key: cord-0016793-xbm1jjx0 authors: Bonifazi, Matteo; Romitti, Federica; Busana, Mattia; Palumbo, Maria Michela; Steinberg, Irene; Gattarello, Simone; Palermo, Paola; Saager, Leif; Meissner, Konrad; Quintel, Michael; Chiumello, Davide; Gattinoni, Luciano title: End-tidal to arterial PCO(2) ratio: a bedside meter of the overall gas exchanger performance date: 2021-04-19 journal: Intensive Care Med Exp DOI: 10.1186/s40635-021-00377-9 sha: 9e105141af5e9f43c4b280247a16d95eba7eeae5 doc_id: 16793 cord_uid: xbm1jjx0 BACKGROUND: The physiological dead space is a strong indicator of severity and outcome of acute respiratory distress syndrome (ARDS). The “ideal” alveolar PCO(2), in equilibrium with pulmonary capillary PCO(2), is a central concept in the physiological dead space measurement. As it cannot be measured, it is surrogated by arterial PCO(2) which, unfortunately, may be far higher than ideal alveolar PCO(2), when the right-to-left venous admixture is present. The “ideal” alveolar PCO(2) equals the end-tidal PCO(2) (P(ET)CO(2)) only in absence of alveolar dead space. Therefore, in the perfect gas exchanger (alveolar dead space = 0, venous admixture = 0), the P(ET)CO(2)/PaCO(2) is 1, as P(ET)CO(2), P(A)CO(2) and PaCO(2) are equal. Our aim is to investigate if and at which extent the P(ET)CO(2)/PaCO(2), a comprehensive meter of the “gas exchanger” performance, is related to the anatomo physiological characteristics in ARDS. RESULTS: We retrospectively studied 200 patients with ARDS. The source was a database in which we collected since 2003 all the patients enrolled in different CT scan studies. The P(ET)CO(2)/PaCO(2), measured at 5 cmH(2)O airway pressure, significantly decreased from mild to mild–moderate moderate–severe and severe ARDS. The overall populations was divided into four groups (~ 50 patients each) according to the quartiles of the P(ET)CO(2)/PaCO(2) (lowest ratio, the worst = group 1, highest ratio, the best = group 4). The progressive increase P(ET)CO(2)/PaCO(2) from quartile 1 to 4 (i.e., the progressive approach to the “perfect” gas exchanger value of 1.0) was associated with a significant decrease of non-aerated tissue, inohomogeneity index and increase of well-aerated tissue. The respiratory system elastance significantly improved from quartile 1 to 4, as well as the PaO(2)/FiO(2) and PaCO(2). The improvement of P(ET)CO(2)/PaCO(2) was also associated with a significant decrease of physiological dead space and venous admixture. When PEEP was increased from 5 to 15 cmH(2)O, the greatest improvement of non-aerated tissue, PaO(2) and venous admixture were observed in quartile 1 of P(ET)CO(2)/PaCO(2) and the worst deterioration of dead space in quartile 4. CONCLUSION: The ratio P(ET)CO(2)/PaCO(2) is highly correlated with CT scan, physiological and clinical variables. It appears as an excellent measure of the overall “gas exchanger” status. The physiological dead space, which includes both the anatomical and alveolar dead space, is a strong indicator of severity and outcome of acute respiratory distress syndrome (ARDS) [1, 2] . The computation of the physiological dead space is based on the dilution of the ideal alveolar PCO 2 (PACO 2 ). This ideal PCO 2 , introduced by Riley, cannot be measured directly and it is assumed to be equal to the capillary PCO 2 (PcCO 2 ) [3] which leaves the ventilated/perfused pulmonary units [4] . As the PcCO 2 cannot be measured directly, the arterial PCO 2 (PaCO 2 ) is assumed to be its surrogate. Therefore, the assumption on which the physiological dead space is computed is that PACO 2 , PcCO 2 and PaCO 2 have identical values. While this is nearly correct in the normal lung, in the diseased lung, as in ARDS, the PaCO 2 is higher than PcCO 2 and PACO 2 due to the presence of venous admixture (in Riley's model, the fraction of blood which flows through "non-aerated lung regions" maintaining the same PO 2 and PCO 2 of the mixed venous blood). Consequently, PaCO 2 is the result of the weighted average of blood coming from the ideal compartment (PcCO 2 ) and of mixed venous PCO 2 (PvCO 2 ) [5] . , It is therefore easy to understand why the venous admixture, i.e., a variable which measures the oxygenation impairment, has an effect on variables which describe the wasted ventilation. To compute the alveolar dead space, we may assume that the end-tidal CO 2 (P ET CO 2 ) is representative of the actual alveolar gases. In this case, the P ET CO 2 is lower than the PACO 2 depending on the amount of alveolar dead space. The measurement of the P ET CO 2 is easily performed in intensive care. Therefore, the alveolar dead space may be derived as follows: As the alveolar dead space, as measured by the equation above, depends both on the "true" alveolar dead space and on the extent of the venous admixture, the P ET CO 2 / PaCO 2 ratio may be seen as a direct overall meter of the gas exchanger performance in a scale from 0 to 1. Indeed, a P ET CO 2 /PaCO 2 ratio equal to 1 represents the perfect gas exchanger, being, in this condition, the alveolar dead space and the venous admixture equal to 0. The presence of alveolar dead space and/or venous admixture at different extent would progressively decrease this ratio from the unity, reflecting the progressive deterioration of the gas exchanger in its two components, oxygenation and CO 2 removal. The aim of this study is to investigate whether the P ET CO 2 /PaCO 2 , easily measurable at the bedside, can be an adequate tool to assess the physio-anatomical condition of the gas exchanger. This study population consisted of 200 patients, studied from 2003 and 2016 in two university hospitals (Policlinico Milano, Milan, Italy and University Medical Center Göttingen, Göttingen, Germany). All patients suffered from ARDS according to the Berlin criteria [6] . The ethics committee was notified and permission to use the data was granted (Göttingen Antragsnummer 14/12/12). For each patient, the CT scans were acquired at 5, 15 and 45 cmH 2 O of airway pressure. We reported the anatomical variables derived from the CT quantitative analysis: namely, hyperinflated (− 1000/− 900 HU), well aerated (− 900/− 500 HU), poorly inflated (− 500/− 200 HU) and non-aerated (− 100/ + 100 HU) tissues [7, 8] . Recruitability was computed as the fraction of non-aerated tissue at 5 cmH 2 O minus the fraction of nonaerated tissue at 45 cmH 2 O [9] . Lung inhomogeneity was computed on a voxel-by-voxel basis, as the ratio of gas content between acinar size lung units and surrounding lung units [10] . A ratio equal to 1 would indicate perfect homogeneity, a ratio of 2 would indicate an inflation of the central lung unit double than the surrounding units. At 5 and 15 cmH 2 O of airway pressure, we collected the mechanical ventilation settings and respiratory mechanics variables (tidal volume, respiratory rate, alveolar ventilation, and respiratory system elastance), hemodynamics (systolic and diastolic arterial blood pressures, central venous pressure, heart rate, ScvO 2 and arteriovenous O 2 content difference) and gas exchange variables (P ET CO 2 , PaO 2 , PaCO 2 , PaO 2 /PaCO 2 ratio, SaO 2 , venous admixture (Q s /Q t ), physiological dead space fraction (V d /V t )). Tidal volume and FiO 2 were kept constant at these two PEEP levels. The volumetric capnography measurements were performed with COSMO (Respironics Novametrix, Wallingford, USA). The first analysis was done grouping the patients according to the their ARDS severity (mild, moderate-mild, moderate-severe, severe) [11] . An additional analysis was performed dividing the patients into four groups (~ 50 patients per group) based on the equal-count quartiles of their P ET CO 2 /PaCO 2 ratios determined during ventilation at 5 cmH 2 O of PEEP. For details regarding the calculated variables, please refer to Additional File 1. The normal distribution of the data was assessed by the Shapiro-Wilk test. Physiological, CT scan variables and P ET CO 2 /PaCO 2 ratio were compared among groups with oneway analysis of variance or Kruskal-Wallis test as appropriate. Multiple comparisons were performed with Bonferroni correction. Two tailed, p values < 0.05 were considered statistically significant. These statistical analyses were performed with R (R Foundation for Statistical Computing version 3.7). The main anthropometric and the physiological characteristics of the study population obtained at 5 cmH 2 O of PEEP are presented in Table 1 . Figure 1 , panel A shows the P ET CO 2 /PaCO 2 ratio as a function of ARDS severity. The ratio decreased linearly with increasing severity. In Fig. 2 , we report the mortality rate observed in the quartiles of P ET CO 2 /PaCO 2 ratio. Table 2 gives the quantitative CT scan variables obtained at 5 cmH 2 O PEEP stratified as quartiles of P ET CO 2 /PaCO 2 . As shown, the well-aerated tissue increased with the P ET CO 2 /PaCO 2 ratio. The poorly inflated, non-aerated tissue, the inhomogeneity index [10] and recruitability all significantly decrease throughout the P ET CO 2 /PaCO 2 quartiles. As shown in Table 3 , the P ET CO 2 /PaCO 2 ratio was strongly associated with respiratory system elastance, alveolar ventilation and VCO 2 . These variables improved when the P ET CO 2 /PaCO 2 ratio approached unity. The gas exchange variables under the same conditions are presented in Table 4 . As shown, the PaCO 2 progressively decreased with the concurrent increase of P ET CO 2 /PaCO 2 ratio, while the PaO 2 /FiO 2 ratio and saturation increased. Both venous admixture and dead space significantly decreased throughout the P ET CO2/PaCO 2 quartiles. P ET CO 2 /PaCO 2 ratio at different airway pressures Figure 3 illustrates how lung tissue aeration changed in the different P ET CO 2 /PaCO 2 ratio quartiles when airway pressure was increased from 5 to 15 and 45 cmH 2 O. The amount of non-aerated tissue decreased steadily from 5 to 45 cmH 2 O in all quartiles, while the amount of normally aerated tissue increased. In Table 5 , we report the changes of CT scan, respiratory mechanics and gas exchange variables through the quartiles of P ET CO 2 /PaCO 2 when PEEP was increased from 5 to 15 cmH 2 O. As shown, the greatest improvement of non-aerated tissue, PaO 2 and venous admixture were observed in quartile 1 of P ET CO 2 /PaCO 2 and the worst deterioration of dead space in quartile 4. In this study, we found that the P ET CO 2 /PaCO 2 ratio is strongly associated with most of the morphological and physiological characteristics of ARDS, resulting as an easy and appealing measure of the status and the performance of the lung. The physiological meaning of the P ET CO 2 /PaCO 2 ratio may be easily understood when one considers CO 2 kinetics through the anatomical space from the pulmonary capillaries to the airway opening. Figure 4 shows that, in the ideal lung, PaCO 2 is equal to PcCO 2 (venous admixture fraction = 0). Similarly, P ET CO 2 is equal to PACO 2 (alveolar dead space fraction = 0). Therefore, in this "ideal" setting the ratio of P ET CO 2 to PaCO 2 would be 1. This ratio will depart progressively from 1 in the presence of a venous admixture and/or alveolar dead space. Consequently, the P ET CO 2 /PaCO 2 ratio is a rather unspecific variable, as it is linked to both CO 2 and O 2 exchange impairment, but for the same reason it may give an immediate warning of an overall impairment of gas exchange. The potential role of monitoring the P ET CO 2 /PaCO 2 ratio in order to follow and understand the disease course is emphasized by its close association with the overall severity of ARDS and the mortality. This is not really surprising, as almost all variables characterizing the ARDS are related to the P ET CO 2 /PaCO 2 ratio. With regard to the morphological variables, the P ET CO 2 /PaCO 2 ratio is related to the extent of non-aerated and aerated tissue, the size of the baby lung as well as to the extent of recruitability. No other gas exchange variable exhibits such a large number of correlations with lung morphology. Indeed, venous admixture and physiological dead space were only related to the non-aerated Fig. 4 The PvCO 2 decreases to PcCO 2 (the capillary PCO 2 pressure) after releasing CO 2 in the alveolar space. The partial pressure of CO 2 in the alveoli (PACO 2 ) which are perfused is equal to PcCO 2 . This pressure represents the "ideal" alveolar gas, as it derives from pulmonary units which are both perfused and ventilated. This model ignores other factors possibly affecting the CO 2 dynamics, such as the CO 2 production from the inflammatory cells residing in the inflamed lung. Actually, this ideal PACO 2 may be "diluted" by the gas coming from unperfused but ventilated alveoli (alveolar dead space). The PACO 2 then becomes P ET CO 2 . In turn, the P ET CO 2 may be diluted into the gas ventilating the airways and the apparatus (anatomical dead space) becoming P ET CO 2 . It must be realized that the number of molecules of CO 2 involved are exactly the same, but their concentration (and partial pressure) depends on the progressive dilution with alveolar gases and "anatomical" gases. In normal individual, PACO 2 and P ET CO 2 differ only of 1-2 mmHg, being the alveolar dead space negligible. The PvCO 2 may also reach the arterial circulation without any modification in presence of venous admixture. In this case, PaCO 2 is the result of mixing between PcCO 2 and PvCO 2 . Greater is the venous admixture, greater is the difference between PaCO 2 (higher) and PcCO 2 . In the perfect gas exchanger, P ET CO 2 equals the PACO 2 (no alveolar dead space) and PACO 2 equals PaCO2 (no venous admixture). Therefore P ET CO 2 /PaCO 2 equals 1 tissue and to the normally aerated tissues, respectively. Therefore, the relative nonspecificity of the P ET CO 2 /PaCO 2 ratio, which reflects the overall gas exchange (both for oxygen and carbon dioxide), explains its correlation with all the morphological components of the lungs, of which some are more related to oxygen while others are more related to CO 2 exchange. On the other hand, the linkage between the P ET CO 2 / PaCO 2 ratio, alveolar dead space and venous admixture accounts for its high sensitivity in detecting an overall impairment in gas exchange. The P ET CO 2 /PaCO 2 ratio was inversely associated with respiratory system elastance and directly correlated with alveolar ventilation, while no relationship was found with hemodynamic variables. The low specificity but high sensitivity of the P ET CO 2 /PaCO 2 ratio to reflect an overall impairment of gas exchange is strikingly shown by the correlation we found with the gas exchange variables. Indeed, as shown in Table 4 , all measured or computed variables related either with oxygenation or carbon dioxide clearance were strongly associated with the P ET CO 2 /PaCO 2 ratio. Therefore, an altered P ET CO 2 /PaCO 2 ratio, as such, is associated both with the morphology and, the function of gas exchange, suggesting it as a sensitive, easily available marker, of changes in lung conditions. Interestingly, we found that the VCO 2 significantly increased throughout the quartiles. We believe that this is due to an improved alveolar ventilation, with greater elimination of carbon dioxide. Indeed, the low VCO 2 measured in quartile 1 possibly represents only a fraction of the metabolic CO 2 production which is partly retained. Increased alveolar ventilation throughout the quartiles leads to a normalization or even a higher than normal (metabolic) CO 2 clearance [12] . The P ET CO 2 /PaCO 2 ratio may be also considered to anticipate the PEEP response. The PEEP response in gas exchange is a balance between the decrease of venous admixture and increase in alveolar dead space. The venous admixture decrease could either be due to recruitment, better mechanical conditions of pulmonary units already open, or to a decrease in cardiac output, while the alveolar dead space increase may be due to an overdistention of pulmonary units relative to their perfusion. An increase in alveolar dead space would tend to reduce P ET CO 2 , while a decrease of right-to-left venous admixture would tend to reduce PaCO 2 . The P ET CO 2 /PaCO 2 ratio is related to the two variables, and its changes may reflect these physiopathological mechanisms. Moreover, we showed that patients starting with a lower P ET CO 2 /PaCO 2 ratio had a more favorable response to PEEP. The P ET CO 2 /PaCO 2 ratio is obviously related to the physiological dead space, although it may be considered a "positive variable" (greater the ratio, better the gas exchange) rather than "negative" (greater the dead space, worse the gas exchange). Indeed, any change of the P ET CO 2 /PaCO 2 ratio toward the value of 1 indicates an improvement of the whole gas exchanger condition, which may then be easily monitored after any maneuvre on the respiratory system, change of ventilator setting and pharmacological intervention. Indeed, the daily monitoring of this easy to use variable may show a progressive increase towards the unity, giving some evidence that the lung conditions are improving. In contrast, any change of this ratio towards lower values immediately indicates an overall decrease of the gas exchange performances. The P ET CO 2 /PaCO 2 ratio also helps the clinician to be more aware of the dynamics of CO 2 . Too often oxygenation represents the concern at the bedside of an ARDS patient, but it is only considering Pulmonary dead-space fraction as a risk factor for death in the acute respiratory distress syndrome Acute respiratory distress syndrome: the Berlin Definition Volumen inefficax Ideal alveolar air and the analysis of ventilation-perfusion relationships in the lungs Relationship between alveolar deadspace and arterial oxygenation in children with congenital cardiac disease Acute respiratory distress syndrome: the Berlin Definition MALUNA 1.03 ein Softwaretool zur analyse computertomographischer Schnittbilder del Lunge Pressure-volume curve of total respiratory system in acute respiratory failure. Computed tomographic scan study Lung recruitment in patients with the acute respiratory distress syndrome Lung inhomogeneity in patients with acute respiratory distress syndrome Reclassifying acute respiratory distress syndrome Mobilizing carbon dioxide stores: an experimental study Lung structure and function in different stages of severe adult respiratory distress syndrome Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We would like to thank Sartorius AG, Göttingen, Germany, for an unrestricted grant for lung injury-related research towards the Department of Anesthesiology of Göttingen University Medical Center. also PaCO 2 that one can have a more complete picture of the lung structure and function [13] . Finally, the P ET CO 2 /PaCO 2 ratio finds in its strength as an overall meter of gas exchange impairment also its weakness. Indeed, to fully understand the various components of the of the gas exchange alteration, both dead space and venous admixture must be be measured. In this study, we evaluated the P ET CO 2 /PaCO 2 ratio as a clinical tool to comprehensively evaluate the gas exchange lung function. The ratio was associated with most of the physiological variables that can be measured at the bedside and, therefore, it can represent a useful parameter for the daily monitoring of the ARDS patient. The online version contains supplementary material available at https:// doi. org/ 10. 1186/ s40635-021-00377-9.Additional file 1. Additional methods and formulas. Open Access funding enabled and organized by Projekt DEAL. Institutional. Dataset available upon reasonable request. The ethics committee was notified and permission to use the data was granted (Göttingen Antragsnummer 14/12/12). All authors have approved the manuscript. The authors have no conflict of interest to disclose.