key: cord-0024199-59363xzp authors: Lin, Xiaofeng; Mei, Yanqiu; He, Chen; Luo, Yan; Yang, Min; Kuang, Ying; Ma, Xiaoming; Zhang, Huifang; Huang, Qitong title: Electrochemical Biosensing Interface Based on Carbon Dots-Fe(3)O(4) Nanomaterial for the Determination of Escherichia coli O157:H7 date: 2021-11-19 journal: Front Chem DOI: 10.3389/fchem.2021.769648 sha: 02cb31af4877e7bf4960116a573cae3cf2881e16 doc_id: 24199 cord_uid: 59363xzp Escherichia coli (E. coli) O157:H7 can cause many food safety incidents, which seriously affect human health and economic development. Therefore, the sensitive, accurate, and rapid determination of E. coli O157:H7 is of great significance for preventing the outbreak and spread of foodborne diseases. In this study, a carbon dots-Fe(3)O(4) nanomaterial (CDs-Fe(3)O(4))-based sensitive electrochemical biosensor for E. coli O157:H7 detection was developed. The CDs have good electrical conductivity, and the surface of carbon dots contains abundant carboxyl groups, which can be used to immobilize probe DNA. Meanwhile, the CDs can be used as a reducing agent to prepare CDs-Fe(3)O(4) nanomaterial. The Fe(3)O(4) nanomaterial can improve the performance of the electrochemical biosensor; it also can realize the recovery of CDs-Fe(3)O(4) due to its magnetism. As expected, the electrochemical biosensor has excellent specificity of E. coli O157:H7 among other bacteria. The electrochemical biosensor also exhibited good performance for detecting E. coli O157:H7 with the detection range of 10–10(8) CFU/ml, and the detection limit of this electrochemical biosensor was 6.88 CFU/ml (3S/N). Furthermore, this electrochemical biosensor was successfully used for monitoring E. coli O157:H7 in milk and water samples, indicating that this electrochemical biosensor has good application prospect. More importantly, this research can provide a new idea for the detection of other bacteria and viruses. In recent years, food poisoning caused by foodborne pathogens has frequently occurred worldwide, which is the most prominent public health problem in the world (Hou et al., 2020; Duan et al., 2021) . As one of the most hazardous foodborne pathogens, Escherichia coli (E. coli) O157:H7 can cause some diseases such as hemorrhagic colitis and hemolytic uremic syndrome. What is more, low-dose E. coli O157:H7 can make humans sick, and in severe cases, it can even cause kidney failure and death. Currently, more than two million acute foodborne diseases worldwide are attributed to E. coli O157:H7 each year (Li et al., 2015a; Zhou et al., 2020) . Therefore, it is very important to monitor the E. coli O157:H7 with high sensitivity. At present, some bioanalytical methods have been applied for E. coli O157: H7 detection, including enzyme-linked immunosorbent assay (ELISA) (Guo et al., 2016; Zhao et al., 2020) , lateral flow immunochromatographic detection technology (Xie et al., 2014; Ye et al., 2020) , polymerase chain reaction (PCR) (Dong et al., 2015) , and so on. These alternative assays are the most rapidly used tests because of their good specificity and stability. Nevertheless, they are still faced with some limitations in detecting foodborne pathogens, including low sensitivity, complicated pretreatment, and high environmental impact. Therefore, there is an urgent need to establish a sensitive, simple, and highly specific method for detecting E. coli O157: H7. At present, many different electrochemical sensors have been used in food safety due to their some advantages, such as high sensitivity, economy, and accuracy (Li et al., 2015b; Li et al., 2016; Dong et al., 2020) . Therefore, electrochemical biosensors for the detection of E. coli O157:H7 have received extensive attention. As is known, due to the excellent chemical, physical and biological properties of nanomaterials, they have been widely used in biomedical Kuang et al., 2020; Thakur et al., 2020; Wu et al., 2020; Yi et al., 2021) , analytical science (Chen et al., 2018; Broza et al., 2019; Jia et al., 2020; Lee et al., 2020; Mao et al., 2020; He S. et al., 2021; Mao et al., 2021) , energy catalytic (Zhuang et al., 2019a; Zhuang et al., 2019b; Enesca, 2020; Zhuang et al., 2021) , and other fields. Till now, some nanomaterials have been successfully used to construct electrochemical sensors for E. coli O157:H7 detection, such as graphene/AuNPs (You et al., 2020) , reduced graphene oxide/polyaniline/Au@Pt/neutral red (rGO/PANI/Au@Pt/Nr) (Mo et al., 2019) , rGO/Au@Pt (Zhu et al., 2018) , rGO-poly (vinyl alcohol)/gold nanoparticles nanocomposite (AuNPs/rGO-PVA) (Qaanei et al., 2021) , and so on. Although the abovementioned materials have made certain contributions to electrochemical sensors for detecting E. coli O157: H7, the abovementioned materials still have disadvantages, including complicated preparation, insufficient economy, and environmental protection, or low sensitivity of sensors. Therefore, it is important to prepare an easy-to-obtain, economical, and environmentally friendly functional material for the construction of electrochemical sensors for detecting E. coli O157:H7. As a member of "zero-dimensional" carbon nanomaterials, carbon dots (CDs) have some advantages of good biocompatibility, simple synthesis, and excellent conductivity (Zhang et al., 2019; Huang et al., 2020; Zhang and Du, 2020; He H. et al., 2021; Lin et al., 2021; Xu and Liu, 2021) , and they have been successfully used to construct new electrochemical sensors, such as Pd-Au@CDs nanocomposite that we prepared for the preparation of the novel electrochemical DNA biosensor (Huang et al., 2017) . Liu et al. designed an electrochemical sensor for measuring catechol based on F, N-doped CDs (Liu et al., 2019) . Giang et al. constructed a wireless electrochemical biosensor based on CDs-hyaluronic acid/TiO 2 /Cu 2+ for cancer cell detection (Giang et al., 2021) . Sri et al. developed a CD/polymethyl methacrylate-based electrochemical biosensor for monitoring TNF-α targeting (Sri et al., 2021) . In this study, a CDs-Fe 3 O 4 nanomaterial-based electrochemical biosensor is constructed for detecting E. coli O157:H7, which is highly sensitive and reliable ( Figure 1 ). The CDs have good electrical conductivity and large specific surface areas to improve the sensitivity of the sensor. The CDs also can be used as the reducing agent to synthesize the CDs-Fe 3 O 4 nanomaterial. The Fe 3 O 4 can improve the catalytic performance of the electrochemical biosensor, and it also can realize the recovery of CDs-Fe 3 O 4 due to its magnetism. This electrochemical biosensor can achieve a good linear and detection limit for monitoring E. coli O157:H7. In addition, the biosensor has been also successfully applied to measure the E. coli O157:H7 in milk, indicating that the electrochemical biosensor has a broad application prospect. What is more, this study can provide a new idea for the preparation of electrochemical biosensors for other bacteria and virus detection, such as Staphylococcus aureus (S. aureus), Listeria, SARS-CoV-2, Hepatitis B virus, etc. The preparation of CDs-Fe 3 O 4 nanocomposite was based on the method of instrument preparation of our group (Kuang et al., 2020) : First, 3 g of citric acid and 1 g of glucose were added in 5 ml H 2 O and reacted under microwave with a radiation power of 900 W for 6 min to synthesize CDs. Second, the above solution was cooled and added 30 ml H 2 O, centrifuged them at 12,000 rpm for 15 min and took the supernatant, then dialyzed the supernatant for 24 h and then freeze dried. Third, the abovementioned CD solid was dissolved in 25 ml of the aqueous solution, then 1 g of sodium acetate and 1 g of ferric chloride was added into 15 ml of CD solution, the mixed solution was sonicated for 8 h, then placed in an autoclave, and reacted at 210°C for 24 h; after cooling, they were centrifuged at 12,000 rpm for 10 min to acquire CDs-Fe 3 O 4 nanomaterial. First, 5.0 μl of CDs-Fe 3 O 4 nanomaterial was slowly dropped on the glassy surface of the carbon electrode (GCE) to prepare a CDs-Fe 3 O 4 /GCE working electrode. Second, the CDs-Fe 3 O 4 / GCE electrode was immersed in 1 ml of 0.1 mM PBS, 8.00 mM EDC, and 8.00 mM NHS mixed solution for 3 h to activate the electrode, then it was rinsed with TE buffer solution. Third, the above electrode was immersed in 1 ml of 0.1 μM probe DNA to react for 24 h, and it was rinsed with TE buffer solution to prepare the DNA/CDs-Fe 3 O 4 /GCE probe electrode. Finally, the prepared electrode was stored at 4°C. The prepared DNA/CDs-Fe 3 O 4 /GCE was immersed into different concentrations (C) of E. coli O157:H7 solutions and reacted for 40 min at 42°C in a water bath. After the reaction, TE buffer solution was used to wash off non-specifically adsorbed Frontiers in Chemistry | www.frontiersin.org November 2021 | Volume 9 | Article 769648 E. coli on the surface to obtain the E. coli O157:H7-DNA/CDs-Fe 3 O 4 /GCE. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) have characterized the layer-by-layer assembly of each modified electrode: the [Fe (CN) 6 ] 3-/4has been applied as the electrolyte. For the test parameters of CV, the potential scanning range was −0.2-0.8 V, and the scan rate(5) was 0.1 V/s. DPV was used to record the electrochemical signal changes before and after the identification of the electrode and different substances, and the potential interval was −0.2-0.8 V, the amplitude was 0.05 V, the pulse width was 0.05 s. Transmission electron microscopy (TEM) has characterized the morphologies of CDs and CDs-Fe 3 O 4 nanomaterial. As shown in Figure 2A , the particle size distribution of the prepared CDs is relatively uniform, mainly at 3-4 nm. Figure 2B shows the highresolution TEM (HRTEM) image of CDs. It shows that CDs have a good crystal lattice, and the lattice spacing is 0.210 nm, which is a typical (002) carbon crystal plane. As shown in Figure 2C , the particle size of the CDs-Fe 3 O 4 nanomaterial was in the range of 15-40 nm. The HRTEM characterization of CDs-Fe 3 O 4 ( Figure 2D ) shows that the nanomaterial has two lattice spacings, 0.345 and 0.210 nm, respectively. The corresponding crystal planes are (220) of the Fe 3 O 4 and (002) of the carbon. The above morphology characterization can indicate that CDs-Fe 3 O 4 nanomaterial has been successfully prepared. It is well known that [Fe(CN) 6 ] 3−/4− is often used as a supporting electrolyte for electrochemical biosensors (Fan et al., 2018; Li et al., 2021; Nano et al., 2021) . The working electrodes were electrochemically characterized by CVs in 1.0 mM [Fe(CN) 6 ] 3−/4− and 0.1 M KCl solution ( Figure 3A) . On the surface of GCE, the Frontiers in Chemistry | www.frontiersin.org November 2021 | Volume 9 | Article 769648 redox peak current (I) has good reversibility, and the oxidation peak potential (I pa ) and reduction peak potential (I pc ) are −6. The effect of different v on the electrochemical response of DNA/ CDs-Fe 3 O 4 /GCE in [Fe(CN) 6 ] 3−/4− has also been studied. Figure 4A shows that in the process of increasing v, the I also keeps increasing. As shown in Figure 4B , the I pa and I pc show an excellent linear relationship with ] 1/2 , and the linear regression equations are I pa 3.598 + 80.265 v 1/2 and I pa −2.551-85.187 v 1/2 , respectively. The results show that the electrochemical behavior of [Fe(CN) 6 ] 3−/4− on the surface of DNA/CDs-Fe 3 O 4 /GCE is mainly affected by the diffusion-controlled process (Alam and Deen, 2020) . The interaction time between the probe electrode and the target substance is one of the key factors affecting the performance of the biosensors. Therefore, the interaction time of E. coli O157:H7 with DNA/CDs-Fe 3 O 4 /GCE was studied. When the C of E. coli O157:H7 was 10 CFU/Ml, the optimum hybridization time was determined to be 40 min (Supplementary Figure S1) . However, when the C of E. coli O157:H7 was 10 8 CFU/Ml, the optimum hybridization time was determined to be 35 min (Supplementary Figure S2) . Therefore, in this electrochemical biosensor, the best reaction time between E. coli O157:H7 and DNA/CDs-Fe 3 O 4 / GCE is 40 min. The specificity of the electrochemical biosensor is a necessary factor to ensure the accuracy of the biosensor. Therefore, the interferences of different bacteria with 10 5 CFU/ml on the DNA/ CDs-Fe 3 O 4 /GCE through DPV have been investigated, such as S. aureus, Salmonella, Staphylococcus lactis (S. lactis), and Listeria. Figure 5A shows that DNA/CDs-Fe 3 O 4 /GCE has almost no effect on other bacteria. However, the DNA/CDs-Fe 3 O 4 /GCE has a very strong response to E. coli O157:H7, and the I pa drops by 53.42%. As shown in Figure 5B , other interfering substances have almost no effect on the determination of E. coli O157:H7. The above results show that the electrochemical biosensor based on DNA/CDs-Fe 3 O 4 /GCE for detecting E. coli O157:H7 has very excellent specificity and is expected to realize the determination of E. coli O157:H7 in real samples. As is known, DPV has been extensively applied in the construction of electrochemical sensors because it has good detection sensitivity. This study explores the sensitivity and Figure 6A shows that when E. coli O157:H7 interacts with DNA/CDs-Fe 3 O 4 /GCE, I pa decreases as the C of E. coli O157: H7 increases. The main possible reason is E. coli O157:H7 has poor electrical conductivity, which affects the electrical conductivity of the working electrode's interface, leading to a weakening of the electrochemical signal. When the C of E. coli O157:H7 is in the range of 10-107 CFU/ml, the lgC and I pa show a good linear relationship ( Figure 6B ): I pa 1.5422 lgC-14.387. At the same time, the detection limit (LOD) can reach 6.88 CFU/ ml. Compared with other electrochemical biosensors for monitoring E. coli O157:H7 (Table 1) , this electrochemical biosensor based on DNA/CDs-Fe 3 O 4 /GCE has very good sensitivity. To investigate the reproducibility of this biosensor, six DNA/ CDs-Fe 3 O 4 /GCE working electrodes were prepared, and they have been applied to detect 10 5 CFU/ml of E. coli O157:H7 respectively. Supplementary Figure S3 shows that the relative standard deviation (RSD) was 2.6%, which indicates the electrochemical biosensor based on DNA/ CDs-Fe 3 O 4 /GCE for E. coli O157:H7 detection has good reproducibility. The stability of the electrochemical biosensor has been also studied; the DNA/CDs-Fe 3 O 4 /GCE was placed in a dryer at 4°C, and the above working electrode was applied to measure 10 5 CFU/ml of E. coli O157:H7 every 3 days. As shown in Supplementary Figure S4 after 30 days, the I pa was only dropped by 2.7%, which shows that the electrochemical biosensor based on DNA/CDs-Fe 3 O 4 /GCE has good stability. Since milk and water are often contaminated by E. coli O157:H7, it is very necessary to efficiently determine E. coli O157:H7 in milk and water. In this study, to verify the practical applicability of the biosensor, the electrochemical biosensor is used to determine the E. coli O157:H7 in milk and water. Frontiers in Chemistry | www.frontiersin.org November 2021 | Volume 9 | Article 769648 shows that 10 3 , 10 4 , and 10 5 CFU/ml of E. coli O157:H7 were added to the samples, and the recovery rates are between 95.2% and 102.0%, At the same time, the results were consistent with ELISA results, indicating that the method is feasible for monitoring E. coli O157:H7 in milk and water samples. In conclusion, a sensitive electrochemical DNA biosensor has been prepared for monitoring E. coli O157:H7 by CDs-Fe 3 O 4 nanomaterial. Under the best conditions, when the C of E. coli O157:H7 is in the range of 10-10 8 CFU/ml, the lgC has a good linear relationship with the I pa , and the LOD reaches 6.88 CFU/ml. At the same time, the electrochemical DNA biosensor has been successfully used to determine E. coli O157:H7 in milk and water samples. Therefore, this research provides an effective biosensor manufacturing strategy, which is expected to provide a reference for the preparation of electrochemical DNA biosensors for other bacteria or viruses detection. 9.96 × 10 3 99.6 9.53 × 10 3 10 5 1.02 × 10 5 102.0 9.91 × 10 4 Water 10 3 9.93 × 10 2 99.3 9.86 × 10 2 10 4 9.89 × 10 3 98.9 9.81 × 10 3 10 5 9.79 × 10 4 97.9 9.69 × 10 4 Frontiers in Chemistry | www.frontiersin.org November 2021 | Volume 9 | Article 769648 Bisphenol A Electrochemical Sensor Using Graphene Oxide and β-Cyclodextrin-Functionalized Multi-Walled Carbon Nanotubes An Electrochemical Aptasensor Based on Cocoon-Like DNA Nanostructure Signal Amplification for the Detection of Escherichia C O157:H7 Disease Detection with Molecular Biomarkers: From Chemistry of Body Fluids to Nature-Inspired Chemical Sensors An Electrochemical Biosensor Based on Methylene Blue-Loaded Nanocomposites as Signal-Amplifying Tags to Detect Pathogenic Bacteria Graphitic Porous Carbon: Efficient Synthesis by a Combustion Method and Application as a Highly Selective Biosensor Development of Droplet Digital Polymerase Chain Reaction for Quantifying Escherichia Coli O157: H7. Chin Low-Dimension Nanomaterial-Based Sensing Matrices for Antibiotics Detection: A Mini Review A Methylene Blue Assisted Electrochemical Sensor for Determination of Drug Resistance of Escherichia C Enhancing the Photocatalytic Activity of SnO2-TiO2 and ZnO-TiO2 Tandem Structures toward Indoor Air Decontamination Rolling Circle Amplification Triggered Poly Adenine-Gold Nanoparticles Production for Label-Free Electrochemical Detection of Thrombin Cancer Cells Targeted Visible Light and Alkaline Phosphatase-Responsive TiO2/Cu2+ Carbon Dots-Coated Wireless Electrochemical Biosensor DNA-Based Hybridization Chain Reaction and Biotin-Streptavidin Signal Amplification for Sensitive Detection of Escherichia C O157:H7 through ELISA Nanoplatform Based on GSH-Responsive Mesoporous Silica Nanoparticles for Cancer Therapy and Mitochondrial Targeted Imaging Magnetic Beads-Based Multicolor Colorimetric Immunoassay for Ultrasensitive Detection of Aflatoxin B1 Rapid Detection of Bifidobacterium Bifidum in Feces Sample by Highly Sensitive Quartz Crystal Microbalance Immunosensor Pd-Au@carbon Dots Nanocomposite: Facile Synthesis and Application as an Ultrasensitive Electrochemical Biosensor for Determination of Colitoxin DNA in Human Serum Graphene Quantum Dots/ Multiwalled Carbon Nanotubes Composite-Based Electrochemical Sensor for Detecting Dopamine Release from Living Cells Interface Design of SnO2@PANI Nanotube with Enhanced Sensing Performance for Ammonia Detection at Room Temperature A Novel Nanosystem Realizing Curcumin Delivery Based on Fe3O4@Carbon Dots Nanocomposite for Alzheimer's Disease Therapy Multiaxially-Stretchable Kirigami-Patterned Mesh Design for Graphene Sensor Devices Electrochemical Impedance Immunosensor Based on Self-Assembled Monolayers for Rapid Detection of Escherichia C O157:H7 with Signal Amplification Using Lectin The Art of Signal Transforming: Electrodes and Their Smart Applications in Electrochemical Sensing A Portable Electrochemical Immunosensor for Rapid Detection of Trace Aflatoxin B1 in rice A Sensitive Electrochemical Strategy via Multiple Amplification Reactions for the Detection of E. C O157: H7 Novel Cells-Based Electrochemical Sensor for Investigating the Interactions of Cancer Cells with Molecules and Screening Multitarget Anticancer Drugs Carbon Dots Based on Natural Resources: Synthesis and Applications in Sensors Electrochemical Sensor Based on F,N-Doped Carbon Dots Decorated Laccase for Detection of Catechol Tumor Microenvironment-Responsive Nanomaterials as Targeted Delivery Carriers for Photodynamic Anticancer Therapy Preparation of a Sensor Based on Biomass Porous Carbon/Covalent-Organic Frame Composites for Pesticide Residues Detection Analysis of Organophosphorus and Pyrethroid Pesticides in Organic and Conventional Vegetables Using QuEChERS Combined with Dispersive Liquid-Liquid Microextraction Based on the Solidification of Floating Organic Droplet Dispersive Solid-Phase Extraction Using Microporous Metal-Organic Framework UiO-66: Improving the Matrix Compounds Removal for Assaying Pesticide Residues in Organic and Conventional Vegetables A Sensitive and Regenerative Electrochemical Immunosensor for Quantitative Detection of Escherichia C O157:H7 Based on Stable Polyaniline Coated Screen-Printed Carbon Electrode and rGO-NR-Au@Pt DNA Electrochemistry: Charge-Transport Pathways through DNA Films on Gold Electrochemical Aptasensor for Escherichia coli O157:H7 Bacteria Detection Using a Nanocomposite of Reduced Graphene Oxide, Gold Nanoparticles and Polyvinyl Alcohol Simple and Facile Carbon Dots Based Electrochemical Biosensor for TNF-α Targeting in Cancer Patient's Sample Frontiers in Chemistry | www.frontiersin.org Nanoparticles as Smart Carriers for Enhanced Cancer Immunotherapy Recent Advances in Photodynamic Therapy Based on Emerging Two-Dimensional Layered Nanomaterials Advantages of Fluorescent Microspheres Compared with Colloidal Gold as a Label in Immunochromatographic Lateral Flow Assays The Behavior of Carbonized Polymer Dots at the Nano-Bio Interface and Their Luminescent Mechanism: A Physical Chemistry Perspective Development of a Combined Immunochromatographic Lateral Flow Assay for Accurate and Rapid Escherichia C O157:H7 Detection A Step-by-Step Multiple Stimuli-Responsive Metal-Phenolic Network Prodrug Nanoparticles for Chemotherapy Laser-Induced Noble Metal Nanoparticle-Graphene Composites Enabled Flexible Biosensor for Pathogen Detection Electrochemical Sensors Based on Carbon Nanomaterial Used in Diagnosing Metabolic Disease Red/Orange Dual-Emissive Carbon Dots for pH Sensing and Cell Imaging Rapid and Accurate Detection of Escherichia C O157:H7 in Beef Using Microfluidic Wax-Printed Paper-Based ELISA Gold Nanobones Enhanced Ultrasensitive Surface-Enhanced Raman Scattering Aptasensor for Detecting Escherichia C O157 A Non-Enzymatic Electrochemical Immunoassay for Quantitative Detection of Escherichia coli O157:H7 Using Au@Pt and Graphene The Holy Grail in Platinum-Free Electrocatalytic Hydrogen Evolution: Molybdenum-Based Catalysts and Recent Advances Sisyphus Effects in Hydrogen Electrochemistry on Metal Silicides Enabled by Atomically Dispersed Nonmagnetic Electron Traps Improve Oxygen Reduction Activity of Perovskite Oxides The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.