key: cord-0013343-7yflvmnt authors: Scaramuzzo, Gaetano; Spinelli, Elena; Spadaro, Savino; Santini, Alessandro; Tortolani, Donatella; Dalla Corte, Francesca; Pesenti, Antonio; Volta, Carlo Alberto; Grasselli, Giacomo; Mauri, Tommaso title: Gravitational distribution of regional opening and closing pressures, hysteresis and atelectrauma in ARDS evaluated by electrical impedance tomography date: 2020-10-22 journal: Crit Care DOI: 10.1186/s13054-020-03335-1 sha: 6c8170753c7f636adc5e5cba5dc4230d42ce8ffd doc_id: 13343 cord_uid: 7yflvmnt BACKGROUND: The physiological behavior of lungs affected by the acute respiratory distress syndrome (ARDS) differs between inspiration and expiration and presents heterogeneous gravity-dependent distribution. This phenomenon, highlighted by the different distribution of opening/closing pressure and by the hysteresis of the pressure–volume curve, can be studied by CT scan, but the technique expose the patient to radiations, cannot track changes during time and is not feasible at the bedside. Electrical impedance tomography (EIT) could help in assessing at the bedside regional inspiratory and expiratory mechanical properties. We evaluated regional opening/closing pressures, hysteresis and atelectrauma during inspiratory and expiratory low-flow pressure–volume curves in ARDS using electrical impedance tomography. METHODS: Pixel-level inspiratory and expiratory PV curves (PV(pixel)) between 5 and 40 cmH(2)O were constructed integrating EIT images and airway opening pressure signal from 8 ARDS patients. The lower inflection point in the inspiratory and expiratory PV(pixel) were used to find opening (OP(pixel)) and closing (CP(pixel)) pressures. A novel atelectrauma index (AtI) was calculated as the percentage of pixels opening during the inspiratory and closing during the expiratory PV curves. The maximal hysteresis (HysMax) was calculated as the maximal difference between normalized expiratory and inspiratory PV curves. Analyses were conducted in the global, dependent and non-dependent lung regions. RESULTS: Gaussian distribution was confirmed for both global OP(pixel) (r(2) = 0.90) and global CP(pixel) (r(2) = 0.94). The two distributions were significantly different with higher values for OP(pixel) (p < 0.0001). Regional OP(pixel) and CP(pixel) distributions were Gaussian, and in the dependent lung regions, both were significantly higher than in the non-dependent ones (p < 0.001). Both AtI and the HysMax were significantly higher in the dependent regions compared to the non-dependent ones (p < 0.05 for both). CONCLUSIONS: Gravity impacts the regional distribution of opening and closing pressure, hysteresis and atelectrauma, with higher values in the dorsal lung. Regional differences between inspiratory and expiratory lung physiology are detectable at the bedside using EIT and could allow in-depth characterization of ARDS phenotypes and guide personalized ventilation settings. GRAPHIC ABSTRACT: [Image: see text] Acute respiratory distress syndrome (ARDS) is characterized by the development of bilateral acute lung inflammation and edema as a consequence of direct or indirect injury [1] . Although inflammation is diffuse, lung edema is not homogeneously distributed and its impact on the mechanical properties of each lung region depends on several factors, such as gravity [2] or distance from the pleural surface [3] . The alveolar distending pressure, i.e., the transpulmonary pressure, presents, therefore, an uneven distribution in the lungs. When transpulmonary pressure (P L ) becomes negative, terminal airways and alveoli tends to collapse. Given the regional heterogeneity of P L , the threshold at which each lung unit opens and closes (i.e., regional P L = 0 cmH 2 O) does not correspond to a univocal pressure measured at airway opening [4] . Previous studies hypothesized [5] and measured [6] how: (1) recruitment and derecruitment are distributed along the entire pressure-pressure-volume curve and depend from gravity, (2) opening pressures are higher than closing pressure and (3) every patient has unique distribution of opening and closing pressures [6] . Temporal heterogeneity of ARDS can further increase the variety of these physiological mechanisms. The pressure-volume curve (PV) of the respiratory system has been used in the last decades to describe the effect of increasing and decreasing pressure in the respiratory system in a quasi-static condition. Its shape during inspiration and expiration is different, since the pressure needed to inflate is higher than the one at which collapse happens (hysteresis), probably for the dynamic action of the surfactant layer and its role in reducing superficial tension [7] : Indeed, hysteresis is absent when water is used to expand isolated animal lungs [8] . The lower inflection point (LIP) of the inspiratory PV curve indicates the pressure for terminal airways or alveoli to open, while the LIP of the expiratory limb represents the closing pressure. Despite its sound physiological basis, the use of the PV curve built from pressure and volume measured at airway opening expresses only the average behavior of the lung and it is not able to highlight the heterogeneity of regional lung mechanics [9] . Knowing the patient's regional distribution of opening and closing pressures can help in treating physicians to set mechanical ventilation and potentially improve the comprehension of regional pathophysiology and therefore lung protection. It is well known how the cyclical opening and closing, also called atelectrauma [10, 11] , can amplify the inflammatory reaction in ARDS, being one of the main determinants of ventilator-induced lung injury (VILI). Similarly, regional hysteresis could represent a simplified method to assess potential for lung recruitment at the bedside. So far, lung CT scan was used to highlight the distribution of opening and closing pressure, but this technique is not feasible at the bedside and exposes the patients to ionizing radiations [6] . Electrical impedance tomography is a radiation-free technique which has been increasingly used in the last decade to monitor ventilation [12] [13] [14] [15] . Regional inspiratory pressure-volume curves have been previously built in ARDS patients, by integrating pressure signals and EIT images [9] . Theoretically, the integration of EIT and airway pressure signal would allow to generate the inspiratory and expiratory pressure-volume curves of different functional lung units at the bedside and determine the regional behavior of opening and closing pressures, of the magnitude of hysteresis and, finally, of the risk of atelectrauma. Consequently, our hypothesis was that we would be able to detect regional opening/closing pressures using electrical impedance tomography and evaluate their gravity-dependent regional distribution in patients affected by ARDS. Patients affected by ARDS [1] , aged ≥ 18 years, sedated and paralyzed as per clinical decision were enrolled. Exclusion criteria were: refusal to participate to the study, pregnancy, unstable hemodynamics, pneumothorax, severe chronic obstructive pulmonary disease, impossibility to correctly position the EIT belt (e.g., chest drainage, surgical wound dressings) and contraindications to EIT monitoring (e.g., pacemaker, automatic implantable cardioverter defibrillator). The ethical committee of Milan Policlinico Hospital (reference number 364_2017) approved the study, and informed consent was obtained following local regulations. At enrollment, we collected demographic and clinical data of each patient. All patients were in the supine semi-recumbent position. Pressure at airway opening (Pao) and flow (f ) were recorded and processed by a dedicated data acquisition system (Colligo System, Elekton, Milan, Italy). Volume detectable at the bedside using EIT and could allow in-depth characterization of ARDS phenotypes and guide personalized ventilation settings. Keywords: Electrical impedance tomography, Hysteresis, VILI, ARDS was calculated as flow integral. A 16-electrode silicon EIT belt was placed around the chest and connected to a dedicated monitor (PulmoVista ® 500, Dräger, Lübeck, Germany). All patients underwent a low-flow inflation/deflation maneuver using the built-in ventilator tool (HAMILTON-S1, Hamilton Medical AG, Bonaduz, Switzerland) starting from Pao = 5 cmH 2 O to Pao = 40 cmH 2 O and back to Pao = 5 cmH 2 O as previously described [9, 16] . Driving pressure (DP) was calculated as the difference between end-inspiratory pressure (plateau pressure) and end-expiratory pressure after 2-s holds before performing the PV curves at PEEP = 5 cmH 2 O and with tidal volume = 6-8 ml/kg/IBW. Airway pressure waveform and EIT images during each maneuver were synchronized offline at intervals of Pao of 2.5 cmH 2 O. The variation of impedance (ΔZ) in each pixel during the maneuver was used with the corresponding ΔPao to build pixel-level PV curves (PV pixel ) for the inspiratory (PV pixel-I ) and expiratory (PV pixel-E ) maneuver. Each PV pixel-I and PV pixel-E curve was fitted in the equation of a sigmoid [17] , and fitting was considered effective if r 2 > 0.9. The PV curves with a r 2 < 0.9 were discarded (poor fitting). For each inspiratory and expiratory PV pixel curve, the lower inflection point (LIP pixel ) was mathematically identified [9] . The Pao corresponding to the inspiratory LIP pixel was considered as opening pressure for that unit (OP pixel ), while the pressure corresponds to the expiratory LIP pixel as closing pressure (CP pixel ). If the PV pixel curve was devoid of LIP pixel , OP pixel or CP pixel was likely below the starting pressure for the PV maneuver (5 cmH 2 O). The distribution of OP pixel and CP pixel for each patient was fitted into a Gaussian equation, as previously described by Crotti et al. [6] . Then, the curve for OP pixel and CP pixel for all patients was created using the cumulative mean ± SEM at each pressure interval (2.5 cmH 2 O starting from PEEP 5 cmH 2 O). The distribution was expressed as percentage of the total pixels with valid LIP pixel , defined as: The distribution of opening/closing pressures was evaluated in the whole lung and in the dependent (ROI D ) and non-dependent (ROI ND ) regions of interest. Classically, the dependent and non-dependent regions are constructed by dividing the matrix of the EIT image into two different regions based on a fixed threshold. Since the position of the lungs can be variable, we decided to adopt a more precise method, finding the centroid of each cumulative image (entire ventilated lung) which Valid LIP pixel = ventilated pixels -(poor fitting pixels + no LIP pixels) represents the mean position of all the points in all of the coordinate directions. The two regions, the patient's dorsal (ROI D ) and ventral (ROI ND ) lung region, were therefore defined by being, respectively, below and above the calculated centroid of each cumulative EIT image. Pixels ventilated less than 10% of the maximal pixel's ∆Z were excluded from the EIT analysis. The atelectrauma index (AtI) was calculated for each patient as the percentage of pixels with both LIP pixel-I and LIP pixel-E values between 5 and 40 cmH 2 O (defined as pixels opening and closing in the following formula), and therefore, that fulfilled both the following: • Presence of OP pixel between 5 and 40 cmH 2 O • Presence of CP pixel between 5 and 40 cmH 2 O divided by the total number of pixels receiving ventilation (Valid LIP pixel + poor fitting pixels + No LIP pixels) during the inspiratory maneuver: The AtI was calculated for the global lung and for the dependent (AtI D ) and non-dependent (AtI ND ) region as the number of pixels opening during PVinsp and closing during PVexp in the global lung or in each ROI divided by the total number of pixels increasing aeration during PVinsp in the whole lung or in each ROI, respectively. The normalized maximal hysteresis (HysMAX) was calculated as the maximal difference between the expiratory and inspiratory limb of the PV curve after normalizing the variation of volume of each curve, derived from the EIT signal, between 0 and 1 (see Additional file 1: online data supplement, figure S4 ). The pressure corresponding to HysMAX was assessed in each patient and termed Pao HysMAX . The calculation of HysMAX and Pao HysMAX was performed using the EIT signal for the global lung and for the dependent and non-dependent lung regions (Additional file 1: figure S4 , online supplement). EIT data analysis was performed using MATLAB R2018b (The MathWorks, Inc., Natick, Massachusetts, USA) and GraphPad prism (GraphPad Software, La Jolla California USA, www.graph pad.com). Sample size was similar to previous physiological studies on ARDS patients [6, 18] . Data are expressed as We analyzed data from 8 patients with mild and moderate ARDS, 4 males and 4 females, aged 68 (63-75) years with a median BMI of 27 (26-28) kg/m 2 and a PaO 2 /FiO 2 of 208 (185-237). Patients' characteristics at enrollment are reported in Table 1 . By analyzing data from 8 inspiratory and 8 expiratory low-flow PV maneuvers, we obtained in total 3629 PV pixel-I and 3657 PV pixel-E . Of these, 56.5% PV pixel-I and 38.8% PV pixel-E presented LIP pixel , while 11 PV pixel-I and 7 PV pixel-E were discarded for poor fitting (r 2 < 0.9, Additional file 1: table S3). When analyzing opening and closing pressures distribution from EIT-derived normalized pixel-level pressure-volume curves in the whole lung, the normal Gaussian distribution fitted well both for OP pixel (global mean value 13.5 ± 8.0 cmH 2 O, r 2 = 0.9) and for CP pixel (global mean value 6.8 ± 5.1 cmH 2 O, r 2 = 0.94, Fig. 1 ). We confirmed that the two Gaussian distributions were significantly different, with higher values for OP pixel , since a simpler Gaussian fitting model for OP pixel and CP pixel could not improve goodness of fit (p < 0.0001, Additional file 1: table S5). However, patient-level distribution showed large variability, suggesting that average values should be interpreted cautiously and that these measures should be individualized (Fig. 2 , Additional file 1: S2). When analyzing data from the two ROIs, the Gaussian distribution of OP pixel and CP pixel differed significantly (Fig. 1 ) both in the ROI ND (mean value of OP pixel 9.1 ± 9.0 cmH 2 O; mean value of CP pixel 5.1 ± 3.8 cmH 2 O) and in the ROI D (mean value of OP pixel 16.1 ± 7.6 cmH 2 O; mean value of CP pixel 7.6 ± 4.8 cmH 2 O). Comparing OP pixel and CP pixel between ROI D and ROI ND , we found that their distribution differed significantly, with higher values in the dependent region (Fig. 3) . Median AtI in the whole population was 15.4% (13.1-25.6%) with a maximum of 32.7% and a minimum of 2.3% (Table 2) . We disclosed a significant difference in the regional value of AtI, being the latter higher in the dependent lung (p = 0.02, Table 2 ). Hysteresis measures Red pixels: pixels with inspiratory regional LIP along the inspiratory limb of the PV curve and expiratory regional LIP along the expiratory limb of the PV curve, DZ = relative change of pixel impedance. Images of tidal change during the PV maneuver, pixels ventilated > 10% of the max pixel are displayed. AtI = atelectrauma index (percentage of opening/closing pixels on total ventilated pixels) Table 2 . We found a significant difference in HysMAX and Pao HysMAX between the dependent and non-dependent lung (respectively, p = 0.02 and p = 0.008), being both HysMAX and Pao HysMAX higher in the dependent lung. HysMAX showed a significant correlation with the mean OP pixel both in the global (Rs = 0.76, p = 0.04) and in the dependent lung (Rs = 0.86, p = 0.01). Moreover, HysMAX was significantly correlated with driving pressure (Rs = 0.73, p = 0.048). In the current study, we measured regional opening and closing pressure from pixel-level PV curves obtained by electrical impedance tomography. We described how the pressure determining opening and closing of alveolar units, the intensity of atelectrauma (i.e., the magnitude of atelectrauma index) and the separation between inspiration and expiration due to hysteresis are gravity-dependent, with worse scenario for the dorsal lung. Moreover, all these measures showed large inter-patient variability, indicating the need of bedside monitoring to appreciate the patient's own regional characteristics. Ventilator-induced lung injury can worsen ARDS through several mechanisms [19] . In ARDS, lungs are characterized by increased lung weight and surfactant dysfunction, leading to heterogeneous distribution of lung edema and atelectasis [7, 20] . During tidal ventilation, if the opening pressure of a lung unit is reached, the unit will open; during expiration, when the closing pressure is surpassed, the unit will close again. As opening is associated with high stress caused by the passage of the air bubble on the epithelial cells [21] , this phenomenon of cyclic opening and closing (atelectrauma) is a main determinant of VILI. This phenomenon of cyclic opening/closing of lung units is heterogeneous. We confirmed that OP pixel and CP pixel have a Gaussian distribution, with higher values for OP. Opening and closing pressures were also higher in the dependent lung, underlying the role of gravity in the distribution of lung edema and transpulmonary pressure [22] . We disclosed values of opening pressure beyond 30 cmH 2 O, confirming that recruitment is a continuous phenomenon [23] during tidal breath insufflation [3, 5] . These findings confirm previous description obtained using the lung CT scan [6] and, more recently, EIT in ALI patients [24] . Moreover, the distribution on OP and CP differed from patient to patient (see Additional file 1: online supplement), underlying the need of individualized therapy when applying mechanical ventilation. In this context, this study supports the possibility to assess these phenomena at the bedside, avoiding transport to the radiology department and exposition to ionizing radiation. Lung hysteresis is a known phenomenon characterized by the presence of a different volume at the same pressure during inspiration and expiration [25] . Several mechanisms have been proposed to justify this behavior, including surfactant effect [8, 26] and stress relaxation. Lung hysteresis indicates that higher energy is required to open the lung that to keep it open and that the extra amount of energy is dissipated between inspiration and expiration into the system [27] . We found that also hysteresis is heterogeneous, with higher values in the dependent lung. This is probably correlated with lower initial alveolar volume and greater volume excursion in the dependent lung [28] where the major part of tidal recruitment is thought to happen and where the atelectrauma index was higher. HysMAX, moreover, showed a good correlation with mean opening pressure. All these data confirm that HysMAX during two low-flow PV maneuvers reflects the extent of alveolar opening and closing and thus the recruitability, as previously found by Demory et al. [29] and suggested by Koefoed-Nielsen et al. [30, 31] . Moreover, we found that this phenomenon happens more in the dependent lung, where the atelectrauma index showed a higher value and hysteresis was higher confirming classical view of where atelectrauma is thought to happen [12] . Minimizing VILI during mechanical ventilation can be crucial to improve the outcome of ARDS. Until now, no available mean exists to detect the risk of atelectrauma in different regions of the lung at the bedside in ARDS, since the pressure-volume curve of the respiratory system can be characterized by overlapping information in such heterogeneous diseases [9] . Positive end-expiratory pressure can counteract the tendency of dorsal lung collapse, but the mechanical information coming from the ventilator (e.g., driving pressure, stress index) contains averaged information from areas with different mechanical behaviors and therefore is not useful to highlight this phenomenon. We showed that by combining pressure/volume curves and EIT it is possible to determine opening/closing pressure at the bedside. Their distribution was highly variable between lung regions and from patient to patient (Additional file 1: figure S2 ), and therefore, by using EIT, it would be possible to furtherly individualize protective mechanical ventilation to limit regional atelectrauma, instead of using average global indexes like driving pressure. This technique, applied at the bedside, may increase the pathophysiological information conveyed by EIT. Indeed, by evaluating the percentage of lung units opening and closing one can 1) quantify the maximum risk of exposure of that specific patient to atelectrauma and 2) select a positive end-expiratory pressure that could potentially guarantee recruitment and counteract derecruitment of both the non-dependent and the dependent lung regions. Our study has several limitations: First, we started the PV maneuver at PEEP = 5 cmH 2 O and not from functional residual capacity; this was done because a reduction in PEEP below 5 cmH 2 O could expose the patients to excessive derecruitment and hypoxemia. Second, we analyzed a relatively small number of patients, none with severe ARDS. These findings must be confirmed therefore in a larger and more severe population. Third, we referred to atelectrauma as the pixels opening/closing between 5 and 40 cmH 2 O, in order to characterize the physiology of each patient. However, atelectrauma is classically defined as intratidal opening/closing of alveolar unit and the intratidal difference in pressure (Pplat/ PEEP) is usually lower that the explored one (5-40 cmH 2 O). Forth, no image registration process was used to track the moving parenchyma, as done for the analysis of terminal elements (alveolar units) in CT scan. In EIT imaging, the image is reconstructed in a 2D matrix according to the thorax dimension, and therefore, the pixel dimension varies according to inflation/deflation. This could overcome, at least partially, the problem of image registration seen in fixed pixel-size imaging techniques (e.g., CT scan). Fifth, EIT do not cover the entire lung area but only the tissue around the belt position and the EIT pixel can be characterized by an intrinsic heterogeneity that could not be highlighted by the technique. Finally, the amount of recruitment/derecruitment can be influenced dynamically by time and it could be underestimated by the quasi-static punctual evaluation of the pressure-volume relationship. Electrical impedance tomography can highlight regional opening and closing pressures at the bedside in patients affected by ARDS and therefore improve bedside understanding of patient pathophysiology. Opening pressures are higher that closing pressures and gravity impact them, as well as lung hysteresis and atelectrauma: Indeed, the dependent lung is more prone to worse physiological condition. Assessment of regional lung behavior during inspiratory and expiratory PV curves could support clinical stratification of patient severity and guide personalized mechanical ventilation settings. Supplementary information accompanies this paper at https ://doi. org/10.1186/s1305 4-020-03335 -1. Additional file 1. Supplemental tables + patient's individual regional opening/closing pressures. Acute respiratory distress syndrome: the Berlin definition Effects of superimposed tissue weight on regional compliance of injured lungs The effect of positive end-expiratory pressure on lung micromechanics assessed by synchrotron radiation computed tomography in an animal model of ARDS Transpulmonary pressure: the importance of precise definitions and limiting assumptions The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs Recruitment and derecruitment during acute respiratory failure: a clinical study Surfactant dysfunction makes lungs vulnerable to repetitive collapse and reexpansion Pressure-volume curves of air-and liquid-filled excised lungs-surface tension in situ Heterogeneity of regional inflection points from pressurevolume curves assessed by electrical impedance tomography Comparative effects of volutrauma and atelectrauma on lung inflammation in experimental acute respiratory distress syndrome Volutrauma and atelectrauma: which is worse? Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group Volumepressure curve of the respiratory system predicts effects of PEEP in ARDS: "occlusion" versus "constant flow" technique A comprehensive equation for the pulmonary pressure-volume curve Potentially harmful effects of inspiratory synchronization during pressure preset ventilation Ventilator-induced lung injury and lung mechanics Vertical gradient of regional lung inflation in adult respiratory distress syndrome Biomechanics of liquid-epithelium interactions in pulmonary airways Esophageal manometry and regional transpulmonary pressure in lung injury Regional behavior of airspaces during positive pressure reduction assessed by Synchrotron Radiation Computed Tomography Regional lung opening and closing pressures in patients with acute lung injury Role of alveolar recruitment in lung inflation: influence on pressure-volume hysteresis Hysteresis in saturated phospholipid films and its potential relevance for lung surfactant function in vivo Lung hysteresis: a morphological view Pressure-volume curves of the respiratory system Recruitability of the lung estimated by the pressure volume curve hysteresis in ARDS patients Alveolar recruitment can be predicted from airway pressure-lung volume loops: an experimental study in a porcine acute lung injury model Maximal hysteresis: a new method to set positive end-expiratory pressure in acute lung injury? Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations We thank the nursing and medical staff of the intensive care unit at Cà Granda IRCCS, Milano. Authors' contributions GS, SS and TM conceived and coordinated the study; ES and DT participated in its design and helped to draft and review the manuscript. FDC, DT and GS contributed to analysis and interpretation of data and were involved in revising the manuscript. GS and TM performed the statistical analysis and the data analysis. ES, GG, AS, AP and CAV contributed to the interpretation of data and were involved in revising the manuscript. All authors meet all authorship requirements of the International Committee of Medical Journal Editors. All authors read and approved the final manuscript. Hamilton Medical AG, Bonaduz, Switzerland, provided the ventilator to perform this study free of charge and an unrestricted research grant to the Department of Pathophysiology and Transplant, University of Milan, Italy. The funding source did not have any role in the conception, design, data collection, decision to publish and writing of the manuscript. The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request. The ethical committee of Milan Policlinico Hospital (reference number 364_2017) approved the study, and informed consent was obtained following local regulations. Not applicable. Tommaso Mauri received personal fees from Drager, Mindray, Fisher and Paykel and BBraun. The authors declare no potential conflicts of interest. Ready to submit your research Ready to submit your research ? Choose BMC and benefit from:? Choose BMC and benefit from: