key: cord-0022045-s1y9sdy3 authors: Jiang, Yuping; Song, Juanjuan; Zhu, Andong title: Gas-phase advanced oxidation (GPAO) for benzene-containing gas by an ultraviolet irradiation/hydrogen peroxide vapour (UV/[H(2)O(2)](g)) process date: 2021-10-14 journal: Environ Sci Pollut Res Int DOI: 10.1007/s11356-021-16920-w sha: ab6b7de9fc65b808b19ac7c80048d691097804bc doc_id: 22045 cord_uid: s1y9sdy3 Hydrogen peroxide (H(2)O(2)) is a remarkably strong oxidant, and its vapour ([H(2)O(2)](g)) has further advantages, such as a low cost and good light transmission. However, there has been very little research on its removal through gas-phase advanced oxidation (GPAO). In the present study, the photochemical oxidation of a gas that contains a series of benzene derivatives using ultraviolet (UV) irradiation and [H(2)O(2)](g) was investigated in a transparent bag made of fluorinated ethylene propylene (FEP). UV and [H(2)O(2)](g) barely reduced the pollutant within 5 h when used alone, and the reactant was also stable. When the pollutant concentration was high (248 to 756 mg/m(3)) and the residence time was short (3 s) compared with related studies on the removal of benzene, toluene and xylene, the apparent removal rate by UV/[H(2)O(2)](g)/(powder active carbon, PAC) was higher than when other methods (UV/[H(2)O(2)](g), UV/[H(2)O(2)](g)/TiO(2) and UV/[H(2)O(2)](g)/ZnO), were used. However, it was found that the mineralization by UV/[H(2)O(2)](g) significantly decreased, which in turn decreased the conductivity after the reaction. Increasing the pollutant concentration and the pH of the H(2)O(2) had a negative effect on the treatment, but the UV radiation had a positive effect at powers of up to 40 W. In addition, the characteristic absorbance of three benzene derivatives showed that the key structure of the pollutant molecules was damaged during GPAO. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11356-021-16920-w. People need to breathe constantly, so nobody can avoid the influence of pollution. However, it is a widely recognized reality that air quality is not always good, especially in developing countries. Thus, pollution removal methods are increasingly studied. Such air pollution removal methods include adsorption, absorption, advanced oxidation (AO) and so on. Compared with other treatment methods, AO results in more complete and quicker removal of pollutants. Photochemical methods that do not require catalysts have received more attention in recent years (Alapi et al. 2007; Mo et al. 2009; Zhang and Anderson 2013) because there are some distinctive advantages, such as energy efficiency and running costs, that must be evaluated for real-world applications (Matthew et al. 2014) . Both hydrogen peroxide and ozone are well-known oxidants that are usually used in aqueous and gaseous systems, respectively (Wang and Ray 2000) . Although ozone is probably the leading oxidant species because its 2.07 V oxidation-reduction potential (ORP) is higher than that of hydrogen peroxide 1.8 V, both substances can produce the •OH radical, which is regarded as the key oxidant in the AO process. Furthermore, H 2 O 2 has multiple benefits. First, it is very easy to generate as long as electron donors are present in water, and chromophoric substances can produce hydrated electrons by illumination and combine with dissolved oxygen, which leads to a series of reactions for H 2 O 2 outcome (Anastasio et al. 1997; Wohlgemuth et al. 2001) . Second, artificial production of hydrogen peroxide is very convenient, even in situ production ( Choudhary and Jana 2007; Fang et al. 2013) . Third, H 2 O 2 can be used as an indicator in the AO process because the representative oxidant, the hydroxyl radical (•OH), which has an (oxidation reduction potential) ORP of 2.8 V, can lead to H 2 O 2 formation by reacting with volatile organic compounds (VOCs), CO, SO 2 , and other pollutants. It is evident that in AO involving multiple radical chain reactions, hydrogen peroxide plays a central role (Möeller 2009 ). Due to its unique properties, H 2 O 2 is usually used as an oxidative solution in tandem with ultraviolet (UV) radiation in AO processes to remove liquid pollutants Muruganandham and Swaminathan 2004) . Because the reactants are in solution during this process, the waste has a long residence time. For gas pollutant treatment, some studies have shown that UV/H 2 O 2 can oxidize SO 2 , NOx and Hg 0 at low concentrations in flue gas (Yangxian et al. 2011; Yangxian et al. 2014) . However, research focusing on GPAO by [H 2 O 2 ] g is very rare, especially that which involves a high pollutant concentration and short residence time, even if the vapour is only used for sterilization (French et al. 2004) . In reality, the vapour form of H 2 O 2 not only maintains the properties of the solution phase but also provides some advantages, such as a lesser oxidant consumption and decreased loss of UV light that passes through the reaction system. In this work, the GPAO by H 2 O 2 vapour was studied to understand the effect of harsh conditions, such as high concentration pollution and short residence time compared with those of related studies. The experiment was conducted to investigate the decomposition of benzene, toluene and xylene by UV/[H 2 O 2 ] g . The reactions took place in a transparent bag made of fluorinated ethylene propylene (FEP, Teflon) due to its high reactive inertia and UV transmittance (Du et al. 2007) . Benzene derivatives were chosen as the target compounds because such organic pollutants, including benzene, toluene and xylene, are frequently encountered, for example, benzene and toluene are frequently encountered in indoor and outdoor environments (Wallace et al. 1993; Bernstein et al. 2008) , are representative organic contaminants (Liu et al. 2016 ) and can cause multiple diseases in humans. Research on pollutant removal methods includes adsorption, evaporation, membrane separation, microbial degradation and catalysis (Liu et al. 2018; Miaralipour et al. 2017; Varjani et al. 2017) . However, GPAO is rarely used (Zhang et al. 2003; Johnson et al. 2014) , and studies using H 2 O 2 as an oxidant have not been reported. The reagents were used as received without further treatment. Benzene, toluene, xylene, NaOH, HCl and 30% commercial H 2 O 2 solution (Guoyao Chemical Reagent Co., China) were analytical-grade reagents (AR). The powdered active carbon (PAC, < 75 μm diameter, 0.45 g/cm 3 ), ZnO (5.6 g/cm 3 ) and TiO 2 (4.28 g/cm 3 , anatase) powder with a diameter of 20 nm and purity of 99.9% were separately purchased from Liyang Nanfang Activated Carbon Factory, Brofos Nanotechnology Ningbo Co., China. The experimental system used in this study is illustrated in Fig. 1 . All gas flow channels in the experimental system were FEP pipes. In this procedure, equal quantities of PAC, TiO 2 and ZnO (2 g) were added into compartment D, and air was pumped by a micro air pump (ACO-001, Guangzhou Weierma Instrument Co., Ltd. China) into the FEP pipes, regulated by rotameters to transfer the vapour of benzene and H 2 O 2 to D. Here, the gas was thoroughly mixed with the powder due to the small particle size and low density of the powder. Then, the mixture was transferred to the FEP bag and irradiated under a UV lamp to undergo a To determine the apparent removal rate (dependent on the measurement for the pollutants), the pollutant concentrations were monitored via gas chromatography (GC) with FID and an AB-INOWAX fused silica capillary column (sampling time of 50-90 min). The retention time was 1.2-1.6 min and was calculated by Eq. (1); the mineralization rate, which was dependent on the measurement of the terminal degradation product, was calculated with measurements from a CO 2 detector (GT-1000-CO 2 , KORNO Co. Ltd. China). The characteristic absorbance of the pollutants and [H 2 O 2 ] g was determined by UV-vis spectroscopy and H 2 O 2 detector (GT-1000-H 2 O 2 , KORNO Co. Ltd. China) separately. The apparent and mineralization efficiencies were calculated using Eqs. (2) and (3), respectively. where A is the peak area of the waste concentration determined by GC, and the correlation coefficient for (1) is 0.9997; C is the concentration of the benzene derivative in mg/m 3 ; C in,p and C out,p are the inlet and outlet concentrations of pollutants, respectively; C in,c and C out,c are the CO 2 concentrations; and C T,c is the total CO 2 concentration upon complete oxidation of the pollutant. To investigate the effect of pH and conductivity, the pH of the H 2 O 2 solution was adjusted by adding HCl and NaOH and was determined using an acidimeter (Model Starter 2100/3C Pro, Shanghai Hongji Instrument Co., Ltd. China). After 1 h of absorption in a 25-mL opaque sampling tube with pure water, the conductivity was measured using a Conductivity Meter (DDSJ-319L, INESA Scientific Instrument Co., Ltd. China). Benzene was used as the target compound in these experiments. Figure 2 shows that with a maximum UV radiation power of 30 W, benzene is resistant to removal under different reaction times, and the apparent removal rate was in the range of 0.5-1%. There was little direct UV photo-oxidation and that which occurred was indirectly caused by substances in the ambient air, such as O 2 and H 2 O. This observation is in accordance with studies showing that toluene and benzene in air could hardly be degraded under > 200 nm UV light (Zhang et al. 2003; Zhuangzhuang et al. 2019 ) because 253.7 nm is too long of a wavelength to break the benzene molecular bond because the photons do not have enough energy. Although dimethylbenzene could be reduced under 254 nm light after a long time (> 3 h) (Ma et al. 2007) , the substance is different from the benzene derivatives used in this study. In addition, it is critical to understand the impact of the reactor walls on gas-phase reactivity; due to the background NOx off-gas and other reactive species, heterogeneous reactions can generate "chamber radical sources" upon irradiation (Carter et al. 1982) . However, Fig. 2 shows that the effects did not effectively influence pollutant reduction under certain conditions. The experimental conditions were as follows: benzene concentration: 455 mg/m 3 ; gas flow: 9 L/min; reactant temperature (room temperature): 25 °C; UV energy: 30 W; and residence time: 3 s. The performance of benzene oxidation with only [H 2 O 2 ] g was investigated without UV radiation. Figure 3 shows that the pollutant quantity decreased very slightly (≤ 2%) over 5 h of reaction time; this result implies that although ambient light with very weak ultraviolet radiation could be transmitted into the reactor to cause [H 2 O 2 ] g to release ·OH, the production of free radicals was too rare to enhance the reaction. Thus, the benzene was extremely inert and was not easily degraded by [H 2 O 2 ] g oxidation. This phenomenon also suggested that Other studies have proven that FEP Teflon bags meet the requirements of accuracy and small loss of gas due to photochemical reactions under different humidity, illumination, and substance conditions (Jia et al. 2011; Jia and Xu. 2014; Li et al. 2021) . Therefore, based on the results of the test mentioned above, the reactor satisfactorily met the requirements of the study. However, Fig. 3 showed that after 3 h of treatment, the removal of benzene was the highest (2%), while 5 h of treatment resulted in a lower inefficiency (0.5%). According to the observations in this work, [H 2 O 2 ] g formed by 30% solution could slowly accumulate in the FEP pipe (not transparent) and bag (transparent). Therefore, when accumulation initially occurred in the pipe, the rate remained stable due to a lack of additional ·OH production in the reactor; then, when the accumulative H 2 O 2 reached the bag, radicals could be generated to slightly enhance the reaction. However, with the increase in the substances accumulated on the bag wall, the transmission of the weak light was easily hindered, resulting in the subsequent decrease in the efficiency. After the reaction, the accumulation measurement for H 2 O 2 was also carried out (Supplementary Information in Fig. S5 ). The experimental conditions were similar to those in the "Apparent removal by UV radiation" section, in which 4.6 mol/m 3 [H 2 O 2 ] g was used to replace the UV light. All four treatment methods could reduce the contaminants, as shown in Fig. 4 . Although the maximal efficiency was 31% for toluene, which is lower than that reported in related research (Yangxian et al. 2014; Xu et al. 2007 ), the toluene was obtained with a very short residence time and high concentration of pollutants. Thus, the result was still very meaningful, as [H 2 O 2 ] g played an important role as an oxidant. The fundamental role of H 2 O 2 lies in its decomposition into.OH free radicals under UV radiation at a certain wavelength according to the following reaction (Lee et al. 2004 ). Then, the removal of pollutants can be expressed by the following equations ): The catalyst and PAC completely left in the process, the determination of departure time and the subsequent removal after that time were also carried out (Supplementary Information in Table S1 and Fig. S4 ). In these three pathways, the potential problem was that H 2 O in the H 2 O 2 vapour could hinder the removal because of its competitive adsorption onto the reaction surface of the contaminants (Herrmann et al. 1999; Nazir et al. 2003) . However, some promotion of removal occurred in the process. In addition to the •OH radical produced by H 2 O 2 , it was also produced by the two catalysts under 253.7 nm UV light. The electrons (e − ) in the electron-filled valence band could be excited by photoirradiation (hv > band gap energy) to the vacant conduction band, leaving a positive hole (h + ) in the valence band; this h + caused the OH − from H 2 O oxidation to produce •OH, as shown in Eqs. (7) and (8). Then, •OH could oxidize the compounds adsorbed on the surface of a photocatalyst. In addition, owing to the higher electron affinity of H 2 O 2 (1.8 eV) than that of O 2 (0.44 eV), the excited electrons in the conduction band could be captured by H 2 O 2 more easily than by O 2 , which increased the production of •OH. Although the particle size of the PAC was the largest, its lowest density ensured ideal uniformity of mixing, and the adsorption performance could be helpful for removing pollutants, although the benzene derivatives were not completely degraded. There were fewer negative impacts of TiO 2 and PAC than positive impacts, and the latter treatment is better for situations in which the adsorption surface area is very great. For the three pollutants, the desired enhanced effect of ZnO did not occur, but rather, the removal was less than when the other treatments were used. It was concluded that ZnO was prone to photocorrosion (Hoffmann et al. 1995; Han and Zhao 1999) , and its density was highest, which caused deposition, leading to the shortcomings caused instability and heterogeneity during the reaction. The experimental conditions were similar to those in the "Apparent removal by UV radiation" section, in which 4.6 mol/m 3 [H 2 O 2 ]g was also applied. In Fig. 5 , it is shown that xylene had the highest apparent removal and mineralization rates, and benzene had the lowest. Toluene and xylene have one and two methyl groups substituting the hydrogen on the benzene ring, respectively; this substitution weakens the stability compared with that of benzene. These exocyclic groups are points that are easily attacked by oxidative species, which leads to the destruction of the whole molecular structure. Due to the greater number of methyl substitutions, the removal rate of xylene was most remarkable. The results also showed that although the apparent removal rate was more than 10%, the mineralization was very low; the maximum was less than 5%. In general, the advanced oxidation by •OH can be expressed as Eq. (9). To remove the series of benzene derivatives, C = C or C-H were first cracked to form active organic radicals, and then the radicals continued to produce multiple fragments (intermediates), of which only some were oxidized to CO 2 and H 2 O; these observations were in accordance with those reported in multiple studies (Kuo-Pin and Grace 2007; et al. 2014 ). Due to the differences between the two measurement methods in this work, it was noted that most of the degraded pollutants did not mineralize, and the corresponding products were intermediates (not terminal degradation products), which caused a remarkable gap between the apparent removal and mineralization rates. For the other treatments with PAC and catalysts, similar results were also obtained (Supplementary Information in Fig. S1 -PAC, S2-TiO 2 and S3-ZnO). These phenomena also revealed the limitations of GPAO, which cannot completely remove contaminants, hence limiting its applications. The experimental conditions were in accordance with those described in the "Apparent removal using different methods" section. Due to the multiple intermediate GPAO products, it is meaningful and necessary to focus on the characteristics of the molecules to determine whether pollutant structures are damaged. For the benzene derivatives, the conjugated ethylene in the benzene ring plays a directive role, and UV-Vis was used to investigate the inlet and outlet differences of the indicator. Although the benzene derivatives had a B-absorption band (230-270 nm) and E2 band (200-210 nm), the latter intensity was always higher than the former. Thus, E2 was used as the maximum absorbance in the experiment, and only the results of UV/[H 2 O 2 ] g degradation are mentioned in Table 1 . These results show that the wavelength and absorption intensity of toluene and xylene are higher than those of benzene because there were redshifts and hyperchromic effects. It is believed that the methyl groups in the two pollutants are auxochromes, and their electrons in the n orbital can produce a conjugation effect with π electrons from the chromophores. Then, the electrons in the electron cloud can influence each other, which changes the absorption intensity and peak position (Li et al. 2010 ). Table 1 also shows that there was a higher absorbance for inlet pollutants than for outlet pollutants. This phenomenon proved that it is also a feasible way to determine the removal effect. In addition, although this method involves a clear response to the conjugated ethylene in the benzene ring, it is rarely used in GPAO because the low concentrations of pollutants in the sample solution lead to very weak absorption peaks; in this work, this problem was solved by increasing the initial pollutant concentration and ending collection after longer sampling times. The experimental conditions were in accordance with those in the "Apparent removal using different methods" section. In similar works, conductivity was not studied as the measurement index, although it can indicate changes in the substances after reaction. Figure 6 shows the conductivities of the inlet and outlet for removal of different pollutants. The data slightly decrease in the blank test (absorption by pure water), but opposite effects are observed with the pollutants. The result in the blank test could be explained by the fact that the UV decomposition of H 2 O 2 caused its ionization reduction. For the latter measurement, Martina et al. found that the increase in polar products had a positive correlation with conductivity (Hein et al. 1998 ); therefore, it was believed that intermediates such as aldehydes, ketones and alcohols were polar products accelerated by the reaction and could not be completely eliminated due to the limited retention time. In addition, the increased values for benzene, xylene and toluene were 3.6, 1.2 and 0.2, respectively. This result also indicated the difference in the quantity of polar intermediates, which is in accordance with some other studies (Kislov et al. 2004; Hamilton et al. 2005; Yu et al. 1997) . The experimental conditions were in accordance with those described in the "Apparent removal using different methods" section. Benzene vapour was selected to investigate the influence of pH. The effect on the waste removal efficiency is shown in Fig. 7 , in which the rate decreased from 28.6 to 1.7 as the H 2 O 2 solution pH increased from 4 to 9. It is widely recognized that H 2 O 2 has stronger oxidizing properties under acidic conditions; therefore, the degradation was reduced with increasing solution pH. For these reasons, some research has proven that H 2 O 2 in solutions can produce HO 2 − species, which scavenge ·OH radicals via a hydrolysis reaction (Meng-Wen and Chia-Chun 2010; Liu et al. 2011) . When the solution is alkaline, OH − can consume H + and accelerate HO 2 − formation. In addition, OH − can also consume ·OH radicals through the following reaction (Zehavi and Rabani 1971) , thereby reducing the removal efficiency of benzene: Conditions Aside from the pH, the experimental conditions were in accordance with those described in the "Apparent removal using different methods" section. The influence of UV radiation was investigated at different UV powers, as shown in Fig. 8 . The results show that the removal increases with increasing UV power at values from 10 to 40 W. The improvement between 30 and 40 W was less than at lower power levels, and no improvement was observed from 40 to 50 W. It could be deduced that the •OH concentration was increased when the UV intensity was increased; thus, the chain reactions were strengthened to obtain a higher reactant consumption rate (Anglada et al. 2002) . However, when the UV radiation power exceeded a certain value, several side reactions (reactions 13-16) also simultaneously occurred in the system, resulting in the loss of ·OH. Thus, with further increases in the light power to 40 W, the pollutant removal efficiency only increased slightly and then did not change at 50 W, which was the equilibrium state of the opposite action. (10) Conditions Aside from the UV light intensity, the other experimental conditions were in accordance with those described in the "Apparent removal using different methods" section. Under the same reaction conditions, benzene was used to study the effect of pollutant concentrations from 248 to 756 mg/m 3 in the experiments. As shown in Fig. 9 , the removal efficiency decreased when the initial concentration of benzene was increased. For a single chemical reaction system, according to the general theory, increasing the reactant concentration can raise the rate. However, in the photochemical reaction, improving the removal required more oxidants for degradation, and the higher oxidant concentrations were increasingly obstructive to UV radiation, causing the. OH to only be irradiated by a smaller amount of UV light, which led to the formation of fewer free radicals (Aleboyeh et al. 2005) . Thus, the rate decreased. Conditions Aside from the pollutant concentration, the other experimental conditions were in accordance with those (13) 2 2 + • → 2 • + 2 (14) • + • → 2 2 (15) 2 • + 2 • → 2 2 + 2 (16) • + 2 • → 2 + 2 Fig. 8 Influence of UV power for benzene removal Fig. 9 Influence of concentration on benzene removal described in the "Apparent removal using different methods" section. The reaction system, which included a reactor made of FEP film, [H 2 O 2 ] g as an oxidant, and UV light, was stable in the study and could also remarkably remove the benzene derivatives. In the present work, the reaction conditions were unfavourable compared with the conditions used in related studies. In particular, this study used shorter residence times and higher pollutant concentrations; thus, it was expected that with increasing reaction time, satisfactory efficiency would be obtained. In addition, it was very important to ensure the stability of the H 2 O 2 , pollution load and light transmittance; therefore, enhancing the power of the UV light and reducing the pH of the H 2 O 2 solution and the pollutant concentration could improve the treatment effect in the experiment. In the GPAO experiments, although the characteristic structures of the benzene derivatives were destroyed, there were multiple intermediate polar products that caused the apparent removal rate to be much higher than the mineralization rate. Thus, it is necessary to further research the complete removal of waste. The online version contains supplementary material available at https:// doi. org/ 10. 1007/ s11356-021-16920-w. Direct vuv photolysis of chlorinated methanes and their mixtures in a nitrogen stream The effect of operational parameters on UV/H 2 O 2 decolourisation of acid blue 74 Aromatic carbonyl compounds as aqueous-phase photochemical sources of hydrogen peroxide in acidic sulfate aerosols, fogs, and clouds. 1. nonphenolic methoxybenzaldehydes and methoxyacetophenones with reductants (phenols) Atmospheric formation of OH radicals and H 2 O 2 from alkene ozonolysis under humid conditions The health effects of non-industrial indoor air pollution Experimental investigation of chamber-dependent radical sources Dye decomposition kinetics by uv/h2o2: initial rate analysis by effective kinetic modelling methodology In situ generation of hydrogen peroxide from reaction of O 2 with hydroxylamine from hydroxylammonium salt in neutral aqueous or non-aqueous medium using reusable Pd/Al 2 O 3 catalyst Smog chamber simulation of atmospheric photochemical reactions of acetylene and NOx Superoxide mediated production of hydroxyl radicals by magnetite nanoparticles: demonstration in the degradation of 2-chlorobiphenyl Tackling contamination of the hospital environment by methicillin-resistant staphylococcus aureus (mrsa): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination Quantifying small molecules in secondary organic aerosol formed during the photo-oxidation of toluene with hydroxyl radicals Progress in applied research of the heterogeneous photocatalysis on semiconductors Determination of total polar parts with new methods for the quality survey of frying fats and oils Solar photocatalytic degradation of 4-chlorophenol using the synergistic effect between titania and activated carbon in aqueous suspension Environmental applications of semiconductor photocatalysis Studies of ozone formation potentials for benzene and ethylbenzene using a smog chamber and model simulation Characterization of photochemical smog chamber and initial experiments Gas-phase advanced oxidation for effective Photodissociation of benzene under collision-free conditions: an ab initio/rice-ramsperger-kassel-marcus study Decomposition of gas-phase toluene by the combination of ozone and photocatalytic oxidation process Kinetics and mechanisms of dmso (dimethylsulfoxide) degradation by UV/H 2 O 2 process Study on the characteristic UV absorption parameters of dissolved organic matter extracted from chicken manure during composting A large-scale outdoor atmospheric simulation smog chamber for studying atmospheric photochemical processes: characterization and preliminary application Study on the kinetics of no removal from simulated flue gas by a wet ultraviolet/H 2 O 2 advanced oxidation process Oxidation of benzene by persulfate in the presence of Fe(III)-and Mn(IV)-containing oxides: stoichiometric efficiency and transformation products Membrane materials in the pervaporation separation of aromatic/aliphatic hydrocarbon mixtures-a review Degradation of xylene in gas phase by ozone and UV light Gas-Phase Advanced Oxidation for Effective, Efficient in Situ Control of Pollution Dye decomposition kinetics by UV/ H 2 O 2 : initial rate analysis by effective kinetic modelling methodology TiO 2 /porous adsorbents: recent advances and novel applications Photocatalytic purification of volatile organic compounds in indoor air: a literature review Atmospheric hydrogen peroxide: evidence for aqueous-phase formation from a historic perspective and a one-year measurement campaign Photochemical oxidation of reactive azo dye with UV-H 2 O 2 process Photocatalytic degradation of gaseous ammonia and trichloroethylene over TiO 2 ultrafine powders deposited on activated carbon particles Comprehensive review on toxicity of persistent organic pollutants from petroleum refinery waste and their degradation by microorganisms Personal exposures, indooroutdoor relationships, and breath levels of toxic air pollutants measured for 355 persons in new jersey Application of ultraviolet photooxidation to remove organic pollutants in the gas phase Photochemical formation of hydrogen peroxide in atmospheric droplets: the role of iron, oxalate, and trace metals of the H 2 O 2 -production Photochemical degradation of diethyl phthalate with UV/H 2 O 2 Kinetic model of NO removal from SO 2 -containing simulated flue gas by wet UV/H 2 O 2 gasphase advanced oxidation process Photochemical oxidation removal of Hg0 from flue gas containing SO2 /NO by an ultraviolet irradiation/hydrogen peroxide (UV/H2O2) Process Atmospheric photooxidation of alkylbenzenes-i. carbonyl product analyses Pulse radiolytic investigation of O aq -radical ions Kinetic analysis of the photochemical decomposition of gas-phase chlorobenzene in a uv reactor: quantum yield and photonic efficiency photocatalytic degradation of low level toluene in the gas phase Experimental study of the secondary organic aerosol formed from the aqueous photooxidation of benzene The authors would like to thank the support by the Zhongshan Science and Technology Project (2019B2015) during the practical part of this work.Author contribution Yuping Jiang analysed and interpreted the experiment and data of present study and was a major contributor in writing the manuscript; Juanjuan Song review the content of the article; Andong ZHU prepared the instrument for the experiment. All authors read and approved the final manuscript.