key: cord-0002966-i1qcanti authors: Yang, Jing; Chen, Hao; Wang, Zhenzhong; Yu, Xianglong; Niu, Xiaoyu; Tang, Yi; Diao, Youxiang title: Development of a Quantitative Loop-Mediated Isothermal Amplification Assay for the Rapid Detection of Novel Goose Parvovirus date: 2017-12-12 journal: Front Microbiol DOI: 10.3389/fmicb.2017.02472 sha: 283604cd89c223271768c0a2fb065cba3a015b13 doc_id: 2966 cord_uid: i1qcanti An infectious disease characterized with short bills and protruding tongues has attacked to meat ducks in China since March 2015, which has caused ducks poor growth and enormous economic losses to duck industry of China. It was eventually proved to be caused by parvovirus after pathogen isolation and identification. As the genomic sequence analysis showed, this pathogen shared 90.8–94.6% of nucleotide identity with goose parvovirus (GPV), and it was called duck-origin novel goose parvovirus (N-GPV). In this study, a quantitative loop-mediated isothermal amplification (qLAMP) assay was developed for the rapid diagnosis of N-GPV. A set of four specific primers, two inner and two outer, were designed targeting at VP3 gene, which could be completed within 60 min at 65°C in water bath or on a real-time PCR instrument for quantitative analysis. Specificity test of LAMP assay showed that there was no cross-reactivity between N-GPV and other duck pathogens, and the detection limit of qLAMP assay was 1.0 × 10(2) copies/μL. The repeatability of this method was confirmed by inter-assay and intra-assay tests with variability ranging from 0.74 to 2.25%. The results have indicated that the qLAMP assay was a simple, rapid, accurate, sensitive, and specific method for detecting N-GPV, especially on field detection. Waterfowl parvovirus causes high morbidity and mortality in geese and Muscovy ducks, and mortality rate ranges from 10 to 80%. These diseases can lead to enteric symptoms, watery diarrhea, prostration, and growth retardation, thus resulting in serious economic losses to waterfowl industry (Glávits et al., 2005) . In 2015, a disease, which emerged in France and Poland in the early 1970s in mule and Muscovy ducks was first reported in Chinese mainland (Chen et al., 2015) . It mainly caused short beak, protruding tongues, fragile tibia and pteroid, and growth retardation to commercial ducks. The morbidity rate ranges from 10 to 30%, and even up to 50%, thereby resulting in enormous economic losses to duck industry of China. In order to identify the exact pathogen that caused this disease, pathogen isolation and identification and genomic sequence analysis were carried out. Isolated pathogen was detected by polymerase chain reaction (PCR) assay, and the result showed that only GPV was positive; Genomic sequence analysis showed that this new pathogen shared 90.8-94.6% of nucleotide identity with goose parvovirus (GPV). These two studies above indicated that this new pathogen shared higher homology with other GPV strains. Therefore, it was called duck-origin novel goose parvovirus (N-GPV) . In common with other waterfowl parvovirus, N-GPV was also a member of the Parvoviridae family with a single-stranded DNA genome, and has a small, nonenveloped, icosahedral capsid packaging a singlestranded DNA genome of approximately 5,100 nucleotides. There are two open reading frames (ORFs) encoding nonstructural proteins (NS), and capsid proteins (VP) (Chen et al., 2015) . Recently, with advances in virological diagnositic techniques, a novel nucleic acid amplification method-loop-mediated isothermal amplification (LAMP) has attracted intense attention, which relies on auto-cycling strand displacement DNA synthesis by the Bst DNA polymerase large fragment with high strand displacement activity and a set of specific primers that recognizes six distinct sequences in the target DNA (Notomi et al., 2000) . In addition, LAMP has been considered as a time-saving, lowcost, highly specific and sensitive method (Chotiwan et al., 2017) , which can be completed within 60 min under condition of constant temperature, and it has been established to detect GPV, Muscovy duck parvovirus (MDPV), porcine parvovirus (PPV), canine parvovirus (CPV), and others targeting at VP gene (Cho et al., 2006; Chen et al., 2009; Ji et al., 2010; JinLong et al., 2010) . Results of LAMP can be judged by either turbidity, or end-products that can be visible to naked eyes with fluorescent reagents such as SYBR Green I (Tomita et al., 2008) . Lately, a novel Eva Green-based quantitative LAMP assay has become popular (Wang et al., 2006; Lee et al., 2017) . Compared with SYBR Green I-based quantitative LAMP assay, Eva Green dye R is less inhibitory to PCR and less likely to cause nonspecific amplification (Ihrig et al., 2006) . Meanwhile, aerosol pollution of this method can be avoided due to tubes closed. After amplification, results can be analyzed by amplification curve, turbidity, or fluorescence of end-products under ultraviolet light, thus judging whether target DNA is amplified (Mori et al., 2004) . In this study, a detection method quantitative loopmediated isothermal amplification (qLAMP) for amplifying VP3 gene of N-GPV was established. Amplification curves and good linear relationship have been obtained. Specificity of this method was determined by GPV and other duckorigin viruses, such as duck plague virus, duck tembusu virus, duck hepatitis virus, duck reovirus, Muscovy duck parvovirus, and H9N2-AIV. In addition, sensitivity of qLAMP was carried out with plasmid substances after tenfold series dilutions. These test results above demonstrated that this method has advantages with strong specificity, high sensitivity, easy operated, and low cost so that is valuable and suitable for clinical application in basic level production. N-GPV used in this study was isolated from morbid ducks liver in Liaocheng city, Shandong province, China (named SDLC strain). GPV (HN strain), duck plague virus (ZB strain), duck tembusu virus (GL strain), duck hepatitis virus (LC strain), duck reovirus (HB strain), Muscovy duck parvovirus (GX strain), and duck-origin H9N2-AIV (GT strain) were preserved by the Research Institute of Poultry Disease of Shandong Agricultural University. Sixty clinical liver samples and 60 cloacal swabs were collected from dead ducks and clinical healthy ducks respectively in Shandong, Jiangsu, and Henan province of China in different large-scale duck farms. The liver samples were homogenized in dulbecco's modified eagle medium (DMEM), frozen and thawed three times, then centrifuged at 5000 × g for 15 min. The supernatant were filtered through a 0.22 µm filter, and the filtrate was inoculated into duck embryo fibroblasts (DEF) cells. The culture supernatant was harvested after 5 days post-inoculated for three passages, and detected by PCR. DNA was extracted by TIANamp Genomic DNA Kit (TIANGEN biotech, Beijing, China). RNA was extracted by MiniBEST Universal RNA Extraction Kit (TaKaRa, Dalian, China). VP3 gene of N-GPV, GPV, and MDPV were aligned by the MegAlign software, and phylogenetic tree was constructed with MEGA version 7.0 using the neighbor-joining method (Figure 1 ). The reference waterfowl parvovirus isolates are listed in Table 1 . A set of four primers and PCR primers were designed based on the VP3 gene of N-GPV using an online program (PrimerExplorer V4, http://primerexplorer.jp/elamp4.0.0/index. html) and Primer 5.0 software respectively. Primers including two inner (FIP and BIP), two outer (F3 and B3), and PCR primers are shown in Table 2 . Outer primers were used to amplify target DNA, and the amplified PCR products were purified with a gel extraction kit (Takara, Dalian, China), cloned into the pMD18-T vector (Takara, Dalian, China) and transformed into E. coli DH5α competent cells. Clones were sequenced by BGI Tech (BGI Tech, Shenzhen, China), and analyzed results. High fidelity clone was cultured and extracted plasmid with Pureplasmid Mini Kit (CWBIO, Beijing, China). Meanwhile, 1.0 × 10 7 copies/µL-1.0 × 10 2 copies/µL substances were used for constructing standard curve. The qLAMP assay was conducted in a 25 µL reaction system, which containing 1 µL FIP and BIP primers (80 µM of each), 1 µL F3 and B3 primers (10 µM of each), 2.5 µL 10 × Isothemal amplification buffer, 1.5 µL 100 mM MgSO 4 , 3.5 µL 10 mM dNTP Mix, 1.25 µL 20 × EvaGreen R dye, 1 µL Bst DNA polymerase, 1 µL target DNA, 11.5 µL nuclease-free water, and performed using 7300 Real time PCR System (Applied Biosystems, Foster City, CA, United States). Mixtures were incubated at 65 • C in water bath for 60 min, and terminated by heating at 80 • C for 20 min (followed by NEB typical LAMP protocol), or carried out on 7300 Real time PCR system followed by procedure: 60 cycles of 64 • C 10 s and 65 • C 50 s, fluorescence signals were collected at the end of 65 • C step, and the cutoff point for Tt (time threshold, a cycle indicates 1 min) value was determined as 50 by the previous reported method . Data was analyzed by SDS software program (version 1.4). The qLAMP results were also analyzed by gel electrophoresis with 2% agarose gel, and observed under UV light. The PCR assay was conducted in 20 µL reaction system, containing 10 µL 2 × Ex Taq Mix, 6 µL ddH 2 O, 1 µL forward primer, 1 µL forward primer, 1 µL reverse primer, and 2 µL DNA, and performed using PCR System (Applied Biosystems, Foster City, CA, United States). PCR conditions were as follows: 95 • C for 5 min, 30 cycles of denaturation (95 • C for 30 s), annealing (55 • C for 30 s), and extension (72 • C for 30 s), followed by a final extension at 72 • C for 10 min. Ten-fold series dilutions (10 7 -10 0 copies/µL) of standard substance were used as templates for qLAMP amplification to confirm its sensitivity. Quantitative loop-mediated isothermal amplification assay was carried out using different viruses including GPV, duck plague virus, duck tembusu virus, duck hepatitis virus, duck reovirus, Muscovy duck parvovirus, and H9N2-AIV to validate specificity of this method. Sensitivity test was performed to compare PCR and LAMP assay, and plasmid with different dilutions was used as templates for PCR detection. F3, B3 Primers for PCR amplification were shown in Table 2 . PCR results were electrophoresed in 2% TAE agarose gel and observed in the UV transilluminator. To confirm that the qLAMP detection method has good reproducibility to detect N-GPV, tenfold series dilutions of plasmid substances, from 1.0 × 10 7 copies/µL to 1.0 × 10 0 copies/µL were used. For the intra-assay test, triplicate from each dilution were tested in the same run. For the inter-assay test, samples from each dilution were tested in three independent runs. The results were evaluated by coefficient of variation. Sixty clinical liver samples and 60 cloacal swabs from dead ducks and clinical healthy ducks respectively were collected to test reliability of qLAMP, PCR assay, and virus isolation assay. To determine genetic relationship between SDLC and other GPV and MDPV strains, phylogenetic tree of VP3 genes was constructed. Phylogenetic trees based on VP3 genes showed that the SDLC strains were in the same branch with European GPV and vaccine isolates, and shared 93.4-98.9% identity with GPV isolates, while only shared 80.4-88.7% with MDPV, which indicated that evolutionary relationship of SDLC strain is closer to GPV stains, and N-GPV is a novel variant of GPV. Concentration of positive plasmid was 253.50 ng/µL, determined by DS-11 Spectrophotometer (Denovix, America), and the copy number was 7.91 × 10 10 copies/µL. The standard curve was generated by Tt values obtained from this study, and a good linear relationship was established between the log of the plasmid copy numbers (copies/µL) and the Tt values (R 2 = 0.997), with a regression line revealing an average intercept of 51.14 and an average slope of -5.2 (Figure 2) . Performed by ten-fold series dilutions (1.0 × 10 7 -1.0 × 10 0 copies/µL) of standard substance, the qLAMP method for N-GPV detection has the lowest limit of 10 2 copies, and no amplification signals were observed in negative control (NC) (Figure 3A) . In our strategy, the results of qLAMP assay could not only be evaluated by naked eyes at the endpoint with EvaGreen R fluorescent dye in the UV light ( Figure 3B ) and agarose gel electrophoresis (Figure 3C) , it could also be quantitatively monitored using the real-time PCR system during the reaction. Specificity test of qLAMP method was carried out by seven duckorigin viruses and a goose-origin virus (mentioned in virus and samples). The results showed that our assay could only detect N-GPV and GPV, while no amplification signals were detected in other viruses ( Figure 4A) . The specificity of qLAMP assay could also be confirmed by green fluorescence in the UV light (Figure 4B) , and typical ladder pattern seen in the agarose gel electrophoresis (Figure 4C ). In addition, no positive results were obtained in negative control (NC), which indicates that this qLAMP assay has a good specificity for N-GPV detection. FIGURE 2 | Standard curve of quantitative loop-mediated isothermal amplification (qLAMP) assay using tenfold series dilutions of plasmid substances in TE buffer (1.0 × 10 7 copies/µL-1.0 × 10 2 copies/µL). Frontiers in Microbiology | www.frontiersin.org In the intra-assay test, the coefficient of variation of the Tt values varied from 0.74 to 1.81%; In the inter-assay test, the coefficient of variation of the Tt values varied from 0.82 to 2.25% ( Table 3) . These results revealed that the qLAMP method has a high reproducibility and excellent stability in detecting N-GPV. Different dilution plasmids (1.0 × 10 7 -1.0 × 10 0 copies/µL) were used as templates for LAMP and PCR amplification. Results showed that the detection limit of qLAMP assay was 10 2 copies, while PCR assay was 10 4 copies, which indicated the sensitivity of LAMP method was 100 times higher than PCR method. Loop-mediated isothermal amplification, PCR, and virus isolation assay were performed on clinical samples and cloacal swabs of ducks from different regions of China. The results were shown by statistical analysis in Table 4 . The results showed that the consistency of these three methods in every sample. The sensitivity of qLAMP assay was the highest, and there was no positive amplification in negative control in qLAMP assay, PCR, and virus isolation assay. Currently, as a laboratory assay and conventional method, PCR is used most widely. However, not only does it require expensive equipments and much time, but also it has a high requirement for experiment conditions. Meanwhile, although the Taqmanbased real-time PCR assay has been established for the detection of N-GPV, it is time-consuming and costly; In addition, the detection limit (8.8 × 10 1 copies/µL) is almost the same as qLAMP assay (1.0 × 10 2 copies/µL) (Niu et al., 2016) , so the rapid, simple, reliable, and cost-efficient qLAMP assay is definitely a good choice in detecting N-GPV. Although traditional SYBR Green I-based LAMP assay is a good method with high sensitivity and specificity, adding fluorescence dye after reaction would cause aerosol pollution, thus resulting in a false positive. However, SYBR Green I would inhibit PCR amplification if added before LAMP reaction (Eischeid, 2011) . So, the novel EvaGreen-based quantitative LAMP assay has overcome these disadvantages and is more suitable for further application. This method could also be carried out in a water bath or on a real-time PCR instrument for quantitative analysis, and results can be easily observed by turbidity, fluorescence in the UV by naked eyes and agarose gel electrophoresis. This study was the first to report the EvaGreen-based LAMP assay for detecting N-GPV. Based on the data above, the detection limit of this method was as low as 1.0 × 10 2 copies/µL, especially the intra and inter-assay variations, -just 0.74-2.25% only. In addition, the specificity of this method was 100 times higher than traditional PCR assay, and was almost the same as qPCR assay. Novel goose parvovirus is newly discovered in recent years, which mainly causes ducks growth retardation and high infection rate to meat ducks, while GPV mainly causes serious death to goslings. According to the view of homology, the N-GPV strain is closer to European GPV and vaccine isolates, while separated from Asian isolates. Therefore, it is clear that N-GPV is a member of GPV-related parvovirus. N-GPV and GPV are almost indistinguishable using this method due to higher nucleotide homology, but it's also a great method for the detection of N-GPV, because these two pathogens are from different poultry. The qLAMP assay has proved to be a highly sensitive, specific, and reliable diagnostic method that can detect N-GPV in a simple, rapid, and cost-efficient way. It could be undoubtedly used as a point-of-care strategy for clinical laboratories to prevent diseases from breaking out (Notomi et al., 2015) . Conceived and designed the experiments: YD, YT, and JY. Performed the experiments: JY, HC, and ZW. Analyzed the data: JY, XY, and XN. Contributed reagents/materials/analysis tools: JY and HC. Wrote the paper: JY. Isolation and genomic characterization of a duck-origin GPV-related parvovirus from cherry valley ducklings in China Evidence for vertical transmission of novel duck-origin goose parvovirus-related parvovirus Rapid detection of porcine parvovirus DNA by sensitive loop-mediated isothermal amplification Detection of canine parvovirus in fecal samples using loop-mediated isothermal amplification Rapid and specific detection of Asian-and Africanlineage Zika viruses SYTO dyes and evagreen outperform SYBR green in real-time PCR Comparative pathological studies on domestic geese (anser anser domestica) and muscovy ducks (cairina moschata) experimentally infected with parvovirus strains of goose and muscovy duck origin Application of the DNA-specific dye evagreen for the routine quantification of DNA in microplates Molecular detection of muscovy duck parvovirus by loop-mediated isothermal amplification assay A simple and rapid method for detection of Goose Parvovirus in the field by loop-mediated isothermal amplification One-pot reverse transcriptional loop-mediated isothermal amplification (RT-LAMP) for detecting MERS-CoV Real-time turbidimetry of LAMP reaction for quantifying template DNA Development of a TaqMan-based real-time PCR assay for the detection of Novel GPV Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects Loop-mediated isothermal amplification of DNA An immunoassay-based reversetranscription loop-mediated isothermal amplification assay for the rapid detection of avian influenza H5N1 virus viremia Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products DNA quantification using evagreen and a real-time PCR instrument The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.Copyright © 2017 Yang, Chen, Wang, Yu, Niu, Tang and Diao. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.