key: cord-0017371-y6kj7ukc authors: Pulickal, Tobyson; Helms, Thomas M.; Perings, Christian A. title: Der Wearable Kardioverter-Defibrillator als Diagnostikum: Fallbeispiel aus dem telemedizinischen Alltag date: 2021-05-12 journal: Herzschrittmacherther Elektrophysiol DOI: 10.1007/s00399-021-00769-0 sha: 49a5ac283c6eb8bad40fd066500742c8dc613d53 doc_id: 17371 cord_uid: y6kj7ukc Telemedical care can point out new applications of already established therapeutics such as a wearable cardioverter–defibrillator (WCD) and improve the quality of care for chronically ill patients with heart failure through improved management of data derived from this device. The current case report describes the clinical course of a 71-year-old man, who was treated with a WCD in accordance with the current guidelines until a final decision was made about ICD implantation, after acute cardiac decompensation and lately diagnosed severe decrease of left ventricular function in the context of ischaemic cardiomyopathy. The data collected by the WCD were evaluated in a structured way via a telemedicine centre (TMC) and recurrence of the previously known paroxysmal atrial fibrillation (AF) was discovered. This made it possible to treat the paroxysmal AF, before cardiac decompensation happened again by adjusting the medication and early initiation of pulmonary vein isolation (PVI). This case exemplifies the usefulness of structured telemedical intervention, which makes it possible to meaningfully supplement established concepts of patient care, improve existing concepts and significantly improve patient care. In dem vorliegenden Fall soll eine solche telemedizinisch-assistierte Intervention mit Hilfe einer WCD der Fa. Zoll in Verbindung mit einem TMZ vorgestellt werden, bei welchem die zusätzlichen Monitoring-Fähigkeiten der WCD einerseits und andererseits die telemedizinische Intervention jenseits der bloßen Datenakquise dargestellt werden. Der betrachtete Patient ist zum Zeitpunkt der Intervention in unserem Krankenhaus (Mai bis Juli 2020) 71 Jahre alt, männlichen Geschlechts und nicht mehr berufstätig. Vorbekannt war eine dialysepflichtige Niereninsuffizienz seit > 1 Jahr auf dem Boden eines kardiorenalen Syndroms, eine schwere koronare Dreigefäßerkrankung, eine sauerstoffpflichtige chronischobstruktive Lungenerkrankung (COPD) und ein paroxysmales Vorhofflimmern (VHF), welches mittels Marcumar antikoaguliert wurde. Zum Aufnahmezeitpunktam 17.05.2020 zeigte sich der Patient in einem guten Ernährungs-bei gleichzeitig reduziertem Allgemeinzustand (. Abb. 1). Es Hiernach wurde der Patient überwacht, wobei sich wieder ein stabiler Sinusrhythmus zeigte. Da die hochgradig eingeschränkte Pumpfunktion persistierte, wurde eine Versorgung mit einer WCD der Fa. Zoll initiiert und die Herzinsuffizienzmedikation den aktuellen Leitlinien entsprechend optimiert [8] . Gleichzeitig erfolgte die Registrierung des Patienten im "Westdeutschen Zentrum für angewandte Telemedizin (WZAT)" als DGK-zertifiziertes TMZ, welches sich fortan im Rahmen einer Kooperation mit der Fa. Zoll um das ambulante Management der durch die WCD ermittelten Vitaldaten und das entsprechende ambulante Patientenmanagement kümmerte. Am 13.06.2020 erfolgte schließlich die Entlassung in die Häuslichkeit. Im Rahmen von täglichen digitalen Visiten wurden die übermittelten Vitalwerte der WCD durch die Medizinischen Fachangestellten (MFA) und die im TMZ tätigen Ärzte vidiert. Zudem war der Patient angehalten, selbstständig drei Mal täglich ein EKG mit Hilfe der WCD aufzuzeichnen. Insbesondere zu Beginn der WCD-Versorgung benötigte der Patient häufiger telefonische Unterstützung im Umgang mit der WCD, da ihm insbesondere das Anlegen schwerfiel und somit häufige akustische Alarme provoziert wurden. Durch das Monitoring der Tragezeit und der daraus resultierenden telefonischen Kontaktaufnahmen konnte trotz der beschriebenen Probleme eine hohe Compliance mit einer durchschnittlichen Tragezeit von über 22 h/Tag erreicht werden. Daneben konnte in den übermittelten EKGs ein Wiederauftreten von VHF dokumentiert werden (. Abb. 2). Da darüber hinaus die durchschnittliche Herzfrequenz > 100/min in 24 h und sich eine in der Detailansicht akzelerierende Tendenz zeigte (. Abb. 3), wurde dem Patienten zunächst eine Erhöhung der bereits bestehenden Betablockertherapie empfohlen. Zudem wurde der Patient wieder an unsere Klinik zurück überwiesen mit der Bitte einer Reevaluation der Frequenzbzw. des Versuchs einer Rhythmuskontrolle. Aufgrund der HI wurde unter prognostischen Gesichtspunkten eine PVI terminiert und erfolgreich durchgeführt. Patienten mit einer HI sind komplex in der Versorgung. Neben der Herausforderung im Hinblick auf die optimale Dosierung der durch die Leitlinien empfohle-nenPharmakotherapie [8] isteininMetaanalysen nachgewiesener positiver Effekt im Hinblick auf Interventionen zu erfassen, welche mit dem Ziel einer adäquaten Adhärenz hinsichtlich Medikamenteneinnahme und Dossierung durchgeführt worden sind [9] . Daher ist der Ansatz einer fortwährenden Überwachung als sinnvolles Ziel anzusehen. Das wie in dem vorgestellten Fallbeispiel vorkommende VHF kann im Rahmen einer bereits bestehenden HI die Prognose verschlechtern [10] , wobei mittlerweile wissenschaftliche Evidenz aus der CASTLE-AF-Studie existiert, dass eine PVI bei geeigneten Patienten einen Vorteil hinsichtlich Hospitalisation und Verschlechterung der HI erbringen kann [11] . Daneben ist eine Kontrolle der Herzfrequenz im Rahmen der HI sinnvoll, wobei die optimale Herzfrequenz für Patienten mit HI und VHF unklar ist und in den aktuellen Leitlinien zwischen 70 und 100/min angegeben wird, wohingegen bei Patienten mit HI und Sinusrhythmus eine Frequenz von < 70/min als Ziel erachtet wird [8, 12] . Dies illustriert einmal mehr die Notwendigkeit einer individualisierten Diagnostik und Therapie im Kollektiv der Patienten mit HI. Die Verwendung einer WCD mit erweiterten diagnostischen Funktionen als Mittel zur Überwachung eben dieses Kollektivs ist bereits Gegenstand wissenschaftlicher Untersuchungen und hat das Potenzial, den Anteil nicht adäquat therapierter Patienten in einem mit der WCD versorgten Kollektiv aufzuzeigen [13] , so dass diese einer Anpassung ihrer Therapie zugeführt werden können. Neben der reinen Rhythmusüberwachung sind Beschleunigungssensoren implementiert, welche die Erfassung verschiedener weiterer Parameter wie "Gehstrecke" oder "6-Minuten-Gehtest" ermöglichen, die sich für die Verlaufs- Herzschr Elektrophys https://doi.org/10.1007/s00399-021-00769-0 © Der/die Autor(en) 2021 Tragbare Defibrillator-Weste · Telemedizin · Herzinsuffizienz · Pulmonalvenenisolation · Prognoseverbesserung The wearable cardioverter defibrillator as diagnostic tool. Case report from remote monitoring daily practice Abstract Telemedical care can point out new applications of already established therapeutics such as a wearable cardioverter-defibrillator (WCD) and improve the quality of care for chronically ill patients with heart failure through improved management of data derived from this device. The current case report describes the clinical course of a 71-year-old man, who was treated with a WCD in accordance with the current guidelines until a final decision was made about ICD implantation, after acute cardiac decompensation and lately diagnosed severe decrease of left ventricular function in the context of ischaemic cardiomyopathy. The data collected by the WCD were evaluated in a structured way via a telemedicine centre (TMC) and recurrence of the previously known paroxysmal atrial fibrillation (AF) was discovered. This made it possible to treat the paroxysmal AF, before cardiac decompensation happened again by adjusting the medication and early initiation of pulmonary vein isolation (PVI). This case exemplifies the usefulness of structured telemedical intervention, which makes it possible to meaningfully supplement established concepts of patient care, improve existing concepts and significantly improve patient care. Wearable defibrillator vest · Telemedicine · Heart failure · Pulmonary vein isolation · Prognosis improvement beobachtung von HI-Patienten eigenen. Diese Verlaufsparameter müssen nicht mehr im Krankenhaus, sondern können in der eigenen Lebenswirklichkeit durchgeführt werden [14, 15] . Daneben findet sich auch neben temporären Devices wie der WCD ebenso für bereits im Rahmen der leitliniengerechten Versorgung implantierten dauerhaften Devices, welche telemedizinfähig sind, ein positiver Effekt auf das Outcome [16] , wenn diese mit einer telemedizinischen Versorgung kombiniert worden sind. Die in dem vorgestellten Fallbeispiel erhobenen Rhythmusdaten über die WCD sind in der klinischen Praxis bereits vorhanden, doch mangelt es oft an Strukturen, die eine geordnete Interpretation und Reaktion auf die empfangenen Daten zeigen. Zudem lebt ein System wie die WCD von einer ausreichenden Compliance, da es sonst nicht im Sinne eines Therapeutikums wirken kann [17] . Beide Anforderungen konnten in unserem Fallbeispiel durch die Mitversorgung bzw. die Intervention des TMZ erreicht werden. Dies zeigt, dass die telemedizinische Versorgung einer gewissen Struktur und Qualität bedarf, um entsprechende Ergebnisse zu erzielen [18, 19] . Dass Telemedizin jenseits des auswertenden einen manifesten therapeutischen Einfluss auf Mortalität und Morbidität haben kann, zeigte sich zuletzt in einer Nachbeobachtung des TIM-HF2-Kollektivs nach Beendigung der telemedizinischen Versorgung. Hierbei war nämlich der positive Effekt der telemedizinischen Versorgung hinsichtlich Mortalität und Morbidität verschwunden [20] . Aufgrund der technischen Beschränkung der WCD und der Unfähigkeit, Rhythmusereignisse unterhalb der programmierten VT-Schwelle zu detektie-ren, wären die in dem Fallbeispiel erhobenen Daten eines grenzwertig schnellen VHF ohne eine aktive Überwachung der eingehenden Vitalwerte und ohne ein regelmäßig durch den Patienten angefertigtes EKG mit entsprechender Interpretation durch ein TMZ nicht auffällig geworden und hätten keine Anpassung der Therapie ausgelöst. Ein System wie die WCD könnte in Zukunft nicht nur anhand der adäquaten Schocks beurteilt werden, sondern in Kombination mit strukturierter Tele-medizin auch nach deren Fähigkeit, sensorische Daten zu liefern, durch die eine bessere Versorgung immer komplexer werdender Patienten möglich ist. Daher ist eine regelhafte Kombination eines solchen Systems mit einer strukturierten telemedizinischen Mitversorgung, wie in dem dargestellten Fallbeispiel, zielführend in Bezug auf eine verbesserte Patientenversorgung. ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC) Use of the wearable cardioverter defibrillator in highrisk cardiac patients: data from the prospective registry of patients using the Wearable Cardioverter Defibrillator (WEARIT-II registry) Thewearable cardioverter-defibrillator: current technology and evolving indications Wearable cardioverter-defibrillator after myocardial infarction Wearable cardioverter-defibrillator therapy for the prevention of sudden cardiac death: a systematic review and meta-analysis Effectiveness of telemedicine systems for adults with heart failure: a meta-analysis of randomized controlled trials Efficacy of telemedical interventional management in patients with heart failure (TIM-HF2): a randomised, controlled, parallel-group, unmasked trial ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) Medication adherence interventions improve heart failure mortality and readmission rates: systematic review and meta-analysis of controlled trials Prognostic relevance of atrial fibrillation in patients with chronic heart failure on longterm treatment with beta-blockers: results from COMET Catheter ablation for atrial fibrillation with heart failure Heart rate, beta-blocker use, and outcomes of heart failure with reduced ejection fraction Achieving guideline-directed heart rate ControlEarly posthospitalization Teleaccelerometry as a novel technique for assessing functional status in patients with heart failure: feasibility, reliabilityandpatientsafety Prognostic value of serial six-minute walk tests using tele-accelerometry in patients with chronic heart failure: a pre-specified sub-study of the TIM-HF-Trial Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial Impact of wearable cardioverter-defibrillator compliance on outcomes in the VEST trial: as-treated and per-protocol analyses Grundlegende Strukturmerkmale eines kardiologischen Telemedizinzentrums für Patienten mit Herzinsuffizienz und implantierten Devices, Herzrhythmusstörungen und erhöhtem Risiko für den plötzlichen Herztod: Empfehlungen der Arbeitsgruppe 33 Telemonitoring in der Deutschen Gesellschaft für Kardiologie Positionspapier Telemonitoring: Von den Nukleusmitgliedern der AG33 Telemonitoring in der DGK und assoziierten Mitgliedern Mortality and morbidity 1 year after stopping a remote patient management intervention: extended follow-up results from the telemedical interventional management in patients with heart failure II (TIM-HF2) randomised trial