key: cord-0018875-933u3ij9 authors: Diehl, Jean-Luc; Talmor, Daniel title: When could airway plateau pressure above 30 cmH(2)O be acceptable in ARDS patients? date: 2021-07-08 journal: Intensive Care Med DOI: 10.1007/s00134-021-06472-5 sha: cdb32bba814a2f1f7784781295413a501bc0f0ce doc_id: 18875 cord_uid: 933u3ij9 nan Limitation of plateau pressure (P plateau ) is critical for protection from ventilator-induced lung injury in patients with acute respiratory distress syndrome (ARDS) [1] . Limiting to a 30 cmH 2 O threshold is a widely accepted recommendation for lung protection, in addition to the use of low tidal volume (V T ) and positive end-expiratory positive pressure (PEEP) [2] . Moreover, P plateau is in of itself a powerful determinant of mortality in the general ARDS patient population [1] , as well as being a component of other parameters associated with the risk of ventilator-induced lung injury and/or the clinical prognosis of ARDS patients, such as driving pressure or mechanical power [3, 4] . In this short piece, we will discuss two conditions in which allowing a P plateau above 30 cmH 2 O may be advisable in ARDS patients. The approach to these conditions is based on the concepts that: i. The respiratory changes in esophageal pressure (P es ) reflect the respiratory changes in pleural pressure, permitting to estimate the end-inspiratory transpulmonary pressure (P L ) in the non-dependent lung regions, after correcting P plateau with the ratio of chest wall elastance (E CW ) on respiratory system elastance (E RS ). ii. The measured P es values are a clinically relevant surrogate for pleural pressure values in the dependent lung regions. We will discuss how to safely apply and monitor an elevated P plateau in light of these concepts. The first condition corresponds to ARDS patients with very high chest wall elastance (E CW ). Panels a and b of Fig. 1 illustrate such a situation. Esophageal (red line) and airway (blue line) pressures are displayed. PEEP was set to 8 cmH 2 O, with resulting end-expiratory and endinspiratory trans-pulmonary pressures (P L ) of 3 cmH 2 O and 13 cmH 2 O, respectively. These pressures, reflecting the stress applied to the lung structure, remained in a safe range [5] . The tidal difference in P L (ΔP L ), the driving pressure of the lung, was near to the limit proposed by international experts [6] . In addition, it was shown that end-inspiratory P L in the non-dependent lung (P L,ER) , at high risk of alveolar hyperinflation, can be estimated by the following calculation: P L,ER = P plateau -[P plateau × (E CW /E RS )], also expressed as: P L,ER = P plateau × (E L /E RS ), best illustrating that variations in E L /E RS strongly influence P L,ER for a given plateau pressure. P L,ER is the end-inspiratory trans-pulmonary pressure calculated from elastance ratio of chest wall to respiratory system (E RS ) [5, 7, 8] . The calculation indicated a P L,ER value largely below the proposed threshold of 22-25 cmH 2 O, therefore, suggesting mechanical ventilation settings remaining in a safe range [5, 7] . Finally, the clinical validity of such an approach was previously demonstrated in a series of patients suffering from influenza A (H1N1)associated ARDS referred for extracorporeal membrane oxygenation (ECMO) [8] . Among 14 patients, PEEP setting was optimized according to the above parameters, permitting to improve oxygenation parameters without ECMO support in half of the patients. The second condition corresponds to ARDS patients with a very high pleural pressure, as estimated by P es monitoring. This situation can be present in obese patients, patients with fluid overload or abdominal distension. These patients have normal or near-normal E CW values [9] . Panels c and d of Fig. 1 illustrate such a situation. While end-inspiratory P es (Panel d) was only moderately higher than in the first situation (panel b), there was a major difference between the two conditions in endexpiratory P es , which was found to be near to 34 cmH 2 O (panels C and D). PEEP was set to 35 cmH 2 O to achieve a positive end-expiratory P L , avoiding end-expiratory lung collapse [5] . In spite of the elevated airway pressures, end-expiratory and end-inspiratory P L were near to 2 cmH 2 O and 9 cmH 2 O, respectively. These values, along with the calculated ΔP L , are all in a safe range. The clinical validity of this approach has been shown in an observational series of 50 morbidly obese ARDS patients [10] . Titration of PEEP according to end-expiratory PL was associated to a decrease in mortality rate. Of note, the strategy also included lung recruitment maneuvers and a careful hemodynamic evaluation of the consequences of the proposed mechanical ventilation settings. Not all evidence supports this approach, with a lower level of evidence as compared to other therapeutic approaches, such as particularly prone positioning. However, the approaches can be complementary, and partitioning chest wall and lung mechanics in prone position is clinically relevant. The EPVent-2 study evaluated in 200 moderate to severe ARDS patients the benefit of a PEEP titration guided by P es , as compared to an empirical high PEEP-FiO 2 strategy [11] . There was no difference in a panels c and d) . The first condition is illustrated based on tracings from a patient suffering from severe pleural sequelae following thoracic surgery. Of note, the first condition is very infrequent in the clinical practice, while the second condition is more frequently observed, especially in morbidly obese patients. The two patients benefited from esophageal manometry using a Nutrivent probe (Sidam, Italy) for trans-pulmonary pressure measurements because of severe oxygenation parameters despite optimization of mechanical ventilator settings based on airway pressures measurements and prone positioning. Tracings were obtained in the 30° semi-recumbent position. An endexpiratory pause, allowing measurements of corresponding pressures, is displayed in panels a and c. An end-inspiratory pause, allowing measurements of corresponding pressures, is displayed in panels b and d. Tidal volume was set at 6 mL/Kg IBW for the two patients, with values of 230 and 450 mL, respectively. A time lag was observed between the esophageal pressure and airway pressure. This was probably in relation with Nutrivent probe characteristics and with the 164 cm length connection line (connection line for GE ventilators, Sidam, Italy) with either the CareScape R860 ventilator (panels a and b) or an external acquisition system (panels c and d). Clinicians should be aware of such possibilities, since calculations without time realignment could induce errors in calculations outside prolonged inspiratory and expiratory pauses composite endpoint incorporating death and mechanical ventilation free days. Importantly though, the control arm of this study received very high levels of PEEP, equal to those in the P ES -guided group, a finding which may have blurred individual differences. These results do not support a systematic use of P es -guided titration in all ARDS patients, but rather, in our view, a selection of ARDS patients in whom one can suspect increased pleural pressure. Ongoing secondary analysis of this trial will clarify these issues. While waiting further studies on this topic, such a selection could be based on the medical history of the patients and on baseline characteristics, such as BMI values. Of note, even if a rather good correlation (R 2 = 0.45) was found between end-expiratory P es and BMI in a series of 51 ARDS patients [9] , it is likely that other factors, such as the distribution of obesity (central, abdominal, etc.) and the abdominal elastance, are important to consider. In this way, adding end-expiratory lung volumes measurements to trans-pulmonary pressure measurements or calculations could help to select PEEP levels associated to the best compromise between recruitment and overdistension. It is important to mention the need to avoid any deleterious hemodynamic consequences of the proposed approach. Indeed, as described in experimental and clinical studies, increases in positive pleural pressure influence central vascular pressures and venous return can affect systemic hemodynamics and can induce renal, liver or gut dysfunction [12] [13] [14] . Accordingly, careful monitoring of the hemodynamics and organ functions is mandatory in the above-mentioned conditions. Estimation of abdominal pressures and elastance, as permitted by bladder or gastric pressures monitoring devices, could be of value. Another important pitfall to mention is the influence of body position on the measured respiratory parameters: we previously described three ARDS patients with unusually large increases in P plateau while moving from supine to 45° semi-recumbent positions [15] . While this was in relation with a rise in pleural pressure in a morbidly obese patient, possibly in link with abdominal compression, this was in relation to an increase in lung elastance in the two other patients, with rare ARDS etiologies, implying to decrease the applied PEEP level [15] . Finally, technical pitfalls in relation to P es monitoring should also be well known by the critical care physicians [6] . A quantile analysis of plateau and driving pressures: effects on mortality in patients with acute respiratory distress syndrome receiving lung-protective ventilation Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome Driving pressure and survival in the acute respiratory distress syndrome Ventilator-related causes of lung injury: the mechanical power Guiding ventilation with transpulmonary pressure Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives Esophageal manometry and regional transpulmonary pressure in lung injury ECMO criteria for influenza A (H1N1)-associated ARDS: role of transpulmonary pressure Prevalence of complete airway closure according to body mass index in acute respiratory distress syndrome A lung rescue team improves survival in obesity with acute respiratory distress syndrome Effect of titrating positive end-expiratory pressure (PEEP) with an esophageal pressureguided strategy vs an empirical high PEEP-FiO 2 strategy on death and days free from mechanical ventilation among patients with acute respiratory distress syndrome: a randomized clinical trial Effect of PEEP ventilation on renal function, plasma renin, aldosterone, neurophysins and urinary ADH, and prostaglandins The effects of mechanical ventilation on the gut and abdomen Paradoxical effects of positioning in patients with ARDS and preexisting pulmonary vasculitis or similar disorders The authors thank Luciano Gattinoni for helpful and stimulating discussions, which made it possible, at least in part, to improve the presentation and the limits of the proposed therapeutic approaches. The authors also thank Marine Rolland and Marion Placais for working on medical reports and advanced respiratory monitoring files of illustrative patients. No specific funding in relation with the manuscript. Not applicable. The authors have no conflicts related to the submitted research manuscript. Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.