key: cord-0019953-lzy6j9ep authors: Arellano-Pérez, Óscar; Castillo Merino, Felipe; Torres-Tejeiro, Roberto; Ugarte Ubiergo, Sebastián title: An assessment of esophageal balloon use for the titration of airway pressure release ventilation and controlled mechanical ventilation in a patient with extrapulmonary acute respiratory distress syndrome: a case report date: 2021-08-17 journal: J Med Case Rep DOI: 10.1186/s13256-021-02984-2 sha: 3ccbebb897f74b9e1b2baa0d72f15cf69a7e25b7 doc_id: 19953 cord_uid: lzy6j9ep BACKGROUND: Esophageal pressure measurement is a minimally invasive monitoring process that assesses respiratory mechanics in patients with acute respiratory distress syndrome. Airway pressure release ventilation is a relatively new positive pressure ventilation modality, characterized by a series of advantages in patients with acute respiratory distress syndrome. CASE PRESENTATION: We report a case of a 55-year-old chilean female, with preexisting hypertension and recurrent renal colic who entered the cardiosurgical intensive care unit with signs and symptoms of urinary sepsis secondary to a right-sided obstructive urolithiasis. At the time of admission, the patient showed signs of urinary sepsis, a poor overall condition, hemodynamic instability, tachycardia, hypotension, and needed vasoactive drugs. Initially the patient was treated with volume control ventilation. Then, ventilation was with conventional ventilation parameters described by the Acute Respiratory Distress Syndrome Network. However, hemodynamic complications led to reduced airway pressure. Later she presented intraabdominal hypertension that compromised the oxygen supply and her ventilation management. Considering these records, an esophageal manometry was used to measure distending lung pressure, that is, transpulmonary pressure, to protect lungs. Initial use of the esophageal balloon was in a volume-controlled modality (deep sedation), which allowed the medical team to perform inspiratory and expiratory pause maneuvers to monitor transpulmonary plateau pressure as a substitute for pulmonary distension and expiratory pause and determine transpulmonary positive end-expiratory pressure. On the third day of mechanical respiration, the modality was switched to airway pressure release ventilation. The use of airway pressure release ventilation was associated with reduced hemodynamic complications and kept transpulmonary pressure between 0 and 20 cmH(2)O despite a sustained high positive end-expiratory pressure of 20 cmH(2)O. CONCLUSION: The application of this technique is shown in airway pressure release ventilation with spontaneous ventilation, which is then compared with a controlled modality that requires a lesser number of sedative doses and vasoactive drugs, without altering the criteria for lung protection as guided by esophageal manometry. Esophageal pressure (Pes) measurement is a minimally invasive monitoring method used to assess respiratory mechanics in acute respiratory distress syndrome [1] . Pes tracings can be used to understand, define, and individually assess the physiopathological mechanisms of respiratory insufficiency and monitor the patient's clinical progression [1] . The first generation of customized esophageal balloons was mainly used for research purposes. Over the past decade, several kinds of second-generation balloons have been developed and are currently available for clinical use [1] . Esophageal balloon catheters can be connected to specific monitoring devices, such as pressure ports, mechanical ventilator accessories, or multiparametric monitor pressure transductors [1] . This kind of additional information can be useful in the case of pathologies such as acute respiratory distress syndrome (ARDS), which is characterized by acute respiratory insufficiency with bilateral shadowing on thorax X-rays, pulmonary edema that cannot be completely explained by cardiac insufficiency or excess lung liquid, and hypoxemia with a PaO 2 / FiO 2 ratio < 300 with positive end-expiratory pressure (PEEP) higher or equal to 5 cmH 2 O [2] . Despite the usefulness of esophageal pressure monitoring, clinical reports are still scarce, and its use in unconventional modalities is experimental and mainly used in research. To better clarify the usefulness of Pes measurements in a clinical context, we will assess the technical, physiological, and clinically relevant details of this monitoring method to facilitate an improved understanding of the information provided by bedside Pes measurements. Airway pressure release ventilation (APRV) was first described and introduced to clinical practice over 20 years ago and was made commercially available by the mid 1990s [3, 4] . It is a relatively new positive pressure ventilation modality and has a series of advantages over low tidal volume assisted ventilation in ARDS patients [5] . Its benefits are mainly related to spontaneous respiration, which improves both patient-ventilator synchronization and the ventilation-to-perfusion ratio, thus improving gas distribution into dependent lung regions [6] . The patient was a 55-year-old chilean female, with preexisting hypertension and recurrent renal colic who entered the cardiosurgical intensive care unit (ICU) with signs and symptoms of urinary sepsis secondary to a right-sided obstructive urolithiasis. Upon admission, the patient showed signs of urinary sepsis, a poor overall condition, hemodynamic instability, tachycardia, hypotension mean arterial pressure (MAP) 70, and required vasoactive drugs. A general physical examination showed signs of consciousness and a Richmond Agitation-Sedation Scale (RASS) score of −1 to 0. The patient had petechiae on her upper torso and lower limbs; an apparently Fig. 1 ). The patient was treated with volume control ventilation. A lung recruitment maneuver was performed following a first arterial blood gas test (ABGs) ( Table 2 , Day 0, first rounds), as oxygenation following the intervention was inadequate ( [2] . However, pressure on the airway was reduced owing to hemodynamic complications ( Table 2 , day 1 first round to day 2 fourth round). During the patient's second day on mechanical ventilation, she showed intraabdominal hypertension [intraabdominal pressure (IAP) 18 mmHg] that compromised the oxygen supply and her ventilation management (Table 2 , day 2, second and third rounds). Consequently, an esophageal manometry was taken to measure lung distention [that is, transpulmonary pressure (TPP); 7] and protect the patient's lungs. Initial use of the esophageal balloon volume-controlled in deep sedation allowed the medical team to perform inspiratory and expiratory pause maneuvers to monitor transpulmonary pressure during end inspiration (PLend-insp) and transpulmonary pressure during end expiration (PLend-exp) ( Table 3 , Day 2, fourth and fifth rounds). In line with the literature on esophageal manometry catheter use, our aim was to attain a PLend-insp below 20 cmH 2 O, as part of the lung enters full regional pulmonary capacity at this point [8] . The AVEA (Care Fusion) ventilator's esophageal manometry system was used, following a test of the balloon and pressure measurement calibration. The catheter was then inserted through the nasal passage to approximately 55 cm, in line with the available literature [9] , until reaching optimum gastric position, before being inflated to a suitable volume so measurements would remain unaltered. The catheter's intragastric placement was checked by means of positive pressure deviation under gentle external manual epigastric compression [1] . The balloon was then removed until cardiac activity was visible in the esophageal pressure reading, indicating that the pressure measuring location was in the bottom third of the esophagus. Since the Pes measurement [7] did not seem to be significantly affected by the presence of a nasogastric tube, the patient was also given a nasojejunal probe. An occlusion test (Baydur test) [10] was performed to determine the accurate measurement of the esophageal balloon. A 20 cmH 2 O PEEP was initially established to maintain a 0 and 2 cmH 2 O PLend-exp (Fig. 2) . However, hemodynamic deterioration made it necessary to establish a PEEP of up to 16 cmH 2 O, leading to a −2 and −1 PLendexp (Figs. 3, 6A). On the third day of mechanical ventilation, the modality was switched to APRV (PEEP high of 20 cmH 2 O and low of 10 cmH 2 O, peak timing of 3.1 seconds, Fig. 1 A Thoracic X-ray on first day in intensive care unit / B Thoracic X-ray on third day in intensive care unit 0.6 seconds expiratory time, 16 revolutions per minute mandatory respiratory frequency, and 80% FiO 2 ), which allowed for lower sedation levels, from -5 to −3 RASS, from the suspension of continuous midazolam infusion (Fig. 4) . The decision to use the APRV modality was related to an improvement in cardiac function, a rise in the cardiac index to above 4.1 L/minute/m 2 even after suspending dobutamine infusion (Fig. 5B) , and hemodynamic improvement. This allowed for the suspension of continuous noradrenaline infusion, while levels of indexed systemic vascular resistance were kept between 1070 and 1860 dinas-seg-m 2 /cm 5 (Fig. 5A) . The indexed intrathoracic blood volume during APRV varied between 999 and 1335 ml/m 2 . As described above, during controlled ventilation in parallel with hemodynamic complications, it was not possible to titrate the necessary PEEP to maintain transpulmonary pressure above 0 cmH 2 O (Fig. 3) . However, the use of APRV was associated with reduced hemodynamic complications (Fig. 5) and kept the PLendexp between 0 and 20 cmH 2 O despite a sustained PEEP high of 20 cmH 2 O (Fig. 6) . Following the start of Pes monitoring and APRV, the patient's PaO 2 , PaO 2 /FiO 2 ratio, and oxygenation index all varied less than they had under the controlled modality (Fig. 7) . The P-high was adjusted to 2 cmH 2 O over plateau pressure and was adjusted according to the ventilatory graph, keeping transpulmonary pressures under 15 cmH 2 O. The P-low was adjusted according to the ventilatory graph, always maintaining transpulmonary pressures above 2 cmH 2 O. Pressure support was titrated to keep the spontaneous volume mobilized on the P-high close to 20% of its release volume, using the esophageal pressure graph to verify that it did not rise above 20 cmH 2 O of transpulmonary pressure. On the seventh day of mechanical ventilation, the patient was in the appropriate condition to initiate supported weaning (CPAP with added support pressure), using 11 cmH 2 O mean airway pressure (Table 4 , day 6). Under these conditions, a low-support spontaneous ventilation test was conducted, showing a rapid shallow breathing index (RSBI) of 34 and 57, a negative inspiratory force (NIF) of -27 cmH 2 O, and airway occlusion pressure in the first 100 milliseconds (P0.1) of -2 cmH 2 O, alongside the application of a negative cuff leak test. Considering these indicators, the patient was extubated with no complications, and weaning was consolidated with the support of a high-flow nasal cannula. Once weaning was consolidated, the patient was taken to the intermediary care unit. Although there is a general agreement on the reduction of tidal volume, plateau pressure, and driving pressure as key objectives of pulmonary care [2] , the most adequate way to determine positive end-expiratory pressure is still debated, as it has been for decades [11] . There have been cases where healthy animals have suffered ventilator-induced lung injuries (VILI) when ventilation produces pulmonary overdistention [12] . Although it is rare to reach such scores in clinical practice, note that in ARDS a substantial region of the lung is heterogeneous, inducing stress and involving the doubling of locally applied pressure as a possible side effect [1] . Although this is noteworthy and requires consideration when titrating mechanical ventilation, beneficial effects have been reported in several clinical studies when sufficient PEEP was used to drive transpulmonary pressure at the end of the expiration from a negative (indicating the closure or collapse of expiration) to a positive transition (indicating sustained permeability in this zone) [13] . In the present case, PEEP titration aimed to achieve these objectives (Table 3 , day 2, fifth round). In other cases, the use of an esophageal balloon has been criticized since it does not directly measure pleural pressure in distant pulmonary regions. Yet results from a recent study indicate that esophageal pressure is reliably close to absolute pleural pressure throughout its isogravitational plane [14] . In addition to the above, the restrictive component of the thoracic cage is increased by the weight of abdominal and thoracic adipose tissue (BMI 29), exposing the need to investigate the contribution of thoracic elasticity to lung mechanics. On the third day of mechanical ventilation, the patient was transferred to APRV, due to the potential benefits shown in a randomized clinical trial [15] and based on empirical results at our center. This modality maintains spontaneous respiration, and esophageal pressure screening in SDRA patients can be relevant, since deficient or excessive spontaneous force levels can lead to lesions on the lungs and diaphragm [16] . Secondly, calculated transpulmonary pressure is a useful indicator for clinicians to spot excessive spontaneous force-induced damage [17] , which can worsen lesions [18] . Furthermore, when spontaneous effort toward the end of the inspiration takes place with considerable muscle relaxation, transpulmonary pressure can reveal transalveolar pressure (namely, the component for alveolar expansion) [7] . Figure 4 shows indicators for transpulmonary pressure below 20 cmH 2 O in APRV, which means that alveolar distention is even lower, despite maintaining a PEEP high of 20 cmH 2 O. A recent case report on the usefulness of esophageal manometry during APRV implementation concludes that if transpulmonary pressure during release is unknown, then programming is being done blindly without knowing the frequency of alveolar collapse, as the report shows a transpulmonary pressure drop to below 0 cmH 2 O during expiration [19] . In our study, the use of APRV did not show transpulmonary pressure drops below 0 cmH 2 O, maintaining the pulmonary recruitment targets with esophageal manometry (Fig. 4) . This also allowed the team to maintain stable oxygenation targets without considerable alterations, as had occurred prior to the use of esophageal manometry, and achieve even greater stability during APRV (Fig. 7) . APRV requires spontaneous respiratory cycles and, as such, is associated with lower sedation levels. In this study, APRV use required the suspension of continuous midazolam infusion, raising the RASS from −5 to −3, while maintaining the administration of dexmedetomidine and fentanyl (Fig. 5) . The reduction in sedation was related to improvements in the hemodynamic profile parameters, likely due to an adrenergic rise and the spontaneous cycles that lead to intrathoracic pressure variation. The latter could cause increased venous return and preload, which can manifest itself in indexed intrathoracic blood volume from 999 to 1335 ml/m 2 . This allowed for the suspension of continuous noradrenaline infusion while maintaining indexed systemic vascular resistance scores between 1070 and 1860 dyne seconds/m 2 /cm 5 (Fig. 6A) and cardiac index scores above 4.1 L/minute/ m 2 even after discontinuing dobutamine (Fig. 6B) . These results are in line with the benefits described in the available literature on APRV use [6] . Asynchrony can worsen pulmonary lesions, as is the case in a "double trigger" event, where two consecutive inspirations are taken after a single respiratory effort [20] , thus doubling supplied tidal volume (TV). Double trigger cases are more frequent in patients with a greater respiratory impulse [21] . The adverse impact of asynchrony in patients on a ventilator is becoming more widely recognized, and the literature suggests a link between the rise of asynchrony and mortality [22] . Conventional pressure and flow monitoring over time can hide much of the interaction between patients and respirators, but esophageal pressure data can help detect asynchrony more easily [7] . Hence, careful monitoring of patient/ventilator interaction can help determine mechanical ventilation programming and sedoanalgesia levels [7] . Figure 4 shows that all the patient's spontaneous efforts (negative deflection in the transpulmonary and esophageal pressure curve) are accompanied by supported ventilation or APRV mandatory cycles. There is a growing need for research on APRV configuration considering its increased use. Since APRV involves spontaneous cycles, it allows for reduced sedation levels, improving adrenergic activity and diminishing vasoactive drug requirements (Figs. 5, 6 ). This report shows the usefulness of mechanical ventilation programming for lung protection using transpulmonary pressure monitoring. The report also suggests the usefulness of invasive mechanical ventilation Pes monitoring, both in controlled modalities and those allowing spontaneous respiration, such as APRV. It is important to note that the patient's overall medical condition, hemodynamic compromise, and the consequent fluctuating sedation levels did not allow the team to maintain a single ventilating modality and a steady programming, which in turn would have allowed for a more complete temporal assessment and description of Pes monitoring. Additionally, there was no continuous quantification of esophageal catheterization indicators in modalities that allow spontaneous respiration, and they were merely monitored. Their quantification can be established by directly measuring the Pes and Ptp pressure/time curve. However, these data were not recorded, and as such, the study only exemplifies their usefulness in APRV. This report describes Pes monitoring in different modalities. Further studies are required to better understand its use in patients who require the titration of their mechanical ventilation programming, both in controlled modalities and those allowing spontaneous respiration. However, it is necessary to perform introduction, calibration, and corroboration techniques to adequately position the esophageal balloon, both through gentle external manual epigastric compression [1] , and occlusion or Baydur tests [10] . ABGs: Arterial blood gas test; AC/VC: Volume-controlled assisted modality; AC/ PC: Pressure-controlled assisted modality; APACHE II: Acute physiology and chronic health disease classification system II; APRV: Airway pressure release ventilation; ARDS: Acute respiratory distress syndrome; ARDSNet: Acute respiratory distress syndrome network; B.E.: Base excess; BPM: Breaths per minute; CPAP: Continuous positive airway pressure; FiO 2 : Fraction of inspired oxygen; ICU: Intensive care unit; MAP: Mean arterial pressure; NIF: Negative inspiratory force; P.01.: Airway occlusion pressure in the first 100 milliseconds; PEEP: Positive end-expiratory pressure; Pes: Esophageal pressure; PLend-insp: Transpulmonary pressure during end inspiration; PLend-exp: Transpulmonary pressure during end expiration; Ptp: Transpulmonary pressure; RASS: Richmond Agitation-Sedation Scale; RSBI: Rapid shallow breathing index; SpO 2 : Pulse oximetry saturation; SaO 2 : Arterial oxygen saturation; VILI: Ventilatorinduced lung injuries; VT: Tidal volume. PLUG Working Group (Acute Respiratory Failure Section of the European Society of Intensive Care Medicine). Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives Acute respiratory distress syndrome: the Berlin Definition Airway pressure release ventilation: a new concept in ventilatory support Airway pressure release ventilation: what do we know? Respir Care Airway pressure-release ventilation in pregnant patients with acute respiratory distress syndrome: a novel strategy Airway pressure release ventilation and highfrequency oscillatory ventilation: potential strategies to treat severe • fast, convenient online submission • thorough peer review by experienced researchers in your field • rapid publication on acceptance • support for research data, including large and complex data types • gold Open Access which fosters wider collaboration and increased citations maximum visibility for your research: over 100M website views per year • At BMC, research is always in progress. Learn more biomedcentral.com/submissions Ready to submit your research Ready to submit your research ? Choose BMC and benefit from: ? Choose BMC and benefit from: hypoxemia and prevent ventilator-induced lung injury Ten tips to facilitate understanding and clinical use of esophageal pressure manometry Lung stress and strain during mechanical ventilation: any safe threshold? Effect of a nasogastric tube on esophageal pressure measurement in normal adults A simple method for assessing the validity of the esophageal balloon technique Should we titrate positive end-expiratory pressure based on an end-expiratory transpulmonary pressure? Lung inhomogeneity in patients with acute respiratory distress syndrome Stress distribution in lungs: a model of pulmonary elasticity Recruitment and derecruitment during acute respiratory failure: a clinical study Early application of airway pressure release ventilation may reduce the duration of mechanical ventilation in acute respiratory distress syndrome Evolution of diaphragm thickness during mechanical ventilation. Impact of inspiratory effort Extremely high transpulmonary pressure in a spontaneously breathing patient with early severe ARDS on ECMO The comparison of spontaneous breathing and muscle paralysis in two different severities of experimental lung injury Esophageal pressure balloon and transpulmonary pressure monitoring in airway pressure release ventilation: a different approach. Can J Respir Therapy CJRT (Revue Canadienne de la Therapie Respiratoire RCTR) Excessive tidal volume from breath stacking during lung-protective ventilation for acute lung injury Patient-ventilator asynchrony during assisted mechanical ventilation Asynchronies during mechanical ventilation are associated with mortality Acute respiratory distress syndrome caused by pulmonary and extrapulmonary disease: different syndromes? Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We have no acknowledgements.Authors' contributions OA, SU, FC, and RT conceived of the study, participated in its design and coordination, and helped to draft the manuscript. All authors read and approved the final manuscript. The authors received no funding for this work. Not applicable. Ethical approval and consent to participate At our institution, institutional review board approval is not required for a single case report. Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal. This report bears no conflict of interests, since no financing or sponsors were involved and the report is based only on data collection from a clinical case. The authors declare that they have no competing interests.