (electronic drug administration records), which significantly reduces medication errors, barcode scanning in medical devices can improve patient safety 39 . For UDI adaption, hospitals need to upgrade their EHR and supply-chain management programs to capture UDIs and train staff. Although some large health care systems have successfully implemented UDI for implantable devices 26 , UDI has had limited effect because it is available in neither EHR nor claims 38 . The Office of the National Coordinator for Health Information Technology has ruled that EHRs must have the capability to record UDIs to receive certification. However, this capability is not mandatory 18 . Requiring the UDI in claims is expected to prompt EHR integration 32 . It has the potential to greatly enhance postmarket surveillance and provide essential data for performing research using real-world evidence. CMS has previously expressed concern about such a requirement because the cost and complexity of changing operating and technical systems to include the UDI in claims. The current proposal shortens claims requirement to include only UDI-DI, meaning that specific models could be identified if UDI-PI is not be available. A partial implementation that uses only UDI-DI could decrease the utility of the UDI because important information about a faulty device's production may be missing 38 . Additionally, even if all providers modify their EHR related to claims and if payers modify their claims-processing systems to accept UDIs, MDV system will not automatically emerge. In the MDV system, some unique characteristics of medical devices should be considered 40 . Medical devices consist of multiple components with complex interactions among devices. The effect of device-specific learning 41 and differences in experience between providers can influence clinical outcomes 42 . Mechanical failure, even software error, could be a potential cause of failure. None of these issues is usually a problem with drugs 7,43,44 . A functioning medical device evaluation system would be needed. Although UDI can make unique identification of medical device possible 45 , it is only useful for identifying an issue with a specific device from one manufacturer. Generic device grouping of UDI would enable systematic problem to be identified early. Global Medical Device Nomenclature (GMDN) code fulfils requirements of a generic device group 46 . The GMDN is a list of generic. It was specified as the naming convention for the device portion of the UDI by FDA. The Preferred Term in GMDN is the valid description of a group of devices. It does not differentiate between device models or those from different manufacturers with the same intended use and technology. Therefore, GMDN system enables early identification of a systematic problem not limited to one manufacturer, but shared by other products that use the same technology or materials. In SNOMED-CT system, the only medical device standard vocabulary considered in OMOP CDM, the concept of device is mapped to a subset of GMDN codes. However, various analyses were considered difficult with stratification of SNOMED-CT. Work to expand the GMDN content in SNOMED-CT is required to satisfy wider purposes of SNOMED-CT linked to the use of medical devices. To support its further development, developing medical device descriptions in clinical terminology, linking to additional clinical data, and adding more layers of more specific medical device terms would be needed 16 . For example, the authors identified two EDI codes from ceramic femoral heads www.nature.com/scientificreports/ www.nature.com/scientificreports/ as examples of UDI for medical devices and sub-grouped them into materials, manufacturers, and specifications based on opinions of orthopedic experts (Fig. 6) . This study has several limitations. First, since a single institution status was investigated, the situation might be different for other countries or institutions. Second, only representative devices in each medical device category were analyzed. Therefore, the EHR recording status for devices not directly identified might differ from this study, even if they are included in the target medical device category. OMOP CDM, which is built in our institution, uses EDI code as a medical device data source. Despite its advantages of structural and standardization, EDI is matched in one-to-many with UDI, including devices classified as different GMDNs. Therefore, it is difficult to ensure the accuracy of surveillance results if all medical devices corresponding to a single EDI code are considered to have a single characteristic. To communicate safety information of medical devices, it is recommended to use internationally accepted UDI rather than EDI code as a data source. To introduce UDI, each institution needs to have a barcode reader, develop EHR, and train users. To compensate for the vulnerability of UDI to systematic problem identification, analysis of generic device groups using GMDN is necessary. In this respect, SNOMED-CT that reflects GMDN is appropriate for CDM-based MDVs. However, since analysis according to various device characteristics is difficult with current classification, adding more specific layers is essential. Finally, even if UDI is recorded in EHR and converted to CDM, additional MDV systems are needed to analyze it. Figure 6 . Ceramic femoral head hierrarchy was applied to Stryker's products registered with national insurance EDI codes E1011031 and E1011231. EDI electronic data interchange, SNOMED systematized nomenclature of medicine clinical terms, UDI unique device identifier, DI device identifier. To evaluate the adequacy of EDI for MDV purposes and to determine the existence of medical device data other than EDI, the target medical device was selected and medical device records of EHR were grouped. Selection of target medical devices: According to the Ministry of Food and Drug Safety (MFDS) notice in May 2020, medical devices in Republic of Korea are classified into 2112 categories. The following three criteria were applied to select medical devices to evaluate the frequency of MDAE and their risk to patients: According to data format, data were classified as unstructured narrative text and structured coded data 47 . The number and percentage of medical devices corresponding to each information level and data formet were obtained. Microsoft Excel 2019 (Microsoft, Redmond, WA, USA) was used for statistical processing. Focus analysis of medical device data. To provide a detailed example of medical device data, focus group analysis was conducted using single item: femoral head. Medical device data related to the focus group were retrieved and collected from the MOHW's medical device price list notice 48 , the MFDS's Information Portal 49 , and the U.S. national library of medicine's Access GUDID 50 . To analyze SNOMED-CT conversion status of medical device data, Observational Health Data Sciences and Informatics (OHDSI) open-source software and OMOP CDM version 5.3 database were used. EHR of SCHBC was converted to source name of cdmpv531_0920_bucheon. Central vocabulary service Athena (http:// athena. ohdsi. org) was used to assess the hierarchy of SNOMED-CT. Bucheon Hospital (SCHBC) (approval number: SCHBC 2020-08-028-001). Consent to participate. Informed consent was waived by the IRB. Data are available from the corresponding author upon reasonable request. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead Semper fidelis-Consumer protection for patients with implanted medical devices Differences in perspectives of medical device adverse events: Observational results in training program using virtual cases Part I: Identifying holes in the safety net Postmarketing surveillance of medical devices-Filling in the gaps Post-marketing device safety surveillance Postmarket surveillance for medical devices: America's new strategy ADEpedia-on-OHDSI: A next generation pharmacovigilance signal detection platform using the OHDSI common data model An evaluation of the THIN database in the OMOP common data model for active drug safety surveillance Real-world evidence and real-world data for evaluating drug safety and effectiveness Web-based experience sharing platform on medical device incidents for clinical engineers in hospitals An evaluation of a distributed medical device safety surveillance system: The DELTA network study Deep phenotyping of 34,128 adult patients hospitalised with COVID-19 in an international network study The distributied research network, observational health data sciences and informatics, and the South Korea research network Current state of medical device nomenclature and taxonomy systems in the UK: Spotlight on GMDN and SNOMED CT The need for greater reporting of medical device incidents Transmitting device identifiers of implants from the point of care to insurers: A demonstration project Incorporation of Korean Electronic data interchange vocabulary into observational medical outcomes partnership vocabulary Mapping Korean EDI medical procedure code to SNOMED CT Conversion of national health insurance service-national sample cohort (NHIS-NSC) database into observational medical outcomes partnership-common data model (OMOP-CDM) Permanente national total joint replacement registry: Aligning operations with information technology Data from clinical notes: A perspective on the tension between structure and flexible documentation A review on unstructured data in medical data Implementing unique device identification in electronic health record systems: Organizational, workflow, and technological challenges The international consortium of orthopaedic registries: Overview and summary Challenges in prosthesis classification Unique Device Identification (UDI) of Medical Devices New FDA medical device rule imposes minimal burden on hospitals: Facilities able to scan unique device identifiers will benefit Unique device identification in the service of public health The value of unique device identifiers in plastic surgery New European medical device regulation: How the French ecosystem should seize the opportunity of the EUDAMED and the UDI system, while overcoming the constraints thereof New medical device regulations: The regulator's view. EFORT Open Rev Ministry of Food and Drug Safety. Medical devices act Value of unique device identification in the digital health infrastructure The Mercy unique device identifier demonstration project: Implementing point of use product identification in the cardiac catheterization laboratories of a regional health system Fulfilling the promise of unique device identifiers Effect of bar-code technology on the safety of medication administration On the complexity of medical devices and systems Quantifying the learning curve in the use of a novel vascular closure device: an analysis of the NCDR (National Cardiovascular Data Registry) CathPCI registry The data extraction and longitudinal trend analysis network study of distributed automated postmarket cardiovascular device safety surveillance Recalls and safety alerts affecting automated external defibrillators The rosiglitazone story-Lessons from an FDA Advisory Committee meeting Augmenting medical device evaluation using a reusable unique device identifier interoperability solution based on the OHDSI common data model Global medical device nomenclature: The concept for reducing device-related medical errors Definition, structure, content, use and impacts of electronic health records: A review of the research literature ? pgmid= HIRAA 03006 90004 00& brdSc nBltNo= 4& brdBl tNo= 51884 & isPop upYn=Y Ministry of Food and Drug Safety /scientificreports/ Correspondence and requests for materials should be addressed to The authors declare no competing interests. Supplementary Information The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-021-03332-6.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.