key: cord-0022126-dgq8yinm authors: Chu, Jiyon; Shin, Juyoun; Kang, Shinseok; Shin, Sun; Chung, Yeun-Jun title: Rapid and sensitive detection of Salmonella species targeting the hilA gene using a loop-mediated isothermal amplification assay date: 2021-09-30 journal: Genomics Inform DOI: 10.5808/gi.21048 sha: 230440ede8ffb8d2574b9e3452a1834d1b7c5c5d doc_id: 22126 cord_uid: dgq8yinm Salmonella species are among the major pathogens that cause foodborne illness outbreaks. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of Salmonella species. We designed LAMP primers targeting the hilA gene as a universal marker of Salmonella species. A total of seven Salmonella species strains and 11 non-Salmonella pathogen strains from eight different genera were used in this study. All Salmonella strains showed positive amplification signals with the Salmonella LAMP assay; however, there was no non-specific amplification signal for the non-Salmonella strains. The detection limit was 100 femtograms (20 copies per reaction), which was ~1,000 times more sensitive than the detection limits of the conventional polymerase chain reaction (PCR) assay (100 pg). The reaction time for a positive amplification signal was less than 20 minutes, which was less than one-third the time taken while using conventional PCR. In conclusion, our Salmonella LAMP assay accurately detected Salmonella species with a higher degree of sensitivity and greater rapidity than the conventional PCR assay, and it may be suitable for point-of-care testing in the field. To detect Salmonella at the early stage of infection, a sensitive and reliable method is crucial. Various methods have been developed for Salmonella detection using molecular tools such as direct polymerase chain reaction (PCR) and multiplex quantitative PCR [6] . A PCR-based assay is currently the most commonly used tool for molecular screening of Salmonella [7] . However, PCR methods require specialized equipment that must be optimized for the amplification of target genes from samples, along with the extraction and purification steps carried out by a well-trained individual. Several technical issues such as long reaction times (about 2 h) and the requirement for well-purified nucleic acid are drawbacks for clinical application in many real-world settings. The lack of hardware resources in the field constitutes a critical barrier to the detection of pathogens directly from clinical samples [8] . Taken together, the limitations of conventional PCR-based methods make these assays difficult to use for point-of-care testing (POCT). POCT is a new concept in the laboratory-medicine discipline that enables screening for pathogens at the site where the infection occurs without transporting the test materials to well-equipped laboratories; by obviating the need for transport, POCT would be helpful to reduce the time necessary for clinical decision-making [9, 10] . Therefore, POCT requires fast reaction time and simple equipment. Loop-mediated isothermal amplification (LAMP) technology, an isothermal nucleic acid amplification method developed by Notomi et al. [11] , can amplify target nucleic acids at a consistent temperature without changing the temperature for PCR cycling. The LAMP assay has been proven to be an effective tool for POCT in the field to test for infectious diseases [12] [13] [14] . There are several advantages of the LAMP technology. First, due to isothermal amplification, LAMP does not need a thermal cycler; therefore, this technology is ideal for POCT in the field. Second, the reaction time is much shorter than that of PCR, which is advantageous for rapid testing of highly contagious infections and preventing the spread of infections at an early stage. Third, the detection sensitivity of LAMP is higher than that of conventional PCR due to the loop-mediated amplification strategy. Fourth, LAMP is relatively less sensitive to PCR inhibitors, which can contaminate samples from sources such as feces; therefore, LAMP would be advantageous for minimizing the sample preparation procedure. During the LAMP reaction, the inner primers anneal by Watson-Crick complementarity to a region within the target and a hybridized loop structure is generated by strand invasion, which allows more efficient amplification for the synthesis of large amounts of DNA in a short time [11] . Several studies have reported LAMP assays targeting Salmonella in food [15, 16] . The invA gene has been the most frequent target for Salmonella detection LAMP assays [15] . In this study, we aimed to develop a real-time LAMP assay targeting the hilA gene for uni-versal detection of Salmonella species. We also validated the LAMP assay with seven clinically important Salmonella pathogens. In this study, seven major Salmonella species were used. Six species (Salmonella Typhi, Salmonella Typhimurium, Salmonella enteritidis, Salmonella Paratyphi A, Salmonella Paratyphi B, and Salmonella Infantis) were collected from the Korea National Institute of Health (KNIH), Republic of Korea. Salmonella enterica was collected from Chungbuk Veterinary Service Laboratory, Chungju, Republic of Korea. For the specificity test, we used 11 non-Salmonella pathogens: seven Gram-negative and four Gram-positive bacteria ( Table 1) . All Salmonella strains (n = 7) were cultivated for 24 h at 37°C on sheep blood agar (Bandio, Pocheon, Korea). Non-Salmonella strains (n = 11) were cultivated for 36 hours at 37°C on Difco Luria-Bertani agar (BD, Franklin Lakes, NJ, USA). DNA extraction was done via QlAamp DNA Mini kit (Qiagen, Germantown, MD, USA) according to the manufacturer's instructions using the proto- col. For Gram-negative bacteria, colonies on the freshly cultured bacteria were added to the ATL buffer (180 μL) containing proteinase K (20 μL; 20 mg/mL) and suspension. The sample was then mixed by vortexing and incubated at 56°C until the bacteria were completely lysed. Next, 200 μL of lysis buffer was added to each sample and incubated at 70°C for 10 min. Then, vortexing for 15 seconds was performed right after adding 200 μL of ethanol. The mixture was transferred to the QlAamp Mini Spin column and centrifuge at 6,000 × g for 1 min. The genomic DNA in the spin column was washed using 500 μL of AW1 buffer and centrifuged at 6,000 × g for 1 min. Next, 500 μL of AW2 buffer was added and centrifuged at 20,000 × g for 3 min. For the elution process, 100 μL of distilled water was added and centrifuged at 6,000 × g. The genomic DNA was measured using Qubit 3.0 Fluorometer (Thermo Fisher Scientific, Waltham, MA, USA) and the DNA was stored at -20°C for further study. Gram-positive bacteria were added to 180 μL of lysis buffer containing proteinase K (20 μL; 20 mg/mL) and incubated for 30 min at 37°C instead of using the ATL buffer. The other steps were the same as in the protocol for Gram-negative bacteria. Primer Explorer V4 (http://primerexplorer.jp/elamp4.0.0/index. html) was used to design Salmonella species LAMP primers. The three sets of primers included a forward outer primer (F3), a backward outer primer (B3), a forward inner primer (FIP), a backward inner primer (BIP), and two loop primers: a forward loop primer (LF) and a backward loop primer (LB). All sets of primers were then validated by the BLAST program. Of the three sets of LAMP primers, the set that demonstrated the best amplification performance was selected as the Salmonella LAMP primer set (Fig. 1 ). The LAMP reaction was carried as described elsewhere with some modifications [17] . In brief, a 20 μL reaction mixture was prepared that contained 1 μL of target genomic DNA along with 1. To optimize the amplification conditions, the LAMP reaction was performed at different temperatures (60°C-65°C). To evaluate the detection sensitivity of the LAMP assays, we tested the detection limit using S. enterica DNA, which was 10-fold serially diluted from 1 ng to 1 ag and used in the LAMP reaction. To test for non-specific amplification of non-Salmonella pathogens, we conducted the LAMP assay with seven non-Salmonella Gram-negative and four Gram-positive bacteria. Six LAMP primers were designed targeting the hilA gene as a universal marker of Salmonella species: two outer primers (F3 and B3), two inner primers (FIP and BIP), and two loop primers (LF and LB) (Fig. 1) . Validation of the primer set was performed using S. enterica DNA under standard LAMP conditions (60°C for 45 min) (Fig. 2) . We performed the LAMP reaction with four different combinations of primers. Set 1 involved LAMP with two inner and two outer primers but without a loop primer, set 2 used the set 1 primers with one loop primer (LB), set 3 used the set 1 primers with another loop primer (LF), and set 4 used all six primers (Fig. 2) . As expected, LAMP without the two loop primers showed the slowest ampli-fication reaction. LAMP with one loop primer showed a faster amplification reaction than LAMP without any loop primer. LAMP with all six primers, including two loop primers, showed the fastest amplification reaction, in which a fluorescent signal appeared just 12 min after starting the reaction. None of the negative controls showed a positive signal during the reaction. Therefore, we decided to include all six primers in our Salmonella species LAMP system. To determine the best LAMP conditions, we compared three different reaction conditions: 60°C, 63°C, and 65°C for 45 min (Fig. 3) . Consistent with the results in Fig. 2 , LAMP with all six primers including two loop primers showed the fastest amplification reaction regardless of reaction temperature. Regarding the reaction conditions, a reaction temperature of 60°C showed the best amplification performance. Integrating these, we set the conditions for our Salmonella LAMP assay as using all six primers at 60°C for 45 min. To test the detection sensitivity of our Salmonella LAMP assay, we observed the limit of detection (LOD) of this assay. Salmonella enterica DNA was 10-fold serially diluted from 1 ng to 1 ag and used in the LAMP reaction (Fig. 4) . The LOD of the Salmonella LAMP assay was 100 fg which corresponds to 20 copies of Salmonella DNA. The time for the fluorescent signal to appear from 1 ng of template DNA was less than 20 min. Even in the case of 1 pg of To validate whether our universal Salmonella LAMP assay can detect diverse Salmonella species, we prepared seven clinically important Salmonella species (S. Typhi, S. Typhimurium, S. Enteritidis, S. enterica, S. Paratyphi A, S. Paratyphi B, S. Infantis) and used them with this assay (Fig. 5 ). All seven Salmonella species showed specific amplification signals at around 15 min except S. Paratyphi A. In contrast, the negative control did not show any amplification signal. To verify the Salmonella-specific detection, we also conducted our Salmonella LAMP assay with 11 non-Salmonella pathogens (seven Gram-negative and four Gram-positive bacteria) ( Table 1) . None of the non-Salmonella pathogens showed any amplification signal with our Salmonella LAMP assay (data not shown). In this study, to develop a real-time LAMP assay for the rapid and sensitive detection of Salmonella species, we designed a LAMP primer set targeting the hilA gene. The hilA gene, a member of the transcriptional regulator genes encoded in the Salmonella pathogenicity island 1 (SPI1), plays an important role in the pathogenesis of Salmonella infection by activating the expression of SPI1 [18, 19] . SPI1 is one of the key virulence factors for Salmonella infection and invasion. The hilA gene is known to be Salmonella species-specific and absent in other Gram-negative bacteria [20] . Therefore, this gene has been targeted for detecting Salmonella infection by PCR [21] . However, no study has yet developing a LAMP assay targeting the hilA gene for the detection of Salmonella species. In the LAMP assay, a high level of amplification efficiency can be achieved under isothermal conditions due to strand displacement by the Bst DNA polymerase enzyme [11] . However, the possibility of non-specific amplification is also high due to the high level of amplification. To minimize this possibility, we added NMF and IBA as described previously [17] . In addition, we optimized the LAMP reaction conditions to facilitate the efficient and reliable detection of Salmonella species. When we checked the detection sensitivity of our Salmonella LAMP assay using S. enterica DNA, the LOD was 100 fg, which corresponds to just 20 copies of Salmonella DNA. In the previous PCR assay targeting the hilA gene using S. typhimurium DNA, the LOD was 100 pg [21] . Therefore, although the Salmonella strains used for the sensitivity test were different, our Salmonella LAMP assay is approximately 1,000 times more sensitive than the PCRbased assay to detect Salmonella species. Of note, when we tested whether our universal Salmonella LAMP assay can detect diverse Salmonella species, all seven Salmonella species (including S. Typhimurium) showed consistent detection performance, providing further support that our Salmonella LAMP assay is much more sensitive than the PCR assay. This result also suggests that this Salmonella LAMP assay is universally applicable for the detection of diverse clinically important Salmonella species. When we tested the assay using 11 non-Salmonella pathogens, none of them showed any amplification signals with our Salmonella LAMP assay, suggesting high Salmonella species specificity of our LAMP assay. According to the BLAST (https:// blast.ncbi.nlm.nih. gov/Blast.cgi) analysis, none of the 11 non-Salmonella pathogens showed similar sequences to the hilA gene (data not shown). Of particular note, a previous study based on the conventional PCR method targeting the hilA gene took approximately 1 hour and 45 minutes [21] . However, all Salmonella species tested in this study showed specific amplification signals at around 15 minutes except S. Paratyphi A, demonstrating that our Salmonella LAMP assay would be ideal for POCT. One of the fundamental limitations of conventional PCR is that PCR is easily inhibited by substances in the sample. LAMP technology can overcome this drawback of PCR, as LAMP is relatively less sensitive to PCR inhibitors, which can contaminate samples from sources such as feces. Therefore, LAMP would be advantageous to minimize the sample preparation procedure. In conclusion, our Salmonella LAMP assay targeting the hilA gene demonstrated a high level of sensitivity and specificity. Considering the higher sensitivity of our assay than conventional PCR, its rapid reaction time, and its lower sensitivity to potential PCR inhibitors, our assay could be a useful POCT tool for Salmonella species. Evolving public health approaches to the global challenge of foodborne infections Loop-mediated isothermal amplification (LAMP) for the detection of Salmonella in food Foodborne illness acquired in the United States: major pathogens Salmonella epidemiology: a whirlwind of change Detection of Salmonella spp. by a loop-mediated isothermal amplification (LAMP) method targeting bcf D gene Rapid detection and differentiation of Salmonella species, Salmonella Typhimurium and Salmonella Enteritidis by multiplex quantitative PCR Recombinase assisted loop-mediated isothermal DNA amplification Loop-mediated isothermal amplification (LAMP): an advanced molecular point-of-care technique for the detection of Leishmania infection Point-of-care testing (POCT): current techniques and future perspectives Point-of-care nucleic acid testing for infectious diseases Loop-mediated isothermal amplification of DNA Loop mediated isothermal amplification: a promising tool for screening genetic mutations Isothermal amplification of nucleic acids LAMP) assays as a rapid diagnostic for COVID-19 Loop-mediated isothermal amplification for Salmonella detection in food and feed: current applications and future directions Loop-mediated isothermal amplification for the rapid detection of Salmonella Development of reverse transcription loop-mediated isothermal amplification assays for point-of-care testing of avian influenza virus subtype H5 and H9 Identification and characterization of mutants with increased expression of hilA, the invasion gene transcriptional activator of Salmonella typhimurium AraC/XylS family members, HilC and HilD, directly bind and derepress the Salmonella typhimurium hilA promoter hilA is a novel ompR/toxR family member that activates the expression of Salmonella Typhimurium invasion genes Simple and rapid detection of Salmonella strains by direct PCR amplification of the hilA gene No potential conflict of interest relevant to this article was reported.