key: cord-0022331-19h3otmm authors: Brunetti, Giuseppe; Conteduca, Donato; Armenise, Mario Nicola; Ciminelli, Caterina title: Novel Micro-Nano Optoelectronic Biosensor for Label-Free Real-Time Biofilm Monitoring date: 2021-09-29 journal: Biosensors (Basel) DOI: 10.3390/bios11100361 sha: 67badb8e53906bb41a4699f211a3d05a41db2731 doc_id: 22331 cord_uid: 19h3otmm According to the World Health Organization forecasts, AntiMicrobial Resistance (AMR) is expected to become one of the leading causes of death worldwide in the following decades. The rising danger of AMR is caused by the overuse of antibiotics, which are becoming ineffective against many pathogens, particularly in the presence of bacterial biofilms. In this context, non-destructive label-free techniques for the real-time study of the biofilm generation and maturation, together with the analysis of the efficiency of antibiotics, are in high demand. Here, we propose the design of a novel optoelectronic device based on a dual array of interdigitated micro- and nanoelectrodes in parallel, aiming at monitoring the bacterial biofilm evolution by using optical and electrical measurements. The optical response given by the nanostructure, based on the Guided Mode Resonance effect with a Q-factor of about 400 and normalized resonance amplitude of about 0.8, allows high spatial resolution for the analysis of the interaction between planktonic bacteria distributed in small colonies and their role in the biofilm generation, calculating a resonance wavelength shift variation of 0.9 nm in the presence of bacteria on the surface, while the electrical response with both micro- and nanoelectrodes is necessary for the study of the metabolic state of the bacteria to reveal the efficacy of antibiotics for the destruction of the biofilm, measuring a current change of 330 nA when a 15 µm thick biofilm is destroyed with respect to the absence of biofilm. Bacterial infections represent one of the leading causes of death in developing nations [1] . The infections are caused by food poisoning, which is often related to water contamination or improper food preparation [2] . Furthermore, the large overuse and/or misuse of antibiotics is causing a rapid growth in AntiMicrobial Resistance (AMR) worldwide [3] . AMR is developed when the bacteria adapt to and resist antibiotics treatments, which become ineffective to counteract a bacterial infection that can grow and spread in a large community through direct contact, food, or the environment [4, 5] . As a result of the lack of powerful antibiotics, many bacterial infections, such as pneumonia, tuberculosis, and gonorrhoea, are becoming more difficult to eradicate with a consequent higher mortality rate [6] . According to [7] , the cost of AMR on public health is up to 100 trillion USD, and AMR is expected to become the leading cause of death worldwide, with over 10 million annually predicted by 2050. These consequences highlight that AMR is a widespread social problem that cannot be underestimated or neglected anymore due to the large and rising number of people potentially affected. Many bacterial infections are caused by the non-eradication of bacterial biofilm, which can be several times more resistant to antibiotics compared to planktonic bacteria [8, 9] . This behavior is strictly correlated to the intrinsic nature of the biofilm, which consists of densely packed microbial cells that can grow and surround themselves with a selfproduced Extracellular Matrix (ECM). The ECM is composed of proteins, polysaccharides, and nucleic acids that protect the bacterial biofilm from the environment, so making it very resistant to external agents, such as antibiotics [10] . Moreover, a biofilm may include different bacteria, and this makes the dissolution of biofilms more challenging [11] . In fact, it has been demonstrated that even if a biofilm is treated by an antibiotic that is efficient for a specific planktonic bacterium or small communities of bacteria with a concentration much higher than Minimum Biofilm Inhibitory Concentration (MIC), which represents the lowest concentration of drug to prevent the bacteria growth, the biofilm structure can be completely unaltered, showing a continuous growth process also after the treatment [12] . To date, the most widely used diagnostics to detect the presence of bacteria and analyze their evolution under several antibiotics' treatment is the plate-count method, which is based on the growth of bacteria on an agar plate [13, 14] . However, this technique is time consuming (24-72 h) , because it requires many cell-division cycles as well as expert users for the sample preparation and final analysis. The large time delay is the most significant bottleneck of such a technique because several infections, such as sepsis, require an immediate measure, also to avoid the formation of a biofilm [15] . The antibiotics are commonly administered in the clinicians' experience with a not-negligible failure rate, so possibly leading to an outbreak of the resistance rather than by carrying out an accurate diagnosis. Thus, novel diagnostic techniques that can rapidly detect and identify bacteria and confirm the presence of a biofilm, ideally within 30 min, are needed. Furthermore, these techniques should also enable study of the efficiency of antibiotics with a real-time analysis during the treatment in order to define the most powerful antibiotic, the best concentration, and the administration time for each infection [16] . During the last few years, several approaches have been investigated, mainly with the use of optical techniques, such as Raman Spectroscopy or fluorescence, due to their high resolution and real-time detection of individual bacteria [17] [18] [19] . However, these methods are not label-free, becoming inefficient in the presence of bacteria mutations, and allow investigating only a small area. Integrated optical devices have also been used for single bacteria analysis with label-free techniques [20] . In particular, resonant cavities are able to trap and identify single bacteria through the changes of the resonance response [21, 22] . Emerging studies with a label-free optical-based approach have demonstrated real-time monitoring of cell attachment and the development of bacteria on the sensor surface [23] . Optical devices have been used to investigate the antimicrobial susceptibility with in vitro studies by adopting antibiotics with concentrations compliant with standard health protocols [23] . However, the simultaneous detection of several bacteria in the whole biofilm volume is still challenging because of the mismatch between the biofilm thickness and evanescent field penetration depth. In fact, the evanescent field of resonant cavities typically extends for few hundreds of nanometers, thus making impossible the detection of multiple bacteria organized in a three-dimensional configuration as a biofilm that can reach a thickness of several microns in the presence of macro-colonies in the maturation phase. The mechanical trapping of bacteria has also been obtained by using microfluidic devices [24, 25] , allowing the bacteria localization in specific areas to accurately detect and analyze them with an atomic force microscope (AFM) [26] . The AFM technique guarantees a very high resolution, also providing relevant information about the metabolic state of bacteria and if they are live/dead, for example by observing a different motility with a change of amplitude and noise in the electrical signal [26] . However, the mechanical trapping has a trapping time not long enough to investigate the metabolic activity of bacteria and their interactions in large communities, so making also difficult their differentiation in the biofilm. The aforementioned critical issues have been partly mitigated by Electrochemical Impedance Spectroscopy (EIS) [27] [28] [29] [30] [31] . In particular, device configurations based on inter-digitated microelectrodes have been exploited for the analysis of the metabolic activity of bacteria and their differentiation [27] . This approach is characterized by a great penetration of the electric field in the biofilm, in contrast to the integrated optical devices where the distribution of the evanescent field of the optical resonant mode within the biofilm is limited [32] , as demonstrated in the next sections. Therefore, the electrical behavior guarantees the capability of studying the biofilm evolution and the action of the antibiotics. However, the lowest detection limit of EIS is around 10 CFU/mL [31] , which means no high resolution down to single cells. Moreover, the detection time is longer compared to other trapping approaches, such as optical and mechanical ones, because, in case of low initial concentration, the growth of the cells is required before achieving a detectable change of impedance, which usually takes a few hours [33] . The resolution can be improved by different configurations of electrochemical biosensors, such as interdigitated nanoelectrodes, which compared to the bulk configuration of single electrodes allow the enhancement of the electric field in the device and then, a stronger interaction between the field and the bacteria [34] . However, if the resolution improvement is achieved at the expense of a shorter penetration length of the electric field, the analysis of the bacteria metabolism in a biofilm would be impossible. From this brief overview on the techniques for the detection and analysis of bacteria, it is clear that a single interrogation technique is not sufficient for a full assessment of the antibiotic susceptibility on planktonic bacteria and, in particular, on bacterial biofilms. Multiple approaches should be used in parallel, leading to a multiparameter approach [35, 36] . Here, we propose the design of a novel optoelectronic device based on an on-chip dual array of interdigitated micro-and nanoelectrodes that combines together optical and electrical techniques to monitor the growth of a biofilm and to analyze the effect of antibiotics on the bacteria. The optical approach allows the detection of few bacteria with a high spatial resolution to understand their interaction and which biological events are involved during the initial phase of the biofilm formation. The electrical approach allows the simultaneous study of the evolutionary phases of the bacterial biofilm and, by analyzing the impedance changes, the evaluation of the biofilm growth and maturation, and the efficacy of antibiotics for the disruption of the biofilm, which are useful in AMR studies. The dual array is formed by an Interdigitated Micro Electrodes (IMEs) section and an Interdigitated Nano Electrodes (INEs) section, which are both realized in Silicon-On-Sapphire (SOS) technology and fed by an AC voltage (see Figure 1a ). In order to perform both optical and electrical measurements to study the properties of planktonic bacteria or a bacterial biofilm in the whole sensor area, the two sections are arranged adjacent, spaced from each other only by a few microns. P-doping has been assumed for silicon, with an exponential decay of the electrical conductivity from the surface in depth with a drop more than three orders of magnitude in few tens of nanometers, as described in Section 4.1, reaching very low values of resistivity at the surface, and also strongly reducing the optical losses correlated to the dopant concentration [37] . The INEs section can be assumed as a top-illuminated subwavelength grating, whose cross-section is sketched in Figure 1 , that supports the Guided Mode Resonance (GMR) effect [38] . It is correlated to the quasi-guided modes or leaky modes of the structure, as shown by the grating in Figure 1a . The grating acts as a waveguiding layer in the x-y plane, where the input light excites quasi-guided or leaky modes that coherently scatter at each interface of the grating. Furthermore, leaky modes scatter power downwards, along the vertical direction perpendicular to the grating (z-axis). By properly engineering the grating features, such as the period, the refractive indices, and the angle of incidence, the interference between the transmitted light and the downward wave scattered by the leaky mode could generate reflected light along the negative direction of the z-axis with maximum amplitude at resonance [39, 40] . By properly engineering the grating features, such as the period, the refractive indices, and the angle of incidence, the interference between the transmitted light and the downward wave scattered by the leaky mode could generate reflected light along the negative direction of the z-axis with maximum amplitude at resonance [39, 40] . The structure exploiting the GMR effect has been designed to obtain a resonance condition for λ > 800 nm, where the absorption losses of silicon decrease [41] , with the aim of achieving a higher extinction ratio and higher Q-factor, together with a strong energy confinement close to the surface to enhance the light interaction with the bacteria. The strong refractive index contrast between silicon and the surrounding medium allows a high confinement of the electromagnetic field at the sensor surface, enabling the use of the INEs section for hyperspectral imaging technique, as described in detail in [42] , which allows the refractive index imaging, thus localizing objects on the grating by detecting the spatial resonance distribution. An inverted microscope configuration can be used to characterize the sensor, with the light source illuminating from the top and the reflected signal collected from the same side of the setup by a conventional CMOS camera. In order to work at the bacteria scale, we assume as a best compromise in terms of resolution and the large field of view an optical setup with an area of 1 mm 2 and a spatial resolution down to few microns. This allows having a large area but still exploiting the advantages of near-field optics, in particular in terms of strong resolution. This approach has been experimentally validated in the literature with simple and feasible systems [42] . This behavior is also useful to obtain additional information about the first stage of the bacteria infection, when the bacteria cells enrich before they start to interact with each other to form the biofilm. During the biofilm formation, the cells produce extracellular polymeric substances (EPS), creating the surrounding matrix to protect the bacteria. The main EPS components are polysaccharides, proteins, lipids, and DNA with dimensions much smaller than the bacterial cells [43] . The real-time detection of the biofilm formation with label-free techniques is very challenging, mainly because the matrix generation begins when the first layers of bacteria close to the sensor surface are packed and arranged in large communities. Under this condition, the monitoring of the chemical and biological The structure exploiting the GMR effect has been designed to obtain a resonance condition for λ > 800 nm, where the absorption losses of silicon decrease [41] , with the aim of achieving a higher extinction ratio and higher Q-factor, together with a strong energy confinement close to the surface to enhance the light interaction with the bacteria. The strong refractive index contrast between silicon and the surrounding medium allows a high confinement of the electromagnetic field at the sensor surface, enabling the use of the INEs section for hyperspectral imaging technique, as described in detail in [42] , which allows the refractive index imaging, thus localizing objects on the grating by detecting the spatial resonance distribution. An inverted microscope configuration can be used to characterize the sensor, with the light source illuminating from the top and the reflected signal collected from the same side of the setup by a conventional CMOS camera. In order to work at the bacteria scale, we assume as a best compromise in terms of resolution and the large field of view an optical setup with an area of 1 mm 2 and a spatial resolution down to few microns. This allows having a large area but still exploiting the advantages of near-field optics, in particular in terms of strong resolution. This approach has been experimentally validated in the literature with simple and feasible systems [42] . This behavior is also useful to obtain additional information about the first stage of the bacteria infection, when the bacteria cells enrich before they start to interact with each other to form the biofilm. During the biofilm formation, the cells produce extracellular polymeric substances (EPS), creating the surrounding matrix to protect the bacteria. The main EPS components are polysaccharides, proteins, lipids, and DNA with dimensions much smaller than the bacterial cells [43] . The real-time detection of the biofilm formation with label-free techniques is very challenging, mainly because the matrix generation begins when the first layers of bacteria close to the sensor surface are packed and arranged in large communities. Under this condition, the monitoring of the chemical and biological processes in these communities is difficult because the propagation length of the evanescent field, of the order of few hundreds of nanometers, corresponds only to the first layer of bacteria. Therefore, the optical approach is efficient for analyzing the first stages of the biofilm formation when bacteria begin to form colonies, while a different approach should be investigated to clearly define the presence of a biofilm with its extracellular matrix. To meet this latter requirement, the INEs section has been designed to allow simultaneous optical and electrical measurements. In fact, several pairs of nanoelectrodes can be realized in an interdigitated configuration, by connecting in turn the doped silicon structures to two different metal electrodes, as shown in Figure 1c , so forming several capacitors at the nanoscale. This system of interdigitated electrodes can allow easy monitoring of the large change of the PH and the electrical properties of the solution induced by the secretion of proteins, DNA, and other EPS components when the bacteria colonies start to create the extracellular matrix [44] . In particular, the capacitance of the system changes when the bacteria start to grow because of the strong interaction between the electric field and the bacteria. Low-frequency values are usually used to detect changes of the system capacitance, because under this condition, the bacterial membrane behaves as a barrier to prevent the penetration of the electric field into the cytoplasm of the bacteria, which usually has a much higher conductivity, in order to make more evident any change of the impedance in proximity of the electrodes. The INE section supporting the GMR effect guarantees the confinement of the electric field close to its top surface [34] , where the bacteria grow and the chemical processes happen, with an improved sensitivity compared to other electrical approaches with different systems and configurations. Therefore, the INEs provide high spatial resolution for imaging few bacteria through an optical approach, to investigate the bacteria interaction to form colonies, and an electrical approach to analyze the biofilm evolution, due to the presence of EPS components that change the electrical properties of the solution, and, therefore, interfere with the electric field distribution. This interaction induces a change of the capacitance C i of the nanocapacitor formed by each pair of nanoelectrodes, which depends on the electrical properties of the surrounding medium and the electrode geometry [44] . The net capacitance of the system, C tot , is given by the sum of the single capacitances C i in parallel combination. A voltage of few millivolts and low frequency have been assumed, to have a low power interacting with bacteria with consequent strongly reduced risks, such as bacteria membrane collapses or changes of their metabolic state. An AC signal at low frequency, i.e., f 1 ≈100 Hz, is necessary to detect any change of the system capacitance [45] . The net impedance of the system is given by Z = 1/jωC tot = 1/jωNC i , where N is the number of nanocapacitors in the interdigitated configuration. This corresponds to a maximum value of current i max = V 0 /|Z| = ωV 0 NC i , which can be increased with the number of pairs of electrodes, leading to the increase in the Signal-to-Noise Ratio (SNR) and the sensitivity. Since a higher sensitivity also corresponds to a faster saturation of the impedance change, due to the strong confinement of the electric field, which is not affected by the impedance changes in the upper layers of the biofilm, the main limitation of the INEs is given by the narrow dynamic range [46] . To monitor the biofilm upper layers, a great penetration depth of the electric field is needed, with a resulting large dynamic range and a lower sensitivity. For this reason, the sensor also includes an IMEs section placed next to the INEs structure (see Figure 1a ). Since the penetration depth L of the electric field is proportional to the gap G and to the width W of the electrodes (L-W), features at the microscale lead to a large penetration depth and dynamic range [47] . In particular, by assuming W > 10 µm, any change of the metabolic state of the biofilm can be monitored as an impedance change. To improve the SNR, an IMEs driving voltage frequency f 2 larger than 1 kHz can be used, where the biofilm shows resistive behavior. According to the above-mentioned net impedance equation, an increase in the electrodes' driving voltage leads to a decrease in the impedance Z, allowing improvement in the accuracy of the detected changes in the biofilm with respect to the INEs section. Although INEsand IMEs-based biosensors have been already widely investigated, see as examples [48, 49] , we note that the main novelty of the proposed optoelectronic device is the combination of both optical and electrical approaches to perform on the same platform and at the same time the efficient monitoring of the bacteria growth and the analysis of the resulting biofilm under antibiotics treatment. According to the above, it can be said that the high sensitivity is provided by INEs through a strong confinement of the electric field close to the top silicon surface, while the IMEs allow analyzing the growth and the maturation of the biofilm and studying its full or partial disruption induced by the antibiotic treatment for a complete, accurate, and real-time monitoring of the biofilm properties and analysis of AMR to specific antibiotics. The driving voltages V 1 and V 2 for INEs and IMEs, respectively, can be the same to simplify the setup of the system, while an IMEs driving voltage frequency f 2 larger than the INEs one is preferred to improve the SNR. The system configuration could be realized following typical fabrication processes. For example, a lithographic process followed by reactive-ion etching can be used to define both the INEs and IMEs structures, while photolithography followed by metal evaporation and lift-off can be applied for the metal pads ( Figure 1 ). The optical section, as already mentioned, consists of a GMR structure with a subwavelength grating in SOS technology. A doped silicon was assumed for doing electrical measurements, with a dopant concentration N D = 10 21 cm −3 at the surface and an exponential drop-off to N D = 10 18 cm −3 within 20 nm, which can be achieved by thermal diffusion doping [37, 50] . This doping profile allows minimizing the optical losses, without any worsening of electrical performance. The geometrical features of the silicon subwavelength grating have been designed to enhance both electrical and optical performance. A resonance condition around λ = λ res ≈ 850 nm is required to minimize optical losses due to the material absorption typical for silicon at lower wavelengths. To fulfill all the requirements, including fabrication tolerances, we have determined a thickness t = 270 nm, a period Λ n = 440 nm, and a fill factor FF = 0.5, corresponding to w = g = 220 nm (see Figure 2a) . Furthermore, since the grating strength, and then the Q-factor, increases with the number of periods, thousands of periods have been assumed, without affecting the ability to detect the bacteria with a resolution of a few microns. Although INEs-and IMEs-based biosensors have been already widely investigated, see as examples [48, 49] , we note that the main novelty of the proposed optoelectronic device is the combination of both optical and electrical approaches to perform on the same platform and at the same time the efficient monitoring of the bacteria growth and the analysis of the resulting biofilm under antibiotics treatment. According to the above, it can be said that the high sensitivity is provided by INEs through a strong confinement of the electric field close to the top silicon surface, while the IMEs allow analyzing the growth and the maturation of the biofilm and studying its full or partial disruption induced by the antibiotic treatment for a complete, accurate, and real-time monitoring of the biofilm properties and analysis of AMR to specific antibiotics. The driving voltages V1 and V2 for INEs and IMEs, respectively, can be the same to simplify the setup of the system, while an IMEs driving voltage frequency f2 larger than the INEs one is preferred to improve the SNR. The system configuration could be realized following typical fabrication processes. For example, a lithographic process followed by reactive-ion etching can be used to define both the INEs and IMEs structures, while photolithography followed by metal evaporation and lift-off can be applied for the metal pads (Figure 1 ). The optical section, as already mentioned, consists of a GMR structure with a subwavelength grating in SOS technology. A doped silicon was assumed for doing electrical measurements, with a dopant concentration ND = 10 21 cm −3 at the surface and an exponential drop-off to ND = 10 18 cm −3 within 20 nm, which can be achieved by thermal diffusion doping [37, 50] . This doping profile allows minimizing the optical losses, without any worsening of electrical performance. The geometrical features of the silicon subwavelength grating have been designed to enhance both electrical and optical performance. A resonance condition around λ = λres ≈ 850 nm is required to minimize optical losses due to the material absorption typical for silicon at lower wavelengths. To fulfill all the requirements, including fabrication tolerances, we have determined a thickness t = 270 nm, a period Λn = 440 nm, and a fill factor FF = 0.5, corresponding to w = g = 220 nm (see Figure 2a) . Furthermore, since the grating strength, and then the Q-factor, increases with the number of periods, thousands of periods have been assumed, without affecting the ability to detect the bacteria with a resolution of a few microns. The reflection spectrum of the grating has been calculated by the 3D Finite Element Method (FEM), assuming top out-of-plane excitation with TE-polarized and plane-wave collimated light (the electric field is oriented perpendicularly to the grating period direction). Reflection spectrum and mode distribution at the resonance frequency are reported in Figure 2b ,c, respectively. The reflection spectrum of the grating has been calculated by the 3D Finite Element Method (FEM), assuming top out-of-plane excitation with TE-polarized and plane-wave collimated light (the electric field is oriented perpendicularly to the grating period direction). Reflection spectrum and mode distribution at the resonance frequency are reported in Figure 2b ,c, respectively. The Lysogeny Broth (LB) (n LB = 1.333 + 5 × 10 −7 i) has been assumed as the surrounding medium, which is a typical medium for bacteria, and the substrate is sapphire with n sub = 1.732. A resonance condition at λ res ≈ 841.5 nm has been calculated. At λ res, with the aforementioned doping profile, a refractive index of silicon n Si = 2.76 + 0.06 i at the surface results, which increases up to n Si = 3.648 + 4 × 10 −3 i at 20 nm far from the surface. The resonance shows an amplitude higher than 0.8, which is normalized with respect to the input power, and a Full Width at Half Maximum (FWHM) = 2.12 nm, which corresponds to Q ≈ 400. The proposed configuration represents the best compromise to achieve a high Q-factor, large modal confinement, and high resonance amplitude, which is useful for hyperspectral imaging and sensing. The operation of the GMR structure in the presence of bacteria has been simulated by assuming a uniform and homogeneous layer of bacteria with a thickness t layer of the order of hundreds of nm and refractive index n bac . For example, the Escherichia coli bacterium was considered, with a diameter t bac of 500 nm, a length l bac of 2 µm, and a refractive index n bac = 1.388 [51] . Since the length of the bacteria l bac is larger than the gap size g, the penetration of bacteria in the grooves is not allowed. Therefore, the grooves have been assumed to be filled by LB medium. The comparison between the 1D silicon GMR surrounded by LB only and the same structure with the presence of bacteria in solution is shown in Figure 3 . A resonance shift ∆λ res of about 0.9 nm in the case of the bacteria layer on the GMR structure, with a reflection change of about 0.02, was evaluated. This behavior confirms a high resolution in detecting the presence of the bacteria, even when the surface is not fully covered. The Lysogeny Broth (LB) (nLB = 1.333 + 5 × 10 −7 i) has been assumed as the surrounding medium, which is a typical medium for bacteria, and the substrate is sapphire with nsub = 1.732. A resonance condition at λres ≈ 841.5 nm has been calculated. At λres, with the aforementioned doping profile, a refractive index of silicon nSi = 2.76 + 0.06 i at the surface results, which increases up to nSi = 3.648 + 4 × 10 −3 i at 20 nm far from the surface. The resonance shows an amplitude higher than 0.8, which is normalized with respect to the input power, and a Full Width at Half Maximum (FWHM) = 2.12 nm, which corresponds to Q ≈ 400. The proposed configuration represents the best compromise to achieve a high Q-factor, large modal confinement, and high resonance amplitude, which is useful for hyperspectral imaging and sensing. The operation of the GMR structure in the presence of bacteria has been simulated by assuming a uniform and homogeneous layer of bacteria with a thickness tlayer of the order of hundreds of nm and refractive index nbac. For example, the Escherichia coli bacterium was considered, with a diameter tbac of 500 nm, a length lbac of 2 µm, and a refractive index nbac = 1.388 [51] . Since the length of the bacteria lbac is larger than the gap size g, the penetration of bacteria in the grooves is not allowed. Therefore, the grooves have been assumed to be filled by LB medium. The comparison between the 1D silicon GMR surrounded by LB only and the same structure with the presence of bacteria in solution is shown in Figure 3 . A resonance shift Δλres of about 0.9 nm in the case of the bacteria layer on the GMR structure, with a reflection change of about 0.02, was evaluated. This behavior confirms a high resolution in detecting the presence of the bacteria, even when the surface is not fully covered. Since the evanescent field of the optical mode extends and interacts with the biofilm for a few hundred nanometers (< 1 µm, while the optical approach provides the spatial distribution of bacteria along the grating with a much higher resolution, of the order of hundreds of nm, so demonstrating the strong complementarity of the methods. Since the strong electric field confinement of the INE structure causes the saturation of the impedance value, even with a single layer of bacteria in the biofilm, negligible changes of the impedance for a thicker layer of biofilm were confirmed by FEM simulations. This restriction justifies the combination of the INE and IME structures in order to also detect a thicker biofilm for the study of the maturation phase and for the analysis of a possible biofilm disruption by using antibiotics whose results are challenging only with the INE structure. The same thickness and doping distribution of the INEs described in Section 4.1 were assumed for the configuration of the IMEs to realize the proposed array with a single manufacturing process. As above introduced, the IMEs function is providing an accurate analysis of the biofilm maturation and its possible disruption through an interaction of the electric field distribution with the upper layers of the bacterial biofilm. A design different from INEs, in terms of width W, gap G between the electrodes, and period Λ m (see Figure 1c ) is required. The electric field distribution for different values of width W is in Figure 5 , for different values of W (W = 5 µm, 10 µm, and 15 µm with W = G). The numerical results confirm that a larger value of W and G allows confining the electric field farther away from the electrodes, as required for the IME structure, at the expense of a decrease in the current density J 2 [A/m 2 ] due to a worsening of the related capacitance value. The same thickness and doping distribution of the INEs described in Section 4.1 were assumed for the configuration of the IMEs to realize the proposed array with a single manufacturing process. As above introduced, the IMEs function is providing an accurate analysis of the biofilm maturation and its possible disruption through an interaction of the electric field distribution with the upper layers of the bacterial biofilm. A design different from INEs, in terms of width W, gap G between the electrodes, and period Λm (see Figure 1c ) is required. The electric field distribution for different values of width W is in Figure 5 , for different values of W (W = 5 µm, 10 µm, and 15 µm with W = G). The numerical results confirm that a larger value of W and G allows confining the electric field farther away from the electrodes, as required for the IME structure, at the expense of a decrease in the current density J2 [A/m 2 ] due to a worsening of the related capacitance value. The performance of the IME configuration without the bacterial biofilm was defined by FEM simulations for different values of the width, assuming a number of electrodes N = 100, aiming at preserving the device compactness. Figure 6 shows the change of the capacitance for different values of W (assuming G = W) with respect to the capacitance C0 calculated when the IMEs are not covered by the biofilm layer. The same model based on the MMT has been used to define the electrical performance for IMEs, as already proposed for the nanoelectrodes. The presence of multiple layers of bacteria has been considered for the biofilm, with each layer of bacteria assumed with a thickness of 1 µm. As expected, the capacitance changes quickly for small gap values due to the stronger energy confinement, but this also corresponds to a more evident nonlinear behavior for a thickness of the biofilm of few microns (see Figure 6a ), which makes the rigorous analysis of the biofilm behavior challenging, even with several layers of bacteria. The performance of the IME configuration without the bacterial biofilm was defined by FEM simulations for different values of the width, assuming a number of electrodes N = 100, aiming at preserving the device compactness. Figure 6 shows the change of the capacitance for different values of W (assuming G = W) with respect to the capacitance C 0 calculated when the IMEs are not covered by the biofilm layer. The same model based on the MMT has been used to define the electrical performance for IMEs, as already proposed for the nanoelectrodes. The presence of multiple layers of bacteria has been considered for the biofilm, with each layer of bacteria assumed with a thickness of 1 µm. As expected, the capacitance changes quickly for small gap values due to the stronger energy confinement, but this also corresponds to a more evident nonlinear behavior for a thickness of the biofilm of few microns (see Figure 6a) , which makes the rigorous analysis of the biofilm behavior challenging, even with several layers of bacteria. For example, a value of G = W = 5 µm presents a nonlinear behavior up to 5 µm, where the capacitance reaches its saturation value. For a biofilm thickness larger than 5 µm, the changes of impedance are negligible, making impossible the analysis of the upper biofilm layers. On the contrary, a larger value of G provides a more evident linear behavior of the capacitance change with respect to the thickness of the biofilm at the expense of less sensitivity. In fact, for G = W = 100 µm, a linear behavior of the capacitance has been observed for a thickness of the biofilm of at least 15 µm. However, an impedance change of about 10% has been calculated for a thickness of the biofilm of 10 µm, while the impedance variation goes down to 5% with a thickness of 5 µm, which is six times lower than the performance obtained with G = 5 µm for the same biofilm thickness. For example, a value of G = W = 5 µm presents a nonlinear behavior up to 5 µm, where the capacitance reaches its saturation value. For a biofilm thickness larger than 5 µm, the changes of impedance are negligible, making impossible the analysis of the upper biofilm layers. On the contrary, a larger value of G provides a more evident linear behavior of the capacitance change with respect to the thickness of the biofilm at the expense of less sensitivity. In fact, for G = W = 100 µm, a linear behavior of the capacitance has been observed for a thickness of the biofilm of at least 15 µm. However, an impedance change of about 10% has been calculated for a thickness of the biofilm of 10 µm, while the impedance variation goes down to 5% with a thickness of 5 µm, which is six times lower than the performance obtained with G = 5 µm for the same biofilm thickness. Figure 6b confirms the nonlinear trend of the capacitance for smaller values of G, which becomes negligible with a larger W, in addition to a narrower dynamic range of the relative capacitance change ΔC/C0 that also corresponds to a lower sensitivity. The conditions G = W = 50 µm, and then, Λm = 100 µm, have been chosen as the best compromise in terms of linearity and sensitivity, obtaining an impedance change up to 20% with a biofilm thickness of 15 µm. Since the detection of the changes of capacitance at the interface of the electrodes is not necessary, as required instead for the INEs, a frequency f2 of 1 kHz has been assumed for the simulation of the current (i2 in Figure 1a ) changes with different thickness of the biofilm in order to probe electrical changes in the bulk solution [57] . The electrical performance by varying the biofilm thickness is reported in Figure 7 . A change of the current i2 from i2 = 1.76 up to 2.09 µA with a quasi-linear behavior has been calculated, enabling the detection of the current change for each layer of biofilm that confirms the ability to easily detect both the bacterial biofilm growth and maturation, together with its possible disruption caused by the action of the antibiotics. A similar behavior represents a significant improvement for AMR because an efficient, accurate, and real-time analysis of the bacteria interaction and useful information about their life in community and colonies can be achieved. Furthermore, the electrical measurements of the IMEs ensure an accurate analysis of the metabolic state of the biofilm during the whole process from the formation to the maturation and, possibly, the disruption for specific antibiotics. Figure 6b confirms the nonlinear trend of the capacitance for smaller values of G, which becomes negligible with a larger W, in addition to a narrower dynamic range of the relative capacitance change ∆C/C 0 that also corresponds to a lower sensitivity. The conditions G = W = 50 µm, and then, Λ m = 100 µm, have been chosen as the best compromise in terms of linearity and sensitivity, obtaining an impedance change up to 20% with a biofilm thickness of 15 µm. Since the detection of the changes of capacitance at the interface of the electrodes is not necessary, as required instead for the INEs, a frequency f 2 of 1 kHz has been assumed for the simulation of the current (i 2 in Figure 1a ) changes with different thickness of the biofilm in order to probe electrical changes in the bulk solution [57] . The electrical performance by varying the biofilm thickness is reported in Figure 7 . A change of the current i 2 from i 2 = 1.76 up to 2.09 µA with a quasi-linear behavior has been calculated, enabling the detection of the current change for each layer of biofilm that confirms the ability to easily detect both the bacterial biofilm growth and maturation, together with its possible disruption caused by the action of the antibiotics. A similar behavior represents a significant improvement for AMR because an efficient, accurate, and real-time analysis of the bacteria interaction and useful information about their life in community and colonies can be achieved. Furthermore, the electrical measurements of the IMEs ensure an accurate analysis of the metabolic state of the biofilm during the whole process from the formation to the maturation and, possibly, the disruption for specific antibiotics. An innovative label-free biosensing platform based on a dual array of interdigitated electrodes for simultaneous optical and electrical measurements has been proposed for the analysis of bacteria and their interaction. A multiparametric approach for the INEs An innovative label-free biosensing platform based on a dual array of interdigitated electrodes for simultaneous optical and electrical measurements has been proposed for the analysis of bacteria and their interaction. A multiparametric approach for the INEs section offers high sensitivity to detect a very low concentration of planktonic bacteria and possibly down to a single cell, also ensuring the following of the biofilm formation in the initial stage. In addition, the electrical performance of the IMEs enables the monitoring of the growth and the maturation of the biofilm to possibly investigate the efficiency of the antibiotics. The overall performance, related to the merging of the micro and nano scale, outperforms the competitive technologies, whose operation is limited to monitoring a few biofilm formation stages. Therefore, the main advantage of the proposed system is the capability to detect and monitor in real time a biofilm, also analyzing its metabolic state and evolution phase. In its proof-of-concept form, the proposed optoelectronic device has been used for the monitoring of Escherichia coli-based biofilm, but the device could also be investigated to analyze biofilms formed by different strains and species of bacteria. Therefore, the proposed detection method's results are very promising due to high sensitivity, low-cost fabrication, and real-time operation, paving the way to a real-time and cost-effective solution to counteract the AMR phenomenon. World Health Organization. WHO Estimates of the Global Burden of Foodborne Diseases: Foodborne Disease Burden Epidemiology Reference Group Antimicrobial resistance: Implications and costs Antibiotic resistance of bacteria in biofilm Antibiotic resistance and its cost: Is it possible to reverse resistance? Origin and proligeration of multiple-drug resistance in bacterial pathogens Antimicrobial Resistance: Tackling a Crisis for the Health and Wealth of Nations Biofilms: An emergent form of bacterial life Bacterial biofilms: A common cause of persistent infections The biofilm matrix Bacterial biofilm development as a multicellular adaption: Antibiot resistance and new therapeutic strategies Biofilm bacteria: Formation and comparative susceptibility to antibiotics The use of lysozyme modified with fluorescein for the detection of Gram-positive bacteria Baicalin promotes the bacteriostatic activity of lysozyme on S. aureus in mammary glands and neutrophilic granulocytes in mice Enrichment of the lung microbiome with gut bacteria in sepsis and the acute respiratory distress syndrome Antimicrobial resistance in the next 30 years, humankind, bugs and drugs: A visionary approach Design of an optical trapping device based on an ultra-high Q/V resonant structure Ultra-high Q/V hybrid cavity for strong light-matter interaction Detecting Phenotiypically Resistant Mycobacterium tuberculosis using wavelength modulated Raman spectroscopy Nano-optical trapping of rayleigh particles and Escherichia coli bacteria with resonant optical antennas Gram-type differentiation of bacteria with 2D hollow photonic crystal cavities Monitoring of individual bacteria using electro-photonic traps Attachment and antibiotic response of early-stage biofilms studied using resonant hyperspectral imaging Microfluidics for manipulating cells Microfluidic cantilever detects bacteria and measures their susceptibility to antibiotics in small confined volumes Advances in atomic force microscopy for single-cell analysis Rapid bacterial detection with an interdigitated array electrode by electrochemical impedance spectroscopy A review on impedimetric immunosensors for pathogen and biomarker detection Electrochemical biosensors for pathogen detection Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector Detection of viable Salmonella using microelectrode-based capacitance measurement coupled with immunomagnetic separation Outer membrane Permeability and Antibiotic Resistance Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium DNA hybridization detection by electrochemical impedance spectroscopy using interdigitated nanoelectrodes New optoelectronic device for study antimicrobial resistance An integrated electro-optical biosensor system for rapid, low-cost detection of bacteria Electrical conduction and optical properties of doped silicon-on-insulator photonic crystals New principle for optical filters Theory and applications of guided-mode resonance filters Reflection and transmission guided-mode resonance filters Dielectric functions and optical parameters of Si, Ge, GaP, GaAs, GaSb, InP, InAs, and InSb from 1.5 to 6.0 eV Dielectric nanohole array metasurface for high-resolution near-field sensing and imaging Bacterial Biofilms: From the natural environment to infectious diseases Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance An integrated microsystem for real-time detection and threshold-activated treatment of bacterial biofilms Ac electrokinetics: A review of forces in microelectrodes structures Label-free detection of DNA with interdigitated micro-electrodes in a fluidic cell Silicon-on-insulator guided mode resonant grating for evanescent field molecular sensing Electrooptical effects in silicon Real-Time measurement of single bacterium's refractive index using optofluidic immersion refractometry Influence of attached bacteria and biofilm on double-layer capacitance during biofilm monitoring by electrochemical impedance spectroscopy Study of interdigitated electrode arrays using experiments and finite element models for the evaluation of sterilization processes Electromechanics and MEMS Characterization of heterogeneous systems by dielectric spectroscopy Dielectric properties of E.coli cell as simulated by three-shell spheroidal model Interdigitated nanoelectrodes for nanoparticle detection Institutional Review Board Statement: Not applicable. Data Availability Statement: Not applicable. The authors declare no conflict of interest.