key: cord-0017687-gbtojvxr authors: Wang, Anyang; Boroujeni, Samaneh Moghadasi; Schneider, Philip J.; Christie, Liam B.; Mancuso, Kyle A.; Andreadis, Stelios T.; Oh, Kwang W. title: An Integrated Centrifugal Degassed PDMS-Based Microfluidic Device for Serial Dilution date: 2021-04-23 journal: Micromachines (Basel) DOI: 10.3390/mi12050482 sha: 8f999b0672cfab8f29c50c2e3ed0162ac1db3bfb doc_id: 17687 cord_uid: gbtojvxr We propose an integrated serial dilution generator utilizing centrifugal force with a degassed polydimethylsiloxane (PDMS) microfluidic device. Using gas-soluble PDMS as a centrifugal microfluidic device material, the sample can be dragged in any arbitrary direction using vacuum-driven force, as opposed to in a single direction, without adding further actuation components. The vacuum-driven force allows the device to avoid the formation of air bubbles and exhibit high tolerance in the surface condition. The device was then used for sample metering and sample transferring. In addition, centrifugal force was used for sample loading and sample mixing. In this study, a series of ten-fold serial dilutions ranging from [Formula: see text] to [Formula: see text] with about 8 μL in each chamber was achieved, while the serial dilution ratio and chamber volume could easily be altered by changing the geometrical designs of the device. As a proof of concept of our hybrid approach with the centrifugal and vacuum-driven forces, ten-fold serial dilutions of a cDNA (complementary DNA) sample were prepared using the device. Then, the diluted samples were collected by fine needles and subject to a quantitative polymerase chain reaction (qPCR), and the results were found to be in good agreement with those for samples prepared by manual pipetting. Strategies for the generation of bio-molecular and chemical concentration gradients have been widely studied in the context of applications involving sample preparation and analysis. Examples include cell migration for chemotaxis [1] , quantitative polymerase chain reaction (qPCR) [2, 3] , enzyme-linked immunosorbent assay (ELISA) [4] , and highthroughput screening (HTS) [5] . Various approaches are used to generate serial dilutions of liquid samples in biology and chemical research. Microplates are widely used in the laboratory research setting as a standard tool in sample preparation and analytical quantification. Each "well" or small fluid reservoir typically has a capacity in the range of nanoliters to microliters. Furthermore, each plate can have up to thousands of sample wells. For instance, one of the most common microplate formats is the 96-well microplate with a capacity of 400 µL/well. A typical procedure involves manual pipetting of samples into each microwell and mixing with dilution buffers. This is a time-consuming process that requires some form of a skilled operator. In addition, reagent. The limitation of the device is that the device performance was surface-sensitive, and the channel was required to be hydrophilic to utilize the siphon valves effectively. Vacuum-driven pumping has been attracting increased attention as an alternative to passive pumping methods [13, 29, 30] . Gas-solubility-based vacuum-driven pumping utilizes the gas solubility property of materials ( Figure 1 ). The device is made from materials with good gas solubility is degassed before use. Advantages of the vacuumdriven approach are absence of bubble formation [11, [31] [32] [33] , high tolerance to surface conditions [13, 29] , and robust passive pumping [11, 13] . Vacuum-driven pumping can easily be integrated with other types of pumping without the need for additional peripherals. Vacuum-driven pumping has been attracting increased attention as an alternative to passive pumping methods [13, 29, 30] . Gas-solubility-based vacuum-driven pumping utilizes the gas solubility property of materials ( Figure 1 ). The device is made from materials with good gas solubility is degassed before use. Advantages of the vacuum-driven approach are absence of bubble formation [11, [31] [32] [33] , high tolerance to surface conditions [13, 29] , and robust passive pumping [11, 13] . Vacuum-driven pumping can easily be integrated with other types of pumping without the need for additional peripherals. This paper proposes an integrated centrifugal, degassed, Polydimethylsiloxane (PDMS)-based microfluidic device for serial dilution applications. The device utilizes both centrifugal force and vacuum-driven force to drive a liquid sample with the assistance of geometrical constraints, such as capillary valves [14, 34, 35] and phase-guide structures [36] . The use of a combination of two actuation methods complements the drawbacks of each. Limitations of centrifugal pumping, such as one-directional force and air bubble generation, can be overcome by introducing vacuum-driven pumping in combination. Limitations of vacuum-driven pumping, such as restricted flow rates and difficulty in achieving sample mixing because of the inherent pressure difference, can be compensated by using this method in combination with centrifugal microfluidics. Figure 1 . General device configurations and preparation for the degassed PDMS-based vacuumdriven pumping. When the whole microfluidic device is made of materials (e.g., PDMS), it can function as a self-powered vacuum source. The device is pre-degassed before usage to let dissolved air is driven out. Once the degassed device is exposed to air again, the materials start to reabsorb air from all surroundings, including embedded microfluidic channels, resulting in a vacuum that will draw sample liquids along the microfluidic channels. The image shows a simple microfluidic device to demonstrate the vacuum-driven pumping using the degassed PDMS. Centrifugal force and vacuum-driven force are the two main forces being leveraged in this device, as shown in Figure 2 . This is aside from the effects of a Coriolis force and the moment of inertia. The dominant force is switched between the centrifugal force and the vacuum-driven force during device operation. The conditions to trigger centrifugal flows and vacuum-driven flows are compared and illustrated in Figure 2b ,c. The centrifugal flows require a spin with a rotational speed N and a vent to deliver the liquid sample into the chamber. The vacuum-driven flows require the device made from materials with good gas solubility (e.g., PDMS) to be degassed before operation. Additionally, Figure 1 . General device configurations and preparation for the degassed PDMS-based vacuumdriven pumping. When the whole microfluidic device is made of materials (e.g., PDMS), it can function as a self-powered vacuum source. The device is pre-degassed before usage to let dissolved air is driven out. Once the degassed device is exposed to air again, the materials start to reabsorb air from all surroundings, including embedded microfluidic channels, resulting in a vacuum that will draw sample liquids along the microfluidic channels. The image shows a simple microfluidic device to demonstrate the vacuum-driven pumping using the degassed PDMS. This paper proposes an integrated centrifugal, degassed, Polydimethylsiloxane (PDMS)based microfluidic device for serial dilution applications. The device utilizes both centrifugal force and vacuum-driven force to drive a liquid sample with the assistance of geometrical constraints, such as capillary valves [14, 34, 35] and phase-guide structures [36] . The use of a combination of two actuation methods complements the drawbacks of each. Limitations of centrifugal pumping, such as one-directional force and air bubble generation, can be overcome by introducing vacuum-driven pumping in combination. Limitations of vacuum-driven pumping, such as restricted flow rates and difficulty in achieving sample mixing because of the inherent pressure difference, can be compensated by using this method in combination with centrifugal microfluidics. Centrifugal force and vacuum-driven force are the two main forces being leveraged in this device, as shown in Figure 2 . This is aside from the effects of a Coriolis force and the moment of inertia. The dominant force is switched between the centrifugal force and the vacuum-driven force during device operation. The conditions to trigger centrifugal flows and vacuum-driven flows are compared and illustrated in Figure 2b ,c. The centrifugal flows require a spin with a rotational speed N RPM and a vent to deliver the liquid sample into the chamber. The vacuum-driven flows require the device made from materials with good gas solubility (e.g., PDMS) to be degassed before operation. Additionally, the chamber should be dead-end to allow liquid sample delivery. For example, in Figure 2b , the sample can be loaded from the top chamber to the bottom chamber, where the vent is open to the air, by applying angular velocity (centrifugal force). Once the sample was transferred to the bottom chamber, the sample from the chamber to the adjacent chamber, there is no opening and considered as a dead-end chamber. Considering the vacuum-driven pumping concept in Figure 2c , the sample would be transferred by vacuum-driven pumping. In short, to drive the sample with a centrifugal force, the target chamber should be open to the air in addition to the angular velocity, while to drive the sample with vacuum-driven force, the target chamber should be close. If wisely designed the device and let the liquid sample go through the open chamber and the close chamber one after another, we can make the situation to drive the sample using the centrifugal force and the vacuum-driven force one after another. the chamber should be dead-end to allow liquid sample delivery. For example, in Figure 2b , the sample can be loaded from the top chamber to the bottom chamber, where the vent is open to the air, by applying angular velocity (centrifugal force) . Once the sample was transferred to the bottom chamber, the sample from the chamber to the adjacent chamber, there is no opening and considered as a dead-end chamber. Considering the vacuumdriven pumping concept in Figure 2c , the sample would be transferred by vacuum-driven pumping. In short, to drive the sample with a centrifugal force, the target chamber should be open to the air in addition to the angular velocity, while to drive the sample with vacuum-driven force, the target chamber should be close. If wisely designed the device and let the liquid sample go through the open chamber and the close chamber one after another, we can make the situation to drive the sample using the centrifugal force and the vacuum-driven force one after another. Figure 3 shows the images and schematics of the proposed device for a ten-fold serial dilution. The device has two inlets: inlet A for sample loading and inlet B for buffer loading. There are five sets of metering chambers and dilution chambers corresponding to serial dilutions with concentrations of 10 , 10 , 10 , 10 , and 10 , aside from waste chambers for holding the excess volume of sample and buffer after the metering process. The device has three vents: two vents are in waste chambers, and one vent is in #1D (the ports of other vents in #2D, #3D, and #4D are not punched in this study). First, metering chambers are designed to allocate 8.96 μL in #1 M; 8.07 μL each in #2M, #3M, and #4M; and 7.26 μL in #5M. Dilution chambers are constructed with the aim of having a series of Figure 2 . (a) The 3D and (b) 2D schematics of the operation principle using driving pressure by centrifugal force, ∆P d , or vacuum-driven pressure, P v . The centrifugal pressure allows the sample to be driven in a one-way direction, while the vacuum-driven force can be used for various directions to drag the sample without any rotation. To switch the dominant forces between centrifugal force and vacuum-driven force to drive samples, the fluidic passage should be wisely designed. For instance, if we let the liquid sample go through the open chamber and the closed chamber one after another, we can make the situation to let the sample driven by centrifugal force (with a rotation) and the vacuum-driven force one after another. (c) The comparison between the centrifugal flows and the vacuum-driven flows in each dead-end and open-end channel. The centrifugal pressure requires an open-end channel to drive a sample, while the vacuum-driven pressure requires a dead-end channel to drive a sample. In the proposed device, a dominant force is switched between the centrifugal force and the vacuum-driven force. N RPM is a rotational speed. Figure 3 shows the images and schematics of the proposed device for a ten-fold serial dilution. The device has two inlets: inlet A for sample loading and inlet B for buffer loading. There are five sets of metering chambers and dilution chambers corresponding to serial dilutions with concentrations of 10 0 , 10 −1 , 10 −2 , 10 −3 , and 10 −4 , aside from waste chambers for holding the excess volume of sample and buffer after the metering process. The device has three vents: two vents are in waste chambers, and one vent is in #1D (the ports of other vents in #2D, #3D, and #4D are not punched in this study). First, metering chambers are designed to allocate 8.96 µL in #1 M; 8.07 µL each in #2M, #3M, and #4M; and 7.26 µL in #5M. Dilution chambers are constructed with the aim of having a series of ten-fold serial dilutions ranging from 10 0 to 10 −4 . The device is composed of three layers: a PDMS top layer, a PDMS bottom layer, and a glass slide substrate. The bottom layer possesses a symmetric design concerning the top layer to possess sufficient chamber height for efficient mixing and relatively large sample volumes (~7 to~10 µL). A single layer of PDMS microfluidic channel/chamber with a glass slide substrate may work as well; however, it is not easy to keep uniform, especially concerning the depth of chambers of a few hundred micrometers scale. The fabrication process will be discussed later. However, making thick chambers in a single layer of PDMS using the soft lithography process is not easy and can be subject to the edge bead effect [37] , resulting in a non-uniform depth. Micromachines 2021, 12, x FOR PEER REVIEW 5 of 15 ten-fold serial dilutions ranging from 10 to 10 . The device is composed of three layers: a PDMS top layer, a PDMS bottom layer, and a glass slide substrate. The bottom layer possesses a symmetric design concerning the top layer to possess sufficient chamber height for efficient mixing and relatively large sample volumes (~7 to ~10 μL). A single layer of PDMS microfluidic channel/chamber with a glass slide substrate may work as well; however, it is not easy to keep uniform, especially concerning the depth of chambers of a few hundred micrometers scale. The fabrication process will be discussed later. However, making thick chambers in a single layer of PDMS using the soft lithography process is not easy and can be subject to the edge bead effect [37] , resulting in a non-uniform depth. There are three vents in total; two vents in the waste chambers are used for sample metering, and one vent in #1D is used for sample transfer. To generate a series of ten-fold serial dilutions, the sample is subject to the metering process, transfer from the metering chambers to the dilution chambers, mixing in each dilution chamber, and transfer of one-tenth of the sample volume from one dilution chamber to the next dilution chamber. Figure 4 shows the core working principle of our proposed device using both the centrifugal and vacuum-driven forces. Before usage, all PDMS devices were degassed in a vacuum chamber under ~0.1 ATM overnight. (i) First, the sample and buffer were loaded into the device using a pipette. (ii) The liquid sample and buffer were metered by vacuum-driven flows: 8.96 μL (#1) for the sample containing blue dye; 8.07 μL (#2, #3, and #4) and 7.26 μL (#5) for the buffer containing red dye. Here, in order to achieve the same sample volume (~ 8 μL) of the dilution series, in the end, the first chamber has ~10% more volume, and the last chamber has ~ 10% less volume than the targeting sample volume in the metering process, considering the serial dilution process. Abrupt geometrical height/width differences in channels and chambers using phaseguide structures [36] enabled precise metering and aliquoting of the designated volume of liquids in each metering chamber [5] . (iii) Centrifugal force with 1400 RPM was applied to transfer liquids into each dilution chamber. Due to the Coriolis force, the sample transferred in the dilution chambers may not have a flat interface (see Figure S1 ). If needed, abrupt angular acceleration, deacceleration, or mechanical vibrations may be applied for There are three vents in total; two vents in the waste chambers are used for sample metering, and one vent in #1D is used for sample transfer. To generate a series of ten-fold serial dilutions, the sample is subject to the metering process, transfer from the metering chambers to the dilution chambers, mixing in each dilution chamber, and transfer of one-tenth of the sample volume from one dilution chamber to the next dilution chamber. Figure 4 shows the core working principle of our proposed device using both the centrifugal and vacuum-driven forces. Before usage, all PDMS devices were degassed in a vacuum chamber under~0.1 ATM overnight. (i) First, the sample and buffer were loaded into the device using a pipette. (ii) The liquid sample and buffer were metered by vacuum-driven flows: 8.96 µL (#1) for the sample containing blue dye; 8.07 µL (#2, #3, and #4) and 7.26 µL (#5) for the buffer containing red dye. Here, in order to achieve the same sample volume (~8 µL) of the dilution series, in the end, the first chamber has~10% more volume, and the last chamber has~10% less volume than the targeting sample volume in the metering process, considering the serial dilution process. Abrupt geometrical height/width differences in channels and chambers using phase-guide structures [36] enabled precise metering and aliquoting of the designated volume of liquids in each metering chamber [5] . (iii) Centrifugal force with 1400 RPM was applied to transfer liquids into each dilution chamber. Due to the Coriolis force, the sample transferred in the dilution chambers may not have a flat interface (see Figure S1 ). If needed, abrupt angular acceleration, deacceleration, or mechanical vibrations may be applied for smooth transition to the next process. With this RPM settings, there were always residues trapped in the capillary bridges and edges of the metering chambers. These trapped samples partially contribute to form a dead-end chamber, which can trigger vacuum-driven force to convey the sample in the later process. The trapped sample volumes had up to~0.2 µL each (see Figure S2 ). (iv) Loading ports were sealed with adhesive tape (e.g., 3M tape) to avoid contamination and sample evaporation. As in the previous process, the dead-end chamber was formed. Thus the sample can be triggered by a vacuum-driven force. One-tenth of its original liquid volume stored in the dilution chamber was metered with the assistance of phase-guide structures and transferred to the next dilution chamber across the transfer bridge by vacuum-driven pumping. This enables the concentration of the sample to be reduced by a factor of ten: that is, to one-tenth of the original concentration. (v) and (vi) Centrifugal force was applied to mix the sample with the buffer. (vii) This process was repeated four times to achieve a series of ten-fold serial dilutions ranging from 10 0 to 10 −4 in each dilution chamber. (viii) and (viii') The serial dilution process was completed. The images show the completed serial dilution with and without tapes. smooth transition to the next process. With this RPM settings, there were always residues trapped in the capillary bridges and edges of the metering chambers. These trapped samples partially contribute to form a dead-end chamber, which can trigger vacuum-driven force to convey the sample in the later process. The trapped sample volumes had up to ~0.2 μL each (see Figure S2 ). (iv) Loading ports were sealed with adhesive tape (e.g., 3M tape) to avoid contamination and sample evaporation. As in the previous process, the dead-end chamber was formed. Thus the sample can be triggered by a vacuum-driven force. One-tenth of its original liquid volume stored in the dilution chamber was metered with the assistance of phase-guide structures and transferred to the next dilution chamber across the transfer bridge by vacuum-driven pumping. This enables the concentration of the sample to be reduced by a factor of ten: that is, to one-tenth of the original concentration. (v) and (vi) Centrifugal force was applied to mix the sample with the buffer. (vii) This process was repeated four times to achieve a series of ten-fold serial dilutions ranging from 10 to 10 in each dilution chamber. (viii) and (viii') The serial dilution process was completed. The images show the completed serial dilution with and without tapes. Metering of liquids is achieved by vacuum-driven pumping and phase-guide structures ( Figure 5 and Video S1). First, the sample was loaded into inlet A and buffer into inlet B by manual pipetting. Gentle pressure was applied while loading the liquids, causing the sample or buffer to fill the whole metering chambers and the vents. Then, the liquid sample or buffer would stop at capillary valves but keep flowing into the dead-end waste chamber because of the vacuum-driven pumping in the degassed PDMS device. Here, the strong constraint at the phase-guide structure causes the liquid column to separate into two parts: one flowing into the waste chamber and the other retained inside the metering chamber. Metering of liquids is achieved by vacuum-driven pumping and phase-guide structures ( Figure 5 and Video S1). First, the sample was loaded into inlet A and buffer into inlet B by manual pipetting. Gentle pressure was applied while loading the liquids, causing the sample or buffer to fill the whole metering chambers and the vents. Then, the liquid sample or buffer would stop at capillary valves but keep flowing into the dead-end waste chamber because of the vacuum-driven pumping in the degassed PDMS device. Here, the strong constraint at the phase-guide structure causes the liquid column to separate into two parts: one flowing into the waste chamber and the other retained inside the metering chamber. The pressure difference across the liquid column is generated due to the gas solubility of degassed PDMS, driving liquids into the dead-end channel/chamber. Geometrical confinement by phase-guide structures would play a role in metering the liquids. P is the atmospheric pressure, is the pressure inside the chamber, is the pressure associated with degassed PDMS, and ∆ and ∆ are the capillary pressure of the capillary valves at the vent and the inlet, respectively. (d) 3D schematic view of phase-guide for one side of a PDMS layer. Various papers report several capillary valves, such as burst valves, retention valves, and triggering valves, for controlling a sample injection sequence in capillary microfluidics [34, 35] . In addition, our previous study [38] reported sequential injection in vacuumdriven microfluidics when a device had multiple inlets and vents connected with capillary valves. The triggering order could be well controlled by designing different geometric structures for each capillary valve. In this study, we designed a degassed PDMS device in which the capillary pressure across the capillary valve next to the vent with a rigid neck shape, ∆ , was always higher than that next to the inlet with a loose neck shape, ∆ . As a result, the vacuum-driven pumping would (1) first split the liquid at the phase-guide structure; (2) next, drag the detached liquid from the inlet and then from the vent, in sequence; and (3) finally, withdraw the liquid into the dead-end waste chamber. Centrifugal force was applied to convey metered liquids into each dilution chamber. To overcome the capillary pressure across the capillary valve placed between the metering chamber and the dilution chamber, the device was spun at an angular velocity, ω, higher than the burst angular velocity, : > . The driving pressure due to the centrifugal force, ∆ , exerted on the liquid column, whose advancing front-end and receding rear- The pressure difference across the liquid column is generated due to the gas solubility of degassed PDMS, driving liquids into the dead-end channel/chamber. Geometrical confinement by phase-guide structures would play a role in metering the liquids. P ATM is the atmospheric pressure, P gas is the pressure inside the chamber, P PDMS is the pressure associated with degassed PDMS, and ∆P cV and ∆P cI are the capillary pressure of the capillary valves at the vent and the inlet, respectively. (d) 3D schematic view of phase-guide for one side of a PDMS layer. Various papers report several capillary valves, such as burst valves, retention valves, and triggering valves, for controlling a sample injection sequence in capillary microfluidics [34, 35] . In addition, our previous study [38] reported sequential injection in vacuumdriven microfluidics when a device had multiple inlets and vents connected with capillary valves. The triggering order could be well controlled by designing different geometric structures for each capillary valve. In this study, we designed a degassed PDMS device in which the capillary pressure across the capillary valve next to the vent with a rigid neck shape, ∆P cV , was always higher than that next to the inlet with a loose neck shape, ∆P cI . As a result, the vacuum-driven pumping would (1) first split the liquid at the phase-guide structure; (2) next, drag the detached liquid from the inlet and then from the vent, in sequence; and (3) finally, withdraw the liquid into the dead-end waste chamber. Centrifugal force was applied to convey metered liquids into each dilution chamber. To overcome the capillary pressure across the capillary valve placed between the metering chamber and the dilution chamber, the device was spun at an angular velocity, ω, higher than the burst angular velocity, ω b : ω > ω b . The driving pressure due to the centrifugal force, ∆P d , exerted on the liquid column, whose advancing front-end and receding rear-end are located at distances r A and r R from the rotation center, can be described as below [39] : where ρ is the density of the liquid and ω is the angular velocity. In addition, the capillary pressure difference, ∆P c , between the advancing front-end and the receding rear-end of the liquid under equilibrium can be described by the Young-Laplace equation, as below [39, 40] : where ∆P cA and ∆P cR are the capillary pressure at the advancing front-end and at the receding rear-end. γ is the surface tension. θ * tA , θ * bA , θ * lA , and θ * rA are the contact angles of top, bottom, left, and right considering the expansion angle of the channel at the advancing front-end. θ tR , θ bR , θ lR , and θ rR are the contact angles of top, bottom, left, and right of the channel at the receding rear-end, respectively [39] . h and w are the height and the width of the channel at the advancing front-end. H and W are the height and the width of the channel at the receding rear-end. When the centrifugal driving pressure is higher than the capillary pressure difference, or the driving angular velocity is higher than the burst angular velocity, the liquid can overcome the capillary barrier and, thus, transfer to the dilution chamber. The driving and burst angular velocity, ω and ω b , can be calculated by: In our design, when ∆P c ∼ = 2186 Pa, the corresponding burst angular velocity was ω b ∼ = 131 rad s −1 , or 1248 RPM. During operation, we applied ω = 1400 RPM counterclockwise to ensure the loading of each metered liquid into each dilution chamber. Under experimental conditions, the residue was found to adhere to the edge parts of the metering chambers and the capillary valves; this is discussed later in the results and discussions section. Liquid transfer between neighboring chambers across the transfer bridge was achieved by vacuum-driven pumping with the assistance of phase-guide structures (Video S2). The trapped sample at capillary bridges between metering chambers and dilution chambers assisted in forming a dead-end, while the sample was transferring from confined phase-guide structures into the next dilution chambers. Here, the trapped sample at capillary bridges was controlled. This is discussed in the later section. The phase-guide structures would determine the volume of the liquid to be transferred. Here, the phase-guide structures were designed to meter and transfer one-tenth of its original volume from the previous dilution chamber into the next dilution chamber. For a ten-fold serial dilution, one part of the sample from the previous dilution chamber was mixed with nine parts of the buffer in the next dilution chamber. It should be mentioned that the liquid flowing into the dilution chamber from the metering chamber has a trajectory aimed at the left-side wall of the dilution chamber because of the effect of the Coriolis force ( Figure S1 ) [41] . Therefore, the liquid interface should be made parallel to the phase-guide structures placed in the middle of the dilution chamber. This is a critical step to further transfer an exact volume of the liquid across the transfer bridge by vacuum-driven flows. Before the partial transfer, an additional spin with a rapid acceleration-and-deacceleration or mechanical vibration, or both, may help not only to achieve a straight liquid interface in contact with the phase-guide structures but also to mix the liquid sample with the buffer better. Sample mixing is achieved with a partial contribution from the vortical flow, which leads to mixing in a micro-chamber due to Euler/inertial force from a continuous cyclic acceleration-and-deceleration under unidirectional rotation [42] [43] [44] . As reported by Ren et al. [43, 44] , a larger chamber, achieved by increasing the outer radius, height, or angular span of the chamber; a maximum rotation speed; and/or rapid acceleration-anddeacceleration would help to improve the mixing efficiency. For instance, the dilution chambers must be sufficiently thick to ensure efficient mixing. In our design, we used a chamber thickness of 420 µm to achieve mixing in less than a few minutes and to handle relatively large liquid volumes of~10 µL. In the device, the thickness of phase-guide structures was optimized to be 210 µm. In the operation procedure, a 1400 RPM counterclockwise rotation with up to 300 RPM/s cyclic acceleration and deacceleration for up to 3 min was applied to achieve uniform mixing. The device was fabricated using soft lithography to construct microfluidic channels, chambers, and phase-guide structures in PDMS. Two wafers were used to fabricate molds for the top layer and the bottom layer of the PDMS device, having symmetrical patterns, as shown in Figure 1 . The height of the channels and chambers was 210 µm, and the height of the phase-guide structures was 105 µm in each layer. First, molds were fabricated using a 3-inch silicon wafer (University Wafers, South Boston, MA, USA). The wafers were submerged into buffered hydrofluoric acid (BHF) at room temperature for 5 min to remove the native silicon dioxide layers. Next, the wafers were cleaned using acetone, then methanol, and finally rinsed with deionized water. Nitrogen blowing was then used to dry the surface. The wafers were placed on a hot plate at 120 • C for 5 min for complete dehydration. A negative photoresist SU-8 2050 (Micro-Chem Corp, Newton, MA, USA) was spin-coated on top of each wafer using a spin coater (CEE-200; Brewer Science, Rolla, MO, USA). The wafers were then soft-baked at 65 • C for 5 min and then at 95 • C for 30 min. The wafers were aligned using an infrared mask aligner and exposed to ultra-violet (UV) light using a first mask containing the channels and chambers. The wafers were hard-baked at 65 • C for 5 min and 95 • C for 30 min. To achieve the desired thickness of the channels and chambers and form phase-guide structures, the second set of spin coating, soft bake, UV light exposure, and hard bake was performed for each wafer using a second mask containing the phase-guide structures as well as the channels and chambers. Then, the wafers were rinsed in a SU-8 developer for 17 min to remove the unexposed photoresist, followed by isopropyl alcohol (IPA) rinsing. Finally, the wafers were blown dry with compressed nitrogen air to remove IPA. To protect the mold and facilitate the release of PDMS from the mold, a hydrophobic release agent was coated on the surface by exposing the mold surface to hexamethyldisilazane (HMDS) vapor. After generating the mold structures, the PDMS base and curing agent were mixed at the ratio of 10:1 and then degassed in a vacuum chamber to remove air bubbles. Next, liquid PDMS was poured onto the wafer mold and cured at 80 • C for 3 h. After cooling, the PDMS replicas were peeled from the mold, and the inlet and vent ports were punched using punch biopsy. The bottom PDMS and a glass slide substrate were treated with oxygen plasma and then aligned and placed in contact for a permanent bond. The top PDMS was aligned and placed in contact with a bottom PDMS to form the device. Keratinocytes were isolated from neonatal (1 to 3-day-old neonates) foreskin tissues obtained from John R. Oishei Children's Hospital, Buffalo, NY, in accordance with the guidelines of this IRB of John R. Oishei Children's Hospital. Skin samples were washed three times with phosphate-buffered saline (PBS), cut into small pieces (0.5 cm × 0.5 cm), and enzymatically digested with dispase II protease (Sigma, St. Louis, MO, USA) at 4 • C for 12-18 h. Using fine forceps, the epidermis was separated from the dermis and further treated with trypsin-EDTA (0.25%) ( , and 10 ng/mL epidermal growth factor (EGF, added after 3 days of seeding; BD Biosciences, Franklin Lakes, NJ, USA). After 7-10 days of the culture, feeder cells were removed using versene treatment and keratinocytes were harvested using trypsin-EDTA (0.25%); neutralized with PBS containing 10% FBS, and further cultured on collagen type I-coated tissue culture plates (10 µg collagen type I per cm 2 ; BD Biosciences, Franklin Lakes, NJ, USA) in keratinocyte serum-free growth medium (KSFM, Epilife medium with human keratinocyte growth supplement; Life Technologies, Carlsbad, CA, USA). Total RNA was isolated from keratinocytes using the RNeasy kit (Qiagen, Germantown, MD, USA) according to the manufacturer's instructions. Subsequently, cDNA was synthesized from total RNA using QuantiTect reverse transcription kit (Qiagen, Germantown, MD, USA). First, a microfluidic device was cleaned with RNase Away (Thermo Scientific, Waltham, MA, USA) to wash out ribonuclease, which catalyzes RNA degradation, followed by cleaning with nuclease-free water to remove the residue of RNase Away. Then, the cDNA sample was loaded into inlet A and nuclease-free water into inlet B. After completing the serial dilution in a device using the process shown in Figure 3 , diluted samples were collected from each dilution chamber (#1D through #5D) using fine needles. The performance of our proposed device was verified by qPCR using those diluted samples. Amplification of the diluted cDNA samples was performed using a real-time PCR detection system (CFX96; Bio-Rad, Hercules, CA, USA) with the SYBR green mix (Invitrogen, Carlsbad, CA, USA) according to the manufacturer's instructions. qPCR is a simple and powerful method allowing in vitro amplification of DNA fragments through a succession of three incubation steps at different temperatures [45, 46] . In this study, a hot start (600 s at 95 • C) was followed by 40 cycles of denaturing (15 s at 95 • C), annealing (30 s at 60 • C), and extension (30 s at 60 • C). In fact, using this ten-fold serial dilution, we can study the expression of RPL32 over high dynamic range ten-fold serial dilutions; however, this was not the main focus of this study. After qPCR cycling, the specificity of each product was verified using melt curve analysis, which is frequently used as a diagnostic tool for assessing qPCR assays. For manually diluted samples, cDNA was diluted using 1 µL of cDNA along with 9 µL of nuclease-free water to achieve the same ten-fold serial dilution in each step. After completing the operating process, samples were expected to have the same amount of volume in each dilution chamber with about 8 µL. However, the measured volumes showed a slight deviation, as shown in Figure 6a . One possible reason was that the loaded sample volumes in each dilution chamber were not as accurate as of the target values. Right after the step shown in Figure 4iii , the liquids loaded in each dilution chamber were retrieved by fine needles and measured using adjustable volume micropipette aspiration in triplicate, as shown in Figure 6b . The errors may partly arise when the liquids adhere to the chamber edge of the capillary valve between the metering chamber and the dilution chamber ( Figure S2 ). Here, for clarification, more than four test devices underwent step (i) to step (viii), and sample volume was measured for Figure 6a . More than another four sets of the test devices underwent step (i) to (iii), and sample volume was measured for Figure 6b . Additionally, non-uniform chamber thickness over the device area related to microfabrication errors may be a possible factor underlying the observed deviation. However, the errors were still acceptable for performing qPCR as proof-of-concept verification. After completing the operating process, samples were expected to have the same amount of volume in each dilution chamber with about 8 μL. However, the measured volumes showed a slight deviation, as shown in Figure 6a . One possible reason was that the loaded sample volumes in each dilution chamber were not as accurate as of the target values. Right after the step shown in Figure 4iii , the liquids loaded in each dilution chamber were retrieved by fine needles and measured using adjustable volume micropipette aspiration in triplicate, as shown in Figure 6b . The errors may partly arise when the liquids adhere to the chamber edge of the capillary valve between the metering chamber and the dilution chamber ( Figure S2 ). Here, for clarification, more than four test devices underwent step (i) to step (viii), and sample volume was measured for Figure 6a . More than another four sets of the test devices underwent step (i) to (iii), and sample volume was measured for Figure 6b . Additionally, non-uniform chamber thickness over the device area related to microfabrication errors may be a possible factor underlying the observed deviation. However, the errors were still acceptable for performing qPCR as proof-of-concept verification. Figure 4iii ). Digital micropipette aspiration was used to measure the sample volume. More than four test devices were used for measuring for (a) and (b), respectively. The insets indicate in which process the samples were collected for measuring. Although fluorescent analysis is widely used for serial dilution analysis, there are limitations in detecting a wide range of concentrations due to background noises [2, 47] . As an alternative, a qPCR assay can be used to verify the performance of the serial dilution because it provides an unusually large dynamic range across several orders of magnitude. For proof of concept, in this study, qPCR was performed after preparing a series of tenfold serial dilutions of the cDNA sample using a device as previously described, as well as by manual pipetting. The measurement of each concentration point was performed in triplicate. Figure 7 shows plots of the measured cycle quantification values, , against the concentrations of serially diluted cDNA sample obtained by using the proposed microfluidic device and manual pipetting. Here, is a PCR thermal cycle number at which the reaction curve intersects with a threshold line, such as background fluorescence [45] , and the values show a linear relationship with the sample concentration across several Figure 4iii ). Digital micropipette aspiration was used to measure the sample volume. More than four test devices were used for measuring for (a) and (b), respectively. The insets indicate in which process the samples were collected for measuring. Although fluorescent analysis is widely used for serial dilution analysis, there are limitations in detecting a wide range of concentrations due to background noises [2, 47] . As an alternative, a qPCR assay can be used to verify the performance of the serial dilution because it provides an unusually large dynamic range across several orders of magnitude. For proof of concept, in this study, qPCR was performed after preparing a series of ten-fold serial dilutions of the cDNA sample using a device as previously described, as well as by manual pipetting. The measurement of each concentration point was performed in triplicate. Figure 7 shows plots of the measured cycle quantification values, C q , against the concentrations of serially diluted cDNA sample obtained by using the proposed microfluidic device and manual pipetting. Here, C q is a PCR thermal cycle number at which the reaction curve intersects with a threshold line, such as background fluorescence [45] , and the C q values show a linear relationship with the sample concentration across several orders of magnitude. The result showed a strong linear relationship between the C q values and the ten-fold serial dilutions of cDNA sample ranging from 10 0 to 10 −4 , with R 2 > 0.99 obtained using the line of best-fit, which was equivalent to that for the cDNA sample prepared by manual pipetting. The C q slope of the microfluidic results is not as sharp as the one from the manual results. Some of the possible reasons are that; the volume of cDNA and buffer were not accurate (e.g., larger) compared with what we expected in this qPCR test as well, considering the volume analysis results in Figure 5 , insufficient mixing, etc. resulting the deviation. To ensure the validity, repeating the qPCR tests to add error bars are needed in the future study. Micromachines 2021, 12, x FOR PEER REVIEW 12 of 15 orders of magnitude. The result showed a strong linear relationship between the values and the ten-fold serial dilutions of cDNA sample ranging from 10 to 10 , with > 0.99 obtained using the line of best-fit, which was equivalent to that for the cDNA sample prepared by manual pipetting. The slope of the microfluidic results is not as sharp as the one from the manual results. Some of the possible reasons are that; the volume of cDNA and buffer were not accurate (e.g., larger) compared with what we expected in this qPCR test as well, considering the volume analysis results in Figure 5 , insufficient mixing, etc. resulting the deviation. To ensure the validity, repeating the qPCR tests to add error bars are needed in the future study. Because the liquids were partially driven by gas-solubility-based vacuum-driven pumping, the degassed PDMS without additional coating would lose pumping ability after a certain time. As reported by several papers [11, 13, 48, 49] , the flow rate using the degassed PDMS decreases after the device is exposed to the atmosphere. The characteristic time, τ, can be estimated by Fick's law [12] : where L is the length between the top surface of the chamber and the outer surface of the PDMS device and D is the diffusion coefficient of air in PDMS. Therefore, the diminishing characteristic time, τ, depends on the geometry of the device (e.g., the length, thickness, or volume of the PDMS device, and the surface area exposed to the atmosphere allowing air diffusion) and the property of the PDMS material (e.g., the mixing ratio of PDMS base and curing agent [50] ). For instance, if = 5 mm and = 3.4 × 10 m s , the diminishing characteristic time would be ≈ 2 h. Currently, the total operation time for the ten-fold serial dilution with 7 to 10 μL in each chamber was 45 min. Possible approaches to increase the ability of steady vacuum-driven pumping over a longer period of time are to coat the outer surface of the PDMS device with sealing materials (e.g., wax [48] or tape [13] ) and to construct a thicker PDMS device [11, 13] . The total operation time seems to be restricted by relatively slow vacuum-driven pumping (e.g., a few nL s ) [11, 13] . During the metering process, more than 5 μL of excess liquid buffer was driven to the buffer waste chamber with close to 10 nL s , which would decay quickly over time. Additionally, about 0.9 μL of the liquid sample was transferred across the transfer bridge, with even slower flow rates, four times. In the future, in order to reduce the total operation time, the metering process will be replaced by centrifugal pumping rather than vacuum- Because the liquids were partially driven by gas-solubility-based vacuum-driven pumping, the degassed PDMS without additional coating would lose pumping ability after a certain time. As reported by several papers [11, 13, 48, 49] , the flow rate using the degassed PDMS decreases after the device is exposed to the atmosphere. The characteristic time, τ, can be estimated by Fick's law [12] : where L is the length between the top surface of the chamber and the outer surface of the PDMS device and D is the diffusion coefficient of air in PDMS. Therefore, the diminishing characteristic time, τ, depends on the geometry of the device (e.g., the length, thickness, or volume of the PDMS device, and the surface area exposed to the atmosphere allowing air diffusion) and the property of the PDMS material (e.g., the mixing ratio of PDMS base and curing agent [50] ). For instance, if L = 5 mm and D = 3.4 × 10 −9 m 2 s −1 , the diminishing characteristic time would be τ ≈ 2 h. Currently, the total operation time for the ten-fold serial dilution with 7 to 10 µL in each chamber was 45 min. Possible approaches to increase the ability of steady vacuum-driven pumping over a longer period of time are to coat the outer surface of the PDMS device with sealing materials (e.g., wax [48] or tape [13] ) and to construct a thicker PDMS device [11, 13] . The total operation time seems to be restricted by relatively slow vacuum-driven pumping (e.g., a few nL s −1 ) [11, 13] . During the metering process, more than 5 µL of excess liquid buffer was driven to the buffer waste chamber with close to 10 nL s −1 , which would decay quickly over time. Additionally, about 0.9 µL of the liquid sample was transferred across the transfer bridge, with even slower flow rates, four times. In the future, in order to reduce the total operation time, the metering process will be replaced by centrifugal pumping rather than vacuum-driven pumping [2, 3] . Using tapes to seal the inlet and vent ports is inconvenient; this would be resolved by incorporating active or passive valves with smart sealing functions for vacuum-driven pumping. In the test, the trapped sample in the capillary bridges was used to assist in forming a dead-end channel. The trapped residues were targeted to be controlled by, such as employing small pockets at the edges of the metering chambers and applying slightly higher RPM than critical burst frequency. However, improving the robustness is required, and in the future, we plan to implement valves instead. Applying high RPM on a device is a challenge, as a device is made from a thick PDMS slab, and the substrate is not a round shape in the experiment. A robust symmetry platform will be developed in a future study. The concept of the proposed device can be used to achieve different dilution ratios by altering its geometry (e.g., volume of the metering chambers, phase-guide and the dilution chambers). Here, achieving the desired thickness is a necessary in fabrication by avoiding the edge beads. Furthermore, we would integrate an on-chip qPCR module with the serial dilution module by devising a method to fill the empty space in each chamber with oils to avoid evaporation and contamination during on-chip thermal cycling. In conclusion, we propose a new serial dilution method utilizing centrifugal and vacuum-driven force. The combination of two actuation methods could complement the drawbacks of each. A qPCR assay was carried out to verify the performance of the on-chip serial dilution, showing strong linearity over the large dynamic range across several orders of magnitude. Even though further improvements are needed for accurate volume control, reduction in the total operation time, a user-friendly sealing method, and additional onchip integrations, the proposed device demonstrates feasibility for promising on-chip serial dilution applications. Furthermore, in addition to centrifugal pumping, this vacuumdriven pumping could easily be integrated with other types of pumping for applications relating to various novel on-chip biological or chemical analyses in a hybrid manner. Supplementary Materials: The following are available online at https://www.mdpi.com/article/10 .3390/mi12050482/s1, Supplemental Documents, Figure S1 : Coriolis force effect, Figure S2 : Volume analysis and its scheme, Video S1: Sample Metering, Video S2: Sample Transfer. Endothelial cell polarization and chemotaxis in a microfluidic device Automated serial dilutions for high-dynamic-range assays enabled by fill-level-coupled valving in centrifugal microfluidics Fully integrated dilution series generation on a laboratory centrifuge Ultrasensitive microfluidic solid-phase ELISA using an actuatable microwell-patterned PDMS chip A power-free, parallel loading microfluidic reactor array for biochemical screening Automatic liquid handling for life science: A critical review of the current state of the art Product review: Liquid handling: Dispensing reliability Automation Workstation for Cell-Based Assays Phaseguide-assisted blood separation microfluidic device for point-of-care applications Detection of COVID-19: A review of the current literature and future perspectives Vacuum-driven power-free microfluidics utilizing the gas solubility or permeability of polydimethylsiloxane (PDMS) Syringe-assisted point-of-care micropumping utilizing the gas permeability of polydimethylsiloxane. Microfluid. Nanofluid Passive micropumping in microfluidics for point-of-care testing Capillary microfluidics in microchannels: From microfluidic networks to capillaric circuits Microfluidic network-based combinatorial dilution device for high throughput screening and optimization SERS-based immunoassay using a gold array-embedded gradient microfluidic chip Design of pressure-driven microfluidic networks using electric circuit analogy Simultaneous detection of duplex DNA oligonucleotides using a SERS-based micro-network gradient chip Microfluidic concentrationon-demand combinatorial dilutions A compact microfluidic gradient generator using passive pumping. Microfluid. Nanofluid Abnormal Liquid Chasing Effect in Paper Capillary Enables Versatile Gradient Generation on Microfluidic Paper Analytical Devices Method to prevent backflow in a capillarity network for bioassays: Exploiting time constant ratios Influence of surface tension-driven network parameters on backflow strength A robust, portable and backflow-free micromixing device based on both capillary-and vacuum-driven flows Passive microfluidic control of two merging streams by capillarity and relative flow resistance A radial microfluidic platform for higher throughput chemotaxis studies with individual gradient control Review on pneumatic operations in centrifugal microfluidics Active pneumatic control of centrifugal microfluidic flows for lab-on-a-chip applications A compact, syringe-assisted, vacuum-driven micropumping device Flow analysis on microcasting with degassed polydimethylsiloxane micro-channels for cell patterning with cross-linked albumin Immunoassay on a power-free microchip with laminar flow-assisted dendritic amplification Power-free sequential injection for microchip immunoassay toward point-of-care testing Power-free poly (dimethylsiloxane) microfluidic devices for gold nanoparticlebased DNA analysis Autonomous microfluidic capillary system Capillarics: Pre-programmed, self-powered microfluidic circuits built from capillary elements Phaseguides: A paradigm shift in microfluidic priming and emptying A new fabrication process for uniform SU-8 thick photoresist structures by simultaneously removing edge bead and air bubbles Backflow-assisted sequential injection in vacuum-driven power-free microfluidic device Burst valves for commercial microfluidics: A critical analysis How the capillary burst microvalve works Invited Review Article: Review of centrifugal microfluidic and bio-optical disks Batch-mode mixing on centrifugal microfluidic platforms Vortical flow and mixing in rotating milli-and micro-chambers Numerical and experimental investigation on flow and mixing in batch-mode centrifugal microfluidics Centrifugal microfluidic system for a fully automated N-fold serial dilution Hermetic encapsulation of negative-pressure-driven PDMS microfluidic devices using paraffin wax and glass Improved biocompatibility of parylene-C films prepared by chemical vapor deposition and the subsequent plasma treatment PDMS membranes with tunable gas permeability for microfluidic applications The authors acknowledge Hyun Jin Yoo (Department of Integrative Engineering at Chung-Ang University, South Korea) for providing assistance and useful discussion during the qPCR process. The authors acknowledge Davis Hall Electrical Engineering Cleanroom staff for their support with fabrication. The authors declare no conflict of interest.