key: cord-0022560-89dmmbxh authors: Chi, Yi; Zhang, Qing; Yuan, Siyi; Zhao, Zhanqi; Long, Yun; He, Huaiwu title: Twenty-four-hour mechanical power variation rate is associated with mortality among critically ill patients with acute respiratory failure: a retrospective cohort study date: 2021-10-25 journal: BMC Pulm Med DOI: 10.1186/s12890-021-01691-4 sha: a01ccd3c6ef8dddc5816c110a85d538fdacfe04e doc_id: 22560 cord_uid: 89dmmbxh OBJECTIVES: Defined as the energy applied to the respiratory system by ventilator, mechanical power (MP) of ventilation reflects the risk of ventilation-induced lung injury. This study aims to explore the relationship between dynamic changes in MP and prognosis in critically ill patients. METHODS: This was a single-centre retrospective cohort study. Patients receiving mechanical ventilation with acute respiratory failure (ARF) and MP > 10 J/min on admission in the ICU were included. MP (J/min) was calculated as 0.098 × minute ventilation (L/min) × [(peak inspiratory pressure + positive end-expiratory pressure)/2] and the MP variation rate (%) as ([baseline MP − 24-h MP]/baseline MP) × 100. Patients were divided into two groups according to whether MP decreased 24 h after admission (MP-improved group defined as 24-h MP variation rate > 0% vs. MP-worsened group defined as 24-h MP variation rate ≤ 0%). RESULTS: In total, 14,463 patients were screened between January 2015 and June 2020, and finally, a study cohort of 602 patients was obtained. The MP-improved group had a lower ICU mortality rate than the MP-worsened group (24% vs. 36%; p = 0.005). The 24-h MP variation rate was associated with ICU mortality after adjusting for confounders (odds ratio, 0.906 [95% CI 0.833–0.985]; p = 0.021), while baseline MP (p = 0.909) and 24-h MP (p = 0.059) were not. All MP components improved in the MP-improved group, while minute ventilation and positive end-expiratory pressure contributed to the increase in MP in the MP-worsened group. CONCLUSIONS: The 24-h MP variation rate was an independent risk factor for ICU mortality among ARF patients with elevated MP. Early decreases in MP may provide prognostic benefits in this population. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12890-021-01691-4. Critically ill patients with acute respiratory failure (ARF) are usually exposed to high-intensity mechanical ventilation, making them prone to ventilator-induced lung injury (VILI) [1] . Ventilation parameters, including tidal volume [2] , driving pressure [3] , and mean airway pressure [4] , have been shown to correlate with patient outcomes in the intensive care unit (ICU). Among them, the mechanical power (MP) of ventilation has been proposed as a comprehensive index that combines volume, respiratory rate and airway pressure to reflect the intensity of ventilation [5] . MP is the total energy needed to overcome the resistance of a patient's respiratory system over a period, usually expressed as joules per minute (J/ min). Several retrospective studies have indicated that MP is an independent risk factor for predicting short-or long-term outcomes among critically ill patients [6] [7] [8] [9] . To our knowledge, however, studies have usually focused only on the association between baseline MP and prognosis. Very limited evidence exists regarding the dynamic change in MP and patient outcomes in the ICU. As both injurious MP and exposure time are considered essential components of VILI development [10, 11] , a quick reduction in injurious power over time should provide beneficial effects in terms of patient outcomes. The aim of our study was to explore the correlation between the 24-h change in MP and the outcomes of ARF patients with elevated MP on ICU admission. We also intend to investigate the relevant factors behind MP changes, namely, the components of MP, including minute ventilation, positive end-expiratory pressure (PEEP) and respiratory compliance, to find possible effective targets for reducing MP. This is a single-centre retrospective cohort study performed in the Department of Critical Care Medicine of Peking Union Medical College Hospital, a tertiary hospital with 2000 beds receiving more than 110,000 inpatients per year. Approximately 2500 patients, both medical and surgical, are admitted to the ICU each year. Patients with ARF, defined as the ratio of partial pressure of oxygen (PaO 2 ) to fraction of inspired oxygen (FiO 2 ) less than 300 mmHg on admission, who received invasive mechanical ventilation for more than 48 h between 1 January 2015 and 30 June 2020 were eligible for study inclusion. We excluded patients who (1) received treatment with extracorporeal life support; (2) were aged less than 18 years; or (3) had MP ≤ 10 J/min on admission (with a possible lower risk of lung injury [12] ). This study was approved by the Institutional Research and Ethics Committee of Peking Union Medical College Hospital. Lung protective strategies were adopted for all patients admitted to the ICU according to the up-to-date guidelines [13] [14] [15] . Further, quality control targets were set to guide ventilator settings [16] . Specifically, the initial tidal volume was set at 6-8 ml/kg predicted body weight (PBW) using volume-or pressure-controlled mode. Tidal volume and respiratory rate were adjusted according to arterial blood gas with PaCO 2 no less than 40 mmHg to avoid unnecessary ventilation. Appropriate sedation and analgesia were applied to achieve this target. If vigorous spontaneous effort was detected despite adequate sedation and analgesia, neuromuscular blocking agents (NMBA) would be prescribed by the responsible attending intensivist. Initial PEEP and FiO 2 were set based on the lower PEEP-FiO 2 table [2] . After the patient became relatively stable in hemodynamics, subsequent PEEP was titrated through decremental PEEP trial (started from 15 to 20 cmH 2 O, with 3 cmH 2 O as a step, 3-5 min for each step). The optimal PEEP was set by the maximal static respiratory compliance (tidal volume divided by driving pressure) in some patients and by bedside ultrasound (reaeration score to assess lung recruitment) [17] or electrical impedance tomography (the combination of lowest overdistension and collapse) in others [18] . SpO 2 was not allowed to reach 100% unless at room air. The ventilator was switched to pressure support mode considering the following criteria: hemodynamic stability, PaO 2 /FiO 2 ≥ 200 mmHg, PEEP no more than 5 cmH 2 O and some improvement in the underlying condition that caused the respiratory failure [19] . We calculated the dynamic driving pressure as the peak inspiratory pressure minus the PEEP because the plateau pressure was not regularly recorded in our database. Then, MP was calculated as 0.098 × respiratory rate × tidal volume × (peak inspiratory pressure -(0.5 × dynamic driving pressure)), which was equal to 0.098 × minute ventilation (L/min) × [(peak inspiratory pressure + positive end-expiratory pressure)/2] [12] . The 24-h MP variation rate (%) was defined as ([baseline MP − 24-h MP]/baseline MP) × 100. The dynamic compliance of the respiratory system (mL/cmH 2 O) was equal to the tidal volume/dynamic driving pressure. All the clinical data were extracted from the Critical Care Monitor System in Peking Union Medical College Hospital, which recorded real-time clinical data hourly with bedside equipment. To minimize errors, baseline respiratory mechanics and hemodynamic data used in the statistical analyses were an average of the values collected during the first 12 h after ICU admission, and the 24-h corresponding values were an average of the 24 to 36-h values. The primary clinical outcome of this study was ICU mortality. The number of ventilator-free days (defined as the number of days from successful weaning to day 28, with patients who died before weaning being deemed to have no ventilator-free days), length of ICU stay and length of hospital stay were also measured as secondary outcomes. We evaluated the predictive values of baseline MP, 24-h MP and the MP variation rate for ICU mortality rates. Descriptive data are expressed as numbers and percentages for categorical variables and means (SDs) or medians (IQRs) for continuous variables. Categorical variables were compared using the Pearson chi-square test, whereas continuous variables distributed nonparametrically between groups were compared using the Mann-Whitney U test. Baseline and 24-h values of the same parameter were compared using the Wilcoxon signed-rank test. A competing risk model was used to evaluate the effect of the MP decrease on the probability of successful discontinuation of mechanical ventilation, with death as a time-dependent competing event. Comparisons were performed using the Gray test. Multivariate logistic regression model was established to determine the effects of baseline MP, 24-h MP and the MP variation rate for ICU mortality by forward stepwise selection procedure; the model was adjusted for age, sex, Acute Physiology and Chronic Health Evaluation II score, admission type, PaO 2 /FiO 2 ratio and ventilatory ratio on admission [20] , prone positioning and neuromuscular blocking agent treatments within 24 h. Variables introduced in this model were either statistically different between MPworsened and MP-improved groups or considered clinically associated with ICU mortality. The performance of baseline MP, 24-h MP and the MP variation rate were evaluated using the area under the curve of the receiver operating characteristic (AUC-ROC). The differences in AUCs-ROC were analysed by using DeLong's method. We performed multiple imputation to account for missing data (shown in Additional file 1: eTable 1) by generating five imputed datasets for the study population [21] and then repeated the model analyses using these imputed datasets to examine the robustness of the findings from the complete case analysis. All comparisons were two-tailed, and a p value of less than 0.05 was considered statistically significant. Statistical analyses were performed using SPSS for Windows version 25.0 (SPSS, Chicago, IL). During the study period (January 2015 to June 2020), 14,463 patients were recorded in the database, from which 1,925 patients with ARF received mechanical ventilation for more than 48 h. We excluded 34 patients receiving extracorporeal life support during the first day on admission in the ICU, 25 patients with age less than 18 years, 91 patients without complete data for the calculation of MP and another 15 with implausible ventilation data. At the last step, 1,158 patients with MP no more than 10 J/min were excluded, resulting in a cohort of 602 patients (Fig. 1) . The patients had a median age of 61 years (IQR 50-70), and 155 (26%) of them were women. Overall, 436 patients survived, and 166 patients expired, yielding an ICU mortality rate of 28%. These patients were divided into the MP-worsened group (24-h MP variation rate ≤ 0%) and the MP-improved group (24-h MP variation rate > 0%). The clinical characteristics of the study population are shown in Table 1 . Overall, more prone positioning and NMBAs were used in the MP-worsened group. Baseline MP levels between the MP-worsened group and MP-improved group were similar ( Figure 2 shows the result of the competing risk analysis for the time to discontinuation from mechanical ventilation, with death as the competing event. The MP-improved group was associated with a reduced proportion of patients requiring invasive mechanical ventilation at day 28 (29% vs. 42%; Gray test p = 0.0026). 14 (Tables 2 and 3 ). The AUC-ROC of baseline MP tended to decrease in patients with higher baseline MP, while the AUC-ROC values of 24-h MP and the MP variation rate tended to increase. For 107 patients with baseline MP > 15 J/min, the AUC-ROC of the 24-h MP variation rate was higher than that of baseline MP (p = 0.046 by DeLong's test), and the 24-h MP variation rate remained a risk factor in the multivariate logistic regression model (odds ratio per 10% increase, 0.722 [95% CI 0.584-0.892]; p = 0.003). As shown in Table 4 , the baseline tidal volume was lower in the MP-worsened group (6.7 mL/kg [IQR 5.9-7.4 mL/kg] vs. 7.1 mL/kg [IQR 6.4-7.9 mL/kg]; p < 0.001); however, the 24-h minute ventilation was found to be higher in this group (9.0 L/min [IQR 8.1-10.2 L/min] vs 7.5 L/min [IQR 6.5-8.5 L/min]; p < 0.001). PEEP and dynamic compliance of the respiratory system did not differ between groups at baseline (p = 0.353; p = 0.63). They both improved in the MPimproved group, while PEEP was slightly elevated in the MP-worsened group. In both groups, FiO 2 was downregulated, and PaO 2 improved. PaCO 2 was decreased in the MP-wors- Our results showed that the 24-h MP variation rate, adjusted for confounders, was an independent risk factor for ICU mortality among ARF patients with elevated baseline MP. In addition, the main reason for a worsened MP value 24 h after admission was the increase in minute ventilation and PEEP. Several clinical studies have shown that high MP was related to poor outcomes among ICU patients [6] [7] [8] [9] . We consider the dynamic change of MP to be more informative than the MP at a certain time point because the former reflects a patient's response to respiratory treatments, while the latter reflects only the static status of a patient. Response of MP to treatments could be more indicative of disease severity. This may explain why the 24-h MP variation rate remained an independent risk factor after adjusting for confounders, while the baseline MP and 24-h MP were not included in the present study (Table 2) . Recently, Urner et al. [12] reported that cumulative exposure to higher intensities of mechanical ventilation was related to poor outcome, which was in line with our study. Decrease in MP within the first 24 h might be beneficial for patients with elevated MP on admission. To further investigate the impact of lung conditions on our results, we used baseline MP as a stratification factor. Being the total energy load on lungs, the baseline MP, instead of APACHE II score or PaO 2 /FiO 2 ratio, may better reflect the severity of lung injury on admission. Higher baseline MP was in accordance with higher APACHE II score and the ICU mortality (Table 3) . We noticed that the prognostic values for baseline MP, 24-h MP and the MP variation rate were different among several subgroups of our database with various lung conditions on admission. The highest AUC-ROC for baseline MP appeared in unselected ICU patients, which may be due to a majority of patients with low baseline MP and low mortality, then it decreased with the increase in respiratory severity. The tendency of AUC-ROC for 24-h MP and the MP variation rate were the opposite: they tended to have a better performance in more severe cases (Table 3) . It was not surprising that the poor prognostic value of the MP variation rate was seen among MP-unselected ARF patients. For those who did not suffer an injurious power at the start of ventilation, MP fluctuation within a relatively 'safe' range would contribute little to VILI, while for those who were exposed to higher MP on Table 4 Baseline and 24-h respiratory parameters IQR, interquartile range; PBW, predicted body weight; PEEP, positive end-expiratory pressure; Cdyn, dynamic compliance of respiratory system; PaO 2 , partial pressure of arterial oxygen; FiO 2 , fraction of inspired oxygen * p < 0.05 comparing same parameters at baseline and 24-h by Wilcoxon signed-rank test MP variation rate ≤ 0% (MP-worsened, n = 173) p Baseline tidal volume, mL/kg PBW 6.7 (5.9, 7.4) 7.1 (6.4, 7.9) < 0.001 24-h tidal volume, mL/kg PBW 6.9 (6.2, 7.9)* 6.9 (5.9, 7.8)* 0.208 Baseline minute ventilation, L/min 8.4 (7.6, 9.4) 8.6 (7.7, 9.9) 0.115 24-h minute ventilation, L/min 9.0 (8. admission, a quick move to reduce MP would benefit the prognosis. The dynamic changes in MP components among groups were simultaneously investigated. In the MPimproved group, minute ventilation was reduced, accompanied by a median PaCO 2 increase above 40 mmHg (our quality control target). Both PEEP and FiO 2 were downregulated, accompanied by improvements in respiratory compliance and oxygenation. In the MP-worsened group, the effort to reduce minute ventilation seemed to fail despite the use of more NMBAs. Since the 24-h PaCO 2 was similar among groups, a higher minute ventilation could indicate a higher proportion of dead space estimated by the ventilatory ratio [20] and indicate a higher disease severity [22] . Notably, while the oxygenation was improved and FiO 2 was downregulated on the first day, PEEP was somehow increased in the MP-worsened group, contributing to the rise of MP. This may raise an interesting question that whether patients in this group could benefit from lower PEEP and thus lower MP. The answer needs elaborate prospective study design. A relatively low specificity and positive predictive value are explicable. Certain patients with ARF or acute respiratory distress syndrome (ARDS) experience deterioration of lung conditions in the first few days until the primary causes are controlled, during which if not exposed to hazardous MP long enough, they can still recover from acute lung injuries. Therefore, the positive predictive value could be improved in a population with severely high MP. Additionally, a cut-off value of approximately 20% for the MP variation rate would allow a fairly high negative predictive value of 80%, meaning that a quick action to reduce MP would indicate a higher probability of short-term survival. For example, this objective can be achieved by reducing minute ventilation from 10 to 8 L/ min as long as the value of PaCO 2 is within an acceptable range [23] . The control of tidal volume will create a more beneficial effect on MP since the airway pressure will decrease simultaneously, resulting in a larger drop in MP. This again emphasizes the importance of low tidal volumes, as has been strongly recommended in guidelines [14, 15] , while the compliance rate should be enhanced [24] . We also noticed a difference in hemodynamic parameters: the MP-improved group had a lower central venous pressure ( Although there was only a weak correlation between fluid balance and changes in respiratory compliance (Additional file 2: eFigure 1), we reasoned that the removal of extra fluid could contribute to the improvement of oxygenation and respiratory compliance. Evidence from a randomized controlled trial has shown that a conservative strategy of fluid management resulted in improved lung function and a shorter duration of mechanical ventilation in patients with acute lung injury [25] . Our study has certain limitations. First, this study was limited by its post hoc nature inherent to the retrospective analysis. The improvement in MP may reflect a positive response to treatment, yet it does not exclude a prompt correction of incorrect ventilator settings, although we tried to minimize the second possibility by collecting 12-h average value of ventilator parameters. Second, the nature of single-centre study restricted the generalization of our findings to other institutions and patient populations, although the inclusion of consecutive patients reduced the inclusion bias and reflected our practical settings. Third, the baseline MP in our cohort was lower compared with a previous retrospective study showing a possible cut-off MP value at 17 J/min [6] . But the dynamic MP in this study would underestimate the true MP value by replacing plateau pressure with peak inspiratory pressure, creating a bias of minute ventilation × resistive pressure/20 [26] . Fourth, concern may exist regarding whether the simplified formula for MP calculation is suitable for patients under pressure-controlled mode [27] . Pressure-controlled mode only accounted for a small part in this study (around 10%). We also considered the bias between the dynamic MP and the true MP to be minimal according to their geometrical relationship shown in Additional file 2: eFigure 2. Meanwhile, the MP variation rate is less affected by the bias of absolute MP values. Last but not least, the ROC analysis shows that MP variation has a poor predictive value, which may reflect that VILI accounts for only a small part of cause of death in our cohort. The 24-h MP variation rate was an independent risk factor for ICU mortality among patients with ARF and elevated MP. Early decreases in MP may provide prognostic benefits in this population. Tidal volume and minute ventilation seem to be the first and foremost targets in reducing MP. Ventilator-induced lung injury Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome Driving pressure and survival in the acute respiratory distress syndrome Elevated mean airway pressure and central venous pressure in the first day of mechanical ventilation indicated poor outcome Ventilator-related causes of lung injury: the mechanical power Mechanical power of ventilation is associated with mortality in critically ill patients: an analysis of patients in two observational cohorts Epidemiology, mechanical power, and 3-year outcomes in acute respiratory distress syndrome patients using standardized screening. An observational cohort study Mechanical power normalized to predicted body weight as a predictor of mortality in patients with acute respiratory distress syndrome Effect of driving pressure on mortality in ARDS patients during lung protective mechanical ventilation in two randomized controlled trials Determinants and prevention of ventilator-induced lung injury Static and dynamic contributors to ventilator-induced lung injury in clinical practice. Pressure, energy, and power Timevarying intensity of mechanical ventilation and mortality in patients with acute respiratory failure: a registry-based, prospective cohort study BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults An Official American Thoracic Society/European Society of Intensive Care Medicine/Society of Critical Care Medicine Clinical Practice Guideline: mechanical ventilation in adult patients with acute respiratory distress syndrome Guidelines on the management of acute respiratory distress syndrome Effects of quality control targets (SpO 2 ≠ 100%, PaCO 2 /< 40 mmHg, Pmean/> 10 cmH 2 O) on outcomes in patients in the ICU Bedside ultrasound assessment of positive end-expiratory pressure-induced lung recruitment Positive end-expiratory pressure titration after alveolar recruitment directed by electrical impedance tomography Weaning patients from the ventilator Physiologic analysis and clinical performance of the ventilatory ratio in acute respiratory distress syndrome Cost-effectiveness in clinical trials: using multiple imputation to deal with incomplete cost data Higher dead space is associated with increased mortality in critically ill children Experts' opinion on management of hemodynamics in ARDS • fast, convenient online submission • thorough peer review by experienced researchers in your field • rapid publication on acceptance • support for research data, including large and complex data types • gold Open Access which fosters wider collaboration and increased citations maximum visibility for your research: over 100M website views per year • At BMC, research is always in progress. Learn more biomedcentral.com/submissions Ready to submit your research Ready to submit your research ? Epidemiology, patterns of care, and mortality for patients with acute respiratory distress syndrome in intensive care units in 50 countries Comparison of two fluid-management strategies in acute lung injury Mechanical power at a glance: a simple surrogate for volume-controlled ventilation The calculation of mechanical power is not suitable for intra-patient monitoring under pressure-controlled ventilation The authors thank all the subjects for their participation in this study Authors' contributions YC, HH and YL designed and planned the study. YC and QZ extracted the data. YC and HH did the analysis, and QZ, SY, ZZ and YL supervised the analysis. YC The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s12890-021-01691-4. Additional file 2: eFigures. Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.