key: cord-0002411-o1x05kni authors: Patel, Pranav; Abd El Wahed, Ahmed; Faye, Oumar; Prüger, Pauline; Kaiser, Marco; Thaloengsok, Sasikanya; Ubol, Sukathida; Sakuntabhai, Anavaj; Leparc-Goffart, Isabelle; Hufert, Frank T.; Sall, Amadou A.; Weidmann, Manfred; Niedrig, Matthias title: A Field-Deployable Reverse Transcription Recombinase Polymerase Amplification Assay for Rapid Detection of the Chikungunya Virus date: 2016-09-29 journal: PLoS Negl Trop Dis DOI: 10.1371/journal.pntd.0004953 sha: da215867201d36fa409a1f64aa89dfe75d537784 doc_id: 2411 cord_uid: o1x05kni BACKGROUND: Chikungunya virus (CHIKV) is a mosquito-borne virus currently transmitted in about 60 countries. CHIKV causes acute flu-like symptoms and in many cases prolonged musculoskeletal and joint pain. Detection of the infection is mostly done using RT-RCR or ELISA, which are not suitable for point-of-care diagnosis. METHODOLOGY/PRINCIPAL FINDINGS: In this study, a reverse transcription recombinase polymerase amplification (RT-RPA) assay for the detection of the CHIKV was developed. The assay sensitivity, specificity, and cross-reactivity were tested. CHIKV RT-RPA assay detected down to 80 genome copies/reaction in a maximum of 15 minutes. It successfully identified 18 isolates representing the three CHIKV genotypes. No cross-reactivity was detected to other alphaviruses and arboviruses except O'nyong'nyong virus, which could be differentiated by a modified RPA primer pair. Seventy-eight samples were screened both by RT-RPA and real-time RT-PCR. The diagnostic sensitivity and specificity of the CHIKV RT-RPA assay were determined at 100%. CONCLUSIONS/SIGNIFICANCE: The developed RT-RPA assay represents a promising method for the molecular detection of CHIKV at point of need. phase samples for the detection of IgM and IgG anti-CHIKV antibodies. Serological diagnosis is confirmed by direct detection of IgM anti-CHIKV antibodies or by determining a four-fold increase in CHIKV-specific antibody titers in acute and convalescent samples by ELISA, IFT or PRNT tests [15] . Since the clinical picture of CHIKV is similar to that of DENV and Zika virus, a simple and rapid molecular assay would be needed to select the best treatment approach. The recombinase polymerase amplification (RPA) assay utilizes enzymes and proteins in order to allow the amplification of the DNA at a constant temperature (38-42°C) [24] . The presence of the amplicon is detected via the exo-probe, which include an internal abasic site mimic (tetrahydrofuran, THF) flanking fluorophore and Quencher as well as pathogen-specific 30 and 15 bases at both the 5´and 3´prime ends, respectively. Upon the hybridization of the exo-probe to the complementary sequence the Exonuclease III cleaves at the THF site and the fluorescence signal is generated. RPA assay was successfully developed for the detection of DENV and YFV as well as other human and veterinary pathogens [25] [26] [27] [28] [29] [30] [31] [32] . Moreover, a mobile suitcase laboratory was established for allowing the deployment of the RPA in the field for identifying Ebola virus infected case [33] . In this study, we developed and evaluated a reverse-transcription recombinase polymerase amplification (RT-RPA) assay as potential point-of-care (POC) diagnostic tool for rapid detection of CHIKV. The RT-RPA assay was designed by targeting the non-structure protein 1 (nsP1). The sensitivity and specificity of the method was evaluated using strains of the three genotypes of CHIKV and compared to reference RT-PCR methods. Finally, the performance of the RT-RPA assay was evaluated on acute-phase serum samples for clinical diagnosis of CHIK. In total, the study included 78 patients with a history of sudden onset of fever, headache, fatigue, nausea, vomiting, rash, myalgia and severe and very painful polyarthralgia suggestive of CHIK infection. Fifty-eight plasma samples were provided by the Department of Microbiology, Faculty of Science, Mahidol University, Bangkok, Thailand (Ethical approval ID: COA. No. MU-IRB 2010/251.3108). Twenty CHIKV positive sera samples collected from patients suspected to be infected by CHIKV during routine medical examination, were provided by French National Reference Center for Arboviruses, Marseille, France. Patients had given oral consent according to the national ethical regulations. All used samples were handled anonymously. All the different CHIKV virus strains ( Viral RNA was isolated from 140 μl aliquots of cell culture supernatants or serum sample, using the QIAamp Viral Mini Kit (QIAGEN, Hilden, Germany) according to the To identify the most conserved regions in the CHIKV genome for primer and probe design of the RPA assay, we first analyzed an alignment of fifty CHIKV full genome sequences from the RNA virus database (http://bioafrica.mrc.ac.za/rnavirusdb/) using GENEIOUS [34] . The nsP1 gene region from nucleotide position 131-306 nt was chosen for final RT-RPA assay design. In total, 196 Genbank CHIKV sequences containing the conserved nsP1 region were re-aligned using GENEIOUS. Based on the alignment, two forward primers, two reverse primers and a single probe (Table 3 ) covering all known variants of CHIKV sequences were selected. In-vitro RNA was synthesized using the RiboMAX Large Scale RNA Production System-T7 (Promega, Mannheim, Germany) according to the manufacturer´s instructions and quantified using a Nanodrop ND-1000 spectrophotometer (Thermo Scientific, Dreieich, Germany). CHIKV-genomic RNA was tested and quantified by an in-house real-time RT-PCR targeting the E gene using in vitro transcribed RNA standards as described previously [35] . The realtime RT-PCR assays is a CHIKV group-specific assay and was carried out in a one-step format using an ABI 7500 real-time PCR system and the AgPath-ID One-Step RT-PCR Kit. To quantify CHIKV genomic RNA copies, ten-fold serial dilutions of the standard in vitro transcribed RNA ranging from 5 to 5 x 10 5 RNA copies/reaction were tested within the same sample run. The sensitivity of this real-time RT-PCR was determined at nine RNA copies in 95% of the cases by probit regression. Additionally, a second real-time RT-PCR assay targeting the E gene based on 149 CHIKV sequences was used [36] . It was performed using the LightCycler 480 RNA Master Hydrolysis Probes (Roche, Mannheim, Germany) on the LightCycler 2.0 and the following temperature profile: RT at 63°C for 3 min, activation at 95°C for 30 sec and 45 cycles of 2-steps PCR at 95°C for 5 sec and 60°C for 15 sec. This real-time RT-PCR had an analytical sensitivity of 39 RNA molecules detected by performing the probit analysis. The real-time RT-RPA assay was performed in 50 μl reaction volume using the TwistAmp RT exo kit (TwistDx, Cambridge, UK) which provides all enzymes and reagents necessary for the reverse transcription step and DNA amplification in lyophilized pellets according to the manufacturer's instruction. Briefly, 29.5 μl of rehydration solution were mixed with 7.2 μl of ddH 2 O, 420 nM of each primer and 210 nM of target specific RPA exo-probe. A total of 41.5 μl of this master mix was dispensed into each tube of the eight-tubes strip and 5 μl of RNA template was added to the master mix and mixed. Finally 46.5 μl of master mix/template solution was transferred to each lyophilized RPA pellet of the eight-tubes strip provided in the kit. For each sample, 3.5 μl magnesium acetate (280 mM) was added into the lid of the reaction tubes and the tubes were closed carefully. Through centrifugation of tubes, the magnesium acetate was dropped into each reaction simultaneously to trigger the RT-RPA reaction. The reaction tubes were vortexed, centrifuged and then placed in the ESE Quant Tubescanner (Qiagen Lake Constance GmbH, Stockach, Germany) for real-time monitoring of fluorescence. The reaction was performed at 39°C for 15 minutes, with brief mixing and centrifugation of reaction tubes after four minutes. The resulting amplification curves were analyzed by ESEQuant Tube Scanner software Version 1.0 and threshold values were determined by slope validation i.e. slope (mV/ min) values were compared in order to distinguish positive from negative results. A dilution range between 10 7 and 10 1 of the nsP1 RNA molecular standard was used to determine the CHIKV RPA assay sensitivity for two RPA primer pair combinations (RF+RR3 or RF2+RR2, Table 3 ). A probit regression analysis was performed on eight RPA runs of each combination using STATISTICA (StatSoft, Hamburg, Germany). Additionally, RNA extracts were prepared from 10-fold serial dilutions of two CHIKV strains culture supernatant. RNA extracts containing low viral RNA load were prepared in 5-fold serial dilution to determine the limit of detection (LOD). Aliquots of these RNA extracts were stored at -80°C until further use. The sensitivity of the RF+RR3 combination was evaluated by testing RNA extracts simultaneously on CHIKV RT-RPA and real-time RT-PCR assays in order to compare results and determine the LOD of the RT-RPA assay. Additionally a panel of 18 different CHIKV strains including strains from the current CHIKV outbreaks representing all known three genotypes: Asian, West African and Eastern/Central /South African (ECSA) ( Table 1) were tested. In total, twenty-two viruses including eleven alphaviruses, ten flaviviruses and one phlebovirus were used to determine the assay cross reactivity ( Table 2) . Twenty CHIKV positive sera and 58 plasma samples with suspected CHIKV infection were tested by real-time RT-PCR and RT-RPA assays to evaluate diagnostic specificity and For the development of the CHIKV-specific RT-RPA assay, two forward primers, two reverse primers and one RPA probe were designed in the conserved nsP1 target region. To identify the best primer combination, a total of four combinations of were tested on RNA sample of the CHIKV LR strain. Fig 1 illustrates the results of testing the primer combinations and indicates that all four primer combinations were able to amplify CHIKV RNA efficiently within a maximum of six minutes. However, the primer combination CHIKV RF/RR3 resulted in an earlier amplification starting point (after 2.7 minutes) with s higher fluorescence intensity than the other three combinations (Fig 1) . The analytical sensitivity of both the RF+RR3 and RF2+RR2 combinations were determined using the in vitro transcribed RNA standard (n = 8) (S1 Fig). The calculated sensitivity at 95% probability was 23 and 4310 RNA molecules/reaction for RF+RR3 and RF2+RR2, respectively (Fig 2) . RNA extracts of a 10-fold serial dilution of two CHIKV strains culture supernatant (LR and IN) were tested by CHIKV RT-RPA using the RF+RR3 primers and real-time PCR to determine the analytical sensitivity. Comparative data are plotted in Fig 3. The results indicated that both the RT-RPA and the real-time PCR detected RNA linearly over 5 log 10 -steps of a serial dilution of viral RNA. Similar results were also obtained with the CHIKV IN strain (S1 Table) . To determine the LOD of the RT-RPA assay more precisely, six replicates of the RNA extracts containing low viral RNA loads as determined with real-time PCR, were diluted in a 5-fold IN strain. Overall the probit detection limit in 95% of cases for real-time RT-PCR was 10 GC/ rxn, whereas the LOD of RT-RPA was 80 GC/rxn. The sensitivity of the RT-RPA assay was assessed by testing 18 CHIKV strains representing all three genotype (Table 1 ), the specificity was tested with eleven different alphaviruses, ten flaviviruses and one phlebovirus ( Table 2 ). The CHIKV RT-RPA assay utilizing RF+RR3 efficiently detected all 18 CHIKV strains and the O'nyong'nyong virus (ONNV), while RT-RPA assay using RF2+RR2 amplified only the CHIKV strains. There was no cross reactivity found to other viruses of the cross reactivity panel (Table 2 and S2 Fig) . The diagnostic sensitivity and specificity of the CHIKV RT-RPA assay was assessed with plasma samples from 58 suspect CF cases and compared to two CHIKV specific real-time RT-PCR tests during a field trial in Bangkok, Thailand. Both CHIKV real-time RT-PCR detected 36 out of 58 sample (62%) positive. The Ct values obtained by real-time RT-PCR for positive samples ranged from 20.19 to 36.02 (1.6x10 4 -1x10 8 GC/rxn). In comparison to real-time RT-PCR, RT-RPA correctly identified all 36 positive samples and did not detect the 22 negative samples with 100% sensitivity and specificity (PPV: 1, NPV: 1, Fig 4) . Additionally, we tested 20 sera from acute CHIK patients from France. All three methods efficiently detected 20 out of 20 CHIKV positive samples. CHIKV is treated symptomatically by use of painkillers and anti-inflammatory drugs. As there is no effective specific antiviral drug and currently only experimental CHIKV vaccine development. Laboratory diagnosis of CHIKV is very important for effective outbreak management including clinical management and vector control. Therefore, there is a need for a reliable, rapid and portable diagnostic method, which can be deployed in the field during outbreaks. In this study, we developed a RT-RPA assay for rapid detection of CHIKV in clinical samples, which can be easily deployed to rural health care centers or used in field investigations. We designed a highly sensitive set of RPA primers and exo-probe, which detect CHIKV down to 80 GC/rxn. This detection limit is slightly higher than the 10 GC/rxn detected by reference real-time RT-PCR methods. However, the sensitivity of RT-RPA was sufficient to detect CHIKV infection in clinical samples from Thailand and France with an overall sensitivity and specificity of 100% in comparison to real-time RT-PCR. Previous studies described high titer viraemia exceeding 10 9 GC/ml in the acute phase of CF [37, 38] . In our study of 20 CF acute samples, viral load ranged from 1.6x10 6 -1x10 10 GC/ml (1.6x10 4 -1x10 8 GC/rxn). The RT-RPA assay detected a panel of 18 different CHIKV strains of all known three genotypes. There was no cross-reactivity of the RT-RPA assay with tested common alpha-and arboviruses except for ONNV detected with the primer combination (RF+RR3), while the combination RF2+RR2 did not detect the ONNV (S2 Fig). Cross reactivity of CHIKV RT-RPA assay to ONNV could be due to 85% similarity of the genomes of ONNV to CHIKV. RT-RPA primers RF/RR3 harbour four mismatches in RF and seven mismatches in RR3 to the ONNV sequences (S3 Fig) . This seems to reflect the fact that RPA assays have been shown to amplify target genes in the presence of up to nine mismatches [25, 30] . Moreover, the position of the mismatch did not influence the amplification step as in the real-time PCR [29] . However, we chose primer pair RF/RR3 due to its faster amplification (Tt: 3.3) and highly analytical sensitivity (23 RNA copies) in comparison to the more specific primer pair RF2/RR2 (Tt: 3.7 and analytical sensitivity: 4310). If necessary, the latter can be used for the differentiation between CHIKV and ONNV e.g. when used in ONNV endemic regions of Africa whereas the former can be used in Asia, Europe and the Americas without any issue. The RT-RPA assay using RF/RR3 demonstrated a sensitivity of 100% on CHIKV samples of the recent external quality assessment (EQA) study for molecular diagnosis but also detected one sample containing ONNV. Both real-time RT-PCR tests used in this study showed no cross reactivity to ONNV which indicates superior specificity compared to commercial PCR methods tested in the EQA study, in which 46.2% showed cross reactivity to ONNV [39] . Two loop-mediated isothermal amplification (LAMP) assays for the detection of CHIKV have been published [40, 41] . The LAMP assay require at least four primers and six binding sites and results can be usually observed visually after 30-60 minutes [42] . Recent LAMP assay developments begin to show shorter run times [43] . In contrast, the RPA assay is much faster (3-15 minutes) and utilized two primers and one probe i.e. three binding sites. In addition, RPA reagents are provided in a lyophilized pellet stable at ambient temperature (25-38°C) [26, 28, 33] , which allow independence from the cooling chain. The RPA is a promising technology to perform molecular assay at point of need. Nevertheless, the RPA primer and probe design is still challenging, as dozens of primers combinations must be tested in order to select a functional one. The current RPA assay protocol requires four pipetting steps, which is still less than the real-time PCR method but further development to miniaturize the assay is required. The cost of test per sample is around 5 USD. Lowering the cost to 1 USD will maximum its use in the affected countries. The CHIKV RPA assay presented here is a promising tool for CHIKV diagnostics at the point of need. Integration into a multimer or multiplex assay for simultaneous and differential detection of CHIKV, Dengue virus and Zika virus as well as an internal positive control would improve outbreak investigations, since the three viruses induce the same clinical picture upon infection and increasingly co-circulate in many parts of the world. Furthermore, combination with a simple extraction method for allowing isolation of virus or virus-infected cells from the whole blood and simple lysis protocol will maximize its employment at low resource settings. Table. Determining the sensitivity of RT-RPA assay. Ten-fold serial dilutions of ChiKV isolates LR and In, were tested in both real-time RT-PCR and RT-RPA. (PDF) S1 Checklist. (PDF) S1 Flowchart. A diagram represents the workflow of screening clinical samples using realtime RT-PCR and RT-RPA assays. (PDF) S1 Approval. Ethical approval from the Mahidol University Institutional Review Board on the use of the samples from suspected CHIKV-infected cases. (PDF) An epidemic of virus disease in Southern Province, Tanganyika Territory Chikungunya disease. The American journal of tropical medicine and hygiene Clinical, epidemiologic, and virologic observations on disease in non-indigenous white persons. The American journal of tropical medicine and hygiene Chikungunya infection: an emerging rheumatism among travelers returned from Indian Ocean islands Differential infectivities of o'nyong-nyong and chikungunya virus isolates in Anopheles gambiae and Aedes aegypti mosquitoes. The American journal of tropical medicine and hygiene Outbreak and spread of chikungunya Changing patterns of chikungunya virus: re-emergence of a zoonotic arbovirus Infection with chikungunya virus in Italy: an outbreak in a temperate region The American journal of tropical medicine and hygiene Chikungunya outbreaks caused by African genotype, India. Emerging infectious diseases Genome-scale phylogenetic analyses of chikungunya virus reveal independent emergences of recent epidemics and various evolutionary rates Two Chikungunya isolates from the outbreak of La Reunion (Indian Ocean) exhibit different patterns of infection in the mosquito, Aedes albopictus Independent Emergence of the Cosmopolitan Asian Chikungunya Virus Zika virus in Brazil and the danger of infestation by Aedes (Stegomyia) mosquitoes. Rev Soc Bras Med Trop Laboratory diagnosis of chikungunya virus: do we really need it? Development of a sensitive real-time reverse transcriptase PCR assay with an internal control to detect and quantify chikungunya virus Rapid detection and quantification of Chikungunya virus by a one-step reverse transcription polymerase chain reaction realtime assay. The American journal of tropical medicine and hygiene Combined detection and genotyping of Chikungunya virus by a specific reverse transcription-polymerase chain reaction Establishment of one-step SYBR green-based real time-PCR assay for rapid detection and quantification of chikungunya virus infection Performance of the RealStar Chikungunya virus real-time reverse transcription-PCR kit Development of a TaqMan RT-PCR assay without RNA extraction step for the detection and quantification of African Chikungunya viruses Specific detection of chikungunya virus using a RT-PCR/ nested PCR combination Development and evaluation of SYBR Green I-based one-step real-time RT-PCR assay for detection and quantification of Chikungunya virus DNA detection using recombination proteins A portable reverse transcription recombinase polymerase amplification assay for rapid detection of foot-andmouth disease virus Recombinase Polymerase Amplification Assay for Rapid Diagnostics of Dengue Infection Reverse transcription recombinase polymerase amplification assay for the detection of middle East respiratory syndrome coronavirus Diagnostics-in-a-Suitcase: Development of a portable and rapid assay for the detection of the emerging avian influenza A (H7N9) virus A new approach for diagnosis of bovine coronavirus using a reverse transcription recombinase polymerase amplification assay Rapid Detection of HIV-1 Proviral DNA for Early Infant Diagnosis Using Recombinase Polymerase Amplification Rapid detection of Mycobacterium tuberculosis by recombinase polymerase amplification Rapid molecular assays for the detection of yellow fever virus in low-resource settings Development and deployment of a rapid recombinase polymerase amplification Ebola virus detection assay in Guinea in 2015. Euro surveillance: bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin Geneious Basic: an integrated and extendable desktop software platform for the organization and analysis of sequence data Development of ultra-sensitive diagnosis for emerging pathogens: Technische Universität Berlin Vector competence of Aedes aegypti and Aedes vittatus (Diptera: Culicidae) from Senegal and Cape Verde archipelago for West African lineages of chikungunya virus. The American journal of tropical medicine and hygiene Chikungunya virus in US travelers returning from India Chikungunya fever in travelers returning to Europe from the Indian Ocean region External quality assessment studies for laboratory performance of molecular and serological diagnosis of Chikungunya virus infection Rapid identification of Chikungunya and Dengue virus by a real-time reverse transcription-loop-mediated isothermal amplification method. The American journal of tropical medicine and hygiene Rapid and real-time detection of Chikungunya virus by reverse transcription loop-mediated isothermal amplification assay Loop-mediated isothermal amplification of DNA Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea