key: cord-0014720-acaxciph authors: Ocskay, Klementina; Kanjo, Anna; Gede, Noémi; Szakács, Zsolt; Pár, Gabriella; Erőss, Bálint; Stange, Jan; Mitzner, Steffen; Hegyi, Péter; Molnár, Zsolt title: Uncertainty in the impact of liver support systems in acute-on-chronic liver failure: a systematic review and network meta-analysis date: 2021-01-18 journal: Ann Intensive Care DOI: 10.1186/s13613-020-00795-0 sha: ae0e8e0b25a5469b0faff5889c15896ee818f7eb doc_id: 14720 cord_uid: acaxciph BACKGROUND: The role of artificial and bioartificial liver support systems in acute-on-chronic liver failure (ACLF) is still controversial. We aimed to perform the first network meta-analysis comparing and ranking different liver support systems and standard medical therapy (SMT) in patients with ACLF. METHODS: The study protocol was registered with PROSPERO (CRD42020155850). A systematic search was conducted in five databases. We conducted a Bayesian network meta-analysis of randomized controlled trials assessing the effect of artificial or bioartificial liver support systems on survival in patients with ACLF. Ranking was performed by calculating the surface under cumulative ranking (SUCRA) curve values. The RoB2 tool and a modified GRADE approach were used for the assessment of the risk of bias and quality of evidence (QE). RESULTS: In the quantitative synthesis 16 trials were included, using MARS®, Prometheus®, ELAD®, plasma exchange (PE) and BioLogic-DT®. Overall (OS) and transplant-free (TFS) survival were assessed at 1 and 3 months. PE significantly improved 3-month OS compared to SMT (RR 0.74, CrI: 0.6–0.94) and ranked first on the cumulative ranking curves for both OS outcomes (SUCRA: 86% at 3 months; 77% at 1 month) and 3-month TFS (SUCRA: 87%) and second after ELAD for 1-month TFS (SUCRA: 76%). Other comparisons did not reach statistical significance. QE was moderate for PE concerning 1-month OS and both TFS outcomes. Other results were of very low certainty. CONCLUSION: PE seems to be the best currently available liver support therapy in ACLF regarding 3-month OS. Based on the low QE, randomized trials are needed to confirm our findings for already existing options and to introduce new devices. Acute-on-chronic liver failure (ACLF) is a clinical syndrome defined by the acute deterioration of chronic liver disease and the rapid development of organ failures, associated with high short-term mortality. ACLF is due to exogenous and endogenous precipitating factors called pathogen-and damage-associated molecular patterns (PAMPs and DAMPs) [1, 2] . The release of these molecules by necrosis or infection triggers an excessive inflammatory response, resulting in organ failures. Most patients developing ACLF have preexisting cirrhosis, which is in itself a hyperinflammatory state [3, 4] . Another aggravating factor is the immune paralysis described by several studies [5] [6] [7] [8] [9] , which prevents effective countermeasures against infection and makes patients prone to serious infective complications. Several therapies have been tested for the replacement of hepatic functions. So far, liver transplantation is the only curative therapy available. Survival rates are good, but availability and eligibility for transplant in ACLF differs by country [10] . In the CANONIC study, only 4.5% of ACLF patients received transplant. Reportedly, low transplant rates are due to the high prevalence of infection and organ failure. Waiting-list mortality exceeds 50% in this population [10] . The development of extracorporeal liver support systems dates back to the seventies with the aim to stabilize patients at the time of acute decompensation when transplant is not available or bridge patients to transplant [11] . At first, these devices were designed to replace only excretory functions and were based on hemoperfusion and adsorption [12] . The newer technologies combined these methods with bioreactors containing hepatocytes creating bioartificial liver support systems with the potential of synthetic activity. The Asian Pacific Association for the Study of the Liver (APASL) consensus guideline from 2019 states that "plasma exchange appears to be a promising and effective bridging therapy in patients with ACLF to liver transplant or spontaneous regeneration [1, C] " [13] . The European Association for the Study of the Liver (EASL) Clinical Practice Guidelines do not recommend liver support therapies for the treatment of ACLF, but underline the importance of further studies, because in specific subgroups ACLF seems beneficial [14] . Numerous pairwise meta-analyses of randomized controlled trials (RCTs) have been published assessing short-, middle-, and long-term survival benefit of liver support therapies with controversial results [15] [16] [17] [18] [19] [20] [21] [22] . These meta-analyses faced serious limitations, as they pooled together data from studies testing different devices, in some cases with different follow-up lengths. A network meta-analysis (NMA), on the other hand, can handle multiple interventions and rank them, if the assumption of transitivity is met [23] . To facilitate international discussion and consensus, we decided to perform the first NMA comparing all available and tested liver support systems to each other and standard medical therapy (SMT) in patients with ACLF and ranking these treatments by survival benefit. The protocol for this review was registered in the PROSPERO database under registration number CRD42020155850. There were no protocol deviations. This meta-analysis was reported according to The PRISMA Extension Statement for Reporting of Systematic Reviews Incorporating Network Meta-analyses of Health Care Interventions (PRISMA-NMA) [24] . Parallel randomized controlled trials assessing the safety and efficacy of artificial and bioartificial liver support therapies in adult patients with acute-on-chronic liver failure (ACLF) were eligible for inclusion, regardless of the current availability of the tested therapy and length of follow-up. Conference abstracts were included to reduce publication bias. Crossover studies were excluded from the analyses of survival due to concerns about the carryover effect, but were included in the systematic review. ACLF definitions used in the included RCTs were accepted, as there is a lack of international consensus regarding this matter. For the studies published before ACLF was introduced as a clinical entity, the review authors decided eligibility based on the eligibility criteria used in the study. Due to substantial heterogeneity regarding the definitions or the timing of measurements, some outcomes were included only in the qualitative synthesis. Studies with shorter or longer follow-up periods than the assessed outcomes were also included in the systematic review. The systematic search was conducted up to the 15th December 2019 in the following databases: MEDLINE (via PubMed), Embase, CENTRAL, Web of Science, and Scopus, with the search key designed based on the PICO format--("hepatic failure" OR "liver failure" OR "endstage liver disease" OR "cirrhosis" OR "alcoholic hepatitis") AND ("liver support system" OR "liver support device" OR "liver assist device" OR "artificial liver" OR "bioartificial liver" OR "extracorporeal liver" OR "albumin dialysis" OR "extracorporeal cellular therapy" OR "MARS" OR "Prometheus" OR "fractioned plasma separation and adsorption" OR "hemoadsorption") AND random*. No filters or restrictions were applied. References of included studies, citing articles, and authors' accessible publications in a search engine (Google Scholar) and ResearchGate were hand searched for further eligible publications. Data extraction was performed by two independent investigators (KO and AK) in duplicate using Endnote X9, Clarivate Analytics and Windows Excel 2016, Microsoft. In the case of discrepancies, agreement was reached by two experts (ZM or ZS). As a measure of inter-rater reliability, Cohen's kappa coefficients (κ) for the selection of abstracts and full texts were counted. Information collected from each study and additional information used are detailed in Additional file 1. The risk of bias assessment was conducted in duplicate using Version 2 of the Cochrane risk-of-bias tool for randomized trials (RoB 2) for overall and transplant-free survival separately [25] . For the four outcomes assessed in the NMA, quality of evidence was assessed in duplicate according to the Grades of Recommendation, Assessment, Development and Evaluation Working Group's recommendations, using a modified GRADE approach [26] . A Bayesian method was used to perform pairwise metaanalyses and NMAs with the random effect model for overall survival (OS) and transplant-free survival (TFS). For the analysis of transplant-free survival, transplant counted as an event similar to death. In case no patient received liver transplantation, OS and TFS were identical. If available, data for the intention-to-treat population were used. We used risk ratios (RR) for dichotomous data with 95% credible intervals (95% CrI). We optimized the model and generated posterior samples using the Monte-Carlo methods running in four chains. We set at least 20,000 adaptation iterations to get convergence and 10,000 simulation iterations. Network estimates (pooled direct and indirect data) of each intervention compared to standard medical therapy and other interventions are presented in forest plots, summarized in a league table (as shown in the results section). We were unable to use the nodesplitting analysis to examine the consistency assumption because of the star-shaped configuration of the networks [27] . We ranked the interventions by their posterior probability by calculating the surface under cumulative ranking (SUCRA) curve values ranging from 0 to 100%. The higher the SUCRA value, and the closer to 100%, the higher the likelihood that a therapy is in the top rank or one of the top ranks; the closer to 0 the SUCRA value, the more likely that a therapy is in the bottom rank, or one of the bottom ranks [28] . We also provided rankograms, showing the probability of achieving certain ranks. Frequentist comparison-adjusted funnel plots were created for 1-and 3-month OS, and Egger's tests were performed to assess small-study effect. The low number of studies in the TFS analyses did not enable this method. In an additional analysis, methodology-based evaluation was performed. All calculations were performed with R (V. 3.5. The systematic search yielded 2797 records. Four additional articles were identified through manual search and from previous meta-analyses. κ for abstracts and full texts was 0.87 and 0.90, respectively, marking almost perfect agreement in both cases. One hundred three full texts were assessed for eligibility. Twenty-three articles proved to meet the eligibility criteria for the systematic review and 16 were included in the data synthesis (Fig. 1) . The main characteristics of the 23 eligible studies included in qualitative synthesis are shown in Table 1 . Of the 16 studies, enrolling 1670 patients included in the meta-analysis, 15 compared a type of artificial [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] or bioartificial [39] [40] [41] [42] [43] liver support system to standard medical therapy and one study compared MARS versus MARS plus plasma exchange [44] . The most common etiologies of underlying diseases were viral infection and alcohol. From the 1526 participants with available information on gender, 1064 were males (69.8%). ACLF definitions, eligibility criteria, baseline characteristics, and outcomes of the individual studies are reported in Table 1 . Survival was reported in most of the included studies, with greatly varying follow-up lengths. Data synthesis was feasible in four cases: 1-month (28-31 days) and 3-month (84-91 days) data were pooled for overall and transplant-free survival. The summary of the findings for these four outcomes is presented in Table 2 . Plasma exchange demonstrated a statistically significant survival benefit compared to SMT in the analysis for 3-month OS (RR 0.74; CrI 0.60 to 0.94), with 86% SUCRA, 46% probability of being the best, and 41% probability of being the second-best option from the six listed treatments (Figs. 2 and 3) . PE also ranked first on the cumulative curves in three out of four analyses: both 1-and 3-month OS and 1-month TFS (Fig. 2 , Additional file 1: Figure S3 , S7). In the analysis for 1-month TFS PE ranked second after ELAD, with 76% versus 79% SUCRA values, but had a slightly higher cumulative probability of being in the first two places than ELAD (90% versus 88%) (Additional file 1: Figure S11 ). MARS ranked second in both OS outcomes (Fig. 2 , Additional file 1: Figure S3 ) with 73% SUCRA at 1 month and 71% at 3 months. Concerning TFS, MARS ranked second last and last with SUCRA values of 27% at 1 month and 33% at 3 months (Additional file 1: Figures S7 , S11). Prometheus was included in both OS analyses and in 3-month TFS. Only MARS, PE, and their combination performed better than this device in the OS outcomes and it ranked second after PE for 3-month TFS. However, the SUCRA values and the probabilities for the first ranks are much lower than for PE (SUCRA: 40% for both OS and 51% for 3-month TFS, first rank probabilities 5% for 1-month OS, 4% for 3-month OS, and 13% for 3-month TFS, shown in Figs. 2, 3, Additional file 1: Figures S3, S4 , S7, S8). Despite ELAD therapy, the only biological device ranked first for 1-month TFS, in the analysis for 3-month TFS, it had a SUCRA of 38%, even lower than SMT (41%). BioLogic-DT was included in the OS analyses and ranked second last in both cases. SMT had the lowest probability of being the best or second-best option in all four analyses. Methodology-based analyses were also performed grouping the albumin-based (MARS and Prometheus) techniques, with very similar results (only the PE-SMT comparison for 3-month OS reaching statistical significance, Additional file 1: Figures S21 and S22 ). Wilkinson et al. [45] provided data only for 5-day survival comparing BioLogic-DT with SMT in a small number of patients. The device seemed to be effective in bridging to transplant. Hu et al. [46] has found that MARS improved the survival of patients with chronic severe hepatitis with multiorgan failure. You Altogether ten studies reported the changes in mental status, but for hepatic encephalopathy (HE) different scales and definitions were used (Additional file 1: Table S2 ). All studies reported improvement, which was statistically significant only in five cases, all using MARS therapy. Ten studies reported changes in blood ammonia levels (Additional file 1: Table S4 ). Findings are controversial for MARS. Prometheus and BioLogic-DT do not remove ammonia effectively. Changes in total bilirubin (TBIL) were reported in twenty studies (Additional file 1: Table S3 ). The results were not pooled on account of different treatment doses, measurement time points, and definitions for bilirubin reduction. Hassanein et al. rightly pointed out that the time between the last treatment session and post-treatment measurements could greatly influence this outcome [38] . They showed that a single session of MARS reduced TBIL levels significantly, but this difference decreased by the end of the 5-day treatment period. MARS, PE, MARS combined with PE, Prometheus, ELAD, and HBALSS treatments significantly reduced bilirubin levels. Krisper et al. compared MARS and Prometheus in a crossover design and reported Prometheus to be more effective in the removal of conjugated and unconjugated bilirubin. BioLogic-DT does not remove bilirubin effectively. Hassanein, Heemann, and Laleman found that both MARS and Prometheus reduced bile acid levels significantly (P < 0.001 and P < 0.001, respectively) [31, 38, 49] . Krisper et al. reported that MARS and Prometheus remove individual bile acids with different clearance rates [50] . On the other hand, Meijers et al. observed no significant reduction in bile acid levels after MARS sessions. Changes in creatinine levels were reported in 12 cases (Additional file 1: Table S5 ). Findings for MARS and Bio-Logic-DT are controversial regarding creatinine removal from the blood, and Prometheus and plasma exchange therapy do not influence creatinine levels. MARS, Prometheus, and BioLogic-DT were found to decrease blood urea nitrogen levels effectively. TNF-α levels were reduced after 6 hours of BioLogic-DT treatment (P = 0.04) as reported by Kramer et al. [32] , but only small changes were observed by Ellis et al. [37] . MARS and Prometheus treatment did not reduce TNF-α levels [34, 51] . He et al. reported significant TNF-α reduction after treatment [48] . MARS did not change IL-6, IL-8, and IL-10 levels, similarly to TNF receptors 1 and 2 [34, 51] . Higher IL-8 levels were measured in the BioLogic-DT group [37] . Levels of anti-inflammatory protein IL-1 receptor antagonist were significantly elevated for days in ELAD-treated subjects [39] . In the numbers of adverse events (AEs) and reporting protocols, an immense heterogeneity was shown; therefore, quantitative data synthesis was not carried out. All devices were evaluated to be safe, and the number of AEs was comparable to the control groups. Hassanein et al. described nine possibly treatment-related adverse events in the MARS group; however, the nature of these was not detailed [38] . Acute hemolysis developed in one patient in the ELAD group [40] and treatment was discontinued in several subjects due to adverse events not specified [39, 41, 43] . Heemann et al. compared AEs in the MARS group to patients who received dialysis and found no significant difference. Two out of the twelve patients treated with MARS had fever/sepsis possibly related to the catheter [31] . Adverse events were reported in all but four papers in general. The most frequent complications were bleeding at the site of the catheter, clotting in the apparatus, and thrombocytopenia. Hypotension was reported in patients treated with PE and Prometheus [33, 49] . The quality of evidence is shown in Table 2 (see Additional file 1: Table S1 for more detail). Quality of evidence was moderate for PE in the analysis of OS at 1 month and both TFS outcomes. All other results were of very low certainty. The results of the risk of bias assessment conducted separately for OS and TFS are shown in Additional file 1: Figures S13 and S14. Overall risk of bias was low in 50% of the studies included in the OS analyses. 33% carried moderate and 22% high risk of bias. For TFS, 22% of studies carried low, 22% moderate, and 46% high risk of bias. Extracorporeal liver support therapies have been and will remain of fundamental interest in the management of ACLF [52] . However, their benefits have been debated for long. Therefore, we conducted the first network metaanalysis focusing on patients with ACLF, assessing overall and transplant-free survival at 1 and 3 months. The analyses for OS yielded similar results, with PE ranking first and MARS second on the cumulative ranking curves in both cases. From all comparisons, only plasma exchange was associated with a statistically significant improvement, when compared to SMT in the analysis of 3-month overall survival, but with very low certainty of evidence. Other comparisons did not reach statistical significance, but SMT had very low probabilities of being the best option in all analyses. Until then, evidence on the efficacy of PE in ACLF mostly originated from cohort studies. The APASL consensus guideline recommended the use of PE in ACLF for bridging to transplantation or recovery. The EASL did not find the available evidence to be sufficient for recommending the use of any liver support therapy for the treatment of ACLF. High-volume PE was found to reduce mortality and effectively remove DAMPs, TNF-α, and IL-6 in ALF patients in an RCT [53, 54] . The role of immune dysfunction and dysregulated immune response in ACLF has recently come into focus. Both hyper-inflammation and immunosuppression play a role in acute decompensation [1, 7] . Inflammation represented by elevated inflammatory markers was previously thought to be a consequence of ongoing infection, but lately endogenous inducers were identified as underlying causes [2] . Bioartificial devices have the potential of synthetic functions and contribution to the immune response [55] . So far, only ELAD was tested in RCTs, always compared to SMT. Although ELAD did not perform well on the cumulative ranking curves, significantly higher IL-1 receptor antagonist levels were measured during ELAD therapy than in controls [39] . Based on this finding, the immunomodulatory functions of bioartificial devices should be further assessed. Several new devices are being tested in animal models of liver failure, including both artificial and bioartificial ones [56, 57] , and ongoing clinical trials are enrolling ACLF patients ( [58] , NCT03882346, NCT04051437). Other blood purification methods, such as CytoSorb ™ therapy, also seem promising [59, 60] , but they have not yet been evaluated in a randomized setting. Nevertheless, according to a recent in vitro experimental model, Cyto-Sorb hemoperfusion leads to an initially faster removal of cytokines, like TNF-α and IL-6, as well as more effective reduction of albumin-bound toxins, such as indirect bilirubin and bile acids, compared to MARS [61] . There are some strengths and several limitations to our study. This is the first NMA in this field using the latest recommendations from the Cochrane Collaboration for statistical analysis, risk of bias, and QE assessment. We evaluated OS and TFS separately, at 1 and 3 months. We did not pool in-hospital, short-term, and long-term survival data. Studies enrolling patients with hepatorenal syndrome were not excluded with the aim of including cases with poorer prognosis. This new methodology enabled the comparison and ranking of different devices and highlighted the need for international consensus on the definition of ACLF and further trials testing already existing and new devices. The absence of loops in all of the created networks limits statistical analysis in Bayesian networks and results in wider credible intervals. Transitivity could not be directly tested, but we think that the differences between the study populations do not violate the assumption of transitivity. The analyses included relatively few studies, some of them only enrolling less than 10 subjects per group, raising concerns about the beta-type error. Most importantly, due to the different definitions of ACLF used (Table 1) , patient characteristics can differ significantly among studies, resulting in a highly heterogeneous population in our study. Eligibility criteria and the ratio of viral and alcoholic etiology differs in the included studies, but all patients were diagnosed with ACLF. Differences in the study populations may explain some of the controversial results of RCTs included in this meta-analysis. Also, in some of the included studies mortality was not a primary endpoint and was reported additionally; therefore, bias arises. The recruitment period for the included trials ranges from March 1997 until February 2015, which could impose chronological bias. Variance in SMT and treatment dose also could have influenced outcomes [62] . Due to the differences in treatment dose, cut-offs and reporting protocols, data on HE, laboratory parameters, and AEs could not be analyzed quantitatively. Plasma exchange seems to have the most beneficial effect at present, but liver support devices in general had higher probabilities for the first two ranks than SMT. Choosing the best option remains in the hands of the attending physician. International consensus is needed to standardize the definition of ACLF. Further RCTs targeting carefully selected subgroups of the ACLF population, using already existing and new therapeutic methods are needed to produce high-quality evidence for guideline development. The online version contains supplementary material available at https ://doi. org/10.1186/s1361 3-020-00795 -0. Additional file 1. Information collected form each study, additional information used. Figure S1 . Geometry of the network and included studies for the analysis of 1-month overall survival. Figure S2 . League table of 1-month overall survival. Figure S3 . Cumulative ranking curves and SUCRA values for 1-month overall survival. Figure S4 . Rankograms for 1-month overall survival. Figure S5 . Geometry of the network and included studies for the analysis of 3-month transplant-free survival. Figure S6 . League table of 3-month transplant-free survival. Figure S7 . Ranking of treatments for 3-month transplant-free survival. Figure S8 . Rankograms for 3-month transplant-free survival. Figure S9 . Geometry of the network and included studies for the analysis of 1-month transplantfree survival. Figure S10 . League table of 1-month transplant-free survival. Figure S11 . Ranking of treatments for 1-month transplant-free survival. Figure S12 . Rankograms for 1-month transplant-free survival. Figure S13 . Risk of bias assessment for overall survival. Figure S14 . Risk of bias assessment for transplant-free survival. Table S1 . Quality of evidence. Table S2 . Assessment of hepatic encephalopathy in the included studies. Table S3 . Assessment of bilirubin reduction in the included studies. Table S4 . Assessment of ammonia reduction in the included studies. Table S5 . Assessment of creatinine reduction in the included studies. Figure S15 . Forrest plots for 3-month overall survival. Figure S16 . Forrest plots for 1-month overall survival. Figure S17 . Forrest plots for 3-month transplantfree survival. Figure S18 . Forrest plots for 1-month transplant-free survival. Figure S19 . Funnel plot and Egger's test for 3-month overall survival. The acute-on-chronic liver failure syndrome, or when the innate immune system goes astray The immunological roles in acute-on-chronic liver failure: an update Characteristics of systemic inflammation in hepatitis B-precipitated ACLF: Differentiate it from No-ACLF Systemic inflammation in decompensated cirrhosis: Characterization and role in acute-on-chronic liver failure Blockade of PD1 and TIM3 restores innate and adaptive immunity in patients with acute alcoholic hepatitis Patients with acute-on-chronic liver failure have increased numbers of regulatory immune cells expressing the receptor tyrosine kinase MERTK Patients with acute on chronic liver failure display & #x2018;sepsis-like' immune paralysis Longitudinal monocyte human leukocyte antigen-DR expression is a prognostic marker in critically ill patients with decompensated liver cirrhosis Immunosuppression in acutely decompensated cirrhosis is mediated by prostaglandin E2 Acute-on-chronic liver failure: Excellent outcomes after liver transplantation but high mortality on the wait list Artificial liver support systems: what is new over the last decade? Ann Intensive Care Artificial liver support based on haemoperfusion of adsorbents Acute-on-chronic liver failure: consensus recommendations of the Asian Pacific association for the study of the liver (APASL): an update European Association for the Study of the Liver. EASL Clinical Practice Guidelines for the management of patients with decompensated cirrhosis Artificial and bioartificial support systems for acute and acute-on-chronic liver failure: a systematic review Artificial and bioartificial support systems for liver failure Artificial and bioartificial liver support systems for acute and acute-on-chronic hepatic failure: a meta-analysis and metaregression Survival benefits with artificial liver support system for acute-on-chronic liver failure: a time series-based meta-analysis Extracorporeal liver support in patients with liver failure: a systematic review and meta-analysis of randomized trials Systematic review and metaanalysis of survival following extracorporeal liver support Molecular adsorbent recirculating system for acute and acute-on-chronic liver failure: a meta-analysis Meta-analysis of survival with the molecular adsorbent recirculating system for liver failure Network meta-analysis: an introduction for clinicians The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations RoB 2: a revised tool for assessing risk of bias in randomised trials Summary of findings' tables in network meta-analysis (NMA Checking consistency in mixed treatment comparison meta-analysis Approaches to interpreting and choosing the best treatments in network meta-analyses Improvement of hepatorenal syndrome with extracorporeal albumin dialysis MARS: results of a prospective, randomized, controlled clinical trial Extracorporeal albumin dialysis with the molecular adsorbent recirculating system in acute-on-chronic liver failure: the RELIEF trial Albumin dialysis in cirrhosis with superimposed acute liver injury: a prospective, controlled study A controlled study of sorbent suspension dialysis in chronic liver disease and hepatic encephalopathy Artificial liver support system improves short-and long-term outcomes of patients with HBV-associated acute-on-chronic liver failure: a single-center experience Pathophysiological effects of albumin dialysis in acute-onchronic liver failure: a randomized controlled study Effects of fractionated plasma separation and adsorption on survival in patients with acute-on-chronic liver failure Prediction value of model for end-stage liver disease scoring system on prognosis in patients with acute-onchronic hepatitis B liver failure after plasma exchange and lamivudine treatment Temporary extracorporeal liver support for severe acute alcoholic hepatitis using the BioLogic-DT Randomized controlled study of extracorporeal albumin dialysis for hepatic encephalopathy in advanced cirrhosis Extracorporeal cellular therapy (ELAD) in severe alcoholic hepatitis: a multinational, prospective, controlled, randomized trial Comparison of extracorporeal cellular therapy (ELAD ® ) vs standard of care in a randomized controlled clinical trial in treating Chinese subjects with acute-on-chronic liver failure A phase 2b study of safety & efficacy in subjects with acuteon-chronic hepatitis (AOCH) due either to acute alcoholic hepatitis or acute decompensation of cirrhosis & the use of a support system (elad ® ) a human cell-based biological liver A study investigating the effect of extracorporeal cellular therapy with C3A cells on the survival of alcoholic hepatitis designed along the guidelines of the NIAAA Safety and efficacy of the Extracorporeal Liver Assist Device (ELAD ® ) in patients with acute on chronic liver failure Randomized controlled study of plasma exchange combined with molecular adsorbent re-circulating system for the treatment of liver failure complicated with hepatic encephalopathy Hemodiabsorption in treatment of hepatic failure Therapeutic application of molecular adsorbents recirculating system (MARS) in chronic severe hepatitis patients complicated with multi organ failure Clinical study on hybrid bioartificial liver supporting system for acute on chronic liver failure patients. Zhonghua shi yan he lin chuang bing du xue za zhi Zhonghua shiyan he linchuang bingduxue zazhi Chin Chen ZQ Clinical study on the treatment of fatal hepatitis with artificial liver support system Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure Removal of bile acids by two different extracorporeal liver support systems in acute-on-chronic liver failure Effect of extracorporeal liver support by MARS and Prometheus on serum cytokines in acute-on-chronic liver failure Extracorporeal therapies in liver failure High volume plasma exchange in acute liver failure: dampening the inflammatory cascade? High-volume plasma exchange in patients with acute liver failure: an open randomised controlled trial Artificial and bioartificial liver devices: present and future Bioartificial liver support systems for acute liver failure: a systematic review and meta-analysis of the clinical and preclinical literature Peritoneal albumin dialysis as a novel approach for liver support: study in a porcine model of acute hepatic failure Extracorporeal albumin dialysis using microparticle charcoal for albumin recycling is superior to using mars macroparticle adsorbents in removing albumin bound toxins (ABT) Impact of cytokine adsorption treatment in liver failure Novel use of Cytosorb haemadsorption to provide biochemical control in liver impairment Similarities, differences, and potential synergies in the mechanism of action of albumin dialysis using the MARS albumin dialysis device and the cytosorb hemoperfusion device in the treatment of liver failure Meta-analysis of individual patient data of albumin dialysis in acute-on-chronic liver failure: focus on treatment intensity Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations The authors would like to thank Szabolcs Kiss for the methodological advice and education on network meta-analyses. KO registered the study, performed the selection, data collection, risk of bias, and quality of evidence assessment; contributed to the graphical presentation of the results; and wrote the draft of the manuscript. AK performed the selection, data collection, risk of bias, and quality of evidence assessment. NG performed the statistical analysis and contributed to the interpretation of findings. ZS provided methodological guidance and was a major contributor in writing the manuscript. GP, BE, JS, and SM provided insight from the clinical perspective and contributed to the interpretation of findings. They also corrected and shaped the manuscript. PH provided the funding and infrastructure in carrying out the study along with counsel on the interpretation and presentation of the results. ZM coordinated the work group and substantially revised the manuscript. All the authors read and approved the final manuscript. The dataset(s) supporting the conclusions of this article is(are) included within the article (and its additional file(s)). Given the nature of this study, ethic approval and consent was not required. Already published data were used. This study does not contain individual data. ZM is one of the Medical directors at CytoSorbents Europe.