key: cord-0019575-3hedlr74 authors: Wang, Yawei; Chen, Lei; Xuan, Tiantian; Wang, Jian; Wang, Xiuwen title: Label-free Electrochemical Impedance Spectroscopy Aptasensor for Ultrasensitive Detection of Lung Cancer Biomarker Carcinoembryonic Antigen date: 2021-07-19 journal: Front Chem DOI: 10.3389/fchem.2021.721008 sha: 7bb4af536ea4f3492d7e2f711c86818238f66cb2 doc_id: 19575 cord_uid: 3hedlr74 In this work, an integrated electrode system consisting of a graphene working electrode, a carbon counter electrode and an Ag/AgCl reference electrode was fabricated on an FR-4 glass fiber plate by a polyethylene self-adhesive mask stencil method combined with a manual screen printing technique. The integrated graphene electrode was used as the base electrode, and AuNPs were deposited on the working electrode surface by cyclic voltammetry. Then, the carcinoembryonic antigen aptamer was immobilized using the sulfhydryl self-assembly technique. The sensor uses [Fe(CN)(6)](3−/4−) as a redox probe for label free detection of carcinoembryonic antigen based on the impedance change caused by the difference in electron transfer rate before and after the binding of carcinoembryonic antigen aptamer and the target carcinoembryonic antigen. The results showed a good linear relationship when the CEA concentration is in the range of 0.2–15.0 ng/ml. The detection limit was calculated to be 0.085 ng/ml (S/N = 3). In the early 1990s, scientists used in vitro screening techniques to isolate RNA and DNA molecules that specifically bind proteins, and these screened single-stranded oligonucleotides were called aptamers (Macugen Diabetic Retinopathy Study Group, 2005; Ostroff et al., 2010) . Oligonucleotides are short single-stranded nucleic acid molecules that bind selectively and with high affinity to proteins or other target molecules. Aptamers have many characteristics that antibodies do not have and are often used as recognition elements for aptamer sensors (Pavlov et al., 2004; Zayats et al., 2006) . Aptamers are easy to synthesize and easy to modify compared to other specific recognition elements. In immunoassays, antibodies need to be obtained from animals and live cells. In contrast, nucleic acid aptamers are usually screened in vitro using the SELEX technique (Sampson, 2003; Darmostuk et al., 2015) . In general, modification of antibodies leads to their inactivation. In contrast, modification of the aptamer does not affect either the activity or the binding of the aptamer to the target molecule Farzadfard et al., 2020) . Unlike antibodies, which usually bind only to their corresponding antigens, aptamers can recognize different targets such as proteins Liu et al. (2020) , peptides He et al. (2021) , amino acids Idili et al. (2019) , antibiotics Lin et al. (2018) , small molecules Nakatsuka et al. (2018) , viruses Chen et al. (2020) , and even metal ions . The affinity of the aptamer for the target is far stronger than the binding force between the antibody and the antigen. In addition, aptamers are more stable than antibodies, which can be stored for longer periods of time at room temperature. Aptamers can regain their activity under appropriate conditions after denaturation (Belleperche and DeRosa, 2018) . This feature of aptamers allows the lifespan of aptamer sensors to be extended. Electrochemical aptasensor integrate the disciplines of biology, chemistry, physics, electronics and medicine Kir, 2020; Ozbek et al., 2021) . These disciplines support and permeate each other, which has led to the gradual development of electrochemical aptasensor Fu et al., 2019a; Zhang M. et al., 2020; Kizilgeci et al., 2020; Özkan, 2020; Karimi-Maleh et al., 2021b) . Electrochemical aptamer sensor has the following advantages: fast analysis, simple operation method, good selectivity and high sensitivity. It is an analytical detection device constructed by combining an aptamer as a molecular recognition substance with electrochemical sensing (Fu et al., , 2019b Xu et al., 2020; Zheng et al., 2020) . Therefore, electrochemical aptamer sensor has gradually become a research hotspot. Currently, cancer remains the most feared disease in the world. In the early twenty-first century, prostate, lung, breast and colon cancers topped the list of deaths in the United States and Canada. In most developing countries, cancer was identified as the second leading cause of death. This led to the use of tumor markers Li et al. (2020a) , Duan et al. (2021) , Li et al. (2021) , Wang et al. (2021) , which are chemical-based substances that reflect the presence of tumors. They are not found in normal adult tissues but only in embryonic tissues Karimi-Maleh et al. (2021c) , Karaman (2021) , Karaman et al. (2021) , or are present in tumor tissues at levels that greatly exceed those found in normal tissues Vajhadin et al., 2020) . Their presence or quantitative changes can reveal the nature of tumors, lend to the understanding of tumor histogenesis, cell differentiation and cell function, which can provide assistance in tumor diagnosis, classification and treatment guidance. Early diagnosis of cancer is crucial to successfully save patients' lives. Therefore, sensitive and specific methods are needed to detect them. Disease detection is achieved by measuring the levels of biomarkers in blood, urine, and other body fluids. Carcinoembryonic antigen (CEA), an acidic glycoprotein with a relative molecular mass of 180 kDa, is of great importance for the development and monitoring of lung cancer (Yang et al., 2018; Song et al., 2020) . Usually, the CEA content in biological samples is very low, and the threshold value of CEA in human serum is 5.0 ng/ml. When the CEA content in serum is greater than 5.0 ng/ml, it may be a precursor of lung cancer (Gu et al., 2018; Jozghorbani et al., 2021) . Therefore, the detection of CEA is particularly important. So far, fluorescence analysis Qiu et al. , electrochemiluminescence Yang et al. (2020) and other methods have been used for CEA detection. Among these methods, electrochemical methods have attracted the interest of scientists due to the advantages of low cost and easy portability. Graphene, a two-dimensional carbon material with high electron density, dielectric properties and catalytic effects, which make it widely used in biosensors (Mohanraj et al., 2020; Özcan et al., 2020) . Most electrochemical aptamer sensors require labeling of the aptamer, which is a complicated process for labeling during experiments and may affect the specific binding of the aptamer to the target (Yang et al., 2017; Alavi-Tabari et al., 2018; Butmee et al., 2020; Naderi Asrami et al., 2020; Karimi-Maleh et al., 2021a) . In recent years, label free aptamer sensors have attracted the interest of scientists because of their label-free, simple operation, fast detection speed and low cost (Rizwan et al., 2018) . The main detection techniques used for label free aptamer sensors are electrochemical impedance spectroscopy (EIS) and square wave voltammetry coulometry. EIS has been widely developed and applied in the field of analytical chemistry for its high sensitivity (Singh et al., 2021) . In this work, an integrated thick film graphene electrode system consisting of a graphene working electrode, a large area carbon counter electrode and an Ag/AgCl reference electrode was fabricated by a polyethylene self-adhesive mask template method combined with screen printing technique. The integrated graphene electrode was used as the base electrode, and Au nanoparticle was deposited on the surface of the graphene working electrode by cyclic voltammetry. The CEA aptamer was immobilized by the sulfhydryl self-assembly technique, and [Fe(CN) 6 ] 3−/4− was used as the probe. The EIS electrochemical aptamer sensor for label free detection of CEA was constructed based on the change of mass transfer resistance at the electrode before and after the binding of [Fe(CN) 6 ] 3−/4− to the CEA. All reagents were analytical grade and used without further purification. Carcinoembryonic antigen aptamer (CEAaptamer) was purchased from Bioengineering Co.,Ltd. The sequence of the thiol-labeled CEA aptamer is: 5′-SH-ATACCAGCTTATTCAATT-3'. The carcinoembryonic antigen (CEA) was purchased from Shanghai Leadwave Biotechnology Co. Take the appropriate amount of conductive graphene ink and add it to the Petri dish, scrape it well with a scraper to get a uniform sticky conductive paste. The polyethylene self-adhesive presenter board is pasted onto a cleanly treated FR-4 glass fiberboard substrate (the fiberboard was washed with ethanol and distilled water and dried at room temperature). An integrated three-electrode system containing a graphene working electrode, a carbon counter electrode and a carbon reference electrode was obtained by screen printing technique. Then 1 layer of silver paste was evenly coated at the reference electrode and the prepared integrated electrode was dried in an oven at 70°C. An appropriate amount of 0.1 M FeCl 3 solution was dropped on the silver surface, and the silver was oxidized to FeCl 3 . After 1 h, the FeCl 3 solution was removed by rinsing with distilled water and air-dried to obtain the Ag/AgCl reference electrode. Finally, all areas except the working electrode, counter electrode, reference electrode and wire connection points were insulated with insulating tape. The preparation process of the aptamer sensor and the principle of detecting CEA was shown in Figure 1 . Firstly, the graphene SPE need to be activated. The SPE electrode was placed in 0.1 M PBS for CV scan. The scanning potential interval is between −0.5 and 1.5 V until a stable electrochemical signal was obtained. The treated SPE was placed in l mM HAuCl 4 solution and electrodeposited by CV. CV scan was performed at a potential of −1.5-1 V to obtain Au nanoparticle modified SPE (Au/SPCE). The Au/SPE was washed with water and dried at room temperature, then 5 μL of l μM CEA-aptamer solution was pipetted onto the Au/SPE surface and incubated for 15 h. The working electrode was then washed with PBS buffer solution to remove the unbound aptamer to obtain CEA-A/Au/SPE. To prevent non-specific adsorption on the electrode surface, 5 μL of 20.0 nM MCH solution was coated to the electrode surface for 10 min to close the blank sites on the electrode surface. Then, the electrode surface was thoroughly washed with PBS buffer solution to remove the excess MCH solution. The aptamer sensor M/CEA-A/Au/SPE was obtained. The surface morphology of SPE and Au/SPE was characterized using scanning electron microscopy, and the results are shown in Figure 2 . Figure 2A shows the SPE surface is relatively flat with a flaky distribution, which is consistent with the surface morphology of graphene (Kong et al., 2014) . When AuNPs were electrodeposited on the graphene electrode surface, a large number of uniform particles appeared on the electrode surface ( Figure 2B) , indicating that AuNPs were successfully deposited on the SPE surface. Figure 3 shows the EIS of the SPE and Au/SPE with different CV cycles. It can be seen that the electron transfer resistance of [Fe(CN) 6 ] 3−/4− on the SPE surface is relatively large. After the electrodeposition of AuNPs on the SPE surface, the electron transfer resistance of Au/SPE surface gradually decreases when the number of deposited cycle increases from 2 to 5, which indicates that the diffusion of [Fe(CN) 6 ] 3−/4− in Au/SPE was accelerated. This is because AuNPs has high electron density and excellent dielectric properties, which promote electron transfer and increase the reversibility of redox substances on the electrode surface (Chan et al., 2016) . When the number of deposition circles continues to increase, the electron transfer impedance of [Fe(CN) 6 ] 3−/4− on the Au/SPE surface almost no longer changes, indicating that the amount of AuNPs deposited on the SPE surface almost reaches saturation. We then characterized the assembly process of the aptamer sensor using EIS, as shown in Figure 4 [Fe(CN) 6 ] 3−/4− has a high electron transfer resistance at the SPE surface. When AuNPs were electrodeposited on the SPE surface, the electron transfer resistance decreased. This is because the AuNPs has excellent electrochemical properties, which accelerates the electron transfer rate of [Fe(CN) 6 ] 3−/4− on the electrode surface. When CEA-A was immobilized on the electrode surface by the sulfhydryl selfassembly technique, the electron transfer of [Fe(CN) 6 ] 3−/4− at the electrode surface was hindered. This is due to the fact that the aptamer is a negatively charged phosphate backbone, and [Fe(CN) 6 ] 3−/4− mutually repel each other and hinder electron transfer (Yan et al., 2014) . The impedance value further increases after using the sealer MCH to close the blank sites on the Frontiers in Chemistry | www.frontiersin.org July 2021 | Volume 9 | Article 721008 electrode surface that are not occupied by the aptamer. When l ng/mL CEA was incubated on the electrode, the impedance value continued to increase because the binding of the target CEA to the aptamer increased the spatial site resistance on the electrode surface and slowed down the electron transfer rate (Huang et al., 2012) . Also, we have characterized the whole assembly process using CV ( Figure 5 ). It can be seen from Figure 5 that [Fe(CN) 6 ] 3−/4− has good reversibility on the SPE. When AuNPs were electrodeposited on the SPE surface, the reversibility of [Fe(CN) 6 ] 3−/4− on Au/SPE was further enhanced and the peak potential difference was significantly reduced. When the CEA-A with sulfhydryl groups self-assembled on the Au/SPE surface through Au-S bonds, the aptamer carrying a negatively charged phosphate backbone would repel the negatively charged [Fe(CN) 6 ] 3−/4− and affect the electron transfer on the electrode surface, making the peak current smaller. Closure of the blank sites on the electrode surface not occupied by the aptamer with MCH formed a dense film on the electrode surface, which made the peak current further smaller. When 1 ng/ml of CEA was Frontiers in Chemistry | www.frontiersin.org July 2021 | Volume 9 | Article 721008 added, the electron transfer of [Fe(CN) 6 ] 3−/4− was hindered, and the peak potential difference increased and the peak current decreased. After the addition of 10 ng/ml of CEA, the peak current continued to decrease. The concentration of CEA-A immobilized on the surface of the electrode is an important factor affecting the performance of the sensor, so the CEA-A concentration was optimized. The relationship between the aptamer concentration of carcinoembryonic antigen and the electron transfer resistance (R et ) is shown in Figure 6A . When the aptamer concentration increased from 0.1 to 1 μM, the Ret of [Fe(CN) 6 ] 3−/4− on the sensor surface also increased gradually. When the aptamer concentration continued to increase to 30 μM, the impedance value reached a plateau and almost stopped changing. This indicates that the amount of CEA-A immobilized on the sensor surface has reached saturation. Therefore, the concentration of carcinoembryonic antigen aptamer was chosen to be 1 μM in subsequent experiments. The immobilization time of the aptamer is an important factor that affects the performance of the aptamer sensor, therefore, the immobilization time of the aptamer was optimized. Figure 6B shows the relationship between the change of [Fe(CN) 6 ] 3−/4− in the sensor surface heart after different times of immobilization of the CEA aptamer on the electrode surface for 1 μM. As can be seen from the figure, the R et of the sensor gradually increases when the immobilization time of the CEA aptamer increases from 3 to 15 h. When the immobilization time increases from 15 to 21 h, the impedance value reaches a plateau and basically stops changing, indicating that the amount of aptamer immobilization has basically reached the saturation state. Therefore, the selected aptamer immobilization time was 15 h. The binding time between the aptamer sensor and the target CEA is also an important factor affecting the performance of the sensor, so the binding time between the sensor and CEA was investigated in this experiment. The aptamer sensor was incubated with 10 μL of 0.5 ng/ml CEA at 37°C for different times, and the experimental results were shown in Figure 6C . It can be seen that when the incubation time was varied between 10-60 min, a significant increase in the electron transfer resistance occurred with the increase of time. When the incubation time was between 60-70 min, there was a small decrease in R ct . When incubation time excess 70 min, R ct tended to be stable. This indicates that 70 min is a more reasonable time for specific binding of the aptamer to the target. Figure 7 . Figure 7A shows the EIS plots of the aptamer sensor combined with different concentrations of CEA. It can be seen from Figure 7A that the impedance value of the aptamer sensor in the blank solution is the smallest, and the impedance value increases gradually when different concentrations of the target CEA were added. This is because CEA binds to the aptamer immobilized on the aptamer sensor, resulting in an increasing electron transfer resistance of [Fe(CN) 6 ] 3−/4− . Figure 7B shows the variation of electron transfer resistance with CEA concentration. It can be seen from the figure that there is a good linear relationship between the electrochemical aptamer sensor and CEA when the CEA concentration is in the range of 0.2-15.0 ng/ml. The detection limit is 0.085 ng/ml (S/N 3). The selectivity study was carried out to compare the sensor's selectivity performance of 10 ng/ml of CEA against DHEA, AFP, Leptin, AA, BSA and UA. The results demonstrated high selectivity with standard deviation less than 10%. Graphene ink was used to prepare SPE. a simple and fast unlabeled impedance-based electrochemical aptamer sensor for CEA detection was constructed by electrochemical deposition of AuNPs on the surface of SPE working electrode using cyclic voltammetry. CEA-A was immobilized on the electrode surface by the sulfhydryl self-assembly technique. After optimizations, the sensor can linear detection of CEA in the range of 0.2-15.0 ng/ml. The detection limit is 0.085 ng/ml (S/N 3). The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author. Author Contributions YW and XW conceived of the study. JW and SW supervised the development program, YW, LC and TX conducted the materials characterization. YW and TX received and curated samples and analytical records. YW and LC wrote the manuscript. All authors read and approved of the manuscript. Extraction, Purification of Prostate-specific Antigen (PSA), and Establishment of Radioimmunoassay System as a Diagnostic Tool for Prostate Disorders Simultaneous Determination of Doxorubicin and Dasatinib as Two Breast Anticancer Drugs Uses an Amplified Sensor With Ionic Liquid and ZnO Nanoparticle pH-Control in Aptamer-Based Diagnostics, Therapeutics, and Analytical Applications An Ultrasensitive Immunosensor Based on Manganese Dioxide-Graphene Nanoplatelets and Core Shell Fe3O4@Au Nanoparticles for Label-Free Detection of Carcinoembryonic Antigen Fabrication of Graphene/gold-Modified Screen-Printed Electrode for Detection of Carcinoembryonic Antigen A DNA Aptamer Based Method for Detection of SARS-CoV-2 Nucleocapsid Protein Current Approaches in SELEX: An Update to Aptamer Selection Technology A Methylene Blue Assisted Electrochemical Sensor for Determination of Drug Resistance of Escherichia coli Modification of Reduced graphene/Au-Aptamer to Develop an Electrochemical Based Aptasensor for Measurement of Glycated Albumin Graphene Ink Film Based Electrochemical Detector for Paracetamol Analysis Lycoris Species Identification and Infrageneric Relationship Investigation Via Graphene Enhanced Electrochemical Fingerprinting of Pollen High Selective Detection of Mercury (II) Ions by Thioether Side Groups on Metal-Organic Frameworks Electrochemical Detection of Carcinoembryonic Antigen An Electrochemical Impedimetric Sensing Platform Based on a Peptide Aptamer Identified by High-Throughput Molecular Docking for Sensitive L-Arginine Detection Electrochemical Immunoassay of Carcinoembryonic Antigen Based on TiO2-Graphene/ Thionine/Gold Nanoparticles Composite An Electrochemical Aptamer-Based Sensor for the Rapid and Convenient Measurement of L-Tryptophan Frontiers in Chemistry | www.frontiersin.org Determination of Carcinoembryonic Antigen as a Tumor Marker Using a Novel Graphene-Based Label-free Electrochemical Immunosensor Electrochemical Immunosensor Development Based on Core-Shell High-Crystalline Graphitic Carbon Nitride@ Carbon Dots and Cd 0.5 Zn 0.5 S/d-Ti 3 C 2 T X MXene Composite for Heart-type Fatty Acid-Binding Protein Detection Orange Peel Derived-Nitrogen and Sulfur Co-doped Carbon Dots: a Nano-booster for Enhancing ORR Electrocatalytic Performance of 3D Tuning of Metal Oxides Photocatalytic Performance Using Ag Nanoparticles Integration Guanine-based DNA Biosensor Amplified with Pt/SWCNTs Nanocomposite as Analytical Tool for Nanomolar Determination of Daunorubicin as an Anticancer Drug: a Docking/experimental Investigation A Critical Review on the Use of Potentiometric Based Biosensors for Biomarkers Detection A Novel Detection Method for Organophosphorus Insecticide Fenamiphos: Molecularly Imprinted Electrochemical Sensor Based on Core-Shell Co3O4@MOF-74 Nanocomposite Yield and Quality Traits of Some Silage maize Cultivars Growth and Physiological Traits of Five Bread Wheat (Triticum aestivumL.) Genotypes Are Influenced by Different Levels of Salinity and Drought Stress A Paper Disk Equipped with graphene/polyaniline/Au Nanoparticles/glucose Oxidase Biocomposite Modified Screen-Printed Electrode: Toward Whole Blood Glucose Determination A sandwich-type Electrochemical Immunosensor for Ultrasensitive Detection of Multiple Tumor Markers Using an Electrical Signal Difference Strategy Electrochemical Sensor for a Photoassisted Heterogeneous Fenton Self-Oxidation Signal Amplification Strategy A Novel Graphene-Based Nanomaterial Modified Electrochemical Sensor for the Detection of Cardiac Troponin I Point-of-care Testing for Streptomycin Based on Aptamer Recognizing and Digital Image Colorimetry by Smartphone In Vitro selection of a DNA Aptamer Targeting Degraded Protein Fragments for Biosensing A Phase II Randomized Double-Masked Trial of Pegaptanib, an Anti-vascular Endothelial Growth Factor Aptamer, for Diabetic Macular Edema Facile Synthesis of Paper Based Graphene Electrodes for point of Care Devices: a Double Stranded DNA (dsDNA) Biosensor Glucose Oxidase/nano-ZnO/thin Film deposit FTO as an Innovative Clinical Transducer: a Sensitive Glucose Biosensor Aptamer Recognition of Multiplexed Small-Molecule-Functionalized Substrates Unlocking Biomarker Discovery: Large Scale Application of Aptamer Proteomic Technology for Early Detection of Lung Cancer Investigation on Energy Use Efficiency and Greenhouse Gas Emissions (GHG) of Onion Cultivation A Novel Molecularly Imprinting Biosensor Including Graphene Quantum Dots/multi-Walled Carbon Nanotubes Composite for Interleukin-6 Detection and Electrochemical Biosensor Validation Effect of Gold Nanoparticle Functionalized Multi-Walled Carbon Nanotubes on the Properties of Na-Bentonite Water Based Drilling Fluid Aptamerfunctionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin Bioresponsive Release System for Visual Fluorescence Detection of Carcinoembryonic Antigen from Mesoporous Silica Nanocontainers Mediated Optical Color on Quantum Dot-Enzyme-Impregnated Paper AuNPs/CNOs/ SWCNTs/chitosan-nanocomposite Modified Electrochemical Sensor for the Label-free Detection of Carcinoembryonic Antigen Aptamers and SELEX: the A Robust Electrochemical Immunosensor Based on Core-Shell Nanostructured Silica-Coated Silver for Cancer (Carcinoembryonic-Antigen-CEA) First Use of Inorganic Copper Silicate-Transduced Enzyme-free Electrochemical Immunosensor for Carcinoembryonic Antigen Detection Electrochemical Cytosensors for Detection of Breast Cancer Cells Highly Sensitive Electrochemical Immunosensor for the Simultaneous Detection of Multiple Tumor Markers for Signal Amplification A Smartphone-Based Enzyme-Linked Immunochromatographic Sensor for Rapid Quantitative Detection of Carcinoembryonic Antigen Infrageneric Phylogenetics Investigation of Chimonanthus Based on Electroactive Compound Profiles An Origami Electrochemiluminescence Immunosensor Based on Gold/graphene for Specific, Sensitive point-of-care Testing of Carcinoembryonic Antigen Frontiers in Chemistry | www.frontiersin.org A Novel Label-free Electrochemical Immunosensor Based on Functionalized Nitrogen-Doped Graphene Quantum Dots for Carcinoembryonic Antigen Detection Ultrasensitive Electrochemical Immunosensor of Carcinoembryonic Antigen Based on Gold-Label Silver-Stain Signal Amplification An AIEgen-Based 2D Ultrathin Metal-Organic Layer as an Electrochemiluminescence Platform for Ultrasensitive Biosensing of Carcinoembryonic Antigen Label-free and Reagentless Aptamer-Based Sensors for Small Molecules Photomodulating Gene Expression by Using Caged siRNAs with Single-Aptamer Modification Recording the Electrochemical Profile of Pueraria Leaves for Polyphyly Analysis Plug and Play" Logic Gate Construction Based on Chemically Triggered Fluorescence Switching of Gold Nanoparticles Conjugated with Cy3-Tagged Aptamer Preparation Gold Nanoparticles Using Herb Leaf Extract for Electro-Oxidation Determination of Ascorbic Acid Phylogenetic Investigation of Yellow Camellias Based on Electrochemical Voltammetric Fingerprints The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Copyright © 2021 Wang, Chen, Xuan, Wang and Wang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.